Twido PLC Data Sheet
Twido PLC Data Sheet
Twido
05
Catalog
January
3
Contents Twido programmable controller
n New
New, extended functions are offered with Twido programmable controllers versions u 3.0 and with version 3.0 of TwidoSoft software:
n Incorporation of the new CANopen bus master module TWD NCO1M in the Twido programmable controller range allows the Twido master
to manage up to 16 slaves (motor starters, variable speed drives, etc.) connected to the CANopen bus.
n Connection to the Ethernet network:
- an integrated RJ45 port (Modbus TCP protocol) is available on the new 40 I/O Twido compact base controller TWD LCAE 40DRF,
- a new TwidoPort 499 TWD 01100 interface module also allows all Twido programmable controllers, versions u 3.0, to be connected to Ethernet
via one of the serial ports on the controller.
n A new gateway VW3 A8114, using Bluetooth technology, allows wireless communication between a programming PC or a Pocket PC and
a Twido compact or modular programmable controller.
n Four new analog I/O expansion modules TWD AMI 4LT/8HT, TWD ARI 8HT and TWD AVO 2HT have been added to the Twido
programmable controller range.
n A new system of macros for managing the slaves connected on a Modbus network or a CANopen bus allows easier programming of
applications with TwidoSoft software version 3.0, by simplifying writing of the program and improving comprehension of the code.
n The new TwidoAdjust software package TWD SMD 100p V30M is a software tool dedicated to the management and animation of Twido
applications, using a Pocket PC.
Compact and modular base controllers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 4 and 5
b Compact base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 6 to 11
b Modular base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 12 to 17
I/O modules
Selection guide discrete I/O modules . . . . . . . . . . . . . . . . . . . . . . pages 18 to 21
b Discrete I/O modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 22 to 29
Selection guide analog I/O modules . . . . . . . . . . . . . . . . . . . . . pages 30 and 31
b Analog I/O modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 32 to 37
b Master module for installation system AS-Interface . . . . . . . . . . pages 38 and 39
Communication
b CANopen bus master module, TwidoPort interface module and
communication protocols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 40 to 47
Advantys, Telefast
Consumption
for all the outputs
At state 1 c 5 V mA 30
c 24 V mA 40
At state 0 c 5 V mA 5
Real-time clock cartridge (optional)
Precision s/
month
+ 30 at 25 C
Autonomy days Approximately 30 at 25 C with fully charged battery
Battery type Lithium battery, not interchangeable
Charging time h Approximately 10 to charge from 0...90 % of the full charge
Life years 10
Memory cartridge (optional)
Cartridge type TWD XCP MFK32 TWD XCP MFK64
Memory type EEPROM
Memory capacity Ko 32 64
Save/transfer program and internal words All modular
base controllers
Base controllers
TWD LMDA 20DRT/40DpK
Program size increase 6000 instructions with base controllers
TWD LMDA 20DRT/40DpK
(1) Source output: positive logic, sink output: negative logic.
(2) 2A/a 240 V or 2A/c 30 V (with 1800 operations/hour max):
- electrical life: minimum 100 000 operations,
- mechanical life: minimum 20 x 10
6
operations.
16
References 0
Twido programmable controller 0
Modular base controllers
References
Sink/source inputs Outputs No. of I/O
expansion
modules
Program
memory
Reference Weight
kg
Modular base controllers, 20 I/O
12 c 24 V I 8 O, source transistor 4 3000 instructions TWDLMDA20DTK (2) 0.140
8 O, sink transistor 4 3000 instructions TWDLMDA20DUK 0.140
6 O, relay
2 O, source transistor
7 3000 instructions (1) TWDLMDA20DRT 0.185
Modular base controllers, 40 I/O
24 c 24 V I 16 O, source transistor 7 3000 instructions (1) TWDLMDA40DTK (2) 0.180
16 O, sink transistor 7 3000 instructions (1) TWDLMDA40DUK 0.180
Separate components
Description Application Type Reference Weight
kg
32 Kb memory cartridge For all base controllers
Application backup
Program transfer
EEPROM TWDXCPMFK32 0.005
64 Kb memory cartridge
(3)
For TWD LMDA 20DRT/40DpK
base controllers
Memory extension
Application backup
Program transfer
EEPROM TWDXCPMFK64 0.005
Real-time clock cartridge Date-stamping, RTC based programming TWDXCPRTC 0.005
Serial interface module See page 46 TWDNOZpppp
Digital display module See page 46 TWDXCPODM
Mounting kit
(Sold in packs of 5)
For fitting modular base controllers or
extensions on a mounting plate or panel
TWDXMT5
Replacement parts
Screw terminal blocks
(Sold in packs of 2)
Controller TWD LMDA 20DRT, 13 contacts TWDFTB2T13
Controller TWD LMDA 20DRT, 16 contacts TWDFTB2T16
Analog input cable For built-in analog input. Length 1 m TWDXCA2A10M
Pre-formed cables See page 58
Magelis compact displays
Description Protocol Compatible with
PLC types
Supply
voltage
Reference Weight
kg
Compact display, 2 lines of
20 characters
(alphanumeric display)
Uni-Telway,
Modbus
Twido, Nano, TSX Micro,
Premium
c 5 V by
terminal port
on PLC
XBTN200 0.360
Compact displays, 4 lines
of 20 characters
(matrix display)
Uni-Telway,
Modbus
Twido, Nano, TSX Micro,
Premium
c 5 V by
terminal port
on PLC
XBTN400 0.360
Twido (4), Nano, TSX Micro,
Premium, TSX series 7,
Momentum, Quantum
Other Modbus slave modules
c 24 V
external source
XBTN401 0.360
Display connection cable Uni-Telway,
Modbus
Twido, Nano, TSX Micro,
Premium
XBTZ978 0.180
Phaseo regulated switch mode power supplies
Description Input voltage
4763 Hz
Output
voltage
Rated
power
Rated
current
Auto-protect
reset
Reference Weight
V c V W A kg
Single-phase
regulated switch mode
power supplies (5)
a 100240
single-phase
wide range
c110220
(6)
24 15 0.6 Auto ABL7CEM24006 0.180
30 1.2 Auto ABL7CEM24012 0.220
a 100240
single-phase
wide range
24 48 2 Auto ABL7RE2402 0.520
72 3 Auto ABL7RE2403 0.520
120 5 Auto ABL7RE2405 1.000
Regulated switch mode
power supplies for the
AS-Interface cabling
system (7)
a 100240
single-phase
wide range
30 + 24 2 x 72 2.4 + 3 Auto ASIABLM3024 1.300
(1) 6000 instructions with memory extension cartridge TWD XCP MFK64
(2) Connection by HE 10 type connector, allowing use of the Telefast pre-wired system (see page 58).
(3) Memory extension with base controllers TWD LMDA 20DRT/40DpK.
(4) Connection via built-in port or via optional serial port on Twido programmable controllers.
(5) These products do not conform to standard EN 61000-3-2.
(6) Compatible input voltage, not indicated on the product.
(7) Without ground fault detection.
TWD LMDA
20DTK/20DUK
TWD LMDA
40DTK/40DUK
TWD LMDA 20DRT
TWD XCP MFK pp
XBT N401
ABL 7CEMpppp
ASI ABLM3024
17
Dimensions,
connections 0
Twido programmable controller 0
Modular base controllers
Dimensions
TWD LMDA 20DpK/20DRT/40DpK Installation rules
a b
TWD LMDA 20DTK/DUK 1.39" (35.4) 0 (excluding connector) Important:
b Horizontal or flat mounting not permissible.
b Avoid placing devices which generate heat (transformers, power supplies, power
contactors...) beneath the controller.
TWD LMDA 20DRT 1.87" (47.5) 14.6
TWD LMDA 40DTK/DUK 1.87" (47.5) 0 (excluding connector)
Connections
TWD LMDA 20DTK TWD LMDA 20DUK TWD LMDA 20DRT
v The COM (+) and COM (-) terminals are interconnected internally.
v The COM and COM (+), COM and COM (-) terminals are independent.
v The -V and +V terminals are interconnected internally.
v Output channels 0 and 1 are of the source transistor
type.
Output channels 2 to 7 are of the relay type.
v The COM terminals are independent.
TWD LMDA 40DTK TWD LMDA 40DUK
v Connectors CN1 and CN2 are independent.
v The COM (+) and COM (-) terminals are interconnected internally.
v The COM and COM (+), COM and COM (-) terminals are independent.
v The -V and +V terminals are interconnected internally.
(1) Supply connection for sink inputs (positive logic).
(2) Supply connection for source inputs (negative logic).
a
3.54"
(90 mm)
0.17"
(4.5 mm)
b
2.75" (70 mm)
0.78" (20 mm)
0.78" (20 mm)
3.14"
(80
mm)
3.14"
(80
mm)
0.78" (20 mm)
0.78" (20 mm)
3.14"
(80
mm)
Dual Dimensions
inches
(mm)
(1)
(2)
(2)
(1)
(1)
(2)
(1)
(2)
(1)
(2)
(2)
(1)
(2)
(1)
18
Selection guide 0
Twido programmable controller 0
Discrete I/O modules
Applications Discrete Input modules
Type 8 c 24 V inputs
(TWD DDI 8DT)
8 a 120 V inputs
(TWD DAI 8DT)
16 c 24 V inputs 32 c 24 V inputs
Connection By removable screw terminal block By HE 10 type connector
Allows use of the Telefast pre-wired system
Inputs Voltage ranges c 20.4...28.8 V (TWD DDI 8DT)
a 85...132 V (TWD DAI 8DT)
Input current 15 mA per point 7 mA per point 5 mA per point
Input logic Sink (1) Sink/source (1)
Commons 1 common point (TWD DDI 8DT)
2 common points (TWD DAI 8DT)
2 common points
Response time
v Energization 4 ms (TWD DDI 8DT), 25 ms (TWD DAI 8DT)
v De-energization 4 ms (TWD DDI 8DT), 30 ms (TWD DAI 8DT)
Outputs Output types
Voltage range
Commons
Output current
v Per output
v Per group of channels
Isolation Between channels: common point,
Between bus and channels: by photocoupler
I/O module type
TWD DpI 8DT TWD DDI 16DT TWD DDI 16DK TWD DDI 32DK
Page 24
(1) Sink input: positive logic, source input: negative logic.
