Heatcom Brochure
Heatcom Brochure
Simple to install Cheap to install Simple to regulate Safe to use Maintenance free
Heatcom is a leading Danish manufacturer of underoor heating. We have more than 20 years experience from production of electric underoor heating, and our products meet the highest quality requirements. Quality tested by Semko, VDE, and BEAB, Heatcom heating cables satisfy all requirements stipulated in the EN 60335-2-96 standard. Heatcom therefore provides a 15-year warranty with its heating cables.
Heating cables are probably the most effective method of heating a room. The heat is emitted over the entire floor area, considerably improving the indoor climate. The floor temperature can be set 2-3oC lower than the desired room temperature. This can generate energy savings of 10-15%. Use of an efficient thermostat can reduce the energy consumption even further, i.e. up to 25%. Power output (watt/m2) under tiles, slate, and similar It is important to lay the cables in such a way that they can respond quickly to temperature changes Depending on what the room is to be used for and how the floor is insulated, 100-150 W/sq.m will be sufficient.
Heatcom heating cable is supplied with a unique two-in-one programmable thermostat. The thermostat has both manual and programmable options, and you can decide which to use after installation. By combining the Heatcom low-profile heating cable with a Heatcom programmable thermostat you can save up to 25% energy. The Heatcom programmable thermostat meets Norwegian requirements for installation in bathrooms and wet rooms. Heatcom 3mm heating cable on drum 12W/running metre. with HC 11 TP digital programmable thermostat Item no. 38160130 38160200 38160290 38160420 38160490 38160580 38160670 38160800 38160960 38161050 38161190 38161340 38161600 38161740 38162000 38162140 Description Kit 130 HC11TP Kit 200 HC11TP Kit 290 HC11TP Kit 420 HC11TP Kit 490 HC11TP Kit 580 HC11TP Kit 670 HC11TP Kit 800 HC11TP Kit 960 HC11TP Kit 1050 HC11TP Kit 1190 HC11TP Kit 1340 HC11TP Kit 1600 HC11TP Kit 1740 HC11TP Kit 2000 HC11TP Kit 2140 HC11TP Length m 11,3 16,5 23,5 36,0 39,0 47,0 57,0 68,0 79,0 87,0 99,0 112,0 133,0 145,0 166,0 177,0 Watt. total 100 watt/m2 = cc 12 cm 150watt/m2=cc 8 cm 130 200 290 420 490 580 670 800 960 1050 1190 1340 1600 1740 2000 2140 1,3m 2,0m 2,9m
2 2 2
2 2 2
NB! Square area minus 20% gives the correct square area of heating cable. 3
Heatcom Strong 18 is a particularly robust heating cable that can be installed on reinforcing steel or nets. If the cable is to be laid in so-called ground-moist concrete. Particular care must be taken to avoid formation of air pockets around the cable. and that the concrete has adequate thermal conductivity. Please refer to the regulations. Heatcom Strong 18 can also be installed on a firm surface. and in this case HTCU fixing tape is used. The number of watts per sq.m is determined by the spacing between the cables. Heatcom Strong 18 is also suitable for concreted outdoor surfaces and can be combined with the Heatcom programmable thermostat HC11TP.
