This structural survey summarizes the condition of a three bedroom farmhouse. The roof needs repairs, with the lower roofs and chimneys in poor condition. The exterior walls are deteriorating with cracking, bulging and missing bricks requiring rebuilding. Windows and doors are damaged with infestation. Internally, the ceilings, walls, floors and joinery are all damaged and in need of replacement due to damp issues throughout the property. The drainage and plumbing systems are not functioning properly, and the electrical, heating and insulation all require full replacement to meet current standards. In summary, the property is in very poor structural condition and requires extensive renovations.
This structural survey summarizes the condition of a three bedroom farmhouse. The roof needs repairs, with the lower roofs and chimneys in poor condition. The exterior walls are deteriorating with cracking, bulging and missing bricks requiring rebuilding. Windows and doors are damaged with infestation. Internally, the ceilings, walls, floors and joinery are all damaged and in need of replacement due to damp issues throughout the property. The drainage and plumbing systems are not functioning properly, and the electrical, heating and insulation all require full replacement to meet current standards. In summary, the property is in very poor structural condition and requires extensive renovations.
Produced for free download by Edgeworth Street Ltd., Chartered Building
Surveyors.
This document is an example of a structural survey, designed to demonstrate how a a structural survey is conducted. You may use this document in any way you wish, but it must not be republished for display or download on any web site or Intranet without the prior written agreement of Edgeworth Street Ltd., the original author and copyright owner. If you need assistance with commercial building surveys, please contact Robert Street at the address below:
Edgeworth Street Ltd 184 Haslucks Green Road Solihull West Midlands B902LN Tel: 0121 733 8686 Fax: 0121 733 8668 Mobile: 07967 829025 Web: www.edgeworth-street.co.uk Email: [email protected]
We hope that this download example is what you were looking for. We have other example surveys available at our web site, but if you cant find what you are looking for, please let us know and well see if we can add it to the site, or provide you with a copy. Thank you for your interest in Edgeworth Street Ltd
Mr J Bloggs Our ref: The Farm The Green Telford T11 1AB
Dear Mr Bloggs
RE: THE FARM MAIN FARM HOUSE
1.0 INTRODUCTION
In accordance with instructions received from Mr Bloggs, we have carried out a Structural Building Appraisal Report on the subject premises.
The property comprises of a three bedroomed residential farm house which we understand to be held on a freehold basis by Mr Bloggs.
The property is constructed of traditional plain tiling on timber rafters falling to UPVC rainwater goods, with a mixture of structural facing brickwork and stonework. Joinery comprises of a mixture of UPVC windows and timber doors/frames. Floors are suspended timber variety to the upper floor with solid floors to the ground floor accommodation.
Internally the property consists of three upper bedrooms with ground floor accommodation comprising of two reception rooms, a kitchen, hall/stairway and utility area.
We would advise that no tests were carried out to any of the service installations or below ground drainage.
Any comments or reference to the mechanical or electrical elements are based on a visual inspection and/or on historical information obtained from Mr Bloggs.
Whilst our survey was thorough, it was not possible without causing damage to inspect those parts of the property that were covered or unexposed at the time of survey and therefore, we are unable to guarantee that such parts are free from defects.
Our site visit was made on Friday 15 April 2005, the weather being dry and cloudy.
The exact age of the property is not known, however, the premises are said to be built in the Duke of Sutherland vogue and therefore are considered to be pre- 1900.
2.0 BUILDING EXTERIOR
2.1 Roofs/Roof Structure/Rainwater Goods
Traditional plain tiling on timber rafters and purlins is provided, falling to UPVC rainwater goods, with brick built, rendered chimney stacks.
The rainwater goods to the main roof are generally satisfactory although impeded. However, the rainwater goods to the single storey roofs are generally poor with areas impeded, broken and missing requiring remedial work.
The main roof has recently been re-tiled, however the lower roofs have not and are in poor condition. It was not possible to inspect the timber work beneath the tiling. However, there is evidence of some infestation requiring repair/replacement.
The chimney stacks appear to have been partly rebuilt and rendered. However, there is evidence of cracking where further substantial repair may be required.
2.2 External Walls and Cladding
External walls comprise of a mixture of stonework and structural facing brickwork with arched openings.
