Advanced Fuel Cell Test System: Features

840 Advanced Fuel Cell Test System New!!! Integrated Turn-Key Test System Increased Flow Rate Capability 6-12 SLPM Humidifier Bypass for wet / Dry Testing Multiple Current Ranges for Accurate Measurement Over Wide Dynamic Range Impedance Spectroscopy and HFR Option Anode and Cathode Gas Mixing Options Suitable for up to 50 cm2 cells and small stacks 890e Electronic Load: 125W (5 / 25 / 50A or 10

Uploaded by

Davi Batalha
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views2 pages

Advanced Fuel Cell Test System: Features

840 Advanced Fuel Cell Test System New!!! Integrated Turn-Key Test System Increased Flow Rate Capability 6-12 SLPM Humidifier Bypass for wet / Dry Testing Multiple Current Ranges for Accurate Measurement Over Wide Dynamic Range Impedance Spectroscopy and HFR Option Anode and Cathode Gas Mixing Options Suitable for up to 50 cm2 cells and small stacks 890e Electronic Load: 125W (5 / 25 / 50A or 10

Uploaded by

Davi Batalha
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

840 Advanced Fuel Cell Test System

New!!!
Integrated Turn-Key Test System Increased Flow Rate Capability 6-12 SLPM Humidifier Bypass for Wet/Dry Testing Multiple Current Ranges for Accurate Measurement Over Wide Dynamic Range Impedance Spectroscopy & HFR Option Anode & Cathode Gas Mixing Options

Features:
Suitable for up to 50 cm2 cells & small stacks 890e Electronic Load: 125W (5/25/50A or 10/50/100A) 20V; or 500W (12/62/125A or 25/125/250A) 20V 892e Data Acquisition Module: 16 channels of voltage/temperature integrated with FuelCell Dual Anode & Cathode mass flow controllers for enhanced accuracy over wide flow range New: Automated Anode & Cathode input gas selector valves Automated humidifier by-pass for wet/dry cycling Large capacity Anode & Cathode SS humidifiers with automatic water fill Flexible SS temperature controlled heated gas transfer lines FuelCell software for user-friendly computercontrolled cell operation & experimentation Constant or stoichiometric-controlled reactant flow rate Constant current, voltage or power control modes Continuous, real time cell resistance measurement by Current Interrupt & HFR High impedance whole cell & reference electrode voltage sense inputs Simultaneous 3 channel whole and half-cell EIS Automatic shutdown & purge for safe, reliable operation Single USB interface

Available Options:
Anode & Cathode backpressure standard & high capacity Built-in impedance analyzer for EIS & HFR 32 channel stack voltage monitor Additional MFCs for gas mixing on Anode & Cathode

From the makers of:

Specifications:
Electronic Load: Maximum Load Current: Maximum Load Power: Minimum Load Resistance: Current Resolution: Current Accuracy: Voltage Measurement and Data Acquisition: Max. Whole Cell Voltage: Max. Reference Electrode Voltage: Voltage Resolution: Voltage Accuracy: Voltage & Current Data Update Rate: Whole Cell Sense Input Resistance: Reference Electrode Input Resistance: Impedance Analyzer (Optional 880): Internal Impedance Analyzer Type: Internal Analyzer Frequency Range: Measurement Channels: Reactant Gas Control System: 5/25/50A; 10/50/100A; 12/62/125A; 25/125/250A (config. dependent) 125 W or 500 W (configuration dependent) < 2 m (100 mV @ 50 A at load terminals) 1 mA at low currents up to 100mA (current setting dependent) 0.3% of full scale current of selected range

20 V 9.999 V 1 mV 3 mV 0.3% of reading 100 Hz > 35 k 9 > 10

Single sine, one generator and two gain/phase measurement channels 1 mHz to 10 kHz Three: whole cell plus two half cell vs. Reference Electrode All 316 SS construction (humidifiers, flow path, valves and mass flow controllers) with Swagelok fittings Temperature controlled reactant transfer lines Anode 6 SLPM (1 + 5 SLPM) and Cathode 12 SLPM (2 + 10 SLPM) Dual rate software controlled mass flow controllers Automatic N2 purge valves Gas supply pressures (3), humidifier water levels (2), external (1), System alarm output (1) Standard: manual control, 0 30 PSIG High Capacity: forced air condensers with large tanks and SS regulators Five: cell, anode humidifier, anode line, cathode humidifier, cathode line 0.25% of span, 1 least significant digit Thermocouple, Type T for cell (Type K optional for high temperature) Dual sparger-type, passivated 316L, 1650 W heaters per bottle Ambient to 99 C Automatic Water fill (requires 45 PSIG min., or 20 PSIG above back pressure water feed) 5 to 35 C 220-240 V, 50-60 Hz, 20 A Single bench top enclosure 32 H x 24 W x 24 D (+ 16 for heated gas lines), 120 lbs. 32 H x 24 W x 24 D (+ 16 for heated gas lines), 120 lbs.

Mass Flow Control:

Alarm Inputs:

Backpressure Control(Optional):

Temperature Controllers: Set & Report Accuracy: Sensor Type: Humidifiers: Temperature Range: Fill Method: Environment: Operating Temperature: Power Source: Enclosure Type: Size and Weight: Safety Features:

Automatic shutdown and N2 purge on under-voltage, over-current, over-temperature, loss of reactant or purge gas pressure, low water, communications failure or external alarm Emergency Stop switch for manual operator shutdown
Specifications given for 25 C ambient temperature unless otherwise noted.

Copyright 2002-2010 Scribner Associates, Inc. Prices and/or specifications subject to change without notice. FuelCell, ZPlot and CorrWare are registered trademarks of Scribner Associates, Inc.

150 E. Connecticut Ave., Southern Pines, North Carolina 28387 Phone (910) 695-8884 Fax: (910) 695-8886 www.scribner.com

[email protected]