NEATDEK 'T'bar open grille system provides a generous 74% contact area in flooring application, yet allow s w ater and other liquids to drain safely aw ay. TECHDEK is precision engineered in lightw eight alum inium w ith a m odular connection system requiring no w elding for assem bly.
NEATDEK 'T'bar open grille system provides a generous 74% contact area in flooring application, yet allow s w ater and other liquids to drain safely aw ay. TECHDEK is precision engineered in lightw eight alum inium w ith a m odular connection system requiring no w elding for assem bly.
C1/Sfb(23)Xh 04.13 2 As our founding product, Techdek set the benchm ark for N eaco's design excellence as one of the m ost versatile architectural grille system s around. W ith its patented construction and high perform ance qualities, Techdek is w idely recognised as a definitive architectural solution for a m ultitude of applications. The system is precision engineered in lightw eight alum inium w ith a m odular connection system requiring no w elding for assem bly. Precision in form , versatility in function W ith Techdek, versatility and perform ance com es in several form s: the range is available in a choice of distinct profiles, each individually designed to suit a variety of requirem ents and environm ents. A further choice of profiles is provided w ith Louvredek and Brise Soleil com bined sunscreen/w alkw ays. Innovation from the beginning FLAT BAR U tilising a proven design concept, our Flat Bar system provides a lightw eight, econom ical solution. Flat Bar is available in tw o standard thicknesses, but can be application engineered to m eet bespoke requirem ents. The system is an especially popular specification for screening applications. N-I BAR N -I Bars ribbed surface m akes it an ideal choice for environm ents in w hich non-slip qualities are im portant. Fitted in the sam e w ay as N eatdek and Flat Bar, N -I Bar boasts a high strength-to-w eight ratio and a particularly attractive appearance. NEATDEK The N eatdek Tbar open grille system provides a generous 74% contact area in flooring application, yet allow s w ater and other liquids to drain safely aw ay. N eatdek is available w ith a plain surface, cam bered slightly to assist drainage, or w ith a longitudinally ribbed finish (w ith or w ithout transverse serrations). N eatdek is a popular solution for decking applications and elevated floors such as balconies. Available w ith 8m m or 5m m gap 3 In the follow ing pages of this brochure w e w ill illustrate Techdek's versatility w ith exam ples of its use in a w ide range of projects, from screening and solar shading to flooring and ventilation grilles. Introducing the profiles 2 & 3 U nique features and benefits 4 Project Spotlights Screening/cladding 5 -8 Staging 9 Bridges 1 0 -1 6 Access w alkw ays 1 7 -1 9 Flooring 2 0 Ventilation grilles 2 1 Solar shading 2 2 -2 3 Term inology and technical specifications 2 4 -3 1 SERRATED FLAT BAR The Serrated Flat Bar provides sure footing in hazardous conditions w ith its anti-slip surface. It achieved the highest slip resistance in independent testing. SERRATED N-I BAR The Serrated N -I Bar provides sure footing in hazardous conditions w ith its anti-slip surface. It achieved the highest slip resistance in independent testing. LOUVREDEK Louvredeks dual purpose w alkw ay/sunscreen profile is m anufactured from panels com prising alternate louvre extrusions and alum inium rectangular flat bars. If a w alkw ay is not required, an alternative sunscreen profile is available w ith the louvre sections only. BRISE SOLEIL Brise Soleil uses curved alternate louvre extrusions to provide the sam e high perform ance as Louvredek, either as a com bined w alkw ay/sunscreen or solely as a sunscreen. l Aluminium extrusions providing a high quality and aesthetically pleasing finish, often difficult to achieve with other materials l Virtually maintenance free l Lightweight panels which are approximately 1/3 of the weight of steel panels of similar form l Panels in lengths of up to 7.3m long by nominal 1m wide l Retains high residual value and the aluminium is fully recyclable l A selection of load bar heights to accommodate a wide variety of spans and load conditions l