Heatcom 5.5mm reinforced heating cable 18W/running metre for laying in screed Item no. 51210110 51210165 51210220 51210275 51210330 51210390 51210460 51210550 51210690 51210760 51210940 51211160 51211440 51211830 34000025 Description Heating Cable 5,5 mm STRONG - 11,0 m Heating Cable 5,5 mm STRONG - 16,5 m Heating Cable 5,5 mm STRONG - 22,0 m Heating Cable 5,5 mm STRONG - 27,5 m Heating Cable 5,5 mm STRONG - 33,0 m Heating Cable5,5 mm STRONG - 39,0 m Heating Cable5,5 mm STRONG - 46,0 m Heating Cable 5,5 mm STRONG - 55,0 m Heating Cable 5,5 mm STRONG - 69,0 m Heating Cable 5,5 mm STRONG - 76,0 m Heating Cable 5,5 mm STRONG - 94,0 m Heating Cable 5,5 mm STRONG - 116,0 m Heating Cable 5,5 mm STRONG - 144,0 m Heating Cable 5,5 mm STRONG - 183,0 m HTCU Fixing tape 25 m 4 Watt 200 W 300 W 400 W 500 W 600 W 700 W 850 W 1000 W 1250 W 1375 W 1700 W 2100 W 2600 W 3300 W Length 11,0 m 16,5 m 22,0 m 27,5 m 33,0 m 39,0 m 46,0 m 55,0 m 69,0 m 76,0 m 94,0 m 116,0 m 144,0 m 183,0 m Ohm 262 174 131 105 87 76 62 52 42 38 31 25 20 16
AluMat for laminate and parquet - 80 W/m2 Item no. 40840010 40840015 40840020 40840025 40840030 40840035 40840040 40840045 40840050 40840060 40840070 40840080 40840090 40840100 Description AluMat - 0,5 x 2,0 m - 1,0 m AluMat - 0,5 x 3,0 m - 1,5 m AluMat - 0,5 x 4,0 m - 2,0 m AluMat - 0,5 x 5,0 m - 2,5 m AluMat - 0,5 x 6,0 m - 3,0 m AluMat - 0,5 x 7,0 m - 3,5 m AluMat - 0,5 x 8,0 m - 4,0 m AluMat - 0,5 x 9,0 m - 4,5 m AluMat - 0,5 x 10,0 m - 5,0 m AluMat - 0,5 x 12,0 m - 6,0 m AluMat - 0,5 x 14,0 m - 7,0 m AluMat - 0,5 x 16,0 m - 8,0 m AluMat - 0,5 x 18,0 m - 9,0 m AluMat - 0,5 x 20,0 m - 10,0 m Watt 80 W 120 W 160 W 200 W 240 W 280 W 320 W 360 W 400 W 480 W 560 W 640 W 720 W 800 W
Thermal blocking may occur under wooden floors i.e. the heat collects under thick carpets or furniture that rests directly on the surface. This is unfortunate and could damage the floor. A thermostat cannot prevent thermal blocking.
HC 11 TP Programmable
w oin
-o ne
HC 11TPM Manual/digital
Thermostats for underoor heating Item no. 53100018 53100019 53300600 53400041 Description. Supplied as standard with Elko frame. Options Eljo. BJ. Heat control HC 11 TP Programmable with floor and room sensor. double pole IP21 - 16 A Heat control HC 11 TPM Digital manual on/off with floor sensor. double pole IP 21 - 16 A DIN mounted thermostat for mounting in a fuse box. ETV-1991 HC 41 manual thermostat with cover Watt 3600 W 3600 W 3600 W 3600 W
Heatcom thermostats have been specifically developed for the Nordic market. HC11TP and HC11TPM satisfy all requirements for installation in bathrooms and wet rooms. The thermostats are therefore equipped with a double pole breaker and protection against condensation equivalent to IP 21. Refer to the requirements in the regulations.
