This document provides information on various electric underfloor heating products from Heatcom, a leading Danish manufacturer. It describes their easy to install heating mats and cables that are safe, efficient and provide energy savings. Key products include their 3mm and 5.5mm heating cables suitable for different floor types, as well as their AluMat product designed specifically for laminate and parquet floors.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views

Heatcom Brochure

This document provides information on various electric underfloor heating products from Heatcom, a leading Danish manufacturer. It describes their easy to install heating mats and cables that are safe, efficient and provide energy savings. Key products include their 3mm and 5.5mm heating cables suitable for different floor types, as well as their AluMat product designed specifically for laminate and parquet floors.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Electric underoor heating

Simple to install Cheap to install Simple to regulate Safe to use Maintenance free

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

WHY CHOOSE HEATCOM?

Heatcom is a leading Danish manufacturer of underoor heating. We have more than 20 years experience from production of electric underoor heating, and our products meet the highest quality requirements. Quality tested by Semko, VDE, and BEAB, Heatcom heating cables satisfy all requirements stipulated in the EN 60335-2-96 standard. Heatcom therefore provides a 15-year warranty with its heating cables.

Correct choice of underoor heating


Heatcom heating cables for all types of floors. Heating cables can be used under tiles, slate, stone, laminate, parquet, or embedded in the floor.

Heating cables are probably the most effective method of heating a room. The heat is emitted over the entire floor area, considerably improving the indoor climate. The floor temperature can be set 2-3oC lower than the desired room temperature. This can generate energy savings of 10-15%. Use of an efficient thermostat can reduce the energy consumption even further, i.e. up to 25%. Power output (watt/m2) under tiles, slate, and similar It is important to lay the cables in such a way that they can respond quickly to temperature changes Depending on what the room is to be used for and how the floor is insulated, 100-150 W/sq.m will be sufficient.

HEATCOM UNDERFLOOR HEATING FOR HOUSE AND HOME


Save up to 25% energy with low prole oor heating.
The Heatcom cable mat is suitable for rectangular rooms. Simple and fast to lay, it only raises the floor height by 5mm. The mat is placed in flexible primer or tile adhesive, and the cable must be completely covered. To avoid cracks and damage, the surface must be stable. Selection of Watt/sq.m depends on how well the floor is insulated. Laying Heatcom cable mats is simple. The cable mat is mounted on a dust-free surface using strong double-sided tape. The calculated heating cable area must be equivalent to about 80% of the rooms total area. In combination with the Heatcom programmable thermostat, this is an effective way to save energy.