A feature can be made of the panels by anodising or powder coating l Easy installation due to lightweight panels l Structural efficiency is achieved by passing the swage bar through the load bar without cutting into the top or bottom edge thus providing a panel of great rigidity and strength l Works in harmony with the environment A unique combination of features and benefits Working in harmony with the environment 4LIGHTWEIGHT One third the weight of steel, aluminium is light and easy to handle, so it saves on manpower 4ENVIRONMENTALLY FRIENDLY 100% recyclable with no downgrading of its properties and very little energy required for re-melting 4MAINTENANCE FREE Saves on manpower 4EASY ON THE EYE Aluminiums aesthetically pleasing properties can be further enhanced with coating or anodisation 4NON TOXIC Aluminium is an inert metal, completely impermeable 4NON COMBUSTIBLE Aluminium does not burn or aid combustion 4 CORROSIVE FREE Aluminium will with time generate a protective oxide film coating giving excellent resistance to corrosion Why specify Techdek? 4 PRO JEC T: Longley Park Sixth Form College, Sheffield ARC H ITEC T: Ellis Williams PRO FILE: Flat Bar APPLIC ATIO N : Screening Techdek w as selected for the aw ard-w inning 9m new build education facility, providing a security screen and solar shading for the ground floor. The system s aesthetic appeal and corrosion-resistant qualities w ere factors behind its specification. Project spotlight 5 Techdek w as extensively installed to provide screening for apartm ent balconies across 17 floors on each of three buildings at this 35m flagship residential developm ent overlooking Salford Q uays. Louvredek w as also selected to provide solar shading for the balconies. Project spotlight 6 PRO JEC T: NV Buildings, Salford Quays ARC H ITEC T: Broadway Malyan PRO FILE: Flat Bar, Louvredek APPLIC ATIO N : Screening, Solar Shading 7 Techdek is w inning plaudits for its perform ance as part of the Royal Shakespeare C om panys redevelopm ent of their C hapel Lane facilities adjacent to the m ain theatre. The product w as selected to provide vertical screening as part of the Leadbitter G roups reconfiguration of the existing U nion Building, reconstructing 600 square m etres of internal space w hilst retaining the existing faade and other features. Project spotlight Photograph courtesy David Stewart. 8 PRO JEC T: RSC Union Building C LIEN T: Leadbitter Group PRO FILE: Flat Bar APPLIC ATIO N : Screening Techdek toured the U K as part of the stage for the fam ous Feet of Flam es tour starring M ichael Flatley. C hosen to create tw o platform s because it is lightw eight yet load-bearing, Techdek is com m only used for staging because the grille allow s light to penetrate, creating an effect that can enhance the aesthetics of a show . Project spotlight 9 D esign com pany Im agination used Techdek on Fords stand to create a dram atic elevated stage, including a 65-m etre w alkw ay suspended above the exhibition hall floor. The system s load bearing qualities, ease of assem bly and lum inous appearance under stage lighting w ere all factors in choosing Techdek. PRO JEC T: Geneva Motor Show C LIEN T: Imagination PRO FILE: Neatdek APPLIC ATIO N :Staging PRO JEC T: Feet of Flames Tour C LIEN T: Brilliant Stages PRO FILE: N-I Bar APPLIC ATIO N : Staging Even when faced with the most challenging environments and technical specifications, there is never a bridge too far for Techdek. The system has become a prominent feature on a range of prestigious bridge designs, having been chosen as decking for pedestrian and cycle ways in a series of high profile developments in the UK and Ireland. In each case Techdeks strength and durability has met high performance requirements whilst its modular versatility has enabled the system to serve some of the most creative aspects seen in contemporary bridge architecture. Never a bridge too far... 10 Techdek is featured at W ilkinson Eyre Architects' G ateshead M illennium Bridge, a prestigious 17m schem e w hich w on the 2002 Stirling Prize and the Royal Fine Art C om m ission's Building of the Year 2002. Techdek w as used to create the bridge's alum inium cycle deck - a key feature that w as highlighted in the Stirling Prize judges' com m ents. 11 Project spotlight PRO JEC T: Gateshead Millennium Bridge ARC H ITEC T: Wilkinson Eyre Architects PRO FILE: Neatdek APPLIC ATIO N : Cycle Paths Techdek w as used to produce a special sensory effect in the M illennium G arden at N ottingham U niversity. The system w as installed just above the surface of a pool to create the feeling of w alking on w ater. Techdek's lightw eight construction requires m inim al support, providing a low er clearance so that the w ater level could be higher and closer. 