Labcycler Instruction Manual
Labcycler Instruction Manual
Hannah-Vogt-Str. 1
D-37085 Goettingen, Germany
Tel +49(0)551-389195-23, +49(0)551-250-3244
Fax +49(0)551-389195-24
[email protected]
www.sensoquest.com
Instruction Manual for the Labcycler
Version: English 2.2
2
Basics
0.0 General Safety Instruction. 4
1.1 Introduction 5
1.2 Operating - Elements of the Labcycler 5
1.3 Set up..... 5
1.4 Power Supply. 6
1.5 Initial Start up ... 6
1.6 Language Set up ... 7
1.7 Time and Date Set up 7
1.8 Online- Help... 8
1.9 Window- Structure. 8
Directory
2.1 Directory New 9
2.2 File Edit.. 10
2.3 File Copy............ 11
2.4 File Delete.. 11
Program
3.1 Program New.... 12
3.1.1 Temperature Gradients.. 14
3.1.2 Heating and Cooling Temperature: Ramp 15
3.1.3 Temperature In(de)crements [dT].. 16
3.1.4 Time In(de)crements [dt].. 17
3.2 Program Edit.. 18
3.3 Program Copy.... 19
3.4 Program Delete.. 19
3.5 Program Start..... 20
3.6 Program Stop. 21
3.7 Program Pause (manual) 22
3.8 Program Pause (hard coded). 22
3.9 Program Continue after Power Failure (Re-Start). 23
3.10 Program Reports 23
3.11 Online Monitoring 23
3
Maintenance and Cleaning
4.1 Block Removal... 24
4.2 Heated Lid. 25
4.3 Opening of the Labcycler in Case of an Emergency 25
4.4 Cleaning. 26
4.5 Reaction Tubes and Compatibility.... 27
4.6 Safety Instructions. 28
4.7 Warranty.... 28
4.8 Technical Data... 29
5.1 General User Management 30
5.2 Set Up User Management.. 30
5.3 General User Management 31
5.4 Changing Administrator Password 32
5.5 Changing Administrator Properties... 32
5.6 Deletion of User Management... 33
5.7 The User or the Standard User... 34
5.8 User Set Up 34
5.9 User Log In & Log Out. 35
5.10 Changing User Properties.. 36
5.11 User Deletion. 36
5.12 User Password Changing... 37
5.13 Protection of Data.. 38
5.14 Remote Log In & Data Transfer between 2 Labcyclers 39
6.1 Order Information.. 41
7.1 Index.. 42
4
0.0 General Safety Instructions
The Labcycler may only used for the intended purpose as detailed in the instruction
manual, after familiarization with it.
Wear safety gloves against heat if you work with the Labcycler. Especially the
passive lids can store heat.
Use the Labcycler only in closed rooms with normal air humidity. Let no liquids
inside the device.
No objects should be left inside the device because these can get into contact with
electrically loaded parts or block movable sections.
Do never touch hot parts of the Labcycler, especially the heating surface at the lid or
the blocks.
Do not touch mobile parts like the active lid or the ventilation.
The Labcycler has parts which are under high voltage. Attention! The instrument
contains high- voltage capacitors which can still be charged to dangerous voltage even
a long time after unplugging. Only trained expert persons may open the device.
Pull the net plug before cleaning. The device must cool down 30 minutes before it
can be purified.
Defect devices must be sent to the manufacturer or a service company which is
licensed by SensoQuest.
Chemical, radioactive or biologic contaminated devices may not be sent to the
manufacturer.
5
1.1 Introduction
Thank you very much for purchasing the Labcycler. Please, follow the security tips and the regulations
of the instruction manual. Each Labcycler is supplied with a mains cable and an instruction manual.
The Labcycler was developed to operate biochemical thermal processes in tubes of the size 0.5 ml, 0.2
ml, 96 microtiterplates as well as 384 microtiterplates. The Labcycler has a TFT-touch screen. On
connecting the device you find at the top left corner of the touch screen a help function [?] which
shows the following steps. In the baseboard below on the right you find another help function which
can be accessed by tapping. The contents of this help function are comparable with the contents of the
instruction manual.
1.2 Operating - Elements of the Labcycler Basic and Gradient
Operating-elements of the front and upper side Operating-elements of the back
1 Numeric keyboard 6 Main switch
2 TFT-display with touch screen 7 Primary fuses
3 Lid-unbolting-key 8 Power plug
4 Block-unbolting-handle 9 Aux - Interface
5 Plug for external sensor 10 PC - Interface
The Operating-elements of Labcycler 48 are similar to Labcycler Basic and Gradient. But, there is no numeric
keyboard (1), no lid-unbolting-key (2) because the Labcycler 48 has no block changing system, and no plug for
an external sensor (5).
1.3 Set up
If the Labcyler is moved from a cold place to a warmer room, it must not be used for 3 hours
to enable any condensing humidity to evaporate.
The Labcycler should be placed upon a hard flat surface e.g. a table.
10 cm space behind the device is necessary.
Paper, foils, or comparable materials must not be located under the Labcycler.
There must be enough space at the top of the device to open the lid.
6
1.4 Power Supply
Connect the Labcycler to a power outlet.
The line voltage of Labcycler Basic and Gradient must be 85 V up to 265 V, for Labcycler 48 200 V
up to 265 with a frequency of 50 Hz to 60 Hz. It is not necessary to make any change-over.
1.5 Initial Start up
1. Put the net cable in the net socket [see operating elements Labcycler (8)] which is on the back
of the device and the plug in the outlet.
2. Operate the mains switch (6) which is on the back part of the device (position 0 = out; position
I = on).
3. The Labcycler carries out a self-test which can be tracked by starting a blue bar.
4. There appears the start window: Block Monitor
5. The Labcycler has a touch screen. The menu strips as well as the input fields are servable with
the fingers or a touch-pen.
6. The servable virtual keys are at the bottom of the window: Files, Run, Options, Help
The upper area of the window shows the information: temperature, lid-temperature,
block, date, and status. ? is a help function and is also servable.
7. Now the device is ready for the input of data.
TFT screen after initial start up of the Labcycler
Start window: Labcycler Triple Block (3x21 wells)
Servable menu bar (touch-field) Servable menu bar (touch-field)
Info
Lid Temp Overview
? Block Monitor Date
Files Run Otions Help
Block 1 Block 2 Block 3
Block 3x21
Graphic
Ready
Temp
Ready
Temp
Ready
Temp
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
7
1.6 Language Set up & Name of Labcycler
The Labcycler operates a binary voice system: English or German.
1. Touch lightly in the menu strip of Options.
2. There appears another menu strip.
3. Tap on Settings.
4. There appears a new window: Settings.
5. Tap on the circle in front of one flag. Choose a
language. Tap in the white field. There appears the
alphabet. The length of the name can be
11 letters.
6. Tap on Save.
7. Tap on Close.
1.7 Time and Date Set up
The new Labcycler has the up to date time and date.
