This document is an axial fan catalog from ebm-papst, a leading manufacturer of ventilation and drive technology products. It provides an overview of the company and its history and product lines. The catalog contains information on ebm-papst's various axial fan series for both AC and EC motor types. It describes the different series and features such as noise levels, pressure capabilities, and control options. The document also outlines accessories, technical specifications, and contact information.

Uploaded by

chaveliux7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
599 views436 pages

Axial Fans 2007 EN PDF

This document is an axial fan catalog from ebm-papst, a leading manufacturer of ventilation and drive technology products. It provides an overview of the company and its history and product lines. The catalog contains information on ebm-papst's various axial fan series for both AC and EC motor types. It describes the different series and features such as noise levels, pressure capabilities, and control options. The document also outlines accessories, technical specifications, and contact information.

Uploaded by

chaveliux7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 436

37779-7-8811 KO-08/07-10,8

Printed in Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmhle 2
D-74673 Mulfingen
Phone +49 (0) 7938/ 81-0
Fax +49 (0) 7938/ 81-110
[email protected]
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Strae 1
D-78112 St. Georgen
Phone +49 (0) 7724/ 81-0
Fax +49 (0) 7724 / 81-1309
[email protected]
ebm-papst
Landshut GmbH
Hofmark-Aich-Strae 25
D-84030 Landshut
Phone +49 (0) 871/ 707-0
Fax +49 (0) 871/ 707-465
[email protected]
version 07
Axial fans
The engineers choice
v
e
r
s
i
o
n

0
7
A
x
i
a
l

f
a
n
s
3 2
Axial fans
ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold
air exchange in a wide variety of devices and systems. Their outstanding features are their small
installation depth, low noise level and exceptional efficiency, and are particularly well suited for air
flow through heat exchangers.
Furthermore, in the EC version, they become intelligent "energy-saving wonders" for an extremely
wide range of applications, primarily in ventilation, air-conditioning and refrigeration technology and
the automotive industry. Table of content
One principle, countless options
The axial fan, the function of which is similar to
a propeller, moves the air axially, parallel to the
revolving motor shaft. The ebm-papst external
rotor motor is integrated directly into the axial
impeller, forming a compact axial fan unit. They
are usually installed with wall rings in short or
long nozzles.
The extensive ebm-papst product range offers
the right solution for each requirement and is
classified for a wide variety of applications:
S series with sickle-shaped blades for high
air flow at medium pressure
K series with especially low noise level
ideally suited for refrigeration plant
applications
A series for high-pressure applications
is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG
Design according to requirements
Energy efficiency, controllability and low-noise
performance and all this together with
external rotor motors in AC and EC technology:
ebm-papst axial fans are optimally matched to
customer requirements.
The EC technology (12 VDC to 110 VDC or
line-voltage-powered 100 VAC to 480 VAC) with
integrated or external electronics enables
precision open and closed-loop control with
very high efficiency. The following standard
features are available:
tach output, error message, linear or PWM
input, temperature or flow rate-dependent
control systems or bus-connectable interface.
General information 4
Company profile: ebm-papst
Our key to success
How to use this catalogue
How to find your ebm-papst product
How to order your ebm-papst product
AC axial fans, AC diagonal fans 13
AC axial fans, S series 23
AC axial fans, K series 131
AC axial fans, A series 157
Square shaded-pole motors (Q-motor) 301
Energy-saving motors (ESM) 315
EC axial fans, EC diagonal fans 179
EC axial fans, S series 185
EC-SYSTEMS 329
Options
Switch power supplies
External commutation electronics for rail technology
Temperature sensor / control module
Pressure control / selection module for 3 speeds
Interface converter / RS485 repeater
RS485 terminal box / hand-held control terminal
Speed setting
LISA control software / fan control software
HMS controller
Accessories 361
Guard grilles, streamers
Wall rings
Connection leads
Accessories for Q-motors and ESM
Terminal boxes, capacitors
Speed setting
Motor protection switch
Star-delta switch / repair switch
Technology 391
Technical parameters & scope
Impellers
Motors
Control technology
Distributors, agencies and subsidiaries 430
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
3 2
Axial fans
ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold
air exchange in a wide variety of devices and systems. Their outstanding features are their small
installation depth, low noise level and exceptional efficiency, and are particularly well suited for air
flow through heat exchangers.
Furthermore, in the EC version, they become intelligent "energy-saving wonders" for an extremely
wide range of applications, primarily in ventilation, air-conditioning and refrigeration technology and
the automotive industry. Table of content
One principle, countless options
The axial fan, the function of which is similar to
a propeller, moves the air axially, parallel to the
revolving motor shaft. The ebm-papst external
rotor motor is integrated directly into the axial
impeller, forming a compact axial fan unit. They
are usually installed with wall rings in short or
long nozzles.
The extensive ebm-papst product range offers
the right solution for each requirement and is
classified for a wide variety of applications:
S series with sickle-shaped blades for high
air flow at medium pressure
K series with especially low noise level
ideally suited for refrigeration plant
applications
A series for high-pressure applications
is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG
Design according to requirements
Energy efficiency, controllability and low-noise
performance and all this together with
external rotor motors in AC and EC technology:
ebm-papst axial fans are optimally matched to
customer requirements.
The EC technology (12 VDC to 110 VDC or
line-voltage-powered 100 VAC to 480 VAC) with
integrated or external electronics enables
precision open and closed-loop control with
very high efficiency. The following standard
features are available:
tach output, error message, linear or PWM
input, temperature or flow rate-dependent
control systems or bus-connectable interface.
General information 4
Company profile: ebm-papst
Our key to success
How to use this catalogue
How to find your ebm-papst product
How to order your ebm-papst product
AC axial fans, AC diagonal fans 13
AC axial fans, S series 23
AC axial fans, K series 131
AC axial fans, A series 157
Square shaded-pole motors (Q-motor) 301
Energy-saving motors (ESM) 315
EC axial fans, EC diagonal fans 179
EC axial fans, S series 185
EC-SYSTEMS 329
Options
Switch power supplies
External commutation electronics for rail technology
Temperature sensor / control module
Pressure control / selection module for 3 speeds
Interface converter / RS485 repeater
RS485 terminal box / hand-held control terminal
Speed setting
LISA control software / fan control software
HMS controller
Accessories 361
Guard grilles, streamers
Wall rings
Connection leads
Accessories for Q-motors and ESM
Terminal boxes, capacitors
Speed setting
Motor protection switch
Star-delta switch / repair switch
Technology 391
Technical parameters & scope
Impellers
Motors
Control technology
Distributors, agencies and subsidiaries 430
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
4
Company profile: ebm-papst
The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 9,800 people in
Germany and throughout the world develop, produce and sell our motors and fans. Our global presence and
our unique range of products based on a quality standard that surpasses every other have made us what we are:
world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving
to arrive at the perfect application solution for a wide variety of different industries is what determines our daily
work. Those who know us know the high standards we apply to our work and know our creed: to be as close
to our customers as possible and to simply be the best in terms of innovation and reliability.
Our headquarters in Mulfingen
5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Left:
Our location in St. Georgen
Right:
Our location in Landshut
Our history Our drive
Rooted in ebm, PAPST and mvl, the three leading innovators in the
development and production of motors and fans, ebm-papst has
established itself as the world market leader. Now as ever, our legendary
inventive spirit shines through in products that set standards in many
segments of industry worldwide. We are proud to say that despite difficult
competition, our performance has always been exemplary and outstand-
ing in business, in our personal relationship with our customers, and of
course with respect to technology and engineering. For decades, we have
contributed to the world of air technology and drive engineering with
small revolutions and large milestones.
To maintain this advantage in skills and knowledge to get maximum
quality and thus the highest degree of customer satisfaction, our
employees around the world put their passion and dedication to work
for you.
Passionately involved in R&D
Our catalogues just list the results of our incessant efforts in R&D:
products of highest quality and reliability. After all, it is our passion to
constantly try something new and improve what we have. In doing so,
we take advantage of the latest development methods and state-of-
the-art technology and invest quite heavily in R&D facilities. Best of all,
though, we rely on excellently trained and skilled engineers and
technicians to be at your service in R&D and Sales & Distribution.
Producing and safeguarding high-quality products and services
This is our promise without any compromise. Whether produced in one of
our five factories in Germany or one of our eleven international production
sites, our products always have the same high level of quality. This quality
control is something you can definitely rely on! And this across all levels
of production and throughout all processes: consulting customers, devel-
opment, material selection through to picking certified, choice suppliers
and on to the production of parts and final delivery. On top of this, our
products have to pass the most rigourous tests under all realistic operat-
ing conditions: continuous stress test, salt spray test, vibration test, or
precision noise measuring, just to mention a few. And the product gets
clearance for serial production only after all the
desired characteristics have been determined to
be just right.
Environmental care is another priority with
ebm-papst. This is why we have developed
our product line in EC technology, which makes
for very low power consumption. Due to our
manufacturing philosophy, there is absolute
focus on environmental care in production,
recycling, waste and waste water disposal.
Global Domestic
In order to be specialist for customised solutions
throughout the world, you need strong partners.
Global Domestic i.e. being present all over the
world and being a national company in each
individual country is how we have established
ourselves in all important markets on this globe
with our successful subsidiaries. And so you will
always find ebm-papst close to home, speaking
your language, and knowing the demands of
your markets. Besides, our worldwide produc-
tion alliance serves as a basis for competitive
pricing. Our global services and logistic outlets,
i.e. IT networking, safeguard short reaction
times and just-in-time delivery.
All our efforts are documented in a comprehen-
sive quality management system, both for prod-
ucts and services. Being certified as complying
with the tough requirements of the international
standards DIN EN ISO 9001, ISO/TS 16949-2
and of standard DIN EN ISO 14001 is just one
seal of approval we have received for our
unceasing efforts to provide only the best
quality products and services.
6
Our key to success
Our innovations and technologies keep on turning into new industrial standards. This competitive capability can
only be maintained by seeing ventilation as a whole: the interrelationship between, and thus the system of, motor
engineering, aerodynamics, and electronics. These are our three core competencies, imminently connected and
linked in each of our products. And so we handle air intelligently and quietly and continue to set new standards in
drive technology. Our system solutions form the main part of our product range by now. And they will be our main
key to success.
Motor engineering, aerodynamics, electronics
Our drive is well known and famous with specialists: our external-rotor
motor, which has made us world market leader quietly, yet powerfully.
Being versatile as to integration, it is ideally suited to the most diverse
applications. Based on this principle, we here at ebm-papst have devel-
oped the widest range of fans and motor types in the world. And for hot
or aggressive blower mediums, the internal-rotor motor is the perfect
complement.
Still, in drive engineering, certain applications simply require the internal-
rotor motor principle, and they are then realised with our motors specifi-
cally developed for such cases. Take, for instance, the steering support
motor in the automotive field developed as innovation in active steering.
Be it axial or centrifugal fans, centrifugal blowers, compact fans or
tangential blowers: we always design fan blades, impeller blades and
ducted housings with the specific application in mind. We strive to
minimise noise and to optimise efficiency. This is the challenge that
we have taken up and which we meet working away powerfully
and quietly.
Finally, intelligence will become the decisive
factor on all markets in future. After all, only in
connection with electronics can drive and air
flow as a system solution have an optimal
effect in a product or application. Interfaces are
avoided, and thus potential faults and failures.
Setting new standards with EC technology
Wherever intelligent air handling is required,
where energy consumption needs to be reduced
and performance has to be maximised, there
our EC motors are your reliable answer. They do
not waste financial or natural resources.
Instead, they boost high efficiency, continuous
controllability via analogue or digital inputs,
long and maintenance-free service life, and
robustness.
Production Winding machine
7
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Without any problems, the ebm-papst EC technology allows you to realise
networked, bus-linked appliances, to integrate simple or complex controls
at low cost and to also realise time and again new, customised and
complete solutions. Here, ebm-papst excels as competent development
partner, with our experience of more than 25 years and our excellent
know-how in R & D and production also being well documented in a few
hundred national and international patents. And there is also our ability
to listen intently, to pay good attention to our customers and their
demands in order to come up with new and pioneering ideas, such as:
EC fan units for clean room technology.
As the electronics are integrated and the unit
is wired up completely and ready to plug in,
there is no need for our customers to waste
time and money on laborious wiring work.
Sensitive EC sensor fans for the automotive
industry providing optimal selection of the
air-conditioning unit in the car and, combined
with booster blowers, individual air-condition-
ing of each and every passenger seat.
EC gas blowers with commutation and
control electronics including a processor.
They are developed in such a way as to
make the blower premix the required amount
of air with the gas. Aerodynamics with these
blowers are adjusted in such a way as to
make these blowers ideal for use in very
limited space at high back pressure.
Left: Endurance test room
Centre: Shaker
Right: Measurement station
Top: Betz manometer
Left: Precision noise measurement lab
8
56
AC centrifugal fans
backward curved, 3-D, 400
Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Number of blades: 6
Direction of rotation: Clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
R4E 400 M4E 094-FA
R4E 400 M4E 094-HA
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM] 1500 2000 2500
[P
a
]
100
200
300
400
500
600
0
,5
1
,0
1
,5
2
,0
[in
H
2 O
]
2
,5
[m
3
/h]
60 Hz 50 Hz
2
1
A
1
2
B
Curves
VAC Hz rpm W A F/VDB C p. 596 f.
A2a)
1~ 230 50 1355 375 1.75 8.0 /400 -40 to +60
1~ 230 60 1480 540 2.40 8.0 /400 -40 to +50
1~ 230 50 1370 480 2.40 10.0 /450 -40 to +80
1~ 230 60 1460 700 3.15 10.0 /450 -40 to +55
A
A2a) B
C
u
r
v
e
N
o
m
in
a
l
v
o
lt
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(1
)
C
a
p
a
c
it
o
r
P
e
r
m
.
a
m
b
.
t
e
m
p
.
E
le
c
t
r.
c
o
n
n
e
c
t
io
n
(1) Nominal data in operating point with maximum load
M
a
x
.
p
o
w
e
r

in
p
u
t
(1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(1
)
1350
1380
1370
1390
n
[rpm]
P1
[W]
I
[A]
370
331
469
430
1.75
1.58
2.37
2.17
A
B
A
B
1
2
2
1
LpA
[dB(A)]
64
65
66
68
R4E 400 M4E 094-FA FF A2a)
1~ 230 50 1355 375 1.75 8.0 /400 -40 to +60
1~ 230 60 1480 540 2.40 8.0 /400 -40 to +50
A
1350 370 1.75 A 1 64
1
AA
How to use this catalogue
The ebm-papst catalogue combines a technical and a product-specific section.
Technical section: General information on how to select and find ebm-papst products for your specific
application is found in the chapters "Selection" (p. 10) and "Technical parameters" (p. 392).
In case you require technical background information on ebm-papst product groups, simply turn to
the chapters "Impellers" (p. 396), "Motors" (p.410) and "Control technology" (p. 414).
Product-specific section: The product-specific section is organised according to product diameters,
lines, materials and/or design principles.
Headline
The headline indicates which technology (AC or EC), which design
(centrifugal, axial, etc.), and which line (e.g. S-Range) the product belongs
to. Impeller diameter or other features are also indicated.
Part designation / Type
This key designates and identifies all
ebm-papst products and serves as
part number:
1) Type
A - axial fan
S - axial fan with guard grille
W - axial fan with wall ring
V - axial combination
R - centrifugal fan, single inlet
G - centrifugal blower, single inlet (with scroll housing)
B - centrifugal fan, dual inlet
D - centrifugal blower, dual inlet (with scroll housing)
K - centrifugal combination
M - motor
P - pumps
2) Number of poles (AC) / number of cores (EC)
2-, 4-, 6-, 8- and 12-pole (Z = 12) / 1- and 3-core
3) Motor type
D - 3-phase motor
E - single-phase motor with operating capacitor
G - EC motor
S - shaded-pole motor
Q - square shaded-pole motors
4) Impeller diameter in mm
5) Key for mechanical design
6) Key for electrical design
7) Key for mechanical variants
R 2 E 190 -AO 26 -05
1 2 3 4 5 6 7
What a product page is made up of (reduced scale - 50%)
9
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Mounting dimensions
57
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Centrifugal fan
R4E 400-AR05 -06
R4E 400-AP17 -06
Dimensions
b c d e g
141.0 172.0 128.0 50.0 90.0
164.0 193.0 148.0 70.0 113.0
kg
7.1
8.8
Inlet nozzle
(long)
54476-2-4013
54476-2-4013
2
b
g
5
e
d 1
c 1
1
2
4

2
6
8

4
0
4
2
5
7

3
7
0

66
9
0
5
0
2
2
0
,3
1
1
5

M6
45
-
0
,4
1
0
0

6
0
0
M
a
s
s

o
f

c
e
n
t
r
if
u
g
a
l
f
a
n
Capacitor
p. 560 f.
Guard grille
p. 553
Inlet nozzle
p. 550
Electr. connections
p. 596 f.
28
5
5

100

115
7
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

c
e
n
t
r
i
f
u
g
a
l
,
b
a
c
k
w
a
r
d
A
C

c
e
n
t
r
i
f
u
g
a
l
,
f
o
r
w
a
r
d
E
C

c
e
n
t
r
i
f
u
g
a
l
,
b
a
c
k
w
a
r
d
E
C

c
e
n
t
r
i
f
u
g
a
l
,
b
a
c
k
-
w
a
r
d

f
o
r

c
l
e
a
n

r
o
o
m
s
E
C

c
e
n
t
r
i
f
u
g
a
l
,
f
o
r
w
a
r
d
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
R4E 400-AR05 -06 141.0 172.0 128.0 50.0 90.0 7.1 54476-2-4013
Brass lead tips
Depth of screw
max. 12 mm
Product description
Depending on the product, information is provided here on the following:
material, number of blades, direction of air flow, direction of rotation,
system of protection, insulation class, mounting position, condensate
discharge holes, mode of operation, design, bearing, technical equipment,
EMC, leakage current, motor protection, electrical connection, cable exit,
protection class, capacitor, product conforming to standards, approvals
and options.
Nominal data
AC products (up to motor size 074) and EC products (DC-fed):
Free-blowing or at minimal backpressure
AC products (from motor size 094) and EC products (AC-fed):
In operating point at maximum load
Graphic rendition of products
All drawings represent the design principle and are not to scale.
Dimensions are either given in the product drawing or, with varying
dimensions, in the table of dimensions given above the drawing.
Indication of relevant accessories and additional information
The pages indicated at the bottom refer to the accessories, e.g. inlet
nozzles, guard grilles, wall rings, etc. for this particular product,
as well as additional information (e. g. the connection diagram).
Curves and operating points
The diagram gives air performance curves pertaining to the product.
Refer to the operating point table to the right for information on speed,
power consumption, current draw, sound level or sound pressure level
and overall efficiency of the impeller.
10
How to select your ebm-papst product
Solutions for ventilation offered by ebm-papst
In the field of ventilation, ebm-papst offers the perfect solution for a vast number of applications. Depending on motor,
impeller and control technology, there is almost no limit to the number of possible combinations, thus making sure you can
find the best solution for your application.
Criteria for selection
When selecting a fan for a specific application, these parameters play an
important role:
Air flow with given back pressure
Voltage supply, divided into DC and AC voltage (1~, 3~)
Noise generation
Efficiency
Available mounting space
Selecting a fan
The following diagram shows the range of characteristic curves for the
most important fan designs and serves as a helpful tool in preselecting
a design on the basis of air flow and back pressure.
Characteristic curves of the various designs
axial fans
centrifugal fans, backward curved
centrifugal blowers, single inlet
centrifugal blowers, dual inlet
diagonal fans
[m/h]
[
P
a
]
1000 200 500 2000 5000 10000 20000 50000
200
400
600
800
1000
1200
11
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
How to order your ebm-papst product
Have you found the suitable ebm-papst product and would like to order it now?
In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone.
Don't know exactly which ebm-papst product you need to order?
In this case, simply contact your nearest ebm-papst sales office by
E-mail, fax or phone. Our specialists in ventilation and drive technology
are always there to help you find the best solution for your specific
application.
Using the questions provided in the checklist here as a guideline, you can
make sure your ebm-papst contact has all the necessary information to
handle your enquiry as efficiently and quickly as possible.
How your ebm-papst product is delivered
In our order confirmation, you will find information on when, how and
where to the delivery will be made.
We deliver:
Ex works (excluding packaging)
Via freight carrier (we also use postal services for shipments
up to 30 kg)
All the other details such as packaging, freight, insurance and customs
duty will be settled with your ebm-papst contact prior to the time we
issue our order confirmation.
Is there anything else you need to know about your
ebm-papst product?
In this case, simply contact your nearest ebm-papst sales office by
E-mail, fax or phone. We have the answer to your problem and are
always glad to be able to be of assistance.
Using the questions provided in the checklist here as a guideline, you can
make sure your ebm-papst contact has all the necessary information to
handle your enquiry as efficiently and quickly as possible.
Checklist
Part designation / type
Quantity needed
Field of application
Ambient conditions (humidity, temperature, climate)
Impeller diameter
Air flow
Back pressure
Voltage supply
For your nearest sales office, please turn to page 430.
12
13
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
AC axial fans, AC diagonal fans
AC diagonal fans 208 20
AC axial fans 130 - 250 14
14
AC axial fans
130
Material:
Wall ring: Die-cast aluminium,
coated in black
Blades: Sheet steel, coated in black
Rotor: Open, coated in black
Number of blades: 7
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2S130-AA25 -01 M2S 052-CA
p. 416 f.
B)
1~ 115 50 325 2800 41 49 80 -25 to +60
1~ 115 60 380 3250 38 53 120 -25 to +80
1~ 230 50 325 2800 45 49 80 -25 to +50
1~ 230 60 380 3250 39 53 120 -25 to +70
A
W2S130-AA03 -01 M2S 052-CA B) 1.1
1.1
A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
subject to alterations
100 200 300
0 50 100 150 [CFM] 200
[
P
a
]
40
80
120
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
A
Curves
Guard grille
p. 368
1500.5
550.3

1
7
2

0
.
5
6 5

4
,
3
5
/

4
,
4
5
-
0
.
0
5

1
6
2
+
0
.
1
-
0
.
3
Electr. connections
p. 416 f.
"V" U
Condensate discharges: None
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection:
Cable length 330 mm, beginning at wall ring
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
Brass lead tips
15
AC axial fans
130
Material:
Wall ring: Die-cast aluminium,
coated in black
Blades: Sheet steel, coated in black
Rotor: Open, coated in black
Number of blades: 5
Direction of air flow: "A", intake over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2S130-BM15-01 M2S 052-CA
p. 416 f.
B)
1~ 115 50 380 2700 47 60 -25 to +50
1~ 115 60 425 3050 46 62 -25 to +70
1~ 230 50 380 2700 47 60 -25 to +50
1~ 230 60 425 3050 46 62 -25 to +70
B
W2S130-BM03-01 M2S 052-CA B) 1.1
1.1
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
subject to alterations
100 200 300 400
0 50 100 150 [CFM] 200 250
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
0
,
4
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
B
Curves
Guard grille
p. 368 f.
Electr. connections
p. 416 f.
6 6
1
5
0

0
.
5
550.2
162
+0.15
-0.30
1720.5

4
,
4
5
-
0
.
0
5
/

4
,
2
0
+
0
.
0
5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"A"
Condensate discharges: None
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection:
Cable length 330 mm, beginning at wall ring
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
Brass lead tips
16
AC axial fans
142
Material:
Wall ring: Die-cast aluminium,
coated in black
Blades: Sheet steel, coated in black
Rotor: Open, coated in black
Number of blades: 7
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 22
Insulation class: "B"
Mounting position: Any
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2E 142-BB05 -01 M2E 052-BA
1~ 115 50 330 2800 25 52 -25 to +55
1~ 115 60 390 3300 24 57 -25 to +70
1~ 230 50 330 2800 25 52 -25 to +55
1~ 230 60 390 3300 24 57 -25 to +70
A
W2E 142-BB01 -01 M2E 052-BA 0.9
0.9
A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
100 200 300 400
0 50 100 200 [CFM] 150
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
A
Curves
Guard grille
p. 368 f.
Connection lead
p. 374
11 9
38+0,5
152,5
1620,2
1
5
0
+
0
,
5
172+0,5

4
,
2

0
,
1
80,1
"V" U Blade terminal 2.8 x 0.5 mm
Condensate discharges: None
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection: Blade terminal
2.8 x 0.5 mm (operating capacitor
connected)
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
17
AC axial fans
143
Material:
Wall ring: Die-cast aluminium,
coated in black
Blades: Sheet steel, coated in black
Rotor: Open, coated in black
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2E143 -AA15 -01 M2E 052-BF
1~ 115 50 375 2800 24 55 -25 to +70
1~ 115 60 440 3300 26 60 -25 to +70
1~ 230 50 375 2800 24 55 -25 to +70
1~ 230 60 440 3300 26 60 -25 to +70
B
W2E143 -AA09 -01 M2E 052-BF 1.0
1.0
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
100 200 300 400
0 50 100 150 [CFM] 200 250
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
B
Curves
Guard grille
p. 368 f.
Connection lead
p. 374
171,50,4
162
9
6

