Ds Uhp Wuc 1x en Us 20710
Ds Uhp Wuc 1x en Us 20710
Applications
Semiconductor, flat panel display and photovoltaic industry Specialty and bulk gas distribution systems (Gas Sticks, Gas Panels, VMBs)
Special Features
Compact design ATEX and IECEx Zone 2 approval FM Class 1 Div 2 Groups A,B,C,D Ingress protection NEMA 4 (IP 67) with side access zero point adjustment Excellent EMC stability Active temperature compensation RoHS compliant
Fig. left Transducer WUC-10, Single End Fig. center Transducer WUC-15, Flow Through Fig. right Transducer WUC-16, Modular Surface Mount
Standard Features
Compact The ultra compact design of the WUC-1X meets the smallest product footprint requirements. The space saving design easily replaces competitive transducers, making it the perfect fit for new equipment and retrofit projects. Our flow through (WUC-15) and surface mount (WUC-16) series transducers are specifically designed and manufactured to sustain torsion applied stresses often incurred during installation. The special design of our thin film sensor eliminates the risk of sensor signal error due to influenced loads at the pressure connection or welded joints. Versatile The highest materials of construction ensure that every WUC-1X series transducer is well suited for use in corrosive or non-corrosive medias. Additionally, because every WUC-1X series transducer comes standard with NEMA4, ATEX, IECEx and FM certifications, it can be confidently installed in indoor or outdoor systems as well as in non-flammable or potentially flammable areas. The sealed side access zero point adjustment prevents entry of moisture when used outdoors. The transducers non-incendive ATEX, IECEx and FM approvals for potentially flammable environments provide essential safeguards for life and product safety. Carrying a T6 temperature class designator, WUC-1X series transducers easily meet the measurement requirements for low, spontaneous ignition temperature medias such as phosphine (PH3) and silane (SiH4). Reliable Active temperature compensation reduces the transducers impact to changing temperatures and provides for safer operations in purge-vent cycling of high Joule-Thomson effect gases. The hermetically sealed design of the transducers zero point potentiometer protects against unintentional change as well as prevents entry of moisture when used outdoors. The transducers thin film sensors are made of 2.4711/UNSR 30003 to ensure high corrosion resistance and excellent hysteresis characteristics. The remaining wetted components are made from 316L VIM/VAR stainless steel. Prior to final assembly, all wetted parts are electropolished and cleaned using the latest techniques and industry standards. Individual testing of each transducer guarantees compliance with the requirements for leak integrity, overpressure stability, accuracy, and particles levels according to the applicable and relevant SEMI standards.
Page 1 of 10
R
Specifications
Pressure ranges psi 30 60 100 160 bar 2 4 7 11 Over pressure safety 1) psi 120 120 210 320 psi 1800 1800 2200 2600 Burst pressure 1) Other pressure ranges and pressure units (e.g. MPa, kg/cm2) on request 1) 1 psi = 0.069 bar Measuring principle Metal thin film sensor Materials nWetted parts Pressure Connection 316L VIM/VAR Pressure sensor 2.4711 / UNS R30003 nCase 304 SS
