0% found this document useful (0 votes)
73 views2 pages

Design Considerations in Repair of Structures

The following considerations are important for designing structural repairs: 1) The current load distribution may be different than the original design due to deterioration, so relieving loads may be required to restore the original load path. 2) Compatibility of repair materials and the original is important to account for differences in properties that could increase thermal, vibration, and long-term effects. 3) Creep and shrinkage of repair materials must be considered to prevent loss of stiffness and increased deformations over time.

Uploaded by

lavanya_prabha
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views2 pages

Design Considerations in Repair of Structures

The following considerations are important for designing structural repairs: 1) The current load distribution may be different than the original design due to deterioration, so relieving loads may be required to restore the original load path. 2) Compatibility of repair materials and the original is important to account for differences in properties that could increase thermal, vibration, and long-term effects. 3) Creep and shrinkage of repair materials must be considered to prevent loss of stiffness and increased deformations over time.

Uploaded by

lavanya_prabha
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

Design Considerations in Repair of Structures

The rehabilitated structure may be required to provide equivalent safety to that of a new structure. The rehabilitated structure is brought to current building code standards. The design codes only provide guidance, and the engineer must apply basic principles of structural mechanics and must have an understanding of material behavior to evaluate and design a structural repair, strengthening procedure, or both. Following are some important considerations for the design of repairs: Current load distribution: In a deteriorated state, a structural member or system distributes dead and live loads differently than first assumed values when the structure was new. Cracking, deteriorated concrete and corroded reinforcement changes the load path and changes in shear, moment, and a ial load distribution takes place. !ith the removal " replacement of concrete and reinforcement before and during the repair the force effects are further modified. To get the load distribution close to the original pattern, relieving of the load by #acking or other means may be required. Compatibility of materials: $ difference in physical properties of the repair and the original material of construction increases the effects of thermal changes, vibrations, and long%term creep and shrinkage effects. &ence, either the repair material must have the same properties as the original material or the structure must be designed for the e tra movements. Creep, shrinkage, or both: &igh creep or shrinkage of repair materials compared with original construction results in loss of stiffness of the repair, redistributed forces, and increased deformations. Vibration: !hen the placed repair material is in a plastic state or until adequate strength has been developed, vibration of a structure during repair of other parts can result in reduced bonding of the repair material. Water and vapor migration: !ater or vapor migration through a concrete structure can degrade a repair and its control is essential for success of the repair.

Safety: In general, the contractor is responsible for construction safety but the ma#or safety measures like the need and e tent of shoring and bracing must be decided by the engineer. Material behavior characteristics: 'ometimes the repair material may have totally different properties than the original one. The damaged steel reinforcement may be replaced by carbon fiber%reinforced polymer (CF)*+ applied to the e ternal bottom face of the beam. F)* is stronger than steel, but has a more elastic and brittle behavior. The provisions of reinforced concrete design codes are not applicable for the repaired part. The repair is carried out considering the properties of these materials to provide at least an equivalent level of safety to the original design.