drives are designed to drive brushed and brushless servomotors. These fully digital drives operate in torque, velocity, or position mode and employ Space Vector Modulation (SVM), which results in higher bus voltage utilization and reduced heat dissipation compared to traditional PWM. The drive can be configured for a variety of external command signals. Commands can also be configured using the drives built-in Motion Engine, an internal motion controller used with distributed motion applications. In addition to motor control, these drives feature dedicated and programmable digital and analog inputs and outputs to enhance interfacing with external controllers and devices. This DP Series drive features a single RS-232/RS-485 interface used for drive configuration and setup. Drive commissioning is accomplished using DriveWare
7, available for download at www.a-m-c.com. All drive and motor parameters are stored in non- volatile memory. Peak Current 100 A (70.7 ARMS) Continuous Current 50 A (35.4 ARMS) Supply Voltage 200 - 240 VAC
Features
Four Quadrant Regenerative Operation Space Vector Modulation (SVM) Technology Fully Digital State-of-the-art Design Programmable Gain Settings Fully Configurable Current, Voltage, Velocity and Position Limits PIDF Velocity Loop PID + FF Position Loop Compact Size, High Power Density 16-bit Analog to Digital Hardware Built-in brake/shunt regulator On-the-Fly Mode Switching On-the-Fly Gain Set Switching
MODES OF OPERATION Current Position Velocity Hall Velocity COMMAND SOURCE PWM and Direction Encoder Following Over the Network 10 V Analog 24V Step and Direction Indexing Jogging FEEDBACK SUPPORTED Halls Incremental Encoder 10 VDC Position Auxiliary Incremental Encoder Tachometer (10 VDC) INPUTS/OUTPUTS 3 High Speed Captures 4 Programmable Analog Inputs (16-bit/12-bit Resolution) 3 Programmable Digital Inputs (Differential) 7 Programmable Digital Inputs (Single-Ended) 4 Programmable Digital Outputs (Single-Ended)
COMPLIANCES & AGENCY APPROVALS UL cUL CE Class A (LVD) CE Class A (EMC) RoHS
I n t e r f a c e Drive Logic RS232/485 Interface CONTROL MODULE RX/RX TX+ RX+ ISO GND PAI-1,4 +(REF+) PAI-1,4 (REF) PDI-1,2,3,4,5,6,7 (STEP / DIR / CAP-A) INPUT COMMON PDI-8,9,10 +(PWM+/ DIR+/ AUX ENC A,B +/ CAP-B,C+) PDO-1,2,3,4 OUTPUT COMMON 5k +5V 10k +5V 10k 2.5k 20k 20k 20k PAI-2,3 SGN GND PAI-2: 33k PAI-3: 500k 3.75K PDI-8,9,10 (PWM / DIR / AUX ENC A,B / CAP-B,C) OUTPUT PULL-UP M o t o r
F e e d b a c k M o t o r
F e e d b a c k MOT ENC A,B,I + MOT ENC A,B,I HALL A,B,C + HALL A,B,C 10k +5V 20k +5V 20k +5V 10k +5V 10k 5k ENC A,B,I +OUT ENC A,B,I OUT DC+ MOTOR A MOTOR B MOTOR C POWER MODULE Power Stage Logic Power L1 L2 L3 LOGIC+ LOGIC Shunt Reg. BR
Information on Approvals and Compliances
US and Canadian safety compliance with UL 508c, the industrial standard for power conversion electronics. UL registered under file number E140173. Note that machine components compliant with UL are considered UL registered as opposed to UL listed as would be the case for commercial products.
Compliant with European CE for both the Class A EMC Directive 2004/108/EC on Electromagnetic Compatibility (specifically EN 61000-6-4:2007 and EN 61000-6-2:2005) and LVD requirements of directive 2006/95/EC (specifically EN 60204-1:2006), a low voltage directive to protect users from electrical shock.
