CLP Datasheet

The document describes a linear potentiometer called the CLP that provides precise potentiometric output over various measurement ranges from 0-1 to 0-11.5 inches. It has high linearity, repeatability and life expectancy. The CLP uses a conductive plastic sensor and operates like a voltage divider to provide position feedback with essentially infinite resolution at speeds up to 400 inches per second. It is enclosed in an aluminum housing with IP65 environmental sealing to operate in various conditions from -40 to 212 degrees Fahrenheit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views1 page

CLP Datasheet

The document describes a linear potentiometer called the CLP that provides precise potentiometric output over various measurement ranges from 0-1 to 0-11.5 inches. It has high linearity, repeatability and life expectancy. The CLP uses a conductive plastic sensor and operates like a voltage divider to provide position feedback with essentially infinite resolution at speeds up to 400 inches per second. It is enclosed in an aluminum housing with IP65 environmental sealing to operate in various conditions from -40 to 212 degrees Fahrenheit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Linear Potentiometer

CLP

Precision Potentiometric Output


Ranges: 0-1 to 0-11.5 inches [0-25 to 0-290 mm]
2.5K 11.6K ohms IP65
Specification Summary:
GENERAL
Full Stroke Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-1 to 0-11.5 in. (0-25 to 0-290 mm)
Output Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . voltage divider (potentiometer)
Linearity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 to 0.2% full stroke, see ordercode
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01 mm
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . essentially infinite
Life Expectancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 25 million cycles
Operating Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 inches (10 M) per second max.
Enclosure Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . aluminum
Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . conductive plastic linear potentiometer
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 7 oz. (87 - 197 g.), see ordercode
ELECTRICAL
Input Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5K to 11.6K ohms (20%), see ordercode
Recommended Maximum Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 VDC
Recommended Operating Wiper Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 1A
ENVIRONMENTAL
Enclosure Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
Environmental Sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-ring and felt shaft seal
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 to 212F
Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 10 Gs to 2000 Hz maximum
retracted mounting distance

1.06
[27]

.63 [16]

.59 [15] (square)

.20 [5]

Developed specifically to meet the needs of the auto


racing industry and proven in industrial applications,
Celescos CLP series position transducers offer unrivalled performance in terms of accuracy, repeatability, life expectancy and ease of mounting.
The combination of individually corrected conductive plastic elements and precious metal wipers provide a cost effective measuring system which can
operate effectively without being unduly influenced
by external environmental conditions.

mechanical stroke

retracted

electrical stroke

retracted

extended

extended
black

red
.192 [4.88]*
25
yellow
.32 [8]

.23 [6]

Measurement
Range

2 ft. [600 mm] long,


22 gauge electrical cable

All DIMENSIONS ARE IN INCHES [MM]


tolerances are 0.03 IN. [0.5 MM] unless otherwise noted
*tolerance = +.030 .000 [+0,76 -0,00]

1
25

2
50

3
75

4
100

6
150

8
200

10
250

11.5
290

in
mm

6.81
173

7.80
198

8.75
222

9.76
248

11.73
298

13.82
351

15.79
401

18.27
464

( 0.1) in
( 2 ) mm

1.12
28.5

2.11
53.5

3.09
78.5

4.08
103.5

6.04
153.5

8.13
206.5

10.10
256.5

11.55
293.5

( 0.02) in
( 0.5 ) mm

1.06
27.0

2.05
52.0

3.03
77.0

4.02
102.0

5.98
152.0

8.07
205.0

10.04
255.0

11.50
292.0

in
mm

Ordering Information:

Item Number
measurement range, in. [mm]:
resistance, (20%):
linearity, %:
weight, oz. [grams]:

CLP-25

CLP-50

CLP-75

1[25]
2.5K
0.2%
3.0[87]

2[50]
5.0K
0.2%
3.4[97]

3[75]
5.0K
0.2%
3.8[108]

CLP-100 CLP-150 CLP-200 CLP-250 CLP-290


4[100]
5.0K
0.2%
4.1[117]

6[150]
10K
0.1%
4.8[138]

8[200]
10K
0.1%
5.5[157]

10[250]
10K
0.1%
6.2[177]

11.5[290]
11.6K
0.1%
6.9[197]

Celesco Transducer Products, Inc.

20630 Plummer Street Chatsworth, CA 91311


tel: 800.423.5483 +1.818.701.2750 fax: +1.818.701.2799

celesco.com [email protected]

version: 4.0 last updated: December 12, 2006