Condensate Pot
Condensate Pot
I = u.S1 _g J _
p
L
-p
g
p
L
]
Where
L
and
g
are condensate and steam densities respectively.
Vapor Balancing Line
The purpose of vapor balancing line, as its name implies, is to equalize the pressure of condensate pot with heating
equipment, prevent vapor blanketing the condensate pot and minimize the static head difference between liquid level in the
heat exchanger and corresponding level in pot (H
2
).
Vapor balancing line is not going to pass any specific flow rate; hence any size between 1 to 3 would be enough for this
purpose.
Condensate Line Piping Arrangement
Since heat exchanger flooding may create sub-cooled condensate, it is recommended to locate the condensate inlet close to
pot bottom TL so that sub-cooled condensate exits out of the bottom of the pot without reaching the liquid surface (NLL) as
shown in Figure 3. With adequately sized pressure balancing line, pot liquid surface is kept hot, and the pot pressure will
remain at vapor pressure of hot liquid. As long as the liquid in the upper part of the pot is not agitated and does not contact
the sub-cooled condensate, the flow of steam through a typically 1 equalizing line is sufficient to compensate system heat
losses to ambient and heat transfer from hot surface to the sub-cooled condensate.
Another alternative is to connect the heat exchanger condensate line to the pot condensate outlet line as depicted in Figure 2.
This arrangement may result in slightly longer pipe, higher pressure drop and subsequently bigger H
2
.