La 55p
La 55p
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 A
16019
Electrical data
IPN Primary nominal current rms 50 A IPM Primary current, measuring range 0 .. 70 A R M Measuring resistance TA = 70C TA = 85C RM min RM max RM min RM max with 12 V @ 50 A max 10 100 60 95 @ 70 A max 10 50 60 1) 60 1) with 15 V @ 50 A max 50 160 135 155 @ 70 A max 50 90 135 2) 135 2) ISN Secondary nominal current rms 50 mA K N Conversion ratio 1 : 1000 VC Supply voltage ( 5 %) 12 .. 15 V IC Current consumption 10 (@ 15 V) + IS mA
Features
Closed loop (compensated) current transducer using the Hall effect Printed circuit board mounting Isolated plastic case recognized according to UL 94-V0.
Advantages
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability.
Applications
AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications.
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70C @ TA = 85C Mass Standards - 40 .. + 85 C - 40 .. + 90 C 80 85 18 g EN 50178: 1997
Application domain
Industrial.
Notes: 1) Measuring range limited to 60 A max 2) Measuring range limited to 55 A max 3) Result of the coercive field of the magnetic circuit.
090519/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions: Over voltage category OV 3 Pollution degree PD2 Non-uniform field EN 50178 dCp, dCI, Vw Single isolation Reinforced isolation Rated isolation voltage 500 V 250 V IEC 61010-1 Nominal voltage 500 V 250 V
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
Page 2/3
090519/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Front view
Connection
Top view
Left view
Mechanical characteristics
General tolerance Primary through-hole Fastening & connection of secondary Recommended PCB hole 0.2 mm 12.7 x 7 mm 3 pins 0.63 x 0.56 mm 0.9 mm
Remarks
IS is positive when IP flows in the direction of the arrow. Temperature of the primary conductor should not exceed 90C. Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us.
Page 3/3
090519/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.