A stone built single storey extension is provided to the rear of the accommodation with areas of considerable damage/settlement and rebuilding is required.
1 no. gable is partly constructed of stone and there is evidence of cracking and misaligned brickwork.
There is bulging brickwork to the front elevation together with cut back reveals causing the arches above to drop and evidence of cracking requiring substantial rebuilding/remedial work.
The main gable has evidence of considerable cracking and mis-matching brickwork together with former repair. There is still evidence of progressive movement requiring substantial rebuilding.
There is no damp course to the property and dampness is evident throughout.
Many of the facing bricks and joints have perished and spalled requiring substantial replacement and re-pointing.
The single storey extensions added have been poorly bonded with straight joints and some areas pulling away. Substantial repair is required.
2.3 External Joinery
Plastic windows are provided together with timber doors and frames.
Plastic windows have deteriorated with age and use and evidence of failed double-glazed units and cutting back of the existing reveals to facilitate fitting. Substantial alterations to the reveals will be required thus making the windows redundant.
The timber doors and frames have deteriorated with age and use and the neglect of maintenance and substantial timber infestation is noted. Replacement or substantial repair is required.
2.4 External Decorations
The external decorations have deteriorated with age and use and neglect of cyclical redecoration. Redecoration is required.
2.5 External Areas
Generally gravel/paving is provided. However, substantial ponding was noted due to the lack of adequate drainage.
3.0 BUILDING INTERIOR
3.1 Roof Voids
No access was afforded to roof voids and this is recommended in order that adequacy of insulation can be determined and a full inspection of the roof timbers undertaken.
3.2 Ceilings
The ceilings are generally decorated plasterwork and have suffered from unevenness and cracking throughout with areas loose and hollow areas. Substantial replacement and/or repair is required.
3.3 Internal Walls/Structures
The internal walls are generally stonework and/or brickwork with decorated plastered finish.
The internal walls have no damp course and dampness is prevalent throughout.
The plasterwork throughout has evidence of dampness, perishing loose and hollow areas and due to the lack of damp course and penetrating damp virtually complete re-plastering will be required.
The flues to the fireplaces are blocked and dampness is evident because of the same. Some fireplaces have been removed and parts missing in some rooms. Substantial replacement/remedial works is required.
3.4 Floors
The solid floors to the ground floor consist of a quarry tiled finish. However, the floors are considerably uneven with some areas having collapsed due to inadequate fill beneath. No damp proof membrane was noted in any of the floors and substantial replacement is required.
It is presumed that the vinyl tiles to the bathroom contain asbestos and it is advisable that these are removed by a licensed contractor when the floor is replaced.
Suspended timber floors are provided to the first floor. However, there is evidence of infestation requiring substantial replacement and/or treatment.
3.5 Internal Joinery
The internal joinery is generally timber doors in timber frames with timber architraves and skirtings where applicable.
The internal joinery has deteriorated with age and use with some areas of infestation and substantial repair and/or replacement and treatment is required.
3.6 Internal Decorations
The internal decorations have deteriorated due to the conditions which prevail in the premises and complete redecoration is required.
3.7 Sanitary and Welfare Accommodation
The bathroom is provided to the ground floor and although part operational it is understood that the plumbing system is problematic and the drainage system does not function correctly.
A kitchen facility is provided to the ground floor, however, has deteriorated with age and use and requires complete refurbishment.
4.0 OTHER ISSUES
4.1 Drainage
The foul water drainage system falls to a septic tank.
The drainage system has collapsed in many areas and the septic tank is beyond economical repair. Total replacement of the foul water drainage system is required.
The storm water system falls to soakaways.
The soakaways do not function properly allowing considerable flooding and ponding adjacent the premises which may indeed contribute to the structural movement. Complete replacement of the storm water drainage system and soakaways should be undertaken.
4.2 Electrical Installation
The electrical installation does not comply with current regulations and there are areas of damp affected fittings. Complete replacement of the electrical installation is required.
4.3 Heating System
A redundant heating system is provided and non-operational.
Complete replacement of the heating system is required.
4.4 Mains Water
Mains water is provided to the premises. However, the plumbing system is said to be troublesome and substantial repair/improvement is required.