12 Project spotlight PRO JEC T: Millennium Garden, Nottingham ARC H ITEC T: Quartet Design PRO FILE: Neatdek APPLIC ATIO N : Bridge Techdek w as extensively installed on the Living Bridge at the U niversity of Lim erick to form a curvaceous deck sw eeping across the River Shannon and its em bankm ents in six spans betw een strategically positioned support locations. D esigned by W ilkinson Eyre Architects, the Living Bridges deck w idth pulses along its length, offering w ider platform s for use as resting places or spaces for public art. Project spotlight 13 PRO JEC T: Living Bridge ARC H ITEC T: Wilkinson Eyre Architects PRO FILE: Neatdek APPLIC ATIO N : Bridge Project spotlight This unique opening footbridge links the M edia C ity developm ent for the BB C at Salford Q uays and The Im perial W ar M useum of the N orth. Techdek's grille path follow s a dram atic curved form w hich responds to the radial m asterplan of the site as an integral part of an orbital pedestrian route around the C anal basin. Behind a distinctive fanned m ast, the deck flares to form an am enable public space above the w ater. 14 Photographs courtesyJ onathan Smith PRO JEC T: Media City Footbridge ARC H ITEC T: Wilkinson Eyre Architects PRO FILE: Neatdek APPLIC ATIO N : Bridge Main photograph courtesyTanya Hart Project spotlight Techdek w as specified for the signature feature of the Tw in Sails Bridge in Poole H arbour. The bridges tw o hydraulically lifted sections are triangular sail shapes w hich cross as they rise and com e to rest in an overlapping com position, m irroring the shape of racing yachts passing through the bridge. Techdek grillage has been installed on both sail sections w hich form a sculptural piece w hen lifted into a vertical position. PRO JEC T: Twin Sails Bridge ARC H ITEC T: Wilkinson Eyre Architects PRO FILE: Neatdek APPLIC ATIO N : Bridge 15 PRO JEC T: Peace Bridge, Londonderry ARC H ITEC T: Wilkinson Eyre Architects PRO FILE: Neatdek APPLIC ATIO N : Cycle paths The Peace Bridge is one of the largest and m ost iconic projects to be supported under the European U nion's European Regional D evelopm ent Fund's Peace III Program m e. A Techdek cycle path is prom inently featured as part of a 235m -long cycle/footbridge across the River Foyle in D erry, Londonderry. This im pressive schem e has w on m ultiple aw ards, including W aterw ays Renaissance Aw ard for design and construction. 16 Photograph source: CAIN Project spotlight Techdek w as installed to provide cleaning access w alkw ays at Equinox H ouse, a prestigious com m ercial developm ent in G lasgow . The system w as also used as flooring for balconies. N eaco developed a flat bar balustrade system for this project very sim ilar to its Techbar range. Project spotlight 17 PRO JEC T: Equinox House, Glasgow ARC H ITEC T: GD Lodge Architects C LIEN T: Corus Building Systems PRO FILE: Neatdek APPLIC ATIO N : Access Walkway, Balcony Flooring Techdek w as installed as a m aintenance w alkw ay providing access to an atrium on the 100m , 500,000 square foot retail and leisure developm ent. The system w as also used to provide solar shading. Project spotlight PRO JEC T: Great Northern Development, Manchester ARC H ITEC T: Leslie J ones Architects PRO FILE: Serrated Bar APPLIC ATIO N : Access Walkway, Solar Shading 18 Project spotlight As approved suppliers of alum inium w alkw ay and handrail system s to Kalzip, N eaco provided a m ajor contribution to the St. Stephens developm ent in H ull, a 90 m illion schem e com prising 600,000 square feet of retail and leisure facilities. D esigned by H older M athias Architects, the undulating curved glass roof is a particularly distinctive design feature