19
0
0
Discrete mixed I/O modules Master module for AS-Interface cabling system
4 c 24 V inputs/4 relay outputs 16 c 24 V inputs/8 relay outputs b For controller versions 2.0
b Management of slave modules:
v Discrete: maximum of 62 slaves arranged in 2
banks, A/B, of 31 addresses each
v Analog: maximum of 7 slaves in bank A
b The AS-Interface M3 profile supports analog
profile 7.3 (7 slaves), but does not support
analog profile S-7.4
By removable screw terminal block By non-removable spring terminal block
c 20.4...28.8 V
7 mA per point
Sink/source
1 common point
4 ms
4 ms
1 N/O contact
a 240 V, c 30 V
1 common point 2 common points
2 A (Ith)
7 A (Ith)
Between input channels: common point, between output channels: common point
Between bus and channels: by photocoupler
TWD DMM 8DRT TWD DMM 24DRF TWD NOI 10M3
24 39
20
Selection guide (continued) 0
Twido programmable controller 0
Discrete I/O modules
Applications 8/16 output modules with removable screw terminal block
Type 8 c 24 V transistor outputs 8 relay outputs 16 relay outputs
Connection By removable screw terminal block
Inputs Voltage range
Input current
Input logic
Commons
Response time
v Energization
v De-energization
Outputs Output types Transistor Relay with 1 N/O contact
Voltage range c 20.4...28.8 V a 240 V, c 30 V
Logic (1) Sink Source
Commons 1 common point 2 common points
Output current
v Per output 0.3 A nominal 2 A max.
v Per group of channels 3 A at 28.8 V 7 A max. 8 A max.
Isolation Between channels: common point
Between bus and channels: by photocoupler.
Between channels: common point.
Between bus and channels: a 1500 V for
1 minute.
Output module type
TWD DDO 8UT TWD DDO 8TT TWD DRA 8RT TWD DRA 16RT
Page 24
(1) Source output: positive logic, sink output: negative logic.
21
0
0
16/32 output modules with HE 10 type connectors
16 c 24 V transistor outputs 16 c 24 V transistor outputs 32 c 24 V transistor outputs 32 c 24 V transistor outputs
By HE 10 type connector By HE 10 type connector
Allows use of the Telefast pre-wired
system
By HE 10 type connector By HE 10 type connector
Allows use of the Telefast pre-wired
system
Transistor
c 20.4...28.8 V
Sink Source Sink Source
1 common point 2 common points
0.1 A nominal
1 A at 28.8 V
Between channels: common point.
Between bus and channels: by photocoupler.
TWD DDO 16UK TWD DDO 16TK TWD DDO 32UK TWD DDO 32TK
24
22
Presentation,
description 0
Twido programmable controller 0
Discrete I/O modules
The range of Twido I/O modules includes input modules, output modules and mixed
input/output modules. With the 15 I/O modules offered, in addition to the I/O
integrated in 24 I/O compact base controllers and modular base controllers,
configurations can be adapted to best suit application requirements, so optimizing
costs. The following discrete I/O modules are available:
b 1 a 120 V discrete input module, 8 channels, fitted with a removable screw
terminal block
b 4 c 24 V discrete input modules comprising an 8-channel module, two 16-channel
modules and a 32-channel module, equipped with either removable screw terminal
blocks or HE 10 type connector, depending on the model. These modules can be
either sink or source.
b 8 discrete output modules comprising two output modules with 8 and 16 relay
outputs, three output modules with 8, 16 or 32-channel sink transistor outputs and
three output modules with 8, 16 or 32-channel source transistor outputs, equipped
with either removable screw terminal blocks or HE 10 type connector, depending on
the model
b 2 discrete mixed input and output modules, comprising one 4-channel input/
4-channel relay output module with removable screw terminal block and one
16-channel input/8-channel relay output module with non-removable spring terminal
block
The narrow width of these I/O modules (17.5 mm, 23.5 mm, 29.7 mm or 39.1 mm)
makes it possible to build Twido configurations of up to 264 I/O with a minimal overall
size of L 10.0 (255.4 mm) x H 3.54 (90 mm) x D 3.2 (81.3 mm).
All these discrete I/O modules and the analog I/O modules are connected to the base
controller by stacking them on a 5 rail, starting from the right-hand side panel of
the base controller, according to the following rules:
b For 24 I/O compact base controllers TWD LCpA 24DRF: 4 modules max. (see
characteristics page 6
b For 40 I/O compact base controllers TWD LCAp 40DRF: 7 modules max. (see
characteristics page 6)
b For 20 I/O modular base controllers TWD LMDA 20DpK: 4 modules max.
(see characteristics page 15)
b For 20 and 40 I/O base controllers TWD LMDA 20DRT/40DpK: 7 modules max.
(see characteristics page 15)
All the discrete I/O modules are electrically isolated with the use of a photocoupler
between the internal electronic circuit and the input/output channels.
Twido discrete I/O modules comprise:
1 An extension connector for electrical connection to the previous module (1)
2 One or two blocks for displaying the channels and module diagnostics
3 One or two connection components of varying type, depending on the model:
b removable screw terminal block (1 or 2) for modules whose reference ends in T
b HE 10 type connector (1 or 2) for modules whose reference ends in K
b non-removable spring terminal block for module TWD DMM 24DRF
4 Latching mechanism for attachment to the previous module
These modules are mounted on a symmetrical 5 rail. Mounting kit TWD XMT 5
(supplied in lots of 5) allows plate or panel mounting. For modules with removable
screw terminal block, the terminal blocks are supplied with the module.
(1) A connector on the right-hand side panel ensures continuity of the electrical link with the next
I/O module.
Presentation
Description
1
2
3
Module with
HE 10 type connector
Module with
removable screw
terminal block
4
23
Characteristics 0
Twido programmable controller 0
Discrete I/O modules
General characteristics
Temperature C Operation: 0+ 55. Storage: - 25+ 70.
Relative humidity 30 to 95%, without condensation
Degree of protection IP 20
Altitude m Operation: 02000. Storage: 03000.
Vibration resistance Mounted on 5 rail Hz 1057, amplitude 0.075 mm, acceleration 57150 Hz
m/s
2
9.8 (1 gn)
Plate or panel mounted (using
mounting kit TWD XMT 5)
Hz 225, amplitude 1.6 mm, acceleration 25100 Hz
m/s
2
39.2 (4 gn)
Shock resistance m/s
2
147 (15 gn) for 11 ms
Characteristics of c input channels
Module type TWD DAI 8DT DDI 8DT DDI 16DT DDI 16DK DDI 32DK DMM 8DRT DMM 24DRF
Number of input channels 8 8 16 16 32 4 16
Rated input voltage V a 120 V c 24 sink/source
Connection Removable screw terminal block HE 10 type connector Removable
screw
terminal
block
Spring
terminal
block
Commons 2 1 2 1
Input voltage range V a
85132
V
c 20.4...28.8
Rated input current mA 7.5 7 5 7
Input impedance k 11 3.4 4.4 3.4
Filter time At state 1 ms 25 8
At state 0 ms 30 8
Isolation No isolation between channels, isolation with internal logic by photocouplers
Internal consumption
for all inputs
At state 1 c 5 V mA 55 25 40 35 65 25 (1) 65 (1)
c 24 V mA 0 20 (1) 45 (1)
At state 0 c 5 V mA 25 5 10 5 (1) 10 (1)
Characteristics of transistor output modules
Module type TWD DDO 8UT DDO 8TT DDO 16UK DDO 16TK DDO 32UK DDO 32TK
Number of output channels 8 16 32
Output logic (2) Sink Source Sink Source Sink Source
Connection Removable screw terminal
block
HE 10 type connector
Commons 1 2
Nominal output values Voltage V 24
Current A 0.3 0.1
Output voltage range Voltage V 20.428.8
Current per channel A 0.36 0.12
Current per common A 3 1
Response time At state 1 s 300
At state 0 s 300
Residual voltage (voltage at state 1) V 1 max
Maximum inrush current A 1
Leakage current mA 0.1
Overvoltage protection V 39
Maximum power of filament lamp W 8
Isolation No isolation between channels, isolation with internal logic by photocouplers
Consumption
for all the outputs
At state 1 c 5 V mA 10 10 20
c 24 V mA 20 40 70
At state 0 c 5 V mA 5 5 10
Characteristics of relay output channels
Module type TWD DRA 8RT DRA 16RT DMM 8DRT DMM 24DRF
Number of output channels 8 N/O contacts 16 N/O contacts 4 N/O contacts 8 N/O contacts
Output currents Current per channel A 2
Current per common A 7 8 7
Minimum switching load mA 0.1/0.1 c V (reference value)
Contact resistance (when new) m 30 max
Loads (resistive, inductive) A 2A/a 240 V or 2A/c 30 V (with 1800 operations/hour max):
- electrical life: minimum 100 000 operations
- mechanical life: minimum 20 x 10
6
operations
rms insulation voltage V a1 500 for 1 minute
Consumption
for all the outputs
At state 1 c 5 V mA 30 45 See values above (input channels)
c 24 V mA 40 75 See values above (input channels)
At state 0 c 5 V mA 5 5 See values above (input channels)
(1) Consumption values are indicated for all inputs/outputs at state 0 or at state 1.
(2) Source output: positive logic, sink output: negative logic.
24
References
0
Twido programmable controller 0
Discrete I/O modules
These discrete I/O modules are mounted on symmetrical 5 rails to the right of the
Twido base controller. The maximum number of discrete and/or analog I/O modules
which may be mounted depends on the type of base controller:
References
Type of
TWD base
LCpA
10DRF
LCpA
16DRF
LCpA
24DRF
LCAp
40DRF
LMDA
20DpK
LMDA
20DRT
LMDA
40DpK
Number of
modules
0 0 4 7 4 7 7
TWD DDI 8DT TWD DDI 32DK
TWD DDO 16pK TWD DDO 8pT/DRA 8RT
TWD DRA 16RT
TWD DDO 32pK
TWD DDM 8DRT TWD DDM 24DRF
Discrete input modules
Input voltage No. of
channels
No. of
common
point
Connection Reference Weight
kg
c 24 V
sink/source
8 1 Removable
screw terminal
block (supplied)
TWDDDI8DT 0.085
16 1 Removable
screw terminal
block (supplied)
TWDDDI16DT 0.100
HE 10 type
connector
TWDDDI16DK (1) 0.065
32 2 HE 10 type
connector
TWDDDI32DK (1) 0.100
a 120 V 8 2 Removable
screw terminal
block (supplied)
TWDDAI8DT 0.081
Discrete output modules
Type of output No. of
channels
No. of
common
point
Connection Reference Weight
kg
Transistor
c24 V/0.3 A
8, sink 1 Removable
screw terminal
block (supplied)
TWDDDO8UT 0.085
8, source 1 Removable
screw terminal
block (supplied)
TWDDDO8TT 0.085
Transistor
c24 V/0.1 A
16, sink 1 HE 10 type
connector
TWDDDO16UK 0.070
16, source 1 HE 10 type
connector
TWDDDO16TK (1) 0.070
32, sink 2 HE 10 type
connector
TWDDDO32UK 0.105
32, source 2 HE 10 type
connector
TWDDDO32TK (1) 0.105
Relay 2 A (Ith)
a230 V/c30 V
8 (N/O
contact)
2 Removable
screw terminal
block (supplied)
TWDDRA8RT 0.110
16 (N/O
contact)
2 Removable
screw terminal
block (supplied)
TWDDRA16RT 0.145
Discrete mixed input/output modules
No. of
I/O
No. and
type of
inputs
No. and
type of
outputs
No. of
common
point
Connection Reference Weight
kg
8 4 I,
c24 V
sink/source
4 O, relay
(N/O
contact)
2 A (Ith)
Inputs:
1 common
Outputs:
1 common
Removable
screw terminal
block (supplied)
TWDDMM8DRT 0.095
24 16 I,
c24 V
sink/source
8 O, relay
(N/O
contact)
2 A (Ith)
Inputs:
1 common
Outputs:
2 commons
Non-removable
spring terminal
block
TWDDMM24DRF 0.140
(1) Module allowing use of the Telefast pre-wired system.