1. Touch lightly in the menu strip of Options.
2. There appears another menu strip.
3. Tap on Settings.
4. There appears a new window: Settings.
5. Tap on Time.
6. Tap on the date or time field.
7. The new input is confirmed by typing Enter.
8. Tap on Save.
9. Tap on Close.
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
Settings
Remote Log In
Remote Log Out
Diagnosis
Language
? Settings
Files Run Options Help
General Time Users
Save
Close
English
German
Device
Input name
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
Settings
Remote Log In
Remote Log Out
Diagnosis
min
Date
? Settings
Files Run Options Help
General Time Users
Save
Close
Time h s
Day Month Year
8
1.8 Online- Help
Two different help functions are available:
1. The icon [?] at the left upper corner indicates possible next actions.
2. The button Help in the lower menu bar opens a submenu with following themes:
Whats this: Indicates forthcoming operation possibilities.
Contents: Provides an overview concerning the help library subdivisions: About this
help library, control elements, block monitor, menu files, menu run, menu options,
and menu help.
About: Supplies Labcycler information.
1.9 Window- Structure
1. The main window Block Monitor contains all important information about the block. It is
always open and stays in the background. All data are updated continuously even if the
window is overlaid by other windows. When the block is running the step listing of the active
program or the temperature graph will be shown.
2. Depending on the operation, other windows are open which overlay the main window, e.g.
writing a new program. The different windows are explained in the following chapters of the
instruction manual.
You can move the windows:
Moving: Tap on the blue menu bar and move your finger during touching the screen.
The window will follow your finger until you release the window.
Scaling down: Tap on the [-] icon. The window is reduced on the size of the title strip.
Tap once more on the icon and the window will appear.
Closing: Tap on the [X] icon and you will close the window. The windows have also
a key Close with the same function.
3. Error window: If you put in values which are out of the limit, the error window will appear. It
informs you concerning the valid range of data.
4. Scroll bar: You can move the window contents with the scroll bars. There are the following
possibilities:
Tap on the bar and move without releasing.
It is much faster to tap on the scroll bar. The bar is shifted, and the window content is
accordingly displayed.
The contents are shifted around exactly on position after typing an arrow key of the
scroll bar.
9
2.1 Directory New
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on New.
4. There appears another menu strip with the functions:
Directory, Program
5. Tap on Directory.
6. There appears a new window: Edit directory name
7. Admit the characters of the folder using the alphabet letters of the touch screen.
8. Ten characters are maximal possible:
The first letter is automatically capitalized.
Capitalization and use of small letters are controlled by the option fields ABC and abc.
Natural numbers can be put in using the numerical keyboard or the option field special.
The option field special contains special characters like dot, comma, plus, minus, and
so on.
8. Confirm the new name with Enter. It appears a new window: Edit directory
9. Please, determine with the icon Group, Person, or Folder the directory ranking.
You can enter a comment of 30 letters.
10. Tap on Save.
11. There appears a new window: Select target directory
12. Tap on the selected directory (folder, person,
group). It will be underlined in blue.
13. Tap on Save.
14. Tap on Close.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
Directory
Program
? Select target directory
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Save
Cancel
10
2.2 File Edit
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on Edit.
4. There appears a new window: Edit
5. Tap on the file you are interested in. This file
is marked blue.
On the left of group, person, or folder there will be a [+] or [-] sign.
Typing on [+] opens the file, type on [-] closes the file.
6. Tap on Edit and you can change the information.
7. Tap on Save.
8. Tap on Close.
2.3 File Copy
Two devices can be connected with a cable. All files appear in green letters. Only the files in green
letters can be copied to the device of origin.
1. Tap on the menu strip Files.
2. There appears another menu strip with the
functions: New, Edit, Copy and Delete
3. Tap on Copy.
4. There appears a new window:
Copy: Select source files
5. Type on the file you are interested in. This file
is marked in blue.
On the left of group, person, or folder there will be a [+] or [-] sign.
Type on [+] opens the file, type on [-] closes the file.
6. Tap on Copy and you can copy the file.
7. Tap on the folder where the file is to be inserted.
8. This folder, group or person is marked blue.
9. Type on Paste and the folder is copied.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
? Edit
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Edit
Cancel
? Copy: Select source files
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Copy
Cancel
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
11
2.4 File Delete
1. Tap on the menu strip Files.
2. There appears another menu strip with the
functions: New, Edit, Copy and Delete
3. Tap on Delete.
4. There appears a new window: Delete
5. Tap on the file you are interested in. This file will be marked blue.
On the left of group, person, or folder, there will be a [+] or [-] sign.
Tap on [+] opens the file, tap on [-] closes the file.
6. Tap on Delete. If the file is empty it will be deleted
immediately.
7. A warning window pops up when the file
is not empty. Tap on delete in the warning window.
8. Now the file is deleted definitely.
? Delete
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Delete
Cancel
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
12
3.1 Program New
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on New.
4. There appears another menu strip with the functions:
Directory, Program
5. Tap on Program.
6. There appears a new window: Edit program name
7. Tap on the alphabetic letters on the touch screen. The length of name consists of maximal 10
characters.
The first letter is automatically capitalized.
Capitalization and use of small letters can be regulated by the option fields ABC and
abc.
The numbers 0-9 can be put in using the numerical keyboard [see operating-elements
of the Labcycler (1)] or the option field special.
The option field special contains furthermore special characters: Dot, comma, plus,
minus, and so on.
8. Tap on Enter to confirm the name of the program.
Tapping on Cancel will terminate the process.
9. There appears a new window: Edit program
Parameters of the lid can now be put in
Under Header and Advanced:
Heated Lid: on/off
Preheating: on/off
Comment: max. 30 characters
Temperature: 5.0 C to 98 C
Pressure*: 30 to 120 Newton
Fast block Control**: on/off
Block temperature preheating: 5.0 C to 99 C
Reaction tubes and recommended pressures (not Labcycler 48):
Thin wall single tubes: 30-60 Newton
Thick wall single tubes: 30-90 Newton
96-well plates: 90-120 Newton
384-well plates: 100-120 Newton
*Only Labcycler Basic and Gradient are adjustable, not Labcyler 48
**Activated Fast block Control has a maximum of acceleration coming to the heating and cooling rate, which are
adjusted. Deactivated Fast block Control decrease the acceleration. This could be an advantage for PCR processes
with low heating rates, e.g. multiplex PCR.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
Directory
Program
Block temperature preheating 25.0
Name
Heated Lid
Preheating
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
Demonstration 1
Temperature [C]
Pressure [N] 30.0
96.0
Schnelle Blockregelung
13
The pressure can be increased if more reaction tubes are in use. A uniform allocation supports
the dispersion of the pressure. Empty reaction tubes in the corners of the block are
recommended but are not essential.
10. Tap on Steps to put in the program steps.
11. There appears a new window. Tap on the input field
to activate it:
Temp [C] = Temperature -5.0 C to 99 C
Time = Period of the Step; the input occurs in
seconds. Data > 60 seconds are automatically
calculated in minutes. One dot behind the
number is used for minutes, 2 dots are used for hours.