at St. Stephens and the Kalzip w alkw ay system (featuring Techdek) w as extensively installed on the roof structure for cleaning and m aintenance access. PRO JEC T: St. Stephens Retail Centre, Hull C LIEN T: Kalzip PRO FILE: N-I Bar APPLIC ATIO N : Roof Access Walkway 19 Project spotlight 20 Techdeks contem porary looks and durability in coastal sites m ade it an ideal specification at W hitburn C hurch of England School in South Tyneside. The new build developm ent includes tw o external coast- facing terraces w hich feature Techdek as w ell as a bespoke balustrade design adapted from N eacos Spectrum range. PRO JEC T: Whitburn Church of England School ARC H ITEC T: Silvester Ashton Partnership PRO FILE: Neatdek APPLIC ATIO N : Flooring 21 Project spotlight PRO JEC T: Brewery Wharf, Leeds ARC H ITEC T: DLA Architecture PRO FILE: N-I Bar APPLIC ATIO N : Ventilation Grille Techdek is featured at the high profile Brew ery W harf developm ent in Leeds city centre as part of a m ajor phase w hich includes 26,000 square feet of office space. The system has been installed as a ground-level ventilation grille w hich spans the front face of one of the office buildings. 22 Louvredek becam e an integral elem ent in C ity of York C ouncils extension of H axby H all, an elderly personshom e in York, helping to provide a bright alternative to m ore traditional design ideas. As the south facing side of the building, the extension required a high- perform ance sunshade system - a key dem and w hich is being m et by Louvredek. D eveloped in 2002, from Techdeks proven design, our Louvredek and Brise Soleil com bined w alkw ay/sunscreens achieve the optim um benefits of natural sunlight w hilst creating an energy-efficient environm ent in any building. Readily adaptable to your specific design requirem ents, the tw o system s can be installed anyw here required: underfoot, on an angle or overhead. They greatly reduce the net heat gain (com m only in the order of 20-40% ) of sunlight striking tinted or clear w indow s. Project spotlight PRO JEC T: Haxby Hall ARC H ITEC T: City of York Council PRO FILE: Louvredek APPLIC ATIO N : Solar Shading 23 Brise Soleil w as installed to provide visually attractive sunscreening to the exposed south facing elevation of the building as part of a m ajor redevelopm ent of Beverley Leisure C entre. N eacos Spectrum balustrade w as also installed inside the com plex. Project spotlight Louvredek has been selected as a key elem ent in the visually striking entrance at Sheffield C olleges N orth C entre cam pus developm ent. The lead consultant and architect, Jefferson Sheard, specified Louvredek for the 27m new build schem es highly visible entrance, w hich w as designed to create aesthetic im pact and increase the C ollege brand. PRO JEC T: Sheffield College C LIEN T: J efferson Sheard PRO FILE: Louvredek APPLIC ATIO N : Solar Shading/Access Walkways PRO JEC T: Beverley Leisure Centre C LIEN T: WS Atkins PRO FILE: Brise Soleil APPLIC ATIO N : Solar Shading Louvredek and Brise Soleil are m anufactured from panels consisting of alternate angled or curved extrusions and rectangular flat bars. The angled or curved bars are set at approxim ately 60m m centres and sw aged w ith 8m m square cross bars at 100m m centres. Either can be used for w alkw ays or solar shading. An angle of 62 degrees is m aintained even w hen the 25x3 flats are om itted. All m aterials used are alum inium alloy 6082 T6 or T4. Panels can be supplied in m ill finish or anodised AA15. 24 7 3 SW P 25/3/73 31 5 6 Louvredek SW S 25/3/56 1m 1 . 8 8 m 24 Brise Soleil Specification Brise Soleil Sunscreens (not to be walked upon) S S 3 /7 3 73m m deep curved bar Self w eight 11 kg/m 2 Typical clear spans for the SS/3/73 is 3.0m Based on: M ainland U K w ind speed of up to 25 m etres/second Site altitudes up to 150m Location up to 20m above ground floor level For locations outside these param eters contact our technical departm ent Load/Span Table (W alkw ay) M axim um clear span(m m ) Sunscreen w alkw ay spans quoted above can be increased by 100m m if the panel edge is supported by a deep bar (70x3 m in). Plain Bar 1/200 Span or 10m m Plain Bar 6.5m m Serrated 1/200 Span or 10m m Serrated 1/200 Span