3mm cable mat


3mm cable mat 100W/m2, width 50cm Item no. 32100150 32101550 32100250 32100350 32100450 32100550 32100650 32100700 32100850 32100900 32101050 Item no 32150150 32151550 32150250 32150230 32150280 32150350 32150450 32150470 32150550 32150650 32150680 32150850 32150890 32151050 Description Heating Mat 100 W/m - 1,1 m (0,5 x 2,1 m) Heating Mat 100 W/m - 1,4 m (0,5 x 3,0 m) Heating Mat 100 W/m - 2,0 m (0,5 x 4,0 m) Heating Mat 100 W/m - 3,0 m (0,5 x 6,20 m) Heating Mat 100 W/m - 4,1 m (0,5 x 8,20 m) Heating Mat 100 W/m - 4,9 m (0,5 x 9,80 m) Heating Mat 100 W/m - 5,8 m (0,5 x 11,60 m) Heating Mat 100 W/m - 7,0 m (0,5 x 14,0 m) Heating Mat 100 W/m - 8,3 m (0,5 x 16,65 m) Heating Mat 100 W/m - 9,0 m (0,5 x 18,0 m) Heating Mat 100 W/m - 10,2 m (0,5 x 20,60 m) Description Heating Mat 150 W/m - 1,1 m (0,5 x 2,20 m) Heating Mat 150 W/m - 1,5 m (0,5 x 3,0 m) Heating Mat 150 W/m - 2,0 m (0,5 x 4,05 m) Heating Mat 150 W/m - 2,3 m (0,5 x 4,60 m) Heating Mat 150 W/m - 2,8 m (0,5 x 5,50 m) Heating Mat 150 W/m - 3,1 m (0,5 x 6,20 m) Heating Mat 150 W/m - 3,7 m (0,5 x 7,40 m) Heating Mat 150 W/m - 4,4 m (0,5 x 8,80 m) Heating Mat 150 W/m - 5,2 m (0,5 x 10,20 m) Heating Mat 150 W/m - 6,2 m (0,5 x 12,40 m) Heating Mat 150 W/m - 6,8 m (0,5 x 13,60 m) Heating Mat 150 W/m - 7,7 m (0,5 x 15,35 m) Heating Mat 150 W/m - 8,7 m (0,5 x 17,40 m) Heating Mat 150 W/m - 10,4 m (0,5 x 20,80 m) 2 Power watt 110 W 150 W 200 W 320 W 410 W 490 W 580 W 700 W 830 W 940 W 1020 W Power watt 165 W 225 W 300 W 350 W 420 W 465 W 555 W 660 W 785 W 955 W 1020 W 1070 W 1320 W 1560 W Length m 2,1 3 4 6,2 8,2 9,8 11,6 14 16,65 18 20,4 Length m 2,2 3 4,05 4,6 5,5 6,2 7,4 8,8 10,2 12,4 13,6 15,35 17,4 20,8 Sq.m 1 1,4 2 3,0 4,1 4,9 5,8 7 8,3 9 10,2 Sq.m 1,1 1,5 2 2,3 2,8 3,1 3,7 4,4 5,2 6,2 6,8 7,7 8,7 10,4

3mm cable mat 150W/m2. width 50cm

Heatcom 3 mm heating cable on drum. 12 W/running metre


Supplied with a two-in-one programmable thermostat and installation tape.
Heatcom heating cable on drum is recommended for areas that are not rectangular and in which permanent fixtures make it difficult to lay a mat. Heatcom heating cable on drum is supplied as a set that includes double-sided installation tape and a programmable thermostat. The cable is affixed to the surface using the strong double-sided tape, and only raises the floor by 5 mm. Heatcom low profile cable is laid in flexible primer or directly in tile adhesive. It must be completely covered by the adhesive or primer. Both products must be intended for use with floor heating. The power output per sq.m can be adjusted by varying the distance (cc distance) between each cable length. Please see the table below.

Heatcom heating cable is supplied with a unique two-in-one programmable thermostat. The thermostat has both manual and programmable options, and you can decide which to use after installation. By combining the Heatcom low-profile heating cable with a Heatcom programmable thermostat you can save up to 25% energy. The Heatcom programmable thermostat meets Norwegian requirements for installation in bathrooms and wet rooms. Heatcom 3mm heating cable on drum 12W/running metre. with HC 11 TP digital programmable thermostat Item no. 38160130 38160200 38160290 38160420 38160490 38160580 38160670 38160800 38160960 38161050 38161190 38161340 38161600 38161740 38162000 38162140 Description Kit 130 HC11TP Kit 200 HC11TP Kit 290 HC11TP Kit 420 HC11TP Kit 490 HC11TP Kit 580 HC11TP Kit 670 HC11TP Kit 800 HC11TP Kit 960 HC11TP Kit 1050 HC11TP Kit 1190 HC11TP Kit 1340 HC11TP Kit 1600 HC11TP Kit 1740 HC11TP Kit 2000 HC11TP Kit 2140 HC11TP Length m 11,3 16,5 23,5 36,0 39,0 47,0 57,0 68,0 79,0 87,0 99,0 112,0 133,0 145,0 166,0 177,0 Watt. total 100 watt/m2 = cc 12 cm 150watt/m2=cc 8 cm 130 200 290 420 490 580 670 800 960 1050 1190 1340 1600 1740 2000 2140 1,3m 2,0m 2,9m
2 2 2