25
References (continued) 0
Twido programmable controller 0
Discrete I/O modules
(1) Cables strictly for applications other than use of Telefast sub-bases with Twido controllers.
For use of Telefast sub-bases with Twido controllers, see pages 50 to 63.
References
Separate components
Application Description Reference Weight
kg
Mounting kit For fitting discrete modules on a
mounting plate or panel
Sold in lots of 5
TWDXMT5
Telefast pre-wired system
for Twido
Connection sub-bases
I/O connection sub-bases
Pre-wired solutions
Cables and accessories
See page 59
HE 10 type connectors
Description Number
of ways
Reference Weight
kg
HE 10 female connectors
(sold in lots of 5)
20 TWDFCN5K20
26 TWDFCN5K26
Pre-formed cables for discrete I/O modules with HE 10 connectors
Description For use with
Twido
Gauge
C.s.a.
Cable
length
Reference Weight
kg
Pre-formed cables,
1 pre-formed cable:
one end with HE 10
connector, one end
with free wires
Modular base
controllers
TWD LMDA
20DTK/40DTK
22
0.035 mm
2
3 m TWDFCW30M 0.405
22
0.035 mm
2
5 m TWDFCW50M 0.670
I/O extensions
TWD DDI
16DK/32DK
TWD DDO
16pK/32pK
22
0.035 mm
2
3 m TWDFCW30K 0.405
22
0.035 mm
2
5 m TWDFCW50K 0.670
Connecting cables (1)
Description For use with
Twido
Gauge
C.s.a.
Cable
length
Reference Weight
kg
Discrete I/O
pre-formed cables,
1 pre-formed cable:
one end with 26-way
HE 10 connector on Twido
side, one end with two
20-way HE 10connectors
on Telefast side
Modular base
controllers
TWD LMDA
20DTK/40DTK
28
0.080 mm
2
1 m ABFTP26MP100 0.200
28
0.080 mm
2
2 m ABFTP26MP200 0.500
28
0.080 mm
2
3 m ABFTP26MP300 0.800
Discrete input
pre-formed cables,
1 pre-formed cable: one
end with 20-way HE 10
connector on Twido side,
one end with 20-way HE 10
connector on Telefast side
Inputs
TWD DDI
16DK/32DK
28
0.080 mm
2
1 m ABFTE20EP100 0.080
28
0.080 mm
2
2 m ABFTE20EP200 0.140
28
0.080 mm
2
3 m ABFTE20EP300 0.210
Discrete output
pre-formed cables
1 pre-formed cable: one
end with 20-way HE 10
connector on Twido side,
one end with 20-way HE 10
connector on Telefast side
Outputs
TWD DDO
16TK/32TK
28
0.080 mm
2
1 m ABFTE20SP100 0.080
28
0.080 mm
2
2 m ABFTE20SP200 0.140
28
0.080 mm
2
3 m ABFTE20SP300 0.210
26
Dimensions,
connections 0
Twido programmable controller 0
Discrete I/O modules
Dimensions
Discrete I/O modules
TWD a c
DDI 8DT/DAI 8DT 0.92 (23.5) 0.57 (14.6)
DDI 16DT 0.92 (23.5) 0.57 (14.6)
DDI 16DK 0.69 (17.6) 0.44 (11.3)
DDI 32DK 1.16 (29.7) 0.44 (11.3)
DDO 8UT/8TT 0.92 (23.5) 0.65 (16.6)
DDO 16UK/16TK 0.69 (17.6) 0.44 (11.3)
DDO 32UK/32TK 1.16 (29.7) 0.44 (11.3)
DRA 8RT/16RT 0.92 (23.5) 0.57 (14.6)
DMM 8DRT 0.92 (23.5) 0.57 (14.6)
DMM 24DRF 1.53 (39.1) 0.04 (1.0)
inch (mm)
Connections
ABF TP26MPp00 ABF TE20EPp00 ABF TE20SPp00
HE 10
26-way A
HE 10
20-way B
HE 10
20-way C
HE 10
26-way A
HE 10
20-way B
HE 10
26-way A
HE 10
20-way B
Twido side Input side Output side Twido side Input side Twido side Output side
1 18 1 1 18
2 20 2 2 20
3 20 3 18 3 19
4 12 4 20 4 17
5 17 5 16 5 16
6 11 6 8 6 8
7 19 7 15 7 15
8 10 8 7 8 7
9 9 14 9 14
10 9 10 6 10 6
11 8 11 13 11 13
12 8 12 5 12 5
13 7 13 12 13 12
14 7 14 4 14 4
15 6 15 11 15 11
16 6 16 3 16 3
17 5 17 10 17 10
18 5 18 2 18 2
19 4 19 9 19 9
20 4 20 1 20 1
21 3
22 3
23 2
24 2
25 1
26 1
c 2.75 (70 mm) a
0.17
(4.5 mm)
3.54
(90 mm)
27
Connections (continued) 0
Twido programmable controller 0
Discrete I/O modules
Connections (continued)
Input modules
TWD DDI 8DT (c 24 V) TWD DAI 8DT (a 120 V) TWD DDI 16DK (c 24 V)
v The COM terminals are linked internally v The COM terminals are linked internally
TWD DDI 16DT (c 24 V) TWD DDI 32DK (c 24 V)
v The COM terminals are linked internally v The COM0 terminals are linked internally.
v The COM1 terminals are linked internally.
(1) Source input (negative logic)
(2) Sink input (positive logic).
(1)
(2)
0 I0
I1
I2
I3
I4
I5
I6
I7
1
2
3
COM1
NC
4
5
7
6
COM0
a
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
28
Connections (continued) 0
Twido programmable controller 0
Discrete I/O modules
Transistor output modules
TWD DDO 8UT TWD DDO 8TT
TWD DDO 16UK TWD DDO 16TK
TWD DDO 32UK TWD DDO 32TK
Terminals:
v COM (-) are linked internally.
v COM0 (-) are linked internally.
v COM1 (-) are linked internally.
v + V are linked internally.
v + V0 are linked internally.
v + V1 are linked internally.
Terminals:
v COM (+) are linked internally.
v COM0 (+) are linked internally.
v COM1 (+) are linked internally.
v - V are linked internally.
v - V0 are linked internally.
v - V1 are linked internally.
Fu
Fu
Fu Fu
Fu Fu
Fu Fu
Fu Fu
Fu Fu
Fu Fu
29
Connections (continued) 0
Twido programmable controller 0
Discrete I/O modules
Relay output modules
TWD DRA 8RT TWD DRA 16RT
Terminals:
v COM0 are linked internally.
v COM1 are linked internally.
v COM0 and COM1 are independent
(1) Sink output (negative logic)
(2) Source output (positive logic)
Mixed input/output modules
TWD DMM 8DRT TWD DMM 24DRT
v The COM (+) terminals are linked internally v Terminals COM0, COM1 and COM2 are independent
v Terminals - V are linked internally.
(1) Source input (negative logic)
(2) Sink input (positive logic)
(3) Sink output (negative logic)
(4) Source output (positive logic)
(1) (2)
(1) (2)
Fu
(1) (2)
(1) (2)
Fu
(3) (4)
Fu
(1)
(2)
(3) (4)
(3) (4)
Fu
(1)
(2)
30
Selection guide 0
Twido programmable controller 0
Analog I/O modules
Applications Analog input modules
Number of I/O 2 inputs 4 inputs 8 inputs 8 inputs
Type Voltage/current Voltage/current
Temperature
Voltage/current PTC/NTC
Connection Removable screw terminal block
Inputs Range 0...10 V
(non differential)
4...20 mA
(differential)
0...10 V
(non differential)
0...20 mA
(differential)
Pt 100/1000
NI 100/1000
0...10 V
(non differential)
0...20 mA
(differential)
Resolution 10 bits (1024 points) 12 bits (4096 points) 10 bits (1024 points)
Acquisition period 32 ms + 1 controller
cycle time
160 ms
Outputs Range
Resolution
Transfer time
External supply c 24 V external power supply to sensors/pre-actuators (voltage range 20.428.8 V)
Isolation Isolation between channels and ground: by photocoupler
Analog I/O module type
TWD AMI 2HT TWD AMI 4LT TWD AMI 8HT TWD ARI 8HT
Pages 35
31
0
0
Analog output modules Analog mixed I/O modules Master module for
AS-Interface cabling system
1 output 2 outputs 2 inputs/1 output b For controller versions 2.0
b Management of slave
modules:
v Discrete: maximum of 62
slaves arranged in 2 banks,
A/B, of 31 addresses each
v Analog: maximum of 7 slaves
in bank A
b The AS-Interface M3 profile
supports analog profile 7.3 (7
slaves), but does not support
analog profile S-7.4.
Voltage/current Voltage Voltage/current Thermocouple/temperature
probe inputs
Voltage/current output
Removable screw terminal block
0...10 V (non differential)
4...20 mA (differential)
Thermocouple
type K, J and T
Pt100 3-wire temperature
probe
12 bits (4096 points)
32 ms + 1 controller cycle
time
100 ms + 1 controller cycle
time
0...10 V
4...20 mA
10 V 0...10 V
4...20 mA
12 bits (4096 points) 11 bits + sign (2048 points) 12 bits (4096 points)
20 ms + 1 controller cycle
time
0.3 ms + 1 controller cycle
time
20 ms + 1 controller cycle time
TWD AMO 1HT TWD AVO 2HT TWD AMM 3HT TWD ALM 3LT TWD NOI 10M3
35 39
32
Presentation,
description
Twido programmable controller 0
Analog I/O modules
Twido analog I/O expansion modules enable the acquisition of various analog values
encountered in industrial applications.
Analog output modules are used to control the pre-actuators in devices such as
variable speed drives, valves and applications that require process control. The
output current or voltage is proportional to the numerical value defined by the user
program. When the Twido controller stops, the outputs can be configured with
fallback (reset to the lowest scale value or hold the last value received). This function,
when set to 'hold', is useful when debugging the application or when a fault occurs,
in order not to disturb the process being controlled.
The 8 following analog I/O modules are available:
b One module with 2 inputs: 010 V, 420 mA
b One module with 4 inputs: 010 V, 020 mA, Pt 100/1000, Ni100/1000 range
122 ... 302 F (50...150 C)
b One module with 8 inputs: 010 V, 020 mA
b One module with 8 inputs: PTC/NTC
b One module with 1 output: 010 V, 420 mA
b One module with 2 outputs: 10 V
b One mixed module with 2 inputs: 010 V, 420 mA and 1 output: 010 V,
420 mA
b One mixed module with 2 thermocouple or temperature probe inputs and one
010 V, 420 mA output
Twido analog extension modules offer a resolution of 10 bits, 11 bits + sign and
12 bits, with connection by removable screw terminal block. An external c 24 V
power supply is required for each analog module.
Like discrete I/O modules, analog I/O modules are connected to the base controller
by stacking them on a 7 rail, starting from the right-hand side panel of the base
controller, according to the following rules:
b For 24 I/O compact base controllers TWD LCpA 24DRF: 4 modules max. (see
characteristics page 8)
b For 40 I/O compact base controllers TWD LCpA 40DRF: 7 modules max. (see
characteristics page 8)
b For 20 I/O modular base controllers TWD LMDA 20DpK: 4 modules max. (see
characteristics page 15)
b For 40 I/O modular base controllers TWD LMDA 20DRT/40DpK: 7 modules max.
(see characteristics page 15)
All analog I/O modules are electrically isolated with the use of a photocoupler
between the internal electronic circuit and the input/output channels
Twido analog I/O modules comprise:
1 An extension connector for electrical connection to the previous module (1)
2 A block for displaying the channel and module diagnostics
3 A removable screw terminal block for connection of the c24 V external power
supply, the sensors and the pre-actuators
4 A latching mechanism for attachment to the previous module
These modules are mounted on a symmetrical 7 rail. Mounting kit TWD XMT 5
(supplied in lots of 5) allows plate or panel mounting.
(1) A connector on the right-hand side panel ensures continuity of the electrical link with the next
I/O module.
Presentation
Description
1
2
3
4
33
Characteristics
Twido programmable controller 0
Analog I/O modules
General characteristics
Temperature C Operation: 0+ 55. Storage: - 25+ 70.
Relative humidity 30 to 95 %, without condensation
Degree of protection IP 20
Altitude m Operation: 02000. Storage: 03000.
Vibration resistance Mounted on rail Hz 1057, amplitude 0.075 mm, acceleration 57150 Hz
m/s
2
9.8 (1 gn)
Plate or panel mounted
(using mounting kit TWD XMT 5)
Hz 225, amplitude 1.6 mm, acceleration 25100 Hz
m/s
2
39.2 (4 gn)
Shock resistance m/s
2
147 (15 gn) for 11 ms
Analog input characteristics
Module type TWD AMI 2HT/AMM 3HT TWD ALM 3LT
Number of channels 2 high-level inputs 2 low-level inputs
Voltage Current Thermocouple Temperature probe
Range 010 V 420 mA Type K (01300C)
Type J (01200C)
Type T (0400C)
Pt probe,
3-wire type
(- 100500C)
Type Non differential Differential
Resolution 4096 points (12 bits)
LSB value 2.5 mV 4 A 0.325C (type K)
0.3C (type J)
0.1C (type T)
0.15C
Connection Removable screw terminal block
Permissible continuous overload c 13 V 40 mA
External supply V Rated voltage: c 24. Voltage range: c 20.428.8
Input impedance 1 M min 10 250 max 5 max
Maximum sampling duration ms 16 50
Sampling repetition time ms 16 50
Acquisition period ms 32 + 1 controller cycle time 100 + 1 controller cycle time
Measuring precision Maximum error at 25C % PE 0.2 0.2 + precision of
cold junction
compensation
( 4C max)
0.2
Temperature coefficient % PE/C 0,006
Repeat accuracy
after stabilization time
% PE 0.5
Non linearity % PE 0.2
Total error % PE 1
Common mode rejection - 50 dB
Cross talk 2 low significance bits max.
Cabling Twisted shielded pair recommended
Dielectric strength V rms a 500 between the input and the supply circuit
Type of protection Photocoupler between the input and the internal circuit
Consumption Internal supply c 5 V mA 50
External supply c24 V mA 60
34
Characteristics (continued)
Twido programmable controller 0
Analog I/O modules
Analog input characteristics (continued)
Module type TWD AMI 4LT TWD ARI 8HT TWD AMI 8HT
Number of channels 4 inputs 8 inputs 8 inputs
Temperature Current Voltage Temperature Current Voltage
Range PT100,
PT1000,
Ni100,
Ni1000
020 mA 010 V NTC, PTC,
100 <R<10
k
020 mA 010 V
Type Differential Non differential Differential Non differential
Resolution 12 bits 10 bits
LSB value 9 mV 20 A 2.5 mA 4 A
Connection Removable screw terminal block
Permissible continuous overload 13 V 40 mA 40 mA 13 V
External supply V Rated voltage: c 24. Voltage range: c 20.428.8
Input impedance >1 M 470 1 M >1 M 470 1 M
Maximum sampling duration ms 160
Sampling repetition time ms 4 8
Acquisition period ms 640 + 1 controller cycle time 1280 + 1 controller cycle time
Measuring precision Maximum error at 25C % PE 0.5 1
Consumption Internal supply c 5 V mA 50 50
External supply c24 V mA 60 50
Applicable load
Dielectric strength 2500 V between the inputs and the internal circuit
Analog output characteristics
Module type TWD AMO 1HT/AMM 3HT/ALM 3LT TWD AVO 2HT
Number of channels 1 output 2 outputs
Voltage Current Voltage
Range 010 V 420 mA 10 V
Resolution 4096 increments (12 bits) 11 bits + sign
LSB value 2.5 mV 4 A 4.8 mV
Load impedance 2000 min 300 max 3000 min
Applicable load Resistive
Stabilization time ms 20 0.3
Total output system transfer time ms 20 + 1 controller cycle time 0.3 + 1 controller cycle time
External supply V Rated voltage: c 24. Voltage range: c 20.428.8
Measuring precision Maximum error at 25C % PE 0.2
Temperature coefficient % PE/C 0.015
Repeat accuracy
after stabilization time
% PE 0.5
Output error % PE 1
Non linearity % PE 0.2
Output ripple 1 low significance bit max.
Total error % PE 1
Cabling Twisted shielded pair recommended
Dielectric strength V rms a 500 between the input and the supply circuit
Consumption
(for TWD AMO 1HT)
Internal supply c 5 V mA 50 50
External supply c24 V mA 40 60
Applicable load Resistive
Dielectric strength 2500 V between the outputs
and the internal circuit
35
References,
dimensions
Twido programmable controller 0
Analog I/O modules
These analog I/O expansion modules are mounted on symmetrical 7 rails to the
right of the Twido base controller. The sensors/pre-actuators are connected to a
removable screw terminal block (supplied with each module). The maximum number
of I/O and/or analog modules which may be mounted depends on the type of base
controller:
References
Type of
TWD
controller
LCpA
10DRF
LCpA
16DRF
LCpA
24DRF
LCpA
40DRF
LMDA
20DpK
LMDA
20DRT
LMDA
40DpK
Number of
modules
0 0 4 7 4 7 7
TWD AMI 2HT
TWD ALM 3LT
Analog input modules
Channel
type
Input
range
Output
range
Resolution Reference Weight
kg
2 inputs 010 V
420 mA
12 bits TWDAMI2HT 0.085
4 inputs 010 V
020 mA
Temperature
12 bits TWDAMI4LT 0.085
8 inputs 010 V
020 mA
10 bits TWDAMI8HT 0.085
8 inputs PTC/NTC 10 bits TWDARI8HT 0.085
Analog output modules
1 output 010 V
420 mA
12 bits TWDAMO1HT 0.085
2 outputs 10 V 11 bits + sign TWDAVO2HT 0.085
Analog I/O modules
2 inputs and
1 output
010 V
420 mA
010 V
420 mA
12 bits TWDAMM3HT 0.085
Thermocouple
K, J, T
Temperature
probe
Pt 100
010 V
420 mA
12 bits TWDALM3LT 0.085
Separate components
Application Description Reference Weight
kg
Mounting kit For plate or panel mounting
of the analog modules
Sold in lots of 5
TWDXMT5
Telefast pre-wired system
for Twido
Connection sub-bases
I/O connection sub-bases
Pre-wired solutions
Cables and accessories
See page 59
Dimensions
Analog I/O modules
0.14"
(3.8 mm)
0.95"
(23.5 mm)
0.17"
(4.5 mm)
3.54"
(90 mm)
0.57"
(14.6
mm)
2.75" (70 mm)
Dual Dimensions
inches
(mm)
36
Connections
Twido programmable controller 0
Analog I/O modules
Analog input modules
TWD AMI 2HT
b Fit a fuse of appropriate size for the sensor type.
b Do not connect any wires to the unused channel.
TWD AMI 4LT
Voltage/Current configuration PT100/PT1000 temperature probe, Ni100/Ni1000 configuration
TWD AMI 8HT TWD ARI 8HT
(1) Analog current/voltage output peripheral.
b Fit a fuse of appropriate size for the sensor type.
b Do not connect any wires to the unused channel.
+
NC
IN 0
IN 1
+
24 V
24 V
+
Voltage/current
sensor
Voltage/current
sensor
+
NC
NC
NC
NC
0 V
0 V
IN 0
0-20 mA
IN 1
IN 2
IN 3
+
24 V
24 V
+
0-10 V
0-20 mA 0-10 V
0-20 mA
+
0-10 V
0-20 mA 0-10 V
+
A
0 V
B'
A
A
B'
B
B'
B
A
A
A
B'
B'
B'
B
PT100PT100
Ni100Ni1000
PT100PT100
Ni100Ni1000
+
c 24 V
c 24 V
A
A
B'
A
B'
B
B
B'
B
PT100PT100
Ni100Ni1000
PT100PT100
Ni100Ni1000
+
0 V
0 V
IN 0
IN 1
IN 5
IN 6
IN 4
IN 2
IN 7
IN 3
+
+
24 V
24 V
+
+
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
+
+
0 V
0 V/B
A 0
A 1
A 5
A 6
A 4
A 2
A 7
A 3
+
24 V
24 V
PTC/NTC
PTC/
NTC
PTC/NTC
PTC/NTC
PTC/NTC
PTC/NTC
PTC/NTC
PTC/NTC
PTC/NTC
37
Connections (continued)
Twido programmable controller 0
Analog I/O modules
Analog output modules
TWD AMO 1HT TWD AVO 2HT
b Fit a fuse of appropriate size for the sensor type.
b Do not connect any wires to the unused channel.
Mixed input/output module
TWD AMM 3HT TWD ALM 3LT
b Fit a fuse of appropriate size for the sensor and pre-actuator types.
b For a Pt 100 3-wire temperature probe (RTD), connect the three wires to terminals A, B' and
B (channels IN0 and IN1).
b For a Pt 100 2-wire temperature probe (RTD), connect the two wires to terminals A and B'
and make a bridge between B' and B (channels IN0 and IN1).
b For a thermocouple, connect the two wires to the + and - terminals (channels IN0 and/or IN1).
b Do not connect any wires to unused channels.
+
OUT
+
24 V
24 V
Voltage/current pre-
actuator
+
+
+
OUT 1
OUT 2
+
24 V
24 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
Analog voltage input
peripheral
Analog voltage input
peripheral
+
NC
IN 0
OUT
IN 1
NC
+
+
24 V
24 V
+
Voltage/current pre-
actuator
Voltage/current
sensor
Voltage/current
sensor
+
NC A
B'
B
A
B'
B
A
B'
B
IN 0
OUT
IN 1
+
+
NC
+
+
24 V
24 V
Voltage/current pre-
actuator
Pt 100
temperature probe
Thermocouple K, J, T
38
Presentation,
description,
diagnostic 0
Twido programmable controller 0
Master module for AS-Interface cabling system
Presentation
Master module TWD NOI 10M3, for AS-Interface cabling system allows the Twido
controller (version u 2.0) to perform the function of AS-Interface master.
The cabling system consists of a master station (Twido controller) and slave stations.
The master, which supports the AS-Interface profile, polls each of the devices
connected to the AS-Interface cabling system, in turn, and stores information
gathered (sensor/actuator status, operating status of the devices) in the controller
memory. Communication on the AS-Interface cabling system is managed in a way
that is totally transparent to the Twido application program.
The TWD NOI 10M3 master module manages the following with the AS-Interface M3
profile:
b discrete slave modules (maximum of 62 slaves arranged in 2 banks, A and B, of
31 addresses each)
b analog slaves (maximum of 7 slaves in bank A)
The AS-Interface M3 profile supports analog profile 7.3 (7 slaves), but does not
support analog profile S-7.4.
The maximum number of TWD NOI 10M3 modules per Twido controller is 2.
7 discrete, analog and AS-Interface I/O modules are controlled by TwidoSoft
software, see page 64.
An AS-Interface power supply is essential to supply the various modules on the
cabling system. It should preferably be located close to the stations with high power
consumption.
For more information on power supplies, see pages 10 and 16.
Description
Module TWD NOI 10M3 takes the form of a standard-size module. It is connected to
a Twido base controller (compact or modular) in the same way as any I/O module.
It has the following on the front panel:
1 A display block comprising:
b 6 pilot lights indicating the module operating modes:
v green PWR pilot light: module powered up
v red FLT pilot light: error in the configuration loaded
v green LMO pilot light: module in local mode
v green CMO pilot light: module in connected mode
v red CNF pilot light: not used
v red OFF pilot light: module in protected, unconnected mode
b 6 green pilot lights, 3 for inputs, 3 for outputs:
2 A block for displaying the status of the addresses
3 Two push buttons PB1 and PB2 for controlling the status of the slaves by selecting
their address and changing the mode
4 An extension connector for electrical connection to the previous module
5 A connector (on the RH side) for I/O expansion modules TWD Dpp and TWD App
(4 or 7 depending on version)
6 A latching mechanism for attachment to the previous module
7 A power supply removable screw terminal block
Diagnostics
The 30 pilot lights on the front panel of the module are used in conjunction with the
two push buttons for diagnostics by the Twido controller.
The display block on the front panel of master module TWD NOI 10M3 allows
simplified local diagnostics to be performed by displaying the slaves present on the
AS-Interface cabling system.
Software set-up
The AS-Interface cabling system is configured by the TwidoSoft software, see pages
64 to 71.
The services offered are based on the principle of simplicity:
b Management of profile tables, parameters and data by the master is done, in a way
that is transparent to the user.
b Topological addressing of I/O: any AS-Interface slave defined on the cabling
system has a topological address assigned to it, in a way that is transparent to the
user.
Each AS-Interface module sensor/actuator is seen by the Twido programmable
controller in the same way as any In-rack I/O.
Sensors
Power supply
Control
station
Twido controller
+ master module
TWD NOI 10M3
AS-Interface
cabling
system
Indicator
bank
Safety
monitor
Motor
starter
Safety
interface
XBL
Keypad
1
4
2
6
5
3
7
39
Characteristics,
references,
dimensions,
connection 0
Twido programmable controller 0
Master module for AS-Interface cabling system
General characteristics
Module type TWD NOI 10M3
AS-Interface profile AS-Interface M3, V 2.11 (profile S-7.4 not supported)
Type of addressing Standard and extended
Product certifications AS-Interface n47801
Degree of protection IP 20
Altitude m Operation: 02000. Transport: 03000
Temperature C Operation: 0+ 55. Storage: - 25+ 70
Relative humidity 30 to 95 % (without condensation)
Degree of pollution 2 conforming to IEC 60664
Immunity to corrosion Free of corrosive gases
Vibration
resistance
Mounted on 5 rail Hz 1057, amplitude 0.075 mm,
57150 (acceleration: 9.8 m/s
2
); for 2 hours on all 3 axes
Plate or panel mounted
(using mounting kit TWD XMT5)
Hz 225, amplitude 1.6 mm,
25100 (acceleration: 39.2 m/s
2
); for 90 minutes on all 3 axes
Shock resistance m/s
2
147 (15 gn) duration 11 ms, on all 3 axes
As-Interface external power supply c V 29.531.6
Internal current At c 5 V mA 80
At c 24 V mA 0
AS-Interface consumption at c 24 V mW 540
Communication characteristics
As-Interface
cabling system
cycle time
With 1 to 19 slaves ms 3
With 20 to 62 slaves ms 0.156 x (1 + N) where N = number of active slaves
With 31 standard slaves
or slaves in banks A and B
ms 5
With 62 slaves in banks A and B ms 10
Max. no.
of modules
Analog modules (1) 7
Discrete modules (1) 62
Max. no. of I/O Standard slaves 248 = 124 inputs + 124 outputs
Slaves in banks A and B 434 = 248 inputs + 186 outputs
Max. length of
AS-Interface cable
Without splitter block or extension m 100
With a total of 2 splitter blocks or extensions m 300
AS-Interface cabling system voltage c V 30
References
Description Number per
controller
Protocol/profile Number of I/O
(1)
Reference Weight
kg
AS-Interface master module
for Twido programmable
controllers V u 2.0
2 AS-Interface/M3 62 discrete modules max.,
7 analog modules max.
TWDNOI10M3 0.085
Description Description Reference Weight
kg
Mounting kit For plate or panel mounting of the module
Sold in lots of 5
TWDXMT5
Description Power supply Length
m
Reference Weight
kg
Flat cable for
AS-Interface cabling system
(yellow)
For AS-Interface cabling system 20 XZCB10201 1.400
50 XZCB10501 3.500
100 XZCB11001 7.000
(1) When analog and discrete modules are connected simultaneously to the network, the analog modules use addresses 1 to 31
in bank A. When an analog module uses a certain address, the module addresses having the same number in bank B cannot
be occupied for slaves in banks A/B.
Dimensions Connection
TWD NOI 10M3 TWD NOI 10M3
TWD NOI 10M3
0
.
1
7
(
4
.
5
)
2.75
(70)
3
.
5
4
(
9
0
)
0.37
(9.4)
0.15
(3.8)
0.92 (23.5)
Dual Dimensions
inches
(mm)
Brown wire
Blue wire
As-Interface
flat cable
40
Presentation,
description 0
Twido programmable controller 0
Communication
In order to communicate with an intelligent environment, Twido compact and modular
programmable controllers offer an RS 485 serial communication port on the
modules, an optional type RS 485 or RS 232 link and, for compact base controller
TWD LCAE 40DRF, an integrated RJ45 Ethernet port (Modbus TCP).
These three ports allow Twido compact and modular controllers to use six
communication protocols: Programming, Modbus, CANopen, Ethernet, ASCII and
Remote link.
Twido compact (TWD LCpA 24DRF or TWD LCAp 40DRF) or modular base
controllers can also accommodate the CANopen bus master module TWD NCO1M.
TwidoPort interface module 499 TWD 01100, used in conjunction with a compact or
modular Twido programmable controller version 3.0 allows communication on the
Ethernet network under Modbus TCP. This solution, which is easy to connect and
configure, is transparent to the application.
Compact base controllers have the following on the front panel:
1 An RS 485 serial port, with mini-DIN type connector, for connection to the
programming terminal
2 A slot for fitting a 2
nd
optional port (RS 485/RS 232) using TWD NAC ppp
adapters
Modular base controllers have the following on the front panel:
1 An RS 485 serial port, with mini-DIN type connector, for connection to the
programming terminal
The slot for fitting a 2
nd
optional port (RS 485/RS 232) using adapters TWD NAC ppp
is located behind the removable cover 2 of a TWD NOZ pppp interface module 3 or
a TWD XCP ODM display module 4
The interface and display modules connect to the left-hand side of modular base
controllers.
Presentation
Modbus network
Ethernet network
CANopen
bus
Description
1
2
TWD NAC
485D/232D
TWD NAC
485T
Compact base
controller
or
Modular base
controller
TWD NAC
485D/232D
TWD NAC
485T
TWD NOZ pppp
1
or
3 4
2
or +
TWD XCP ODM
Twido controller communication ports
Serial port Integrated
Ethernet port
Optional port (2
nd
port)
RS 485
mini-DIN
RJ45 RS 485
mini-DIN
RS 232
mini-DIN
RS 485
screw
terminal block
Compact base controllers
All compact
base controllers
TWD LCpA pppp
TWD LCAp 40DRF
Compact base
controller
TWD LCAE 40DRF
TWD NAC 485D
(1)
TWD NAC 232D
(2)
TWD NAC 485T
(1)
Modular base controllers
All modular
base controllers
TWD LMDA pppp
TWD NOZ 485D
(1)
or
TWD XCP ODM
+
TWD NAC 485D
TWD NOZ 232D
(2)
or
TWD XCP ODM
+
TWD NAC 232D
TWD NOZ 485T
(1)
or
TWD XCP ODM
+
TWD NAC 485T
(1) With max. cable length: 200 m.
(2) With max. cable length: 10 m.
Note: if the RS 232 physical layer is used, and for a length greater than 10 metres, use the
RS 485 physical layer and an RS 232C/RS 485 line adapter reference XGS Z24.
41
Presentation,
description,
configuration,
characteristics 0
Twido programmable controller 0
Communication
CANopen bus master module
Master module TWD NCO1M for the CANopen bus allows Twido programmable
controllers version 3.0 - compact controller models TWD LCpA 24DRF or
TWD LCAp 40DRF and all modular controllers - to act as CANopen master.
The bus consists of a master station, the Twido controller and slave stations. The
master is in charge of configuration, exchanges and diagnostics on the slaves.
The CANopen bus is a communication type bus and allows management of various
slaves such as:
b Discrete slaves
b Analog slaves
b Variable speed controllers
b Motor starters
The Twido CANopen master controls up to 16 slaves, each with an input PDO
(Process Data Object) and an output PDO.
If a slave has more than one PDO, the maximum number of slaves managed is
reduced by that number. The Twido CANopen master can control a maximum of 16
input PDO and 16 output PDO.
CANopen bus master module TWDNCO1M comprises:
1 An grounded, 3-way, c 24 V supply connector
2 A PWR LED, indicating module power ON or OFF
3 A 9-way SUB-D connector for connection to the CANopen bus
4 An ground screw
5 A connector for connection to the Twido controller or to another I/O expansion
module
The Twido controller's CANopen bus is configured using TwidoSoft software version
3.0.
The various services offered are:
b Selection of the slave type from a list that can be modified by simply importing a
description file of the EDS (Electronic Data Sheet) type
b The position of the slave on the bus: definition of the slave number
b Selection of variables from the list of variables managed by the slave
b Linking of variables to the exchange data
b Symbolization of exchange data
For certain slaves, such as ATV 31 variable speed controllers, one or more profiles
are supplied allowing the slave to be configured according to a mode predefined by
Schneider Electric. The use of profiles provides the user with an operating mode that
is described, without having to configure it.
Presentation
Description
TWD NCO1M
1
2
3
4
5
5
3
2
6
5
9
Configuration
Characteristics
Module type TWD NCO1M
Operating temperature C 055
Storage temperature C - 25+70
Relative humidity 3095 % (without condensation)
Level of pollution
conforming to IEC 60664-1
Housing 3
PCB 2
Degree of protection IP 20
Immunity to corrosion Against corrosive gases
Altitude Operation m 02000
Transport m 03000
Vibration resistance Rail mounting 1057 Hz with an amplitude of 0.075 mm,
57150 Hz with an acceleration of 9.8 m/s
2
(1 gn),
Duration: 2 hours per axis on each of the three axes perpendicular to each other.
Plate or panel mounting
(using mounting kit TWD XMT5)
225 Hz with an amplitude of 1.6 mm,
25100 Hz with an acceleration of 39.2 m/s
2
(4 gn),
Duration: 90 min per axis on each of the three axes perpendicular to each other.
Shock resistance Conforming to IEC 61131 147 m/s
2
(15 gn), duration 11 ms, 3 impact shocks per axis, on the three axes
perpendicular to each other.
Permissible voltage variation c V 19.230
Protection against polarity inversion on the bus inputs Yes
CANopen bus interface connector 9-way SUB-D
Current consumption At c 5 V mA 50 (internal bus)
At c 24 V mA 50.5 (internal supply)
Power dissipated W 1.2 (at c 24 V)
42
Presentation,
description,
characteristics 0
Twido programmable controller 0
Communication
TwidoPort interface module
TwidoPort module 499 TWD 01100 is an Ethernet interface that is easy to use and
dedicated to a compact or modular Twido programmable controller version 3.0. It
allows incorporation of the Twido controller into an Ethernet network as a passive
device (slave). With version 3.0 of TwidoSoft software and of the Twido operating
system, the TwidoPort module is ready for use.
When connected to the RS 485 port of the Twido programmable controller, the
TwidoPort module acts as a gateway between the Ethernet network and the Modbus
network.
The connecting cable is supplied with the module.
The main characteristics of the TwidoPort module are as follows:
b Connects to the RS 485 port of the Twido controller; no external auxiliary supply
is necessary
b Automatic detection of the serial link configuration
b Ethernet interface:
v 10/100 Mbit/s
v Auto MDIX function
v RJ45 type connector
b Ethernet configuration:
v takes the Ethernet configuration from the Twido application configuration (normal
mode)
v BootP function
v supports manual configuration using Telnet
b Provides Ethernet statistics via a Telnet session
TwidoPort 499 TWD 01100 interface module comprises:
1 Five LEDs (SER ACT, STATUS, LINK, 100 MB, ETH ACT) indicating
performances associated with the TwidoPort module
2 An RJ45 connector for connection of the power supply and communications to the
RS 485 on the Twido controller, cable TWD XCA RJP03P supplied (1)
3 An RJ45 connector (accessed through the bottom of the module) for connection
to the Ethernet TCP/IP network
4 An grounding screw (accessed through the bottom of the module)
Presentation
Description
499 TWD 01100
2
1
3
4
5
3
2
7
1
8
Characteristics
Module type 499 TWD 01100
Operating temperature C 055
Storage temperature C - 40+70
Relative humidity 1095 % (without condensation)
Level of pollution Conforming to IEC 60664-1 2
Degree of protection IP 20
Immunity to corrosion Against corrosive gases
Altitude Operation m 02000
Storage m 03040
Vibration resistance Rail mounting 1057 Hz with an amplitude of 0.075 mm (peak to peak),
57100 Hz with constant acceleration of 9.8 m/s
2
(1 gn),
Duration: 10 cycles at 1 octave/min for each of the 3 perpendicular axes.
Shock resistance Conforming to IEC 61131-2 147 m/s
2
(15 gn), duration 11 ms, 3 impact shocks for each of the 3 perpendicular
axes.
Max. consumption At c 5 V mA 180
Supply voltage c V 5 0.5
(1) Cable TWD XCA RJP03P, connected to port 1 on the Twido controller, forces configuration of the port according to the parameters of the Programming protocol.
Using cable TWD XCA RJP03, sold separately, allows port 1 of the Twido controller to be used with the parameters described in the application configuration.
43
Presentation,
characteristics 0
Twido programmable controller 0
Communication
Communication protocols
Programming protocol
Link by modem
1 Remote programming PC
2 Cable TSX PCX 1031 on serial port (Rx/Tx crossing to be made or use cable
TSX PCX 1130)
3 Modem for transmitting/receiving data
4 Telephone or radio link
5 Twido compact or modular controller
Link by cable
1 Programming PC
6 Cable TSX PCX 1031 on RS 485 serial port or cable TSX PCX 3030 on USB port
for Windows 2000 or XP
7 Twido compact or modular controller
Wireless link
1 Programming PC with integrated Bluetooth technology or Bluetooth gateway for
PC, reference VW3 A8115
2 Pocket PC with TwidoAdjust software
For optimum performance, use a Pocket PC with integrated Bluetooth technology.
3 Bluetooth gateway VW3 A8114
4 Twido compact or modular controller
Characteristics
Protocol type Programming
Flow rate Kbit/s 19.2
Physical layer RS 485
Connection Serial port
Compatibility Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and
modular base controllers TWD LMDA pppp
Modbus protocol
Twido controller connected directly on the Modbus network
1 Magelis compact display XBT N40p
2 Cable XBT Z978 on serial port
3 Cable for optional RS 485 port, reference TWD XCA RJ0pp
4 Twido modular controller
5 Modbus hub LU9 GC3
6 Modbus tap link cable VW3 A8 306 Rpp
7 Line end adapters VW3 A8 306 RC
8 Modbus T-junctions VW3 A8 306 TFpp (with cables)
9 Twido compact controller
10 Devices: Altistart 48 starters, Altivar 28, Altivar 31 variable speed drives, Modbus
OTB I/O interface module, Zelio Logic SR3 smart relay and TeSys motor starters
Characteristics
Protocol type Modbus
Flow rate Kbit/s 1.238.4
Initial value: 19.2
Data bits 7 or 8
Initial value: 8
Stop bits 1 or 2
Parity Without, even or odd
Initial value: without
Physical layer RS 485/RS 232 (point-to-point)
Connection Serial port (RS 485) or optional port (RS 485/RS 232)
Compatibility Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and
modular base controllers TWD LMDA pppp
1
3
4
3
5
2
7
6
1
2
3
4
OR
7
6 6
6 5 8 8 7
9
3
1
10
2
4 3
Modbus network
Modbus network
44
Presentation (continued),
characteristics (continued) 0
Twido programmable controller 0
Communication
Communication protocols
CANopen protocol
Direct connection of the Twido CANopen master module
1 Magelis compact display XBT N40p and cable XBT Z978 on serial port
2 Twido compact controllers TWD LCpA 24DRF or TWD LCAp 40DRF or Twido
modular controllers, version 3.0
3 Twido TWD NCO1M CANopen bus master module
4 CANopen FTB I/O splitter box r
5 ATV 31 starter
6 CANopen OTB I/O interface module r
r Available 2
nd
quarter 2005.
Characteristics
Protocol type CANopen
Transmission Flow rate Kbit/s 125500
Medium Double shielded twisted pair
Structure Type EN 50325 - ISO 11898
Method CSMA-MA
Configuration Maximum number of devices 16
Maximum length of bus m 1000
Compatibility Compact base controllers TWD LCpA 24DRF and TWD LCAp 40DRF and modular
base controllers TWD LMDA pppp, version 3.0
Ethernet protocol
Twido controller connected directly on the Ethernet network
1 Magelis compact display XBT N40p and cable XBT Z978 on serial port
2 Twido master or slave, 40 I/O compact base controller TWD LCAE 40DRF
3 Premium automation platform (1)
4 Twido slave, compact or modular base controller
5 TwidoPort 499 TWD 01100 interface module
6 ConneXium 499 NEH 104 10 hub or ConneXium 499 NES 251 00 switch
7 Ethernet OTB I/O interface module r
8 Web Factory Cast Gateway TSX ETG 1000 (2)
r Available 2
nd
quarter 2005.
Characteristics
Protocol type Ethernet
Transmission Flow rate Mbit/s 10100
Medium Double twisted pair
Services
Transparent Ready
Class A 15 (for Twido controller TWD LCAE 40DRF and TwidoPort interface module
499 TWD 01100),
C 20 (for gateway TSX ETG 1000)
Web Server
(function provided by
gateway TSX ETG 1000)
Access to the product description and status and to the Rack Viewer island diagnostics
Access to configuration functions and to Data editor variables
Loading of user Web pages via the Web page loader software tool
Ethernet TCP/IP communication
management services
(services supported by
controllers in the Twido range)
Modbus messaging (read/write of data words)
I/O Scanning (Twido controllers version 3.0)
Structure Type 10BASE-T/100BASE-T
Method CSMA-CD
Configuration Maximum number of devices 256 max per segment
Max. length of network m 500
Compatibility Master Compact base controller TWD LCAE 40DRF
Slaves Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and modular
base controllers TWD LMDA pppp, version 3.0
(1) Please see our Premium automation platform catalog, # MKTED204032EN.
(2) Please see our Ethernet TCP/IP and the Web catalog # MKTED204073EN.
3
5 6 4
2
1
CANopen bus
4
6
2
5
1
7 8
3
Ethernet
Network
Ethernet
Network
Modbus
Network
Ethernet
Network
Ethernet
Network
Modbus SL network
45
Presentation (continued),
characteristics (continued) 0
Twido programmable controller 0
Communication
Communication protocols
ASCII protocol
Link by modem
1 Simple ASCII display
2 Cable TSX PCX 1031 on serial port (Rx/Tx crossing to be made or use cable
TSX PCX 1130)
3 Modem for transmitting/receiving data
4 Telephone or radio link
5 Twido compact or modular controller
6 ASCII printer
7 Standard RS 485/RS 232 cable on optional port
Link by cable
1 Simple ASCII display
2 Standard RS 485 cable or cable TSX PCX 1031 for RS 232 conversion, on serial
port
3 Twido compact or modular controller
4 Standard RS 485/RS 232 cable on optional link
5 ASCII printer
Characteristics
Protocol type ASCII
Flow rate Kbit/s 1.238.4
Initial value: 19.2
Data bits 7 or 8
Initial value: 8
Stop bits 1 or 2
Initial value: 1
Parity Without, even or odd
Initial value: without
Physical layer RS 485/RS 232
Connection Serial port (RS 485) or optional port (RS 485/RS 232)
Compatibility Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and
modular base controllers TWD LMDA pppp
Remote link protocol
(1) Connection is made either to the serial port,
or to the optional port.
Remote Link decentralized I/O
Each compact or modular base controller can be extended by means of Twido base
controllers used either as an I/O extension, or as a local reflex controller.
v When used as an I/O extension, these base controllers cannot take any I/O
extensions.
v When used as a local reflex controller, these base controllers have their own
application program. Internal words are reserved for automatic exchange of
information between the base controllers.
1 Base controller
2 RS 485, 3-wire cable on serial port or on optional port
3 Twido base controllers used as I/O extension or as local reflex controller
Characteristics
Protocol type Remote link
Flow rate Kbit/s 38.4
Physical layer RS 485
Connection Serial port or optional port only.
Number of Twido modules that can be connected 1 to 7
Compatibility Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and
modular base controllers TWD LMDA pppp
1
6
3
3
4
4
3
3
5
2
7
1
5
3
2
4
1 3 3
2
(1) (1)
3
(1)
46
References 0
Twido programmable controller 0
Communication
CANopen bus master module and TwidoPort interface module
Description Number of modules
per base controller
Max. number
of slaves
and channels
External
supply
Reference Weight
kg
CANopen bus master module
for base controllers version 3.0
TWD LCpA 24DRF/LCAp
40DRF and TWD LMDA pppp
1 16 slaves max.
16 TPDO (Transmit
PDO) and 16 RPDO
(Receive PDO)
c 24 V TWDNCO1M r 0.100
Mounting kit
(sold in lots of 5)
Plate or panel mounting of module TWD NCO1M TWDXMT5
Description Characteristics Reference Weight
kg
TwidoPort interface module
for all base controllers version 3.0
10/100 Mbit/s. Auto MDIX function. RJ45 connector.
Cable TWD XCA RJP03P supplied.
499TWD01100 0.200
Ethernet network cables Fitted with 2 RJ45 connectors Length (1) 490NTW000pp
Serial link modules and adapters
Description Compatibility Connection Physical
layer
Reference Weight
kg
Modules with integrated
serial link adapter
(able to take a TWD XCP ODC
digital display)
Modular base controllers
TWD LMDA 20/40Dpp
Mini-DIN connector RS 232C TWDNOZOD232D r 0.185
RS 485 TWDNOZOD485D r 0.185
Screw terminals RS 485 TWDNOZOD485T r 0.185
Serial interface adapters Compact base controllers
TWD LCpA 16/24DRF and
TWD LCAp 40DRF
Built-in display module
TWD XCP ODM
Mini-DIN connector RS 232C TWDNAC232D 0.010
RS 485 TWDNAC485D 0.010
Screw terminals RS 485 TWDNAC485T 0.010
Modules with integrated
serial link adapter
Modular base controllers
TWD LMDA 20/40Dpp
Mini-DIN connector RS 232C TWDNOZ232D 0.085
RS 485 TWDNOZ485D 0.085
Screw terminals RS 485 TWDNOZ485T 0.085
Built-in display module
Description Application Reference Weight
kg
Built-in display module For base controllers TWD LMDA 20/40Dpp Mounted on left-hand
side of base controller. Enables adjustment and diagnostics of the
controller. Can take a serial adapter TWD NAC pppp
TWDXCPODM 0.105
Accessories
Description Link Length Reference Weight
kg
from to
Serial link connection cables Serial interface adapter or
serial interface module
RS 485 (mini-DIN connector)
Modbus module
(RJ45 connector)
0.3 m TWDXCARJ003
1 m TWDXCARJ010 0.090
3 m TWDXCARJ030 0.160
Programming protocol
connection cable (2) supplied
with the TwidoPort module
All Twido controllers
(Mini-DIN connector)
Modbus module
(RJ45 connector)
0.3 m TWDXCARJP03P
Connection cable
(2)
All Twido controllers
(Mini-DIN connector)
Modbus module
(RJ45 connector)
0.3 m TWDXCARJP03
Cable with RJ45 connector
and end with free wires
All Twido controllers Modbus module 1 m TWDXCAFJ010
Cable with 8-way Mini-DIN
connector and end with
free wires
All Twido controllers Modbus module 1 m TWDXCAFD010
10 m TSXCX100
Adapter cable for Twido
modular base controllers
Twido modular base
controllers
Cable XBT Z978 12 cm TWDXCAXBTN010
Cable for serial port All Twido controllers Serial port on PC
with TwidoSoft
software installed
2.5 m TSXPCX1031 0.225
Modem connection cable All Twido controllers Modem 2.5 m TSXPCX1130 0.240
Display connection cable All Twido controllers Magelis displays
XBT Np00
2.5 m XBTZ978 0.180
USB port cable All Twido controllers USB port on PC (3) 2.5 m TSXPCX3030 0.210
Description Application Reference Weight
kg
Bluetooth gateway Range 10 m (class 2).
Items supplied:
b 1 Bluetooth gateway with 1 RJ45 connector,
b 1 x 0.1 m length cable with two RJ45 connectors,
b 1 x 0.1 m length cable with one RJ45 connector and
one mini-DIN connector for TwidoSoft software,
b 1 x RJ45/9-way SUB-D adapter.
VW3A8114 0.155
Bluetooth gateway
for non-equipped PC
Range 10 m (class 2). Required for a PC not equipped with
Bluetooth technology. Connection to the USB port on the PC.
VW3A8115 0.300
(1) Replace the pp in the reference with 02: 2 m, 05: 5 m, 12: 12 m, 40: 40 m and 80: 80 m.
(2) Cable TWD XCA RJP03P, connected to port 1 on the Twido controller, forces configuration of the port according to the
parameters of the Programming protocol. Using cable TWD XCA RJP03, sold separately, allows port 1 of the Twido controller
to be used with the parameters described in the application configuration.
(3) PC with TwidoSoft software installed and running under Windows 2000 or XP operating system only.
TWD NOZ ppp
TWD NAC 232D/485D
TWD XCP ODM
TWD NAC 485T
VW3 A8114
TWD NCO1M
5
3
2
6
6
4
5
7
0
7
3
2
5
2
1
5
8
9
5
7
0
7
1
1
5
7
0
7
1
0
5
3
3
2
3
4
499 TWD 01100
5
4
0
3
9
3
r Available
3
rd
quarter 2005
Available
1
st
quarter 2005
47
Dimensions,
connections 0
Twido programmable controller 0
Communication
Dimensions
Module TWD NCO1M Module 499 TWD 01100
Modules TWD NOZ ppp and TWD XCP ODM
a
TWD NOZ pppp 0.88 (22.50)
TWD XCP ODM 1.49 (38)
Connections
Serial link Optional link
RS 485 RS 485D RS 232D RS 485T
TWD LCpA pppp
TWD LCAp 40DRF
TWD LMDA pppp
TWD NAC 485D
TWD NOZ 485D
TWD NAC 232D
TWD NOZ 232D
TWD NAC 485T
TWD NOZ 485T
1 D1 (A +) D1 (A +) RTS A D1 (A +)
2 D0 (B -) D0 (B -) DTR B D0 (B -)
3 NPC NC TXD SG 0 V
4 /DE NC RXD
5 /DPT NC DSR
6 NPC NC 0 V
7 0 V 0 V 0 V
8 5 V (180 mA) 5 V (180 mA) 5 V (180 mA)
NC: not connected
NPC: do not connect
/DPT: 1 = master. If not connected, the PUNIT protocol is used for communication with PCs (at state 1, 19 200 bauds, without parity). If connected to 0 V, the
communication parameters are those configured by the TwidoSoft software.
0.14
(3.8)
1.16
(29.7)
3
.
5
4
(
9
0
)
1
.
1
7
(
4
.
5
)
0.57
(14.6)
2.75
(70)
2.91
(74) 2.75
(70)
3
.
5
4
(
9
0
)
3
.
5
4
(
9
0
)
0.88
(22.5)
Dual Dimensions
inches
(mm)
2.75 (70) a
0.17 (4.5)
3.54 (90)
0.54 (13.9)
1 2
4 5 3
8 7 6
1 2
4 5 3
8 7 6
1 2
4 5 3
8 7 6
A B SG
48
Selection guide
Connection interfaces 0
Advantys, Telefast
Passive output mA
(3.2 for ABE 7
B20MPN22)
(3.2 for ABE 7
E16SPN22)
TwidoAdjust
software
packages
See page 73
Separate components
Description Application Reference Weight
kg
From To
Connecting
cables
All
Twido controllers
USB port on the PC (2)
with TwidoSoft
software installed
TSXPCX3030 0.210
Serial port on the PC
with TwidoSoft
software installed
TSXPCX1031 0.225
TwidoPack kits
Description Twido base
controller
Options Reference
(3)
Weight
kg
TwidoPack
Compact
Compact 10 I/O
TWD LCAA 10DRF
a100240 V,
relay outputs
Real-time clock
cartridge
TWD XCP RTC
6-input simulator
TWD XSM 6
TWDXDPPAK1E
TwidoPack
Modular
Modular 20 I/O
TWD LMDA 20DTK
c24V supply,
transistor outputs
Ral-time clock cartridge
TWD XCP RTC
Built-in display module
TWD XCP ODM
Serial interface adapter
TWD NAC 485T
Pre-formed cable (3 m)
TWD FCW30M
TWDXDPPAK2E
User documentation
Description Format Language Reference Weight
kg
Twido
installation
and set-up
manuals
Hardware and
software
Hard copy
(216 x 181 mm)
English TWDUSE10AE
Spanish TWDUSE10AS
(1) Typical recommended configuration: 300 MHz processor, 128 Mb of RAM with 40 Mb of
available hard disk space.
(2) PC running under Windows 2000 or XP operating system only.
Avalible 1
st
Quarter 2005
72
Presentation,
functions 0
Twido programmable controller 0
TwidoAdjust software
TwidoAdjust is a software tool dedicated to the management and animation of Twido
applications, using a Pocket PC.
The Pocket PC with TwidoAdjust software package can be connected to a Twido
programmable controller:
b either using TSX PCX 1031 and TSX PCX 1130 connection cables (ensuring
crossing of the Rx and Tx wires)
b or using Bluetooth wireless technology. For optimum performance, use a Pocket
PC with integrated Bluetooth technology.
TwidoAdjust software requires a Pocket PC with Pocket PC2003 operating system
and must be used with the stylus, since the Pocket PC buttons are not supported.
TwidoAdjust software is used to manage a project and allows:
b the transfer of applications
b animation and back-up of object tables
b back-up of object category values
From the very first screen, TwidoAdjust software offers the possibility of displaying
essential controller data, such as its reference, its status, the name of the application
and version of its firmware.
The functions offered by TwidoAdjust software are split into three groups:
The connection function establishes communication between the TwidoAdjust
software and the Twido programmable controller and allows disconnection and
access to basic data such as references, controller status and name of the
application.
The application function includes the following functions:
b transfer, such as transfer of the application, reading of an application, backup,
restore
b animation of object tables, creation, editing, table animation, capture of values
b reading the configuration of the application
The system function makes it possible to display the physical configuration of the
controller, set the RTC function clock and update the PLC's microprogram.
The operation of TwidoAdjust software can also be customized via the Action and
Preferences menus. Other types of customization are offered, such as adding
shortcuts, choice of default communication port, and opening of latest project.
Presentation
Example of TwidoAdjust software screen
5
3
2
6
3
4
Functions
Connection
Application
System
73
References 0
Twido programmable controller 0
TwidoAdjust software
References
The multi-language software packages (English, French, German, Italian and
Spanish) are for use on Pocket PCs with Pocket PC2003 operating system.
These software packages include:
b a CD-ROM containing TwidoAdjust multi-language software and multi-language
documentation for hardware and software set-up
b depending on the model, Bluetooth gateway VW3 A8114
TwidoAdjust software
Description Processor Language Composition Reference Weight
kg
TwidoAdjust
software
packages
Recommended
processor
400 MHz
Available
space 3 Mbits
Multi-
language
TWDSMD1002V30M
Supplied with
Bluetooth
gateway
VW3 A8114
TWDSMD1004V30M
Separate components
Description Composition Reference Weight
kg
Bluetooth
gateway
This gateway has a range of 10 m (class 2).
It is connected to the device by means of
various accessories:
b 1 Bluetooth gateway with one RJ45
connector
b 1 x 0.1 m length cable with two RJ45
connectors
b 1 x 0.1 m length cable with one RJ45
connector and one mini-DIN connector
for TwidoSoft software
b 1 x RJ45/9-way SUB-D adapter
VW3A8114 0.155
Description Application Reference Weight
kg
Connecting
cables (1)
For connecting Twido controller
to Pocket PC
TSXPCX1031
For connecting Twido controller to
Pocket PC with crossing of Rx and Tx wires
TSXPCX1130
(1) Connection schemes, see page 43.
Avalible 1
st
Quarter 2005
VW3 A8114
5
1
0
4
0
6
74
0
Numerics
490NTW000 . . . . . . .46
499TWD01100 . . . . .46
A
ABE7B20MPN20 . . .58
ABE7B20MPN22 . . .58
ABE7B20MRM20 . .58
ABE7BV20 . . . . . . . .58
ABE7BV20TB . . . . .58
ABE7E16EPN20 . . . .58
ABE7E16SPN20 . . . .58
ABE7E16SPN22 . . . .58
ABE7E16SRM20 . . .58
ABE7FU012 . . . . . . .58
ABE7FU030 . . . . . . .58
ABE7FU100 . . . . . . .58
ABE7FU200 . . . . . . .58
ABFC20R200 . . . . . .59
ABFT20E050 . . . . . .58
ABFT20E100 . . . . . .58
ABFT20E200 . . . . . .58
ABFT26B050 . . . . . .58
ABFT26B100 . . . . . .58
ABFT26B200 . . . . . .58
ABFTE20EP100 . . . .25
ABFTE20EP200 . . . .25
ABFTE20EP300 . . . .25
ABFTE20SP100 . . . .25
ABFTE20SP200 . . . .25
ABFTE20SP300 . . . .25
ABFTP26MP100 . . .25
ABFTP26MP200 . . .25
ABFTP26MP300 . . .25
ABL7CEM24006 . . .16
ABL7CEM24012 . . .16
ABL7RE2402 . . . . . .16
ABL7RE2403 . . . . . .16
ABL7RE2405 . . . . . .16
ASIABLM3024 . .10, 16
S
SR1KIT02 . . . . . . . . . .7
SR1MOD01 . . . . . . .47
SR1MOD02 . . . . . . .47
T
TSXCX100 . . . . . . . .46
TSXPCX1031 46, 71, 73
TSXPCX1130 . . .46, 73
TSXPCX3030 . . .46, 71
TSXPLP01 . . . . . . . .10
TSXPLP101 . . . . . . .10
TWDALM3LT . . . . .35
TWDAMI2HT . . . . .35
TWDAMI4LT . . . . . .35
TWDAMI8HT . . . . .35
TWDAMM3HT . . . .35
TWDAMO1HT . . . . .35
TWDARI8HT . . . . . .35
TWDAVO2HT . . . . .35
TWDDAI8DT . . . . . .24
TWDDDI16DK . . . . .24
TWDDDI16DT . . . . 24
TWDDDI32DK . . . . 24
TWDDDI8DT . . . . . 24
TWDDDO16TK . . . 24
TWDDDO16UK . . . 24
TWDDDO32TK . . . 24
TWDDDO32UK . . . 24
TWDDDO8TT . . . . . 24
TWDDDO8UT . . . . 24
TWDDMM24DRF . 24
TWDDMM8DRT . . 24
TWDDRA16RT . . . . 24
TWDDRA8RT . . . . . 24
TWDFBT2T10 . . . . 59
TWDFCN2K20 . . . . 59
TWDFCN2K26 . . . . 59
TWDFCN5K20 . . . . 25
TWDFCN5K26 . . . . 25
TWDFCW30K . . 25, 59
TWDFCW30M . 25, 59
TWDFCW50K . . 25, 59
TWDFCW50M . 25, 59
TWDFTB2T11 . . . . 59
TWDFTB2T13 . . . . 16
TWDFTB2T16 . . . . 16
TWDLCAA10DRF . 10
TWDLCAA16DRF . 10
TWDLCAA24DRF . 10
TWDLCAA40DRF . 10
TWDLCAE40DRF . 10
TWDLCDA10DRF . 10
TWDLCDA16DRF . 10
TWDLCDA24DRF . 10
TWDLMDA20DRT 16
TWDLMDA20DTK 16
TWDLMDA20DUK 16
TWDLMDA40DTK 16
TWDLMDA40DUK 16
TWDNAC232D . . . . 46
TWDNAC485D . . . . 46
TWDNAC485T . . . . 46
TWDNAC . . . . . . . . 10
TWDNCO1M . . . . . 46
TWDNOI10M3 . . . . 39
TWDNOZ232D . . . . 46
TWDNOZ485D . . . . 46
TWDNOZ485T . . . . 46
TWDNOZOD232D . 46
TWDNOZOD485D . 46
TWDNOZOD485T . 46
TWDNOZ . . . . . . . . 16
TWDSMD1002V30M 73
TWDSMD1004V30M 73
TWDSPU1001V10M 71
TWDSPU1002V10M 71
TWDUSE10AD . . . . 71
TWDUSE10AE . . . . 71
TWDUSE10AF . . . . 71
TWDUSE10AI . . . . 71
TWDUSE10AS . . . . 71
TWDXCA2A10M . . 16
TWDXCAFD010 . . . 46
TWDXCAFJ010 . . . . 46
TWDXCARJ003 . . . 46
TWDXCARJ010 . . . 46
TWDXCARJ030 . . . 46
TWDXCARJP03 . . . 46
TWDXCARJP03P . . 46
TWDXCAXBTN010 46
TWDXCPMFK32 10, 16
TWDXCPMFK64 10, 16
TWDXCPODC . . . . . 10
TWDXCPODM . 16, 46
TWDXCPRTC . . 10, 16
TWDXDPPAK1 . . . . 71
TWDXDPPAK2 . . . . 71
TWDXMT5 .10, 16, 25,
35, 39, 46
TWDXSM14 . . . . . . 10
TWDXSM6 . . . . . . . 10
TWDXSM9 . . . . . . . 10
V
VW3A8114 . . . . 46, 73
VW3A8115 . . . . . . . 46
X
XBTN200 . . . . . . 10, 16
XBTN400 . . . . . . 10, 16
XBTN401 . . . . . . 10, 16
XBTZ978 . . . 10, 16, 46
XGSZ24 . . . . . . . . . . 47
XZCB10201 . . . . . . . 39
XZCB10501 . . . . . . . 39
XZCB11001 . . . . . . . 39
Twido programmable controller 0
Product Reference Index
75
Twido programmable controller 0
Community regulations
Protective treatment of equipment
Opening up of European markets assumes harmonisation of the regulations
pertaining to each of the member countries of the European Union.
The purpose of the European Directive is to eliminate obstacles hindering the free
circulation of goods within the European Union, and it applies to each member
country.
Member countries are obliged to transcribe each Directive into their national
legislation and to simultaneously withdraw any contradictory regulations.
The Directives, in particular those of a technical nature which concern us, only
establish the objectives to be achieved, referred to as "essential requirements".
The manufacturer must take all the necessary measures to ensure that his products
conform to the requirements of each Directive applicable to his production.
As a general rule, the manufacturer certifies conformity to the essential requirements
of the Directive(s) for his product by affixing the e mark.
The e mark is affixed to our products concerned.
p The e mark affixed to a product signifies that the manufacturer certifies that the
product conforms to the relevant European Directive(s) which concern him; this
condition must be met to allow marketing and free circulation within the countries of
the European Union of any product subject to one or more of the E.U. Directives.
p The emark is intended solely for national market control authorities.
For electrical equipment, only conformity to standards signifies that the product is
suitable for its designed function. Only the guarantee of an established manufacturer
can provide a high level of quality assurance.
For our products, one or several Directives are likely to be applicable, depending on
the product, and in particular:
p The Low Voltage Directive 72/23/EEC amended by Directive 93/68/EEC: under
the terms of this Directive, e marking could not be applied before 1st January 1995
and has been compulsory since 1st January 1997.
p The Electromagnetic Compatibility Directive 89/336/EEC, amended by Directives
92/31/EEC and 93/68/EEC: the e mark on products covered by this Directive has
been compulsory since 1st January 1996.
Twido programmable controllers meet the requirements of TC treatment (1).
For installations in industrial production workshops or in an environment which
corresponds to TH treatment (2), Twido programmable controllers should be
enclosed in casings with a minimum of IP 54 protection as defined by standards
IEC 60950 or NEMA 250.
Twido programmable controllers are supplied with an IP 20 protection index. They
can therefore be installed without an enclosure in locations with restricted access
which do not exceed degree of pollution 2 (control room not containing machinery or
dust producing activities).
(1) TC treatment: all climate treatment.
(2) TH treatment: treatment for hot and humid environments.
Community regulations
European Directives
Significance of the
e mark
Protective treatment of equipment
D
I
A
3
E
D
2
0
4
1
1
0
2
E
N
-
U
S
Simply Smart !
The efficiency of Telemecanique
branded solutions
Used in combination, Telemecanique products provide quality solutions,
meeting all your Automation & Control applications requirements.
A worldwide presence
Constantly available
b More than 5,000 points of sale in 130 countries.
b You can be sure to find the range of products that are right for you and which
complies fully with the standards in the country where they are used.
Technical assistance wherever you are
b Our technicians are at your disposal to assist you in finding the optimum
solution for your particular needs.
b Schneider Electric provides you with all necessary technical assistance,
throughout the world.
DIA3ED2041102EN-US 2005 Schneider Electric All Rights Reserved
Schneider Electric USA
8001 Highway 64 East
Knightdale, NC 27545
1-888-SquareD
(1-888-778-2733)
www.us.SquareD.com
Schneider Electric Canada
19 Waterman Avenue,
M4B 1 Y2
Toronto, Ontario
1-800-565-6699
www.schneider-electric.ca
01/2005