TABLE OF CONTENTS
1 Introduction ................................................................................................................3
Product presentation.....................................................................................................................3 Operating principle........................................................................................................................3 Main characteristics ......................................................................................................................4 Overall dimensions .......................................................................................................................5 Main components..........................................................................................................................5 1.1 1.2 1.3 1.4 1.5
Hardware architecture............................................................................................................................6 2.2 Metrological sealing scheme .........................................................................................................6 2.3 Customer sealing ..........................................................................................................................7 2.4 Metrological label ..........................................................................................................................8
5 6
Safety instructions...................................................................................................36
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
2 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
INTRODUCTION
Corus PTZ provides the following functions : acquisition and integration of the volume measured by the meter measurement of gas temperature and gas pressure calculation of the compressibility factor (PTZ version) calculation of the conversion factor and of the volume in base conditions using a T,PT or PTZ conversion calculation of the measured and converted flow rates display of the measured and calculated data management of alarms and sending to remote central systems management of a large database multiple communication channels for local and remote operations on/off inputs and outputs
where : V Vb T Tb Pm Pb
Title : Owner :
= = = = = =
Volume at measuring conditions Converted volume at reference (base) conditions Gas temperature at metering conditions Reference (base) absolute temperature Gas absolute pressure at metering conditions Reference (base) absolute pressure
corus_guid
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
on 10/23/03
3 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Z Zb C
= = =
Gas compressibility factor at metering conditions Gas compressibility factor at reference (base) conditions Conversion factor
Overall weight (without cables) Ambient temperature range Gas temperature range IP degree Power supply Pressure sensor Temperature probe Volume input Potentially explosive atmospheres rating
: : : : : : : : :
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
4 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Display
Customer Switch
Metrology Shield
J1
1 2 3 4 5 6
J3
1 2 3
125mA
Qb Qm C Z/Z0 T P
1 2 3 4 5 6 1 2 3 4
Keyboard Connection
Programming Connector
Flash Memory
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
J5
125mA
J6
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10
J2
J4
corus_guid
on 10/23/03
5 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
I/O board
program. interface
analog front-end LF+tamper inputs LF1 input LF2 input tamper input
CPU board
program. interface
RS232
LCD board
INDEX VALUE ALARM DATA CONFIG
Unconverted volume:
00000000.000
Converted volume:
power supply
ext+ ext-
m3 Nm3
00000000.000
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
6 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
1:metrological plate protected by seal 2: metrological plate protected by seal 3: inviolable metrological label
INDEX P T Z/Z0 C Qm Qb
CONFIG
1 : customer seals
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
7 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
8 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
= = =
fixed pressure used for the T conversion gas fixed relative pressure to be programmed into the device altitude of the installation to be programmed into the device
3.2.2 PT and PTZ versions When used as a PT or PTZ converter, Corus PTZ is provided with an external absolute piezoresistive pressure sensor providing a rangeability higher than 11. Two (2) operating pressure range are available : 0,9 bara to 10 bara 7,2 bara to 80 bara
The sensor is made into a stainless steel enclosure and has an IP66 protection degree according to EN 60529. It can withstand an overpressure of 1.25 times its maximal pressure (i.e. 12.5 bara) for 30 minutes. It is equipped with a G1/4 (BSP) male terminal that allows its direct connection to the gas meter or to the gas pipe. It is delivered with a cable length of either 2.50m or 0.80m. All pressure sensors are delivered with their own characterization coefficients (12) that must be programmed into the converter so that the accuracy required by EN 12405 can be reached over the whole pressure and temperature range. The temperature measurement period is programmable from 1 to 30 seconds. This data is protected by the metrological switch. When the display is On , this period is forced to 1 second.
