0% found this document useful (0 votes)
320 views

Punching Shear Reinforcement

The document provides calculations for punching shear capacity of concrete columns based on ACI 318 code. For a rectangular column with dimensions of 140 cm x 70 cm, the controlling shear capacity is 300.30 T. For a circular column with diameter of 60 cm, the controlling shear capacity is 108.30 T. Both columns have sufficient capacity for the applied ultimate forces of 93 T and 10 T respectively.

Uploaded by

Ibrahim El Shar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
320 views

Punching Shear Reinforcement

The document provides calculations for punching shear capacity of concrete columns based on ACI 318 code. For a rectangular column with dimensions of 140 cm x 70 cm, the controlling shear capacity is 300.30 T. For a circular column with diameter of 60 cm, the controlling shear capacity is 108.30 T. Both columns have sufficient capacity for the applied ultimate forces of 93 T and 10 T respectively.

Uploaded by

Ibrahim El Shar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

F'C fy

MATERAIL PROPERTIES 35 420

ACI 318 02 PUNCHING SHEAR CALCULATION Mpa Mpa CODE USED EDGE SIDE LENGTH INTERIOR SIDE bo C s VC EQ 11-33 VC EQ 11-34 VC EQ 11-35 VC CONTROLLING SHEAR REINFORCEMENT CALCULATION CONCRETE SHEAR CAPACITY MAXIMUM ALLOWED SHEAR FORCE SHEAR CARRIED BY STEEL STIRUPS SPACING Av (Total) REQUIRED b0 STIRUPS DISTANCE NEEDED

COLUMN DIMENSIONS AND PROPERTIES COLUMN GEOMETRY LENGTH 140 cm WIDTH 70 cm COLUMN DESCRIPTION INTERIOR SIDE PARALLEL TO EGDE LENGTH CORNER INTERIOR EDGE SLAB PROPERTIES SLAB THICKNESS 40 cm COVER TO STEEL CGC 4 cm EFFECTIVE DEPTH 36 cm APPLIED ULTIMATE FORCE VU 93 T SHEAR STRESS 45.80 T/m2 VU/VC 0.3097 SAFE SECTIONS

ACI 318 99 PUNCHING SHEAR CALCULATION ACI 318 02 140 70 564 2 40 0.75 FORCE (T) 300.30 341.83 300.30 300.30

cm cm cm

STRESS (T/m2) 147.90 168.36 147.90 147.90

AR REINFORCEMENT CALCULATION 300.30 450.45 -276.40 12.5 -22.85 349.33 12.49

T T T cm cm2 cm cm

F'C fy

MATERAIL PROPERTIES 40 420

ACI 318 02 PUNCHING SHEAR CALCULATION Mpa Mpa CODE USED bo C s VC EQ 11-33 VC EQ 11-34 VC EQ 11-35 VC CONTROLLING X SHEAR REINFORCEMENT CALCULATION CONCRETE SHEAR CAPACITY MAXIMUM ALLOWED SHEAR FORCE SHEAR CARRIED BY STEEL STIRUPS SPACING Av REQUIRED b0 STIRUPS DISTANCE NEEDED

COLUMN DIMENSIONS AND PROPERTIES DIAMETER 60 cm COLUMN DESCRIPTION INTERIOR CORNER INTERIOR EDGE SLAB PROPERTIES SLAB THICKNESS 30 cm COVER TO STEEL CGC 4.5 cm EFFECTIVE DEPTH 25.5 cm APPLIED ULTIMATE FORCE VU 10 T SHEAR STRESS 14.60 T/m2 VU/VC 0.09 SAFE SECTIONS

ACI 318 99 NCHING SHEAR CALCULATION ACI 318 02 268.60617 cm 1 40 0.75 FORCE (T) STRESS (T/m2) 162.45 237.17 156.96 229.16 108.30 158.11 108.30 158.11 1.00 cm R REINFORCEMENT CALCULATION 108.30 T 162.45 T -98.30 T 12.5 cm -15.30 cm2 49.60 cm -22.11 cm

You might also like