or 6.5m m LIG H T D U TY - Access lim ited to one person 3kN /m 2 U .D .L. 1900 1700 1800 1650 G EN ERAL D U TY - Regular tw o-w ay pedestrian traffic 5kN /m 2 U .D .L. 1600 1500 1500 1400 Pedestrian loading categories as described in BS 4592 part one: 1995 Brise Soleil 25/3/73 Brise Soleil W alkw ays S WP 2 5 /3 /7 3 73m m deep curved bar & 25m m x 3m m plain bar Self w eight 14.6 kg/m 2 S WS 2 5 /3 /7 3 73m m deep curved bar & 25m m x 3m m serrated bar Self w eight 14.3 kg/m 2 Louvredek Sunscreens (not to be walked upon) S S 3 /5 6 56m m deep angled bar Self w eight 8.9 kg/m 2 Typical clear spans for the SS/3/56 is 2.5m Based on: M ainland U K w ind speed of up to 25 m etres/second Site altitudes up to 150m Location up to 20m above ground floor level For locations outside these param eters contact our technical departm ent Sunscreen w alkw ay spans quoted above can be increased by 100m m if the panel edge is supported by a deep bar (50x3 m in). Plain Bar 1/200 Span or 10m m Plain Bar 6.5m m Serrated 1/200 Span or 10m m Serrated 1/200 Span or 6.5m m LIG H T D U TY - Access lim ited to one person 3kN /m 2 U .D .L. 1560 1500 1460 1400 G EN ERAL D U TY - Regular tw o-w ay pedestrian traffic 5kN /m 2 U .D .L. 1360 1350 1300 N /A Pedestrian loading categories as described in BS 4592 part one: 1995 Louvredek 25/3/56 Load/Span Table (W alkw ay) M axim um clear span(m m ) Louvredek W alkw ays S WP 2 5 /3 /5 6 56m m deep angled bar & 25m m x 3m m plain flat bar Self w eight 12.5 kg/m 2 S WS 2 5 /3 /5 6 56m m deep angled bar & 25m m x 3m m serrated flat bar Self w eight 12.2 kg/m 2 B Sw age Bar A Load-Bearing Bar K Serrated Bearer Bars L C learances M Extended Sw age Bars F Kicking Plate E Banding G C ut-outs W idth D H Pitch I End Plate J N osing 25 Panel Term inology Load-Bearing Bar The load-bearing m em ber spanning betw een supports. Sw age Bar A square bar that passes through the load-bearing bar that is sw age locked at right angles to the load-bearing bars providing lateral restraint. Length (direction of span) The overall dim ensions of a flooring panel m easured parallel to the load-bearing bars. W idth The overall dim ension of a panel m easured at right angles to the load-bearing bars. Banding A bar or section w elded to the edges of a flooring panel, generally flush w ith the top and bottom of the load-bearing bars. The banding can be straight or curved. Kicking Plate (Toe Plate) A flat bar around the edge of a flooring panel and projecting above the top of the load-bearing bars. C ut-outs The area rem oved to allow obstructions to pass through the panel. Pitch The distance from centre-to-centre of the load-bearing or sw age bars. End Plate A fixed plate on a stair or ladder tread for attaching to the stringer. Tread N osing A m em ber attached to the front of a stair tread or to a flooring panel. Serration C urved notches cut into the top surface of the load-bearing bars providing slip resistance across the w hole surface. C learances The gap betw een panels or adjoining structures. Extended Sw age Bars The sw age bars on one panel are extended so that the flooring appears to be continuous w hen view ed from top or bottom E F G H I J K L M A B C C Length C lear Span 3m m to 6m m End & Side of Panels 4m m to 12m m Betw een Panels 30.2m m 101.6m m 3m m to 6m m End & Side of Panels 4m m to 12m m Betw een Panels D 26 Panel range/ Surface options D E P T H S A V A IL A B L E 19 G 25 G 32 G 38 G 45 G 51 G 57 G 63 5m m H D E P T H S A V A IL A B L E 25 G 32 G 38 G 45 G 51 G 57 G 63 I D E P T H S A V A IL A B L E 25 G 32 G 38 G 45 G 51 G 57 G 63 G 89 G D E P T H S A V A IL A B L E 25 G 32 G 38 G 45 G 51 G 57 G 63 G 89 3m m F D E P T H S A V A IL A B L E 25 G 32 G 38 G 51 D E P T H S A V A IL A B L E 25 G 32 G 38 G 51 6m m D E D E P T H S A V A IL A B L E 19 G 25 G 38 G 51 5m m A D E P T H S A V A IL A B L E 25m m D EEP O N LY 8m m B N -I BAR D RIBBED N -I BAR E SERRATED N -I BAR O PEN G RILLE FLO O RIN G F 3m m PLAIN O PEN G RILLE FLO O RIN G G 3m m SERRATED O PEN G RILLE FLO O RIN G H 5m m PLAIN O PEN G RILLE FLO O RIN G I 5m m SERRATED O PEN G RILLE FLO O RIN G N EATD EK A 5m m G AP RIBBED N EATD EK D esigned for pedestrian com fort B 8m m G AP PLAIN N EATD EK C 8m m G AP RIBBED N EATD EK 25m m 22m m 8m m 22m m D E P T H S A V A IL A B L E 25 G 32 G 38 G 51 24m m 27m m 25m m C Panel Specification N EATD EK alum inium alloy decking panels incorporating the patented N EAC O sw age locking principle and providing a larger contact area than orthodox open grille flooring. 