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
9 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Whenever the pressure leaves the operating range defined by two minimal and maximal pressure thresholds or whenever a pressure sensor failure is detected, a pressure metrological alarm is generated (see 6.2.1)
S-GERG %CO2 %N2 %H2 HSV (Cv) Specific gravity Prd Trd
AGA8
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
10 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
According the selected formula, gas composition has to be into following range : S-GERG :
0% 0% 0.55 5.27 < %CO2 < 30% < %H2 < 10% < SG < 0.9 < Cv (kWh) < 13.33
AGANX19
0% 0% 0.55 < %CO2 < < %N2 < < SG < 30% 50% 0.9
AGA8
0% 0% 0.55 < %CO2 < %N2 < SG < 30% < 50% < 0.9
3.5.1 Main LF input and unconverted volumes Corus PTZ features a low frequency (LF) input that can work up to 2 hertz and that is used to meter the unconverted volumes. The pulses sent by the meter on this input (called main LF input or LF1) are balanced by the input pulse weight and are added to the unconverted index. The input pulse weight can be chosen among the following values: 0.001 m3/pulse 0.01 m3/pulse 0.1 m3/pulse 1 m3/pulse 10 m3/pulse 100 m3/pulse 1000 m3/pulse The LF input can be associated to any gas meter that outputs LF signal or to any device that provides an electrically compliant interface: dry contact static relay open collector or open drain output
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
11 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
For its connection to the meter, it shares the same terminals (J3 and J4) and the same cable as the coherence LF input (see 4.1) and as the tamper input (see 4.2). Corus PTZ can be delivered with several different LF cables, in order to comply with all existing types of meter connections. All cables are available with length of 0.80m or 2.50m.
3.5.2 Converted volumes After every conversion, Corus PTZ updates its converted volumes: the converted index and the total converted counter are increased by the unconverted volume metered since the last conversion balanced by the conversion factor 3.5.3 Under alarm operation As long as a metrological alarm occurs, volumes are managed as specified in EN 12405: the unconverted main index continues to be incremented the under alarm unconverted counter is incremented metering on the converted main index is stopped the total converted counter is incremented during the alarm using a conversion factor based on pressure and temperature back-up values, if this function is activated with programmed values Twelve monthly temperature and one pressure back-up values are available. They can be either: programmed into Corus PTZ automatically calculated by Corus PTZ from the measures done in the past (using the database)
normal operation unconverted index converted index under alarm unconverted counter total converted counter Incremented Incremented Stopped Incremented
operation under alarm Incremented Stopped Incremented incremented with back-up values
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
12 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
13 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
14 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
COMMUNICATION
Corus PTZ provides two (2) communication ports that can be used simultaneously: an optical port a RS232 port
The RS232 port can be used for serial asynchronous (start-stop) full-duplex communications. It operates at 300 baud, 1200 baud, 2400 baud, 4800 baud, 9600 baud, 19200 baud. The RS232 port is by default in a power-down mode. When the connected device initiates a communication, it has to take in account a wake up time of a few milliseconds.
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
15 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
FUNCTIONAL DESCRIPTION
6.1 Database
Corus PTZ manages six different logs : an hourly log a daily log a monthly log an interval log an event log a parameter log 6.1.1 Hourly Log The hourly log contains up to 1440 records (2 months data) that include: the date and time the hourly unconverted consumption the hourly converted consumption the hourly under alarm unconverted consumption the hourly total converted consumption the minimum, maximum and average gas temperature the minimum, maximum and average gas pressure the minimum, maximum and average unconverted flow rate the minimum, maximum and average converted flow rate the status of the converter during the hour (presence of metrologic alarms, Date/Time change) 6.1.2 Daily Log The daily log contains up to 124 records (4 months data) that include: the date and time the daily unconverted consumption the daily converted consumption the daily under alarm unconverted consumption the daily total converted consumption the minimum, maximum and average gas temperature the minimum, maximum and average gas pressure the minimum, maximum and average unconverted flow rate the minimum, maximum and average converted flow rate the status of the converter during the day (presence of metrologic alarms, Date/Time change) The user can introduce a "gas hour" in Corus PTZ. All daily consumptions are stamped from the gas hour to the gas hour of the next day. 6.1.3 Monthly Log The daily log contains up to 24 records (2 years data) that include: the date and time the monthly unconverted consumption the monthly converted consumption the monthly under alarm unconverted consumption the monthly total converted consumption
