This document provides product specifications for HVC-VCD aluminium volume control dampers. It describes the dampers' lightweight aluminium construction, protected linkage system, standard and optional sizes and features. These include different frame and blade options, as well as control options like handles, actuators, locking quadrants and extended spindles. Additional options include high temperature specifications and stainless steel side seals.

Uploaded by

omarsosa#747
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views

VCD

This document provides product specifications for HVC-VCD aluminium volume control dampers. It describes the dampers' lightweight aluminium construction, protected linkage system, standard and optional sizes and features. These include different frame and blade options, as well as control options like handles, actuators, locking quadrants and extended spindles. Additional options include high temperature specifications and stainless steel side seals.

Uploaded by

omarsosa#747
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 0

V2.

0
Incorporating
Product spec >>>
> Series HVC-VCD - Aluminium volume control dampers
www.h-v-c.comfor live UK stock levels
Recommended for:
Volume control
General
Aluminium volume control damper fully open
Overview
Excellent all purpose VCD
Lightweight aluminium construction
With their large format 100mm deep
frame and lightweight aluminium
construction, HVC-VCDs are able to be
made in sizes much larger than their steel
NCA cousins.
Incorporating the HVC standard out of
airstream blade linkage, the precision parts
are never exposed to the airstream for
protection against dust and moisture.
Standard - Extruded aluminium frame & blades.
Optional - Galvanised steel frame.
Frame screwed together using self tapping screws.
Blades held on nylon / zinc axles.
Standard - 100mm deep, 40mm risers.
Optional - 100mm deep, 40mm & 10mm risers.
Standard - None.
Optional - Teardrop fixing holes at each corner.
Minimum size single unit 100mm x 100mm.
Maximum size single unit 2900mm x 2900mm.
Mullions fitted above 1200mm wide.
Standard - Ergonomic plastic handle.
Optional - Actuators (electronic and pneumatic),
locking quadrants, chains, extended
spindle.
Standard - Mill aluminium.
Optional - Painted to any RAL / BS colour.
Aluminium volume control
Dampers
Specifications:
Materials:
Construction:
Frame:
Fixings:
Sizes:
Operation:
Finish:
14 kg Mass/M sq face area:
Protected linkage
As with all HVC Volume Control
Dampers, linkages are held
entirely outside of the airstream
within the frame. This stops dust
and dirt carried in the air from
settling on linkages, extending
maintenance intervals.
High temperature
The optional high temperature
specification enables HVC VCDs
to be used in environments
reaching up to 300C. Brass
bushes and link arms replace the
standard nylon fittings.
2
www.h-v-c.com
HVC-VCD
Series
3
Models
Model A - Square flanged
Model B - Square spigotted
www.h-v-c.comfor live UK stock levels
Aluminium volume control
Dampers
4
Models
Model C - Circular spigotted
Model D - Flat oval spigotted
www.h-v-c.com
HVC-VCD
Series
5
Frame types
Standard 40:40 frame 40:10 frame, designed for wall mounting
Blade options
1. Aerofoil
2. Aerofoil with edge seals
3. Standard blade
4. BDS blade, can have edge seals.
All blades on 75mm pitch.
Opposite blade motion is standard with blade
types 1, 2 and 3. Parallel is optional.
Blade type 4 must use parallel motion.
1 2 3 4
www.h-v-c.comfor live UK stock levels
Aluminium volume control
Dampers
6
Control options
Plastic handle
The standard control option with HVC-VCDs is a red
plastic handle. Ergonomically designed for maximum
grip, each one has a visual position indicator, showing
blade angle, and a central locking screw.
Actuators
The full range of Belimo actuators are available for
factory fitment to HVC-VCDs. Most models are held on
the shelf, including the versatile SM series.
For specialist applications, pneumatic or explosion
proof models are also available.
Locking quadrant
Made from cast aluminium, locking quadrants give
greater leverage than plastic handles making them
easier to operate.
They also incorporate a visual position indicator,
and locking mechanism by way of a wingnut.
Extended spindle
If you wish, we can fit a steel extended spindle to
allow motor fitment on site. The spindle protrudes
around 130mm from the damper case, and has a
12.7mm diameter.
www.h-v-c.com
Large units
Mullions are used where units exceed a multiple of
1200mm wide, and being connected through the
mullion via aluminium shafts, the blades still operate as
a single pack.
For example, a 1250mm wide damper would have a
single, central mullion. While a 2450mm wide, if not
made in sections would have two mullions.
HVC-VCD
Series
Further options
High temperature specification: HT
Replacing the standard red and black nylon parts with steel
and brass parts enables HVC-VCDs to be used in
environments where temperatures will reach up to 300C.
High temperature and standard linkage components
Stainless steel side seals: SS
To enhance shut off, stainless steel edge seals can be
fitted. Best fitted in combination with blade edge seals.
VCD showing side seals and sealed aerofoil blades
600 x 600 HVC-VCD Model A
SIZE
(Nominal / overall w x h [mm])
SERIES
MODEL
Square flanged.......... Model A
Square spigotted..... Model B
Circular spigotted...... Model C
Flat oval spigotted..... Model D
SM230A
CONTROL OPTION
Plastic handle................ STD
Locking quadrant........... LQ
Extended spindle........... EX
Belimo actuator.............[Code]
HT
ACCESSORIES
High temperature spec...... HT
Blade edge seals............... ES
Stainless side seals........... SS
Note: If HT is specified, ES
cannot be fitted
40:40
FRAME
40mm risers................. 40:40
40 & 10mm risers......... 40:10
7
Grilles & diffusers
Louvres
Fire / Fire smoke dampers
Volume control dampers
Supplies Ltd
All references to companies not
part of the HVC group of
companies are used with the
permission of their respective
owners.
All details within this brochure are correct at time of going to print. However
HVCs policy is one of continual product development. The right is reserved to
alter any details published in this brochure without any prior notice. Any
changes will appear on www.h-v-c.com as soon as is practically possible.
All information in this brochure is designed to be used for informative purposes
only. HVC will not be legally bound by anything contained within this
publication, or any other information distributed.
www. h- v - c . c om

You might also like