Zero [0] is used for endless []. Use the dot function at the display.
= Return step is the step to which the program returns after execution of actual step.
The entered number must not be larger than the number of the actual step.
# Passes = Valid range min. 1, max. 99. 1 means that no return will be executed. The
value can only be changed, if a return step is entered in the neighbouring field.
The both scroll bars can be moved by tapping on them.
If the lower scroll bar moves to the right of the window, it shows the functions
gradient (Grad), ramp rates (Ramp), temperature (de)increments (dT), and
time(de)increments (dt).
13. If there is no need for using Grad, Ramp, dT, or dt tap on Save.
14. There appears a new window: Select target directory.
15. Type on the file you are interested in. This file is marked blue.
On the left side next to group, person, or folder a there is a [+] or [-] sign.
Type on [+] opens the file, type on [-] closes the file.
16. Tap on Save.
17. There appears a new window: Edit program. Tap on Close.
18. There appears the window Block Monitor, and you can put in new data or start a program.
Temp
[ C]
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
Time
h:mm:ss
#
Passes
Grad
+- [C]
1
2
3
14
3.1.1 Temperature Gradients
Only the Labcycler Gradient, Labcycler 48 Gradient, and Labcycler 48s Gradient have a gradient
function, not the Labcycler Basic, and Labcycler 48.
Labcyler Gradient: The Thermoblocks 48, 96, and 384 are gradient capable. The Gradient can be
maximal 40 C ( 20 C around the middle value).
Labcycler 48 (48s) gradient: The Gradient can be maximal 20 C ( 10 C around the middle value).
If the gradient function is in use the maximal temperature is shown in green, the middle in yellow, and
the minimal in red. The minimal value is in the extreme left column, the maximal value in the extreme
right.
The window Edit program must be open.
This window is open when you are working on
a new or old program.
1. Tap on column Grad +/-[C] (grey column) in
which the gradient shall be put in.
2. There appears a new window: Gradient Step
3. Put in the value of the gradient in the field at the
left upper corner and tap on Enter.
4. The Labcycler calculates automatically the temperatures and shows which temperature is in
which column. The extreme left column has the minimal value and the extreme right the
maximal value.
5. Tap on Close.
6. Edit program appears.
7. Tap on Save.
8. Tap on Close.
9. Block Monitor appears, and you can put in new data or start a program.
Temp
[ C]
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
Time
h:mm:ss
#
Passes
Grad
+- [C]
1
2
3
15
3.1.2 Heating and Cooling Temperature: Ramp
All Labcycler versions have the possibility to regulate the heating and cooling rate: Ramping.
Labcycler Basic and Gradient: Maximal heating rate of Thermoblock 48, 96, and 384 is 4.2 C/s,
maximal cooling rate is 3.6 C/s. The Triple Block has 2.5 C/s heating and 2.2 C/s cooling rate.
Labcycler 48, 48 Gradient ands 48s Gradient: Maximal heating rate of Labcycler 48 and 48
Gradient is 3.5 C/s and Cooling rate 3.2 C. Labcycler 48s Gradient allows heating and cooling
rates in excess of 5 C.
It is possible to put in a maximal value of 5.0 C degrees. If the value which is add on is higher
than maximal heating and cooling rates the Labcycler will operate with maximum speed.
Minimal heating and cooling rates are 0.001 C degrees.
If no value is added, the device operates with maximal heating and cooling rates.
The window Edit program must be open.
This window is open when you are working on
a new or old program.
1. Move the lower scroll bar to the right.
2. Tap on column Ramp [C/s] (grey column) in
which the heating or cooling temperature
shall be put in.
3. Values from 0.001 to 5.0 are possible.
If the value is out of the range an error
window will pop up. Tap on OK.
4. Put in the new value and type Enter.
5. Tap on save or put in other program data.
10. Tap on Save.
11. Tap on Close.
12. There appears the window Block Monitor, and you can put in new data or start a program.
Error
Value out of range!
Valid range is: 0.001-5.000
OK
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
#
Passes
Grad
+- [C]
1
2
3
Ramp
[C/s]
dT
[C]
dt
[s]
16
3.1.3 Temperature In(de)crements [dT]
All Labcyclers have these functions.
Temperature in(de)crements are in the range of 9.99 C to + 9.99 C degrees.
Negative data operate a decrement, positive an increment.
Increments over the temperatures of 99 C degrees are automatically stopped at this point.
Usually temperature decrements are used to reduce the unspecific binding of primers during the
first cycles of annealing steps.
The window Edit program must be open.
This window is open if you put in a new program
or if you work with an old program.
1. Move the lower scroll bar to the right.
2. Tap on column dT [C] (grey column) in
which the time shall be put in.
3. Values from 9.99 C to + 9.99 C degrees
are possible.
If the value is out of the range an error
window will pop up. Tap on OK.
4. Put in the new value and type Enter.
5. Tap on Save.
6. Tap on Close.
7. There appears the window Block Monitor appears, and you can put in new data or start a
program.
Error
Value out of range!
Valid range is: -9.99 - 9.99
OK
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
#
Passes
Grad
+- [C]
1
2
3
Ramp
[C/s]
dT
[C]
dt
[s]
17
3.1.4 Time In(de)crements [dt]
All Labcycler have these functions.
Time in(de)crements are in the range of 99.99 C to + 99.99 seconds.
Negative data operate a decrement, positive an increment.
Time increments are often used to compensate decreasing activity of polymerase during PCR
process.
The window Edit program must be open.
This window is open if you put in a new program
or if you work with an old program.
1. Move the lower scroll bar to the right.
2. Tap on column dt [s] (grey column) in
which the time shall be put in.
3. Values from 99.99 C to + 99.99 seconds
are possible.
If the value is out of the range an error
window will pop up. Tap on OK.
4. Put in the new value and type Enter.
5. Tap on Save.
6. Tap on Close.
7. Block Monitor appears and you can put in new data or start a program.
Error
Value out of range!
Valid range is: -99.99 - 99.99
OK
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
#
Passes
Grad
+- [C]
1
2
3
Ramp
[C/s]
dT
[C]
dt
[s]
18
3.2 Program Edit
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on Edit.
4. There appears a new window: Edit program
5. Tap on the program you are interested in. This
program is marked blue.
On the left next to group, person, or folder there is a [+] or [-] sign.
Type on [+] opens the file, type on [-] closes the file.
6. Tap on Edit and you can put in the information.
For furthermore information possibilities
see Program New.
7. Tap on Save.
8. Tap on Close.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
? Edit
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Edit
Close
19
3.3 Program Copy
Two Labcycler can be connected with a RS232 cable. All files will appear in green letters. Only the
files in green letters can be copied to the device of origin.
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on Copy.
4. There appears a new window:
Copy: Select source files
5. Tap on the program you are interested in. This
program is marked blue.
On the left next to group, person, or folder there is a [+] or [-] sign.
Type on [+] opens the file, type on [-] closes the file.
