Model Ut51-55: Operating Manual: Downloaded From Manuals Search Engine
The document provides instructions for operating a UNI-T brand multimeter. It includes:
1) An introduction describing the multimeter's features such as measuring DC and AC current/voltage, resistance, capacitance, temperature, and frequency.
2) Safety rules for operating the multimeter such as ensuring proper connections, not exceeding voltage limits, replacing batteries when low, and avoiding humid environments.
3) Specification tables listing the measurement ranges and accuracy of the multimeter's functions.
4) Steps for making measurements of voltage, current, resistance, capacitance, and other quantities.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
289 views
Model Ut51-55: Operating Manual: Downloaded From Manuals Search Engine
The document provides instructions for operating a UNI-T brand multimeter. It includes:
1) An introduction describing the multimeter's features such as measuring DC and AC current/voltage, resistance, capacitance, temperature, and frequency.
2) Safety rules for operating the multimeter such as ensuring proper connections, not exceeding voltage limits, replacing batteries when low, and avoiding humid environments.
3) Specification tables listing the measurement ranges and accuracy of the multimeter's functions.
4) Steps for making measurements of voltage, current, resistance, capacitance, and other quantities.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20
Contents
A Your Meters Feature
B Specifications C Making Measurements D Maintenance E Accessories F Using Holster G Using Strap Introduction One kind of UNI-T brand new UT50 series Multimeters is a 3 1/2 digit with steady function and highly reliable hand-held measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. The Meter can measure DC current, AC current, DC Voltage, AC Voltage, Resistance, Capacitance, Diode, Temperature, Frequency and Continuity, which is an ideal tool for users. Model UT51-55: OPERATING MANUAL 1 Downloaded from www.Manualslib.com manuals search engine Safety Rules l Do not operate the Meter before the cabinet has been closed and screwed safely as terminal can carry voltage. l Make sure before each measurement the Meter is set to the suitable range. l Before using the Meter, please inspect the cabinet and test leads for damaged insulation or exposed metal. l Connect the red and black test lead to the correct measuring input jack properly. l Do not input values over the maximum range of each measurement to avoid damages of the Meter. l The UNI-T UT50 series comply with IEC 61010: in pollution degree 2, overvoltage category (CAT I 1000V and CAT II 600V) and double insulation. Use the Meter only as specified in this manual, otherwise the protection provided by the Meter may be impaired. l CAT I-For signal level, telecommunication, electronic with small transient over voltage. l CAT II -For local level, appliances, main wall outlets, portable equipment. l The meter is designed to withstand the stated Max. voltages. If its not possible to exclude without doubts that impulses, transients, disturbance or for other reasons, these voltages are exceeded a suitable prescale (10:1) must be used. l Do not turn the rotary function switch during Voltage and Current measurement, otherwise the Meter could be destroyed. Model UT51-55: OPERATING MANUAL 2 Downloaded from www.Manualslib.com manuals search engine l Replace the battery as soon as the battery indicator " " appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. l Turn off the Meter once finished measuring, fetch out the battery, when the meter will not be used for long period. l Do not operate the Meter under adverse environmental condition especially humid area. l To avoid damages and dangerous, do not change the circuit. l Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. l International Electrical Symbols: Low Battery Earth Ground Safety Rules Double Insulated AC Diode Dangerous Voltages DC Buzzer Fuse l Make sure to use new fuses with proper rating in stead of bad fuses . l To avoid electric shock or damages, do not apply more than 1000V between the "COM" terminals and" "earth ground. l Use caution when working with Voltages above 60V (DC) or 30Vrms (AC). These Voltages pose shock hazard. l The Meter is suitable for indoor use only. Model UT51-55: OPERATING MANUAL 3 Downloaded from www.Manualslib.com manuals search engine A. Your Meters Feature l 32 ranges. l Liquid Crystal Display, digits height is 27mm. l Overload display l. l Maximum display 1999 (3 1/2 digit). l Full range overload protection. l Auto-Power Off (For UT53, UT54 and UT55 ONLY). l Temperature: Operating:0 o C to 40 o C (32 0 F to 104 0 F). Storing:-10 o C to 50 o C (14 0 F to 122 0 F ). l Altitude: Operating: 2000m Storing: 10000m. l Relative Humidity:Max. relative humidity 80% for temperature up to 31 o C decreasing linearly to 50% relative humidity at 40 o C. l Low Battery display " " . l Strap for easy carry. l Tilt stand design, three observation angles, is in favor of reading display. l Dimension: 190mm x 88mm x 34mm. l Weight: Meter only(excluding test leads) about 270g .Meter + holster + tilt stand about 550g. l Battery Type: 9V NEDA 1604 or 6F22 or 006P Model UT51-55: OPERATING MANUAL 4 Downloaded from www.Manualslib.com manuals search engine B. Specifications Accuracy is specified for one year after calibration, at operating temperatures 23 o C +/- 5 o C, with relative humidity at < 75%.Accuracy specifications take the form of:+/- (a% readings +digits ) B-1Direct Current Voltage (DC Voltage) Input impedance: All ranges are 10M . Overload protection: 200mV is 250VDC or AC RMS. All other ranges is 750Vrms or 1000Vp-p. B-2 Alternating Current Voltage (AC Voltage) Input impedance: All ranges are 10M. Frequency: 40Hz-400Hz . Overload protection: 200mV is 250VDC or AC RMS. All other ranges is 750Vrms or 1000Vp-p. Display: Average Value (RMS of Sine Wave). 200mV 2V 20V 200V 1000V 100V 1mV 10mV 100mV 1V Range Resolution (0.5% +1) UT51 UT 52 UT53 UT54 UT55 Accuracy (0.8% +2) 200mV 2V 20V 200V 750V 100V 1mV 10mV 100mV 1V Range Resolution UT51 UT 52 UT53 UT54 UT55 Accuracy (1.2% +3) (0.8% +3) (1.2% +3) Model UT51-55: OPERATING MANUAL 5 Downloaded from www.Manualslib.com manuals search engine B-3 Direct Current Current (DC Current) Overload protection: 20A 200A 2mA 20mA 200mA 2A 10A 20A 0.01A 0.1 A 1 A 10A 100 A 1mA Range Resolution UT51 UT 52 UT53 UT54 UT55 Accuracy (2%+5) (0.8%+1) (1.5%+1 ) (0.8%+1) 10mA (1.5%+1) (2%+5) (2%+5 ) For UT51: 2A, 250V fast acting fuse, 5x20mm(below 2A range) 10A, 250V fast acting fuse,5x20mm(at 10A range) . For UT52/53/54/55: 315mA, 250V fast acting fuse, 5x20mm (No fuse at 20A range). Max current input : For UT51: 10A (The measurement time for high current should be less than 10 seconds maximum, and the interval time between two measurements should be greater than 15 minutes. For UT52/53/54/55: 20A (The measurement time for high current should be less than 15 seconds maximum, and the interval time between two measurements should be greater than 15 minutes. Model UT51-55: OPERATING MANUAL 6 Downloaded from www.Manualslib.com manuals search engine 7 B-4 Alternating Current Current (AC Current) 200A 2mA 20mA 200mA 2A 10A 20A 0.1A 1A 10A 100 A 1mA Range Resolution UT51 UT 52 UT53 UT54 UT55 Accuracy (1%+3) (1%+3) 10mA (1.8%+3) (3%+7) (3%+7 ) (1.8%+3) (1.8%+3) Overload protection: For UT51: 2A, 250V fast acting fuse, 5x20mm(below 2A range) 10A, 250V fast acting fuse,5x20mm(at 10A range) . For UT52/53/54/55: 315mA, 250V fast acting fuse,5x20mm (No fuse at 20A range). Max current input : For UT51: 10A (The measurement time for high current should be less than 10 seconds maximum, and the interval time between two measurements should be greater than 15 minutes. For UT52/53/54/55: 20A (The measurement time for high current should be less than 15 seconds maximum, and the interval time between two measurements should be greater than 15 minutes. Measuring voltage drop: Full range is 200mV. Display: Average Value (RMS of Sine Wave ) . Model UT51-55: OPERATING MANUAL Downloaded from www.Manualslib.com manuals search engine B- 6 Capacitance Testing signal: around 400Hz 40mVrms Range Resolution UT51 UT 52 UT53 UT54 UT55 Accuracy (4% +3) 2nF 20nF 200nF 2F 20F 1pF 10pF 100pF 1nF 10nF B-5 Resistance 200 2K 20K 200K 2M 20M 200M 0.1 1 10 100 1K 10K 100K Range Resolution UT51 UT 52 UT53 UT54 UT55 Accuracy (0.8% +1) (0.8% +3) (1% +2) [5%(-10) +10] B-7 Frequency Range Resolution UT51 Accuracy UT52 UT54 UT55 UT53 2kHz 20kHz 1Hz 10Hz (2%+5) (1.5%+5) Voltage at open circuit: 700mV (200M range, open circuit voltage around 3V) . Overload protection: All ranges 250VDC or AC RMS . Caution: At 200M range, as test lead is short circuit the LCD display 10 digits is normal, deduct the 10 digits from the measured reading during measuring. Model UT51-55: OPERATING MANUAL 8 Downloaded from www.Manualslib.com manuals search engine Overload protection: 250V DC or AC RMS. B-10 Transistor hFE test Comment Measuring Condition Range hFE Can measure NPN or PNP transistor hFE. Range: 0-1000 Basic polarity current abt 10A,Vce abt 2.8V B-9 Diode Test and Continuity Beeper Comment Measuring Condition Range Display diode forward- voltage near value, Unit mV Forward DC current abt 1mABackward DC voltage abt 2.8V Voltage at open circuit abt 2.8V
