0% found this document useful (0 votes)
223 views8 pages

International Limited: Certificate of Visual Examination and Mpi

The document contains 6 certificates issued by JC International Limited certifying that 6 pieces of equipment, including various sizes of single joint elevators, underwent magnetic particle testing on January 24, 2014. The inspector, OGEH EMEDOH, found no defects on any of the equipment. Each certificate provides details of the equipment, testing method used, specifications met, results and signatures. All tests were conducted at the MAGELLAN premises and the equipment owner is listed as Transocean Support Services.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
223 views8 pages

International Limited: Certificate of Visual Examination and Mpi

The document contains 6 certificates issued by JC International Limited certifying that 6 pieces of equipment, including various sizes of single joint elevators, underwent magnetic particle testing on January 24, 2014. The inspector, OGEH EMEDOH, found no defects on any of the equipment. Each certificate provides details of the equipment, testing method used, specifications met, results and signatures. All tests were conducted at the MAGELLAN premises and the equipment owner is listed as Transocean Support Services.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202056 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

2.3/8-5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

NL 0147586

Left Ear Diameter: 7/8 Right Ear Diameter: 7/8 Top Bore Diameter: 7 Bottom Bore Diameter: 5.1/2 Door Gap: 3/16 Hinge Gap: 1/4" SWL: 5 Tons Manufacturer: VARCO BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202057 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

2.3/8-5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

NL 0147587

Left Ear Diameter: 7/8 Right Ear Diameter: 7/8 Top Bore Diameter: 7 Bottom Bore Diameter: 5.1/2 Door Gap: 1/4 Hinge Gap: 1/4" SWL: 5 Tons Manufacturer: VARCO BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202058 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

8.5/8- 10.3/4 OD SINGLE JOINT ELEVATOR

DIMENSIONS

12671

Left Ear Diameter: 13/16 Right Ear Diameter: 13/16 Top Bore Diameter: 6.5/8 Bottom Bore Diameter: 8.5/8 SWL: 5 Tons Manufacturer: VAR BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202059 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

7 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3493

Left Ear Diameter: 3/4 Right Ear Diameter: 3/4 Top Bore Diameter: 7 Bottom Bore Diameter: 7 Door Gap: 1/16 Hinge Gap: 1/4" SWL: 5 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202060 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

7 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3487

Left Ear Diameter: 11/16 Right Ear Diameter: 11/16 Top Bore Diameter: 7 Bottom Bore Diameter: 7 Door Gap: 1/8 Hinge Gap: 7/16" SWL: 5 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202061 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3178

Left Ear Diameter: 11/16 Right Ear Diameter: 11/16 Top Bore Diameter: 5.1/2 Bottom Bore Diameter: 5.1/2 Door Gap: 9/16 Hinge Gap: 7/16" SWL: 2 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202062 Identification Number Date of Examination 07/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 IEU DRILL PIPE ELEVATOR

DIMENSIONS

NL 46430

Left Ear Diameter: 4.3/4 Right Ear Diameter: 6 Top Bore Diameter: 7.13/16 Middle Bore Diameter: 5.3/4 Bottom Bore Diameter: 5.15/16 SWL: 350 Tons Manufacturer: VARCO BJ TYPE-(GG) AIR OPERATED ELEVATOR
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: CANTILEVER DECK
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 07/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202063 Identification Number Date of Examination 09/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 IEU DRILL PIPE ELEVATOR

DIMENSIONS

NL 0147092

Left Ear Diameter: 4.3/4 Right Ear Diameter: 4.3/4 Top Bore Diameter: 7.7/8 Middle Bore Diameter: 5.7/8 Bottom Bore Diameter: 5.7/8 Hinge Gap Diameter: 1/4 Door Gap Diameter: 5/16 SWL: 350 Tons Manufacturer: VARCO BJ TYPE-(GG) AIR OPERATED ELEVATOR
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: CANTILEVER DECK
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 09/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

You might also like