6. Tap on Copy.
7. Tap on the folder, the person or the group in which
the copied program should be placed.
8. This folder, person, or group is marked blue.
9. Tap on Paste.
3.4 Program Delete
1. Tap on the menu strip Files.
2. There appears another menu strip with the functions:
New, Edit, Copy and Delete
3. Tap on Delete.
4. There appears a new window: Delete
5. Tap on the program you are interested in. This
program is marked blue.
On the left , next to group,
person, or folder there is a [+] or [-] sign.
Type on [+] opens the file,
type on [-] closes the file.
6. Tap on Delete.
7. Tap on Close.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
? Delete
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Delete
Close
? Copy: Select source files
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Copy
Close
20
3.5 Program Start
Please, pay attention and put the tubes uniformly into the block. We advise to put empty tubes in the
corners of each Thermoblock system.
If you work with the Triple Block you can start each sub-block at different points of times. You can
open the device while other sub-blocks are running, but the active lid should not be longer open than 3
minutes. During the opening the passive lids store the heat and inhibit the condensing effects in the
cap. It is necessary to wear protective gloves against heat while the lid is open.
1. Tap on menu strip Run.
While working with the Triple Block it appears
a menu bar concerning the choice of block.
Choose block 1, 2, or 3. The activated block
will be marked in white.
2. There appears another menu strip with the
functions: Start, Stop now, Pause, Continue,
and Reports.
Triple Block: The protocol function is at
the menu bar blocks.
3. Tap on Start.
4. There appears a new window: Start.
5. Type on the program you are interested in. This
program is marked blue.
On the left, next to group,
person, or folder there is a [+] or [-] sign.
Type on [+] opens the file, type
on [-] closes the file.
The button Start now shows a green light.
6. Tap on Start now. The electric lid is moving down.
A warning window appears.
7. The program is starting.
The upper area of the touch screen shows the rest of running time.
Tap on Step Listing and you can see which step is just active.
Tap on Graphic and you can see the temperature profile.
Tap on Info and you are getting general information.
? Start
Files Run Options Help
X
Cycler
Group
+
Person 1
Person 2
Folder 1
PCR Program
Show
Start now
Close
? Block Monitor Date
Files Run Options Hel p
Start
Stop now
Pause
Continue
Reports
21
3.6 Program Stop
If you work with the Triple Block you can stop each sub-block at different points of times. You can
open the device while other sub-blocks are running, but the lid should not be longer open than 3
minutes. During the opening the passive lids store the heat and inhibit the condensing effects in the
cap. It is necessary to wear protective gloves against heat.
1. Tap on menu strip Run.
2. There appears another menu strip with the
functions: Start, Stop now, Pause, Continue,
and Reports.
3. Tap on Stop now.
4. The program stops and the electric lid moves up.
? Block Monitor Date
Files Run Options Hel p
Start
Stop now
Pause
Continue
Reports
22
3.7 Program Pause (manual)
You can interrupt a process at any time by using the key
Pause.
1. A program is still running.
If you work with the Triple Block you
must choose the block by tapping
on the menu bar.
2. Tap on menu strip Run.
3. There appears another menu strip with the
Functions: Start, Stop now, Pause,
and Reports.
4. Tap on Pause.
5. The lid moves up. A warning window appears.
The temperature is constant at that step where the PCR process is.
6. Tap on Run and type Continue.
7. The pause is finished, and the lid moves down. The program goes on.
3.8 Program Pause (hard coded)
1. You will get a hard coded pause if you put in
a zero (0) in the column time.
2. The sign appears signifying infinity.
3. If the program accomplishes this step the lid
moves up.
4. The temperature remains steady.
5. Tap on Run and Continue and the pause is finished.
6. The lid moves down and the program goes on.
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid-temperature
Block
Start
Stop now
Pause
Continue
Reports
96.0
93.0
55.0
Temp
[ C]
? Edit program
Files Run Options Help
Header Steps Info Advanced
Save
Close
Time
h:mm:ss
#
Passes
Grad
+- [C]
1
2
3
? Block Monitor Date
Files Run Options Help
Start
Stop now
Pause
Continue
Reports
23
3.9 Program Continue after power failure (Re-Start)
If a power failure appears during a program expiry or the device in the main switch is switched off, the
program will automatically continue, as soon as the power is switched on.
1. The block will immediately re-start.
2. It appears an Info-window.
3. Tap on OK.
4. The program is still running.
It is possible that unspecific agglomerations are generated during the temperature has decreased. To
reduce this problem the Labcycler starts automatically with the highest temperature of the last loop
(denaturing step). If the power failure has interrupted a normal step and not a loop, the Re-start goes
on at this step.
If the interruption stops longer than four days, a continuation will be renounced.
3.10 Program Reports
1. Tap on Run.
2. Tap on Reports. You will see a new window with the last program runs. The last program is
marked blue.
3. Tap on the program you are interested in. This program will be marked blue.
4. Tap on Show. A window appears and will show the information concerning the program of
interest.
5. Tap on Close. The window Reports is closed.
3.11 Online Monitoring
You can monitor the graphic while the PCR process is running. The rest of run time is shown to
you. Step-list is showing the step which is active. How long this step is active is also shown in the
screen window. If the gradient function is in use the maximal temperature is shown in green, the
middle in yellow, and the minimal is in red. The Info is showing other features like day and time
of starting and unexpected events.
Triple Block: The overview shows all three sub-blocks. It is possible to see all graphics at the
same time. The graphic of the left block is shown in red, of the middle block in yellow, and of the
right block in green. Nevertheless it is possible to see only one graphic or information concerning
one block if you tap on Block 1, Block 2, or Block 3.
Info
Power failure!
Programm is restarted!
For more details:
While running see Info.
After run see Reports.
OK
24
4.1 Block Removal (only Labcycler Basic and Gradient)
To Remove the Block
1. Switch off the device.
The Labcycler is not damaged when the block is taken off during power on. After
insertion the new block the device makes an analytic self test.
2. Open the device completely with the lid-unbolting-key [see operating elements (3)].
3. Seize the grip at the middle of the unbolting-handle (4) and move it vertically upwards.
The block is disconnected during this operation.
4. Move the block vertically out of the lifting hole.
Do not put anything at the top of the block.
Do not put anything in the lifting hole.
Do not start a program.
Do not grip into the ventilators.
To Insert the Block
1. Switch off the device.
2. Hold the block at the unbolting-handle [see operating elements (4)] so that the metal rail is in
the direction of the touch screen.
The block was constructed in a way that an incorrect insertion is not possible.
3. Insert the block vertically into the lifting hole.
5. If the connectors contact their counterpart move the lid-unbolting-key carefully down. Block
and device are connected after this process is finished.
6. Apply power.
7. The device makes an analytic self test.
8. The device is ready for use.
25
4.2 Heated Lid
Active Lid while thermoblock 48, 96 und 384 are in use.
The heated lid is automatically controlled by the program in use (see program new).
