Punching Shear Reinforcement
Punching Shear Reinforcement
ACI 318 02 PUNCHING SHEAR CALCULATION Mpa Mpa CODE USED EDGE SIDE LENGTH INTERIOR SIDE bo C s VC EQ 11-33 VC EQ 11-34 VC EQ 11-35 VC CONTROLLING SHEAR REINFORCEMENT CALCULATION CONCRETE SHEAR CAPACITY MAXIMUM ALLOWED SHEAR FORCE SHEAR CARRIED BY STEEL STIRUPS SPACING Av (Total) REQUIRED b0 STIRUPS DISTANCE NEEDED
COLUMN DIMENSIONS AND PROPERTIES COLUMN GEOMETRY LENGTH 140 cm WIDTH 70 cm COLUMN DESCRIPTION INTERIOR SIDE PARALLEL TO EGDE LENGTH CORNER INTERIOR EDGE SLAB PROPERTIES SLAB THICKNESS 40 cm COVER TO STEEL CGC 4 cm EFFECTIVE DEPTH 36 cm APPLIED ULTIMATE FORCE VU 93 T SHEAR STRESS 45.80 T/m2 VU/VC 0.3097 SAFE SECTIONS
ACI 318 99 PUNCHING SHEAR CALCULATION ACI 318 02 140 70 564 2 40 0.75 FORCE (T) 300.30 341.83 300.30 300.30
cm cm cm
T T T cm cm2 cm cm
F'C fy
ACI 318 02 PUNCHING SHEAR CALCULATION Mpa Mpa CODE USED bo C s VC EQ 11-33 VC EQ 11-34 VC EQ 11-35 VC CONTROLLING X SHEAR REINFORCEMENT CALCULATION CONCRETE SHEAR CAPACITY MAXIMUM ALLOWED SHEAR FORCE SHEAR CARRIED BY STEEL STIRUPS SPACING Av REQUIRED b0 STIRUPS DISTANCE NEEDED
COLUMN DIMENSIONS AND PROPERTIES DIAMETER 60 cm COLUMN DESCRIPTION INTERIOR CORNER INTERIOR EDGE SLAB PROPERTIES SLAB THICKNESS 30 cm COVER TO STEEL CGC 4.5 cm EFFECTIVE DEPTH 25.5 cm APPLIED ULTIMATE FORCE VU 10 T SHEAR STRESS 14.60 T/m2 VU/VC 0.09 SAFE SECTIONS
ACI 318 99 NCHING SHEAR CALCULATION ACI 318 02 268.60617 cm 1 40 0.75 FORCE (T) STRESS (T/m2) 162.45 237.17 156.96 229.16 108.30 158.11 108.30 158.11 1.00 cm R REINFORCEMENT CALCULATION 108.30 T 162.45 T -98.30 T 12.5 cm -15.30 cm2 49.60 cm -22.11 cm