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
16 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
the minimum, maximum and average gas temperature the minimum, maximum and average gas pressure the minimum, maximum and average unconverted flow rate the minimum, maximum and average converted flow rate the status of the converter during the month (presence of metrologic alarms, Date/Time change) the value of the main unconverted index at the end of the month the value of the main converted index at the end of the month the value of the unconverted counter at the end of the month the value of the converted counter at the end of the month the maximum unconverted consumption during the month (interval) with corresponding date/time the maximum converted consumption during the month (interval) with corresponding date/time
The user can introduce a "Gas day" in Corus PTZ. All monthly consumptions are stamped from the gas day (at the gas hour) to the gas day of the next month (at the gas hour). 6.1.4 Interval Log This log is made up of two parts: a fixed one a configurable one The configurable part allows the user to build his own database structure according to his needs. The fixed part includes the following data: the date and time the interval unconverted consumption the interval converted consumption the interval under alarm unconverted consumption the interval total converted consumption a status of the converter ((presence of metrologic alarms, Date/Time change) In the configurable part, the user can select the following fields: the minimum, maximum and average gas temperature the minimum, maximum and average gas pressure the minimum, maximum and average unconverted flow rate the minimum, maximum and average converted flow rate The value of the interval is programmable among 1, 2, 3, 4, 5, 10, 15, 20, 30 and 60 minutes. The capacity of the interval log extends from 3100 (all optional fields selected) to 5900 (no optional field selected). 6.1.5 Event Log Corus PTZ logs the occurring of all main events (alarms, reset, switches change, programming,). For each event, following data are available : Date and time of the event Nature of the event Specific value (for some event only) Status The event log has a capacity of 800 events and cannot be reset. It is circular: when it is full, every new event replaces the oldest one.
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
17 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
6.1.6 Parameter Log Corus PTZ logs the modifications of the following key parameters: temperature specific data: alarm thresholds, pressure specific data: alarm thresholds, coefficients, compressibility ratio specific data: gas composition, calorific power, conversion specific data : formula, volume specific data: index, input pulse weight, database specific or related data: interval length, gas hour and day, In case of modification of one of the above parameters, following information are stored : date and time nature of the parameter former value of the parameter new value of the parameter values of the unconverted and converted indexes The parameters log has a capacity of 200 modifications and cannot be reset. It is circular: when it is full, every new modification replaces the oldest one.
6.2 Alarms
Corus PTZ manages the following 19 alarms : T low threshold T high threshold T sensor failure P low threshold P high threshold P sensor failure pulse inputs coherence tamper input on/off input #1 on/off input #2 C factor low threshold C factor high threshold base cons. high threshold raw flow low threshold raw flow high threshold base flow low threshold base flow high threshold remaining battery life alarm external power supply
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
18 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
6.2.1 Pressure alarms Pressure alarms occur: when the gas pressure is out of the operating range [Pmin ; Pmax] when the pressure sensor is out of order. Corus PTZ manages three pressure alarms: a pressure low threshold alarm a pressure high threshold alarm a pressure sensor failure alarm These alarms are automatically disabled when a T conversion is used. When a pressure alarm occurs: the alarm icon and the 'P' icon are displayed (blinking during alarm is active) the incrementing of the main converted index is stopped if the alarm is due to a pressure sensor failure : pressure, compressibility and conversion factor are set to "not-available" on the display the total converted counter is incremented based on the back-up pressure value (if existing) the on/off outputs activated as alarm outputs are switched 'on' , if the corresponding alarm was configured for alarm output the corresponding alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.2 Temperature alarms Temperature alarms occur: when the gas temperature is out of the operating range [Tmin ; Tmax] when the temperature sensor is out of order. Corus PTZ manages three temperature alarms: a temperature low threshold alarm a temperature high threshold alarm a temperature sensor failure alarm When a temperature alarm occurs: the alarm icon and the 'T' icon are displayed (blinking during alarm is active) the incrementing of the main converted index is stopped if the alarm is due to a temperature sensor