1
861
1
6
5

0
,
4
8
,
8
510,3

4
,
6

/

4
,
7
5
-
0
,
4
7
6

1
2
5

1
7,2
+0,1
-0,3
7,2
+0,1
-0,3
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" Blade terminal 2.8 x 0.5 mm
Condensate discharges: None
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection: Blade terminal
2.8 x 0.5 mm (operating capacitor
connected)
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
18
AC axial fans
143
Material:
Wall ring: Die-cast aluminium,
coated in black
Blades: Sheet steel, coated in black
Rotor: Open, coated in black
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2E 143-AB15 -01 M2E 052-BF
1~ 115 50 420 2800 26 54 -25 to +60
1~ 115 60 500 3300 29 58 -25 to +75
1~ 230 50 420 2800 26 54 -25 to +60
1~ 230 60 500 3300 29 58 -25 to +75
A
W2E 143-AB09 -01 M2E 052-BF 1.0
1.0
A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
100 200 300 400
0 50 100 150 [CFM] 200 250
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
A
Curves
Guard grille
p. 368 f.
Connection lead
p. 374
171,50,4
162
9
6

1
861
1
6
5

0
,
4
8
,
8
510,3

4
,
6

/

4
,
7
5
-
0
,
4
7
6

1
2
5

1
7,2
+0,1
-0,3
7,2
+0,1
-0,3
"V" Blade terminal 2.8 x 0.5 mm
Condensate discharges: None
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection: Blade terminal
2.8 x 0.5 mm (operating capacitor
connected)
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
19
AC axial fans
200
Material:
Wall ring: Die-cast aluminium
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2E 200-HK86 -01 M2E 068-BF
1~ 115 50 925 2550 64 0.58 5.0 /220 59 100 -25 to +60
1~ 115 60 1030 2800 80 0.70 5.0 /220 61 120 -25 to +65
1~ 230 50 925 2550 64 0.29 1.5 /400 59 100 -25 to +60
1~ 230 60 1030 2800 80 0.35 1.5 /400 61 120 -25 to +65
B
W2E 200-HK38 -01 M2E 068-BF 2.0
2.0
B
1~ 230 50 450 1370 30 0.21 40 50 -25 to +70
1~ 230 60 525 1590 26 0.18 44 50 -25 to +80
W4S200-HK04 -01 M4S 068-BF 2.0 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
200 400 600 800
0 100 300 400 [CFM] 200 500
[
P
a
]
20
40
60
80
100
120
140
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
B
C
Curves
Guard grille
p. 369
PE N L
(1)
ca. 2
260
240
4
,
5
+
0
,
2
2
2
5
1
2
7
2,6
4
800,3
240
260
2
2
5
4
,
5

+
0
,
2
1
2
4
N PE L
2,6
7
800,3
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
W2E200-HK
(1)
Protruding capacitor
W4S200-HK
"V" U
"V" U
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection: Terminal strips
(operating capacitor connected)
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC;
also GOST B
Capacitor
p. 382 f.
20
AC diagonal fans
208
Material:
Wall ring: Die-cast aluminium
Blades: Plastic PA
Rotor: Coated in black
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 44
Insulation class: "F"
Mounting position: Any
Condensate discharges: None
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2D208-BA02 -01 M2D068-CF
3~ 400 Y 50 820 2740 60 0.15 67 135 -25 to +70
3~ 400 Y 60 920 3090 80 0.15 70 165 -25 to +70
1~ 115 50 815 2750 67 0.70 6.0 /220 68 135 -25 to +72
1~ 115 60 925 3100 87 0.78 6.0 /220 70 165 -25 to +72
A
W2E 208-BA86 -01 M2E 068-CF 2.8
2.8
B
1~ 230 50 815 2750 67 0.33 1.5 /450 68 135 -25 to +72
1~ 230 60 925 3100 87 0.39 1.5 /450 70 165 -25 to +72
W2E 208-BA20 -01 M2E 068-CF 2.8 B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
200 400 600 800
0 100 300 400 [CFM] 200
[
P
a
]
20
40
60
80
100
120
140
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
500
B A
1
2
3
4
Curves
3090
2990
2960
2990
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]
80
93
96
92
70
69
69
70
A
A
A
A
1
2
4
3
3100
2990
2960
3020
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]
87
100
102
97
70
70
69
70
B
B
B
B
1
2
4
3
Capacitor
p. 382 f.
Guard grille
p. 367

4
,
5

4
,
5
10
0,3
10
0,3
"V" U
Section C-C
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Without TOP,
TOP wired internally
Electrical connection: Terminal strips
(operating capacitor connected)
Protection class: I
Product conforming to standards:
EN 60335-1, also CE
Approvals: VDE, CCC, GOST
B
B
A
21
AC axial fans
250
Material:
Wall ring: Die-cast aluminium
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 44
Insulation class: "F"
Mounting position: Any
Condensate discharges: None
Nominal data
Type Motor VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg
W2E 250-HL06 -01 M2E 068-CF
1~ 230 50 1865 2550 127 0.56 4.0 /400 69 100 -25 to +60
1~ 230 60 1970 2700 180 0.79 4.0 /400 70 100 -25 to +45
C 2.0
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
400 800 1200 1600
0 200 400 800 [CFM] 600
[
P
a
]
20
40
60
80
100
120
140
0
,
1
0
,
2
0
,
5
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
0
,
3
0
,
4
C
Curves
Capacitor
p. 382 f.
Guard grille
p. 369
PE N L
320
295

5
,
4
+
0
,
2
2
8
0
1
2
7
2,6
4
80
0,3
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" U
Mode of operation:
Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: TOP wired internally
Electrical connection: Terminal strips
(operating capacitor connected)
Protection class: I
Product conforming to standards:
EN 60335-1, CE
Approvals: VDE, UL, CSA, CCC, GOST
22
23
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
AC axial fans S series
AC axial fans, S series 500 - 910 74
AC axial fans, S series 200 - 450 24
24
AC axial fans
S series, 200
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 9
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 200
(1)
M2D068-BF
*2E 200 M2E 068-BF
*4D 200
(1)
M4D068-BF
subject to alterations
200 400 600 800
0 100 300 400 [CFM] 200 500
[
P
a
]
20
40
60
80
100
120
140
0
,
1
0
,
2
0
,
4
0
,
5
[
i
n

H
2 O
]
0
,
3
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
A
C
Curves
2540
2470
1430
1420
n
[rpm]
P
1
[W]
70
74
21
23
A
C
A
C
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 890 2600 68 0.29/0.17 65 140 -25 to +45
3~ 230/400 60 990 2900 70 0.23/0.13 68 140 -25 to +70
1~ 230 50 890 2600 64 0.30 1.5 /400 65 150 -25 to +70
1~ 230 60 990 2900 78 0.34 1.5 /400 68 150 -25 to +70
A
A1) 1.4
1.6
B
*4S 200 M4S 068-BF
1~ 230 50 470 1370 30 0.21 42 50 -25 to +75
1~ 230 60 540 1580 27 0.19 46 50 -25 to +80
B) 1.2 D
3~ 230/400 50 500 1440 20 0.12/0.07 43 70 -25 to +80
3~ 230/400 60 600 1690 20 0.10/0.06 47 90 -25 to +90
C1)/C2) 1.4 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.29/0.17
0.29/0.17
0.12/0.07
0.12/0.07
"V" A4S 200-AH04 -01
A4S 200-AI04 -01
W4S 200-CH04 -01
W4S 200-CI04 -01
S4S 200-BH04 -01
S4S 200-BI04 -01
S4S 200-AH04 -01
S4S 200-AI04 -01 "A"
25
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC B
D B
D B C A
D B C A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
(1)
With guard grille
for short nozzle
"V" A2D 200-AH18 -01
A2D 200-AI18 -01
W2D200-CH18 -01
W2D200-CI18 -01
S2D 200-BH18 -01
S2D 200-BI18 -01
S2D 200-AH18 -01
S2D 200-AI18 -01 "A"
"V" A2E 200-AH38 -01
A2E 200-AI38 -01
W2E 200-CH38 -01
W2E 200-CI38 -01
S2E 200-BH38 -01
S2E 200-BI38 -01
S2E 200-AH38 -01
S2E 200-AI38 -01 "A"
"V" A4D 200-AH14 -01
A4D 200-AI14 -01
W4D200-CH14 -01
W4D200-CI14 -01
S4D 200-BH14 -01
S4D 200-BI14 -01
S4D 200-AH14 -01
S4D 200-AI14 -01 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
200 400 600 800
0 100 300 400 [CFM] 200 500
[
P
a
]
20
40
60
80
100
120
140
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
D
B
D
B
D
2555
2465
1360
1350
67
70
31
31
0.31
0.32
0.22
0.22
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 26 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
(1) Increased noise levels in "V" direction of air flow
26
AC axial fans
S series, 200, drawings of directions of air flow "V" and "A"
9
0

58
2
7
M4
0,2
-
2

9
2

1
9
7
39
-
0
,
1

2
7
17
2
5
3 62
85
20
450
6
3
Without attachments
Type
A2D 200-AH18 -01
A2D 200-AI18 -01
A2E 200-AH38 -01
A2E 200-AI38 -01
A4D 200-AH14 -01
A4D 200-AI14 -01
A4S 200-AH04 -01
A4S 200-AI04 -01
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
5
7
6
x
6
0

250

2
8
0

2
0
0
80
1
5

1
,
2
5
9
With full round nozzle
Type
W2D200-CH18 -01
W2D200-CI18 -01
W2E 200-CH38 -01
W2E 200-CI38 -01
W4D200-CH14 -01
W4D200-CI14 -01
W4S 200-CH04 -01
W4S 200-CI04 -01
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
4,5
2
4
5
3,9
With guard grille for full nozzle
Type
S2D 200-BH18 -01
S2D 200-BI18 -01
S2E 200-BH38 -01
S2E 200-BI38 -01
S4D 200-BH14 -01
S4D 200-BI14 -01
S4S 200-BH04 -01
S4S 200-BI04 -01
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
27
46
3,9
23
5 13 7
2
6
0
2
2
9
With guard grille for short nozzle
Type
S2D 200-AH18 -01
S2D 200-AI18 -01
S2E 200-AH38 -01
S2E 200-AI38 -01
S4D 200-AH14 -01
S4D 200-AI14 -01
S4S 200-AH04 -01
S4S 200-AI04 -01
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l
i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
28
AC axial fans
S series, 250
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 250
(1)
M2D068-CF
*2E 250 M2E 068-CF
*4D 250
(1)
M4D068-CF
subject to alterations
400 800 1200 1600
0 200 400 800 [CFM] 600
[
P
a
]
20
40
60
80
100
120
140
0
,
1
0
,
2
0
,
5
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
0
,
3
0
,
4
2
2
1
1
A
D
E
Curves
2455
2310
1370
1360
1370
1360
n
[rpm]
P
1
[W]
106
125
43
45
71
73
A
D
E
A
D
E
1
2
2
2
1
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 1830 2500 100 0.34/0.20 69 150 -25 to +65
3~ 230/400 60 1950 2650 140 0.40/0.23 70 150 -25 to +45
1~ 230 50 1820 2450 115 0.51 3.0 /400 69 120 -25 to +65
1~ 230 60 1970 2600 150 0.66 3.0 /400 71 85 -25 to +50
A
A1) 1.9
2.1
B
3~ 230/400 50 1010 1400 25 0.12/0.07 54 70 -25 to +85
3~ 230/400 60 1140 1580 32 0.12/0.07 57 70 -25 to +80
C1)/C2) 1.9 C
*4E 250 M4E 068-BF
1~ 230 50 1010 1400 42 0.19 1.5 /400 54 80 -25 to +55
1~ 230 60 1200 1630 45 0.20 1.5 /400 58 100 -25 to +70
A1) 1.9 D
*4S 250 M4S 068-CF
1~ 230 50 1000 1390 69 0.53 54 80 -25 to +50
1~ 230 60 1160 1600 63 0.45 58 80 -25 to +65
B) 1.7 E
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.34/0.20
0.38/0.22
0.20
0.20
0.53
0.53
29
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC; also GOST D D B A
E D B
D B E C A
E D B C A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
(1)
With guard grille
for short nozzle
"V" A2D 250-AH02 -01
A2D 250-AI02 -01
W2D250-CH02 -01
W2D250-CI02 -01
S2D 250-BH02 -01
S2D 250-BI02 -01
S2D 250-AH02 -01
S2D 250-AI02 -01 "A"
"V" A2E 250-AL06 -01
A2E 250-AM06 -01
W2E 250-CL06 -01
W2E 250-CM06 -01
S2E 250-BL06 -01
S2E 250-BM06 -01
S2E 250-AL06 -01
S2E 250-AM06 -01 "A"
"V" A4D 250-AH22 -01
A4D 250-AI22 -01
W4D250-CH22 -01
W4D250-CI22 -01
S4D 250-BH22 -01
S4D 250-BI22 -01
S4D 250-AH22 -01
S4D 250-AI22 -01 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
400 800 1200 1600
0 200 600 800 [CFM] 400
[
P
a
]
20
40
60
80
100
120
140
0
,
1
0
,
2
0
,
3
0
,
5
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
C
B
C
B
C
2455
2290
1375
1350
116
132
27
30
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 30 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4E 250-AH02 -01
A4E 250-AI02 -01
W4E 250-CH02 -01
W4E 250-CI02 -01
S4E 250-BH02 -01
S4E 250-BI02 -01
S4E 250-AH02 -01
S4E 250-AI02 -01 "A"
"V" A4S 250-AH02 -01
A4S 250-AI02 -01
W4S 250-CH02 -01
W4S 250-CI02 -01
S4S 250-BH02 -01
S4S 250-BI02 -01
S4S 250-AH02 -01
S4S 250-AI02 -01 "A"
(1) Increased noise levels in "V" direction of air flow
I
[A]
0.51
0.57
0.12/0.07
0.12/0.07
30
AC axial fans
S series, 250, drawings of directions of air flow "V" and "A"
9
0

58
2
7
M4
0,2
-
2

9
2

2
5
1
34
-
0
,
1

2
7
c
2
5
3 a
85
20
450
6
3
Without attachments
Type
a c
A2D 250-AH02 -01
A2D 250-AI02 -01
A2E 250-AL06 -01
A2E 250-AM06 -01
A4D 250-AH22 -01
A4D 250-AI22 -01
A4E 250-AH02 -01
A4E 250-AI02 -01
A4S 250-AH02 -01
A4S 250-AI02 -01
72.0
72.0
72.0
72.0
72.0
72.0
62.0
62.0
72.0
72.0
18.0
21.0
18.0
27.0
18.0
27.0
14.0
22.0
18.0
23.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
6
7
6
x
6
0

2
9
5

3
2
0

2
5
7
87
1
5

1
,
2
5
9
With full round nozzle
Type
W2D250-CH02 -01
W2D250-CI02 -01
W2E 250-CL06 -01
W2E 250-CM06 -01
W4D250-CH22 -01
W4D250-CI22 -01
W4E 250-CH02 -01
W4E 250-CI02 -01
W4S 250-CH02 -01
W4S 250-CI02 -01
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
4,5
2
9
0
3,9
h
k
With guard grille for full nozzle
Type
h k
S2D 250-BH02 -01
S2D 250-BI02 -01
S2E 250-BL06 -01
S2E 250-BM06 -01
S4D 250-BH22 -01
S4D 250-BI22 -01
S4E 250-BH02 -01
S4E 250-BI02 -01
S4S 250-BH02 -01
S4S 250-BI02 -01
5.0
0
5.0
0
5.0
0
5.0
0
5.0
0
10.0
0
10.0
0
10.0
0
10.0
0
10.0
0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
31
m
3,9
7
3
0
0
2
7
1
n
v
u
With guard grille for short nozzle
Type
m n
S2D 250-AH02 -01
S2D 250-AI02 -01
S2E 250-AL06 -01
S2E 250-AM06 -01
S4D 250-AH22 -01
S4D 250-AI22 -01
S4E 250-AH02 -01
S4E 250-AI02 -01
S4S 250-AH02 -01
S4S 250-AI02 -01
50.0
45.0
50.0
45.0
50.0
45.0
50.0
45.0
50.0
45.0
5.0
0
5.0
0
5.0
0
5.0
0
5.0
0
u v
14.0
17.0
14.0
23.0
14.0
23.0
10.0
18.0
14.0
19.0
34.0
34.0
34.0
34.0
34.0
34.0
24.0
24.0
34.0
34.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
32
AC axial fans 2-pole
S series, 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 300
(1)
M2D074-DF
*2E 300 M2E 074-DF
subject to alterations
1000 2000 3000
0 500 1000 2000 [CFM] 1500
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
2530
2400
n
[rpm]
P
1
[W]
228
273
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 3130 2580 210 0.62/0.36 72 200 -25 to +55
3~ 230/400 60 3350 2750 300 0.83/0.48 73 125 -25 to +40
1~ 230 50 3410 2700 230 1.10 8.0 /400 73 200 -25 to +50
1~ 230 60 3740 3000 350 1.55 8.0 /400 76 50 -25 to +40
A
A1) 3.0
3.0
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.68/0.39
0.78/0.45
33
Motor protection: Without TOP, TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC
B
B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A2D 300-AP02 -01
A2D 300-AP02 -02
W2D300-CP02 -30
W2D300-CP02 -31
S2D 300-BP02 -30
S2D 300-BP02 -31
S2D 300-AP02 -30
S2D 300-AP02 -31 "A"
"V" A2E 300-AP02 -01
A2E 300-AP02 -02
W2E 300-CP02 -30
W2E 300-CP02 -31
S2E 300-BP02 -30
S2E 300-BP02 -31
S2E 300-AP02 -30
S2E 300-AP02 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
B
1000 2000 3000
0 500 1500 [CFM] 1000 2000
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
1
2
B
B
2680
2560
252
290
1.11
1.27
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 34 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
34
AC axial fans 2-pole
S series, 300, drawings of directions of air flow "V" and "A"
+
104
6
85
450
20

7
5
5
30
3
0 -
2
90
0,2

1
0
2

2
9
8

2
3
7
38
3
M4
M6
4
x
9
0

Without attachments
Type
A2D 300-AP02 -01
A2D 300-AP02 -02
A2E 300-AP02 -01
A2E 300-AP02 -02
"V"
"A"
"V"
"A"
0
3
8
0

3
2
6

3
9
7
11
80
6
x
6
0

9
1
5

With full round nozzle


Type
W2D300-CP02 -30
W2D300-CP02 -31
W2E 300-CP02 -30
W2E 300-CP02 -31
"V"
"A"
"V"
"A"
3
6
0
5
0
6,5
With guard grille for full nozzle
Type
S2D 300-BP02 -30
S2D 300-BP02 -31
S2E 300-BP02 -30
S2E 300-BP02 -31
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 10 mm
Brass lead tips
35
50
5
0
3
6
0
6,5
18
54
3
2
4
With guard grille for short nozzle
Type
S2D 300-AP02 -30
S2D 300-AP02 -31
S2E 300-AP02 -30
S2E 300-AP02 -31
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
36
AC axial fans 4-pole
S series, 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 300
(1)
M4D068-CF
*4E 300 M4E 068-CF
subject to alterations
500 1000 1500
0 250 500 1000 [CFM] 750
[
P
a
]
20
40
60
80
100
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
1
2
A
Curves
1350
1260
n
[rpm]
P
1
[W]
66
88
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 1860 1370 60 0.29/0.17 57 90 -25 to +45
3~ 230/400 60 2080 1540 75 0.26/0.15 60 60 -25 to +40
1~ 230 50 1740 1400 68 0.30 2.0 /400 59 80 -25 to +60
1~ 230 60 2040 1630 92 0.41 2.0 /400 63 70 -25 to +45
A
A1) 1.9
1.9
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.29/0.17
0.33/0.19
37
Motor protection: Without TOP, TOP wired internally
Cable exit: Axial, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC; also GOST B
B
B A
B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 300-AP28 -01
A4D 300-AP28 -02
W4D300-CP28 -30
W4D300-CP28 -31
S4D 300-BP28 -30
S4D 300-BP28 -31
S4D 300-AP28 -30
S4D 300-AP28 -31 "A"
"V" A4E 300-AP26 -01
A4E 300-AP26 -02
W4E 300-CP26 -30
W4E 300-CP26 -31
S4E 300-BP26 -30
S4E 300-BP26 -31
S4E 300-AP26 -30
S4E 300-AP26 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
500 1000 1500
0 250 500 1000 [CFM] 750
[
P
a
]
20
40
60
80
100
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
1
2
B
B
B
1390
1290
72
88
0.32
0.39
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 38 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
38
AC axial fans 4-pole
S series, 300, drawings of directions of air flow "V" and "A"
+
73
6
85
450
20

2
7
2
c3
0 -
2
58
0,2

9
2

3
0
0
-
2
2
7
603
M4
M4
4
x
9
0

Without attachments
Type
c
A4D 300-AP28 -01
A4D 300-AP28 -02
A4E 300-AP26 -01
A4E 300-AP26 -02
13.0
-7.0
13.0
-7.0
"V"
"A"
"V"
"A"
k
3
8
0

3
2
6

3
9
7
11
80
6
x
6
0

9
1
5

With full round nozzle


Type
k
W4D300-CP28 -30
W4D300-CP28 -31
W4E 300-CP26 -30
W4E 300-CP26 -31
0.0
30.0
0.0
30.0
"V"
"A"
"V"
"A"
3
6
0
4
k
4,5
With guard grille for full nozzle
Type
k
S4D 300-BP28 -30
S4D 300-BP28 -31
S4E 300-BP26 -30
S4E 300-BP26 -31
0.0
30.0
0.0
30.0
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
39
50
4
k
3
6
0
4,5
3
2
9
,
5
u
v
With guard grille for short nozzle
Type
k
S4D 300-AP28 -30
S4D 300-AP28 -31
S4E 300-AP26 -30
S4E 300-AP26 -31
0.0
30.0
0.0
30.0
u
23.0
29.0
23.0
29.0
v
23.0
49.0
23.0
49.0
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
40
AC axial fans
S series, 315
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 315
(1)
M4D068-DF
*4E 315 M4E 068-DF
*6E 315 M6E 068-DF
subject to alterations
600 1200 1800 2400
0 250 1000 1250 [CFM] 500 750 1500
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
4
[
i
n

H
2 O
]
0
,
3
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1400
1380
n
[rpm]
P
1
[W]
90
103
A
A
1
2
Drawings
p. 42 f.
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 2450 1400 85 0.45/0.26 60 120 -25 to +55
3~ 230/400 60 2810 1620 110 0.42/0.24 64 120 -25 to +55
1~ 230 50 2440 1410 102 0.52 4.0 /400 59 120 -25 to +55
1~ 230 60 2840 1650 120 0.53 4.0 /400 64 120 -25 to +55
A
A1) 2.4
2.4
B
1~ 230 50 1650 950 65 0.33 2.0 /400 51 70 -25 to +50
1~ 230 60 1950 1120 68 0.30 2.0 /450 55 80 -25 to +60
A1) 2.4 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.45/0.26
0.47/0.27
41
Motor protection: Without TOP, TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC; also GOST A
C B
C B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 315-AP10 -01
A4D 315-AP10 -02
W4D315-CP10 -30
W4D315-CP10 -31
S4D 315-BP10 -30
S4D 315-BP10 -31
S4D 315-AP10 -30
S4D 315-AP10 -31 "A"
"V" A4E 315-AP18 -01
A4E 315-AP18 -02
W4E 315-CP18 -30
W4E 315-CP18 -31
S4E 315-BP18 -30
S4E 315-BP18 -31
S4E 315-AP18 -30
S4E 315-AP18 -31 "A"
"V" A6E 315-AP02 -01
A6E 315-AP02 -02
W6E 315-CP02 -30
W6E 315-CP02 -31
S6E 315-BP02 -30
S6E 315-BP02 -31
S6E 315-AP02 -30
S6E 315-AP02 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
600 1200 1800 2400
0 250 1000 1250 [CFM] 500 750 1500
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
C
B
C
B
C
1400
1380
945
930
108
120
63
66
0.54
0.57
0.33
0.33
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
In-line duct fan
W4D315-IP10 -01

W4E 315-IP18 -01

"V"
Terminal box
p. 381
Wall ring
p. 372 f.
Streamer
p. 371
Guard grille
p. 362 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
42
AC axial fans
S series, 315, drawings of directions of air flow "V" and "A"
83
+
85
20
450
85
2

2
7
6
- 0
3 c
2 0,2
58
M4

3
1
2

9
2
2
7
M4
4
x
9
0

Without attachments
Type
c
A4D 315-AP10 -01
A4D 315-AP10 -02
A4E 315-AP18 -01
A4E 315-AP18 -02
A6E 315-AP02 -01
A6E 315-AP02 -02
5.0
-7.0
5.0
-7.0
5.0
-7.0
"V"
"A"
"V"
"A"
"V"
"A"
33

