100% found this document useful (1 vote)
998 views

End Plate Connection

This document summarizes the design of an end plate connection using 4 bolts. It provides the loading conditions, member properties, bolt properties, and connection geometry. It then calculates the potential resistance capacities of the bolts in tension, including the column and end plate flange bending and web tension capacities. The minimum potential resistance values are reported for each bolt row.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
998 views

End Plate Connection

This document summarizes the design of an end plate connection using 4 bolts. It provides the loading conditions, member properties, bolt properties, and connection geometry. It then calculates the potential resistance capacities of the bolts in tension, including the column and end plate flange bending and web tension capacities. The minimum potential resistance values are reported for each bolt row.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 10

241495534.xls.

ms_office 8/17/2014 2:01 PM 1/10


END PLATE CONNECTION DESIGN Job Name :
Calcs by : Revision No. Filename :
End Plate Connection - Moment Connection Design -4 Bolts
c. Design Nominal Reactions
Compression F
x
= 0.00 KN ; Check Staad Output
Tension F
x
= 23.00 KN ; Check Staad Output
Shear Force F
y
= 20.00 KN ; Check Staad Output
Shear Force Fz = 2.00 KN ; Check Staad Output
Bending moment Mz = 20.00 K-m ; Check Staad Output
Bending moment My = 3.00 K-m ; Check Staad Output
Supporting Member :
Beam Properties
Beam Section : = UC 203X203
Depth of column or plate D = 203.2 mm
Width of column flange or plate Bp = 203.60 mm
Web thickness of column or stiffener tc = 7.20 mm
Flange thickness of column or plate tf = 11.00 mm
Root radius of column or weld to plate r = 10.20 mm
and stiffener
Supported Member
Column Section = UC 203X203
Depth of column or plate D = 203.2 mm
Width of column flange or plate Bp = 203.60 mm
Web thickness of column or stiffener tc = 7.20 mm
Flange thickness of column or plate tf = 11.00 mm
Root radius of column or weld to plate r = 10.20 mm
and stiffener
Dimensions of the End Plate :
Length of the End Plate = 300.00 mm
Width of the End Plate = 204.00 mm
Thickness Provided, tp = 20.00 mm
Connection Details
Assumed bolt configuration
Grade of Bolts (8.8 / HSFG) = HSFG Part - 1Bolts
No. of bolt rows nr = 2.00
No. of bolt columns nc = 2.00
Total no. of bolts n = 4.00
Diameter of Bolt d d = 24.00 mm
Diameter of Bolt hole Dh Dh = 26.00 mm
Gross Area of Bolt , Ag Ag = 452.16 mm2
Tensile Stress area of Bolt As As = 352.91 mm2
Pitch ( Spacing between rows ) P = 80 mm
Guage ( Spacing between columns ) g = 90 mm
Edge Distance ( Top ) etop = 40.00 mm
End Distance ( Bottom ) e2bottom = 40 mm
End Distance ( Side ) e' = 40.00 mm
Slip factor for untreated = 0.50
For clearance holes Ks = 1.00 T1
Least thick of plate t = 11.00 mm
a 1 = 136.10
Forces in Bolts
Tension per bolt due to Moment Mz T2
For Row 1 T1 = Mz*a1/(nc(a1+a2)
T1 = 62.80 KN a2= 56.10
For Row 2 T2 = Mz*a2/(nc(a1+a2)
T2 = 25.89 KN Assumed Rotation Point
