SIGNUM 120 MINUTES FIRE RATED PRESSED STEEL DOOR WITH STEEL FRAME CONFORMING TO STABILITY AND INTEGRITY.
1. Steel Fire rated doors shall be manufactured in a unit certified for its quality systems by ISO 9001:2008 certificate. a) Steel frame shall have frame profile of size minimum 143mm x 57mm constructed from minimum sheet thickness of 1.0mm. Galvanized steel sheets conforming to IS 513: 2008 for its physical and chemical properties shall be used for frames. Frames shall have the following: i) Provision for anchor bolt fasteners on each vertical jamb for fixing to Wall/RCC surface. Center to center distance between the anchor fasteners shall not be more than 600 mm. ii) Anchor bolts shall be of minimum size M8 x 80mm duly treated for corrosion resistance. iii) 2 mm thick base plates at all pre-punched cut outs and surface mounted hardware item as a provision to receive hardware and Ironmongery. iv) 3 mm thick hinge back plate with blind rivet nut M6 x 16 mm zinc plated pre-fixed to receive hinges for screw mounted fixing. v) Provision for Lock striking plate c) d) Frames shall be fabricated at factory, bolted at top jamb to vertical jamb for direct installation at site. All cut outs including hinge back plates, strike plates with predrilled holes shall have mortar guard cover to prevent cement, dust ingress into cutouts. Door frames shall be suitably cleaned and finished powder coated as per standard RAL colour shade approved for the project. Alternatively door frames can be finished using anticorrosive zinc rich two component epoxy stoving primer and top coat of two component polyurethane paint of approved colour shade for the project. Door frames shall be solid grouted at site using sand: cement mortar mix at 5:1 proportion by volume. STEEL DOOR SHUTTERS a) Fire rated shutters shall be constructed from 0.9mm thick galvanized steel sheet conforming to IS 513: 2008 for its physical and chemical properties. Page 1 of 2
b)
e)
f)
b) Fully flushed double skin doors shall have folded interlocking sheet seam arrangement at stile edges covering the infill core. There will not be welded or fused-jointed finished stile edges. c) Shutters shall either face. have no screwed, welded, riveted joints on
d) Shutter shall have 3 mm thick hinge back plate with blind rivet nut M6 x 16 mm zinc plated pre-fixed to receive hinges for screw mounted fixing. e) The infill material shall be proprietary light weight material capable of being sandwiched between the sheets on two faces of the shutter, using suitable permanent glue. Shutter shall be suitable for a fire rated door with stability and integrity up to 120 minutes when tested as per standard heating conditions as specified in IS:3614 Part 2. The type test report shall be made available for the latest type test conducted to Indian Standard specifications IS 3614 Part 2. Test report shall be submitted for a test conducted not earlier than five years for similar construction of fire rated door as per above specifications. Type test shall be certified by CPRI or CBRI f) Shutters shall be fully factory made with pre-punched machined cutouts to receive Iron Mongery at suitable locations, concealed encasings for mortise lock, flush bolts, drop down gaskets etc. 2mm thick back plates shall be provided at suitable locations for surface mounted Iron Mongery provisions as per approved drawings for the project. g) Shutters shall be finished powder coated at factory as per the colour shade approved for the project. Alternatively shutters can be finished using anticorrosive zinc rich two component epoxy stoving primer and top coat of two component polyurethane paint of approved colour shade for the project. h) Overall thickness of the shutter shall be 48 (+-2) mm accept standard brands and Models of Iron Mongery items. to
Page 2 of 2