3
9
7

3
4
7
74
11
3
8
0
9
6
x
6
0

1
5

With full round nozzle


Type
W4D315-CP10 -30
W4D315-CP10 -31
W4E 315-CP18 -30
W4E 315-CP18 -31
W6E 315-CP02 -30
W6E 315-CP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
4,5
30
3
7
5
6,5
With guard grille for full nozzle
Type
S4D 315-BP10 -30
S4D 315-BP10 -31
S4E 315-BP18 -30
S4E 315-BP18 -31
S6E 315-BP02 -30
S6E 315-BP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
43
30
80
4,5
3
7
5
6,5
3
3
6
,
5
u
33
With guard grille for short nozzle
Type
S4D 315-AP10 -30
S4D 315-AP10 -31
S4E 315-AP18 -30
S4E 315-AP18 -31
S6E 315-AP02 -30
S6E 315-AP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
In-line duct fan
Type
W4D315-IP10 -01
W4E 315-IP18 -01
"V"
"V"
"V"
u
40.0
28.0
40.0
28.0
40.0
28.0
44
AC axial fans
S series, 330
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 330
(1)
M4D068-DF
*4E 330 M4E 068-DF
*6E 330 M6E 068-DF
subject to alterations
500 1000 1500 2000 2500 3000
0 500 1000 1500 [CFM]
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
0
,
5
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1370
1325
n
[rpm]
P
1
[W]
102
126
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 2800 1390 100 0.45/0.26 59 120 -25 to +55
3~ 230/400 60 3180 1570 130 0.42/0.24 63 120 -25 to +45
1~ 230 50 2830 1390 120 0.57 4.0 /400 63 90 -25 to +50
1~ 230 60 3230 1600 140 0.60 4.0 /400 67 75 -25 to +40
A
A1) 2.5
2.6
B
1~ 230 50 1940 940 65 0.33 2.0 /400 49 60 -25 to +50
1~ 230 60 2280 1100 72 0.32 2.0 /450 53 70 -25 to +65
A1) 2.5 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.45/0.26
0.48/0.28
45
Motor protection: Without TOP, TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC C B
C B
C B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 330-AP10 -01
A4D 330-AP10 -02
W4D330-CP10 -30
W4D330-CP10 -31
S4D 330-BP10 -30
S4D 330-BP10 -31
S4D 330-AP10 -30
S4D 330-AP10 -31 "A"
"V" A4E 330-AP18 -01
A4E 330-AP18 -02
W4E 330-CP18 -30
W4E 330-CP18 -31
S4E 330-BP18 -30
S4E 330-BP18 -31
S4E 330-AP18 -30
S4E 330-AP18 -31 "A"
"V" A6E 330-AP02 -01
A6E 330-AP02 -02
W6E 330-CP02 -30
W6E 330-CP02 -31
S6E 330-BP02 -30
S6E 330-BP02 -31
S6E 330-AP02 -30
S6E 330-AP02 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
500 1000 1500 2000 2500 3000
0 500 1000 1500 [CFM]
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
0
,
5
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
C
B
C
B
C
1375
1325
925
910
122
140
68
70
0.58
0.64
0.34
0.35
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 46 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
46
AC axial fans
S series, 330, drawings of directions of air flow "V" and "A"
2
20
85
450

2
7
6
83
3
2
c
87
M4

9
2
2

3
3
0
2
7
0,2
58
- 0 +
M4
4
x
9
0

Without attachments
Type
c
A4D 330-AP10 -01
A4D 330-AP10 -02
A4E 330-AP18 -01
A4E 330-AP18 -02
A6E 330-AP02 -01
A6E 330-AP02 -02
6.0
-8.0
6.0
-8.0
6.0
-8.0
"V"
"A"
"V"
"A"
"V"
"A"
30

4
4
0

3
6
9
80
11
4
0
4
6
x
6
0

9
1
5

With full round nozzle


Type
W4D330-CP10 -30
W4D330-CP10 -31
W4E 330-CP18 -30
W4E 330-CP18 -31
W6E 330-CP02 -30
W6E 330-CP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
30
4,5
4
1
0
6,5
With guard grille for full nozzle
Type
S4D 330-BP10 -30
S4D 330-BP10 -31
S4E 330-BP18 -30
S4E 330-BP18 -31
S6E 330-BP02 -30
S6E 330-BP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
47
30
4
1
0
4,5
80
6,5
3
5
4
,
5
u
33
With guard grille for short nozzle
Type
S4D 330-AP10 -30
S4D 330-AP10 -31
S4E 330-AP18 -30
S4E 330-AP18 -31
S6E 330-AP02 -30
S6E 330-AP02 -31
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
u
43.0
29.0
43.0
29.0
43.0
29.0
48
AC axial fans
S series, 350
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B", "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
B C A
Nominal data
Type Motor
*4D 350
(1)
M4D068-EC
*4E 350 M4E 068-EC
*6E 350 M6E 068-DF
subject to alterations
1000 2000 3000
0 500 1000 1500 [CFM] 2000
[
P
a
]
40
80
120
160
0
,
2
0
,
6
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1400
1380
n
[rpm]
P
1
[W]
150
173
A
A
1
2
Drawings
p. 50 f.
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 3340 1420 135 0.73/0.42 64 120 -25 to +60
3~ 230/400 60 3815 1620 185 0.64/0.37 68 145 -25 to +45
1~ 230 50 3250 1365 132 0.58 5.0 /400 64 90 -25 to +60
1~ 230 60 3640 1530 180 0.80 5.0 /400 67 65 -25 to +50
A
A1) 3.6
3.6
B
1~ 230 50 2110 905 60 0.27 2.5 /400 55 40 -25 to +60
1~ 230 60 2420 1040 85 0.38 2.5 /400 58 45 -25 to +55
A1) 3.6 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
I
[A]
0.75/0.43
0.75/0.43
49
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, axial
Protection class: I
Product conforming to standards: EN 60335-1, also CE C B
C B A
C B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 350-AR06 -01
A4D 350-AR06 -02
W4D350-CR06 -30
W4D350-CR06 -31
S4D 350-BR06 -30
S4D 350-BR06 -31
S4D 350-AR06 -30
S4D 350-AR06 -31 "A"
"V" A4E 350-AR06 -01
A4E 350-AR06 -02
W4E 350-CR06 -30
W4E 350-CR06 -31
S4E 350-BR06 -30
S4E 350-BR06 -31
S4E 350-AR06 -30
S4E 350-AR06 -31 "A"
"V" A6E 350-AR08 -01
A6E 350-AR08 -02
W6E 350-CR08 -30
W6E 350-CR08 -31
S6E 350-BR08 -30
S6E 350-BR08 -31
S6E 350-AR08 -30
S6E 350-AR08 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000
0 500 1000 2000 [CFM] 1500
[
P
a
]
20
40
60
80
100
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
C
B
C
B
C
1335
1260
880
825
142
166
63
68
0.63
0.74
0.28
0.30
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Streamer
p. 371
Guard grille
p. 362 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
W4D350-IR06 -01

W4E 350-IR06 -01

"V"
50
AC axial fans
S series, 350, drawings of directions of air flow "V" and "A"
2
a
0,2
58
85
20
600
6

2
7
3
2
c
-
92
0
3
+
M4

3
5
2

9
2
2
7
M4
4
x
9
0

Without attachments
Type
a c
A4D 350-AR06 -01
A4D 350-AR06 -02
A4E 350-AR06 -01
A4E 350-AR06 -02
A6E 350-AR08 -01
A6E 350-AR08 -02
102.0
102.0
102.0
102.0
83.0
83.0
10.0
-10.0
10.0
-10.0
5.0
-12.0
"V"
"A"
"V"
"A"
"V"
"A"
30
12
80

3
9
0

4
6
0
4
4
2
6
x
6
0

9
1
5

With full round nozzle


Type
W4D350-CR06 -30
W4D350-CR06 -31
W4E 350-CR06 -30
W4E 350-CR06 -31
W6E 350-CR08 -30
W6E 350-CR08 -31
"V"
"A"
"V"
"A"
"V"
"A"
30
4,5
6,5
4
2
2
With guard grille for full nozzle
Type
S4D 350-BR06 -30
S4D 350-BR06 -31
S4E 350-BR06 -30
S4E 350-BR06 -31
S6E 350-BR08 -30
S6E 350-BR08 -31
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
51
4,5
30
80
6,5
4
2
2
3
7
4
u
v
With guard grille for short nozzle
Type
S4D 350-AR06 -30
S4D 350-AR06 -31
S4E 350-AR06 -30
S4E 350-AR06 -31
S6E 350-AR08 -30
S6E 350-AR08 -31
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
In-line duct fan
Type
W4D350-IR06 -01
W4E 350-IR06 -01
"V"
"V"
"V"
u
52.0
32.0
52.0
32.0
47.0
30.0
v
52.0
52.0
52.0
52.0
33.0
33.0
52
AC axial fans
S series, 400
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B", "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
C B A
Nominal data
Type Motor
*4D 400
(1)(2)
M4D074-EI
*4E 400 M4E 074-EI
*6E 400 M6E 074-DF
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM] 1500 2000 2500
[
P
a
]
40
80
120
160
0
,
2
0
,
6
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1440
1415
n
[rpm]
P
1
[W]
152
195
A
A
1
2
Drawings
p. 54 f.
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 4000 1450 135 0.76/0.44 68 150 -25 to +40
3~ 230/400 60 4610 1690 185 0.68/0.39 72 120 -25 to +40
1~ 230 50 4235 1430 160 0.73 6.0 /400 69 150 -25 to +40
1~ 230 60 4950 1700 240 1.06 6.0 /400 73 75 -25 to +40
A
A1) 4.2
4.2
B
1~ 230 50 3290 940 120 0.55 3.0 /450 59 50 -25 to +40
1~ 230 60 3780 1080 170 0.75 3.0 /400 62 40 -25 to +60
A1) 4.0 C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 400 VAC /Y for two speed steps available on request (2) 230 VAC / 400 VAC Y
I
[A]
0.82/0.47
0.86/0.50
53
Motor protection: Without TOP, TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC
Options: Terminal box
C B
C B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 400-AP12 -01
A4D 400-AP12 -02
W4D400-CP12 -30
W4D400-CP12 -31
S4D 400-BP12 -30
S4D 400-BP12 -31
S4D 400-AP12 -03
S4D 400-AP12 -04 "A"
"V" A4E 400-AP02 -01
A4E 400-AP02 -02
W4E 400-CP02 -30
W4E 400-CP02 -31
S4E 400-BP02 -30
S4E 400-BP02 -31
S4E 400-AP02 -03
S4E 400-AP02 -04 "A"
"V" A6E 400-AP10 -01
A6E 400-AP10 -02
W6E 400-CP10 -30
W6E 400-CP10 -31
S6E 400-BP10 -30
S6E 400-BP10 -31
S6E 400-AP10 -30
S6E 400-AP10 -31 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000
0 500 1500 2000 [CFM] 1000 2500
[
P
a
]
40
80
120
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
2
1
1
B
C
B
C
B
C
1430
1395
935
895
172
210
126
140
0.78
0.93
0.57
0.62
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Streamer
p. 371
Guard grille
p. 362 ff.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
W4D400-IP12 -01

W4E 400-IP02 -01

"V"
54
AC axial fans
S series, 400, drawings of directions of air flow "V" and "A"
3
2
20
85
600
a
6

7
5
5
3 c
-
p
0 +

3
9
2

1
0
2
0,2
90
3
7
M4
M6
4
x
9
0

Without attachments
Type
a c p
A4D 400-AP12 -01
A4D 400-AP12 -02
A4E 400-AP02 -01
A4E 400-AP02 -02
A6E 400-AP10 -01
A6E 400-AP10 -02
117.0
117.0
117.0
117.0
104.0
104.0
26.0
22.0
26.0
22.0
-5.0
14.0
68.0
68.0
68.0
68.0
90.0
88.0
"V"
"A"
"V"
"A"
"V"
"A"
30

5
2
8

4
1
9
12
96
5
0
4
6
x
6
0

9
1
5

With full round nozzle


Type
W4D400-CP12 -30
W4D400-CP12 -31
W4E 400-CP02 -30
W4E 400-CP02 -31
W6E 400-CP10 -30
W6E 400-CP10 -31
"V"
"A"
"V"
"A"
"V"
"A"
30
5
5
0
2
9
With guard grille for full nozzle
Type
S4D 400-BP12 -30
S4D 400-BP12 -31
S4E 400-BP02 -30
S4E 400-BP02 -31
S6E 400-BP10 -30
S6E 400-BP10 -31
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 10 mm
Brass lead tips
55
k
80
5
9
4
7
0
f
u
v
With guard grille for short nozzle
Type
f
S4D 400-AP12 -03
S4D 400-AP12 -04
S4E 400-AP02 -03
S4E 400-AP02 -04
S6E 400-AP10 -30
S6E 400-AP10 -31
420.0
420.0
420.0
420.0
414.0
414.0
k
10.0
10.0
10.0
10.0
30.0
30.0
u
24.0
20.0
24.0
20.0
35.0
52.0
v
47.0
47.0
47.0
47.0
54.0
54.0
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
In-line duct fan
Type
W4D400-IP12 -01
W4E 400-IP02 -01
"V"
"V"
"V"
VAC Hz rpm W A F/VDB Pa C kg
3~ 400 50 1360 260 0.52 95 -40 to +60
3~ 400 Y 50 1060 185 0.31 60 -40 to +60
3~ 400 60 1490 385 0.65 110 -40 to +60
3~ 400 Y 60 970 220 0.37 47 -40 to +60
1~ 230 50 1360 280 1.25 7.0 /400 95 -40 to +60
1~ 230 60 1520 385 1.68 7.0 /400 100 -40 to +60
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
56
AC axial fans
S series, 420
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Plastic, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 420 M4D094-EA
*4E 420 M4E 094-EA
subject to alterations
1000 2000 3000 4000 5000
0 1000 2000 3000 [CFM]
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
0
,
4
1
1
2
2
D
A
C
B
Curves
1380
1360
1120
1060
n
[rpm]
P
1
[W]
I
[A]
225
260
170
185
0.47
0.52
0.29
0.31
A
B
A
B
1
2
2
1
p. 416 f.
F1b)/F2b)
A
B
C
D
F1b)/F2b) 5.8
5.8
A2b) 5.8 E
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load
Lp
A
[dB(A)]
67
65
61
58
57
Motor protection: - Design with thermal overload protector, TOP wired internally
Cable exit: Lateral via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
E D A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 420-AU02 -01
A4D 420-AU02 -02
W4D420-CU02 -30
W4D420-CU02 -31
S4D 420-BU02 -30
S4D 420-BU02 -31
S4D 420-AU02 -03
S4D 420-AU02 -04 "A"
"V" A4E 420-AU03 -01
A4E 420-AU03 -02
W4E 420-CU03 -30
W4E 420-CU03 -31
S4E 420-BU03 -30
S4E 420-BU03 -31
S4E 420-AU03 -03
S4E 420-AU03 -04 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000 5000
0 1000 2000 3000 [CFM]
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
0
,
4
E
1
2
E
E
1390
1360
247
280
1.13
1.25
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 58 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
67
65
Lp
A
[dB(A)]
58
AC axial fans
S series, 420, drawings of directions of air flow "V" and "A"
Without attachments
Type
b
A4D 420-AU02 -01
A4D 420-AU02 -02
A4E 420-AU03 -01
A4E 420-AU03 -02
89
89
99x99
99x99
c
1
2.0
16.0
2.0
16.0
h
33.5
33.5
59.5
59.5
"V"
"A"
"V"
"A"
With full round nozzle
Type
W4D420-CU02 -30
W4D420-CU02 -31
W4E 420-CU03 -30
W4E 420-CU03 -31
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
c
2
S4D 420-BU02 -30
S4D 420-BU02 -31
S4E 420-BU03 -30
S4E 420-BU03 -31
77.5
91.5
77.5
91.5
"V"
"A"
"V"
"A"
Depth of screw
max. 10 mm
Cable gland
"V"
"A" U
"V"
"A" U
"V"
"A" U
59
With guard grille for short nozzle
Type
c
3
S4D 420-AU02 -03
S4D 420-AU02 -04
S4E 420-AU03 -03
S4E 420-AU03 -04
47.5
61.5
47.5
61.5
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
60
AC axial fans 6-pole
S series, 420 / 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6E 420 M6E 074-EI
*6E 450 M6E 074-GA
subject to alterations
1000 2000 3000 4000 5000
0 1000 2000 3000 [CFM]
[
P
a
]
40
80
120
160
0
,
2
0
,
6
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
930
890
n
[rpm]
P
1
[W]
I
[A]
155
176
0.71
0.80
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 3940 940 145 0.67 4.0 /450 60 90 -25 to +50
1~ 230 60 4570 1090 205 0.90 4.0 /450 63 80 -25 to +45
1~ 230 50 4725 940 165 0.80 4.0 /450 63 70 -25 to +40
1~ 230 60 5450 1070 225 0.98 4.0 /450 67 45 -25 to +40
A
A1) 5.0
4.4
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
61
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Options: Terminal box
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A6E 420-AP02 -01
A6E 420-AP02 -02
W6E 420-CP02 -30
W6E 420-CP02 -31
S6E 420-BP02 -30
S6E 420-BP02 -31
S6E 420-AP02 -30
S6E 420-AP02 -31 "A"
"V" A6E 450-AP02 -01
A6E 450-AP02 -02
W6E 450-CP02 -01
W6E 450-CP02 -02
S6E 450-BP02 -01
S6E 450-BP02 -02
S6E 450-AP02 -01
S6E 450-AP02 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000 5000 6000
0 1000 2000 [CFM] 3000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
B
B
B
930
870
171
200
0.82
0.94
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 362 ff.
Drawings
p. 62 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
62
AC axial fans
S series, 420 / 450, drawings of directions of air flow "V" and "A"
0,2
600

7
5
20
85
6
5
3
c
90 a

1
0
2

2
2

b
3
p
3
7
M4
- 0 +
M6
4
x
9
0

Without attachments
Type
a b c p
A6E 420-AP02 -01
A6E 420-AP02 -02
A6E 450-AP02 -01
A6E 450-AP02 -02
117.0
117.0
129.0
129.0
418.0
418.0
446.0
446.0
2.0
21.0
10.0
25.0
89.0
89.0
92.0
92.0
"V"
"A"
"V"
"A"
30

x
u
v
t
6
x
6
0

s
1
5

With full round nozzle


Type
s t u v w x
W6E 420-CP02 -30
W6E 420-CP02 -31
W6E 450-CP02 -01
W6E 450-CP02 -02
9.0
9.0
11.0
11.0
520.0
520.0
578.0
578.0
96.0
96.0
100.0
100.0
12.0
12.0
14.0
14.0
447.0
447.0
465.0
465.0
544.0
544.0
607.0
607.0
"V"
"A"
"V"
"A"
5
30
r
9
With guard grille for full nozzle
Type
r
S6E 420-BP02 -30
S6E 420-BP02 -31
S6E 450-BP02 -01
S6E 450-BP02 -02
502.0
502.0
522.0
522.0
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 10 mm
Brass lead tips
63
30
r
5
80
9
f
u
v
With guard grille for short nozzle
Type
f
S6E 420-AP02 -30
S6E 420-AP02 -31
S6E 450-AP02 -01
S6E 450-AP02 -02
452.0
452.0
476.0
476.0
r
502.0
502.0
522.0
522.0
u
41.0
60.0
52.0
67.0
v
67.0
67.0
79.0
79.0
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
VAC Hz rpm W A F/VDB Pa C kg
3~ 400 50 1250 340 0.61 120 -40 to +60
3~ 400 Y 50 875 200 0.33 60 -40 to +60
3~ 400 60 1360 415 0.70 85 -40 to +50
3~ 400 Y 60 860 205 0.35 35 -40 to +50
1~ 230 50 1300 350 1.55 8.0 /400 120 -40 to +55
1~ 230 60 1490 425 1.87 8.0 /400 50 -40 to +45
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
64
AC axial fans
S series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Plastic, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 450 M4D094-EA
*4E 450 M4E 094-EA
subject to alterations
1000 2000 3000 4000 5000 6000
0 1000 2000 [CFM] 2000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
1
1
2
2
A
B
C
D
Curves
1300
1250
985
875
n
[rpm]
P
1
[W]
I
[A]
285
340
180
200
0.54
0.61
0.30
0.33
A
B
A
B
1
2
2
1
p. 416 f.
F1b)/F2b)
A
B
C
D
F1b)/F2b) 6.0
6.0
A2b) 6.0 E
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load
Lp
A
[dB(A)]
67
64
59
54
65
Motor protection: - Design with thermal overload protector, TOP wired internally
Cable exit: Lateral via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
E D A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 450-AU01 -01
A4D 450-AU01 -02
W4D450-CU01 -01
W4D450-CU01 -02
S4D 450-BU01 -01
S4D 450-BU01 -02
S4D 450-AU01 -01
S4D 450-AU01 -02 "A"
"V" A4E 450-AU03 -01
A4E 450-AU03 -02
W4E 450-CU03 -01
W4E 450-CU03 -02
S4E 450-BU03 -01
S4E 450-BU03 -02
S4E 450-AU03 -01
S4E 450-AU03 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000 5000 6000
0 1000 2000 [CFM] 3000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
E
1
2
E
E
1350
1300
310
350
1.35
1.55
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 66 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
68
65
Lp
A
[dB(A)]
66
AC axial fans
S series, 450, drawings of directions of air flow "V" and "A"
Without attachments
Type
A4D 450-AU01 -01
A4D 450-AU01 -02
A4E 450-AU03 -01
A4E 450-AU03 -02
"V"
"A"
"V"
"A"
With full round nozzle
Type
W4D450-CU01 -01
W4D450-CU01 -02
W4E 450-CU03 -01
W4E 450-CU03 -02
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
S4D 450-BU01 -01
S4D 450-BU01 -02
S4E 450-BU03 -01
S4E 450-BU03 -02
"V"
"A"
"V"
"A"
Depth of screw
max. 10 mm
Cable gland
"V"
"A" U
"V"
"A" U
"V"
"A" U
b
89
89
99x99
99x99
c
1
6.0
20.0
6.0
20.0
h
33.5
33.5
59.5
59.5
c
2
60.5
74.5
60.5
74.5
67
With guard grille for short nozzle
Type
S4D 450-AU01 -01
S4D 450-AU01 -02
S4E 450-AU03 -01
S4E 450-AU03 -02
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
c
3
19.5
33.5
19.5
33.5
VAC Hz rpm W A F/VDB Pa C kg
3~ 400 50 1330 585 1.10 200 -40 to +70
3~ 400 Y 50 1000 390 0.67 110 -40 to +70
3~ 400 60 1540 660 1.16 110 -40 to +50
3~ 400 Y 60 1060 400 0.70 55 -40 to +50
1~ 230 50 1350 480 2.10 10.0 /400 125 -40 to +65
1~ 230 60 1490 665 2.90 10.0 /400 115 -40 to +50
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
68
AC axial fans
S series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 450 M4D094-HA
*4E 450 M4E 094-HA
subject to alterations
2000 4000 6000
0 1000 2000 3000 4000 [CFM]
[
P
a
]
40
80
120
160
200
0
,
2
0
,
4
0
,
8
[
i
n

H
2 O
]
0
,
6
[m
3
/h]
60 Hz 50 Hz
2
2
1 1
A
B
C
D
Curves
1400
1370
1170
1030
n
[rpm]
P
1
[W]
I
[A]
392
476
303
375
0.89
0.98
0.53
0.63
A
B
A
B
1
2
2
1
p. 416 f.
F1b)/F2b)
A
B
C
D
F1b)/F2b) 7.9
7.9
A2b) 7.9 E
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load
Lp
A
[dB(A)]
72
70
68
66
69
Motor protection: Design with thermal overload protector
Cable exit: Lateral via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A4D 450-BA14 -01
A4D 450-BA14 -02
W4D450-GA14 -01
W4D450-GA14 -02
S4D 450-HA14 -01
S4D 450-HA14 -02
S4D 450-GA14 -01
S4D 450-GA14 -02

"A"
"V" A4E 450-BA09 -01
A4E 450-BA09 -02
W4E 450-GA09 -01
W4E 450-GA09 -02
S4E 450-HA09 -01
S4E 450-HA09 -02
S4E 450-GA09 -01
S4E 450-GA09 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
2000 4000 6000
0 1000 [CFM] 2000 3000 4000
[
P
a
]
40
80
120
160
200
0
,
2
0
,
6
0
,
8
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2
1
E
E
E
1380
1360
413
460
2.01
2.20
1
2
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Streamer
p. 371
Wall ring
p. 372 f.
Guard grille
p. 362 ff.
Drawings
p. 72 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
72
70
Lp
A
[dB(A)]
In-line duct fan

"V"
VAC Hz rpm W A F/VDB Pa C kg
3~ 400 50 1350 490 1.00 115 -40 to +95
3~ 400 Y 50 1075 340 0.58 75 -40 to +95
1~ 230 50 1330 500 2.20 10.0 /400 100 -40 to +80
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
70
AC axial fans
S series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 450 M4E 110-EF
*4D 450 M4D110-EF
subject to alterations
1000 2000 4000 6000 3000 5000 7000
0 [CFM]
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
2000 4000 1000 3000
3
3
2
2
1
1
A
B
0 -5 -10
Curves
1370
1360
1350
1120
1090
1075
n
[rpm]
P
1
[W]
I
[A]
450
470
490
320
330
340
0.97
0.99
1.00
0.56
0.57
0.58
A
A
B
A
B
B
1
2
1
3
3
2
p. 416 f.
F1b)/F2b)
A
B
14.5
A2b) 14.5 C
M
a
s
s

o
f

i
n
-
l
i
n
e

d
u
c
t

f
a
n
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load
Lw
A
[dB(A)]
76
77
79
71
73
75
0
0
B
l
a
d
e

a
n
g
l
e
"V"

"A"
71
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V"

"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 4000 6000 3000 5000 7000
0 [CFM]
[
P
a
]
20
40
60
80
100
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
2000 4000 1000 3000
3
2
1
C
0 -5 -10
C
C
C
1360
1340
1330
460
480
500
2.00
2.10
2.20
1
2
3
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Drawings
p. 73
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
76
77
78
Lw
A
[dB(A)]
In-line duct fan
W4E 450-IG01 -01

