The document provides design details for a commercial building project including structural design parameters, soil data, material specifications, loading information, and structural analysis and design outputs. Key aspects covered include the building being 14 stories with 3 basement levels, a flat slab structural system, soil bearing capacities, grade of concrete, dead and live load details, and wind and seismic load parameters. Design outputs including column sizes, beam designs, and slab designs are referenced.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
456 views
Design Brief
The document provides design details for a commercial building project including structural design parameters, soil data, material specifications, loading information, and structural analysis and design outputs. Key aspects covered include the building being 14 stories with 3 basement levels, a flat slab structural system, soil bearing capacities, grade of concrete, dead and live load details, and wind and seismic load parameters. Design outputs including column sizes, beam designs, and slab designs are referenced.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8
DESIGN REPORT
1. PROJECT INFORMATION (ADMINISTRATIVE)
(a) Project Title SAL 2 - AURUM (b) Location Gurgaon (c1) Client Salcon Group (c2) Clients representative, Telephone No. & Email Id ----- (d1) Architect Morphogenesis (d2) Dealing Architect, Telephone No. & Email Id S.No Name PH. No 01 Vijay Dahiya +91 11 41828070 02 Abhijit +91 11 41828070 03 Neha Singh +91 11 41828070
(e) Any other ----- 2. PROJECT INFORMATION (ARCHITECTURAL)
(a) Number of Building/Buildings :- 01 (b) Nature of Building/Buildings :- Commecial (c) Number of Basement :- 3 (d) Number of Floors :- G+14 (e) Provision w.r.t. floors :- 0 (f) Any other provision :- 0 (g) Typical floor heights :- 4.15 (h) Arch. Drawings :- Aneex G
3. STRL SCHEME (TICK THE RELEVANT SCHEME)
BEAM-SLAB FLAT SLAB WITH DROPS FLAT SLAB WITHOUT DROPS (i.e) FLAT PLATE STEEL STR.+ CONC. SLAB STEEL STR.+ SHEETING ANY OTHER Yes (on all floors)
NOTE ON REASON FOR SELECTING STRL SYSTEM :- Costing of structural System
(a) Expansion joint (Reason for selection of expansion joint). :- NO (Floor plate dimension is not so large) (b) Log of grid & structural system. :- 9mX9m (c) Str. Drawings :- Aneex H
4. SOIL DATA
(a) NGL w.r.t. zero level. :- @0.00 (b) Foundation Level/Levels :- @-13.350mt (c) Pile Capacities :- Pile is not used (d) Specification for side slopes for excavations. :- No (e) Liquefaction potential of soil :- Zero
NET SBC FOR = ISOLATED FOOTING = T/m 2 @
= m BELOW NGL COMBINED FOOTING = T/m 2 @
= m BELOW NGL RAFT =26 T/m 2 @
=14.00mt m BELOW NGL
GROSS SBC FOR = ISOLATED FOOTING = T/m 2 @
= m BELOW NGL COMBINED FOOTING = T/m 2 @
= m BELOW NGL RAFT =40 T/m 2 @
=14.00mt m BELOW NGL
RETAINING WALL DESIGN PARAMETER
=30 0
c = =1.8t/m 2
MODULUS OF SUBGRADE REACTION FOR DESIGN OF RAFT =16,000 kn/m 3 /m 2
WATER TABLE LEVEL CONSIDERED IN DESIGN =24.00 m BELOW NGL
5. GRADE OF CONC. USED IN DIFFERENT STRUCTURAL COMPONENTS
For Basement floors Floor No./ Area Self Finish Plaster Services Fill Partition Wall Fire Tender 3 nos. of Bmts As/size s 2.4Kn/sqm 3.6kn/sqm 0.5kn/m 2 0.5kn/m 2 18 kn/sqm (for 1mt earth fill) As/arch. Drawings on(25-0810) 10kn/sqm
For Typical floors Floor No./ Area Self Finish Plaster Services Partition Wall Earth Fill Sunken 14 nos. of Flrs As/size s 2.0Kn/sqm
0.5kn/m 2 0.5kn/m 2 As/arch. Drawings on(25-0810) 450 mm earth fill at exposed terrace 300mm light weight fill fill at Toilets
Note:- Codal ref. for above Is 875 part 1
2. Loading parameter for walls:-
ii. External Wall
S. No. Type Thickness (mm) Density Weight 1 Wall 230 20kn/m 3 4.6kn/m 2 External Plaster 12 20kn/m 3 0.24kn/m 3 Internal Plaster 18 20kn/m 3 0.36kn/m 4 External Cladding 230 20kn/m 3 4.6kn/m Total Weight of Wall Opening % 40 Total Weight Considered in Design s.no1+0.6*s.no4
iii. Internal Wall
S. No. Type Thickness (mm) Density Weight 1 Wall 230 20kn/m 3 4.6kn/m 2 External Plaster 12 20kn/m 3 0.24kn/m 3 Internal Plaster 18 20kn/m 3 0.36kn/m Note:- in office area uniform 1kn/sqm load has been taken for future partition.
