0% found this document useful (0 votes)
1K views

Concrete Mix Design

This document provides specifications for three types of concrete mix designs: 1) Normal weight concrete for structural elements with cement contents ranging from 380-450kg/m3 and water-cement ratios of 0.35-0.45. 2) Blinding concrete for non-structural elements with lower cement contents of 280-320kg/m3 and higher water-cement ratios of 0.35-0.6. 3) Cement sand screed for waterproofing protection with cement contents of 280-350kg/m3 and water-cement ratios of 0.5-0.65.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

Concrete Mix Design

This document provides specifications for three types of concrete mix designs: 1) Normal weight concrete for structural elements with cement contents ranging from 380-450kg/m3 and water-cement ratios of 0.35-0.45. 2) Blinding concrete for non-structural elements with lower cement contents of 280-320kg/m3 and higher water-cement ratios of 0.35-0.6. 3) Cement sand screed for waterproofing protection with cement contents of 280-350kg/m3 and water-cement ratios of 0.5-0.65.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

ASCON DESIGN DEPARTMENT TECHNICAL LIBRARY

Concrete Mix Design


1.1 Normal Weight Concrete
Grade C30/20, C40/20, C50/20
Purpose Concrete for Column, Beam, Slab and other Structural elements

Specification
Description Allowable Limit Optimum Value Remarks
Cement Content 380 450 kg/m3 410 kg/m3 MSRC for
substructure and OPC
for super structure. Cement & GGBS
composition
45:55 to 30:70 40:60
Slump 150 250 mm 200 mm
Cement & Aggregate
ratio
1:4.5 1:4.5
Coarse Aggregate &
Fine aggregate ratio
55:45 to 75:25 55:45
Chloride Content Up to 0.2% 0.08%
Sulphate Content Up to 4% 1.2-1.6%
Water cement ratio 0.35 0.45 0.40
Admixture Name &
Qty
SP495 / 4.0-8.5 litr Refer manufacturers
recommendation

Project References
Project SGD Non Process Building Borouge Innovation Centre Summit Tower
Supplier Xtramix, Transgulf, Dodsal



ASCON DESIGN DEPARTMENT TECHNICAL LIBRARY


1.2 Blinding Concrete
Grade C20
Purpose Blinding, Pavements and All Non structural elements

Specification
Description Allowable Limit Optimum Value Remarks
Cement Content 280 320 kg/m3 300 kg/m3 MSRC for
substructure and OPC
for super structure. Cement & GGBS
composition
45:55 to 30:70 30:70
Slump 150 250 mm 200 mm
Cement & Aggregate
ratio
1:6.6 1:6.6
Coarse Aggregate &
Fine aggregate ratio
55:45 to 75:25 55:45
Chloride Content Up to 0.2% 0.08%
Sulphate Content Up to 4% 1.2-1.6%
Water cement ratio 0.35 0.6 0.5
Admixture Name &
Qty
SP495 / 4.0-8.5 litr Refer manufacturers
recommendation

Project References
Project SGD Non Process Building Borouge Innovation Centre Summit Tower
Supplier Xtramix, Transgulf, Dodsal



ASCON DESIGN DEPARTMENT TECHNICAL LIBRARY



1.3 Cement Sand Screed
Grade C20
Purpose Protection Screed Over Waterproofing, etc

Specification
Description Allowable Limit Optimum Value Remarks
Cement Content 280 350 kg/m3 330 kg/m3
Cement & GGBS
composition
45:55 to 30:70 30:70
Slump 150 250 mm 200 mm
Cement & Aggregate
ratio
1:3 to 1:5 1:5
Coarse Aggregate &
Fine aggregate ratio
55:45 to 75:25 55:45
Chloride Content Up to 0.2% 0.08%
Sulphate Content Up to 4% 1.2-1.6%
Water cement ratio 0.5 0.65 0.57
Admixture Name &
Qty
SP495 / 2.0-4.5 litr SP495 / 2.0-4.5 litr Refer manufacturers
recommendation

Project References
Project SGD Non Process Building Borouge Innovation Centre Summit Tower
Supplier Xtramix, Transgulf, Dodsal