Design of Compined Footing

This document contains the design of a combined footing to support two columns. It provides the input data for the column dimensions and loads. It then describes the design process which includes calculating the required base area, locating the resultant force, evaluating soil pressure, checking punching shear capacity, and designing the flexural and shrinkage reinforcement. Reinforcement details are provided, along with design checks showing the footing is adequate to support the column loads.

Uploaded by

Dodeptrai Bk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Design of Compined Footing

This document contains the design of a combined footing to support two columns. It provides the input data for the column dimensions and loads. It then describes the design process which includes calculating the required base area, locating the resultant force, evaluating soil pressure, checking punching shear capacity, and designing the flexural and shrinkage reinforcement. Reinforcement details are provided, along with design checks showing the footing is adequate to support the column loads.

Uploaded by

Dodeptrai Bk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2445

Design of Compined Footing

.
:
24
:
:
:
0598195411 :

input data

input data
For Column (A)

For Column (B)


short side
40
50
30

Dimensions
DL
LL

X
ton
ton

long side
40

cm

Dimensions
DL
LL

short side
40
75
45

X
ton
ton

long side
40

cm

General information
Column (A)
50ton
30ton

fc'
250
kg/cm2
fy
4200
kg/cm2
qall net
15
t/m2
center-to-center space between columns
Diameter of T op reinforcement
20
Diameter of Bottom reinforcement
16
Footing depth
0.8
m

6
mm
mm

Column (B)
75ton
45ton

0.8

output data

Ag

1.4

6
P( A )
80ton

Establish the required base area of the footing :


13.33

P( R )
200ton

m2

locate the resultant of the column forces :


X
3.8
Length of footing ( L )
Width of footing ( B )

m
7.6
1.8

m
m

3.8m

Evaluate the net factored soil pressure :


P A (u)
108
P B (u)
162
q (u)
20.25
Effective depth ( d )

ton
ton
t/m2
715

mm

Check footing thickness for punching shear :


Column (A)
Vu
bo
Vc

91
2630
235

ton
mm
ton

Check Vc > Vu

OK

137
4460
398

ton
mm
ton

Check Vc > Vu

OK

Column (B)
Vu
bo
Vc

Draw S.F.D and B.M.D for footing :


108ton

162ton

35.53

M +v e (max)
M -v e (max)
V (max)

ton
112.3t

142.6
34.8
112.3

t.m
t.m
t

0.4

1.4m

142.6t.m

34.8t.m

Compute the areas of flexural reinforcement :


a- Top longitudinal reinforcement:

As (req)
# 0f bars

0.0044
55.16
18

cm2

20

mm

16

mm

b- Bottom longitudinal reinforce:

As (req)
# 0f bars

0.0010
22.58
11

cm2

c- Short Direction :
Under Column (A)
Effective depth d
MA, u
21.64

0.0016
As (min)
10.81
# 0f bars
5

701
t.m
cm2

mm

16

mm

16

mm

Under Column (B)


MA, u

As (min)
# 0f bars

28.87
0.0011
15.85
8

t.m
cm2

Shrinkage Reinforcement in the short direction :


As (min)
# 0f bars

14.4
14

cm2
@

100 mm
6m

0.4

0.8m

8 16mm

8 16mm

Design By ENG.Mohammed AL-Saidy

P( B )
120ton

You might also like