Condenser Calculation

This document provides specifications and calculations for designing a surface condenser according to HEI standards. It includes input parameters like steam flow rate, pressures, temperatures, material specifications. It then calculates the heat load, cooling water requirements, LMTD, heat transfer coefficient, required surface area, number of tubes, tube length and diameter required for the condenser. It also calculates the expected pressure drop across the condenser.
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
6K views

Condenser Calculation

This document provides specifications and calculations for designing a surface condenser according to HEI standards. It includes input parameters like steam flow rate, pressures, temperatures, material specifications. It then calculates the heat load, cooling water requirements, LMTD, heat transfer coefficient, required surface area, number of tubes, tube length and diameter required for the condenser. It also calculates the expected pressure drop across the condenser.
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

1 Mass flow rate = 1319510

2 Steam inlet pressure = 0.102


3 Steam inlet temperature = 45.836
4 Given enthalpy = 568.33
5 Saturated enthalpy of the liquid = 45.816
6 Saturated enthalpy of the vapour = 617.21
7 Cooling water velocity = 2.15
8 Dryness fraction = 0.91
9 Cooling water inlet temperature = 33
10 Cooling water outlet temperature = 43
11 Temperature difference = 10
13 Allowable pressure drop on tube side = 0.5
14 Cleanliness factor = 0.9
15 Tube MOC = SS 304
Heat load calculation ( Q )
Heat load on the condenser = 749917118
Actual heat load on the condenser = 753960096.9
Drains connection heat load = 12500
Total heat load = 753972596.9
Cooling water flow rate = 75397260
Density of cooling water at mean temp. = 1000
Total cooling water requirement Q
W
= 75397.26
Tube OD = 19.05
Tube thickness BWG = 0.89
Tube ID = 17.27
Cross sectional area of the tube = 0.000234332
LMTD calculation
Temperature difference ( TR ) = 10
Initial temperature difference ( ITD ) = 13
Terminal temperature difference ( TTD ) = 2.836
Condenser Design Calculation (According to HEI standards)
Input Data:
Calculation:
LMTD = TR / ln (ITD/TTD) = 6.62
Corrected heat transfer co-efficient(U) calculation
Uncorrected heat transfer co-efficient(U1) = 706.4
= 3448.6448
Tube material factor(Fm) = 0.82
Cleanliness factor(Fc) = 0.9
Water correction factor(Fw) = 1.079
Corrected heat tranfer co-efficient(U)
( U = U1 X Fm X Fc X Fw ) = 2746.16
Requirement of surface area ( A )
Total area required for heat transfer = 41453.93
( Q = U X A X LMTD )
Total number of tubes required = 41570.30
( Q
W
= N X A X V )
Length of the tubes required = 16.6624
( A = Pi X d X N X L)
Diameter of the condenser required = 7474.9
D=Tube OD X sqrt(no of tubes / 0.27 )
Pressure drop across the condenser
P = Lt x (Rt x R2 x R1) + (Re1+Re2+Re3)
HEI for Surface Condenser- 9th edition with Addendum
kg/hr
kg/cma
C
kcal/kg
kcal/kg
kcal/kg
m/s 7.052 ft/s
C
C
C
kg/cm
kcal/hr 872402 KW
kcal/hr 877106 KW
kcal/hr 15 KW
kcal/hr 877120 KW
kg/hr
kg/m
m/hr
0.75 inch
0.035 inch
mm 0.680 inch
m
C
C
C Minimum 2.8C- As per HEI
Condenser Design Calculation (According to HEI standards)
C
Btu / hr ft F
kcal / hr m C
kcal/hr m C
m
Nos
m
mm
0.27