Particle test 0.1 m Particle 0.1 ptc / ft according to Semi E49.8 Inboard helium leak test < 1 x 10-9 mbar l/sec (atm STD cc/sec) according to Semi F1 Surface finish Electropolished, typical Ra 0.13 m (RA 5); max. Ra 0.18 m (RA 7) according to Semi F19 Dead volume cm3 WUC-10 < 1.5, WUC-15 < 1, WUC-16 < 1 Permissible Medium Special gas / Vapour / Liquid Power supply U+ U+ in VDC 10 ... 30 with output signal 4 ... 20 mA / DC 0 ... 5 V 14 ... 30 with output signal DC 0 ... 10 V Signal output and RA in Ohm 4 ... 20 mA, 2-wire RA (U+ 10 V) / 0.02 A maximum ohmic load RA 0 ... 5 V, 3-wire RA > 5 k 0 ... 10 V, 3-wire RA > 10 k Power Pi W 1 % of span -5 up to +3.5 (via potentiometer) Current output signal Adjustability zero % of span -2 up to +5 (via potentiometer) Voltage output signal Response time (10 ... 90 %) ms 300 Insulation voltage VDC 500 Accuracy % of span 0.2 ( 0.4 with pressure ranges 2 bar) RSS (Root Sum Squares) incl. Linearity, Hysterisis, non-repeatability % of span 0.5 2) (1.0 2) with pressure ranges 2 bar) 2) Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement per IEC 61298-2) Non-linearity % of span 0.1 ( 0.15 for pressure ranges 2 bar) (BFSL) according to IEC 61298-2 Hysteresis % of span 0.14 Non-repeatability % of span 0.12 % of span 0.25 typ. (at reference conditions) 1-year stability Permissible temperature of without Approval T4 T5 T6 nMedium -20...+100C -4...+212F -20...+85C -4...+185F -20...+60C -4...+140F -20...+40C -4...+104F nAmbience -20...+85C -4...+185F -20...+85C -4...+185F -20...+60C -4...+140F -20...+40C -4...+104F nStorage -40...+100C -40...+212F -40...+100C -40...+212F -40...+100C -40...+212F -40...+100C -40...+212F Related temperature range -20 ... +80 C / -4 ... +176 F (active compensated) Temperature coefficients within related temperature range (active compensated): nmean TC of zero % of span 0.1 / 10 K nmean TC of range % of span 0.15 / 10 K RoHS-conformity Yes (not with bayonet connector) CE-conformity nPressure equipment directive 97/23/EC nEMC directive 2004/108/EC, EN 61 326 Emission (Group 1, Class B) and Immunity (industrial locations) nDirective ATEX of equipment 94/9/EC intended for use in potentially explosive atmospheres Ex-protection ATEX & IECEx Category 3) 3G (for transducers with Ex-marking) Ignition protection type II 3G Ex nA ic IIC T4/T5/T6 Gc (for transducer with Ex-marking) FM FM; Nonincendive for use in Class I, Div. 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, Hazardous (Classified) Locations
3)
Read the operating conditions and safety-relevant data in the operating instruction in any case WIKA Datasheet WUC-1X 8/2013
Page 2 of 10
Specifications
Assembly and packing area Packaging Shock resistance Vibration resistance Wiring protection Short-circuit Reverse polarity Weight g
kg
permitted range
Electrical connections
Bayonet connector, 4-pin Circular connector M12x1, 4-pin Flying leads, 3m Sub-D HD connector, 15-pin
U+ = A U+ = A -
U- = D U- = D S+ = B
U+ = 1 U+ = 1 -
U- = 3 U- = 3 S+ = 4
U+ = red U- = black
U+ = 7
U+ = red U- = black S+ = brown U+ = 7 0.22 mm2 (AWG 24) 4.8 mm NEMA 4 (IP 67) (IP 54)
U- = 5 U- = 12 U- = 5 S+ = 2 U- = 12
The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors that provide the corresponding ingress protection. Page 3 of 10
Page 4 of 10
1/4 Fixed Male Face Seal 1/4 Fixed Male Face Seal
1/4 Fixed Male Face Seal High Flow Through 1/4 Fixed Male Face Seal High Flow Through only available with pressure ranges up to 25 bar / 300 psi
1/4 Swivel Femal Face Seal 1/4 Swivel Male Face Seal
Page 5 of 10
Page 6 of 10
Page 7 of 10
Page 8 of 10
Page 9 of 10
Order Code:
WUC-1
10 11
12 13*
Page 10 of 10
2013 WIKA Instrument, LP. All Rights Reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.
WIKA Instrument, LP 1000 Wiegand Boulevard Lawrenceville, GA 30043-5868 Tel: 888-WIKA-USA 770-513-8200 Fax: 678-739-2569 E-Mail: [email protected] www.wika.com/uhp