STRUCTURAL CALCULATIONS
SAMALSADI
241495534.xls.ms_office 8/17/2014 2:01 PM 2/10
END PLATE CONNECTION DESIGN Job Name :
Calcs by : Revision No. Filename :
STRUCTURAL CALCULATIONS
SAMALSADI
Tension per bolt due to Moment My
For Column 1 T1 = My/(nr*g)
T 1 = 16.67 KN
g = 90.00
Tension per bolt due to Axial = Fx/n
tension Fx 5.75 KN Assumed Rotation Point
Maximum forces Transfer to Each Bolt
Maximum Tension in bolt row 1 = 85.22 KN
Maximum Tension in bolt row 2 = 48.30 KN
Check for Bolts :
Yield strength of bolt Yf = 882.00 N/mm2
Ult. Tensile strength of bolt Uf = 981.00 N/mm2
Shear stress of bolt Ps = 400.00 N/mm2
Tension stress of bolt Pt = 700.00 N/mm2
Bearing stress of bolt Pbb = 1,300.00 N/mm2
Minimum proof stress P0 = 776.00 N/mm2
of bolt
Minimum shank tension P0 = 232.70 KN
in HSFG bolts
Capacity of one bolt
Shear capacity of bolt Ps = 141.16 KN
Bearing capacity of bolt Pb = 346.67 KN
Tension capacity of bolt Pt' = 209.43 KN 0.9*P0
Slip resistance of one bolt PsL = 0.9 * Ks * * P0
= 104.72 KN
Design strength of steel py = 345.00 N/mm2
Bearing strength of steel pb = 825.00 N/mm2
Design strength of weld pw = 220.00 N/mm2
Connection Geometry
Column Side
m1 = g/2 - tc/2 - 0.8rc m2 = (dc-P)/2 40.40 mm
= 33.24 mm
e = B/2-g/2
= 56.80 mm
For n smallest of n = 41.55 mm
e for the column flange = 56.80 mm
e for the end plate = 56.80 mm
1.25 m for column flange= 41.55 mm
Beam
m = g/2 - tc/2 - 0.8rc
= 36.60 mm Leg length of fillet weld to beam web, Sww =
e = B/2-g/2 6.00
= 56.80 mm
For n smallest of n = 45.75 mm
e for the column flange = 56.80 mm
e for the end plate = 56.80 mm
241495534.xls.ms_office 8/17/2014 2:01 PM 3/10
END PLATE CONNECTION DESIGN Job Name :
Calcs by : Revision No. Filename :
STRUCTURAL CALCULATIONS
SAMALSADI
1.25 m for column flange= 45.75 mm
Potential Resistance of Bolts in Tension Zone
Bolt Row 1 & 3
Bolt Row 1 & 3 alone
Column Flange Bending
Calculate effective length of T-stub as per Table2.2 of SCI
For bolt row below the flange of a flush end plate
Leff = Min of [ Max{ii,iii}, i ]
Ref. Table 2.2 of moment connection by BCSA
Leff for i = 2 m 208.75 mm
Leff for ii = 4m+1.25e 203.96 mm
Leff iii = m1 1 = m1/(m1+e) 1 = 0.39
2 = m2/(m1+e) 2 = 0.45
where from Fig 2.16 = 6.00
Leff iii = 199.44 mm
Ledd = min of ( max(i,iii),ii) 203.96 mm
Plastic moment capacity of the Mp = Leff x tf x py/4
equivalent T-stub = 2.13 KN.m
Potential resistance is the minimum of the following
Mode 1 Complete flange yielding Pr = 4 Mp / m 256.15 KN
Mode 2 Bolt failure with flange Pr = (2 Mp + n( Pt'))/(m+n)
yielding = 289.62 KN
Mode 3 Bolt failure Pr = Pt'
418.86 KN
Potential resistance for column flange bending Pr = 256.15 KN
Column Web Tension
As row 1 & 3 is near the flange, web tension can be discounted
End Plate Bending
Calculate effective length of T-stub as per Table2.5 of SCI
For bolt row below the flange of a flush end plate
Leff = Min of [ Max{ii,iii}, i ]
Ref. Table 2.4 of moment connection by BCSA
Leff for i = 2 m 229.85 mm
Leff for ii = 4 m + 1.25 e 217.40 mm
Leff iii = m1 1 = m1/(m1+e) 1 = 0.39
2 = m2/(m1+e) 2 = 0.43
where from Fig 2.16 = 6.00
Leff iii = 219.60 mm