W4D450-IG01 -01

"V"
72
AC axial fans
S series, 450, drawings of directions of air flow "V" and "A"
Without attachments
Type
b c h
A4D 450-BA14 -01
A4D 450-BA14 -02
A4E 450-BA09 -01
A4E 450-BA09 -02
89
89
99x99
99x99
35.0
36.7
35.0
36.7
33.5
33.5
59.5
59.5
"V"
"A"
"V"
"A"
With full round nozzle
Type
W4D450-GA14 -01
W4D450-GA14 -02
W4E 450-GA09 -01
W4E 450-GA09 -02
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
S4D 450-HA14 -01
S4D 450-HA14 -02
S4E 450-HA09 -01
S4E 450-HA09 -02
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 12 mm
Cable gland
73
With guard grille for short nozzle
Type
S4D 450-GA14 -01
S4D 450-GA14 -02
S4E 450-GA09 -01
S4E 450-GA09 -02
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
In-line duct fan
Type
W4D450-IG01 -01
W4E 450-IG01 -01
"V"
"V"
"V"
u
64.0
65.7
64.0
65.7
E
F
E
F
E
F
1
2
3
1
2
3
3~ 400 50 1325 0.82 1.59 160 -40 to +80
3~ 400 Y 50 1035 0.55 0.95 100 -40 to +80
3~ 400 50 1360 0.69 1.43 160 -40 to +90
3~ 400 Y 50 1110 0.49 0.86 105 -40 to +90
74
AC axial fans
S series, 500
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 500 M4D110-GF
*4D 500 M4D110-GF
0
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b) -5
C
D
E
F
3~ 400 50 1310 0.58 1.10 155 -40 to +85
3~ 400 Y 50 1010 0.38 0.65 95 -40 to +85
*4D 500 M4D110-EF -10
A
B
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
2000 4000 6000 8000
0 1250 2500
[m
3
/h]
[CFM] 5000 3750
20
40
60
80
120
100
160
140
0
,
2
0
,
4
0
,
6
0 -5 -10
2
2
3
3
3
3
1
1
1
1
C
D
F
A
B
E
2
2
1
1
3
2
2
3
[
P
a
]
[
i
n

H
2 O
]
Curves
1355
1340
1310
1110
1070
1010
1355
1345
1325
1100
1070
1035
1390
1380
1360
1180
1150
1110
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.46
0.50
0.58
0.33
0.34
0.38
0.70
0.75
0.82
0.50
0.52
0.55
0.57
0.62
0.69
0.43
0.46
0.49
76
78
80
72
73
74
77
78
80
73
72
74
76
77
80
73
73
76
0.97
1.01
1.10
0.56
0.60
0.65
1.39
1.44
1.59
0.84
0.87
0.95
1.23
1.29
1.43
0.72
0.77
0.86
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
75
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
"V"
"A"
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
A4D 500-AI01 -01
A4D 500-AI01 -02
W4D500-GI01 -01
W4D500-DI01 -02
S4D 500-CI01 -01

S4D 500-AI01 -01

S4D 500-BI01 -02

S4D 500-AI01 -02

D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 82 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4D 500-AE03 -01
A4D 500-AE03 -02
W4D500-GE03 -01
W4D500-DE03 -02
S4D 500-CE03 -01

S4D 500-AE03 -01

S4D 500-BE03 -02

S4D 500-AE03 -02

"A"
"V" A4D 500-AD03 -01
A4D 500-AD03 -02
W4D500-GD03 -01
W4D500-DD03 -02
S4D 500-CD03 -01

S4D 500-AD03 -01

S4D 500-BD03 -02

S4D 500-AD03 -02


W4D500-ID03 -01
"A"
E
E
E
1
2
3
3~ 400 50 920 0.32 0.75 75 -40 to +75
3~ 400 Y 50 765 0.23 0.40 50 -40 to +75
3~ 400 50 945 0.29 0.74 80 -40 to +80
3~ 400 Y 50 790 0.20 0.36 60 -40 to +80
3~ 400 50 950 0.23 0.69 65 -40 to +80
76
AC axial fans
S series, 500
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6D 500 M6D110-EF
*6D 500 M6D110-EF
*6D 500 M6D110-EF
0
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-5
-10
A
B
C
D
E
3~ 400 50 700 0.21 0.61 45 -40 to +70
3~ 400 Y 50 615 0.12 0.25 34 -40 to +70
*8D 500 M8D110-EF F1b)/F2b) 0
G
H
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
1000 2000 3000 4000 5000 6000
0 1000 2000 3000 [CFM]
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
0 -5 -10
20
40
60
80
0
,
1
0
,
2
0
,
3
3
3
3
3
3
1
1
A
B
D
E
C
2
2
2
1
1
1
2
2
Curves
935
930
920
800
785
765
950
940
945
845
830
790
960
955
950
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.29
0.30
0.32
0.20
0.21
0.23
0.24
0.25
0.29
0.17
0.18
0.20
0.20
0.21
0.23
70
70
71
67
66
67
69
69
72
66
66
68
68
70
71
0.75
0.76
0.75
0.36
0.37
0.40
0.71
0.72
0.74
0.31
0.33
0.36
0.68
0.68
0.69
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
77
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
"V" A8D 500-AG01 -01
A8D 500-AG01 -02
W8D500-GG01 -01
W8D500-DG01 -02
S8D 500-CG01 -01

S8D 500-AG01 -01

S8D 500-BG01 -02

S8D 500-AG01 -02

"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000
0 500 1000 [CFM] 1500 2000 2500
[
P
a
]
10
20
30
40
50 0
,
2
0
[
i
n

H
2 O
]
0
,
1
5
0
,
1
0
0
,
0
5
[m
3
/h]
0 -5 -10
2
2
3
1
1
G
H
3
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 82 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A6D 500-AI03 -01
A6D 500-AI03 -02
W6D500-GI03 -01
W6D500-DI03 -02
S6D 500-CI03 -01

S6D 500-AI03 -01

S6D 500-BI03 -02

S6D 500-AI03 -02

"A"
"V" A6D 500-AH03 -01
A6D 500-AH03 -02
W6D500-GH03 -01
W6D500-DH03 -02
S6D 500-CH03 -01

S6D 500-AH03 -01

S6D 500-BH03 -02

S6D 500-AH03 -02

"A"
"V" A6D 500-AG03 -01
A6D 500-AG03 -02
W6D500-GG03 -01
W6D500-DG03 -02
S6D 500-CG03 -01

S6D 500-AG03 -01

S6D 500-BG03 -02

S6D 500-AG03 -02

"A"
710
710
700
635
630
615
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.19
0.20
0.21
0.11
0.12
0.12
64
62
65
61
60
61
0.64
0.63
0.61
0.23
0.24
0.25
G
G
H
H
H
G
1
2
3
1
2
3
78
AC axial fans
S series, 500
Nominal data
Type Motor VAC Hz rpm kW A F/VDB Pa C
*4E 500 M4E 110-GF
*4E 500 M4E 110-GF
*4E 500 M4E 110-EF
0
p. 416 f.
1~ 230 50 1270 0.76 3.33 14.0 /400 130 -40 to +60
-5
-10
B
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
2000 4000 6000 8000
0 1250 2500
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
[CFM] 5000 3750
20
40
60
80
120
100
160
140
0
,
2
0
,
4
0
,
6
0 -5 -10
2
3
3
1
1
1
B
C
A
2
2
3
Curves
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A2b)
1~ 230 50 1330 0.71 3.10 14.0 /450 160 -40 to +70 C A2b)
1~ 230 50 1300 0.53 2.31 10.0 /450 115 -40 to +75 A A2b)
1345
1320
1300
1305
1285
1270
1375
1355
1330
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.47
0.51
0.53
0.71
0.75
0.76
0.59
0.64
0.71
76
77
78
77
77
78
76
77
80
2.06
2.21
2.31
3.13
3.28
3.33
2.59
2.80
3.10
A
A
B
C
B
B
C
C
A
1
2
3
1
2
3
1
2
3
79
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
A4E 500-AI01 -01
A4E 500-AI01 -02
W4E 500-GI01 -01
W4E 500-DI01 -02
S4E 500-CI01 -01

S4E 500-AI01 -01

S4E 500-BI01 -02

S4E 500-AI01 -02

A4E 500-AE03 -01


A4E 500-AE03 -02
W4E 500-GE03 -01
W4E 500-DE03 -02
S4E 500-CE03 -01

S4E 500-AE03 -01

S4E 500-BE03 -02

S4E 500-AE03 -02

A4E 500-AD03 -01


A4E 500-AD03 -02
W4E 500-GD03 -01
W4E 500-DD03 -02
S4E 500-CD03 -01

S4E 500-AD03 -01

S4E 500-BD03 -02

S4E 500-AD03 -02


W4E 500-ID03 -01

Motor protection: Design with thermal overload protector


Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
"V"
"A"
"V"
"A"
"V"
"A"
Drawings
p. 82 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
80
AC axial fans
S series, 500
Nominal data
Type Motor VAC Hz rpm kW A F/VDB Pa C
*6E 500 M6E 110-EF
*6E 500 M6E 110-EF
*6E 500 M6E 110-EF
0
p. 416 f.
1~ 230 50 890 0.30 1.32 8.0 /400 70 -40 to +80
-5
-10
A
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
1000 2000 3000 4000 5000 6000
0 1000 2000 3000 [CFM]
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
0 -5 -10
20
40
60
80
0
,
1
0
,
2
0
,
3
3
3
3
1
1
1
A
B
C
2
2
2
Curves
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A2b)
1~ 230 50 910 0.27 1.19 8.0 /450 80 -40 to +85 B A2b)
1~ 230 50 930 0.25 1.10 8.0 /450 85 -40 to +85 C A2b)
*8E 500 M8E 110-EF 0 1~ 230 50 690 0.19 1.11 4.0 /450 40 -40 to +80 D A2b)
910
900
890
935
925
910
945
940
930
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.28
0.29
0.30
0.24
0.25
0.27
0.23
0.24
0.25
71
69
70
69
69
72
69
71
74
1.20
1.25
1.32
1.04
1.09
1.19
0.99
1.04
1.10
A
A
B
C
B
B
C
C
A
1
2
3
1
2
3
1
2
3
81
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000
0 500 1000 [CFM] 1500 2000 2500
[
P
a
]
10
20
30
40
50 0
,
2
0
[
i
n

H
2 O
]
0
,
1
5
0
,
1
0
0
,
0
5
[m
3
/h]
0 -5 -10
2
3
1
D
Curves
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
A6E 500-AI03 -01
A6E 500-AI03 -02
W6E 500-GI03 -01
W6E 500-DI03 -02
S6E 500-CI03 -01

S6E 500-AI03 -01

S6E 500-BI03 -02

S6E 500-AI03 -02

A6E 500-AH03 -01


A6E 500-AH03 -02
W6E 500-GH03 -01
W6E 500-DH03 -02
S6E 500-CH03 -01

S6E 500-AH03 -01

S6E 500-BH03 -02

S6E 500-AH03 -02

A6E 500-AG03 -01


A6E 500-AG03 -02
W6E 500-GG03 -01
W6E 500-DG03 -02
S6E 500-CG03 -01

S6E 500-AG03 -01

S6E 500-BG03 -02

S6E 500-AG03 -02


W6E 500-IG03 -01

Motor protection: Design with thermal overload protector


Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
A8E 500-AG01 -01
A8E 500-AG01 -02
W8E 500-GG01 -01
W8E 500-DG01 -02
S8E 500-CG01 -01

S8E 500-AG01 -01

S8E 500-BG01 -02

S8E 500-AG01 -02

"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
695
695
690
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.18
0.19
0.19
64
63
63
1.09
1.10
1.11
D
D
D
1
2
3
Drawings
p. 82 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
82
AC axial fans
S series, 500, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A4D 500-AI01 -01
A4D 500-AD03 -01
A4D 500-AE03 -01
A6D 500-AG03 -01
A6D 500-AH03 -01
A6D 500-AI03 -01
A8D 500-AG01 -01
A4E 500-AI01 -01
A4E 500-AD03 -01
A4E 500-AE03 -01
A6E 500-AG03 -01
A6E 500-AH03 -01
A6E 500-AI03 -01
A8E 500-AG01 -01
92.0
104.0
98.0
104.0
98.0
92.0
104.0
92.0
104.0
98.0
104.0
98.0
92.0
104.0
78.0
101.0
89.0
101.0
89.0
78.0
101.0
78.0
101.0
89.0
101.0
89.0
78.0
101.0
188.5
208.5
208.5
188.5
188.5
188.5
188.5
188.5
208.5
208.5
188.5
188.5
188.5
188.5
8.8
11.0
11.0
8.8
8.8
8.8
8.8
8.8
11.0
11.0
8.8
8.8
8.8
8.8
With full square nozzle
Type Mass
[kg]
W4D500-GI01 -01
W4D500-GD03 -01
W4D500-GE03 -01
W6D500-GG03 -01
W6D500-GH03 -01
W6D500-GI03 -01
W8D500-GG01 -01
W4E 500-GI01 -01
W4E 500-GD03 -01
W4E 500-GE03 -01
W6E 500-GG03 -01
W6E 500-GH03 -01
W6E 500-GI03 -01
W8E 500-GG01 -01
18.6
21.0
21.0
18.6
18.6
18.6
18.6
18.6
21.0
21.0
18.6
18.6
18.6
18.6
With guard grille for full nozzle
Type
r s t
Mass
[kg]
S4D 500-CI01 -01
S4D 500-CD03 -01
S4D 500-CE03 -01
S6D 500-CG03 -01
S6D 500-CH03 -01
S6D 500-CI03 -01
S8D 500-CG01 -01
S4E 500-CI01 -01
S4E 500-CD03 -01
S4E 500-CE03 -01
S6E 500-CG03 -01
S6E 500-CH03 -01
S6E 500-CI03 -01
S8E 500-CG01 -01
63.5
65.5
65.5
65.5
65.5
63.5
63.5
63.5
65.5
65.5
63.5
63.5
63.5
63.5
91.0
103.0
97.0
103.0
97.0
97.0
103.0
91.0
103.0
97.0
103.0
97.0
97.0
103.0
123.0
143.0
143.0
123.0
123.0
123.0
123.0
123.0
143.0
143.0
123.0
123.0
123.0
123.0
12.6
14.8
14.8
12.6
12.6
12.6
12.6
12.6
14.8
14.8
12.6
12.6
12.6
12.6
"V"
"V"
"V"
Depth of screw
max. 12 mm
Cable gland
6,5
View X
83
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 500-AI01 -01
S4D 500-AD03 -01
S4D 500-AE03 -01
S6D 500-AG03 -01
S6D 500-AH03 -01
S6D 500-AI03 -01
S8D 500-AG01 -01
S4E 500-AI01 -01
S4E 500-AD03 -01
S4E 500-AE03 -01
S6E 500-AG03 -01
S6E 500-AH03 -01
S6E 500-AI03 -01
S8E 500-AG01 -01
32.0
44.0
38.0
44.0
38.0
32.0
44.0
32.0
44.0
38.0
44.0
38.0
32.0
44.0
64.0
84.0
84.0
64.0
64.0
64.0
64.0
64.0
84.0
84.0
64.0
64.0
64.0
64.0
13.3
15.5
15.5
13.3
13.3
13.3
13.3
13.3
15.5
15.5
13.3
13.3
13.3
13.3
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W4D500-ID03 -01
W4E 500-ID03 -01
W6E 500-IG03 -01
16.8
16.8
14.8
"V"
"V"
84
AC axial fans
S series, 500, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A4D 500-AI01 -02
A4D 500-AD03 -02
A4D 500-AE03 -02
A6D 500-AG03 -02
A6D 500-AH03 -02
A6D 500-AI03 -02
A8D 500-AG01 -02
A4E 500-AI01 -02
A4E 500-AD03 -02
A4E 500-AE03 -02
A6E 500-AG03 -02
A6E 500-AH03 -02
A6E 500-AI03 -02
A8E 500-AG01 -02
95.0
131.0
126.0
131.0
126.0
120.0
131.0
120.0
131.0
126.0
131.0
126.0
120.0
131.0
78.0
101.0
89.0
101.0
89.0
78.0
101.0
78.0
101.0
89.0
101.0
89.0
78.0
101.0
188.5
208.5
208.5
188.5
188.5
188.5
188.5
188.5
208.5
208.5
188.5
188.5
188.5
188.5
8.8
11.0
11.0
8.8
8.8
8.8
8.8
8.8
11.0
11.0
8.8
8.8
8.8
8.8
With full square nozzle
Type Mass
[kg]
W4D500-DI01 -02
W4D500-DD03 -02
W4D500-DE03 -02
W6D500-DG03 -02
W6D500-DH03 -02
W6D500-DI03 -02
W8D500-DG01 -02
W4E 500-DI01 -02
W4E 500-DD03 -02
W4E 500-DE03 -02
W6E 500-DG03 -02
W6E 500-DH03 -02
W6E 500-DI03 -02
W8E 500-DG01 -02
18.8
21.0
21.0
18.8
18.8
18.8
18.8
18.8
21.0
21.0
18.8
18.8
18.8
18.8
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 500-BI01 -02
S4D 500-BD03 -02
S4D 500-BE03 -02
S6D 500-BG03 -02
S6D 500-BH03 -02
S6D 500-BI03 -02
S8D 500-BG01 -02
S4E 500-BI01 -02
S4E 500-BD03 -02
S4E 500-BE03 -02
S6E 500-BG03 -02
S6E 500-BH03 -02
S6E 500-BI03 -02
S8E 500-BG01 -02
95.0
119.0
119.0
99.0
99.0
95.0
106.0
95.0
119.0
119.0
106.0
101.0
95.0
106.0
99.0
106.0
101.0
106.0
101.0
99.0
99.0
99.0
106.0
101.0
99.0
99.0
99.0
99.0
12.6
14.8
14.8
12.6
12.6
12.6
12.6
12.6
14.8
14.8
12.6
12.6
12.6
12.6
"A" U
Depth of screw
max. 12 mm
Cable gland
"A" U
"A" U
85
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 500-AI01 -02
S4D 500-AD03 -02
S4D 500-AE03 -02
S6D 500-AG03 -02
S6D 500-AH03 -02
S6D 500-AI03 -02
S8D 500-AG01 -02
S4E 500-AI01 -02
S4E 500-AD03 -02
S4E 500-AE03 -02
S6E 500-AG03 -02
S6E 500-AH03 -02
S6E 500-AI03 -02
S8E 500-AG01 -02
45.0
56.0
51.0
56.0
51.0
45.0
56.0
45.0
56.0
51.0
56.0
51.0
45.0
56.0
49.0
69.0
69.0
49.0
49.0
49.0
49.0
49.0
69.0
69.0
49.0
49.0
49.0
49.0
12.3
14.5
14.5
12.3
12.3
12.3
12.3
12.3
14.5
14.5
12.3
12.3
12.3
12.3
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"A" U
3~ 400 50 1305 0.93 1.78 195 -40 to +65
3~ 400 Y 50 995 0.60 1.05 110 -40 to +65
3~ 400 50 1355 1.17 2.53 170 -40 to +60
3~ 400 Y 50 1080 0.80 1.45 113 -40 to +60
3~ 400 50 860 0.50 0.95 80 -40 to +55
3~ 400 Y 50 615 0.30 0.52 40 -40 to +55
86
AC axial fans
S series, 560
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 560 M4D110-GF
*4D 560 M4D110-IA
*6D 560 M6D110-EF
-10
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-5
0
A
B
C
D
E
F
3~ 400 50 890 0.43 0.90 90 -40 to +70
3~ 400 Y 50 660 0.28 0.48 50 -40 to +70
*6D 560 M6D110-EF F1b)/F2b) -5
G
H
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
0
40
80
200
160
120
0
,
2
0
,
4
0
,
6
0
,
8
[m
3
/h]
[CFM]
2000 4000 6000 8000 10000
1500 3000 6000 4500
0 -5 -10
3
3
3
3
1
1
1
A
C
B
D
2
2
2
2
1
[
P
a
]
[
i
n

H
2 O
]
Curves
1350
1330
1305
1085
1040
995
1385
1370
1355
1155
1125
1080
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.76
0.84
0.93
0.53
0.56
0.60
0.99
1.07
1.17
0.72
0.76
0.80
79
79
80
76
75
75
80
80
81
77
76
77
1.50
1.60
1.78
0.89
0.95
1.05
2.33
2.45
2.53
1.28
1.35
1.45
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
87
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
"V" A6D 560-AH03 -01
A6D 560-AH03 -02
W6D560-GH03 -01
W6D560-DH03 -02
S6D 560-CH03 -01

S6D 560-AH03 -01

S6D 560-BH03 -02

S6D 560-AH03 -02

"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
[CFM]
[m
3
/h]
0 -5 -10
40
80
20
60
100
0
,
1
0
,
2
0
,
3
0
,
4
2000 4000 6000 8000
0 1250 2500 5000 3750
3
3
3
3
1
1
1
1
E
G
H
2
2
2
2
F
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 90 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A6D 560-AG03 -01
A6D 560-AG03 -02
W6D560-GG03 -01
W6D560-DG03 -02
S6D 560-CG03 -01

S6D 560-AG03 -01

S6D 560-BG03 -02

S6D 560-AG03 -02


W6D560-IG03 -01
"A"
"V" A4D 560-AB01 -01
A4D 560-AB01 -02
W4D560-GB01 -01
W4D560-DB01 -02
S4D 560-CB01 -01

S4D 560-AB01 -01

S4D 560-BB01 -02

S4D 560-AB01 -02


W4D560-IB01 -01
"A"
"V" A4D 560-AF03 -01
A4D 560-AF03 -02
W4D560-GF03 -01
W4D560-DF03 -02
S4D 560-CF03 -01

S4D 560-AF03 -01

S4D 560-BF03 -02

S4D 560-AF03 -02

"A"
885
875
860
670
645
615
915
900
890
720
695
660
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.43
0.46
0.50
0.28
0.29
0.30
0.36
0.39
0.43
0.25
0.26
0.28
73
73
74
66
66
66
71
71
71
66
65
64
0.87
0.89
0.95
0.49
0.50
0.52
0.78
0.81
0.90
0.40
0.42
0.48
E
E
F
G
F
F
H
G
H
G
H
E
1
2
3
1
2
3
1
2
3
1
2
3
88
AC axial fans
S series, 560
Nominal data
Type Motor VAC Hz rpm kW A F/VDB Pa C
*4E 560 M4E 110-IA
*6E 560 M6E 110-GF
-5
p. 416 f.
1~ 230 50 1300 1.05 4.60 20.0 /400 110 -40 to +60
-5
A
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
0
20
40
100
120
80
60
0
,
1
0
,
2
0
,
3
[m
3
/h]
[CFM]
2000 4000 6000 8000 10000
1500 3000 6000 4500
0 -5 -10
1
A
3
2
0
,
5
0
,
4
[
P
a
]
[
i
n

H
2 O
]
Curves
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A2b)
1~ 230 50 910 0.43 1.95 10.0 /450 90 -40 to +70 B A2b)
1330
1310
1300
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.97
1.01
1.05
79
79
79
4.21
4.39
4.60
A
A
A
1
2
3
89
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
[CFM]
[m
3
/h]
0 -5 -10
40
80
20
60
100
0
,
1
0
,
2
0
,
3
0
,
4
2000 4000 6000 8000
0 1250 2500 5000 3750
3
1
B
2
[
P
a
]
[
i
n

H
2 O
]
Curves
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
A6E 560-AE01 -01
A6E 560-AE01 -02
W6E 560-GE01 -01
W6E 560-DE01 -02
S6E 560-CE01 -01

