0% found this document useful (0 votes)
84 views

BLF230 1 1 en

This technical data sheet summarizes a spring-return actuator for small fire and smoke dampers: - It operates on 230V AC power and provides 6/4 Nm of torque with a 95 degree rotation. - It has electrical and mechanical switches to indicate open and closed positions, and can be operated manually. - Safety features include IP54 protection, operating between -30 to 50 degrees C, and maintaining the safe position up to 75 degrees C.

Uploaded by

alinmf3
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views

BLF230 1 1 en

This technical data sheet summarizes a spring-return actuator for small fire and smoke dampers: - It operates on 230V AC power and provides 6/4 Nm of torque with a 95 degree rotation. - It has electrical and mechanical switches to indicate open and closed positions, and can be operated manually. - Safety features include IP54 protection, operating between -30 to 50 degrees C, and maintaining the safe position up to 75 degrees C.

Uploaded by

alinmf3
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical data sheet

Spring-return actuator for small fire and smoke dampers 90 in ventilation and airconditioning systems. Torque 6/4 Nm Nominal voltage AC 230 V Control: Open/close Damper rotation: 12 mm form-fit

BLF230

Technical Data
Electrical data Nominal voltage Nominal voltage range Power consumption motoring holding for wire sizing Auxiliary switch Contact rating (contacts gold plate on silver) Switching points Connecting cable motor auxiliary switch Torque motor spring-return Direction of rotation Angle of rotation Running time motor spring-return Sound power level motor spring-return Damper rotation Position indication Service life Safety Protection class Degree of protection EMC low-voltage directive Mode of operation Rated impulse voltage Control pollution degree Ambient temperature range normal duty safety duty Non-operating temperature Ambient humidity range Maintenance Dimensions / weight Dimensions Weight AC 230 V, 50/60 Hz AC 198 ... 264 V 6 W @ nominal torque 3W 7 VA / lmax. 150 mA @ 10 ms 2 x 1 SPDT 1 mA ... 3 A (0.5 A), DC 5 V ... AC 250 V 5 / 80 1 m, 2 x 0.75 mm2 (halogen-free) 1 m, 6 x 0.75 mm2 (halogen-free) Min. 6 Nm Min. 4 Nm Selected by mounting L/R Max. 95 (incl. 5 spring pretensioning) 40 ... 75 s (0 ... 6 Nm) ~20 s @ 20 ... +50C / max. 60 s @ 30C Max. 45 dB (A) ~62 dB (A) Form-fit 12 mm (10 mm with adapter supplied) Mechanical with pointer Min. 60000 safe positions II totally insulated IP54 in all mounting positions CE according to 2004/108/EC CE according to 2006/95/EC Type 1.AA.B (EN60730-1) 4 kV (EN60730-1) 3 (EN60730-1) 30 ... +50C The safe position will be attained up to max. 75C when initiated by a thermal trip 40 ... +80C EN 60730-1 Maintenance-free See Dimensions on page 2 Approx. 1680 g

Functional data

Safety notes

The actuator is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Caution: Power supply voltage! The actuator is adapted and mounted to the fire and smoke damper by the damper manufacturer. For this reason, the actuator is only supplied direct to safety damper manufacturers. The manufacturer then bears full responsibility for the proper functioning of the damper. The device may only be opened at the manufacturers site. It does not contain any parts that can be replaced or repaired by the user. The device contains electronic and electrical components and may not be disposed of with the household waste. Observe local regulations and valid laws.

www.belimo.com

T3-BLF230 en v1.1 02.2009 Subject to changes

/2

BLF230
Product features
Mode of operation

Spring-return actuator 90 , AC 230 V, 6/4 Nm

The actuator moves the damper to its normal working position while tensioning the return spring at the same time. If the power supply is interrupted, the energy stored in the spring moves the damper back to its safe position. Two microswitches with fixed settings are installed in the actuator for indicating the damper end positions. The position of the damper blade can be read off on a mechanical position indicator. Without power supply, the damper can be operated manually and fixed in any required position. Release of the locking mechanism can be achieved manually or automatically by applying the supply voltage.

Signalling

Manual operation

Accessories
Beschreibung Electrical accessories Mechanical accessories Auxiliary switch, 1 x SPDT 6 A (2.5 A), AC 250 V Auxiliary switch, 2 x SPDT 6 A (2.5 A), AC 250 V Adapter with clamp for rotary axes up to 20 mm for BF.. and BLF.. Adapter with DM18 rotary axis, L = 33 mm, for BF.. and BLF.. Adapter 12/8 mm for BF.. and BLF.. Adapter 12/11 mm for BF.. and BLF.. Bracket for SN1 and SN2 auxiliary switches for BLF.. Typ SN1 SN2 ZK-BF ZA18-BF ZA8-BF ZA11-BF ZSN-BLF

Electrical installation
Wiring diagram
Note ! Caution: Main power supply voltage! Parallel connection of several actuators possible. Power consumption must be observed! 1 2 S1 S2 S3 S4 S5 S6 N L1

<5

<80

Dimensions [mm]
Dimensional diagrams
57.6 80 57 185 155 10 6.5 25 93 120 18

/2

12.2

98

49

T3-BLF230 en v1.1 02.2009 Subject to changes