80% found this document useful (10 votes)
4K views

Calibration Procedure For TUC-6 BLMS.

This document provides instructions for calibrating a test weight calibration (TUC-6) system using both a dead-load calibration procedure and an mV calibration procedure. The dead-load calibration procedure involves applying a test weight, zeroing the display, and then entering calibration load values. The mV calibration procedure involves entering a tare mV value with no load applied, applying a test weight, and then entering a calculated span mV value. Both procedures require navigating calibration menus using specified display keys.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
80% found this document useful (10 votes)
4K views

Calibration Procedure For TUC-6 BLMS.

This document provides instructions for calibrating a test weight calibration (TUC-6) system using both a dead-load calibration procedure and an mV calibration procedure. The dead-load calibration procedure involves applying a test weight, zeroing the display, and then entering calibration load values. The mV calibration procedure involves entering a tare mV value with no load applied, applying a test weight, and then entering a calculated span mV value. Both procedures require navigating calibration menus using specified display keys.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

X = 00,00 t

L =63,56 %
Password
Enter password :
Password
Enter password : Y
AnalogInput
Calibration
CALIBRATION_ MENU
RE-CALIBRATE? ->
DEAD-LOAD
0790
DEAD-LOAD
0000
CALIBRATION LOAD
2756 =>15000 d
SYSTEM DATA
MAINPROGRAM
CALIBRATION LOAD
0000 =>0000 d
Press & to enter the OFF LINE menu from the main
program.
Press to enter the PASSWORD menu
Enter 4 digit password which is stored in the configuration and
press to access the OFF LINE menu
If TUC shows Y the password is correct. Password is wrong
it shows N. If password is wrong again go to password menu
to enter the correct password. If password is correct press
to go to CALIBRATION menu.
Press to proceed the calibration. If the calibration menu in
bottom
To proceed the calibrations press
To terminate the calibration process press
Press to run the main programwhile main programmenu
in bottom line.
Press to go to main program.

Password
TUC DISPLAY ACCESS KEYS
DESCRIPTION
TEST WEIGHT CALIBRATION PROCEDURE FOR TUC-6 (BLMS)
Initially TUC shows some counts w. r .t old calibration,
accepting the DEAD LOAD by pressing the counts are
become zero. Before proceed the calibration ensure the belt is
empty & the load cell mechanismrepeatability is proper.
Press to precede the load calibration.
LHS counts (auto) w.r.t load cell mV & RHS counts determined
the calibration percentage. LHScounts will increase w.r.t to
increment of the mV from Tare mV. After study state of
counts enter the d counts in RHS w.r.t to calibration
percentage. Press to complete the calibration & close the
calibration menu.
Note: 1%calibration =20 d counts
Keep the test
weight on the bin
ISSUE: 1.0 - 10/03/17


mV CALIBRATION PROCEDURE FOR TUC-6 (BLMS)
X = 00,00 t
L =63,56 %
Password
Enter password :
Password
Enter password : Y
AnalogInput
Calibration
CALIBRATION_ MENU
RE-CALIBRATE? ->
TARE MV
2.125
Press & to enter the OFF LINE menu from the main
program.
Press to enter the PASSWORD menu
Enter 4 digit password which is stored in the configuration and
press to access the OFF LINE menu
If TUC shows Y the password is correct. Password is wrong
it shows N. If password is wrong again go to password menu
to enter the correct password. If password is correct press
to go to CALIBRATION menu.

PRESS 1 2 3 & press to enter the calculated mV as a
calibration.

Password
TUC DISPLAY ACCESS KEYS DESCRIPTION
Enter the Tare mV, which is generated by the load cell w.r.t
bin dead weight. Press proceed the span mV calibration.
Enter the calculated the span mV as per calculation table.
Press to quit the calibration menu.
SPAN MV
16.125
Press to proceed the calibration. If the calibration menu in
bottom
Press to go to main program.
SYSTEM DATA
MAINPROGRAM
Press to run the main programwhile main programmenu
in bottom line.