Reector plates Item no. 40101030 40101060 40101045 Description Reflector plate 3 mm 500 x 1200 pack 6 m2 Reflector plate 6 mm 500 x 1200 pack 6 m2 Reflector HC Easy. 3 mm. folded plate that covers 1.22 x 8.33 =10m2
The cold end has an integral earthed Schuko plug adapted for Norwegian conditions. This installation does not have to be done by an authorised electrician. Frost Guard with thermostat for external frost protection of pipes - 13W/running metre Item no. Designation Watt 19 W 26 W 53 W 107 W 140 W 185 W 246 W 300 W 43000014 Frost Guard with thermostat- 1,4 m 43000020 Frost Guard with thermostat - 2 m 43000040 Frost Guard with thermostat - 4 m 43000080 Frost Guard with thermostat - 8 m 43000105 Frost Guard with thermostat-10,5 m 43000140 Frost Guard with thermostat - 14 m 43000185 Frost Guard with thermostat-18,5 m 43000225 Frost Guard med termostat - 22,5 m
Heatcom Plug-in self-regulating heating cable for frost protection of internal or external pipes. Approved for drinking water pipes. Self-limiting heating cable for frost protection of internal or external pipes Item no. Designation
40047002 40047004 40047006 40047008 40047010 40047012 40047014 40047016 40047019 40047022 40047025 40047000 Pipeheat 2,0 m Cable for internal installation in pipes Pipeheat 4,0m Cable for internal installation in pipes Pipeheat 6,0m Cable for internal installation in pipes Pipeheat 8,0m Cable for internal installation in pipes Pipeheat 10,0m Cable for internal installation in pipes Pipeheat 12,0m Cable for internal installation in pipes Pipeheat 14,0m Cable for internal installation in pipes Pipeheat 16,0m Cable for internal installation in pipes Pipeheat 19,0m Cable for internal installation in pipes Pipeheat 22,0m Cable for internal installation in pipes Pipeheat 25,0m Cable for internal installation in pipes Nipple for Pipeheat 1/2 - 3/4 transition
Watt
22W 44W 66W 88W 110W 132W 154W 176W 209W 242 W 275 W
To achieve the best power output. insulation must be placed around the completed installation.
Heatcom heating cables for laying in concrete. Inside or outside 25W/running metre Heatcom 7 mm heating cable is an all-round heating cable that is used where you need a higher power output per sq.m such as for snow melting or as a heating cable on poorly insulated surfaces. The cable is not intended for laying in warm asphalt. Heatcom offers a special heating cable for laying in warm asphalt that can be supplied on a drum or as a cable on mat. Lengths from 9.5m to 135m and power output from 232 W to 3410 W.
Heatcom heating cable for hardening concrete Heatcom heating cable for hardening concrete with attached CEE plug for 16 amp. The cable is supplied as standard in three lengths. 18 m/730W. 36 m/1420W. 86 m/3515W
Heatcom has exible production of products for underoor heating. Only a small selection of the frost prevention range is presented in this catalogue. Please ask for other dimensions and types that are not shown in the tables. We supply most of your oor heating and frost prevention needs.
8
Low profile heating cable 3 mm in flexible primer. Flexible primer must have a minimum thickness of 5mm.
Low profile heating cable 3 mm on insulation. Requires self-supporting layer at least 30 mm thick. The surface must be stable to avoid cracking.
q Underfloor heating located under wood floors must have a floor sensor installed. q Underfloor heating must be placed in an approved screed. For example. tile adhesive. cement/concrete. flexible filler or similar. w The screed must have a density of at least 1500kg/m3 w The screed must have a thermal conductivity of at least 1W/m K. w The screed must have a uniform quality throughout the entire area. w The screed must be cast in a layer at least 5 mm thick. The heating cables must be fully enclosed by the screed. w Air pockets must not occur and are not permitted around the heating cables and in the screed. w The screed must not insulate or contain air pockets or other insulating materials.
w If heating cables are laid on wood constructions. these must be on a stable sub-floor and the cables must be laid in such a way that any movement in the construction cannot damage the heating cables. w Care must be taken when laying heating cables. Avoid walking on the cables or damaging the cables by dropping sharp objects on the floor. Cable laid on reinforced iron must be intended for that purpose. and care must be taken when pouring concrete. w Avoid folds in the heating cables. w The cables must not cross each other. w Make sure that all cables and connections are placed well down in the screed. P Heating cables must be installed in accordance with NEK 400. Other relevant regulations relating to electric underfloor heating must also be complied with P Thermostats: Must be CE-marked and approved for the intended use. Electric underfloor heating systems must be connected to a double pole switch. If the thermostat is single pole. a double-pole switch must be positioned before the circuit. w Maximum power under wooden floors is 80-100W/m2 - 230V AC (160W/m2 - 240V AC) w Maximum permitted power per square meter is 200W 10