Defect / Non Compliance Report: International Limited

EGBEBU IFEANYI LEEA, SNT LEVEL II MT, PT & UT Qty Description of Equipment SHACKLE SWL Shackle ID: AD 02 1pc Bow Safety Pin Shackle 1t LOCATION: WARE HOUSE Particulars of defects found which are, or could, become a danger to persons or ‘none’ Particulars of any repair, alteration to remedy defect or ‘none’ No manufacturer’s name / logo (Not Remove from service Address of premises where Test / Examination was held: fit for Use) Name and

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views

Defect / Non Compliance Report: International Limited

EGBEBU IFEANYI LEEA, SNT LEVEL II MT, PT & UT Qty Description of Equipment SHACKLE SWL Shackle ID: AD 02 1pc Bow Safety Pin Shackle 1t LOCATION: WARE HOUSE Particulars of defects found which are, or could, become a danger to persons or ‘none’ Particulars of any repair, alteration to remedy defect or ‘none’ No manufacturer’s name / logo (Not Remove from service Address of premises where Test / Examination was held: fit for Use) Name and

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83275 Identification Number Qty

01/11/2012

EGBEBU IFEANYI Description of Equipment

LEEA, SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


10908/1 1pc

64mm X 45.73m X Single leg sling c/w closed wedge socket at all ends

52.4tonnes

LOCATION: MAIN DECK PORT SIDE AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessive corrosion, pitting.

Remove from Service


Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

TRANSOCEAN SUPPORT SERVICE NIG LTD

AD 10

We hereby certify that on 01/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83276 Identification Number Qty

01/11/2012

EGBEBU IFEANYI Description of Equipment

LEEA, SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


FJ 264 1pc

64mm X 125ft X Single leg sling c/w closed wedge socket at all ends

49.3tonnes

LOCATION: MAIN DECK STBD SIDE AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessive corrosion, pitting.

Remove from Service


Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

TRANSOCEAN SUPPORT SERVICE NIG LTD

AD 10

We hereby certify that on 01/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83277 Identification Number Qty

26/10/2012

EGBEBU IFEANYI Description of Equipment

LEEA, SNT LEVEL II MT, PT & UT

SWL

SHACKLE
AD10/01 1pc

Bow Safety Pin Shackle

85T

LOCATION: BOW SIDE MAIN DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturer name and logo.

Remove from Service


Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

TRANSOCEAN SUPPORT SERVICE NIG LTD

AD 10

We hereby certify that on 26/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83278 Identification Number Qty

26/10/2012

EGBEBU IFEANYI Description of Equipment

LEEA, SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


121209PL/1 1pc

64mm X 30m X Single leg sling c/w 21/2-25/8 closed spelter socket both ends

55t

LOCATION: BOW SIDE MAIN DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessively corroded.

Remove from Service


Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

TRANSOCEAN SUPPORT SERVICE NIG LTD

AD 10

We hereby certify that on 26/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

84452 Identification Number Qty

03/11/2012

EGBEBU IFEANYI Description of Equipment

LEEA, SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


26110PL/4 1pc

19mm X 1.7m X Single leg sling c/w soft eye both ends

4.6tonnes

LOCATION: MAIN DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessively corroded and permanent bend.

Remove from Service


Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

TRANSOCEAN SUPPORT SERVICE NIG LTD

AD 10

We hereby certify that on 03/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85146 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 01

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85147 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 02

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85148 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 03

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85149 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 04

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85150 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 05

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85151 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 06

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 22/10/2012

Examiner

Qualifications

85152 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID: AD 07

1pc

Bow Safety Pin Shackle

1t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No manufacturers name / logo


(Not

Remove from service


Address of premises where Test / Examination was held:

fit for Use)

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 22/10/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 10/11/2012

