Section 7 On Cryogenics
Section 7 On Cryogenics
This document describes the principal hazards and appropriate safety procedures associated with three cryogenic liquids that are commonly used in the College: liquid N2, He and O2. The safe handling of cryogenic liquids involves understanding the unique properties of these materials and ensuring that appropriate safety precautions are taken at all times.
Physical Properties
The attached table indicates several physical properties of liquid nitrogen, helium and oxygen. These cryogenic liquids have boiling points below -180 C and are normally used at atmospheric pressure. Thus, they are constantly boiling during use. Cryogenic liquids are typically odorless and colorless when vaporized to the gaseous state. Most of them have no color as a liquid although liquid oxygen is light blue. However, the extremely cold liquid and vapor have a built in warning property as the cold boil off gases condense moisture in the air, creating a highly visible fog.
flesh sticking to cold materials, objects that are soft and pliable at room temperature, are easily broken because they become hard and brittle at extremely low temperatures and will easily fracture. Boiling and splashing Cryogenic liquids can boil or splash when added to a warm container or when inserting warm objects in the liquid. Always perform these operations slowly to minimize boiling and splashing. Oxygen enrichment Cryogenic liquids with a boiling point below that of liquid oxygen (i.e. nitrogen and helium each have boiling points lower than oxygen boi boiling point) have the ability to condense oxygen out of the air if exposed to the atmosphere. Violent reactions (e.g. rapid combustion or explosions) may occur if the system or process is not compatible with liquid oxygen (see below). Accelerating combustion effect of liquid oxygen Oxygen is not flammable, but it vigorously accelerates and supports combustion. Substances that burn in air will burn more vigorously in oxygen. Do not permit liquid oxygen or oxygen rich atmosphere to come into contact with organic materials or flammable substances of any kind. Some organic materials which can react violently with liquid oxygen include oil, grease, asphalt, kerosene, cloth, tar and dirt. Oxygen deficiency/Asphyxiation All cryogenic liquids have a significant potential for creating an oxygen deficient environment. Because of their large liquid to gas expansion ratios, even small quantities of liquefied gas can expand to displace large amounts of oxygen, thereby rendering the atmosphere in a confined area lethal. Without adequate oxygen, one can lose consciousness in a few seconds and die of asphyxiation in a few minutes.
The most likely cause of frostbite to the hands and body is by contact with cold metal surfaces. Because there is no protective layer of gas formed, frostbite will occur almost instantaneously when touching surfaces that have been cooled by cryogenic liquids. Hand protection is primarily required to guard against the hazard of touching cold surfaces. Loose, non-asbestos insulating gloves that can be easily removed may be worn. The use of an insulated pot holder is the preferred method of handling cold surfaces. Never use rags to handle cold surfaces. Use tongs to add or remove materials from cryogenic liquids. Protective clothing Closed toed shoes are required when handling cryogenic liquids. Long cuffless trousers which cover the neck of the shoes should also be worn. Long sleeve shirts are also recommended for arm protection. An apron made of leather or other material recommended for use with cryogens is indicated when large quantities of cryogen hare handled.
6. Use care in transporting fragile cryogenic containers. Use a hand truck for transport. Always transport cryogenic liquids in service elevators when available. Storage 1. Store in a well ventilated area to prevent buildup of flammable gases or air displacement 2. Use only approved storage vessels having pressure relief valves. 3. Avoid contact of moisture with storage containers to prevent ice plugging of relief devices. 4. Periodically check container necks for ice plugging; core out plugs if present. 5. Keep all sources of ignition away from cryogenic liquids.
First Aid
If medical attention is needed following a skin or eye exposure to a cryogenic liquid, immediately call 9-911 and then call 2-9090 (the College Emergency Action Directors line). All personnel using cyrogenic liquids must also be familiar with first aid procedures for treating frostbite: 1. Warm the affected area of the body rapidly by immersion in water not to exceed 105 F, with body heat, or by exposure to warm air. In the event of massive exposure, the emergency shower should be used to warm the body. All clothing must be removed prior to showering. Maintain the affected area of the victim at normal body temperature until medical help arrives. 2. Calm the victim and avoid aggravating injury. People with frostbitten feet should not walk on them. Do not rub or massage the affected parts of the body. 3. Prevent infection--use a mild soap to clean the affected area. Dressings need not be applied if the skin is intact. 4. If affected, flush eyes with warm water for 15 minutes.