Ohm 407 264 183 126 109 92 80 67 55 50 44 40 33 31 27 25

0,9m 1,3m 1,9m

2 2 2

4,2m2 4,9m2 5,8m 6,7m 8,0m 9,6m 10,5m 11,9m


2 2 2 2 2 2

2,9m2 3,1m2 3,8m 4,6m 5,4m 6,3m 7,0m 7,9m


2 2 2 2 2 2

13,4m2 16m2 17,4m 20,0m 21,4m


2 2 2

9,0m2 10,6m2 11,6m 13,3m 14,1m


2 2 2

NB! Square area minus 20% gives the correct square area of heating cable. 3

Heatcom Strong 18W/running metre. 5.5mm heating cable


Supplied on a drum. thermostat not included. Heatcom Strong 18 cable. 18W/running meter is intended for laying in screed and is a reinforced class C cable with a specially robust PVC outer jacket.

Heatcom Strong 18 is a particularly robust heating cable that can be installed on reinforcing steel or nets. If the cable is to be laid in so-called ground-moist concrete. Particular care must be taken to avoid formation of air pockets around the cable. and that the concrete has adequate thermal conductivity. Please refer to the regulations. Heatcom Strong 18 can also be installed on a firm surface. and in this case HTCU fixing tape is used. The number of watts per sq.m is determined by the spacing between the cables. Heatcom Strong 18 is also suitable for concreted outdoor surfaces and can be combined with the Heatcom programmable thermostat HC11TP.

Heatcom 5.5mm reinforced heating cable 18W/running metre for laying in screed Item no. 51210110 51210165 51210220 51210275 51210330 51210390 51210460 51210550 51210690 51210760 51210940 51211160 51211440 51211830 34000025 Description Heating Cable 5,5 mm STRONG - 11,0 m Heating Cable 5,5 mm STRONG - 16,5 m Heating Cable 5,5 mm STRONG - 22,0 m Heating Cable 5,5 mm STRONG - 27,5 m Heating Cable 5,5 mm STRONG - 33,0 m Heating Cable5,5 mm STRONG - 39,0 m Heating Cable5,5 mm STRONG - 46,0 m Heating Cable 5,5 mm STRONG - 55,0 m Heating Cable 5,5 mm STRONG - 69,0 m Heating Cable 5,5 mm STRONG - 76,0 m Heating Cable 5,5 mm STRONG - 94,0 m Heating Cable 5,5 mm STRONG - 116,0 m Heating Cable 5,5 mm STRONG - 144,0 m Heating Cable 5,5 mm STRONG - 183,0 m HTCU Fixing tape 25 m 4 Watt 200 W 300 W 400 W 500 W 600 W 700 W 850 W 1000 W 1250 W 1375 W 1700 W 2100 W 2600 W 3300 W Length 11,0 m 16,5 m 22,0 m 27,5 m 33,0 m 39,0 m 46,0 m 55,0 m 69,0 m 76,0 m 94,0 m 116,0 m 144,0 m 183,0 m Ohm 262 174 131 105 87 76 62 52 42 38 31 25 20 16

Heatcom AluMat oor heating for laminate and parquet 80 Watt/m2


Heatcom Alumat. glass-bre reinforced aluminium foil with earthed heating cable. Approved by Semko.
AluMat gives a floor rise of only 2-3mm and can be laid directly below laminate or parquet. We recommend laying AluMat on a 3mm Heatcom reflector plate. With a power output of 80 watt/sq.m. it can be used as the primary heating source in the room. In older houses. heat loss can be around 50-55 Watt/sq.m. A power output lower than 70-80 W/m2 may result in inadequate heating, and supplementary heating may be necessary. To ensure good heat radiation without damage to the wood floor. parquet manufacturers recommend that the floor temperature should not exceed +27oC. A higher temperature could damage the parquet. It is therefore a requirement that underfloor heating for a wood floor is connected to a thermostat with maximum temperature limited to 27oC. The Heatcom thermostat type HC11TP has an integral temperature restrictor of +27oC and can therefore be recommended for use with underfloor heating for wooden floors.