RoHS (Reduction of Hazardous Substances) is intended to prevent hazardous substances such as lead from being manufactured in electrical and electronic equipment. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By:
SPECIFICATIONS Power Specifications Description Units Value Rated Voltage VAC (VDC) 240 (339) AC Supply Voltage Range VAC 200 - 240 AC Supply Minimum VAC 180 AC Supply Maximum VAC 264 AC Input Phases 1 - 3 AC Supply Frequency Hz 50 - 60 DC Supply Voltage Range 2 VDC 255 - 373 DC Bus Over Voltage Limit VDC 429 DC Bus Under Voltage Limit VDC 205 Logic Supply Voltage VDC 20 - 30 (@ 850 mA) MaximumPeak Output Current 3 A (Arms) 100 (70.7) MaximumContinuous Output Current A (Arms) 50 (35.4) Max. Continuous Output Power @ Rated Voltage 4 W 11400 Max. Continuous Power Dissipation @ Rated Voltage W 600 Internal Bus Capacitance F 1500 External Shunt Resistor MinimumResistance 5 10 MinimumLoad Inductance (Line-To-Line) 6 H 600 Switching Frequency kHz 16 MaximumOutput PWM Duty Cycle % 100 Low Voltage Supply Outputs - +5 VDC (250 mA) Control Specifications Description Units Value Communication Interfaces - RS-485/232 Command Sources - 10 V Analog, 24V Step and Direction, Encoder Following, Over the Network, PWM and Direction, Indexing, J ogging Feedback Supported - 10 VDC Position, Auxiliary Incremental Encoder, Halls, Incremental Encoder, Tachometer (10 VDC) Commutation Methods - Sinusoidal, Trapezoidal Modes of Operation - Current, Hall Velocity, Position, Velocity Motors Supported - Closed Loop Vector, Single Phase (Brushed, Voice Coil, Inductive Load), Three Phase (Brushless) Hardware Protection - 40+Configurable Functions, Over Current, Over Temperature (Drive & Motor), Over Voltage, Short Circuit (Phase-Phase & Phase-Ground), Under Voltage Programmable Digital Inputs/Outputs (PDIs/PDOs) - 10/4 Programmable Analog Inputs/Outputs (PAIs/PAOs) - 4/0 Primary I/O Logic Level - 24 VDC Current Loop Sample Time s 62.5 Velocity Loop Sample Time s 125 Position Loop Sample Time s 125 MaximumEncoder Frequency MHz 20 (5 pre-quadrature) Internal Shunt Regulator - Yes Internal Shunt Resistor - No Mechanical Specifications Description Units Value Agency Approvals - CE Class A (EMC), CE Class A (LVD), cUL, RoHS, UL Size (H x W x D) mm(in) 272.8 x 230.4 x 149.4 (10.7 x 9.1 x 5.9) Weight g (oz) 5500 (194) Heatsink (Base) Temperature Range 7 C (F) 0 - 75 (32 - 167) Storage Temperature Range C (F) -40 - 85 (-40 - 185) FormFactor - Panel Mount Cooling System - Forced Convection IP Rating - IP10 AUX ENCODER Connector - 15-pin, high-density, male D-sub BRAKE/LOGIC Connector - 4-contact, 13 mmspaced, dual-barrier terminal block COMM Connector - 9-pin, female D-sub FEEDBACK Connector - 15-pin, high-density, female D-sub I/O Connector - 26-pin, high-density, female D-sub MOTOR POWER Connector - 4-contact, 13 mmspaced, dual-barrier terminal block POWER Connector - 4-contact, 13 mmspaced, dual-barrier terminal block Notes 1. Can operate on single-phase VAC if peak/cont. current ratings are reduced by at least 30%. 2. DC Supply operation will reduce peak/cont. current ratings by at least 30%. 3. Capable of supplying drive rated peak current for 2 seconds with 10 second foldback to continuous value. Longer times are possible with lower current limits. 4. P = (DC Rated Voltage) * (Cont. RMS Current) * 0.95. 5. ADVANCED Motion Controls recommends using an external fuse in series with the the shunt resistor. A 3 amp motor delay fuse is typical. 6. Lower inductance is acceptable for bus voltages well below maximum. Use external inductance to meet requirements. 7. Additional cooling and/or heatsink may be required to achieve rated performance. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By:
PIN FUNCTIONS AUX ENCODER - Auxiliary Feedback Connector Pin Name Description / Notes I/O 1 RESERVED Reserved - 2 RESERVED Reserved - 3 RESERVED Reserved - 4 PDI-8 +(PWM+/ AUX ENC A+/ CAP-B+) Programmable Digital Input or PWM or Auxiliary Encoder or High Speed Capture (For Single-Ended Signals Leave Negative Terminal Open) I 5 PDI-8 - (PWM- / AUX ENC A- / CAP-B-) I 6 PDI-9 +(DIR+/ AUX ENC B+/ CAP-C+) Programmable Digital Input or Direction Input or Auxiliary Encoder or High Speed Capture (For Single-Ended Signals Leave Negative Terminal Open) I 7 PDI-9 - (DIR- / AUX ENC B- / CAP-C-) I 8 PDI-10 + Programmable Digital Input (For Single-Ended Signals Leave Negative Terminal Open) I 9 PDI-10 - I 10 SGN GND Signal Ground SGND 11 SGN GND Signal Ground SGND 12 SGN GND Signal Ground SGND 13 +5V OUT +5V Encoder Supply Output (Short Circuit Protected) O 14 PAI-4 + Differential Programmable Analog Input (12-bit Resolution) I 15 PAI-4 - I
BRAKE/LOGIC - Logic Power Connector Pin Name Description / Notes I/O 1 LOGIC GND Logic Supply Ground GND 2 LOGIC PWR Logic Supply Input I 3 BR External Brake Resistor Connection - 4 DC+ Brake Resistor DC+. Connection for brake resistor. O
COMM - RS232/RS485 Communication Connector Pin Name Description / Notes I/O 1 SELECT RS232/485 selection. Pull to ground (CN1-5) for RS485. I 2 RS232 TX / RS485 TX- Transmit Line (RS-232 or RS-485) O 3 RS232 RX / RS485 RX- Receive Line (RS-232 or RS-485) I 4 RESERVED Reserved - 5 ISO GND Isolated Signal Ground IGND 6 RS485 TX+ Transmit Line (RS-485) O 7 RESERVED Reserved - 8 RS485 RX+ Receive Line (RS-485) I 9 RESERVED Reserved -
FEEDBACK - Feedback Connector Pin Name Description / Notes I/O 1 HALL A+ Commutation Sensor Inputs I 2 HALL B+ I 3 HALL C+ I 4 MOT ENC A+ Differential Encoder A Channel Input (For Single Ended Signals Use Only The Positive Input) I 5 MOT ENC A- I 6 MOT ENC B+ Differential Encoder B Channel Input (For Single Ended Signals Use Only The Positive Input) I 7 MOT ENC B- I 8 MOT ENC I+ Differential Encoder Index Input (For Single Ended Signals Use Only The Positive Input) I 9 MOT ENC I- I 10 HALL A- Commutation Sensor Input (For Differential Signals Only) I 11 HALL B- Commutation Sensor Input (For Differential Signals Only) I 12 SGN GND Signal Ground SGND 13 +5V OUT +5V Encoder Supply Output (Short Circuit Protected) O 14 PAI-3 Programmable Analog Input (12-bit Resolution) I 15 HALL C- Commutation Sensor Input (For Differential Signals Only) I
I/O - Signal Connector Pin Name Description / Notes I/O 1 PDO-1 Isolated Programmable Digital Output O 2 OUTPUT COMMON Digital Output Common OGND 3 PDO-2 Isolated Programmable Digital Output O 4 PAI-1 +(REF+) Differential Programmable Analog Input or Reference Signal Input (16-bit Resolution) I 5 PAI-1 - (REF-) I 6 PAI-2 Programmable Analog Input (12-bit Resolution) I 7 SGN GND Signal Ground SGND 8 OUTPUT PULL-UP Digital Output Pull-Up For User Outputs I 9 PDI-5 Isolated Programmable Digital Input I 10 PDO-3 Isolated Programmable Digital Output O 11 PDI-1 Isolated Programmable Digital Input I 12 PDI-2 Isolated Programmable Digital Input I 13 PDI-3 Isolated Programmable Digital Input I 14 PDO-4 Isolated Programmable Digital Output O 15 INPUT COMMON Digital Input Common (Can Be Used To Pull-Up Digital Inputs) IGND 16 SGN GND Signal Ground SGND 17 PDI-4 (STEP) Isolated Programmable Digital Input or Step I 18 PDI-6 (DIR) Isolated Programmable Digital Input or Direction I 19 PDI-7 (CAP-A) Isolated Programmable Digital Input or High Speed Capture I 20 ENC A+OUT Buffered Encoder Channel A Output O 21 ENC A- OUT O 22 ENC B+OUT Buffered Encoder Channel B Output O 23 ENC B- OUT O 24 ENC I+OUT Buffered Encoder Index Output O 25 ENC I- OUT O 26 SGN GND Signal Ground SGND