failure : temperature, compressibility and conversion factor are set to "not-available" on the display the total converted counter is incremented based on the back-up temperature value (if existing) the on/off outputs activated as alarm outputs are switched 'on' , if the corresponding alarm was configured for alarm output the corresponding alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.3 LF coherence alarm This alarm can be enabled or disabled by programming. The user can program a number of pulses (Np) and a duration (Dp). If the difference between the number of pulses on input LF1 and input LF2 is higher or equal to Np during a period Dp expressed in days (see 4.2), Corus PTZ generates an alarm This alarm is not metrological, meaning that it does not impact the management of the unconverted and converted indexes. When the alarm occurs: the alarm icon displayed
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
19 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
the on/off outputs activated as alarm outputs are switched 'on' , if the LF coherence alarm was configured for alarm output the LF coherence alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.4 Tamper alarm, on/off1 alarm, on/off2 alarm These alarms can be enabled or disabled by programming. When enabled, the tamper input and the on/off inputs can be set as normally open or normally close (see 4.1 and 4.3). Then, when Corus PTZ detects that an input is not in its normal state, the corresponding alarm is generated. When such an alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.5 Conversion factor alarm If this function is activated, Corus PTZ generates this alarm when the computed conversion factor gets out of a programmed range (Cmin ; Cmax). This alarm is not metrological and is dedicated to the control of the whole metering chain. Corus PTZ manages two conversion factor alarms: conversion factor low threshold alarm conversion factor high threshold alarm When a conversion factor alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the conversion factor alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.6 Converted consumption alarm Corus PTZ sets this alarm when the converted consumption during a given interval is higher than a programmed threshold. The interval can be selected among: the current database interval the ongoing hour the ongoing day the ongoing month. When the alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.7 Flow-rate alarms Corus PTZ manages four flow alarms: unconverted flow low threshold alarm unconverted flow high threshold alarm converted flow low threshold alarm converted flow high threshold alarm
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
20 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Every time the unconverted and converted instantaneous flows are calculated, their values are compared to four thresholds, that are programmable by the user. If the function is activated, an alarm of the above list is set if the corresponding flow-rate gets higher or lower than the threshold. When such an alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the alarm is set into the 'ALARM' menu and is stamped into the event log 6.2.8 Battery alarm Each 24 hours , the internal battery counter is decreased of one day. When the counter reaches 10% of the nominal battery life (about 6 month (182 days) for a 5 years battery life), the battery alarm is generated. When changing the battery, the battery counter has to be re-programmed so as to remove the battery alarm. When the battery alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the alarm is set into the 'ALARM' menu and is stamped into the event log The battery alarm is not metrological, meaning that when the battery alarm occurs, Corus PTZ continues to works up to the moment when the battery is fully discharged.
6.2.9 External power supply alarm When Corus PTZ is supplied through external power, it is able to detect a main cut. Then, this alarm is set as long as the external supply is not present. During the main cut, the internal backup battery will ensure the total functioning of Corus PTZ and the battery counter will be decreased with the same management described in the "battery alarm" chapter. When such a alarm occurs: the alarm icon displayed the on/off outputs activated as alarm outputs are switched 'on' , if the alarm was configured for alarm output the alarm is set into the 'ALARM' menu and is stamped into the event log
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
21 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Select the type of alarm to be resetted : Metrologic (P or T) and/or Non metrologic Click on Prog button
Note 1 : it is not possible to reset an alarm in progress, except the Coherence alarm and the Consumption threshold alarm Note 2 : The Reset alarm action is allowed according the data access rights that has been programmed in the CORUS (switches status)
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
22 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
USER INTERFACE
Corus PTZ features a graphic liquid crystal display and a five keys keyboard. The five keys allows to move into the various menus as described below. There displayed sequence is based on five main menus : INDEX, VALUE and ALARM menus are always displayed. DATA and CONFIG menus can be displayed or not according configuration.