S6E 560-AE01 -01

S6E 560-BE01 -02

S6E 560-AE01 -02

A4E 560-AB01 -01


A4E 560-AB01 -02
W4E 560-GB01 -01
W4E 560-DB01 -02
S4E 560-CB01 -01

S4E 560-AB01 -01

S4E 560-BB01 -02

S4E 560-AB01 -02


W4E 560-IB01 -01

Motor protection: Design with thermal overload protector


Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
"V"
"A"
"V"
"A"
935
925
910
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.37
0.39
0.43
73
72
72
1.65
1.80
1.95
B
B
B
1
2
3
Drawings
p. 90 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
90
AC axial fans
S series, 560, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A4D 560-AF03 -01
A4D 560-AB01 -01
A6D 560-AG03 -01
A6D 560-AH03 -01
A4E 560-AB01 -01
A6E 560-AE01 -01
95.0
105.0
114.0
105.0
105.0
105.0
96.0
113.0
129.0
113.0
113.0
113.0
208.5
223.5
188.5
188.5
223.5
208.5
11.5
13.5
9.0
9.0
13.5
11.5
With full square nozzle
Type Mass
[kg]
W4D560-GF03 -01
W4D560-GB01 -01
W6D560-GG03 -01
W6D560-GH03 -01
W4E 560-GB01 -01
W6E 560-GE01 -01
20.0
21.5
18.0
18.0
21.5
20.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 560-CF03 -01
S4D 560-CB01 -01
S6D 560-CG03 -01
S6D 560-CH03 -01
S4E 560-CB01 -01
S6E 560-CE01 -01
95.0
105.0
114.0
105.0
105.0
105.0
144.0
159.0
124.0
124.0
159.0
144.0
14.0
15.5
12.0
12.0
15.5
14.0
"V"
"V"
"V"
Depth of screw
max. 12 mm
Cable gland
6,5
View X
91
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 560-AF03 -01
S4D 560-AB01 -01
S6D 560-AG03 -01
S6D 560-AH03 -01
S4E 560-AB01 -01
S6E 560-AE01 -01
35.0
45.0
54.0
45.0
45.0
45.0
84.0
99.0
64.0
64.0
99.0
84.0
15.5
17.0
13.5
13.5
17.0
15.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W4D560-IB01 -01
W6D560-IG03 -01
W4E 560-IB01 -01
20.9
16.4
20.9
"V"
"V"
92
AC axial fans
S series, 560, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A4D 560-AF03 -02
A4D 560-AB01 -02
A6D 560-AG03 -02
A6D 560-AH03 -02
A4E 560-AB01 -02
A6E 560-AE01 -02
134.0
142.0
149.0
142.0
142.0
142.0
96.0
113.0
129.0
113.0
113.0
113.0
208.5
223.5
188.5
188.5
223.5
208.5
11.5
13.5
9.0
9.0
13.5
11.5
With full square nozzle
Type Mass
[kg]
W4D560-DF03 -02
W4D560-DB01 -02
W6D560-DG03 -02
W6D560-DH03 -02
W4E 560-DB01 -02
W6E 560-DE01 -02
20.3
21.8
18.3
18.3
21.8
20.3
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 560-BF03 -02
S4D 560-BB01 -02
S6D 560-BG03 -02
S6D 560-BH03 -02
S4E 560-BB01 -02
S6E 560-BE01 -02
134.0
149.0
114.0
114.0
149.0
134.0
124.0
132.0
139.0
132.0
132.0
132.0
14.0
15.5
12.0
12.0
15.5
14.0
"A" U
Depth of screw
max. 12 mm
Cable gland
"A" U
"A" U
93
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 560-AF03 -02
S4D 560-AB01 -02
S6D 560-AG03 -02
S6D 560-AH03 -02
S4E 560-AB01 -02
S6E 560-AE01 -02
59.0
67.0
74.0
67.0
67.0
67.0
69.0
84.0
49.0
49.0
84.0
69.0
14.5
16.0
12.5
12.5
16.0
14.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"A" U
3~ 400 50 1330 1.94 3.40 200 -40 to +65
3~ 400 Y 50 1040 1.29 2.20 120 -40 to +65
3~ 400 50 1360 1.62 3.02 200 -40 to +65
3~ 400 Y 50 1120 1.12 1.87 130 -40 to +65
3~ 400 50 1340 2.53 4.95 240 -40 to +60
3~ 400 Y 50 1045 1.64 2.88 145 -40 to +60
94
AC axial fans
S series, 630
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 630 M4D138-HF
*4D 630 M4D138-HF
*4D 630 M4D138-LA
-5
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-10
0
A
B
C
D
E
F
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
4000 8000 12000 16000
0 2500 5000
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
160
180
200
220
0
,
2
0
,
4
0
,
8
0
,
6
0 -5 -10
1
1
1
1
C
D
B
A
2
2
2
2
3
3
3
3
[
P
a
]
[
i
n

H
2 O
]
Curves
1350
1335
1330
1095
1065
1040
1390
1380
1360
1190
1160
1120
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
1.66
1.78
1.94
1.16
1.22
1.29
1.29
1.41
1.62
0.98
1.04
1.12
79
79
81
73
73
75
80
80
83
76
75
78
3.03
3.17
3.40
1.95
2.04
2.20
2.58
2.70
3.02
1.65
1.75
1.87
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
95
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
120
160
200
240
0
,
4
0
,
6
0
,
8
1
,
0
0 -5 -10
1
1
F
E
2
2
3
3
0
,
2
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 96 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4D 630-AJ01 -01
A4D 630-AJ01 -02
W4D630-GJ01 -01
W4D630-DJ01 -02
S4D 630-CJ01 -01

S4D 630-AJ01 -01

S4D 630-BJ01 -02

"A"
"V" A4D 630-AO01 -01
A4D 630-AO01 -02
W4D630-GO01 -01
W4D630-DO01 -02
S4D 630-CO01 -01

S4D 630-AO01 -01

S4D 630-BO01 -02

"A"
"V" A4D 630-AN01 -01
A4D 630-AN01 -02
W4D630-GN01 -01
W4D630-DN01 -02
S4D 630-CN01 -01

S4D 630-AN01 -01

S4D 630-BN01 -02

W4D630-IN01 -01
"A"
1355
1345
1340
1085
1065
1045
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
2.28
2.40
2.53
1.56
1.61
1.64
78
79
81
72
73
75
4.43
4.63
4.95
2.73
2.82
2.88
E
E
F
F
F
E
1
2
3
1
2
3
96
AC axial fans
S series, 630, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A4D 630-AN01 -01
A4D 630-AO01 -01
A4D 630-AJ01 -01
147.0
142.0
152.0
133.0
118.0
147.0
251.0
251.0
276.0
20.0
20.0
24.0
With full square nozzle
Type Mass
[kg]
W4D630-GN01 -01
W4D630-GO01 -01
W4D630-GJ01 -01
37.0
37.0
41.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 630-CN01 -01
S4D 630-CO01 -01
S4D 630-CJ01 -01
146.0
141.0
76.0
175.0
175.0
151.0
28.0
28.0
32.0
1
02
6
15,5
92
7
,
5
68
"V"
"V"
"V"
Depth of screw
max. 18 mm
Cable gland
View X
97
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 630-AN01 -01
S4D 630-AO01 -01
S4D 630-AJ01 -01
80.0
75.0
85.0
109.0
109.0
134.0
29.5
29.5
33.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W4D630-IN01 -01 27.9
"V"
"V"
98
AC axial fans
S series, 630, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A4D 630-AN01 -02
A4D 630-AO01 -02
A4D 630-AJ01 -02
175.0
165.0
185.0
133.0
118.0
147.0
251.0
251.0
276.0
20.0
20.0
24.0
With full square nozzle
Type Mass
[kg]
W4D630-DN01 -02
W4D630-DO01 -02
W4D630-DJ01 -02
38.0
38.0
42.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 630-BN01 -02
S4D 630-BO01 -02
S4D 630-BJ01 -02
126.0
116.0
136.0
127.0
127.0
152.0
29.0
29.0
33.0
"A" U
Depth of screw
max. 18 mm
Cable gland
"A" U
"A" U
99
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
E
F
E
F
E
F
1
2
3
1
2
3
3~ 400 50 890 0.61 1.26 105 -40 to +60
3~ 400 Y 50 680 0.40 0.72 60 -40 to +60
3~ 400 50 910 0.53 1.15 110 -40 to +70
3~ 400 Y 50 725 0.38 0.67 70 -40 to +70
3~ 400 50 885 0.83 1.68 120 -40 to +55
3~ 400 Y 50 655 0.53 0.95 68 -40 to +55
100
AC axial fans
S series, 630
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6D 630 M6D110-GF
*6D 630 M6D110-GF
*6D 630 M6D110-IA
-5
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-10
0
A
B
C
D
E
F
3~ 400 50 640 0.38 0.91 62 -40 to +65
3~ 400 Y 50 440 0.21 0.42 30 -40 to +65
*8D 630 M8D110-GF F1b)/F2b) 0
G
H
3~ 400 50 660 0.33 0.85 65 -40 to +75
3~ 400 Y 50 500 0.20 0.40 35 -40 to +75
*8D 630 M8D110-GF F1b)/F2b) -5
I
J
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
0
20
40
100
120
80
60
0
,
1
0
,
2
0
,
3
[m
3
/h]
[CFM]
2000 4000 6000 8000 10000
1500 3000 6000 4500
0 -5 -10
1
1
1
1
1
1
E
A
C D
F
B
3
3
3
3
3
3
2
2
2
2
2
2
0
,
5
0
,
4
[
P
a
]
[
i
n

H
2 O
]
Curves
925
915
890
770
745
680
940
930
910
825
805
725
915
905
885
735
710
655
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.48
0.52
0.61
0.35
0.37
0.40
0.41
0.45
0.53
0.29
0.31
0.38
0.67
0.72
0.83
0.47
0.49
0.53
75
75
76
72
71
71
75
75
78
73
72
74
75
76
76
71
71
70
1.12
1.16
1.26
0.63
0.66
0.72
1.04
1.06
1.15
0.52
0.55
0.67
1.48
1.54
1.68
0.83
0.86
0.95
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
101
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
[CFM]
[m
3
/h]
0 -5 -10
20
40
60
70
10
30
50
0
,
1
0
,
2
2000 4000 6000 8000
0 1250 2500 5000 3750
3
3
3
3
1
1
G
J
2
2
2
2
1
H
I
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 104 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A6D 630-AA01 -01
A6D 630-AA01 -02
W6D630-GA01 -01
W6D630-DA01 -02
S6D 630-CA01 -01

S6D 630-AA01 -01

S6D 630-BA01 -02

S6D 630-AA01 -02


W6D630-IA01 -01
"A"
"V" A6D 630-AF01 -01
A6D 630-AF01 -02
W6D630-GF01 -01
W6D630-DF01 -02
S6D 630-CF01 -01

S6D 630-AF01 -01

S6D 630-BF01 -02

S6D 630-AF01 -02

"A"
"V" A6D 630-AE01 -01
A6D 630-AE01 -02
W6D630-GE01 -01
W6D630-DE01 -02
S6D 630-CE01 -01

S6D 630-AE01 -01

S6D 630-BE01 -02

S6D 630-AE01 -02

"A"
660
655
640
495
475
440
680
675
660
555
535
500
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.33
0.35
0.38
0.19
0.20
0.21
0.28
0.30
0.33
0.17
0.18
0.20
69
69
69
63
62
61
69
70
71
71
71
71
0.84
0.85
0.91
0.40
0.41
0.42
0.81
0.82
0.85
0.36
0.38
0.40
G
G
H
I
H
H
J
I
J
I
J
G
1
2
3
1
2
3
1
2
3
1
2
3
"V" A8D 630-AD01 -01
A8D 630-AD01 -02
W8D630-GD01 -01
W8D630-DD01 -02
S8D 630-CD01 -01

S8D 630-AD01 -01

S8D 630-BD01 -02

S8D 630-AD01 -02

"A"
"V" A8D 630-AE01 -01
A8D 630-AE01 -02
W8D630-GE01 -01
W8D630-DE01 -02
S8D 630-CE01 -01

S8D 630-AE01 -01

S8D 630-BE01 -02

S8D 630-AE01 -02

"A"
102
AC axial fans
S series, 630
Nominal data
Type Motor VAC Hz rpm kW A F/VDB Pa C
*6E 630 M6E 110-GF
*6E 630 M6E 110-GF
*6E 630 M6E 110-IA
-5
p. 416 f.
1~ 230 50 880 0.61 2.65 14.0 /450 100 -40 to +60
-10
0
A
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
0
20
40
100
80
60
0
,
1
0
,
2
0
,
3
0
,
4
[m
3
/h]
[CFM]
2000 4000 6000 8000 10000
1500 3000 6000 4500
0 -5 -10
3
3
1
1
C
A
B
2
3
1
2
2
[
P
a
]
[
i
n

H
2 O
]
Curves
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A2b)
1~ 230 50 905 0.49 2.15 12.0 /450 100 -40 to +70 B A2b)
1~ 230 50 860 0.76 3.35 16.0 /450 100 -40 to +50 C A2b)
*8E 630 M8E 110-GF -5 1~ 230 50 655 0.35 1.79 7.0 /450 60 -40 to +60 D A2b)
905
895
880
925
920
905
890
875
860
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.55
0.58
0.61
0.43
0.45
0.49
0.71
0.73
0.76
75
75
76
75
76
78
76
76
76
2.41
2.51
2.65
1.89
1.99
2.15
3.11
3.23
3.35
A
A
B
C
B
B
C
C
A
1
2
3
1
2
3
1
2
3
A8E 630-AE01 -01
A8E 630-AE01 -02
W8E 630-GE01 -01
W8E 630-DE01 -02
S8E 630-CE01 -01

S8E 630-AE01 -01

S8E 630-BE01 -02

S8E 630-AE01 -02

"V"
"A"
103
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
[CFM]
[m
3
/h]
0 -5 -10
20
40
60
70
10
30
50
0
,
1
0
,
2
2000 4000 6000 8000
0 1250 2500 5000 3750
3
1
D
2
[
P
a
]
[
i
n

H
2 O
]
Curves
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
A6E 630-AA03 -01
A6E 630-AA03 -02
W6E 630-GA03 -01
W6E 630-DA03 -02
S6E 630-CA03 -01

S6E 630-AA03 -01

S6E 630-BA03 -02

S6E 630-AA03 -02


W6E 630-IA03 -01

A6E 630-AF01 -01


A6E 630-AF01 -02
W6E 630-GF01 -01
W6E 630-DF01 -02
S6E 630-CF01 -01

S6E 630-AF01 -01

S6E 630-BF01 -02

S6E 630-AF01 -02

A6E 630-AE01 -01


A6E 630-AE01 -02
W6E 630-GE01 -01
W6E 630-DE01 -02
S6E 630-CE01 -01

S6E 630-AE01 -01

S6E 630-BE01 -02

S6E 630-AE01 -02

Motor protection: Design with thermal overload protector


Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
"V"
"A"
"V"
"A"
"V"
"A"
685
675
655
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.30
0.32
0.35
69
69
69
1.61
1.68
1.79
D
D
D
1
2
3
Drawings
p. 104 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
104
AC axial fans
S series, 630, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A6D 630-AE01 -01
A6D 630-AF01 -01
A6D 630-AA01 -01
A8D 630-AD01 -01
A8D 630-AE01 -01
A6E 630-AE01 -01
A6E 630-AF01 -01
A6E 630-AA03 -01
A8E 630-AE01 -01
108.0
96.0
120.0
120.0
108.0
108.0
96.0
120.0
108.0
116.0
96.0
135.0
135.0
116.0
116.0
96.0
135.0
116.0
208.5
208.5
223.5
208.5
208.5
208.5
208.5
223.5
208.5
12.5
12.5
14.0
12.5
12.5
12.5
12.5
14.0
12.5
With full square nozzle
Type Mass
[kg]
W6D630-GE01 -01
W6D630-GF01 -01
W6D630-GA01 -01
W8D630-GD01 -01
W8D630-GE01 -01
W6E 630-GE01 -01
W6E 630-GF01 -01
W6E 630-GA03 -01
W8E 630-GE01 -01
20.5
20.5
23.0
20.5
20.5
20.5
20.5
23.0
20.5
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 630-CE01 -01
S6D 630-CF01 -01
S6D 630-CA01 -01
S8D 630-CD01 -01
S8D 630-CE01 -01
S6E 630-CE01 -01
S6E 630-CF01 -01
S6E 630-CA03 -01
S8E 630-CE01 -01
97.5
85.5
109.5
109.5
97.5
97.5
85.5
109.5
97.5
111.5
111.5
126.5
133.5
111.5
133.5
111.5
148.5
133.5
14.5
14.5
17.0
14.5
14.5
14.5
14.5
17.0
14.5
"V"
"V"
"V"
Depth of screw
max. 12 mm
Cable gland
6,5
View X
105
With guard grille for short nozzle
Type
u v
Mass
[kg]
S6D 630-AE01 -01
S6D 630-AF01 -01
S6D 630-AA01 -01
S8D 630-AD01 -01
S8D 630-AE01 -01
S6E 630-AE01 -01
S6E 630-AF01 -01
S6E 630-AA03 -01
S8E 630-AE01 -01
23.0
11.0
35.0
35.0
23.0
23.0
11.0
35.0
23.0
59.0
59.0
74.0
59.0
59.0
59.0
59.0
74.0
59.0
16.0
16.0
18.5
16.0
16.0
16.0
16.0
18.5
16.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W6D630-IA01 -01
W6E 630-IA03 -01
21.4
21.4
"V"
"V"
106
AC axial fans
S series, 630, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A6D 630-AE01 -02
A6D 630-AF01 -02
A6D 630-AA01 -02
A8D 630-AD01 -02
A8D 630-AE01 -02
A6E 630-AE01 -02
A6E 630-AF01 -02
A6E 630-AA03 -02
A8E 630-AE01 -02
142.0
134.0
149.0
149.0
142.0
142.0
134.0
149.0
142.0
116.0
96.0
135.0
135.0
116.0
116.0
96.0
135.0
116.0
208.5
208.5
223.5
208.5
208.5
208.5
208.5
223.5
208.5
12.5
12.5
14.0
12.5
12.5
12.5
12.5
14.0
12.5
With full square nozzle
Type Mass
[kg]
W6D630-DE01 -02
W6D630-DF01 -02
W6D630-DA01 -02
W8D630-DD01 -02
W8D630-DE01 -02
W6E 630-DE01 -02
W6E 630-DF01 -02
W6E 630-DA03 -02
W8E 630-DE01 -02
21.0
21.0
23.5
21.0
21.0
21.0
21.0
23.5
21.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 630-BE01 -02
S6D 630-BF01 -02
S6D 630-BA01 -02
S8D 630-BD01 -02
S8D 630-BE01 -02
S6E 630-BE01 -02
S6E 630-BF01 -02
S6E 630-BA03 -02
S8E 630-BE01 -02
164.0
164.0
179.0
164.0
164.0
164.0
164.0
179.0
164.0
162.0
154.0
169.0
169.0
162.0
162.0
154.0
169.0
162.0
14.5
14.5
17.0
14.5
14.5
14.5
14.5
17.0
14.5
"A" U
Depth of screw
max. 12 mm
Cable gland
"A" U
"A" U
107
With guard grille for short nozzle
Type
u v
Mass
[kg]
S6D 630-AE01 -02
S6D 630-AF01 -02
S6D 630-AA01 -02
S8D 630-AD01 -02
S8D 630-AE01 -02
S6E 630-AE01 -02
S6E 630-AF01 -02
S6E 630-AA03 -02
S8E 630-AE01 -02
92.0
84.0
99.0
99.0
92.0
92.0
84.0
99.0
92.0
94.0
94.0
109.0
94.0
94.0
94.0
94.0
109.0
94.0
15.0
15.0
17.5
15.0
15.0
15.0
15.0
17.5
15.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"A" U
3~ 400 50 1350 2.32 4.65 280 -40 to +70
3~ 400 Y 50 1090 1.59 2.78 180 -40 to +70
3~ 400 50 910 1.01 2.40 130 -40 to +80
3~ 400 Y 50 750 0.70 1.33 87 -40 to +80
108
AC axial fans
S series, 710
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 710 M4D138-LA
*6D 710 M6D138-HF
-10
p. 416 f.
F1b)/F2b)
F1b)/F2b) -5
A
B
C
D
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
4000 8000 12000 16000 20000
0 2000 6000 4000 8000
[m
3
/h]
[CFM] 10000 12000
50
0
,
2
100
0
,
4
150
0
,
6
200
0
,
8
250
1
,
0
0 -5 -10
2
3
3
1
1
A
B
2
[
P
a
]
[
i
n

H
2 O
]
Curves
1380
1360
1350
1160
1110
1090
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
1.96
2.21
2.32
1.43
1.55
1.59
82
86
87
78
80
81
4.13
4.49
4.65
2.50
2.70
2.78
A
A
B
B
B
A
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
109
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
4000 8000 12000 16000
0 2500 5000
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
0
,
2
0
,
4
0
,
3
0
,
1
0
,
5
0 -5 -10
2
3
1
1
C
D
2
3
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 110 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A6D 710-AN01 -01
A6D 710-AN01 -02
W6D710-GN01 -01
W6D710-DN01 -02
S6D 710-CN01 -01

S6D 710-AN01 -01

S6D 710-BN01 -02

W6D710-IN01 -01
"A"
"V" A4D 710-AL01 -01
A4D 710-AL01 -02
W4D710-GL01 -01
W4D710-DL01 -02
S4D 710-CL01 -01

S4D 710-AL01 -01

S4D 710-BL01 -02

W4D710-IL01 -01
"A"
925
920
910
780
765
750
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.91
0.97
1.01
0.65
0.68
0.70
72
75
77
69
71
72
2.32
2.38
2.40
1.22
1.27
1.33
C
C
D
D
D
C
1
2
3
1
2
3
110
AC axial fans
S series, 710, drawings for direction of air flow "V"
Without attachments
Type
g
Mass
[kg]
A4D 710-AL01 -01
A6D 710-AN01 -01
276.0
251.0
25.0
21.0
With full square nozzle
Type Mass
[kg]
W4D710-GL01 -01
W6D710-GN01 -01
43.0
39.0
With guard grille for full nozzle
Type
t
Mass
[kg]
S4D 710-CL01 -01
S6D 710-CN01 -01
193.5
168.5
34.0
30.0
1
02
6
15,5
92
7
,
5
68
"V"
"V"
"V"
Depth of screw
max. 18 mm
Cable gland
View X
111
With guard grille for short nozzle
Type
u v
Mass
[kg]
S4D 710-AL01 -01
S6D 710-AN01 -01
31.0
27.0
90.0
65.0
35.5
31.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W4D710-IL01 -01
W6D710-IN01 -01
40.0
36.0
"V"
"V"
112
AC axial fans
S series, 710, drawings for direction of air flow "A"
Without attachments
Type
g
Mass
[kg]
A4D 710-AL01 -02
A6D 710-AN01 -02
276.0
251.0
25.0
21.0
With full square nozzle
Type Mass
[kg]
W4D710-DL01 -02
W6D710-DN01 -02
44.0
40.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S4D 710-BL01 -02
S6D 710-BN01 -02
144.0
154.0
160.0
155.0
35.0
32.0
"A" U
Depth of screw
max. 18 mm
Cable gland
"A" U
"A" U
113
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
E
F
E
F
E
F
1
2
3
1
2
3
3~ 400 50 870 1.45 3.20 150 -40 to +60
3~ 400 Y 50 610 0.81 1.64 75 -40 to +60
3~ 400 50 895 1.14 2.45 160 -40 to +75
3~ 400 Y 50 710 0.75 1.45 98 -40 to +75
3~ 400 50 895 2.00 4.30 180 -40 to +60
3~ 400 Y 50 685 1.27 2.50 100 -40 to +60
114
AC axial fans
S series, 800
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6D 800 M6D138-HF
*6D 800 M6D138-HF
*6D 800 M6D138-LA
-5
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-10
0
A
B
C
D
E
F
3~ 400 50 910 2.18 5.17 120 -40 to +55
3~ 400 Y 50 730 1.47 2.80 75 -40 to +55
*6D 800 M6D138-NA F1b)/F2b) +5
G
H
3~ 400 50 915 2.08 4.62 180 -40 to +60
3~ 400 Y 50 740 1.43 2.66 118 -40 to +60
*6D 800 M6D138-NA F1b)/F2b) 0
I
J
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
160
180
140
0
,
2
0
,
4
0
,
6
0 -5 -10
1
1
1
1
1
1
A
B
D
E
F
C
2
2
2
2
2
2 3
3
3
3
3
3
[
P
a
]
[
i
n

H
2 O
]
Curves
910
890
870
745
690
610
920
910
895
770
735
710
915
900
895
750
705
685
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
1.07
1.23
1.45
0.72
0.79
0.81
0.94
1.04
1.14
0.66
0.71
0.75
1.55
1.75
2.00
1.08
1.16
1.27
72
72
74
68
66
67
74
75
78
70
70
71
71
72
78
68
67
72
2.50
2.69
3.20
1.35
1.49
1.64
2.29
2.40
2.45
1.24
1.34
1.45
3.48
3.72
4.30
2.02
2.17
2.50
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
115
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
160
180
140
0
,
2
0
,
4
0
,
6
0 -5 5 + -10
1
1
1
1
G
H
I
J
2
2
2
2
3
3
3
3
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 118 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A6D 800-AJ01 -01
A6D 800-AJ01 -02
W6D800-GJ01 -01
W6D800-DJ01 -02
S6D 800-CJ01 -01

S6D 800-AJ01 -01

S6D 800-BJ01 -02

W6D800-IJ01 -01
"A"
"V" A6D 800-AO01 -01
A6D 800-AO01 -02
W6D800-GO01 -01
W6D800-DO01 -02
S6D 800-CO01 -01

S6D 800-AO01 -01

S6D 800-BO01 -02

"A"
"V" A6D 800-AN01 -01
A6D 800-AN01 -02
W6D800-GN01 -01
W6D800-DN01 -02
S6D 800-CN01 -01

S6D 800-AN01 -01

S6D 800-BN01 -02

"A"
920
915
910
755
740
730
940
925
915
810
775
740
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
2.01
2.11
2.18
1.40
1.44
1.47
1.63
1.85
2.08
1.22
1.33
1.43
74
74
75
69
69
71
72
73
79
69
70
73
4.99
5.15
5.17
2.68
2.75
2.80
4.26
4.47
4.62
2.25
2.44
2.66
G
G
H
I
H
H
J
I
J
I
J
G
1
2
3
1
2
3
1
2
3
1
2
3
"V" A6D 800-AS01 -01
A6D 800-AS01 -02
W6D800-GS01 -01
W6D800-DS01 -02
S6D 800-CS01 -01

S6D 800-AS01 -01

S6D 800-BS01 -02

"A"
"V" A6D 800-AP01 -01
A6D 800-AP01 -02
W6D800-GP01 -01
W6D800-DP01 -02
S6D 800-CP01 -01

S6D 800-AP01 -01

S6D 800-BP01 -02

"A"
E
F
E
F
E
F
1
2
3
1
2
3
3~ 400 50 680 0.79 2.15 100 -40 to +55
3~ 400 Y 50 540 0.48 1.05 60 -40 to +55
3~ 400 50 665 1.05 2.70 80 -40 to +70
3~ 400 Y 50 500 0.63 1.31 45 -40 to +70
3~ 400 50 660 0.98 2.41 105 -40 to +65
3~ 400 Y 50 515 0.57 1.21 57 -40 to +65
116
AC axial fans
S series, 800
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*8D 800 M8D138-HF
*8D 800 M8D138-LA
*8D 800 M8D138-LA
-5
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
+5
0
A
B
C
D
E
F
3~ 400 50 435 0.37 1.15 44 -40 to +80
3~ 400 Y 50 330 0.20 0.48 25 -40 to +80
*ZD 800 MZD138-HF F1b)/F2b) 0
G
H
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
20
40
60
80
100
0
,
4
0
,
3
0 -5 5 + -10
1
1 1
1
1
1
A
D
B
C
F
E
2
2
2
2
2
2
3
3
3
3
3
3
0
,
1
0
,
2
[
P
a
]
[
i
n