MOTOR POWER - Motor Power Connector Pin Name Description / Notes I/O 1 SHIELD Motor cable shield. Internally connected to protective earth ground. - 2 MOTOR POWER U Motor Phase U O 3 MOTOR POWER V Motor Phase V O 4 MOTOR POWER W Motor Phase W O
POWER - AC Power Connector Pin Name Description / Notes I/O 1 L1 AC Supply Input (Three Phase) I 2 L2 I 3 L3 I 4 PE Protective Earth Ground - ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By:
HARDWARE SETTINGS Switch Functions Switch Description Setting On Off 1 Bit 0 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 2 Bit 1 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 3 Bit 2 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 4 Bit 3 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 5 Bit 4 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 6 Bit 5 of binary RS-485 drive address. Does not affect RS-232 settings. 1 0 7 Bit 0 of drive RS-485 baud rate setting. Does not affect RS-232 settings. 1 0 8 Bit 1 of drive RS-485 baud rate setting. Does not affect RS-232 settings. 1 0 Additional Details The drive can be configured to use the address and/or bit rate stored in non-volatile memory by setting the address and/or bit rate value to 0. Use the table below to map actual bit rates to a bit rate setting.
Baud Rate (kbps) Value For Bit Rate Setting Load from non-volatile memory 0 9.6 1 38.4 2 115.2 3 ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By:
MECHANICAL INFORMATION AUX ENCODER - Auxiliary Feedback Connector Connector Information 15-pin, high-density, male D-sub Mating Connector Details TYCO: Plug P/N 1658681-1; Housing P/N 5748677-1; Terminals P/N 1658686-2 (loose) or 1658686-1 (strip) Included with Drive No PDI-8 - (PWM- / AUX ENC A- / CAP-B-) 5 PDI-8 +(PWM+/ AUX ENC A+/ CAP-B+) 4 PAI-4 - 15 PAI-4 + 14 +5V OUT 13 SGN GND 12 SGN GND 11 SGN GND 10 PDI-9 +(DIR+/ AUX ENC B+/ CAP-C+) 6 PDI-10 - 9 PDI-10 + 8 PDI-9 - (DIR- / AUX ENC B- / CAP-C-) 7
BRAKE/LOGIC - Logic Power Connector Connector Information 4-contact, 13 mm spaced, dual-barrier terminal block Mating Connector Details Not applicable Included with Drive Not applicable LOGIC GND 1 LOGIC PWR 2 BR 3 DC+ 4
COMM - RS232/RS485 Communication Connector Connector Information 9-pin, female D-sub Mating Connector Details TYCO: Plug P/N 205204-4; Housing P/N 5748677-1; Terminals P/N 1658540-5 (loose) or 1658540-4 (strip) Included with Drive No SELECT 1 RS232 TX / RS485 TX- 2 RS232 RX / RS485 RX- 3 ISO GND 5 RS485 TX+ 6 RS485 RX+ 8
FEEDBACK - Feedback Connector Connector Information 15-pin, high-density, female D-sub Mating Connector Details TYCO: Plug P/N 748364-1; Housing P/N 5748677-1; Terminals P/N 1658670-2 (loose) or 1658670-1 (strip) Included with Drive No HALL A+ 1 HALL B+ 2 HALL C+ 3 MOT ENC A+ 4 MOT ENC A- 5 HALL B- 11 SGN GND 12 +5V OUT 13 PAI-3 14 HALL C- 15 MOT ENC B+ 6 HALL A- 10 MOT ENC B- 7 MOT ENC I+ 8 MOT ENC I- 9
