0% found this document useful (0 votes)
89 views

C 6102

308L-16 STICK (SMAW) electrode welding positions Typical Applications All, except vertical down Type 302, 304 and 308 stainless steels A743 and A744 Type CF-8 cast material designed with low carbon levels to help eliminate carbide precipitation in high temperature service Conformances AWS A5 / A5.4M: 2006 ASME SFA-A5.4: ABS: CWB / CSA W48-06: MIL-E-22200

Uploaded by

Mingo Eva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views

C 6102

308L-16 STICK (SMAW) electrode welding positions Typical Applications All, except vertical down Type 302, 304 and 308 stainless steels A743 and A744 Type CF-8 cast material designed with low carbon levels to help eliminate carbide precipitation in high temperature service Conformances AWS A5 / A5.4M: 2006 ASME SFA-A5.4: ABS: CWB / CSA W48-06: MIL-E-22200

Uploaded by

Mingo Eva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

WE L D I N G C O N S U M A B L E S C A T A L O G 195

Excalibur

308L-16
STICK (SMAW) ELECTRODE
Welding Positions
Typical Applications
All, except vertical down
Type 302, 304 and 308 stainless steels
A743 and A744 Type CF-8 cast material
Flux coating provides smooth arc transfer in
all welding positions, except vertical down
Versatile electrode designed to weld several
types of austenitic steels
Q2 Lot

- Certificate showing actual deposit


composition and calculated ferrite number
(FN) available online
Designed with low carbon levels to help
eliminate carbide precipitation in high
temperature service
Conformances
AWS E308L-16 Stainless
Key Features
AWS A5.4/A5.4M: 2006
ASME SFA-A5.4:
ABS:
CWB/CSA W48-06:
MIL-E-22200/2:
E308L-16
E308L-16
E308L-16
E308L-16
MIL-308L-16
DIAMETERS / PACKAGING
Diameter Length 8 lb (3.6 kg)
Easy Open Can
10 lb (4.5 kg)
Easy Open Can in (mm) in (mm)
3/32
1/8
5/32
3/16
(2.4)
(3.2)
(4.0)
(4.8)
12 (300)
14 (350)
14 (350)
14 (350)
ED033079
ED033080
ED033081
ED033082
MECHANICAL PROPERTIES
(1)
As Required per AWS A5.4/A5.4M: 2006
Yield Strength
(2)
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Ferrite
Number
Requirements - AWS E308L-16 Not Specied 520 (75) min. 35 min. Not Specied
Typical Performance
(3)
- As-Welded 370-420 (54-61) 540-595 (78-86) 50-55 8-9
TYPICAL OPERATING PROCEDURES
Current (Amps)
Polarity
(5)
3/32 in (2.4 mm) 1/8 in (3.2 mm) 5/32 in (4.0 mm) 3/16 in (4.8 mm)
DC+ 40-70 60-100 90-140 120-185
AC 40-70 60-100 90-140 120-185
(1)
Typical all weld metal.
(2)
Measured with 0.2% offset.
(3)
See test results disclaimer below.
(4)
AWS Requirement for E308-16 is 0.08% max. carbon.
(5)
Preferred polarity is listed first.
DEPOSIT COMPOSITION
(1)
As Required per AWS A5.4/A5.4M: 2006
%C
(4)
%Cr %Ni %Mo %Mn
Requirements - AWS E308L-16 0.04-0.08
(4)
18.0-21.0 9.0-11.0 0.75 max. 0.5-2.5
Typical Performance
(3)
0.02-0.03 19.5-19.8 9.7-10.3 0.04-0.13 0.6-0.9
%Si %P %S %Cu
Requirements - AWS E308L-16 1.00 max. 0.04 max. 0.03 max. 0.75 max.
Typical Performance
(3)
0.29-0.36 0.03 0.02 0.10
IMPORTANT: SPECIAL VENTILATION AND/OR EXHAUST REQUIRED
Fumes from the normal use of some welding products can contain significant quantities of components - such as chromium and manganese - which can lower the 5.0 mg/m
3
maximum exposure guideline for general welding fume.
BEFORE USE, READ AND UNDERSTAND THE MATERIAL SAFETY DATA SHEET (MSDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER.
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Avenue Cleveland, OH 44117-1199 U.S.A.
Phone: +1.216.481.8100 www.lincolnelectric.com
Lincoln Global, Inc. All Rights Reserved.
Issue Date 01/12
CUSTOMER ASSI STANCE POLI CY
The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our
customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond
to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees,
however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not
warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter
any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty
of ftness for any customers particular purpose is specifcally disclaimed.
Lincoln Electric is a responsive manufacturer, but the selection and use of specifc products sold by Lincoln Electric is solely within the control of, and remains the sole
responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service
requirements.
Subject to Change This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.
TEST RESULTS
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to
prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors,
including, but not limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confrm by qualifcation
testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.
Material Safety Data Sheets (MSDS) and Certifcates of Conformance are available on our website at www.lincolnelectric.com

You might also like