Plastic moment capacity of the Mp = Leff x tf x py/4
equivalent T-stub = 7.58 KN.m
Potential resistance is the minimum of the following
241495534.xls.ms_office 8/17/2014 2:01 PM 4/10
END PLATE CONNECTION DESIGN Job Name :
Calcs by : Revision No. Filename :
STRUCTURAL CALCULATIONS
SAMALSADI
Mode 1 Complete flange yielding Pr = 4 Mp / m 828.00 KN
Mode 2 Bolt failure with flange Pr = (2 Mp + n( Pt'))/(m+n)
yielding = 416.70 KN
Mode 3 Bolt failure Pr = Pt'
418.86 KN
Potential resistance for column flange bending Pr = 416.70 KN
Beam Web Tension
As row 1 & 3 is near the flange, web tension can be discounted
Bolt Row 2
Row 2 and 1 as group
Column Flange Bending
Calculate effective length of T-stub as per Table2.6 of SCI
Leff = { Max of [ ii/2,(iii-ii/2)] }x2 + p 283.96 mm
Plastic moment capacity of the Mp = Leff x tf x py/4
equivalent T-stub = 2.96 KN.m
Potential resistance is the minimum of the following
Mode 1 Complete flange yielding Pr = 4 Mp / m 356.62 KN
Mode 2 Bolt failure with flange Pr = (2 Mp + n( Pt'))/(m+n)
yielding = 544.65 KN
Mode 3 Bolt failure Pr = Pt'
837.72 KN
Potential resistance for column flange bending Pr = 356.62 KN
Column Web Tension
Web tension can be discounted due to effective tensile length of web assuming a max. spread at
60deg from bolts to the centre of web is crossing the flange.
End Plate Bending
Calculate effective length of T-stub as per Table2.5 of SCI
Leff = { Max of [ ii/2,(iii-ii/2)] }x2 + p 301.80 mm
Plastic moment capacity of the Mp = Leff x tp x py/4
equivalent T-stub = 10.41 KN.m
Potential resistance is the minimum of the following
Mode 1 Complete flange yielding Pr = 4 Mp / m 1,137.93 KN
Mode 2 Bolt failure with flange Pr = (2 Mp + n( Pt'))/(m+n)
yielding = 718.27 KN
241495534.xls.ms_office 8/17/2014 2:01 PM 5/10
END PLATE CONNECTION DESIGN Job Name :
Calcs by : Revision No. Filename :
STRUCTURAL CALCULATIONS
SAMALSADI
Mode 3 Bolt failure Pr = Pt'
837.72 KN
Potential resistance for column flange bending Pr = 718.27 KN
Beam Web Tension
Web tension can be discounted due to effective tensile length of web assuming a max. spread at
60deg from bolts to the centre of web is crossing the flange
Potential Resistance of Bolts in Tension Zone
WORK SHEET: TENSION ZONE
Step 1 Column Side
Beam
Side
Row
Flange
Bending
Web Tension
Flange
Bending
Web
Tension
Potential
Resistance
1.00 Resistance of Row 1 256.15
256.15 N.A 416.70 N.A
2.00
Resistance of
Row 2 only
100.47
256.15 N.A 416.70 N.A
Resistance of
Row 2+1 as
group
356.62 N.A 718.27 N.A
100.47 301.57
Pr1 = Capacity of row 1 alone
Pr2 = Min. of { Capacity of row 2 alone,
( Capacity of row 2+1 ) - Pr1 }
241495534.xls.ms_office 8/17/2014 2:01 PM 6/10
; Check Staad Output
; Check Staad Output
; Check Staad Output
; Check Staad Output
; Check Staad Output
; Check Staad Output
STRUCTURAL CALCULATIONS
241495534.xls.ms_office 8/17/2014 2:01 PM 7/10
STRUCTURAL CALCULATIONS
mm
241495534.xls.ms_office 8/17/2014 2:01 PM 8/10
STRUCTURAL CALCULATIONS
241495534.xls.ms_office 8/17/2014 2:01 PM 9/10
STRUCTURAL CALCULATIONS
241495534.xls.ms_office 8/17/2014 2:01 PM 10/10
STRUCTURAL CALCULATIONS