B-8 Temperature Range Resolution Accuracy UT51,52,53 UT53 UT55 (5%+3) (1%+3) 2% -20 o C to 1000 o C 1 o C -20 o C to 0 o C 0 o C to 400 o C 400 o Cto 1000 o C Input sensitivity: 100mVrms. Overload protection: 250Vrms. Model UT51-55: OPERATING MANUAL 9 Downloaded from www.Manualslib.com manuals search engine C. Making Measurements
1 On/Off Switch 2 Capacitance jack 3 Liquid Crystal Display 4 Temperature jack 5 Rotary switch 6 Transistor jack 7 Input jack Model UT51-55: OPERATING MANUAL 10 Downloaded from www.Manualslib.com manuals search engine Caution
Caution
Model UT51-55: OPERATING MANUAL 11 Downloaded from www.Manualslib.com manuals search engine
Caution
1) Please refer to DC Current Caution 1, 2, 3. Caution
Model UT51-55: OPERATING MANUAL 12 Downloaded from www.Manualslib.com manuals search engine
C-5 Measuring Resistance
Caution
C-6 Measuring Capacitance Before measuring capacitance, remember it takes time for zeroing when changing ranges. Floating reading does not effect accuracy. 1) To avoid damage of the Meter or the equipment under testing, disconnect circuit powers and discharge capacitors before measuring capacitance. 2) Connect capacitor to the capacitance jack. 3) Stabilizing reading takes some time when measuring high capacitance. 4) Unit: 1pF=10 -6 F, 1nF = 10 -3 F Model UT51-55: OPERATING MANUAL 13 Downloaded from www.Manualslib.com manuals search engine C-7 Measuring Frequency
Model UT51-55: OPERATING MANUAL 14 Downloaded from www.Manualslib.com manuals search engine 15 D. Maintenance I. General Service
Model UT51-55: OPERATING MANUAL Downloaded from www.Manualslib.com manuals search engine 2. Turn the Meter power OFF 3. Remove the holster from the Meter. 4. Remove rubber feet and screws from the case bottom, and separate the case bottom from the case top. 5. Remove the battery from the battery compartment. 6. Replace the battery with a new 9V battery (NEDA 1604 or 6F22 or 006P). 7. Rejoin the case bottom and case top, and install the screws and rubber feet. III.Replacing the Fuses To avoid electrical shock or arc blast, or personal injury or damage to the Meter, use specified fuses ONLY in accordance with the following procedure. To replace the Meters fuse: 1. Disconnect the connection between the testing leads and the circuit under test, and remove the testing leads away from the input terminals of the Meter. 2. Turn the Meter power OFF. 3. Remove the rubber feet and screws from the case bottom, and separate the case bottom from the case top. 4. Remove the fuse by gently prying one end loose, and then take out the fuse from its bracket. 5. Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fixed firmly in the bracket. UT51: 2A, 250V fast acting fuse,5x20mm (below 2A range) 10A, 250V fast acting fuse,5x20mm (at 10A range) Caution Model UT51-55: OPERATING MANUAL 16 Downloaded from www.Manualslib.com manuals search engine F. Using Holster Three different ways to use holster: 1. Set holster parallel on the table, do not open the tilt stand (see diagram 1). 2. Set holster in a small angle on the table, tilt it up by the first part of tilt stand (see diagram 2) 3. Set holster in a large angle on the table, tilt it up by all two parts of tilt stand (see diagram 3). figure1 figure2 figure3 E. Accessories 1. A book of users manual 2. A pair of test lead 3. A pair of WRN-01B bread temperature probe (for UT53 and UT55 ONLY) 4. A piece of holster (if selected) 17 UT52/53/54/55: 315mA, 250V fast acting fuse, 5x20mm 6. Rejoin the case bottom and the case top, and install the screw and rubber feet Replacement of fuses is seldom required. Burning of a fuse always results from the improper operation. Model UT51-55: OPERATING MANUAL Downloaded from www.Manualslib.com manuals search engine ~ END ~ * The manual is subject to changes without separate notice. * G. Using Strap 1. Put the front end of the strap through the round metal of the Meter, see part 1 of the below diagram. 2. Put the bottom end of the strap through the front part and tide it up, see part 2 of the below diagram. Model UT51-55: OPERATING MANUAL 18 Downloaded from www.Manualslib.com manuals search engine 19 Model UT51-55: OPERATING MANUAL Downloaded from www.Manualslib.com manuals search engine Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITED Address: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Men Town, Dong Guan City, Guang Dong Province, China Headquarters: Uni-Trend International Limited Address: Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: [email protected] http://www.uni-trend.com Model UT51-55: OPERATING MANUAL 20 Downloaded from www.Manualslib.com manuals search engine