INDEX VALUE ALARM DATA C ONFIG
Also, Corus PTZ manages the following icons: the turbine icon is refreshed every second and is: on if any pulse has been metered since the last screen refresh off else the bell icon: blinks when any alarm is active is on when any alarm is memorized but none is active is off when all alarms are off (neither active nor memorized) the pressure icon: blinks when any pressure alarm is active is on when any pressure alarm is memorized but none is active is off when all pressure alarms are off (neither active nor memorized) the temperature icon: blinks when any temperature alarm is active is on when any temperature alarm is memorized but none is active is off when all temperature alarms are off (neither active nor memorized) the phone icon is: on when any communication is ongoing off else the plug icon: is off when CORUS is used in battery operating mode is on when CORUS is used in external supply mode and main is present blinks when CORUS is used in external supply mode and main is not present the inner bar graph of the battery icon is set according to the remaining battery life time ratio : is on when CORUS is used in battery operating mode is off when CORUS is used in external supply mode blinks when the battery alarm is active
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
23 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
24 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
7.4.2 Memorized alarms The memorized alarm submenu displays the list of all memorized alarms. Using the up/down arrow and the OK keys, it is then possible to get more details about a given active alarm (Start and End time-stamping) 7.4.3 Under alarm counters This submenu displays the under alarm unconverted counter and the total converted counter. 7.4.4 Alarms reset This submenu allows to reset all memorized alarms and/or the under alarm counters (according to the status of the prog switch for metrological alarms)
The access to the modification of data is related to the access rights and to the position of the switches (Programming and Customer).
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
25 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
INDEX MENU
Index menu
INDEX VALUE ALARM DATA CONFIG
contrast+
Unconverted volume :
19348725.000 m3
Converted volume :
config menu
value menu
24284651.283 Nm3
Date / Time and Versions menu
INDEX VALUE ALARM DATA CONFIG
contrast-
08/01/2003 17:07:19
CC : 07 CPU: Metrol:
Status menu
INDEX VALUE ALARM DATA CONFIG
config menu
Status
value menu
config menu
Index menu
value menu
config menu
value menu
Index menu
Index menu
Index menu
Index menu
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
26 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
VALUE MENU
Value menu
INDEX VA LUE A LA RM DA TA CONFIG
P T Zb/Z C Qm Qb Bat
Graph
INDEX
= = = = = = =
15.698 bar -13.5 C 1.0035 5.6454 152.5 m3/h 153.9 Nm3/h 250 days
previous item
Index menu
s how Graph
Alarm menu
next item
VA LUE
A LA RM
DA TA
CONFIG
4.2
indexes menu
alarms menu
4.0 P (bar)
4.025
Instantaneous value
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
27 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
ALARM MENU*
Alarm menu
INDEX VALUE ALARM DATA CONFIG
Reset
INDEX VALUE ALARM DATA CONFIG
Active alarms
1/2
previous alarm back to alarms menu see details for selected alarm next alarm back to alarms menu
upper item back to alarms menu reset selected item lower item back to alarms menu
Confirmation screen
INDEX VALUE ALARM DATA CONFIG
Pressure sensor failure start: 14/08/2002 16:03:41 end : --/--/---- --:--:-Active alarms 1/2
INDEX
VALUE
ALARM
DATA
CONFIG