8m m G ap N EATD EK provides 74% contact area. 5m m G ap N EATD EK provides 84% contact area. The flooring enjoys the advantages of traditional open grille flooring by allow ing drainage for liquids and providing sunshading. N -I BAR alum inium alloy decking panels incorporating the sw age locking principle for a handsom e, lightw eight and structurally efficient open grille panel. N -I BAR achieves a high strength to w eight ratio and is available as standard w ith a ribbed or serrated surface. The 6.5m m bar has a 21% contact surface area w hich is larger than that offered by traditional flooring. All panels are available in lengths up to 7.3m. 27 Alum inium specification All load-bearing bars: Alum inium Alloy 6082 T6 All sw age bars: Alum inium Alloy 6082 T4 Tabulated panel w idths are m easured over the load-bearing bars. Tolerance is + 0m m , -3m m . The sw age bars extend through the load bearing bars as show n right. 3m m O PEN G RILLE 5m m O PEN G RILLE N -I BAR 4.8 1 2 2 3.2 O pen G rille Flooring N EATD EK N um ber of load bearing Bars 3m m Bars 5m m Bars N -I BAR 8m m G ap 5m m G ap 2 35 36 38 52.5 55.5 3 65 66 68 83 86 4 95 96 98 113 116 5 125 127 128 143 146 6 156 157 158 173 177 7 186 187 189 203.5 207 8 216 217 219 233.5 237 9 246 248 249 263.5 267.5 10 276 278 279 294 297.5 11 307 308 309 324 327.5 12 337 338 340 354 358 13 367 369 370 384.5 388 14 397 399 400 414.5 418 15 427 429 430 445 448 16 458 459 461 475 478.5 17 488 490 491 505.5 509 18 518 520 521 535.5 539 19 548 550 551 566 569 20 578 580 581 596 599.5 21 609 611 612 626.5 629.5 22 639 641 642 656.5 660 23 669 671 672 687 690 24 699 701 702 717 720.5 25 729 732 732 747.5 750.5 26 760 762 763 777.5 781 27 790 792 793 807.5 811 28 820 822 823 837.5 841 29 850 853 853 868 871.5 30 880 883 883 898 901.5 31 911 913 914 928 932 32 941 943 944 958.5 962 33 971 974 974 989 992 34 1001 1004 1004 P A N E L W ID T H S N E A T D E K N - I
B A R O P E N
G R I L L E
F L O O R I N G
P A N E L S The panels are available w ith a plain or serrated top surface. Serrated option The serrated panels provide a positive anti-slip surface across the entire surface to suit the m ost dem anding of situations. N eacos Serrated Flat Bar achieved the highest rating (R13) w hen tested for slip resistance in accordance w ith D IN 51 130. To achieve this rating the flooring surface m ust m aintain a non-slip condition at an angle in excess of 35. N EAC O open grille flooring uses traditional rectangular load-bearing bars secured into position by the N EAC O sw age locking process. The rectangular load bars are available in 3.2m m and 4.8m m w idths. Load/span table Maximum clear span (mm) BOLD The figures in bold show the maximum clear span for the category of loading whilst limiting the deflection to 1 /200 of the clear span or 10mm, whichever is the lesser. * Indicates that the clear span has been reduced further to allow for the effect of a 1kN concentrated load over an area 300mm x 300mm placed at the edge of the panel. Italics Where spans exceed 1300mm and pedestrian comfort is of paramount importance, the table provides details of clear spans which produce deflections of 6.5mm. Serration Weight The tabulated weight should be reduced by 0.7 Kg/m 2 PLAIN BAR SERRATED PLAIN BAR SERRATED PLAIN BAR SERRATED PANEL WEIGHT BAR TYPE Kg/M 2 HEIGHT OR 10mm 6.5mm OR 10mm 6.5mm OR 10mm 6.5mm OR 10mm 6.5mm OR 10mm 6.5mm OR 10mm 6.5mm 11.0 25 *1100 1080 940 12.0 32 *1470 1410 1320 1310 1150 13.0 38 1830 1650 1540 1480 1350 1340 19.6 51 2360 2120 2070 1860 1830 1680 8.4 19 *700 *700 700 13.0 25 1180 1140 1000 15.8 38 1850 1750 1640 1550 1430 1400 20.9 51 2460 2220 2180 1950 1960 1760 9.9 25 *1050 *700 1050 *700 920 *700 13.0 32 *1500 *1440 *1080 1340 1330 *1080 1170 940 14.0 38 1870 *1690 *1550 1380 1580 1500 1370 1350 1380 1360 1200 16.4 51 2300 2070 2120 1820 2030 1820 1820 1680 1780 1640 1600 1510 9.2 25 *840 *650 *840 *650 800 *650 11.0 32 *1180 *960 1140 *960 1000 870 13.0 38 *1560 1460 *1310 1360 1350 1220 1200 1070 14.7 45 *1890 1700 *1700 1560 1600 1520 1450 1410 1400 1370 1270 16.7 51 2020 1800 1980 1780 1820 1680 1680 1580 1600 1520 1470 1420 18.4 57 2220 2020 2190 1970 2040 1830 1910 1730 1800 1680 1670 1560 20.3 63 2500 2260 2390 2140 2200 1980 2100 1890 2000 1800 1870 1700 27.9 89 3200 2900 3100 2800 2840 2550 2740 2450 2550 2300 2450 2200 10.3 19 *675 *675 *675 13.0 25 *1030 *800 *1030 *800 910 760 15.7 32 *1450 1400 *1180 1305 1300 1140 1140 990 18.4 38 1860 1680 *1600 1500 1560 1500 1400 1370 1370 1360 1220 21.1 45 2120 1900 1970 1770 1830 1680 1640 1560 1590 1520 1450 1410 24.2 51 2340 2100 2200 1980 2060 1860 1920 1740 1820 1680 1680 1570 26.9 57 2560 2300 2420 2180 2260 2030 2130 1910 2040 1830 1900 1730 29.6 63 2780 2500 2640 2370 2440 2200 2320 2080 2200 1980 2100 1880 Pedestrian loading categories as described in BS 4592 part 0: 2006 LIGHT DUTY Access limited to one person 3kN/m2 U.D.L. GENERAL DUTY Regular two-way pedestrian traffic. 5kN/m2 U.D.L. HEAVY DUTY High density pedestrian traffic. 7.5kN/m2 U.D.L. 8mm GAP RIBBED NEATDEK 5mm GAP RIBBED NEATDEK N-I BAR 3mm FLAT BAR 5mm FLAT BAR PANEL TYPE 4.8 25.4 3.2 27 6.4 23.8 25.2 5 22.2 8 1 /200 SPAN 1 /200 SPAN 1 /200 SPAN 1 /200 SPAN 1 /200 SPAN 1 /200 SPAN 28 Stair treads/options Stairtread m axim um lengths have been calculated based on a sim ply supported condition w ith application of a 4.5kN concentrated load over an area 150m m square placed at the centre of the front edge of the tread. The m axim um deflection is lim ited to 1 /200 of the effective span or 6m m , w hichever is the lesser. * For tread lengths of 1500m m and greater, the tread has been designed to support the application of a 4.5kN load w hilst lim iting deflection to 6m m . 8m m G AP RIBBED N EATD EK G SU ITABLE FO R U SE O N FIRE ESC APE STAIRS RIBBED N -I BAR TREAD 5m m PLAIN BAR TREAD N E A T D E K N - I
B A R O P E N
G R I L L E
F L O O R I N G
P A N E L S 5m m SERRATED BAR TREAD M AX TREAD LEN G TH 8m m G ap 5m m G ap 32m m 1150 N /A 38m m 1200 1250 51m m 1450 1500 H EIG H T of Load Bearing Bar M AX TREAD LEN G TH Ribbed Serrated 32m m 1050 950 38m m 1200 1075 51m m 1400 1300 H EIG H T of Load Bearing Bar H EIG H T of Load Bearing Bar M AX TREAD LEN G TH Plain Serrated 32m m 1050 1000 38m m 1200 1100 51m m 1450 1400 TREAD W ID TH 9 270 10 300 11 330 12 360 13 390 14 420 15 450 N o. of Bearing Bars 32.38 51 100 80 75 55 H eight of Load Bearing Bar D im . x D im . y Tread W idth D im . A m m m m 250-350 120 351-460 212 TREAD W ID TH 8m m & 5m m G ap 9 274 10 304 11 334 12 364 13 394 14 424 15 454 N o. of Bearing Bars TREAD W ID TH 9 270 10 300 11 330 12 360 13 390 14 420 15 450 N o. of Bearing Bars T re a d W id th D IM A 14m m H ole X Y STAN D ARD EN D PLATE D ETAIL 52 6 3 5 2 2 5 N EW STAIR N O SIN G IN AC C O RD AN C E W ITH BS 8300 : 2009. C O LO U R AN O D ISED N O SIN G O PTIO N AVAILABLE. 29 30 Technical specification for N eaco Alum inium Roof W alkw ay System The roof access w alkw ay and handrail has been designed as a lightw eight roof access system for general cleaning and m aintenance purposes. The system is designed to B.S. 6399: part 1: 1996. Loadings for buildings Part 1 C ode of Practice for D ead and Im posed Loads under the follow ing headings. Roof access w alkw ays AC C ESS W ALKW AY M inim um im posed loads H AN D RAIL SYSTEM - TABLE 4 M inim um horizontal im posed loads for parapets, barriers and balustrades etc. RO O F W ALKW AY FEATU RES AN D BEN EFITS O FFERS Alum inium extrusions providing a high quality and aesthetically pleasing finish, often difficult to achieve w ith other m aterials Lightw eight panels w hich are approxim ately 1 3 of the w eight of steel panels of sim ilar form The benefits of a m odular system Virtually m aintenance free - no painting required Panels in lengths for easy handling, typically 1800m m to 2400m m by nom inal w idth 600m m . The w alkw ay retains a high residual value and the alum inium is fully recyclable H andrail to one or both sides of the w alkw ay 150m m kicking plate available as an optional extra Free draining serrated non-slip surface The ability to be placed level on slopes up to 10 PRO VID ES FO R