Horizontal 2 Phase Separator Sizing

The document provides design basis parameters for a gas-liquid separator including gas and liquid flow rates, operating pressures and temperatures, densities, and mist eliminator specifications. It then shows calculations for actual gas and liquid rates based on these parameters and simulations, required gas and liquid velocities, and holdup and surge volumes needed. A trial and error selection process is shown to determine the optimal separator length that meets minimum criteria for length to diameter ratio, area ratios, and holdup times.

Uploaded by

Jermaine Heath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
745 views

Horizontal 2 Phase Separator Sizing

The document provides design basis parameters for a gas-liquid separator including gas and liquid flow rates, operating pressures and temperatures, densities, and mist eliminator specifications. It then shows calculations for actual gas and liquid rates based on these parameters and simulations, required gas and liquid velocities, and holdup and surge volumes needed. A trial and error selection process is shown to determine the optimal separator length that meets minimum criteria for length to diameter ratio, area ratios, and holdup times.

Uploaded by

Jermaine Heath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 10

: :

: :
: :
DESIGN BASIS
BASED ON PROCESS FLOW DIAGRAM
GAS RATE = 145600 lb/hr Refer to Hysis Simulation
GAS RATE FOR DESIGN = 160160 lb/hr 10% tolerance
LIQUID RATE = 46100 lb/hr Assume or refer to Hysis Simulation
LIQUID RATE FOR DESIGN = 50710 lb/hr 10% tolerance
AQUEOUS RATE = 0 lb/hr Assume or refer to Hysis Simulation
AQUEOUS RATE FOR DESIGN = 0 lb/hr 10% tolerance
OPERATING PRESSURE = 989.5 psia
DESIGN PRESSURE 1072.5 psig
TEMPERATURE = 650 o
F
LIQUID DENSITY = 38.83 lb/ft
3 Refer to Hysis Simulation
AQUEOUS DENSITY = 62.43 lb/ft
3 Refer to Hysis Simulation
WITH MIST ELIMINATOR ( YES/NO ) = YES (Vane Pack Mist Elim.)
K FACTOR = 0.405 Fig 7-9 GPSA Sect 7 or
0.2714 Table 1. W.Y. Svrcek, W.D. Monnery
CALCULATION 0.271 Selected K Factor
GAS DENSITY = 4.010 lb/ft
3 Refer to Hysis Simulation
MIXED LIQUID DENSITY = 38.830 lb/ft
3
ACTUAL GAS RATE = 11.094 ft
3
/sec
ACTUAL GAS RATE REFER TO HYSIS FOR CHECK = 11.000 ft
3
/sec Refer to Hysis Simulation
LIQUID RATE = 21.766 ft
3
/min
LIQUID RATE REFER TO HYSIS FOR CHECK = 21.000 ft
3
/min Refer to Hysis Simulation
GAS VELOCITY = 0.800 ft/sec Equation 7-7 GPSA Sect 7
HOLD UP VOLUME VH = 217.658 ft
3 Refer to Svrcek & MonneryTable 2. Liquid holdup and surge times
SURGE VOLUME VS = 108.829 ft
3 Refer to Svrcek & MonneryTable 2. Liquid holdup and surge times
HOLD UP + SURGE VOLUME (V2) = 326.487 ft
3 Assume that total hold up + surge volume is 60% total volume
CORROSION ALLOWANCE = 3 mm
= 0.11811 inch
ALLOWABLE STRESS = 17500 psi
WELDED EFFICIENCY = 0.85
TRIALL & ERROR :
The table below should be hiden during printing
DT AT AL1 AV UV LMIN Remark LSELECTED AHOLD UP
HHOLD
UP
HSURG
E
ft ft
2
ft ft ft ft
2
ft ft ft ft
2
ft ft ft sec ft/sec ft ft ft ft
2
ft ft
1 5.18 5.00 21.03 0.833 0.80 0.83 0.16 0.10 2.19 2.00 1.04 2.00 0.39 0.36 7.50 28.80 25.88 28.80 2.50 1.48 3.70 Oke 28.80 7.56 0.36 0.39 2.01 0.33
2 5.58 4.00 24.40 0.833 0.82 0.83 0.15 0.09 2.28 2.00 1.12 2.00 0.36 0.32 7.87 22.92 22.30 22.92 2.50 1.41 3.53 Oke 22.92 9.50 0.39 0.41 2.30 0.44
3 4.87 6.00 18.62 0.833 0.79 0.83 0.17 0.11 2.12 2.00 0.97 2.00 0.41 0.39 7.20 35.11 29.22 35.11 2.50 1.54 3.85 Oke 35.11 6.20 0.33 0.37 1.79 0.25
4 7.02 2.00 38.73 0.917 0.88 0.92 0.13 0.08 2.97 2.00 1.40 2.00 0.28 0.23 9.09 12.24 14.05 14.05 2.50 1.22 3.05 Oke 14.05 15.49 0.40 0.42 2.96 1.15
5 6.14 3.00 29.56 0.917 0.84 0.92 0.15 0.09 2.76 2.00 1.23 2.00 0.33 0.28 8.36 17.72 18.41 18.41 2.50 1.33 3.32 Oke 18.41 11.82 0.40 0.42 2.58 0.63
HLA
NLA
LLA
(HHOLD
UP/DT)
134.5 mm
PROJECT
CLIENT
SERVICE
PETRONAS CARIGALI PAKISTAN
DEETHANIZER REFLUX DRUM
L = 6986 mm
HV =
Min 12.0 Inch
LLA
NLA
HLA
Surge =
Hold Up =
Min 12.0 Inch
254.0 mm
HV
(HV/DT) (AV/AT)
L
HLL =
609.6 mm
701.2 mm
TYPE
CASE
HORIZONTAL, 2 PHASE
DESIGN FLOW RATE
TAG NO
PT.ISTANA KARANG LAUT
HORIZONTAL SEPARATOR
ID = 1699 mm
Trial
No
L/DT (AL1/AT) (HL1/DT)
HL1
(AHOLD UP/AT)
A
A
LL
A
H
A
S
Coulson Ricardson
Coulson Ricardson
Coulson Ricardson