AluMat for laminate and parquet - 80 W/m2 Item no. 40840010 40840015 40840020 40840025 40840030 40840035 40840040 40840045 40840050 40840060 40840070 40840080 40840090 40840100 Description AluMat - 0,5 x 2,0 m - 1,0 m AluMat - 0,5 x 3,0 m - 1,5 m AluMat - 0,5 x 4,0 m - 2,0 m AluMat - 0,5 x 5,0 m - 2,5 m AluMat - 0,5 x 6,0 m - 3,0 m AluMat - 0,5 x 7,0 m - 3,5 m AluMat - 0,5 x 8,0 m - 4,0 m AluMat - 0,5 x 9,0 m - 4,5 m AluMat - 0,5 x 10,0 m - 5,0 m AluMat - 0,5 x 12,0 m - 6,0 m AluMat - 0,5 x 14,0 m - 7,0 m AluMat - 0,5 x 16,0 m - 8,0 m AluMat - 0,5 x 18,0 m - 9,0 m AluMat - 0,5 x 20,0 m - 10,0 m Watt 80 W 120 W 160 W 200 W 240 W 280 W 320 W 360 W 400 W 480 W 560 W 640 W 720 W 800 W

Thermal blocking may occur under wooden floors i.e. the heat collects under thick carpets or furniture that rests directly on the surface. This is unfortunate and could damage the floor. A thermostat cannot prevent thermal blocking.

Heatcom thermostats with double pole breaker and IP 21


Approved for installation in bathrooms and wet rooms.

HC 11 TP Programmable

w oin

-o ne

HC 11TPM Manual/digital

HC 41 Manual with cover

Thermostats for underoor heating Item no. 53100018 53100019 53300600 53400041 Description. Supplied as standard with Elko frame. Options Eljo. BJ. Heat control HC 11 TP Programmable with floor and room sensor. double pole IP21 - 16 A Heat control HC 11 TPM Digital manual on/off with floor sensor. double pole IP 21 - 16 A DIN mounted thermostat for mounting in a fuse box. ETV-1991 HC 41 manual thermostat with cover Watt 3600 W 3600 W 3600 W 3600 W

Heatcom thermostats have been specifically developed for the Nordic market. HC11TP and HC11TPM satisfy all requirements for installation in bathrooms and wet rooms. The thermostats are therefore equipped with a double pole breaker and protection against condensation equivalent to IP 21. Refer to the requirements in the regulations.

Heatcom reector plates.


Increases the level of insulation in the oor and reduces the noise from footsteps.
Use of Heatcom 3 mm reflector plates increases the level of insulation and considerably reduces the noise from footsteps. Heatcom reflector plates have good compressive strength. and are suitable as a component of the under-tile surface. The cables must be covered completely by flexible primer or adhesive. When using reflector plates. it is recommended that the heating cables are placed in a self-supporting reinforced screed or flexible primer with a thickness of at least 25-30mm. The underlying surface must also be stable to prevent cracks occurring in joins or tiles. Reflector plates are supplied either as whole plates 0.5 x 1.2 m. or a folded harmonica pack 1.22 x 8.33m = 10m2

Reector plates Item no. 40101030 40101060 40101045 Description Reflector plate 3 mm 500 x 1200 pack 6 m2 Reflector plate 6 mm 500 x 1200 pack 6 m2 Reflector HC Easy. 3 mm. folded plate that covers 1.22 x 8.33 =10m2

Heatcom heating cables for outdoor and indoor pipe protection


Frost Guard with thermostat The cold end is placed close to an earthed socket and the heating cable is laid alongside or wound around the pipe. Plug-in self-regulating cable

