This document provides product data and specifications for the Schneider Electric RM4TR32 three-phase network control relay. The relay monitors a three-phase power supply for overvoltage, undervoltage, and phase failure, with adjustable time delays from 0.1 to 10 seconds. It has two changeover output contacts to indicate detected faults. The document describes the relay's technical characteristics including measurement range, switching thresholds, accuracy, electrical ratings, mounting details, and environmental specifications.

Uploaded by

Taz Uddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
288 views

Zelio Control RM4TR32

This document provides product data and specifications for the Schneider Electric RM4TR32 three-phase network control relay. The relay monitors a three-phase power supply for overvoltage, undervoltage, and phase failure, with adjustable time delays from 0.1 to 10 seconds. It has two changeover output contacts to indicate detected faults. The document describes the relay's technical characteristics including measurement range, switching thresholds, accuracy, electrical ratings, mounting details, and environmental specifications.

Uploaded by

Taz Uddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Aug 7, 2014
1
Product data sheet
Characteristics
RM4TR32
three-phase network control relay RM4-T -
range 300..430 V
Main
Range of product Zelio Control
Product or component
type
Industrial measurement and control relays
Relay type Control relay
Product specific appli-
cation
For 3-phase supply
Relay name RM4-T
Relay monitored pa-
rameters
Overvoltage and undervoltage detection
Phase failure detection
Phase sequence
Time delay Adjustable 0.1...10 s
Measurement range 290...484 V
Contacts type and com-
position
2 C/O
Poles description 3P
Complementary
[Us] rated supply voltage 380...440 V 50/60 Hz
Control threshold undervoltage 300...430 V
Control threshold overvoltage 420...480 V
Output contacts 2 C/O
Setting accuracy of the switching threshold +/-3 %
Switching threshold drift <= 0.5 % within the measuring range
<= 0.06 % per degree centigrade depending permissible ambient air temperature
Setting accuracy of time delay 10 P
Time delay drift <= 0.5 % within the measuring range
<= 0.07 % per degree centigrade depending on the rated operational temperature
Hysteresis 5 % fixed of de-energisation threshold
Delay at power up < 650 ms
Measuring cycle <= 80 ms
Marking CE : EMC 89/336/EEC
CE : LVD 73/23/EEC
Overvoltage category III conforming to IEC 60664-1
[Ui] rated insulation voltage 500 V conforming to IEC
Supply frequency 50/60 Hz +/- 5 %
Operating position Any position without
Connections - terminals Screw terminals 2 x 2.5 mm, flexible cable without cable end
Screw terminals 2 x 1.5 mm, flexible cable with cable end
Tightening torque 0.6...1.1 N.m
Mechanical durability <= 30000000 cycles
[Ith] conventional free air thermal current 8 A
[Ie] rated operational current 0.3 A at 70 C 115 V DC-13 conforming to VDE 0660
0.3 A at 70 C 115 V DC-13 conforming to IEC 60947-5-1/1991
0.1 A at 70 C 250 V DC-13 conforming to VDE 0660
0.1 A at 70 C 250 V DC-13 conforming to IEC 60947-5-1/1991
3 A at 70 C 250 V AC-15 conforming to VDE 0660
3 A at 70 C 250 V AC-15 conforming to IEC 60947-5-1/1991
3 A at 70 C 24 V AC-15 conforming to VDE 0660
3 A at 70 C 24 V AC-15 conforming to IEC 60947-5-1/1991
3 A at 70 C 115 V AC-15 conforming to VDE 0660
3 A at 70 C 115 V AC-15 conforming to IEC 60947-5-1/1991
2 A at 70 C 24 V DC-13 conforming to VDE 0660
2 A at 70 C 24 V DC-13 conforming to IEC 60947-5-1/1991
2
Switching capacity in mA 10 mA at 12 V
Switching voltage 250 V AC
<= 440 V AC
Contacts material 90/10 silver nickel contacts
Number of cables 2
Height 78 mm
Width 22.5 mm
Depth 80 mm
Terminals description ISO n1 (15-16-18)OC
(25-26-28)OC
(L1-L2-L3)CO
Output relay state Tripped, fault present
9 mm pitches 2.5
Product weight 0.11 kg
Environment
Standards EN/IEC 60255-6
Product certifications CSA
GL
UL
Ambient air temperature for storage -40...85 C
Ambient air temperature for operation -20...65 C
Relative humidity 15...85 % 3K3 conforming to IEC 60721-3-3
Vibration resistance 0.35 ms (f = 10...55 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection IP50 (casing) conforming to IEC 60529
IP20 (terminals) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2.5 kV
Non-dissipating shock wave 4.8 kV
Resistance to electrostatic discharge 8 kV air conforming to IEC 61000-4-2 level 3
6 kV contact conforming to IEC 61000-4-2 level 3
Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3
Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3
Protection against electric shocks 2 kV conforming to IEC 61000-4-5 level 3
Disturbance radiated/conducted CISPR 11 group 1 - class A
CISPR 22 - class A
3
Product data sheet
Dimensions Drawings
RM4TR32
3-phase Supply Control Relays
Dimensions
4
Product data sheet
Mounting and Clearance
RM4TR32
3-phase Supply Control Relays
Rail mounting
Screw fixing
5
Product data sheet
Connections and Schema
RM4TR32
3-Phase Supply Control Relays
Wiring Diagram
L1,
L2,
L3
Supply to be monitored
15-18,
15-16
1st C/O contact of the output relay
25-28,
25-26
2nd C/O contact of the output relay
Application Scheme
Example
(1) Fault
6
Product data sheet
Performance Curves
RM4TR32
Electrical Durability and Load Limit Curves
AC Load
Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles
X Current broken in A
Y Millions of operating cycles
Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1)
X Power factor on breaking (cos )
Y Reduction factor K
Example: An LC1-F185 contactor supplied with 115V/50Hz for a consumption of 55VA or a current consumption equal to 0.5A and cos =
0.3.
For 0.5A, curve 1 indicates a durability of approximately 1.5 million operating cycles.
As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.
For cos = 0.3: k = 0.6
The electrical durability therefore becomes:
1.5x10
6
operating cycles x 0.6 = 900000 operating cycles
DC Load
Load limit curve
X Current in A
Y Voltage in V
1 L/R = 20 ms
2 L/R with load protection diode
3 Resistive load
7
Product data sheet
Technical Description
RM4TR32
Function Diagram
Overvoltage and Undervoltage Detection
Functions "Fault detection delayed" or "Fault detection extended (by switch selector)
t Time delay (adjustable from 0.1s to 10s with a selector switch)
U 3-phase supply voltage monitored (between terminals L1, L2 and L3)
S Overvoltage or undervoltage setting
15/18,
15/16;
25/28,
25/26
Output relays connections (refer to Connections and Schema)
Relay status: black color = energized.
NOTE: In order to be detected, the duration of the overvoltage or undervoltage must be greater than the measuring cycle time (80ms).