3. LIVE LOAD CHART
S. NO. AREA & LEVEL NATURE OF USAGE LIVE LOAD CODAL REF. 1. Basements and part ground parking 5 kn/sqm Is 875 part 2 2. Part ground and above floors office 4 kn/sqm Is 875 part 2
4. MACHINERY/EQUIPMENT LOAD
S. NO. AREA & LEVEL NATURE OF USAGE LOAD CODAL REF. 1. DG commercial 1. 1500 KVA - 15500 Kg. 2. 1010 KVA - 12000 Kg Is 875 part 1 2. transformer 1 kn/sqm on contributrary area Is 875 part 1 3. Lift machine 7.5 kn/sqm on contributrary area Is 875 part 1
(5) WATER TANK LOADS & LOCATION
(a) OVERHEAD WATER TANKS
a. CAPACITY = 2lac liter b. SIZE = c. LOCATION = Mumty
S.No. Total Floor area (sqm) No. of Roofs Total DL Total LL Total (Dl+LL) Per sqm load 01 --------- 17 929958
179161
1019538.5 ----------
6.0 WIND LOAD PARAMETERS
BASIC WIND SPEED 47m/s LIFE SPAN 1 CLASS C CATAGORY 3 TERRAIN 1 INT. COEFF. 0.5 EXT. COEFF. 0.8 Kindly Note :- If gust load or user designed wind values are being applied in the model the attach calculations
7.0 Earth Quake Load
Z = Zone Factor = 0.24 R = Response reduction factor = 5 I = Importance Factor = 1 H = Building Height from earth quake consideration 66.65
Time period calculation with infill/without infill
P = 0.075 H .75 (without infill)
= 1.716
Calculation for H, b, d. with plan/section.
Base shear Calculation
T = 2.566Sec. Z = 0.24 Sa/g = 0.792 I = 1 Ah = 0.019021 R = 5
Vb = 10114.32Kn
Note:- Check analysis base shear with manual base shear. by using formulae W*Ah Where W= Lumped weight of the str (calculated as per IS 1893 part 1 Cl. 7. Ah = {(Z*I)/(2*R)}*(Sa/g)
(a) Notation i. DL:- Dead Load ii. LL:- Live Load iii. EL:- Earth Quake Load EQx / EQy iv. WL:- Wind Load WLx / WLy x =@ 0 y =@ 90
(b) For Foundation
DL +K 1 (Reduced) Live Load
Where K 1 =Reduction factor which is as follows for columns as well.
No. of Floors % Reduction in total LL on all floors to be carried by the member under consideration 1 0 2 10 3 20 4 30 5 to 10 40 Over 10 50
S.No. Total Floor area (sqm) No. of Roofs Reduction % Total DL Total LL Fdn designLoad 01 17 50 929958
179161
1019538.5
(c) For Design in General
i. 1.5 (DL+LL) ii. 1.5 (DL EQx) iii. 1.5 (DL EQy) iv. 1.2 (DL EQx +K 2 LL) v. 1.2 (DL EQy +K 2 LL) vi. 0.9 DL 1.5 EQx vii. 0.9 DL 1.5 EQy Where K 2 is coefficient for reduction in Live Load For LL above 3 KN/m 2 K=0.5 Kindly note in above the EQX and EQY shall be replaced by eq with eccentricity loads (d) Load Combination for wind load in RCC Building for high rise buildings:- i. DL +LL WLx ii. DL +LL WLy iii. 1.5 (DL WLx) iv. 1.5 (DL WLy) v. 1.2 (DL +LL WLx) vi. 1.2 (DL +LL WLy) vii. 0.9 DL 1.5 WLx viii. 0.9 DL 1.5 WLy
(e) Addition load Combination for column design 1.5 (DL+K 1 LL) Where K 1 = Reduction coefficient factor which is mentioned in b.