The cold end has an integral earthed Schuko plug adapted for Norwegian conditions. This installation does not have to be done by an authorised electrician. Frost Guard with thermostat for external frost protection of pipes - 13W/running metre Item no. Designation Watt 19 W 26 W 53 W 107 W 140 W 185 W 246 W 300 W 43000014 Frost Guard with thermostat- 1,4 m 43000020 Frost Guard with thermostat - 2 m 43000040 Frost Guard with thermostat - 4 m 43000080 Frost Guard with thermostat - 8 m 43000105 Frost Guard with thermostat-10,5 m 43000140 Frost Guard with thermostat - 14 m 43000185 Frost Guard with thermostat-18,5 m 43000225 Frost Guard med termostat - 22,5 m

Heatcom Plug-in self-regulating heating cable for frost protection of internal or external pipes. Approved for drinking water pipes. Self-limiting heating cable for frost protection of internal or external pipes Item no. Designation
40047002 40047004 40047006 40047008 40047010 40047012 40047014 40047016 40047019 40047022 40047025 40047000 Pipeheat 2,0 m Cable for internal installation in pipes Pipeheat 4,0m Cable for internal installation in pipes Pipeheat 6,0m Cable for internal installation in pipes Pipeheat 8,0m Cable for internal installation in pipes Pipeheat 10,0m Cable for internal installation in pipes Pipeheat 12,0m Cable for internal installation in pipes Pipeheat 14,0m Cable for internal installation in pipes Pipeheat 16,0m Cable for internal installation in pipes Pipeheat 19,0m Cable for internal installation in pipes Pipeheat 22,0m Cable for internal installation in pipes Pipeheat 25,0m Cable for internal installation in pipes Nipple for Pipeheat 1/2 - 3/4 transition

Watt
22W 44W 66W 88W 110W 132W 154W 176W 209W 242 W 275 W

To achieve the best power output. insulation must be placed around the completed installation.

Heatcom mirror heater for demisting mirrors


Self-adhesive mirror heater that can be glued to the rear of the mirror. Prevents condensation. If the area around a mirror with heater is to be tiled. room must be allowed for possible expansion of the mirror i.e. the tiles must not be placed completely adjacent to the mirror. The mirror heater is connected to the same circuit as the lights. Speilvarme for duggfrie speil Item no. 40304045 40307657 40311060 Description Dimensions - 40 x 45 cm Dimensions - 76 x 57 cm Dimensions - 110 x 60 cm 7 Watt 70 W 100 W 144 W

Heatcom heating cable Industrial range


Heatcom self-regulating heating cable Heatcom can offer a complete range of self-limiting heating cables. For frost protection of pipes, ice-free guttering, and cables with temperatures up to 240oC. Heatcom self-limiting heating cables can be supplied in cut-to-measure lengths or on a drum. The cables have the necessary certificates and comply with all international standards.

Heatcom heating cables for laying in concrete. Inside or outside 25W/running metre Heatcom 7 mm heating cable is an all-round heating cable that is used where you need a higher power output per sq.m such as for snow melting or as a heating cable on poorly insulated surfaces. The cable is not intended for laying in warm asphalt. Heatcom offers a special heating cable for laying in warm asphalt that can be supplied on a drum or as a cable on mat. Lengths from 9.5m to 135m and power output from 232 W to 3410 W.

Heatcom heating cable for hardening concrete Heatcom heating cable for hardening concrete with attached CEE plug for 16 amp. The cable is supplied as standard in three lengths. 18 m/730W. 36 m/1420W. 86 m/3515W

Heatcom has exible production of products for underoor heating. Only a small selection of the frost prevention range is presented in this catalogue. Please ask for other dimensions and types that are not shown in the tables. We supply most of your oor heating and frost prevention needs.
8

Some examples of how to build a heated oor:


Heating cables must always be placed on an even. clean and stable surface. Insulation under the heating cables considerably increases the effect. Heating cables can be placed directly on insulation and wood. but the cables must be covered with exible primer so that the heat is conducted up to the oor. The material in which the cable is placed must be self-supporting. i.e. be at least 30 mm thick. Heating cable 5.5mm in screed. May be placed on reinforcement or 5 mm reinforced net. There must be no air pockets in the screed and the heating cables must be completely covered by flexible primer/tile adhesive.