SUMMARY AND CONCLUSION
Having given due regard to the age, nature and construction of the premises, the general structured condition thereof is considered to be very poor. Many defects were noted and concerns raised and substantial remedial works are required.
It is understood that the owner would like to extend and improve the property. However, from our survey we feel it may be uneconomically viable to undertake repairs and extensions to meet the standard required and therefore consideration should be given to complete demolition and the provision of a complete new structure. SCHEDULE OF PHOTOGRAPHS
Photo No. Description 1. View of house 2. Perished brickwork 3. Poorly bonded brickwork 4. Perished brickwork 5. Perished brickwork 6. Perished brickwork and poor waste disposal 7. Deterioration to roof 8. Poor flashing to roof 9. Structural damage to stonework 10. Structural damage to stonework 11. Spalling stonework 12. Deterioration and movement to gable ends 13. Dilapidated single storey extension requiring rebuilding 14. Enlarged reveals 15. Cracking above arch after enlarged reveals 16. Cracking above arch 17. Cracking above arch 18. Deterioration to brickwork 19. Cracking above arch 20. Cracking above arch 21. Cracking of previous repair to gable 22. Mis-matching and cracked brickwork to gable 23. Mis-matching and spalled brickwork 24. Absence of damp course 25. Evidence of dampness 26. Deterioration to floor 27. Deterioration and dampness 28. Deterioration and dampness 29. Deterioration to floor and dampness 30. Evidence of dampness 31. Deterioration to internal premises 32. Collapsed floor 33. Evidence of dampness 34. Evidence of dampness 35. Collapsed floor 36. Evidence of dampness 37. Evidence of dampness 38. Missing fireplace and blocked flue 39. Evidence of dampness 40. Evidence of dampness 41. Evidence of dampness 42. Cracked ceiling
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
4.0 CAVEATS
We have assumed that all necessary permanent planning and other permissions, approvals and consents, have been obtained for the construction and current use of the premises, and that there are no outstanding enforcement or other notices. Non compliance with any statute or statutory regulations affecting the premises has not been established. This survey is in respect of the buildings, construction, repair and maintenance; we have not considered nor investigated any aspects of the premises which are likely to be affected by mining or tunnelling operations, or are likely to be affected by current environmental legislation. We have not instigated nor carried out searches with the National Coal Board or prepared an environmental audit of the premises drainage or land. We have not inspected woodwork or other parts of the structure which are covered, unexposed or inaccessible and we are therefore unable to report that any such part is free from rot, beetle or other defects or to confirm the adequacy of any structural element or foundation, nor have we surveyed or tested the soil or ground conditions. The presence or absence of high alumina cement, calcium chloride, asbestos or permanent woodwool shuttering, fibre reinforced concrete, alkali silica reaction, sea dredged aggregates or any other deleterious materials within the premises has not been determined. We have not carried out detailed examinations or testing of the ventilating, heating, cooling, electrical, drainage or mechanical services installations. We have not been able to ascertain whether or not any structural repairs have been carried out including timber treatment, underpinning and strengthening, nor have we determined whether or not any guarantees exist. We have not been able to ascertain whether the property has ever been flooded or is likely to be affected in the future. We have not been able to ascertain the existence of any concealed access hatches or voids. We have not been able to ascertain any information in respect of any dispute or claim with neighbours or neighbouring property. We have made no investigations with any public Local Authority or statutory undertaker to ascertain whether or not there are any current notices or proposals affecting the property. We cannot confirm that any Building Services which incorporate electronic devices necessary for their proper functioning, and the software that operates such devices are Millennium Compliant, and this should be investigated and addressed separately. Any indication of cost in respect of any of the advice or items contained within this report, is given purely as guidance and should not be relied upon as being accurate; it is an opinion. An accurate cost of carrying out a particular item of work or the items of work described within the report, can be obtained but will entail considerable further work in detailing accurately the nature, scope and extent of the work and also will take further time. An exercise of this nature is beyond the scope and instructions of this report. This report is confidential to the parties to whom it is addressed and whose name appears at the beginning of this report. Neither the whole nor any part shall be disclosed to any other party and no reference thereto may be included in any circular or statement, nor published in any way, without the written approval of Edgeworth Street.
Signed.. R A Street MRICS FGIS MIMBM MCIOB For and on behalf of EDGEWORTH STREET LTD