0% found this document useful (0 votes)
343 views

Teslameter CYHT201-User's Manual

The CYHT201 Gaussmeter is an updated version of the CYHT20 that can measure magnetic fields with high resolution from 0-200mT and 0-2000mT. It uses a Hall effect sensor and offers features like peak hold, automatic range selection, and polarity display. It is portable, easy to use, and suitable for quick checks and comparisons between measurements.

Uploaded by

ecoprima
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
343 views

Teslameter CYHT201-User's Manual

The CYHT201 Gaussmeter is an updated version of the CYHT20 that can measure magnetic fields with high resolution from 0-200mT and 0-2000mT. It uses a Hall effect sensor and offers features like peak hold, automatic range selection, and polarity display. It is portable, easy to use, and suitable for quick checks and comparisons between measurements.

Uploaded by

ecoprima
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

The Gaussmeter CYHT201 is a new generation of the Gaussmeter

CYHT20. It can be used to measure DC/AC magnetic field strength of


permanent magnet materials, motors, speakers, magnetic sensors/
transducer and other machines and instruments etc. with high resolution.

1) Characteristics
Digital Gauss/Tesla Meter - Wide measuring range and high resolution
- A low-cost measuring device, which is easy to operate, portable
CYHT201 -
and convenient to handle and store.
Ideal for quick quality checks and comparative measurements,
with built-in polarity display.
User’s Manual
2) Technical Data

Measuring ranges: 0~200mT and 0-2000mT


Basic accuracy: DC: ±2.0%, AC: ±5.0%
Resolution: DC x1: 0.00 ~ 200.00mT, 0.01mT
DC x10: 0.0 ~ 2000.0mT, 0.1mT
AC x1: 0.00 ~ 200.00mT, 0.01mT
AC x10: 0.0 ~ 2000.0mT, 0.1mT

Measuring magnetic field: DC/AC (static & dynamic 10Hz ~ 200Hz)


Functions: Peak hold, Max hold,
automatic range Gs/mT selection
N/S pole display for DC measurement
Automatic probe zero adjustment

ChenYang Technologies GmbH & Co. KG Display: 4 ½ LCD


Display Unit: mT/Gs (1mT=10Gs)
Ambient temperature: +5°C ~ +50°C
Storage temperature: -20°C ~ +70°C
Markt Schwabener Str. 8 Relative humidity: 20% ~ 80%
85464 Finsing, Germany Power supply: +9V alkaline, block battery
Tel. +49-(0)8121-2574100 Dimensions: 160mm x 88mm x 36mm
Weight: 300g
Fax: +49-(0)8121-2574101
Email: [email protected]
http://www.chenyang-gmbh.com 3) Accessories

1. +9V DC power supply connecting to 220V AC, 1pc


2. +9V battery, 1pc
2
3. CYTP-T15A: transverse probe 1.5x 4 x 40mm, 1pc According to the Hall Effect, a voltage can be measured at right angle to
4. Adapter,1pc the current path when a conductor or semiconductor with current flowing
in one direction is introduced perpendicular to a magnetic field. The Hall
voltage can be calculated from:

VH = k H I H B

Where: VH: Hall voltage in volts


B: the applied field in Gauss
4) Special probes k H: sensitivity of the element in volts/Gauss
I: bias working current in amperes
CYTP-T08A: transverse probe 0.8 x 3 x 40mm
The initial use of this discovery was for the classification of chemical
samples. The development of indium arsenide semiconductor compounds
in the 1950's led to the first useful Hall Effect magnetic instruments. Hall
Effect sensors allowed the measurement of DC or static magnetic fields
CYAP-D60A: axial probe Ø6 x 40mm with requiring motion of the sensor.

6) Measuring Method

The magnetic lines of the measured magnetic field should perpendicularly


5) Measuring Principle pass through the Hall Effect element of the Hall probe.

The Gauss/Tesla meter works with a Hall Effect sensor/probe. There are The sensing plan of the Hall
two kinds of Hall probes: transverse and axial probes, which are used for sensor/probe should be
different magnetization directions. positioned perpendicular to the
magnetic field

Measurement of magnetic field


in a space or gap

Electric
Charge
Vertical
Put the concave side, i.e. the side with a small circle mark of the probe on
the surface of the measured magnet or at the measuring point of a
Hall Effect and its Electrical Parameters
3 4
magnetic field carefully. Front Panel
Convex

Measurement of
surface flux density
of a magnet
DC Magnetic field

AC Magnetic field

Measurement of AC
magnetic field
generated by AC
current
CYHT201

Incorrect use of Hall probe,


too large measuring force,
Easy damage the Hall probe!!

