Sample Welding Procedure Specification (WPS) : Joints (See 4.13.1)
Sample Welding Procedure Specification (WPS) : Joints (See 4.13.1)
1M:2009
Approved by _____________________________________
Approved by(Signature Required)
1
12 Mei 2014
WPS No. _____________________________________
Date ___________________________________________
0
WPS Revision No.______________________________
Rev. Date _______________________________________
Pre-Qualified
Supporting PQR Nos. ______________________________________________________________________________
SMAW
Manual
Welding Process(es) ____________________________
Type(s) _________________________________________
(Manual, Semiautomatic, Automatic, Robotic, Mechanized)
Joint Details
Other ___________________________________________
AWS Specification_________________________________
Other ___________________________________________
Electrode Flux (Class)______________________________
Flux Trade Name__________________________________
Other ___________________________________________
1G (Horizonal)
Position(s) of Groove____________________________
Position(s) of Fillet______________________________
Weld Progression ______________________________
267
AWS B2.1/B2.1M:2009
Root Shielding
Trailing
Environmental Shielding
Gas(es)
Composition
Flow Rate
Electrical Characteristics (see 4.13.8)
DCEP (Reverse)
Type/Polarity____________________________
Current
Pulsing: Yes
No
300 A
Current (Range) _______________________________
25 V
Voltage (Range) _______________________________
Wire Feed Speed (Range) _______________________
Tungsten Electrode Size/Type_____________________
Pulsing Parameters _____________________________
Transfer Mode _________________________________
Other ________________________________________
____________________________________________
____________________________________________
Welding Parameters
Filler Metal
Electrical
Layers
Process
Class
Diameter
Type and
Polarity
single
SMAW
A 5.1 E 6013
2.6 mm
DCRP
Current
Range
Voltage
Range
Travel
Speed
Range
300 A
25 V
8 mm/s
We, the undersigned, certify that the statements in this record are correct and the test welds were prepared, welded,
and tested in accordance with the requirements of AWS B2.1/B2.1M, ( __________), Specification for Welding Procedure
and Performance Qualification.
(year)
Manufacturer or Contractor __________________________________________________________________________
12 Mei 2014
Date __________________________
By_____________________________
____________________________
(Please Print)
(Signature Required)
268