eNodeB Commissioning Guide by Using LMT V1 2
eNodeB Commissioning Guide by Using LMT V1 2
Procedure:
Note: USB-Ethernet adaption cable come with site materials. 3. Login the eNodeB via internet explorer.
Open internet explorer and input address http://192.168.0.49 Default Username: admin Default password: hwbs@com
When you login, it remind as below. Please change password to: Huawei@123
b.
c.
Install the FTP software and run the ftp server file:
Remark:
1. Double click SFTPServer.exe to run the FTP software. If the ftp server is running, you will see the green button on windows task bar.
2.
The FTP server default user name and password is admin and admin. You can change it if you want: Right click the green button, put the new user name and password. Click ok to save the new user name and password.
Put your eNodeB software to D:\eNodeBCommission\Software, Put the eNodeB database to D:\eNodeBCommission.
In the navigation tree, double-click Download and Activate Software. The Download and Activate Software window is displayed. Select Download Version Software and Activate Version Software. Then there is text displayed, please fill out target version. For example: Target version is V100R005C00SPC370, then click Execute. If Delay Download Flag set to NO(Not Delay Download), do not need use Step SPL
software. But download time will longer.
After it success, eNodeB will restart. Then run command DSP BRDVER, to check all boards software version.
2. License Installation
The installation is also done through the ftp server as its done with the software: INS LICENSE: DIR="D:\eNodeBCommission", FN="LTE_Commission_License.dat", FLG=YES, MODE=IPV4, IP="192.168.0.50", USR="admin", PWD=admin;
Remark: the eNodeB configuration file name must include the external name .xml when you input the source file name in LMT.
b. Execute the command and monitor the download progress till to success c. Check the result: Run the command: LST CFGFILE: FT=XML;, to see if the testlab.XML is downloaded in the system:
Remark: After active the configuration, the eNodeB will reboot automatically.
b.
Vlan checking, Use this command you can check the VLAN that you configured in eNodeB.
LST VLANMAP
c.
Route checking:
LST IPRT:;
d.
Ping test. Use this command, you can test the transmission is ready or not. PING: SN=7, SRCIP="eNodeB Device IP", DSTIP="Next Hop IP", CONTPING=DISABLE, APPTIF=NO;