The heated lid is deactivated automatically if the difference of temperature between the lid and the
block is 75 C. The lid can be moved up (only Labcycler Basic and Gradient) whilst running a
program when a pause is set (see program pause by hand or programmed).
The heated lid can be moved without running a program:
1. Tap on Options. There appears a new menu bar.
2. Tap on Diagnosis.
3. Tap on Lid down.
The movement of the lid can be stopped by typing Lid stop or Lid up.
4. Tap on Lid up and the lid is moving up.
Active and passive lids while the Triple Block is in use.
It is necessary to work with three passive lids if the Triple Block is in use! It is necessary to wear
safety gloves against heat while working with the Triple Block and the passive lids. The passive lids
conduct the heat from the active lid to the caps. Therefore while the device is open they inhibit the
condensing effect.
The device can be opened to put probes inside, or to take out some probes. The head capacities of the
passive lids inhibit the condensing effects optimal for 3 minutes. After this time the lids are cooling
slowly down. Therefore condensing effects are increasing proportional to the opening time. Fast
working while the PCR processes are running is necessary!
The active lid will be deactivated if the temperature difference between the last active sub-block and
the lid is more than 75 C.
Auto mechanic Lid while Labcycler 48 is in use
The lid of Labcycler 48 is mechanically fixed and can be opened while a PCR process is still running.
4.3 Opening of the Labcycler in Case of an Emergency
This is only valid for Thermoblock 48, 96, and 384. The device can be opened in the extreme
emergency when the lid is driven down.
1. Check, whether there is an emergency or not. Is there any other possibility to move the electric
lid up (see heated lid)?
2. If there is no alternative possible, use the lid-unbolting-key [see operating-elements of
Labcyclers (3)]. Press down the lid with the other hand to relieve the bolts.
3. Open the device slowly!
While opening the heated lid or the sealing frame can touch the reaction tubes.
4. Check after the opening whether the lid is electronic controllable or not (see heated lid).
5. If the heated lid is not movable please contact SensoQuest or an authorized distributor.
26
4.4 Cleaning
Cleaning of the touch screen
Fingerprints can be removed by cleaning with a humid soft cloth (water or 70% ethanol). Do not use
cleaning agents with ammonia or abrasive. Do not clean with solutions because this can flow behind
the touch screen.
Use a humid soft cloth.
Glass cleaner without ammonia can be used.
To avoid fingerprints a touch pen can be used.
70% ethanol can be used for cleaning and disinfection.
Cleaning of the device and the block
Pull the net plug before starting purification. The lid and silver block must be allowed to cool
down. No liquids must enter inside the device.
Clean with a humid soft cloth. Use soft cleaning agents, water or 70% ethanol and no
aggressive substances or abrasive. Especially avoid scratching of the block and the surface of
the heated lid and the touch screen.
Occasionally clean the ventilation grille with vacuum cleaner.
Take the block out of the machine before cleaning. The block can be cleaned with a very low
humid cloth. Avoid liquids entering the block.
The wells can be purified with cotton buds.
27
4.5 Reaction Tubes and Compatibility
The Thermoblocks 48, 96, and 384 are compatible to the most standard test tubes and microtiterplates. If one
block is in use it is necessary to work with the same tubes. This is especially important for the three sub-blocks
of the Triple Block. We recommend flat cap tubes, especially when the Triple Block is used. All blocks should
be loaded symmetrically. It is necessary to put empty tubes in the corners of the blocks or sub-blocks (e.g. Triple
Block). We recommend the following tubes for Triple Block application: 72.737.002, Multiply-Pro, 0. 2 ml. If
stripes are used one tube must cut off at one side and the overhang must be cut off at the other side. Pay attention
that the passive lids are in the right position!
Compatibility 48 well block, 0.5 single tubes
Abgene AB-0350
Bio-Budget Technologies GmbH my-Budget PCR-Tubes 0.5 ml, cat. no. 20-3-110-50-0
Greiner bio-one Cat. No. 682201
Kisker Biotech G-005 (serial)
Compatibility 96 well block, 0.2 single tubes
Abgene AB-0620
Bio-Budget Technologies my-Budget PCR-Tubes 0.2 ml, cat. no. 20-3-010-50-0
Greiner bio-one Cat. No. 683201
Kisker Biotech G-001 (serial)
Compatibility 96 well block, stripes
Abgene AB-0266, AB-0624, AB-0648, AB-0866, AB-1183
Bio-Budget Technologies my-Budget 8er-Strips, cat. No. 30-SP-0020
Greiner bio-one Cat. No. 673210
Kisker Biotech G-002 (serial)
Compatibility 96 well block, plates
Abgene AB-0600, AB-0700, AB-0731, AB-0800, AB-900, AB-990, AB-1100, AB-
1300, AB-1400, AB-1500, AB-1900 AB-2800
Bio-Budget Technologies
my-Budget "96 well" PCR-plates, cat. no. 30-SP-9600
my-Budget "96 well" PCR-plates, (Skirted), 30-SP-0037
my-Budget "96 well" PCR-plates, (Semi-Skirted), 30-SP-0127
my-Budget "96 well" PCR-plates, (Low Profile), 30-SP-0029
Greiner bio-one Cat. No. 651501, 651550, 651560, 651570, 651585, 652201, 652270
Kisker Biotech G-060 (serial)
Sorenson Semi-Skirt 96 PCR plate , Skirted 96 PCR plate, 96-well ultra plate
Compatibility 384 well block, microtiterplates
Abgene AB-0937, AB-1111, AB-1384, TF-0384
Sealing Foil 0558
Bio-Budget Technologies My-Budget 384 well PCR-plates, 30-SP-0448
Greiner bio-one 785201, 785290
Kisker Biotech G-034
Sorenson 384-well PCR plate NX
28
4.6 Safety Instructions
The Labcycler may only be used for the intended purpose as detailed in the instruction manual,
after familiarisation with it.
Use the Labcycler only in closed rooms with normal air humidity. Let no liquids inside the
device.
No objects should be left inside the device because these can get into contact with electrically
loaded parts or block movable sections.
Do never touch hot parts of the Labcycler, especially the heating surface at the lid or the silver
block.
Do not touch mobile parts like the heating lid or the ventilation.
The Labcycler contains parts which are under high voltage. Attention! The instrument
contains high- voltage capacitors which can still be charged to dangerous voltage even a long
time after unplugging. Only trained expert persons may open the device.
Defect devices must be sent to the manufacturer or a service company which is licensed by
SensoQuest.
Chemical, radioactive or biologic contaminated devices may not be sent to the manufacturer.
4.7 Warranty
Providing the Labcycler has been used correctly, if within a period of two years from the date of
purchase of SensoQuest or an authorised SensoQuest specialist supplier, this product is deemed faulty,
it will be repaired or replaced according to judgement by SensoQuest. The warranty is not valid in the
following cases in which the customer is responsible to pay for the repair costs even if the faults occur
within the warranty period.
Any fault which is caused by improper operation.
Any fault which is caused by unprofessional repair, improper use, or incorrect cleaning.
Any fault which is cause by poor transport, dropping, or improper storage after buying the
product.
Any fault, which is caused by fire, earthquake, flooding, lightning, or other natural disaster.
The whole responsibility of SensoQuest is restricted to repair or displacement of the Labcycler.
Every liability for indirect or secondary damages of every kind which have originated to the
customer or which he has suffered on reasons of a lack of the product is excluded.
29
4.8 Technical Data
Device Labcycler Basic & Gradient Labcycler 48, 48s, Gradient
Line voltage 85 V to 265 V without switching, 50 to 60 Hz 200 V to 265 V without switching, 50 to 60 Hz
Power
consumption
Maximum 350 W, standby 25 W
Maximum 180 W, standby 25 W
Noise Idle 38 dBA, typical 44 dBA, maximum 48 dBA
Interfaces RS232
Heated lid
Electrically moving, temperature and pressure
programmable
Automatic
Lid pressure Programmable from 30 to 120 Newton Automatic, not programmable
Dimension
Length = 44 cm, width = 25 cm,
height = 20 cm
Length = 37 cm, width = 20 cm,
height = 16 cm
Weight 11,5 kg 7,8 kg
Display
TFT illuminated colour display VGA,
5.7 diagonal, 320 x 240 = 76800 Pixel,
touchscreen
TFT illuminated colour display VGA,
5.7 diagonal, 320 x 240 = 76800 Pixel,
touchscreen
Keyboard
Numeric silicone keys, virtual keys on the
touchscreen depending on the context
Virtual keys on the touchscreen depending on the
context
Languages English, German
Programs 680 5-step-programs, or at least 3000 steps
Protocol function The last 16 program runs can be displayed any time.
Password
protection
For 64 User
Temperature - 5.0 C to 99.0 C
Homogeneity 0.25 C at 55 C, 0.40 C at 95 C
Control accuracy 0.01 C/s
Ramp rate 0.001 C/s to 5.0 C/s
De(In)crements Temperature 9.99 C, time 99.99 seconds
Blocks
Electroformed gold plated silver, gradient
capable blocks: 40 C, 20 C from the left to
the right
Heating rate: 4.2 C/s, cooling rate 3.6 C/s
Thermoblock 48: 48-Well, 0.5 ml tubes, 8
zoning gradient
Thermoblock 96: 96-Well, 0.2 ml tubes, &
microplates, 12 zoning gradient
Thermoblock 384: 384-Well, 384 microplates,
24 zoning gradient
Triple Block 3x21: Aluminium
3 independent sub-blocks with 3 x 21 wells, 0.2
ml tubes, 3 passive Lids as condensing inhibitor,
3 different PCR processes at the same time, not
gradient possible
Heating rate: 2.5 C/s, cooling rate 2.2 C/s
Labcycler 48 & 48 Gradient:
Aluminium,
Thermoblock 48: 48-Well, 0.2 ml tubes, 8 zones
Gradient capable, 20 C, 10 C from the left to
the right
Heating rate: 3.6 C/s, cooling rate 3.1 C/s
Labcycler 48s Gradient:
Electroformed gold plated silver, gradient capable
Thermoblock 48: 48-Well, 0.2 ml tubes, 8 zones
Gradient capable: 20 C, 10 C from the left to
the right
Heating rate: ~5.0 C/s, cooling rate ~5.0 C/s
30
5.1 General User Management
Every Labcyler has the option to work with a user management. New devices have an inactive
user management. All data, programs and folder can be used by anyone.
The user management is used to contain access for specific person. Folders, groups and
persons can be saved with a password protection that only specific persons can see or use
them.
The first registered user is defined as main administrator with all rights and cannot be deleted.
The administrator or with short patterns Main Admin gives any user specific rights. Only
programs which are saved in a folder, person, or group can be protected. All other programs
are any time for anyone useable.
Up to 63 users with or without administrative rights can be stored. Users can be allocated to
working groups.
5.2 Set Up User Management
1. Tap on the menu strip of Options.
2. There appears another menu strip with
Settings, Remote Log in, Remote Log out
and Diagnosis.
3. Tap on Settings.
4. There appears a new window.
Tap on Users.
5. There appears a new window: Tap on
Configure User Management.
The User Management allows saving data. Folders can be saved for unwished access. The
administrator has the right to administrate the user list.
6. Tap on Continue.
7. Add your password at New Password
And Retype it. The password can contain
8 letters.
8. Tap on Enter.
9. Tap on Close.
The User Management is active and the administrator is registered. You are at the same time
logged in as administrator, and you can set up furthermore configuration.
Important: Please, write down the administrator password and save it. You cannot
make important changes in the use management without any knowledge of the password.
In urgent cases stay in contact with your vendor.
- - -
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
- - -
Name Main Admin
? Enter password
Files Run Otions Help
Enter
Cancel
Old Password
New Password
Retype
31
5.3 Administrator Log In & Log Out
The administrator has access of the whole directory. He has the right to set up new passwords and to
allocate rights.
Log In
1. Tap on Log In at the right upper corner
of the screen.
2. It appears a new window. Main Admin has
a blue background. This is the administrator.
The scroll arrow allows other
users the Log In.
3. Tap on the field password.
There appears a new window:
Enter password.
4. Put in your password. You can use the
numeric keyboard and the touch screen.
5. Tap on Enter.
6. There appears a new window: Log In
7. Tap again on Enter.
8. It appears a new window: Log In was successfully.
Password forgotten?
In case of a forgotten administrator password it will be necessary to stay in contact with the
vendor of the Labcycler.
Log Out
1. Tap on Log Out at the right upper corner
of the screen.
2. It appears a new window: User Logged off.
The administrator can set up an automatic log out. Automatic log out is possible after following
minutes: 60, 30, 10, 3, or never. The automatic log out occurs while a program is running. The
program will not be stopped while the log out. Only the user or the administrator can stop a password
protected program run.
?
Date, time Log In
Files Run Options Help
Ready
Temp
Lid temperature
Block
New Cycler
User:
? Log In
Files Run Options Help
Enter Cancel
User Main Admin
Password
32
5.4 Changing Administrator Password
The logged in administrator can chance the password.
1. Tap on the menu strip of Options.
2. There appears another menu strip with
Settings, Remote Log in, Remote Log out
and Diagnosis.
3. Tap on Settings.
4. There appears a new window.
Tap on Users.
5. There appears a new window. Tap on
Change own Password.
6. Put in the new password.
7. Tap on Retype and put in the new password
again.
8. Tap on Enter and then Save.
9. Tap on Close.
After logging out you can only log in with the new password.
5.5 Changing Administrator Properties
The administrator can later change following pattern: Name, automatic Log Out and password.
It is not possible to deactivate the main administrator rights. But it is possible to set down a user from
administrator to a standard user. These will reduce the rights of the user, and maybe its rights to get
access of password protected data.
Main Adninistrator
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
Main Admin
Name Main Admin
? Enter password
Files Run Otions Help
Enter
Cancel
Old Password
New Password
Retype
33
5.6 Deletion of User Management
User data can be deleted by logged in administrator. The deletion of the complete user management
resulted in the deletion of all user authorization. The complete directory is conserved. All programs
are usable for everyone after deactivation. If a new user administration is wished a new administrator
must be accessed.
1. Tap on Options at the menu bar.
1. There appears another menu strip with
Settings, Remote Log in, Remote Log out
and diagnosis.
2. Tap on Settings.
3. There appears a new window.
Tap on Users.
5. There appears a new window. Tap on
Configure User Management.
6. Tap on Delete all User Data. All authorization
will deactivated after finishing this process.
Programs will no be password protected.
7. It appears a new window.
8. Put in the password of the administrator.
The user management is deleted and all programs can be used by anyone.
Main Adninistrator
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
Main Admin
Delete all User Data...
? User Management
Files Run Options Help
Add
User
Main Admin
Name
Status
Delete Properties Close
Main administartor
User
34
5.7 The User or the Standard User
Users are individuals who use the Labcycler. A user is set up by the administrator. Generally a user is registered
as Standard User. But the user can also get the same rights as an administrator has. Unregistered users can work
as well; they are members of the group EVERYONE'.
Registered users can log in with a password. Each user can be a member of three working groups. The passwords
can be changed from the administrator or from the user. The administrator can give the user following rights: a)
reading and starting b) changing and deleting c) changing rights.
5.8 User Set Up
1. Tap on Options at the menu bar.
2. There appears another menu strip with
Settings, Remote Log in, Remote Log out
and Diagnosis.
3. Tap on Settings.
4. There appears a new window.
Tap on Users.
5. There appears a new window. Tap on
Configure User Management.
6. There appears a new window. Users are
shown under Main Admin.
7. Tap on Add. There appears a new window.
You can select the type of user: Person or
group. Tap on Enter.
8. It appears a new window. Put in the name of
the new user. Tap on Enter.
9. Put in the new password. Retype the
password and tap on 2x with Enter.
10. It appears a new window. The user can get administrator rights, but it is recommended to
give only the administrator or a few users administrator rights. Automatic Log Out can set
up as followed: Never, 3 min, 10 min, 30 min, and 1 hour.
11. Tap on Save and Close.
Main Adninistrator
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
Main Admin
Delete all User Data...
? User Management
Files Run Options Help
Add
User
Main Admin
Name
Status
Delete Properties Close
Main administartor
User
35
5.9 User Log In & Log Out
Log In
1. Tap on Log In at the upper corner of the screen.
2. There appears a new window.
3. There appears Main Admin blue deposited.
4. Tap on the scroll arrow.
5. You can choose on of the user. Tap on the user.
6. Add in the user specific password. You can use
the numeric keyboard as well as the touch
screen keyboard. Tap on Enter.
7. There appears a new window: Log-In. Tap on
Enter.
8. It appears a new window for a short moment:
Login successful.
Log Out
1. Tap on Log Out at the upper corner of the screen.
2. There appears a new window User logged off.
3. Tap on OK.
Automatic log out is possible after following minutes: 3 min, 10 min, 30 min, 1 hour, or never. The
automatic log out occurs while a program is running. The program will not be stopped while the log
out. Only the user or the administrator can stop a password protected program run.
Programs are closed while automatic Log Out. Is there any open data which was not saved the window
is closed but hidden. Only the user or the administrator will see this file after logging in again. While
this open file is still open no other file will be opened. The automatic log out occurs while a program
is still running. Only the user or the administrator can stop the program run before it ends. Other users
cannot stop the program run.
? Log In
Files Run Options Help
Enter Cancel
User Main Admin
Password
? Log In
Files Run Options Help
Enter Cancel
User User name
Password
36
5.10 Changing User Properties
The administrator can change subsequently following user features: Name, standard- or administrator
status, automatic Log Out, password, and membership. The new standard user password can be set up
without knowing the old one. If the name of a person is changed the access rights will be in spite of
this constant. Each user name can be used once.
Please consider that the subsequently transformation of an administrator to a standard user possible
limited its rights.
If there is a group registered you can you can register persons to this membership. 3 memberships are
for each person possible.
5.11 User Deletion
Users are deleted by the administrator. The administrator must be logged in.
1. Tap on Options at the menu bar.
2. There appears another menu strip with
Settings, Remote Log In, Remote Log Out
and Diagnosis.
3. Tap on Settings.
4. There appears a new window.
Tap on Users.
5. There appears a new window. Tap on
Configure User Management.
6. Tap on the User which shell be deleted.
This user is blue deposited.
7. Tap on Delete and then Continue.
8. Tap on Close twice.
The user is deleted.
Main Adninistrator
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
Main Admin
37
5.12 User Password Changing
The administrator can change any password. If one use has forgotten the password, the administrator
can set up a new one without knowing the old one. The user can change only there own password.
1. Tap on Options at the menu bar.
2. There appears another menu strip with
Settings, Remote Log In, Remote Log Out
and Diagnosis.
3. Tap on Settings.
4. There appears a new window.
Tap on Users.
5. There appears a new window: Settings.
Tap on Change own Password.
6. There appears a new window: Enter password.
Put in your old and new password and retype it.
Tap on Enter.
7. Tap on Save and then on Close.
Main Adninistrator
Name
? Settings
Files Run Options Help
General Time Users
Registered User
Save
Close
Status
Chance own Password
Configure User Management
Main Admin
Name Main Admin
? Enter password
Files Run Otions Help
Enter
Cancel
Old Password
New Password
Retype
38
5.13 Protection of Data
Programs can be protected if they are saved in a directory.
Are the programs not put in a directory they are useable for EVERYONE. The directory (folder, person, and
group) can be protected for specific person. Requirement is the activation of the user management by an
administrator. The administrator has the right to allocate and combine rights for folder, persons, and groups.
Following rights are possible: a) Read & Start, b) Write & Delete c) Change Rights.
A logged in user can see the part of the directory with Read & Start Right. All there parts and folders of the
directory are invisible.
Protection of directories
1. Tap on the menu strip Files.
2. There appears another menu strip with
the functions: New, Edit, Copy and Delete
3. Tap on Edit.
4. There appears a new window with the
directory. The administrator can see all
folders.
5. Tap on the folder, person, or group. This will be blue underlined.
6. Tap on Edit.
7. There appears a new window:
Edit directory.
Tap on Rights.
8. When the account is not protected, you will see
that group of authorized users is EVERYONE.
anybody as the right to Read + Start, to Write +
Delete, and to Change Rights.
9. Tap on Delete. The authorized user EVERYONE
is deleted.
10. Tap on Add. There appears a window where the users are listed. Tap on one or more users.
The users are blue underlined. Tap on Enter.
11. There appears a new window. Taping on Change can combine the different rights. The
Read and Start rights persist in any cases.
12. Tap on Save and Close.
? Block Monitor Date
Files Run Options Help
New
Edit
Copy
Delete
Transfer settings to subdirectories
? Edit directory
Files Run Options Help
Header Properties Rights
Save
Close
Authorized Read + Write + Change
users Start Delete Rights
Person 1 v v v
Person 2 v v
Person 3 v v
Add Delete Change
39
5.14 Remote Log In & Data Transfer between 2 Labcyclers
Every user has the possibility to transfer data from one Labcycler to another independent on type of Labcycler.
Both devices must be connected with a RS232 cable offered from SensoQuest as Inter-System-Copy-Cable. The
directory of the other device is shown in green letters.
In case that no user management is installed all data or parts can copied without any limitation.
In case of installed user management only data which are visible for everyone can copied without any limitation.
Protected data can only transferred after the user makes a Remote Log In. However, while the remittance the
access rights will be lost. In case of the user management shell be saved a full data transfer can optional used.
Remote Log In & Copy of Data
1. Tap on menu strip Options.
2. There appears another menu strip with
the functions: Settings, Remote Log In,
Remote Log Out and Diagnosis.
3. Tap on Remote log In.
If the Remote Log In is deactivated, there will be not contact with the other Labcycler or another user
is logged in. If there is no user management at the other device installed the Remote Log In will not
necessary.
4. There appears a new window: Remote Login: Chose a user and put the specific password
in. Confirm twice with Enter.
5. There appears for a short moment a new window: Login successful! And at the other
Labcycler appears a new window with remote logged in user. Tap on OK
After the successful Remote Log In, the directory of the other Labcycler is shown in green letters. You can mark
the parts of the directory. These parts get a blue background. Tap on Copy, and chose the part through tapping of
your directory where this copied part should be put in. When the target directory is chosen tap on Paste. All
copied data must get a new password protection in cases of necessity. The structure of the user management is
not conserved. If there is any interest in the complete user management of the other device a full data transfer
must be done (see full data transfer).
Remote Log Out
1. Tap on menu strip Options.
2. There appears another menu strip with
the functions: Settings, Remote Log In,
Remote Log Out and Diagnosis.
3. Tap in Remote Log Out.
4. There appears a new window:
User logged off!
5. Tap on OK.
If the Remote Log In is deactivated, the Remote Log In was interrupted.
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
Settings
Remote Log In
Remote Log Out
Diagnosis
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
Settings
Remote Log In
Remote Log Out
Diagnosis
40
Full Data Transfer
The Full Data Transfer offers the possibility to transfer the complete directory inclusive the user management to
another Labcycler.
Important: The Full Data Transfer deletes all data and the directory of the target Labcycler. It is mainly used to
install new devices in case that old devices are present. Therefore customer need not install the programs running
on the old device.
First of all both the Labcyclers must be connected with a RS232 cable offered at SensoQuest as Inter-System-
Cop-Cable. Only the main administrator can start the Full Data Transfer, and the Main admin must be logged in
before starting this process.
1. Tap on menu strip Options.
2. There appears a new menu strip.
3. Tap on Diagnosis.
4. There appears a new window: Service portal.
Put in the service code 777. Confirm with Enter.
5. Tap on Copy.
6. Tap on Receive.
7. There appears a new window: Receive
Warning:
All data of this Labcycler will be overwritten by data transmission. Do you really wish to
switch on the receive state?
8. Confirm with Yes.
9. Repeat point 1 to 5 at the transmitter Labcycler.
10. Tap on Send and confirm.
The transmission starts!
? Block Monitor Date
Files Run Options Help
Ready
Temperature
Lid Temp
Block
New Cycler
Settings
Remote Log In
Remote Log Out
Diagnosis
41
6.1 Order information
Product Order number
Labcycler Gradient 011-101
Without block
Labcycler Basic 011-103
Without block
Inter System Copy Cable 011-702
Gradient- Up Grade 011-801
Thermoblock 384 012-101
For microtiterplates 384-well
Thermoblock 48 012-102
For reaction tubes of 0.5 ml
Thermoblock 96 012-103
For reaction tubes of 0.2 ml
and microtiterplates 96-well
Sealing pad for Thermoblock 384 012-701
Labcycler 48 013-101
Labcycler 48 Gradient 013-102
Labcyler 48s Gradient 013-104
42
7.1 Index
+- Column 3.1.1 Online Monitoring 3.5
? Key 1.1 & 1.8 Opening 1.2
- Key 1.9 Opening (case of emergency) 4.3
x Key 1.9 Options 1.6 & 1.7
- Symbol 2.2 Order Information 4.9
+ Symbol 2.2 Order Number 4.9
Administrator 5.3-5.5 Password 5.4 & 5.12
Article Number 4.9 Pause 3.7 & 3.8
Blocks 4.8 Power Consumption 4.8
Block Changing 4.1 Power Failure (Re-Start) 3.10
Capitalization 2.1 & 3.1 Power Supply 1.4
Cleaning 4.4 Program 3.1-3.10
Compatibility Tubes 4.5 Program Capacity 4.8
Cooling Rate 3.1.2 & 4.8 Program Edit 3.2
Copy File 2.2 Program New 3.1
Copy Program 3.3 Program Runs 3.1
Date Input 1.7 Program Steps 3.1
Delete File 2.4 Protocol 3.10
Delete Program 3.4 Purification 4.4
Delete Program Step 3.2 Reaction Tubes 4.5
Dimension 4.8 Return Step 3.1
Display 4.8 Run 3.5
Directory 2.1-2.4 Scope of Delivery 1.1
Directory Selected 2.1 Scope of Supply 1.1
Error Window 1.9 & 3.1 Scroll Bar 1.9
Fast Control 3.1 Seconds Input 3.1
Files 2.1-2.4 Self Test 1.5
File Edit 2.2 Set up 1.3
File New 2.1 Safety Instruction 4.6
Folder 2.1 Special Characters 2.1 & 3.1
Gradient 3.1.1 & 4.8 Start window 1.5 & 1.9
Guarantee 4.7 Start Program 3.5
Heated Lid 4.2 & 4.8 Stop Program 3.6
Heating Rate 3.1.2 & 4.8 Technical Data 4.8
Help 1.5 & 1.8 Temperature 4.8
Homogeneity 4.8 Temperature Input 3.1
Hours Input 3.1 Temperature Gradient 3.1.1
Initial Start up 1.5 Temperature In(de)crements 3.1.3
Insert Program 3.3 Temperature Run 3.5
Insert Program Step 3.2 TFT-Monitor 1.1 & 1.5
Interfaces 4.8 Touch-Field 1.5
Keyboard 1.2 & 4.8 Time Input (Local Time) 1.7
Language Set up 1.6 Time Input (Program) 3.1
Lid Control 4.2 Time In(de)crements 3.1.4
Lid-unbolting-key 1.2 & 4.1 Touch-Pen 1.5
Line Voltage 1.4 & 4.8 Touch Screen 1.5
Loops 3.1 User 5.7-5.12.
Loudness 4.8 User administration 5.1-5.2
Menu bar 1.5 Virtual Keys 4.8
Microtiterplates 4.5 Warranty 4.7
Minutes Input 3.1 Window Structure 1.9
Online-Help 1.8 Weight 4.8