I/O - Signal Connector Connector Information 26-pin, high-density, female D-sub Mating Connector Details TYCO: Plug P/N 1658671-1; Housing P/N 5748677-2; Terminals P/N 1658670-2 (loose) or 1658670-1 (strip) Included with Drive No PDO-1 1 2 3 4 5 6 8 9 7 PDO-4 14 PDI-1 11 PDI-2 12 PDI-3 13 PDO-3 10 INPUT COMMON 15 PDI-4 (STEP) 17 PDI-6 (DIR) 18 SGN GND 16 OUTPUT COMMON PDI-5 OUTPUT PULL-UP SGN GND PAI-2 PAI-1 - (REF-) PAI-1 +(REF+) PDO-2 PDI-7 (CAP-A) 19 ENC I+OUT 24 ENC B+OUT 22 ENC A+OUT 20 ENC A- OUT 21 ENC B- OUT 23 ENC I- OUT 25 SGN GND 26
MOTOR POWER - Motor Power Connector Connector Information 4-contact, 13 mm spaced, dual-barrier terminal block Mating Connector Details Not applicable Included with Drive Not applicable SHIELD 1 MOTOR POWER U 2 MOTOR POWER V 3 MOTOR POWER W 4
POWER - AC Power Connector Connector Information 4-contact, 13 mm spaced, dual-barrier terminal block Mating Connector Details Not applicable Included with Drive Not applicable L1 1 L2 2 L3 3 PE 4
PART NUMBERING INFORMATION - Drive Series DigiFlex Performance Communication Command Inputs R P D I N A E 5 1 0 A 0 0 4 Example: DP RS232/RS485 R CANopen or RS232 C SynqNet Q Analog (10V) No Step &Direction AN Analog (10V) Low Voltage Step &Direction (5V) AL Analog (10V) High Voltage Step &Direction (24V) AH No Analog Low Voltage Step &Direction (5V) NL No Analog, No Step &Direction (Communication Interface Only) NN Digital I/O Isolated (24V) I TTL (5V) Non-Isolated T Motor Feedback Incremental Encoder and/or Halls E Resolver R Absolute Sin/Cos (Hiperface &Endat) A Sin/Cos with Halls S Max DC Bus Voltage (VDC) 80 080 200 200 400 400 800 800 AC Input +24VDC User Logic Supply Required A AC Input Single Phase Only +24VDC User Logic Supply Required S DC Input Both Logic Supply Options (Internal or User) B DC Input Logic Supply Required L 15 015 16 016 20 020 25 025 30 030 40 040 60 060 100 100 - Code used to identify customer specials Power and Logic Supply Peak Current (A0 to Peak) Customer Special EtherCAT E Universal (Halls, Inc. Enc., Abs. Enc., 1Vp-p Sin/Cos Enc.) U
DigiFlex Performance series of products are available in many configurations. Note that not all possible part number combinations are offered as standard drives. All models listed in the selection tables of the website are readily available, standard product offerings.
ADVANCED Motion Controls also has the capability to promptly develop and deliver specified products for OEMs with volume requests. Our Applications and Engineering Departments will work closely with your design team through all stages of development in order to provide the best servo drive solution for your system. Equipped with on-site manufacturing for quick- turn customs capabilities, ADVANCED Motion Controls utilizes our years of engineering and manufacturing expertise to decrease your costs and time-to-market while increasing system quality and reliability. Feel free to contact Applications Engineering for further information and details.
Examples of Customized Products Optimized Footprint Tailored Project File Private Label Software Silkscreen Branding OEM Specified Connectors Optimized Base Plate No Outer Case Increased Current Limits Increased Current Resolution Increased Voltage Range Increased Temperature Range Conformal Coating Custom Control Interface Multi-Axis Configurations Integrated System I/O Reduced Profile Size and Weight
All specifications in this document are subject to change without written notice. Actual product may differ from pictures provided in this document. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By: