0% found this document useful (0 votes)
418 views13 pages

Insulation Calc

The document provides specifications for insulation of industrial equipment, including a rectangular shape made of silicone coated steel with an operating temperature of 230°C, ambient temperature of 27°C, and cellular glass foam insulation that must not exceed 55°C. Calculations determine the required insulation thickness is 41.3mm for flat surfaces and 28.2mm for cylindrical surfaces of 100mm diameter oriented vertically.

Uploaded by

zamijaka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
418 views13 pages

Insulation Calc

The document provides specifications for insulation of industrial equipment, including a rectangular shape made of silicone coated steel with an operating temperature of 230°C, ambient temperature of 27°C, and cellular glass foam insulation that must not exceed 55°C. Calculations determine the required insulation thickness is 41.3mm for flat surfaces and 28.2mm for cylindrical surfaces of 100mm diameter oriented vertically.

Uploaded by

zamijaka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 13

Basis Data

Shape = Rectangular
Material = Silicone Coated Fabric Carbon Steel
Operating temperature (TH) = 230
o
C
Ambient temperature (TA) = 27
o
C
Insulation = Cellular Glass Foam
Maximum insulation surface temperature (TS) = 55
o
C
Calculation
DTI = 175
o
C Temperature difference between operating temperature and insulation surface temperature
DTF = 28
o
C Temperature difference between insulation surface temperature and ambient temperature
TM = 142.5
o
C Average temperature of the shape
Q = 300 W/m
2
Heat losses Refer to fig 6.15a GPSA Sect 6
RI = 0.55 Required thermal resistance of insulation Refer to fig 6.15b GPSA Sect 7
For insulation material : Cellular Glass Foam ASTM C-552-79 Class 1
A = 0.3488 Refer to fig 6.14 GPSA Sect 6
B = 5.04E-04 Refer to fig 6.14 GPSA Sect 6
C = 1.14E-07 Refer to fig 6.14 GPSA Sect 6
D = 7.17E-10 Refer to fig 6.14 GPSA Sect 6
k = 7.51E-02
XF = 0.04 m
= 41.3 mm Required insulation thickness for flat surface
Shape = Cylinder
Size = 100 mm OD
Orientation = Vertical
XC = 30 mm Refer to fig 6.15c GPSA Sect 6
OD - including insulation - = 160 mm
Q/L = 150.72 W/linear m
Orientation = Horizontal
Orientation Factor = 1.35 Refer to GPSA Sect 6
Corrected DTF = 37.8
o
C Refer to fig 6.15a GPSA Sect 6
RI = 0.375 Required thermal resistance of insulation Refer to fig 6.15b GPSA Sect 7
XF = 0.03 m
28.2 mm
GPSA Sect 6