Examiner

Qualifications

85153 Identification Number

EGBEBU IFEANYI

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: CFGE / 01A

1set

16mm X 2.2m X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

6.3 t

LOCATION: WARE HOUSE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link not up to 270 X 140mm in Dimension


(Not

Remove from service

fit for Use)


Address of premises where Test / Examination was held:

Name and address of equipment owner:

Transocean Support Services

AD 10

We hereby certify that on 10/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT, & UT

85222 Identification Number

08/11/2012

EGBEBU IFEANYI

Qty

Description of Equipment WIRE ROPE SLING

SWL

1365967-1-220

19mm X 7ft X 1 leg sling c/w thimble eye all ends

5.6t

LOCATION: UNDER CANTILEVER


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessive Corrosion and Pittings (Not fit for Use)


Name and address of equipment owner:

Remove from service


Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 08/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT, & UT

85223 Identification Number

08/11/2012

EGBEBU IFEANYI

Qty

Description of Equipment WIRE ROPE SLING

SWL

1365967-1-221

19mm X 7ft X 1 leg sling c/w thimble eye all ends

5.6t

LOCATION: UNDER CANTILEVER


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessive Corrosion and Pittings (Not fit for Use)


Name and address of equipment owner:

Remove from service


Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 08/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT, & UT

85224 Identification Number

10/11/2012

EGBEBU IFEANYI

Qty

Description of Equipment WIRE ROPE SLING

SWL

OSL/TSS 4043

26mm X 10ft X 1 leg sling c/w soft eye all ends

8.7t

LOCATION: CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Excessive Corrosion and Permanent bent (Not fit for Use)


Name and address of equipment owner:

Remove from service


Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 10/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 08/11/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT, & UT

84856
Identification Number Qty

EGBEBU IFEANYI

Description of Equipment WIRE ROPE SLING

SWL

SLING ID: OSL/TSS 4555

16mm X 4ft X single leg sling c/w thimble eye at all ends

3.3

tonnes

LOCATION: STBD SIDE AFT


Particulars of defects found which are, or could, become a danger to persons or none Excessive corrosion and pitting (Not fit for Use)
Name and address of equipment owner:

Particulars of any repair, alteration to remedy defect or none Remove from service
Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 08/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 08/11/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT, & UT

84857
Identification Number Qty

EGBEBU IFEANYI

Description of Equipment WIRE ROPE SLING

SWL

SLING ID: OSL/TSS 4553

16mm X 4ft X single leg sling c/w thimble eye at all ends

3.3

tonnes

LOCATION: STBD SIDE AFT


Particulars of defects found which are, or could, become a danger to persons or none Excessive corrosion and pitting (Not fit for Use)
Name and address of equipment owner:

Particulars of any repair, alteration to remedy defect or none Remove from service
Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 08/11/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: EGBEBU IFEANYI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT/NON COMPLIANCE REPORT FOR SAMPSON POST PADEYE REPORT No: 84858 Equipment Name: Sampson Post Pad eye

Equipment ID: Specification: Parts Examined:

SP-35 BS 2573 Entire Body

Defect Found: Recommendation: Name of Client: Place of Inspection:

Deformed Pad eye Remove and Repair Transocean Support Services Main Deck (AD 10) Signature/Date

Inspectors Name/Qualification
EGBEBU IFEANYI

LEEA,SNT Level II MT, PT, UT Lifting Equipment Insp.

12/11/2012

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT/NON COMPLIANCE REPORT FOR SAMPSON POST PADEYE REPORT No: 84859 Equipment Name: Sampson Post Pad eye

Equipment ID: Specification: Parts Examined:

SP-36 BS 2573 Entire Body

Defect Found: Recommendation: Name of Client: Place of Inspection:

Deformed Pad eye Remove and Repair Transocean Support Services Main Deck (AD 10) Signature/Date

Inspectors Name/Qualification
EGBEBU IFEANYI

LEEA,SNT Level II MT, PT, UT Lifting Equipment Insp.

12/11/2012