Low profile heating cable 3 mm in flexible primer. Flexible primer must have a minimum thickness of 5mm.

Flexible primer and adhesive must be intended for underfloor heating

Low profile heating cable 3 mm on insulation. Requires self-supporting layer at least 30 mm thick. The surface must be stable to avoid cracking.

Heating cables must be connected by an authorised electrician.


9

INFORMATION PRIMARILY FOR YOUR INSTALLER.!


Important instructions relating to your electric oor heating. Heatcom underfloor heating is approved in accordance with the current EN 60335-2-96 standard. The following points must be taken into consideration together with the information on electric underfloor heating. Read the following information carefully before installing the underoor heating Underfloor heating can be laid in suitable tile adhesive (ask the supplier which type of adhesive) in cement/concrete. or flexible primer (ask the supplier which type of flexible primer). Heating cables can also be laid on a wooden sub-floor. q Underfloor heating must not be installed in walls or ceilings. q Underfloor heating must be positioned at least 30 mm from electrical installations. An overview of electrical and other installations must be available before installing underfloor heating. This relates to cables and water pipes. q Underfloor heating must not be positioned next to other sources of heat such as chimneys. light sources. and hot water pipes. q The temperature of the surroundings must be at least 5oC when the underfloor heating is installed. q Wherever possible. there must be good insulation below the underfloor heating. This saves energy. q Underfloor heating must be installed on an even surface. q Underfloor heating must be connected by an authorised installer. q Underfloor heating must be connected to a ground fault circuit interrupter of max. 30mA. q If several heating cables are to be connected together to the same thermostat. they must be connected in parallel. The location of underfloor heating must be indicated in an appropriate place in the fuse box. q Thermal resistance/blocking (floor covering+carpet or similar) between the heating cables and the room must be max. 0.125 mK/W. q Typical insulation values: Floor covering of tiles or vinyl: Medium thickness floor covering of linoleum. vinyl or similar: Wood and parquet floors: Thick floors of wood fibre and carpets:

0,035 m K/W 0,040 m K/W 0,125 m K/W 0,175 m K/W

q Underfloor heating located under wood floors must have a floor sensor installed. q Underfloor heating must be placed in an approved screed. For example. tile adhesive. cement/concrete. flexible filler or similar. w The screed must have a density of at least 1500kg/m3 w The screed must have a thermal conductivity of at least 1W/m K. w The screed must have a uniform quality throughout the entire area. w The screed must be cast in a layer at least 5 mm thick. The heating cables must be fully enclosed by the screed. w Air pockets must not occur and are not permitted around the heating cables and in the screed. w The screed must not insulate or contain air pockets or other insulating materials.

w If heating cables are laid on wood constructions. these must be on a stable sub-floor and the cables must be laid in such a way that any movement in the construction cannot damage the heating cables. w Care must be taken when laying heating cables. Avoid walking on the cables or damaging the cables by dropping sharp objects on the floor. Cable laid on reinforced iron must be intended for that purpose. and care must be taken when pouring concrete. w Avoid folds in the heating cables. w The cables must not cross each other. w Make sure that all cables and connections are placed well down in the screed. P Heating cables must be installed in accordance with NEK 400. Other relevant regulations relating to electric underfloor heating must also be complied with P Thermostats: Must be CE-marked and approved for the intended use. Electric underfloor heating systems must be connected to a double pole switch. If the thermostat is single pole. a double-pole switch must be positioned before the circuit. w Maximum power under wooden floors is 80-100W/m2 - 230V AC (160W/m2 - 240V AC) w Maximum permitted power per square meter is 200W 10