H
2 O
]
Curves
700
690
680
605
575
540
680
670
665
525
510
500
690
680
660
560
530
515
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.60
0.68
0.79
0.40
0.44
0.48
0.96
1.01
1.05
0.60
0.62
0.63
0.76
0.85
0.98
0.50
0.54
0.57
67
67
71
64
63
65
68
69
71
63
63
64
67
67
71
63
62
64
2.08
2.10
2.15
0.87
0.94
1.05
2.57
2.61
2.70
1.26
1.29
1.31
2.21
2.28
2.41
1.06
1.13
1.21
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
Curves
117
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
2000 4000 6000 8000 10000 12000
0 2000 6000 4000
[m
3
/h]
[CFM]
5
10
15
20
30
25
40
45
35
0
,
0
5
0
,
1
0
,
1
5
0 -5 -10
2
3
3
1
1
G
H
2
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 118 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A8D 800-AJ01 -01
A8D 800-AJ01 -02
W8D800-GJ01 -01
W8D800-DJ01 -02
S8D 800-CJ01 -01

S8D 800-AJ01 -01

S8D 800-BJ01 -02

"A"
"V" A8D 800-AT03 -01
A8D 800-AT03 -02
W8D800-GT03 -01
W8D800-DT03 -02
S8D 800-CT03 -01

S8D 800-AT03 -01

S8D 800-BT03 -02

"A"
"V" A8D 800-AN01 -01
A8D 800-AN01 -02
W8D800-GN01 -01
W8D800-DN01 -02
S8D 800-CN01 -01

S8D 800-AN01 -01

S8D 800-BN01 -02

"A"
455
445
435
375
360
330
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.31
0.33
0.37
0.17
0.18
0.20
59
58
61
55
55
55
1.09
1.10
1.15
0.43
0.45
0.48
G
G
H
H
H
G
1
2
3
1
2
3
"V" AZD 800-AM03 -01
AZD 800-AM03 -02
WZD800-GM03 -01
WZD800-DM03 -02
SZD 800-CM03 -01

SZD 800-AM03 -01

SZD 800-BM03 -02

"A"
118
AC axial fans
S series, 800, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A6D 800-AN01 -01
A6D 800-AO01 -01
A6D 800-AJ01 -01
A6D 800-AS01 -01
A6D 800-AP01 -01
A8D 800-AN01 -01
A8D 800-AT03 -01
A8D 800-AJ01 -01
AZD 800-AM03 -01
147.0
142.0
152.0
157.0
152.0
147.0
157.0
152.0
152.0
133.0
118.0
147.0
162.0
147.0
133.0
162.0
147.0
147.0
251.0
251.0
276.0
296.0
296.0
251.0
276.0
276.0
251.0
22.0
22.0
26.0
29.0
29.0
22.0
26.0
26.0
22.0
With full square nozzle
Type Mass
[kg]
W6D800-GN01 -01
W6D800-GO01 -01
W6D800-GJ01 -01
W6D800-GS01 -01
W6D800-GP01 -01
W8D800-GN01 -01
W8D800-GT03 -01
W8D800-GJ01 -01
WZD800-GM03 -01
42.0
42.0
46.0
49.0
49.0
42.0
46.0
46.0
42.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 800-CN01 -01
S6D 800-CO01 -01
S6D 800-CJ01 -01
S6D 800-CS01 -01
S6D 800-CP01 -01
S8D 800-CN01 -01
S8D 800-CT03 -01
S8D 800-CJ01 -01
SZD 800-CM03 -01
136.5
131.5
141.5
146.5
141.5
136.5
146.5
141.5
141.5
165.5
165.5
190.5
210.5
210.5
165.5
190.5
190.5
165.5
32.0
32.0
36.0
39.0
39.0
32.0
36.0
36.0
32.0
1
52
6
15,5
92
7
,
5
68
"V"
"V"
"V"
Depth of screw
max. 18 mm
Cable gland
View X
119
With guard grille for short nozzle
Type
u v
Mass
[kg]
S6D 800-AN01 -01
S6D 800-AO01 -01
S6D 800-AJ01 -01
S6D 800-AS01 -01
S6D 800-AP01 -01
S8D 800-AN01 -01
S8D 800-AT03 -01
S8D 800-AJ01 -01
SZD 800-AM03 -01
17.0
17.0
27.0
32.0
27.0
22.0
32.0
27.0
17.0
51.0
51.0
76.0
96.0
96.0
51.0
76.0
76.0
51.0
34.0
34.0
38.0
41.0
41.0
34.0
38.0
38.0
34.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
In-line duct fan
Type Mass
[kg]
W6D800-IJ01 -01 43.8
"V"
"V"
120
AC axial fans
S series, 800, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A6D 800-AN01 -02
A6D 800-AO01 -02
A6D 800-AJ01 -02
A6D 800-AS01 -02
A6D 800-AP01 -02
A8D 800-AN01 -02
A8D 800-AT03 -02
A8D 800-AJ01 -02
AZD 800-AM03 -02
175.0
165.0
185.0
194.0
185.0
175.0
194.0
185.0
185.0
133.0
188.0
147.0
162.0
147.0
133.0
162.0
147.0
147.0
251.0
251.0
276.0
296.0
296.0
251.0
276.0
276.0
251.0
22.0
22.0
26.0
29.0
29.0
22.0
26.0
26.0
22.0
With full square nozzle
Type Mass
[kg]
W6D800-DN01 -02
W6D800-DO01 -02
W6D800-DJ01 -02
W6D800-DS01 -02
W6D800-DP01 -02
W8D800-DN01 -02
W8D800-DT03 -02
W8D800-DJ01 -02
WZD800-DM03 -02
43.5
43.5
47.5
50.5
50.5
43.5
47.5
47.5
43.5
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 800-BN01 -02
S6D 800-BO01 -02
S6D 800-BJ01 -02
S6D 800-BS01 -02
S6D 800-BP01 -02
S8D 800-BN01 -02
S8D 800-BT03 -02
S8D 800-BJ01 -02
SZD 800-BM03 -02
172.0
162.0
182.0
191.0
182.0
172.0
191.0
182.0
182.0
173.0
173.0
198.0
218.0
218.0
173.0
198.0
198.0
173.0
33.0
33.0
37.0
40.0
40.0
34.0
37.0
37.0
34.0
"A" U
Depth of screw
max. 18 mm
Cable gland
"A" U
"A" U
121
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
E
F
E
F
E
F
1
2
3
1
2
3
3~ 400 50 890 2.45 5.20 160 -40 to +50
3~ 400 Y 50 685 1.56 2.90 95 -40 to +50
3~ 400 50 920 1.96 4.50 170 -40 to +60
3~ 400 Y 50 760 1.37 2.55 115 -40 to +60
3~ 400 50 940 1.53 4.45 170 -40 to +70
3~ 400 Y 50 830 1.14 2.15 130 -40 to +70
122
AC axial fans
S series, 910
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6D 910 M6D138-NA
*6D 910 M6D138-NA
*6D 910 M6D138-NA
0
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-5
-10
G
H
I
J
K
L
3~ 400 50 900 1.84 3.76 150 -40 to +60
3~ 400 Y 50 700 1.20 2.24 88 -40 to +60
*6D 910 M6D138-LA F1b)/F2b) -5
C
D
3~ 400 50 930 1.41 3.20 165 -40 to +75
3~ 400 Y 50 780 1.03 1.90 115 -40 to +75
*6D 910 M6D138-LA F1b)/F2b) -10
E
F
3~ 400 50 880 1.30 2.75 150 -40 to +60
3~ 400 Y 50 670 0.81 1.56 85 -40 to +60
*6D 910 M6D138-HF F1b)/F2b) -10
A
B
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
160
140
0
,
2
0
,
4
0
,
6
0 -5 -10
2
2
3
3
3
3
1
1
1
C
D
F
A
B
E
2
2
2
2
1
1
1
3
3
[
P
a
]
[
i
n

H
2 O
]
Curves
910
890
880
740
700
670
920
910
900
745
720
700
945
935
930
840
805
780
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
1.06
1.21
1.30
0.72
0.78
0.81
1.59
1.72
1.84
1.10
1.15
1.20
1.11
1.27
1.41
0.85
0.96
1.03
77
78
82
72
72
74
76
77
79
71
71
72
78
79
83
75
75
78
2.56
2.72
2.75
1.36
1.47
1.56
3.51
3.67
3.76
2.01
2.11
2.24
2.91
3.08
3.20
1.56
1.74
1.90
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
K
L
K
L
K
L
1
2
3
1
2
3
"V" A6D 910-AR01 -01
A6D 910-AR01 -02
W6D910-GR01 -01
W6D910-DR01 -02
S6D 910-CR01 -01

S6D 910-AR01 -01

S6D 910-BR01 -02

"A"
"V" A6D 910-AK01 -01
A6D 910-AK01 -02
W6D910-GK01 -01
W6D910-DK01 -02
S6D 910-CK01 -01

S6D 910-AK01 -01

S6D 910-BK01 -02

"A"
"V" A6D 910-AL01 -01
A6D 910-AL01 -02
W6D910-GL01 -01
W6D910-DL01 -02
S6D 910-CL01 -01

S6D 910-AL01 -01

S6D 910-BL01 -02

"A"
"V" A6D 910-AO01 -01
A6D 910-AO01 -02
W6D910-GO01 -01
W6D910-DO01 -02
S6D 910-CO01 -01

S6D 910-AO01 -01

S6D 910-BO01 -02

"A"
"V" A6D 910-AQ01 -01
A6D 910-AQ01 -02
W6D910-GQ01 -01
W6D910-DQ01 -02
S6D 910-CQ01 -01

S6D 910-AQ01 -01

S6D 910-BQ01 -02

"A"
"V" A6D 910-AP01 -01
A6D 910-AP01 -02
W6D910-GP01 -01
W6D910-DP01 -02
S6D 910-CP01 -01

S6D 910-AP01 -01

S6D 910-BP01 -02

"A"
Curves
123
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
5000 10000 15000 20000 25000 30000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
160
180
140
0
,
2
0
,
4
0
,
6
0 -5 -10
2
2 3
3
3
3
1
1
1
G
H
J
K
L
I
2
2
2
2
1
1
1
3
3
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 126 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
920
905
890
760
725
685
940
930
920
810
780
760
960
950
940
875
850
830
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
1.99
2.24
2.45
1.39
1.49
1.56
1.64
1.82
1.96
1.20
1.30
1.37
1.24
1.40
1.53
0.94
1.05
1.14
76
76
79
72
70
72
77
78
80
73
73
75
78
80
83
76
77
80
4.65
4.95
5.20
2.57
2.76
2.90
4.33
4.51
4.50
2.23
2.40
2.55
4.27
4.35
4.45
1.79
1.97
2.15
G
G
H
I
H
H
J
I
J
I
J
G
1
2
3
1
2
3
1
2
3
1
2
3
3~ 400 50 665 1.11 2.70 90 -40 to +65
3~ 400 Y 50 495 0.68 1.36 50 -40 to +65
3~ 400 50 645 0.85 2.09 90 -40 to +60
3~ 400 Y 50 450 0.45 1.00 43 -40 to +60
3~ 400 50 425 0.42 1.15 40 -40 to +70
3~ 400 Y 50 315 0.22 0.50 21 -40 to +70
124
AC axial fans
S series, 910
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
Number of blades: 5
Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharge holes: On rotor and stator side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*8D 910 M8D138-LA
*8D 910 M8D138-HF
*ZD 910 MZD138-HF
0
p. 416 f.
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
-5
0
C
D
A
B
E
F
3~ 400 50 430 0.32 0.86 42 -40 to +100
3~ 400 Y 50 320 0.17 0.40 22 -40 to +100
*ZD 910 MZD138-HF F1b)/F2b) -5
G
H
C
u
r
v
e
B
l
a
d
e

a
n
g
l
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
(
1
)
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Nominal data in operating point with maximum load 3 subject to alterations
4000 8000 12000 16000 20000
0 2000 6000 4000 8000
[m
3
/h]
[CFM] 10000 12000
10
20
30
40
60
50
80
90
70
0
,
1
0
,
2
0
,
3
0 -5 -10
2
3 3
3
3
1
1
1
C
D
B
A
2
2
2
1
[
P
a
]
[
i
n

H
2 O
]
Curves
670
655
645
500
460
450
685
675
665
540
515
495
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.73
0.80
0.85
0.43
0.44
0.45
0.94
1.03
1.11
0.62
0.65
0.68
68
68
69
62
60
60
69
69
71
64
63
64
1.94
2.03
2.09
0.95
0.99
1.00
2.49
2.57
2.70
1.23
1.30
1.36
A
A
B
C
B
B
D
C
D
C
D
A
1
2
3
1
2
3
1
2
3
1
2
3
VAC Hz rpm kW A F/VDB Pa C
C
a
p
a
c
i
t
o
r
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
G
G
H
H
H
G
1
2
3
1
2
3
Curves
125
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
In-line duct fan
"V" AZD 910-AN05 -01
AZD 910-AN05 -02
WZD910-GN05 -01
WZD910-DN05 -02
SZD 910-CN05 -01

SZD 910-AN05 -01

SZD 910-BN05 -02

"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
2000 4000 6000 8000 10000 12000 14000
0 2000 6000 4000 8000
[m
3
/h]
[CFM]
5
10
15
20
30
25
40
45
35
0
,
0
5
0
,
1
0
,
1
5
0 -5 -10
2
3
3
3
3
1
1
1
E
F
H
G
2
2
2
1
[
P
a
]
[
i
n

H
2 O
]
"V"/ "A" U "V"/ "A" U "V" "V" "A" U "A" U "V"
Drawings
p. 126 ff.
Motor protection
p. 386 ff.
Speed setting
p. 384 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" AZD 910-AM03 -01
AZD 910-AM03 -02
WZD910-GM03 -01
WZD910-DM03 -02
SZD 910-CM03 -01

SZD 910-AM03 -01

SZD 910-BM03 -02

"A"
"V" A8D 910-AN07 -01
A8D 910-AN07 -02
W8D910-GN07 -01
W8D910-DN07 -02
S8D 910-CN07 -01

S8D 910-AN07 -01

S8D 910-BN07 -02

"A"
"V" A8D 910-AJ03 -01
A8D 910-AJ03 -02
W8D910-GJ03 -01
W8D910-DJ03 -02
S8D 910-CJ03 -01

S8D 910-AJ03 -01

S8D 910-BJ03 -02

"A"
445
435
425
345
330
315
450
440
430
360
340
320
n
[rpm]
P
1
[kW]
I
[A]
Lw
A
[dB(A)]
0.36
0.39
0.42
0.20
0.21
0.22
0.27
0.29
0.32
0.16
0.17
0.17
61
59
61
54
53
53
60
59
61
54
53
53
1.11
1.13
1.15
0.46
0.48
0.50
0.81
0.84
0.86
0.36
0.38
0.40
E
E
F
F
F
E
1
2
3
1
2
3
126
AC axial fans
S series, 910, drawings for direction of air flow "V"
Without attachments
Type
c d g
Mass
[kg]
A6D 910-AO01 -01
A6D 910-AK01 -01
A6D 910-AL01 -01
A6D 910-AP01 -01
A6D 910-AQ01 -01
A6D 910-AR01 -01
A8D 910-AN07 -01
A8D 910-AJ03 -01
AZD 910-AM03 -01
AZD 910-AN05 -01
147.0
152.0
147.0
156.0
152.0
147.0
152.0
156.0
157.0
152.0
104.0
115.0
104.0
123.0
115.0
104.0
115.0
123.0
123.0
115.0
251.0
276.0
276.0
296.0
296.0
296.0
251.0
276.0
251.0
251.0
22.0
27.0
27.0
30.0
30.0
30.0
22.0
27.0
22.0
22.0
With full square nozzle
Type Mass
[kg]
W6D910-GO01 -01
W6D910-GK01 -01
W6D910-GL01 -01
W6D910-GP01 -01
W6D910-GQ01 -01
W6D910-GR01 -01
W8D910-GN07 -01
W8D910-GJ03 -01
WZD910-GM03 -01
WZD910-GN05 -01
42.0
47.0
47.0
50.0
50.0
50.0
42.0
47.0
42.0
42.0
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 910-CO01 -01
S6D 910-CK01 -01
S6D 910-CL01 -01
S6D 910-CP01 -01
S6D 910-CQ01 -01
S6D 910-CR01 -01
S8D 910-CN07 -01
S8D 910-CJ03 -01
SZD 910-CM03 -01
SZD 910-CN05 -01
134.0
139.0
134.0
143.0
139.0
134.0
139.0
143.0
143.0
139.0
163.0
188.0
188.0
208.0
208.0
208.0
163.0
188.0
163.0
163.0
33.0
38.0
38.0
41.0
41.0
41.0
33.0
38.0
33.0
33.0
1
52
9
20
116
1
0
76
"V"
"V"
"V"
Depth of screw
max. 18 mm
Cable gland
View X
127
With guard grille for short nozzle
Type
u v
Mass
[kg]
S6D 910-AO01 -01
S6D 910-AK01 -01
S6D 910-AL01 -01
S6D 910-AP01 -01
S6D 910-AQ01 -01
S6D 910-AR01 -01
S8D 910-AN07 -01
S8D 910-AJ03 -01
SZD 910-CM03 -01
SZD 910-CN05 -01
17.0
22.0
17.0
26.0
22.0
17.0
22.0
26.0
26.0
22.0
46.0
71.0
71.0
91.0
91.0
91.0
46.0
71.0
46.0
46.0
35.0
40.0
40.0
43.0
43.0
43.0
35.0
40.0
35.0
35.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
128
AC axial fans
S series, 910, drawings for direction of air flow "A"
Without attachments
Type
c d g
Mass
[kg]
A6D 910-AO01 -02
A6D 910-AK01 -02
A6D 910-AL01 -02
A6D 910-AP01 -02
A6D 910-AQ01 -02
A6D 910-AR01 -02
A8D 910-AN07 -02
A8D 910-AJ03 -02
AZD 910-AM03 -02
AZD 910-AN05 -02
145.0
154.0
145.0
157.0
154.0
145.0
154.0
157.0
157.0
154.0
104.0
115.0
104.0
123.0
115.0
104.0
115.0
123.0
123.0
115.0
251.0
276.0
276.0
296.0
296.0
296.0
251.0
276.0
251.0
251.0
22.0
27.0
27.0
30.0
30.0
30.0
22.0
27.0
22.0
22.0
With full square nozzle
Type Mass
[kg]
W6D910-DO01 -02
W6D910-DK01 -02
W6D910-DL01 -02
W6D910-DP01 -02
W6D910-DQ01 -02
W6D910-DR01 -02
W8D910-DN07 -02
W8D910-DJ03 -02
WZD910-DM03 -02
WZD910-DN05 -02
43.5
48.5
48.5
51.5
51.5
51.5
43.5
48.5
43.5
43.5
With guard grille for full nozzle
Type
s t
Mass
[kg]
S6D 910-BO01 -02
S6D 910-BK01 -02
S6D 910-BL01 -02
S6D 910-BP01 -02
S6D 910-BQ01 -02
S6D 910-BR01 -02
S8D 910-BN07 -02
S8D 910-BJ03 -02
SZD 910-BM03 -02
SZD 910-BN05 -02
159.0
168.0
159.0
171.0
168.0
159.0
168.0
171.0
171.0
168.0
195.0
215.0
215.0
235.0
235.0
235.0
195.0
215.0
195.0
195.0
34.0
39.0
39.0
42.0
42.0
42.0
34.0
39.0
34.0
34.0
"A" U
Depth of screw
max. 18 mm
Cable gland
"A" U
"A" U
129
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
130
131
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
AC axial fans K series
AC axial fans, K series 250 - 450 132
132
AC axial fans
K series, 250 / 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 250 M4E 068-BF
subject to alterations
200 400 600 800
0 100 300 400 [CFM] 200 500
[
P
a
]
20
40
60
80
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1315
1280
n
[rpm]
P
1
[W]
I
[A]
42
44
0.19
0.20
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 800 1350 41 0.18 1.5 /400 47 60 -25 to +60
1~ 230 60 910 1550 50 0.23 1.5 /400 50 60 -25 to +70
A 1.2
*4E 300-*E M4E 068-BF A1)
1~ 230 50 1100 1100 52 0.23 1.5 /400 53 50 -25 to +45
1~ 230 60 1150 1150 60 0.27 1.5 /400 54 50 -25 to +40
B 1.3
*4E 300-*H M4E 068-CF A1)
1~ 230 50 1340 1350 70 0.31 1.5 /400 58 80 -25 to +60
1~ 230 60 1460 1480 90 0.40 1.5 /400 61 65 -25 to +55
C 1.7
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
133
Motor protection: TOP wired internally
Cable exit: Axial, variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
B C A
Without
attachments
With guard grille
for short nozzle
"V" A4E 250-AE32 -05
A4E 250-AE32 -06
S4E 250-AE32 -01
S4E 250-AE32 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 134 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4E 300-AE20 -05
A4E 300-AE20 -06
S4E 300-EE20 -05
S4E 300-EE20 -06 "A"
"V" A4E 300-AH26 -05
A4E 300-AH26 -06
S4E 300-EH26 -05
S4E 300-EH26 -06 "A"
300 600 900 1200
0 200 400 600 [CFM]
[
P
a
]
20
40
60
80
1
,
0
0
,
2
0
,
3
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
1 1
2
B
C
B
C
B
C
1060
985
1325
1310
53
55
71
73
0.24
0.24
0.32
0.33
1
2
2
1
Curves
n
[rpm]
P
1
[W]
I
[A]
Installation arrangement
134
AC axial fans
K series, 250 / 300, drawings of directions of air flow "V" and "A"
450
3 a
c1

2
7
+ 0
2 j 3
3
-
6
85
58
M4
4
x
9
0

2
7
,
5

9
2

b
Without attachments
Type
a
A4E 250-AE32 -05
A4E 250-AE32 -06
A4E 300-AE20 -05
A4E 300-AE20 -06
A4E 300-AH26 -05
A4E 300-AH26 -06
68.0
68.0
75.0
75.0
75.0
75.0
b
250.0
250.0
294.0
294.0
294.0
294.0
c
1
-9.0
-2.0
-9.0
-3.0
-4.0
-4.0
j
63.0
63.0
63.0
63.0
73.0
73.0
"V"
"A"
"V"
"A"
"V"
"A"
Type
without attachments t
A4E 250-AE32 -05
A4E 250-AE32 -06
A4E 300-AE20 -05
A4E 300-AE20 -06
A4E 300-AH26 -05
A4E 300-AH26 -06
Type
without guard grille
S4E 250-AE32 -01
S4E 250-AE32 -02
S4E 300-EE20 -05
S4E 300-EE20 -06
S4E 300-EH26 -05
S4E 300-EH26 -06
32.0
32.0
38.0
38.0
38.0
38.0
x
260.0
260.0
306.0
306.0
306.0
306.0
"V"
"A"
"V"
"A"
"V"
"A"


x
t
t
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
135
c2
5 4,5
s
u
w
v
r f
With guard grille for short nozzle
Type
c
2
S4E 250-AE32 -01
S4E 250-AE32 -02
S4E 300-EE20 -05
S4E 300-EE20 -06
S4E 300-EH26 -05
S4E 300-EH26 -06
25.0
36.0
66.0
72.0
71.0
71.0
f
271.0
271.0

r
300.0
300.0
360.0
360.0
360.0
360.0
s
13.5
13.5
12.5
12.5
12.5
12.5
u
67.5
67.5
30.0
30.0
30.0
30.0
v
4.5
4.5
4.0
4.0
4.0
4.0
w
33.5
33.5
26.0
26.0
26.0
26.0
"V"
"A"
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
136
AC axial fans
K series, 350
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 7
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 350 M4E 068-DC
subject to alterations
600 1200 1800 2400
0 300 900 1200 [CFM] 600 1500
[
P
a
]
20
40
60
80
0
,
1
0
,
2
0
,
3
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
1335
1300
n
[rpm]
P
1
[W]
I
[A]
110
120
0.52
0.56
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 2390 1350 105 0.50 3.0 /400 63 80 -25 to +50
1~ 230 60 2650 1500 135 0.60 3.0 /400 66 60 -25 to +40
A 2.0
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
137
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Without
attachments
With guard grille
for short nozzle
"V" A4E 350-AF20 -05
A4E 350-AF20 -06
S4E 350-AF20 -01
S4E 350-AF20 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 138 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
26
20

3
5
8
20
26
Installation arrangement
138
AC axial fans
K series, 350, drawings of directions of air flow "V" and "A"
3
55
c13
2
3
83
2
7
,
5
-
2