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
28 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
DATA MENU
Data menu
INDEX VALUE ALARM DATA CONFIG
Database: hourly log Hourly Daily log Monthly log Interval log Event log Parameters log
Date selection
INDEX VALUE ALARM DATA CONFIG
upper menu item alarms menu enter selected submenu lower menu item config menu
previous date back to database menu display records on date next date back to database menu
1/60
16:00 > Now 15:00 > 16:00 14:00 > 15:00 13:00 > 14:00 12:00 > 13:00 11:00 > 12:00
14/08/2002
Data
INDEX VALUE ALARM DATA CONFIG
previous record back to date selection choose selected record previous record back to date selection
2/24
scroll up
scroll down
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
29 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
CONFIG MENU
Config menu
INDEX VALUE ALARM DATA CONFIG
Volume
INDEX VALUE ALARM DATA CONFIG
INDEX
VALUE
ALARM
DATA
CONFIG
000185.000
Selection with up and down keys + OK Selection of the digit with left and right keys Adjust of value with up and down keys
OK for validation
Metrology
INDEX VALUE ALARM DATA CONFIG INDEX VALUE ALARM DATA CONFIG
Pb : 1.01325 bar Tb : 273.15 K Gas rel. density : 0.57000 C02 : 1.8 % N2 : 0.6%
0.57000
Selection of the digit with left and right keys Adjust of value with up and down keys
INDEX VALUE ALARM DATA CONFIG
OK for validation
OK for validation
Selection of the digit with left and right keys Adjust of value with up and down keys
Battery
OK for validation
INDEX
VALUE
ALARM
DATA
CONFIG
1.000 m3
Selection with up and down keys + OK Selection of the digit with left and right keys Adjust of value with up and down keys
OK for validation
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
30 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
8.1 Fixing
The enclosure of Corus PTZ intends four lateral holes (diameter 5.2mm) for a wall-mounting or for a mounting on a special plate. Following the installation procedure, Corus PTZ has to be carefully closed using the four screws placed on each corner. All cable glands have moreover to be tightened enough. These two actions are mandatory to achieve a correct water tightness of the enclosure.
J1 T sensor
Shield Shield Red White White Red
J3 Meter
Brown Shield Grey
1 2 3 4 5
1 2 3 1
J5
2 3 4 5 6 7 8
IN 2 OUT 1 OUT 2+ OUT 2 OUT 1+ IN 2+
Modem (opt.)
T sensor
P sensor
RS232
J6
9 10
EXT EXT+
1 2 3 4 5
White Brown Yellow Pink Grey
6
Green
1 2 3
White Yellow Pink
4
Green
1 2 3
TxD RxD DTR
4 5
+6V +0V
IN 1+ IN 1 -
P sensor J2
Meter J4
On / Off Inputs
RS 232
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
31 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
8.2.1 Pressure and temperature sensor J1.1 J1.2 J1.3 J1.4 J1.5 J1.6 8.2.2 LF cable J3.1 J3.2 J3.3 Tamper + (brown) Tamper (gray) shield (LF cable) J4.1 J4.2 J4.3 J4.4 8.2.3 On/off inputs, on/off outputs, external power supply J5.1 J5.2 J5.3 J5.4 J5.5 J5.6 J5.7 J5.8 J5.9 J5.10 8.2.4 RS232 interface J6.1 J6.2 J6.3 J6.4 J6.5 TxD RxD DTR Supply+ Supplyon/off in1+ on/off in1on/off in2+ on/off in2on/off out1+ on/off out1on/off out2+ on/off out2ext.supply+ ext.supplyLF1 + (yellow) LF1 (white) LF2 + (pink) LF2 (green) shield (T sensor) red (T sensor) white (T sensor) red (T sensor) white (T sensor) shield (P sensor) J2.1 J2.2 J2.3 J2.4 J2.5 J2.6 pink (P sensor) yellow (P sensor) gray (P sensor) brown (P sensor) white (P sensor) green (P sensor)
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
32 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Each LF cable binder plug intends two(2) holes allowing to seal and link the CORUS cable to the meter installation.