A sim ple, quick installation Easy cutting of w alkw ay panels on site (W here feasible) clam ping to the roof profile w ithout penetration of the sheeting The opportunity to m ake a feature of the panels by anodising or pow der coating Type of occupancy for part of the building or structure B O ffices and w ork areas not covered elsew here. Exam ples of specific use C atw alks U niform ly distributed load N /A C oncentrated load kN 1kN at 1m centres Type of occupancy for part of the building or structure B and E O ffices and w ork areas not included elsew here, including storage areas. Exam ples of specific use (iii) Light access stairs and gangw ays not m ore than 600m m w ide. H orizontal uniform ly distributed line load (kN /m ) 0.22 A uniform ly distributed load applied to the infill (kN /m ) N /A A point load applied to the infill (kN /m ) N /A E C B A C B A We stro n g ly re co m m e n d th a t th e sp e cia l p u rp o se N E A C O F I XI N G C L A M P B rit. P a te n t N o . 1 4 1 8 7 4 1 ) , illu stra te d h e re , is u se d wh e n se c u rin g N E AC O T E C H D E K to su p p o rtin g ste e l wo rk . T h e N E A C O fixin g sy ste m c o m p rise s se ve ra l p a rts: b o lt in 3 0 4 g ra d e sta in le ss ste e l b o tto m se c u rin g c la m p in sta in le ss ste e l sq u a re n u t in sta in le ss ste e l h o le d rille d u sin g jig sa d d le c la m p in a lu m in iu m a llo y Fixing M ethod The com plete clam p should be loosely assem bled by passing the bolt through the saddle clam p (no saddle clam p required for N eatdek) and bottom securing clam p, running on the nut tw o or three threads. The clam ping assem bly m ay then be fed through the flooring betw een the tw o load-bearing bars and as close as possible to the supporting steelw ork. This operation can be carried out from the top (w orking) surface of the flooring. Slide the clam p assem bly tow ards the steelw ork until the channel-shaped end of the bottom clam p is underneath the steelw ork to its full extent. The bolt should then be fully tightened, ensuring that the square nut is located in the channel of the bottom securing clam p and that the upw ard projecting tongue of this bottom clam p is located betw een tw o of the bearing bars. 31 E A S Y F I X I N G S Y S T E M @ neaconew s E A B C D D Norton Engineering Alloys Company Limited, Norton Grove Industrial Estate, Norton, Malton, N. Yorkshire YO17 9HQ England Tel: 01653 695721 Fax: 01653 600418 E-mail: [email protected] Many of the products of NEACO Ltd. are the subject of world-wide patents, either granted or applied for. Notwithstanding patent protection, NEACO Ltd. reserve full copyright in all components and products, fittings and designs, and will vigorously prosecute all infringements. NEACO is the registered trade name of Norton Engineering Alloys Company Ltd. The words Neatdek and N-I Bar are the copyright of Norton Engineering Alloys Company Ltd. As NEACO products are subject to a continuing process of research and development, the products illustrated in this brochure may be altered without notice. All NEACO products are supplied subject to our Conditions of Sale which are supplied with every quotation. A copy is available on request.
A Practical Workshop Companion for Tin, Sheet Iron, and Copper Plate Workers: Containing Rules for Describing Various Kinds of Patterns used by Tin, Sheet Iron, and Copper Plate Workers, Practical Geometry, Mensuration of Surfaces and Solids, Tables of the Weights of Metals, Lead Pipe, Tables of Areas and Circumferences
Triangulation - Applied to Sheet Metal Pattern Cutting - A Comprehensive Treatise for Cutters, Draftsmen, Foremen and Students: Progressing from the Simplest Phases of the Subject to the Most Complex Problems Employed in the Development of Sheet Metal Patterns with Practical Solutions of Numerous Problems of Frequent Occurrence in Sheet Metal Shops
A Short Guide to the Types and Details of Constructing a Suspension Bridge - Including Various Arrangements of Suspension Spans, Methods of Vertical Stiffening and Wire Cables Versus Eyebar Chains
Kitchen as Laboratory Reflections on the Science of Food and Co Cesar The Vega Cesar & Ubbink Job & van der Linden Erik all chapter instant download