CYHT201 Digital
7) Part and Functions Gauss/Tesla Meter

AC Mode mark Peak hold

Pole display (DC)

1: Socket-outlet with 5 pins 2: LED display


3: Peak max/min hold 4: AC/DC Mode
5: Power switch 6: Unit select
Measuring value Display unit 7: Zero/peak reset 8: measuring range

5 6
Back Panel
Hall sensor/probes
Protective tube

Concave
Transverse probe

Power
Socket

Protective tube

Concave
Axial probe
Battery

Compartment

1) Socket-outlet: to connect the Hall sensor/probe to the measuring


instrument
2) LCD display: to display the field strength and pole direction (“N” 9: Plug of Hall probe 10: Measuring circle mark
north pole, “S“ south pole) and ~ AC mode mark etc. 11: Measuring contact position
3) Peak max hold: to display and hold the peak/max value
4) AC/DC Mode: to select the measurement of AC or DC magnetic field
5) Power switch: to switch ON/OFF the measuring instrument Hall probe CYTP-T08A
6) Unit select: to select the measuring and display unit
(Gauss or mT)
7) Zero/peak reset: to reset the measuring value and peak mode. Using this side (without
8) Range select: to select the measuring range 0-200mT or soldered connection) for
0-2000mT measurement
9) Plug of Hall probe: to connect the Hall probe to the measuring
instrument
10) Measuring circle mark: the side with this mark is the measuring side Don’t use this side (with
of the Hall sensor. You should use this side to measure the surface soldered connection) for
magnetic field of permanent magnet. This side should be positioned measurement
perpendicular to the magnetic field
7 8
8) Measuring Procedure

1) Install the +9V battery to the battery compartment or connect the +9V
power supply to the measuring instrument
2) Connect the Hall sensor/probe to the measuring instrument
3) Switch on the power of measuring instrument by pressing button (5), Unit: mT Unit: Gs
LCD display shows 0.0mT
7) Reset Gaussmeter. Keep the Hall probe faraway from magnetic
field, LCD display shows zero after pressing button (7) :

4) Select measuring range by pressing the button (8), the measuring


range changes between 0-200mT and 0-2000mT as follows:

0-2000mT 0-200mT

5) Select AC/DC Mode by using the button (4), the display shows the
following DC or AC measuring mode:

DC magnetic field AC magnetic field


Note: You must reset the Gassmeter before you start a new
“N” north pole, “S“ south pole for DC magnetic field measurement after you have changed the measuring range (8) and
AC/DC Mode (4).
6) Select unit by pressing (6), unit changes between Gs and mT
8) Select peak hold. You can select peak holding mode or normal
measuring mode by using button (3).

9 10
9) Warranty

Measuring instrument: 12 months


Hall sensor/probe: no guarantee. However we offer you
Replacement for reduced price (10%
Normal measuring mode Peak holding mode discount)

9) Take off the protective tube of the Hall sensor/probe, position the 10) Service
measuring circle mark (10) on the surface of the measuring object
(such as permanent magnet), and read the display value (measuring Please contact us for technical questions, repairing and
value and pole display “N” or “S“).
replacement etc:
Note: the measuring circle mark (10) is measuring point of the Hall
sensor. The pole is N pole if the display is “N” when this mark orients
to the measuring object. ChenYang Technologies GmbH & Co. KG
10) Reset peak hold mode. Under the peak holding mode the display Markt Schwabener Str. 8
changes only when the actual measuring value is larger than the last 85464 Finsing, Germany
peak value (displayed). Therefore you must reset the peak holding Tel. +49-(0)8121-2574100
mode by using button (7) if you need to measure smaller magnetic
Fax: +49-(0)8121-2574101
field than the peak value. The device works still in peak holding mode
after resetting.
Email: [email protected]
http://www.chenyang-gmbh.com
Sample: last peak value: 1500mT, actual peak value 800mT after
reset the peak holding mode

11) After the measurement please put the protective tube on the Hall
probe in order to protect the Hall element and switch off the power
12) The Hall probes delivered are compatible. The measuring accuracy
under using other changed Hall probes is ±2%.

11 12