3
5
0

9
2
85
6

2
7
450
58
4
x
9
0

M4
Without attachments
Type
c
1
A4E 350-AF20 -05
A4E 350-AF20 -06
18.0
28.0
"V"
"A"
Type
without attachments
A4E 350-AF20 -05
A4E 350-AF20 -06
Type
without guard grille
S4E 350-AF20 -01
S4E 350-AF20 -02
"V"
"A"
"V"
"A" U
"V"
"A" U
Depth of screw
max. 5 mm
Brass lead tips
139
4,5
c2
5
15,5
6,5
61,3
4
2
2
3
8
0
With guard grille for short nozzle
Type
c
2
S4E 350-AF20 -01
S4E 350-AF20 -02
19.0
29.0
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
140
AC axial fans
K series, 360
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 3
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6E 360 M6E 068-DF
subject to alterations
400 800 1200 1600 2000
0 250 1000 [CFM] 500 750 1250
[
P
a
]
10
20
30
40
0
,
1
5
[
i
n

H
2 O
]
0
,
1
0
0
,
0
5
[m
3
/h]
60 Hz 50 Hz
2
1
A
Curves
850
820
n
[rpm]
P
1
[W]
I
[A]
65
67
0.29
0.30
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 2030 850 65 0.29 2.5 /400 46 40 -25 to +50
1~ 230 60 2290 960 85 0.38 2.5 /400 51 40 -25 to +40
A 2.0
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
141
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Without
attachments
With guard grille
for short nozzle
"V" A6E 360-AE08 -01
A6E 360-AE08 -02
S6E 360-AE08 -01
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 142 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Installation arrangement
142
AC axial fans
K series, 360, drawings of directions of air flow "V" and "A"
58
4
x
9
0

3
6
0

9
2

2
9
3
83
3
125
0,1
450
6
85
2,5

2
2
7
,
5
M4
0 -
c13
+
Without attachments
Type
c
1
A6E 360-AE08 -01
A6E 360-AE08 -02
13.0
-42.0
"V"
"A"
Type
without attachments
A6E 360-AE08 -01
A6E 360-AE08 -02
Type
without guard grille
S6E 360-AE08 -01

"V"
"A"

3
7
0
97
97
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
143
4,5
15,5
c25 6,5
17
4
0
0
21
With guard grille for short nozzle
Type
c
2
S6E 360-AE08 -01 134.0 "V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
144
AC axial fans
K series, 360
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 4
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 360 M4E 068-DF
*6E 360 M6E 068-DF
subject to alterations
400 800 1200 1600 2000
0 250 750 1000 1250 [CFM] 500
[
P
a
]
10
20
30
40
50
60
0
,
2
0
[
i
n

H
2 O
]
0
,
1
5
0
,
1
0
0
,
0
5
[m
3
/h]
60 Hz 50 Hz
2 2
1 1
A B
Curves
1310
1300
840
790
n
[rpm]
P
1
[W]
I
[A]
116
119
66
71
0.55
0.57
0.29
0.31
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 2275 1320 115 0.54 3.0 /400 55 55 -25 to +40
1~ 230 60 2440 1430 145 0.64 3.0 /400 57 40 -25 to +40
1~ 230 50 1850 850 65 0.29 2.5 /400 49 50 -25 to +55
1~ 230 60 2060 960 85 0.38 2.5 /400 52 40 -25 to +45
A
A1) 2.2
2.1
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
145
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Without
attachments
With guard grille
for short nozzle
"V" A4E 360-AC20 -05
A4E 360-AC20 -06
S4E 360-EC20 -05
"A"
"V" A6E 360-AA08 -05
A6E 360-AA08 -06
S6E 360-EA08 -05
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 146 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Installation arrangement
146
AC axial fans
K series, 360, drawings of directions of air flow "V" and "A"
0
c1
-
3

2
9
2,5
450
85
6
+
2
7
,
5

3
6
0

9
2
h3
83
3
4
x
9
0

58
M4
Without attachments
Type
c
1
h
A4E 360-AC20 -05
A4E 360-AC20 -06
A6E 360-AA08 -05
A6E 360-AA08 -06
8.0
-8.0
-11.0
-8.0
84.0
84.0
103.0
103.0
"V"
"A"
"V"
"A"
Type
without attachments l
A4E 360-AC20 -05
A4E 360-AC20 -06
A6E 360-AA08 -05
A6E 360-AA08 -06
Type
without guard grille
S4E 360-EC20 -05

S6E 360-EA08 -05

43.0
43.0
65.0
65.0
"V"
"A"
"V"
"A"

3
7
0
l
l
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
147
24
c2
5
4
5
6,6
16,6
4
0
0
With guard grille for short nozzle
Type
c
2
S4E 360-EC20 -05
S6E 360-EA08 -05
88.0
65.0
"V"
"V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
148
AC axial fans
K series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 3
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6E 450-AF M6E 074-EI
*6E 450-AG M6E 074-GA
subject to alterations
1000 2000 3000 4000
0 1000 2000 [CFM]
[
P
a
]
10
20
30
40
50
0
,
2
0
[
i
n

H
2 O
]
0
,
1
5
0
,
1
0
0
,
0
5
[m
3
/h]
60 Hz 50 Hz
2
1
A
B
Curves
890
870
880
860
n
[rpm]
P
1
[W]
I
[A]
147
155
151
160
0.65
0.68
0.68
0.71
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 4565 890 140 0.62 4.0 /400 57 45 -25 to +45
1~ 230 50 4550 890 142 0.65 4.0 /400 57 45 -25 to +50
1~ 230 60 5050 990 190 0.84 4.0 /400 61 50 -25 to +40
A
A1) 4.2
3.7
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
149
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Options: Terminal box
Without
attachments
With guard grille
for short nozzle
"V" A6E 450-AF08 -01
A6E 450-AF08 -02
S6E 450-AF08 -01
"A"
"V" A6E 450-AG05 -01
A6E 450-AG05 -02
S6E 450-AG05 -01
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 150 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Installation arrangement
150
AC axial fans
K series, 450, drawings of directions of air flow "V" and "A"
3
7
90
6
0
0
8
5
6
144
2

7
5

2
0
c1

1
0
2

4
4
6
1 a 5
2
- 0 +
0,2
4
x
9
0

M6
Without attachments
Type
a c
1
A6E 450-AF08 -01
A6E 450-AF08 -02
A6E 450-AG05 -01
A6E 450-AG05 -02
117.0
117.0
129.0
129.0
4.0
-18.0
4.0
-18.0
"V"
"A"
"V"
"A"
Type
without attachments
A6E 450-AF08 -01
A6E 450-AF08 -02
A6E 450-AG05 -01
A6E 450-AG05 -02
Type
without guard grille
S6E 450-AF08 -01

S6E 450-AG05 -01

"V"
"A"
"V"
"A"
110
110
10-40
10-40

4
6
0
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 10 mm
151
c25
30
80
5
5
2
2
4
7
6
9
With guard grille for short nozzle
Type
c
2
S6E 450-AF08 -01
S6E 450-AG05 -01
98.0
98.0
"V"
"V"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
152
AC axial fans
K series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Blades: PA plastic, black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*6E 450 M6E 074-EI
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM] 1500 2000 2500
[
P
a
]
10
20
30
40
50 0
,
2
0
[
i
n

H
2 O
]
0
,
1
5
0
,
1
0
0
,
0
5
[m
3
/h]
2
1
A
Curves
880
850
n
[rpm]
P
1
[W]
I
[A]
151
160
0.66
0.70
A
A
1
2
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
A1)
1~ 230 50 4415 900 145 0.64 4.0 /400 61 45 -25 to +55
A 3.7
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
153
Motor protection: TOP wired internally
Cable exit: Lateral
Protection class: I
Product conforming to standards: EN 60335-1, CE
Options: Terminal box
Without
attachments
With guard grille
for short nozzle
"V" A6E 450-AN08 -01
A6E 450-AN08 -02
S6E 450-BN08 -01
S6E 450-BN08 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Guard grille
p. 366
Drawings
p. 154 f.
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Installation arrangement
154
AC axial fans
K series, 450, drawings of directions of air flow "V" and "A"
2
1
1 122 5
6
6
0
0

7
5
8
5
92
0 -
c1
+

1
0
2

4
4
6

2
M6
90
0,2
4
x
9
0

Without attachments
Type
c
1
A6E 450-AN08 -01
A6E 450-AN08 -02
8.0
25.0
"V"
"A"
Type
without attachments
A6E 450-AN08 -01
A6E 450-AN08 -02
Type
without guard grille
S6E 450-BN08 -01
S6E 450-BN08 -02
"V"
"A"
100
100
20

4
5
2
20
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 10 mm
155
c2 5
30
5
9
19
5
2
2
4
7
6
With guard grille for short nozzle
Type
c
2
S6E 450-BN08 -01
S6E 450-BN08 -02
100.0
117.0
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
156
157
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
AC axial fans A series
AC axial fans, A series 200 - 350 158
158
AC axial fans
A series, 200
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 200
(1)
M2D068-CF
*2E 200 M2E 068-CA
*4D 200
(1)
M4D068-CF
subject to alterations
200 400 600
0 100 200 400 [CFM] 300
[
P
a
]
40
80
120
160
200
240
0
,
2
0
,
4
0
,
8
[
i
n

H
2 O
]
0
,
6
[m
3
/h]
60 Hz 50 Hz
2
1 1
2
A
B
Curves
2785
2770
2670
2670
n
[rpm]
P
1
[W]
I
[A]
53
55
51
50
0.15
0.15
0.24
0.24
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 830 2800 53 0.26/0.15 67 140 -25 to +75
3~ 230/400 60 940 3150 70 0.24/0.14 70 140 -25 to +75
1~ 230 50 740 2740 50 0.24 1.5 /400 65 200 -25 to +75
1~ 230 60 830 3120 61 0.28 1.5 /400 69 200 -25 to +75
A
A1) 1.4
1.7
B
3~ 230/400 50 390 1450 22 0.16/0.09 51 70 -25 to +60
3~ 230/400 60 460 1730 21 0.12/0.07 55 100 -25 to +80
C1)/C2) 1.5 C
*4S 200 M4S 068-BF
1~ 230 50 375 1380 40 0.30 52 60 -25 to +50
1~ 230 60 445 1630 34 0.24 53 80 -25 to +65
B) 1.2 D
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
159
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC B
D B
B D C A
D B C A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
"V" A2D 200-AA02 -01
A2D 200-AA02 -02
W2D200-CA02 -01
W2D200-CA02 -02
S2D 200-BA02 -01
S2D 200-BA02 -02 "A"
"V" A2E 200-AF02 -01
A2E 200-AF02 -02
W2E 200-CF02 -01
W2E 200-CF02 -02
S2E 200-BF02 -01
S2E 200-BF02 -02 "A"
"V" A4D 200-AA04 -01
A4D 200-AA04 -02
W4D200-CA04 -01
W4D200-CA04 -02
S4D 200-BA04 -01
S4D 200-BA04 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
100 200 300 400
0 50 100 200 [CFM] 150 250
[
P
a
]
20
40
60
80
100
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
60 Hz 50 Hz
2 2
1
C
D
C
D
C
D
1460
1460
1375
1380
24
24
40
39
0.09
0.09
0.30
0.29
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 365
Drawings
p. 160
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4S 200-AA02 -01
A4S 200-AA02 -02
W4S 200-CA02 -01
W4S 200-CA02 -02
S4S 200-BA02 -01
S4S 200-BA02 -02 "A"
160
AC axial fans
A series, 200, drawings of directions of air flow "V" and "A"
4
5
0

2
0
c3 333

2
7

0
,
1

1
9
5
-
2

9
2
2 733
M
4
58
Without attachments
Type
c
A2D 200-AA02 -01
A2D 200-AA02 -02
A2E 200-AF02 -01
A2E 200-AF02 -02
A4D 200-AA04 -01
A4D 200-AA04 -02
A4S 200-AA02 -01
A4S 200-AA02 -02
21.0
21.0
21.0
21.0
20.0
20.0
20.0
20.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
6
x
6
0

4
5

1
5

2
8
0

2
0
0
7
2
5
0
6
9 80
1
,
2
5
With full round nozzle
Type
W2D200-CA02 -01
W2D200-CA02 -02
W2E 200-CF02 -01
W2E 200-CF02 -02
W4D200-CA04 -01
W4D200-CA04 -02
W4S 200-CA02 -01
W4S 200-CA02 -02
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
245
4 733
4,5
12,5
With guard grille for full nozzle
Type
S2D 200-BA02 -01
S2D 200-BA02 -02
S2E 200-BF02 -01
S2E 200-BF02 -02
S4D 200-BA04 -01
S4D 200-BA04 -02
S4S 200-BA02 -01
S4S 200-BA02 -02
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
161
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
162
AC axial fans
A series, 250
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 250
(1)
M2D068-DF
*2E 250 M2E 068-DF
*4D 250
(1)
M4D068-CF
subject to alterations
400 800 1200 1600
0 250 500 1000 [CFM] 750
[
P
a
]
100
200
300
0
,
5
1
,
0
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
2
1 1
A
B
Curves
2645
2615
2520
2480
n
[rpm]
P
1
[W]
I
[A]
123
131
122
126
0.23
0.24
0.54
0.55
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 1685 2650 110 0.38/0.22 72 300 -25 to +70
3~ 230/400 60 1845 2950 160 0.45/0.26 75 300 -25 to +40
1~ 230 50 1610 2550 115 0.51 4.0 /400 72 150 -25 to +55
1~ 230 60 1740 2750 165 0.74 4.0 /400 73 130 -25 to +50
A
A1) 2.2
2.2
B
3~ 230/400 50 890 1420 30 0.16/0.09 58 90 -25 to +75
3~ 230/400 60 1035 1650 35 0.14/0.08 62 100 -25 to +75
C1)/C2) 1.6 C
*4S 250 M4S 068-CF
1~ 230 50 870 1400 72 0.53 58 80 -25 to +40
1~ 230 60 1000 1620 67 0.46 62 100 -25 to +50
B) 1.7 D
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
163
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC B A
D B
B D C A
D B C A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
"V" A2D 250-AA02 -01
A2D 250-AA02 -02
W2D250-CA02 -01
W2D250-CA02 -02
S2D 250-BA02 -01
S2D 250-BA02 -02 "A"
"V" A2E 250-AE65 -01
A2E 250-AE65 -02
W2E 250-CE65 -01
W2E 250-CE65 -02
S2E 250-BE65 -01
S2E 250-BE65 -02 "A"
"V" A4D 250-AA04 -01
A4D 250-AA04 -02
W4D250-CA04 -01
W4D250-CA04 -02
S4D 250-BA04 -01
S4D 250-BA04 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
200 400 600 800 1000
0 200 400 600 [CFM]
[
P
a
]
20
40
60
80
100
0
,
1
0
,
2
0
,
4
[
i
n

H
2 O
]
0
,
3
[m
3
/h]
60 Hz 50 Hz
2
1
C
D
C
D
C
D
1420
1410
1400
1395
32
33
70
71
0.09
0.09
0.52
0.52
1
2
2
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 365
Drawings
p. 164
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4S 250-AA02 -01
A4S 250-AA02 -02
W4S 250-CA02 -01
W4S 250-CA02 -02
S4S 250-BA02 -01
S4S 250-BA02 -02 "A"
164
AC axial fans
A series, 250, drawings of directions of air flow "V" and "A"
4
5
0

2
0
c3 393

2
7

0
,
1

2
5
0
-
2

9
2
2 a 3
M
4
58
Without attachments
Type
a c
A2D 250-AA02 -01
A2D 250-AA02 -02
A2E 250-AE65 -01
A2E 250-AE65 -02
A4D 250-AA04 -01
A4D 250-AA04 -02
A4S 250-AA02 -01
A4S 250-AA02 -02
83.0
83.0
83.0
83.0
73.0
73.0
73.0
73.0
27.0
27.0
27.0
27.0
19.0
19.0
19.0
19.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
6
x
6
0

4
5

1
5

3
2
0

2
5
4
7
2
9
5
6
9 85
1
,
2
5
With full round nozzle
Type
W2D250-CA02 -01
W2D250-CA02 -02
W2E 250-CE65 -01
W2E 250-CE65 -02
W4D250-CA04 -01
W4D250-CA04 -02
W4S 250-CA02 -01
W4S 250-CA02 -02
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
290
4 a 3
4,5
12,5
With guard grille for full nozzle
Type
a
S2D 250-BA02 -01
S2D 250-BA02 -02
S2E 250-BE65 -01
S2E 250-BE65 -02
S4D 250-BA04 -01
S4D 250-BA04 -02
S4S 250-BA02 -01
S4S 250-BA02 -02
83.0
83.0
83.0
83.0
73.0
73.0
73.0
73.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
165
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
166
AC axial fans
A series, 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2D 300
(1)
M2D068-EC
*2E 300 M2E 068-EC
*4D 300
(1)
M4D068-DF
subject to alterations
600 1200 1800 2400
0 400 800 1200 [CFM]
[
P
a
]
40
80
160
120
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
2
1 1
A
B
Curves
2610
2535
2600
2530
n
[rpm]
P
1
[W]
I
[A]
190
220
149
162
0.32
0.35
0.66
0.71
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 2760 2650 180 0.54/0.31 76 150 -25 to +60
3~ 230/400 60 2940 2800 270 0.71/0.41 77 100 -25 to +40
1~ 230 50 2440 2650 140 0.62 5.0 /400 75 150 -25 to +55
1~ 230 60 2700 2900 190 0.83 5.0 /400 78 150 -25 to +50
A
A1) 2.5
2.7
B
3~ 230/400 50 1740 1370 85 0.36/0.21 66 100 -25 to +55
3~ 230/400 60 1910 1520 110 0.38/0.22 69 110 -25 to +40
C1)/C2) 2.3 C
*4E 300 M4E 068-DF
1~ 230 50 1690 1350 95 0.44 3.0 /400 65 120 -25 to +45
1~ 230 60 1830 1450 105 0.47 2.0 /400 66 100 -25 to +40
A1) 2.3 D
*4S 300 M4S 068-DF
1~ 230 50 1440 1380 94 0.67 62 75 -25 to +30
1~ 230 60 1600 1550 94 0.67 64 60 -25 to +40
B) 2.1 E
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
167
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral, variable
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC, GOST B C A
E D B
D B E C A
E D B C A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
"V" A2D 300-AD02 -01
A2D 300-AD02 -02
W2D300-CD02 -01
W2D300-CD02 -02
S2D 300-BD02 -01
S2D 300-BD02 -02 "A"
"V" A2E 300-AC47 -01
A2E 300-AC47 -02
W2E 300-CC47 -01
W2E 300-CC47 -02
S2E 300-BC47 -01
S2E 300-BC47 -02 "A"
"V" A4D 300-AA02 -01
A4D 300-AA02 -02
W4D300-CA02 -01
W4D300-CA02 -02
S4D 300-BA02 -01
S4D 300-BA02 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
400 800 1200 1600
0 250 500 750 [CFM] 1000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
2
0
,
4
[
i
n

H
2 O
]
0
,
3
[m
3
/h]
60 Hz 50 Hz
2
1
2 2
1 1
C
D
E
C
D
E
C
D
E
1360
1345
1345
1315
1375
1360
86
94
96
101
92
94
0.21
0.22
0.43
0.45
0.67
0.67
1
2
2
2
1
1
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 365
Drawings
p. 168
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
n
[rpm]
P
1
[W]
I
[A]
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V" A4E 300-AA01 -01
A4E 300-AA01 -02
W4E 300-CA01 -01
W4E 300-CA01 -02
S4E 300-BA01 -01
S4E 300-BA01 -02 "A"
"V" A4S 300-AA02 -01
A4S 300-AA02 -02
W4S 300-CA02 -01
W4S 300-CA02 -02
S4S 300-BA02 -01
S4S 300-BA02 -02 "A"
168
AC axial fans
A series, 300, drawings of directions of air flow "V" and "A"
c3 b3
2 a3
M
4

2
7

0
,
1

3
0
0
-
2

9
2
4
5
0

2
0
58
Without attachments
Type
a b c
A2D 300-AD02 -01
A2D 300-AD02 -02
A2E 300-AC47 -01
A2E 300-AC47 -02
A4D 300-AA02 -01
A4D 300-AA02 -02
A4E 300-AA01 -01
A4E 300-AA01 -02
A4S 300-AA02 -01
A4S 300-AA02 -02
101.0
101.0
98.0
98.0
83.0
83.0
83.0
83.0
83.0
83.0
30.0
30.0
20.0
20.0
56.0
56.0
56.0
56.0
30.0
30.0
32.0
32.0
30.0
30.0
20.0
20.0
20.0
20.0
20.0
20.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
4
5

1
5

6
x
6
0

9
3
8
0

3
9
7

3
2
6
11
80 10
With full round nozzle
Type
W2D300-CD02 -01
W2D300-CD02 -02
W2E 300-CC47 -01
W2E 300-CC47 -02
W4D300-CA02 -01
W4D300-CA02 -02
W4E 300-CA01 -01
W4E 300-CA01 -02
W4S 300-CA02 -01
W4S 300-CA02 -02
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
4,5
360 h
4,5
8
With guard grille for full nozzle
Type
h
S2D 300-BD02 -01
S2D 300-BD02 -02
S2E 300-BC47 -01
S2E 300-BC47 -02
S4D 300-BA02 -01
S4D 300-BA02 -02
S4E 300-BA01 -01
S4E 300-BA01 -02
S4S 300-BA02 -01
S4S 300-BA02 -02
64.0
64.0
50.0
37.0
73.0
73.0
73.0
73.0
52.0
52.0
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
169
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
170
AC axial fans
A series, 315
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 315
(1)
M4D068-EC
*4E 315 M4E 068-EC
subject to alterations
400 800 1200 1600 2000
0 250 500 1000 [CFM] 750 1250
[
P
a
]
40
80
120
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
60 Hz 50 Hz
2
1
B
A
Curves
1390
1370
1395
1360
n
[rpm]
P
1
[W]
I
[A]
82
95
123
136
0.19
0.20
0.55
0.60
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 1990 1400 78 0.33/0.19 65 150 -25 to +80
3~ 230/400 60 2260 1590 115 0.36/0.21 68 150 -25 to +60
1~ 230 50 1950 1400 120 0.53 5.0 /400 67 180 -25 to +50
1~ 230 60 2230 1610 135 0.60 4.0 /400 70 120 -25 to +45
A
A1) 2.8
2.8
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
171
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral
Protection class: I
Product conforming to standards: EN 60335-1, also CE
Approvals: CCC
B
B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
"V" A4D 315-AC20 -01
A4D 315-AC20 -02
W4D315-CC20 -01
W4D315-CC20 -02
S4D 315-BC20 -01
S4D 315-BC20 -02 "A"
"V" A4E 315-AA05 -01
A4E 315-AA05 -02
W4E 315-CA05 -01
W4E 315-CA05 -02
S4E 315-BA05 -01
S4E 315-BA05 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 365
Drawings
p. 172
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
172
AC axial fans
A series, 315, drawings of directions of air flow "V" and "A"
223 653
2 a3
M
4

2
7

0
,
1

3
1
2
-
2

9
2
4
5
0

2
0
58
Without attachments
Type
a
A4D 315-AC20 -01
A4D 315-AC20 -02
A4E 315-AA05 -01
A4E 315-AA05 -02
101.0
101.0
92.0
92.0
"V"
"A"
"V"
"A"
4
5

1
5

6
x
6
0

9
3
8
0

3
9
7

3
4
7
11
74 10
With full round nozzle
Type
W4D315-CC20 -01
W4D315-CC20 -02
W4E 315-CA05 -01
W4E 315-CA05 -02
"V"
"A"
"V"
"A"
6,4
375 84
4,5
8
With guard grille for full nozzle
Type
S4D 315-BC20 -01
S4D 315-BC20 -02
S4E 315-BA05 -01
S4E 315-BA05 -02
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
173
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
174
AC axial fans
A series, 350
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 5
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 350
(1)
M4D068-EC
*4E 350 M4E 068-EC
subject to alterations
1000 2000 3000
0 500 1000 [CFM] 1500 2000
[
P
a
]
40
80
120
160
0
,
2
0
,
6
[
i
n

H
2 O
]
0
,
4
[m
3
/h]
60 Hz 50 Hz
2 2
1 1
A
B
Curves
1405
1390
1375
1345
n
[rpm]
P
1
[W]
I
[A]
154
169
147
161
0.39
0.40
0.65
0.71
A
B
A
B
1
2
2
1
VAC Hz m
3
/h rpm W A F/VDB dB(A) Pa C kg p. 416 f.
C1)/C2)
3~ 230/400 50 2900 1420 145 0.68/0.39 69 150 -25 to +45
3~ 230/400 60 3300 1620 190 0.62/0.36 72 150 -25 to +40
1~ 230 50 2850 1390 140 0.62 5.0 /400 68 120 -25 to +60
1~ 230 60 3190 1550 195 0.86 5.0 /400 70 90 -25 to +40
A
A1) 3.1
3.1
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
C
a
p
a
c
i
t
o
r
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) 230 VAC / 400 VAC Y
175
Motor protection: Without TOP, TOP wired internally
Cable exit: Lateral
Protection class: I
Product conforming to standards: EN 60335-1, also CE B
B A
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
"V" A4D 350-AA06 -01
A4D 350-AA06 -02
W4D350-CA06 -01
W4D350-CA06 -02
S4D 350-BA06 -01
S4D 350-BA06 -02 "A"
"V" A4E 350-AA06 -01
A4E 350-AA06 -02
W4E 350-CA06 -01
W4E 350-CA06 -02
S4E 350-BA06 -01
S4E 350-BA06 -02 "A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V"/ "A" U
Terminal box
p. 381
Wall ring
p. 372 f.
Guard grille
p. 365
Drawings
p. 176
Capacitor
p. 382 f.
Electr. connections
p. 416 f.
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
176
AC axial fans
A series, 350, drawings of directions of air flow "V" and "A"
213 703
2 1023
M
4