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
33 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
8.4.1 Internal battery Corus PTZ is delivered with a 19 A.h D-size lithium battery that provides an autonomy of 5 years in average conditions. This battery includes all protections required by intrinsic safety and cannot be changed for a different type. When the battery reaches the end of its life, it has to be replaced according to the following procedure that ensures a non-stop operation of the product: do not provoke short-circuits on the new battery : it would be definitively damaged check the voltage of the new battery : it should be above 3.6V open the cover of the box connect the new battery on the free battery connector (J7 or J8) disconnect the old battery and remove it from the battery support put the new battery into the battery support reprogram the battery life to its nominal value (1825 days) close the case and check Corus PTZ 8.4.2 External power supply Corus PTZ can also be supplied by an external intrinsic safety associated module from: a 220 VAC mains a 24 VDC mains The corresponding module has to be connected to the right hand side of the terminal J5 (J5.9 and J5.10). The converter must then be configured into the 'external power supply' mode. For safety reasons, it is strictly forbidden to use other modules than those specified by 'Actaris'.
8.4.3 Autonomy The table below shows indicative (see notes) autonomy of the CORUS in years when using the battery mode, according the 3 main parameters : Acquisition period, Retransmissions, Communication
F = 0,1 Hz
F = 0,5 Hz
F = 1 Hz
F = 2 Hz
Comm. Duration
15min./ month 15min./ week 15min./ month 15min./ week 15min./ month 15min./ week 15min./ month 15min./ week 15min./ month 15min./ week 15min./ month 15min./ week
corus_guid
1 1 3,6 3,6 5,4 5,3 6,4 6,3 7,1 6,9 8,0 7,8
1 1 3,2 3,1 4,4 4,4 5,1 5,0 5,6 5,4 6,1 5,9
0,9 0,9 2,7 2,7 3,6 3,6 4,1 4,0 4,3 4,2 4,7 4,6
0,8 0,8 2,1 2,1 2,7 2,6 2,9 2,9 3,0 3,0 3,2 3,1
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
on 10/23/03
34 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
Note 1 : The values provided in this table correspond to typical values in average conditions of use ; They are calculated with a 30% margin to take in account the possible variations of operating conditions that could impact the consumption of the product ( temperature , humidity, self-discharge of the battery ,.) Note 2 : The frequency of retransmissions indicated in the table correspond to average frequency on the 2 outputs, when both channels are configured for pulses. Note 3 : In case of activation of Digital output as ALARM output , the consumption of the device can be impacted, specially in Standard mode for which the output is activated as long as the alarm is active. Then, it is recommended to use preferably the limited mode or to use CORUS with an external power supply module if Standard mode is required.
8.5 Programming
To program/modify parameters protected by the programming. Switch , the following procedure has to be followed : Open the CORUS Remove the seal of the white metrologic cover, placed on the left part of the I/O board Put the programming switch On Program the required parameters (Keyboard or communication) Put the programming switch Off Place the metrologic cover and seal it Close the CORUS To program/modify parameters protected by the Client switch , the following procedure has to be followed : Open the CORUS Put the Client switch On Program the required parameters (Keyboard or communication) Put the Client switch Off Close the CORUS
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
35 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2
SAFETY INSTRUCTIONS
9.1 General
The CORUS gas volume converter is approved according to 94/9/CE directive (ATEX) relative to introduction of material in explosive atmosphere area. The respect of this directive is mandatory (from July,1st 2003 ) and is now included in the 'CE' marking. Then, 'CE' marking of the CORUS intends now conformity with following directive : 94/9/CE (ATEX) and 89/336/CE (EMC)
Caution : The battery of the CORUS includes all protections required by Intrinsic safety. Then, It is strictly forbidden to replace the battery unit by any battery other than the one specified by 'Actaris' ( reference : SL2780 de Sonnenschein or TD5930 de Tadiran ) ! To prevent any damage, following operations are recommended to limit electrostatic discharges on the enclosure of the CORUS : clean the front-panel only with a damp heat the person carrying out the installation can discharge himself/herself by touching the potential equalisation line
Title : Owner :
FR:PTZ/MKT USER_GUID Manuel utilisateur V2 export anglais Hardware_literature Andre Laborde RELEASED
Copyright Actaris 03
corus_guid
on 10/23/03
36 / 36
Viewed by Andre Laborde (10/23/03) .
D0216877
AA
v2