The document summarizes the design of a micropile with a diameter of 1000 mm. It includes calculations of the pile capacity based on SPT boring log values down to a depth of 24 m, determining the pile has a capacity of 8741 kN. It also calculates the structural capacity of the pile using concrete grout and either an API pipe or rebar reinforcement, finding capacities of 5811.8 kN and 8966.8 kN respectively, sufficient for the specified working load of 8000 kN. Details of the pile dimensions and materials are also provided.

Uploaded by

Sohaib Anwar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
980 views

Pile Geotech Design (Engineersdaily - Com)

The document summarizes the design of a micropile with a diameter of 1000 mm. It includes calculations of the pile capacity based on SPT boring log values down to a depth of 24 m, determining the pile has a capacity of 8741 kN. It also calculates the structural capacity of the pile using concrete grout and either an API pipe or rebar reinforcement, finding capacities of 5811.8 kN and 8966.8 kN respectively, sufficient for the specified working load of 8000 kN. Details of the pile dimensions and materials are also provided.

Uploaded by

Sohaib Anwar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Design of Micropile

GEOPROFOUND ENGINEERING SDN BHD

Pile Geotechnical Design using SPT Values

Site:
1000 mm

Skin Area per m, As=


3.142

Base Area, Ab =

Factor of Safety (FoS) =

Depth
Avg SPT
Interval (m) Value, N
1
2
3
4
5
6
7
8
9
10
11
12
13.5
15
16.5
18
19.5
21
23
24

11
11
2
2
2
13
26
21
21
1
12
5
6
6
1
3
1
2
2
2

0.785
2.000

Unit
End Bear at
Pile Allowable
Skin
End Bear at Pile Ultimate
Skin
Cumulative depth,
Fric, fs Fric, Fs Skin Fric, Fs qb=min(400N/ depth, Qb
Capacity, Qult = Capacity, Qall =
3, 10000)
= 2N
(kN)
(kN)
Qult/FoS (kN)
(kN)
Fs+Qb (kN)
2
(kN/m2)
(kN/m )
22
69.1
69.1
1466.7
1151.9
1221.0
610.5
22
69.1
138.2
1466.7
1151.9
1290.1
645.1
4
12.6
150.8
266.7
209.4
360.2
180.1
4
12.6
163.4
266.7
209.4
372.8
186.4
4
12.6
175.9
266.7
209.4
385.4
192.7
26
81.7
257.6
1733.3
1361.4
1619.0
809.5
52
163.4
421.0
3466.7
2722.7
3143.7
1571.8
42
131.9
552.9
2800.0
2199.1
2752.0
1376.0
42
131.9
684.9
2800.0
2199.1
2884.0
1442.0
2
6.3
691.2
133.3
104.7
795.9
397.9
24
75.4
766.5
1600.0
1256.6
2023.2
1011.6
10
31.4
798.0
666.7
523.6
1321.6
660.8
12
56.5
854.5
800.0
628.3
1482.8
741.4
12
56.5
911.1
800.0
628.3
1539.4
769.7
2
9.4
920.5
133.3
104.7
1025.2
512.6
6
28.3
948.8
400.0
314.2
1262.9
631.5
2
9.4
958.2
133.3
104.7
1062.9
531.5
4
17.0
975.2
240.0
188.5
1163.6
581.8
4
22.6
997.8
240.0
188.5
1186.3
593.1
2464.8 7743.2
8741.0
10000.0
7854.0
16595.0
8297.5

Pile Capacity (kN)

2000

4000

10

Depth (m)

Round Pile f =

15

20

25

Specified Working Load =

8000 kN

Depth required =

13

30

(Based on given BH/MKT Report & above FoS)

3/9/2014

Design of Micropile

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Micropile Structural Capacity Calculation


Pile Diameter, f =
Grade, fcu

35

1000 mm

cement grout (w/c ratio = 0.45)


f
fy =

Use API Pipe,

88.9 mm
6.45 mm thk
2
500 N/mm (min)

Area of Steel & Concrete


As (provided) = 2prt
As = 1670.707 mm

785500 mm

Ac = p*d2/4
Ac =
Ultimate Axial Load,
fu = 0.4fcu*Ac + 0.75fy*As
fu = 11623515 N
fu =

11623.5151 kN

Taking Factor of Safety (FoS) =


fall = fu/FoS

fall =
5811.8 kN
Based on the structural capacity above, the micropile is able to take the given working load
of
5811.8 kN
Micropile Details

1000 mm

Micropile, Dia

API Pipe inside


f 88.9
6.45 mm thk

Clear spacing/Cover =

Cement grout, G
W/C Ratio 0.45 min

35

455.6

mm

3/9/2014

Design of Micropile

GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Micropile Structural Capacity Calculation


Pile Diameter, f =
Grade, fcu

35

1000 mm

cement grout (w/c ratio = 0.45)


f
fy =

Use Rebar,

32 mm
25 Nos
2
460 N/mm (min)

Area of Steel & Concrete


As (provided) = Sprbars2
2
As = 20106.19 mm

Ac = p*d /4
2

Ac =

2
785500 mm

Ultimate Axial Load,


fu = 0.4fcu*Ac + 0.75fy*As
fu = 17933637 N
fu =

17933.6366 kN

Taking Factor of Safety (FoS) =


fall = fu/FoS

fall =
8966.8 kN
Based on the structural capacity above, the micropile is able to take the given working load