2
7

0
,
1

3
5
3
-
2

9
2
4
5
0

2
0
58
Without attachments
Type
A4D 350-AA06 -01
A4D 350-AA06 -02
A4E 350-AA06 -01
A4E 350-AA06 -02
"V"
"A"
"V"
"A"
4
5

1
5

6
x
6
0

9
4
4
2

4
6
0

3
9
0
12
80 11
With full round nozzle
Type
W4D350-CA06 -01
W4D350-CA06 -02
W4E 350-CA06 -01
W4E 350-CA06 -02
"V"
"A"
"V"
"A"
6,4
422 85
4,5
11
With guard grille for full nozzle
Type
S4D 350-BA06 -01
S4D 350-BA06 -02
S4E 350-BA06 -01
S4E 350-BA06 -02
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Brass lead tips
Depth of screw
max. 5 mm
177
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
178
179
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC axial fans, EC diagonal fans
EC axial fans 200 - 250 181
EC diagonal fans 180 - 208 180
180
EC diagonal fans
180
Nominal data
Type Motor VDC VDC m
3
/h rpm W A dB(A) Pa C kg
W1G180-AB31 -01 M1G074-BF 24 16-28 900 4550 93 4.30 68 -25 to +60 1.8
W1G180-AB47 -01 M1G074-BF 48 36-57 925 4600 100 2.30 69 -25 to +60 1.8
A
A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
200 400 600 800 1000
0 200 400 [CFM]
[
P
a
]
100
200
300
400
500
600
700
800
1
,
0
2
,
0
[
i
n

H
2 O
]
3
,
0
[m
3
/h]
600
U
R
U
N
A
1'
2'
6
5 1
2
3
4
3'
4'
7
8
Curves (established at 48 VDC)
Guard grille
p. 366

2
0
0

1
6
9
,
7
0,2
70
2,5
90
4
5

2
2
0
+20
400
6
(





1
4
7
,
1
)

2
0
8
C
C
5180
4970
4760
5010
4600
4500
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
133
141
146
140
100
106
A
A
A
A
A
A
1
2
3
4
1
2
71
70
68
69
69
68

70
67
55

70
4340
4550
3920
3790
3660
3790
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
112
105
60
64
68
63
A
A
A
A
A
A
3
4
5
6
7
8
66
67
66
65
63
63
67
55

70
67
55
Red = +
Blue =
Yellow = PWM/Lin control input
White = Tach output
"V" U

0
,
1
5

4
,
3
0,3 12 0,3 12

0
,
1
5

4
,
3
Section C-C
Material:
Wall ring: Die-cast aluminium
Blades: Plastic PA
Rotor: Galvanized
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Technical features: Control input 0-10 VDC /
PWM, tach output, polarity and locked rotor
protection, soft start
EMC:
Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Cable exit: Lateral
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: UL, CSA;
(48 VDC) with CCC A
181
Nominal data
Type Motor VDC VDC m
3
/h rpm W A dB(A) Pa C kg
W1G200-HH77 -52 M1G074-BF 24 16-28 1090 2950 55 2.60 60 -25 to +60 2.1
W1G200-HH01 -52 M1G074-BF 48 36-57 1005 2750 45 1.10 60 -25 to +60 2.1
B
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
EC axial fans
200
200 400 600 800 1000
0 200 400 600
[
P
a
]
40
80
120
160
200
240
0
,
2
0
,
4
0
,
8
1
,
0
[
i
n

H
2 O
]
0
,
6
[m
3
/h]
[CFM]
UR
UN
8
7
6
5 1
2
3
4
1'
2'
3'
4'
B
Curves (established at 24 VDC)
Guard grille
p. 369
2,6
7
80
0,3
1
2
4

4
,
5
+
0
,
2
240
260
2
2
5
PE + (1)(2)
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
2300
2970
3100
2970
2950
2890
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
73
77
80
80
55
58
B 1
2
3
4
1
2
63
62
63
66
60
60

67
64
54

67
2800
2780
2270
2230
2170
2130
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
61
63
27
28
29
30
B
B B
B B
B B
B B
B B
3
4
5
6
7
8
61
64
55
54
54
57
64
54

67
64
54
"V" U
(1) Control input
(2) Tach output
Material:
Wall ring: Die-cast aluminium
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 9
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 42
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Technical features: Control input 0-10 VDC /
PWM, tach output, polarity and locked rotor
protection
EMC:
Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Connection leads: Terminal strip
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: UL, CSA;
(48 VDC) with CCC B
182
EC diagonal fans
208
Nominal data
Type Motor VDC VDC m
3
/h rpm W A dB(A) Pa C kg
W1G208-BA35 -52 M1G074-BF 24 16-28 1050 3500 96 4.40 74 -25 to +72 2.3
W1G208-BA73 -52 M1G074-BF 48 36-57 1050 3500 96 2.26 74 -25 to +72 2.3
A
A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
200 400 600 800 1000
0 200 400 [CFM]
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
50
100
150
200
250
300
1
,
0
0
0
,
7
5
0
,
5
0
0
,
2
5
600
U
R
U
N
A
1'
2'
6
5 1
2
3
4
3'
4'
7
8
Curves
Guard grille
p. 367
3740
3500
3450
3530
3500
3300
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
116
118
119
118
96
99
A
A
A
A
A
A
1
2
3
4
1
2
75
74
73
75
74
72

52
53
48

52
3250
3330
2960
2830
2780
2840
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
100
99
58
63
64
62
A
A
A
A
A
A
3
4
5
6
7
8
72
73
70
69
68
70
53
48

52
53
48

4
,
5

4
,
5
10
0,3
10
0,3
"V" U
Section C-C
Red = +
Blue =
Yellow = PWM/Lin control input
White = Tach output
Material:
Wall ring: Die-cast aluminium
Blades: Plastic PA
Rotor: Galvanized
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 20
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Technical features: Control input 0-10 VDC /
PWM, tach output, polarity and locked rotor
protection
EMC:
Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Connection leads: Terminal strip
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: VDE, UL, CSA;
(48 VDC) with CCC A
183
Nominal data
Type Motor VDC VDC m
3
/h rpm W A dB(A) Pa C kg
W1G250-HH37 -52 M1G074-BF 24 16-28 1920 2750 105 5.00 70 -25 to +60 2.5
W1G250-HH67 -52 M1G074-BF 48 36-57 1920 2750 105 2.60 70 -25 to +60 2.5
B
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
subject to alterations
EC axial fans
250
400 800 1200 1600
0 400 800
[
P
a
]
40
80
120
160
200
240
0
,
2
0
,
4
0
,
6
0
,
8
[
i
n

H
2 O
]
[m
3
/h]
[CFM]
UR
UN
8
7
6
5 1
2
3
4
4'
3'
2'
1'
B
Curves
Guard grille
p. 369
2,6
7
80
0,3
1
2
4

5
,
4
+
0
,
2
295
320
2
8
0
PE + (1)(2)
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
2920
2800
2680
2600
2750
2630
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
129
132
135
139
105
110
B 1
2
3
4
1
2
71
72
71
72
70
69

63
60
45

63
2520
2440
2610
2320
2230
2170
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
111
114
73
75
78
80
B
B B
B B
B B
B B
B B
3
4
5
6
7
8
69
70
66
67
67
68
60
45

63
60
45
"V" U
(1) Control input
(2) Tach output
Material:
Wall ring: Die-cast aluminium
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 42
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Technical features: Control input 0-10 VDC /
PWM, tach output, polarity and locked rotor
protection
EMC:
Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Connection leads: Terminal strip
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: VDE, UL, CSA;
(48 VDC) with CCC B
184
185
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC axial fans S series
EC axial fans, S series, mains-powered 250 - 990 198
EC axial fans, S series, 24 / 48 VDC 200 - 300 186
186
EC axial fans 24 / 48 VDC
S series, 200
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 9
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 42
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*1G 200 M1G074-BF
*1G 200 M1G074-BF
subject to alterations
200 400 600 800 1000
0 200 400 600
[
P
a
]
40
80
120
160
200
240
0
,
2
0
,
4
0
,
8
1
,
0
[
i
n

H
2 O
]
0
,
6
[m
3
/h]
[CFM]
UR
UN
8
7
6
5 1
2
3
4
1'
2'
3'
4'
A
Curves (established at 24 VDC)
VDC VDC m
3
/h rpm W A dB(A) Pa C kg
24 16-28 1090 2950 55 2.60 60 -25 to +60 1.5 A
48 36-57 1005 2750 45 1.10 60 -25 to +60 1.5 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
2300
2970
3100
2970
2950
2890
2800
2780
2270
2230
2170
2130
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
73
77
80
80
55
58
61
63
27
28
29
30
63
62
63
66
60
60
61
64
55
54
54
57

67
64
54

67
64
54

67
64
54
A
A
1
2
A 3
A 4
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
p. 420
G)
G)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
(1) Increased noise levels in "V" direction of air flow
187
Technical features: Tach output
Control input 0-10 VDC / PWM Polarity and locked rotor protection
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Cable exit: Variable
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: UL, CSA
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
(1)
With guard grille
for short nozzle
"V" A1G 200-AH77 -52
A1G 200-AI77 -52
W1G200-CH77 -52
W1G200-CI77 -52
S1G 200-BH77 -52
S1G 200-BI77 -52
S1G 200-AH77 -52
S1G 200-AI77 -52
A1G 200-AH01 -52
A1G 200-AI01 -52
W1G200-CH01 -52
W1G200-CI01 -52
S1G 200-BH01 -52
S1G 200-BI01 -52
S1G 200-AH01 -52
S1G 200-AI01 -52
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 188 f.
Electr. connection
p. 420
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
188
EC axial fans 24 / 48 VDC
S series, 200, drawings of directions of air flow "V" and "A"

1
9
7
-
2
35
3
5
17

9
2
1
65
+20
450
85
6
5
8

0
,1
5
3
2
,
7
M4
Without attachments
Type
A1G 200-AH77 -52
A1G 200-AI77 -52
A1G 200-AH01 -52
A1G 200-AI01 -52
"V"
"A"
"V"
"A"

2
0
0
1
,
2
5

2
8
0
2
5
0
9
5
80
15
7
6
x
6
0

With full round nozzle


Type
W1G200-CH77 -52
W1G200-CI77 -52
W1G200-CH01 -52
W1G200-CI01 -52
"V"
"A"
"V"
"A"
3,9
2
4
5
4,6
With guard grille for full nozzle
Type
S1G 200-BH77 -52
S1G 200-BI77 -52
S1G 200-BH01 -52
S1G 200-BI01 -52
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 6 mm
Brass lead tips
189
3,9
46
13
23
5
2
6
0
6,5
With guard grille for short nozzle
Type
S1G 200-AH77 -52
S1G 200-AI77 -52
S1G 200-AH01 -52
S1G 200-AI01 -52
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
190
EC axial fans 24 / 48 VDC
S series, 250
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7 for direction of air flow "V", 9 for direction of air flow "A"
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 42
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*1G 250 M1G074-BF
*1G 250 M1G074-BF
subject to alterations
400 800 1200 1600
0 400 800
[
P
a
]
40
80
120
160
200
240
0
,
2
0
,
4
0
,
6
0
,
8
[
i
n

H
2 O
]
[m
3
/h]
[CFM]
UR
UN
8
7
6
5 1
2
3
4
4'
3'
2'
1'
A
Curves
VDC VDC m
3
/h rpm W A dB(A) Pa C kg
24 16-28 1920 2750 105 5.00 70 -25 to +60 1.6 A
48 36-57 1920 2750 105 2.60 70 -25 to +60 1.6 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
2920
2800
2680
2600
2750
2630
2520
2440
2610
2320
2230
2170
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
129
132
135
139
105
110
111
114
73
75
78
80
71
72
71
73
70
69
69
71
66
67
67
68

63
60
45

63
60
45

63
60
45
A
A
1
2
A 3
A 4
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
p. 420
G)
G)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
191
Technical features: Tach output
Control input 0-10 VDC / PWM Polarity and locked rotor protection
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Cable exit: Variable
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: UL, CSA
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
(1)
With guard grille
for short nozzle
"V" A1G 250-AH37 -52
A1G 250-AI37 -52
W1G250-CH37 -52
W1G250-CI37 -52
S1G 250-BH37 -52
S1G 250-BI37 -52
S1G 250-AH37 -52
S1G 250-AI37 -52
A1G 250-AH67 -52
A1G 250-AI67 -52
W1G250-CH67 -52
W1G250-CI67 -52
S1G 250-BH67 -52
S1G 250-BI67 -52
S1G 250-AH67 -52
S1G 250-AI67 -52
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 192 f.
Electr. connection
p. 420
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
(1) Increased noise levels in "V" direction of air flow
192
EC axial fans 24 / 48 VDC
S series, 250, drawings of directions of air flow "V" and "A"

2
5
1
-
2
+
1
35
3
5
21

9
2
1
65
+20
450
85
6
5
8

0
,1
5
3
2
,
7
M4
Without attachments
Type
A1G 250-AH37 -52
A1G 250-AI37 -52
A1G 250-AH67 -52
A1G 250-AI67 -52
"V"
"A"
"V"
"A"

2
5
7
1
,
2
5

3
2
0
2
9
5
9
6
87
15
7
6
x
6
0

With full round nozzle


Type
W1G250-CH37 -52
W1G250-CI37 -52
W1G250-CH67 -52
W1G250-CI67 -52
"V"
"A"
"V"
"A"
3,9
2
9
0
4,6
With guard grille for full nozzle
Type
S1G 250-BH37 -52
S1G 250-BI37 -52
S1G 250-BH67 -52
S1G 250-BI67 -52
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 6 mm
Brass lead tips
193
3,9
45
18
27
5
3
0
0
6,5
With guard grille for short nozzle
Type
S1G 250-AH37 -52
S1G 250-AI37 -52
S1G 250-AH67 -52
S1G 250-AI67 -52
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
194
EC axial fans 24 / 48 VDC
S series, 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
Number of blades: 7
Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
Type of protection: IP 42
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*1G 300 M1G074-CF
*1G 300 M1G074-CF
subject to alterations
1200
600 1200 1800 2400
0 400 800 [CFM]
[
P
a
]
40
80
120
160
0
,
2
0
,
4
0
,
6
[
i
n

H
2 O
]
[m
3
/h]
UR
UN
5
6
7
8
4
3
2
1 1'
2'
3'
4'
A
Curves
VDC VDC m
3
/h rpm W A dB(A) Pa C kg
24 16-28 2450 1800 90 4.00 65 -25 to +60 2.2 A
48 36-57 2450 1800 90 2.00 65 -25 to +60 2.2 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
V
o
l
t
a
g
e

r
a
n
g
e
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
1940
1850
1790
1720
1800
1720
1670
1600
1480
1440
1400
1350
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
108
111
113
116
90
89
91
93
49
52
55
58
67
66
66
66
65
65
65
64
61
62
61
59

71
71
60

71
71
60

71
71
60
A
A
1
2
A 3
A 4
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
p. 420
G)
G)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
195
Technical features: Tach output
Control input 0-10 VDC / PWM Polarity and locked rotor protection
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Cable exit: Variable
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: UL, CSA
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A1G 300-AE19 -54
A1G 300-AE19 -52
W1G300-CE19 -54
W1G300-CE19 -52
S1G 300-BE19 -54
S1G 300-BE19 -52
S1G 300-AE19 -54
S1G 300-AE19 -52
A1G 300-AE33 -54
A1G 300-AE33 -52
W1G300-CE33 -54
W1G300-CE33 -52
S1G 300-BE33 -54
S1G 300-BE33 -52
S1G 300-AE33 -54
S1G 300-AE33 -52
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 196 f.
Electr. connection
p. 420
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
196
EC axial fans 24 / 48 VDC
S series, 300, drawings of directions of air flow "V" and "A"
M4
0,15
4
x
9
0

3
1
58
-
2

3
0
0
60
3
c
5

9
2
6
85
1
75
+20
450
Without attachments
Type
c
A1G 300-AE19 -54
A1G 300-AE19 -52
A1G 300-AE33 -54
A1G 300-AE33 -52
19.7
19.2
19.7
19.2
"V"
"A"
"V"
"A"
3
8
0

3
9
7

3
2
6
11
80
1
5

6
x
6
0

9
With full round nozzle
Type
W1G300-CE19 -54
W1G300-CE19 -52
W1G300-CE33 -54
W1G300-CE33 -52
"V"
"A"
"V"
"A"
4,6
3
6
0
3,9
With guard grille for full nozzle
Type
S1G 300-BE19 -54
S1G 300-BE19 -52
S1G 300-BE33 -54
S1G 300-BE33 -52
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Depth of screw
max. 6 mm
Brass lead tips
197
3
6
0
50
4,5 4,3
With guard grille for short nozzle
Type
S1G 300-AE19 -54
S1G 300-AE19 -52
S1G 300-AE33 -54
S1G 300-AE33 -52
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 3050 175 1.40 210 -25 to +60 2.4 J1)
198
EC axial fans mains-powered
S series, 250
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 7 for direction of air flow "V", 9 for direction of air flow "A"
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 250 M3G074-CF
*3G 250 M3G074-CF
subject to alterations
40
80
120
160
200
0
,
2
0
,
4
0
,
6
400
250
800 1200 1600 2000
500 750 1000 1250 0
A
3
4
2
9
10
11
12
6
5 1
7
8
[CFM]
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 2850 170 2.20 170 -25 to +60 2.4 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 423
J1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
2850
2820
2800
2770
2360
2360
2340
2310
1650
1650
1650
1650
162
158
153
144
85
91
94
95
33
35
36
37
71
71
72
74
66
66
67
68
62
56
58
59

84
84
79

77
77
70

68
70
68
I
[A]
1.80
1.90
2.00
2.00
1.10
1.20
1.20
1.20
0.50
0.50
0.50
0.50
199
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Tach output
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60950-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
Approvals: VDE, UL, CSA, CCC, GOST are applied for
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
(2)
With guard grille
for short nozzle
"V" A3G 250-AC71 -01
A3G 250-AD71 -01
W3G250-CC71 -01
W3G250-CD71 -01
S3G 250-BC71 -01
S3G 250-BD71 -01
S3G 250-AC71 -01
S3G 250-AD71 -01
A3G 250-AC54 -01
A3G 250-AD54 -01
W3G250-CC54 -01
W3G250-CD54 -01
S3G 250-BC54 -01
S3G 250-BD54 -01
S3G 250-AC54 -01
S3G 250-AD54 -01
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
40
80
120
160
200
0
,
2
0
,
4
0
,
6
400
250
800 1200 1600 2000
500 750 1000 1250 0
B
3
4
2
9
10
11
12
6
5 1
7
8
[CFM]
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 200 f.
Electr. connection
p. 423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
3050
2970
2900
2820
2500
2410
2360
2300
1740
1700
1660
1610
170
169
169
168
96
94
94
94
37
37
37
37
72
73
74
75
68
68
69
69
57
56
58
59

89
88
86

86
86
81

75
75
72
I
[A]
1.30
1.30
1.30
1.30
0.70
0.70
0.70
0.70
0.30
0.30
0.30
0.30
(2) Increased noise levels in "V" direction of air flow
200
EC axial fans mains-powered
S series, 250, drawings of directions of air flow "V" and "A"
353
4
5
0
+
2
0
8
5
8
105,21
213
32,50,5
30,2

1
3
3

0
,
3

1
1
5
,
3

2
5
1

9
2
,
1
4
x
9
0

4
5

1
2
5
9
0

5
8
M4
M4
M4
+
1
-
2
Without attachments
Type
A3G 250-AC71 -01
A3G 250-AD71 -01
A3G 250-AC54 -01
A3G 250-AD54 -01
"V"
"A"
"V"
"A"
7
6
x
6
0

1
5

2
9
5

3
2
0

2
5
0

2
5
7

1
94,42
86,52
6
With full round nozzle
Type
W3G250-CC71 -01
W3G250-CD71 -01
W3G250-CC54 -01
W3G250-CD54 -01
"V"
"A"
"V"
"A"
4,2 55,253 33,251

2
9
0

1
,
5

2
5
0

1
5
With guard grille for full nozzle
Type
S3G 250-BC71 -01
S3G 250-BD71 -01
S3G 250-BC54 -01
S3G 250-BD54 -01
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
(1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm
(1)
(2)
(3)
201
17,253
381,5
71,252

3
0
0

1
,
5

2
8
1

1
5
6,2
With guard grille for short nozzle
Type
S3G 250-AC71 -01
S3G 250-AD71 -01
S3G 250-AC54 -01
S3G 250-AD54 -01
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1710 110 0.70 110 -25 to +60 2.7 J1)
202
EC axial fans mains-powered
S series, 300
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 300 M3G074-CF
*3G 300 M3G074-CF
subject to alterations
400
250
800 1200 1600 2000
500 750 1000 1250 0
20
40
60
80
100
0
,
1
0
,
3
0
,
4
0
,
2
A
3
4
2
9
10
11
12
6
5 1
7
8
[CFM]
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1790 125 1.70 110 -25 to +60 2.7 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 423
J1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1790
1770
1750
1720
1460
1430
1420
1400
1030
1030
1020
1010
92
98
101
106
50
53
55
58
21
22
23
24
64
64
63
62
58
58
57
56
48
49
48
46

62
66
67

61
67
65

52
55
59
I
[A]
1.20
1.30
1.30
1.40
0.70
0.70
0.80
0.80
0.30
0.30
0.40
0.40
203
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Tach output
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60950-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
Approvals: VDE, UL, CSA, CCC, GOST are applied for
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 300-AB77 -01
A3G 300-AB77 -02
W3G300-CB77 -01
W3G300-CB77 -02
S3G 300-BB77 -01
S3G 300-BB77 -02
S3G 300-AB77 -01
S3G 300-AB77 -02
A3G 300-AB56 -01
A3G 300-AB56 -02
W3G300-CB56 -01
W3G300-CB56 -02
S3G 300-BB56 -01
S3G 300-BB56 -02
S3G 300-AB56 -01
S3G 300-AB56 -02
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
400
250
800 1200 1600 2000
500 750 1000 1250 0
20
40
60
80
100
0
,
1
0
,
3
0
,
4
0
,
2
B
3
4
2
9
10
11
12
6
5 1
7
8
[CFM]
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 204 f.
Electr. connection
p. 423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1710
1680
1670
1650
1410
1390
1345
1375
1000
990
990
980
76
81
85
89
49
52
54
57
21
22
23
24
62
62
62
60
56
57
56
55
47
48
46
45

64
66
69

57
61
61

54
58
60
I
[A]
0.60
0.60
0.60
0.70
0.40
0.40
0.50
0.50
0.20
0.20
0.20
0.20
204
EC axial fans mains-powered
S series, 300, drawings of directions of air flow "V" and "A"
105,21
c3
32,50,5
30,2

1
3
3

0
,
3

1
1
5
,
3
603
4
5
0
+
2
0
8
5
8

3
0
0
-
2

9
2
,
1
4
x
9
0

4
5

1
2
5
9
0

5
8
M4
M4
M4
Without attachments
Type
c
A3G 300-AB77 -01
A3G 300-AB77 -02
A3G 300-AB56 -01
A3G 300-AB56 -02
16.5
16.0
16.5
16.0
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G300-CB77 -01
W3G300-CB77 -02
W3G300-CB56 -01
W3G300-CB56 -02
"V"
"A"
"V"
"A"
4,2 75,753 33,251
5

3
6
0

1
,
5

3
3
0

1
With guard grille for full nozzle
Type
S3G 300-BB77 -01
S3G 300-BB77 -02
S3G 300-BB56 -01
S3G 300-BB56 -02
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
(1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm
(1)
(2)
(3)
205
With guard grille for short nozzle
Type
S3G 300-AB77 -01
S3G 300-AB77 -02
S3G 300-AB56 -01
S3G 300-AB56 -02
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1660 170 1.30 130 -25 to +60 2.9 J1)
206
EC axial fans mains-powered
S series, 315
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 315 M3G074-CF
*3G 315 M3G074-CF
subject to alterations
[m
3
/h]
[CFM] 0
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
600 1200 1800 2400
400 800 1200
A
3
4
2
9
10
11
12
6
5 1
7
8
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1670 160 2.10 110 -25 to +60 2.9 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 423
J1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1670
1660
1630
1610
1130
1120
1120
1110
560
560
560
560
109
118
126
138
38
42
45
49
8
9
9
10
63
62
62
60
53
52
52
50
32
31
31
29

53
60
55

48
54
50

25
33
30
I
[A]
1.40
1.50
1.60
1.80
0.60
0.60
0.60
0.70
0.10
0.20
0.20
0.20
207
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Tach output
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60950-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
Approvals: VDE, UL, CSA, CCC, GOST are applied for
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 315-AA76 -01
A3G 315-AA76 -02
W3G315-CA76 -01
W3G315-CA76 -02
S3G 315-BA76 -01
S3G 315-BA76 -02
S3G 315-AA76 -01
S3G 315-AA76 -02
A3G 315-AA58 -01
A3G 315-AA58 -02
W3G315-CA58 -01
W3G315-CA58 -02
S3G 315-BA58 -01
S3G 315-BA58 -02
S3G 315-AA58 -01
S3G 315-AA58 -02
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
[CFM] 0
[
P
a
]
[
i
n

H
2
O
]
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
600 1200 1800 2400
400 800 1200
B
3
4
2
9
10
11
12
6
5 1
7
8
[m
3
/h]
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 208 f.
Electr. connection
p. 423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1660
1640
1625
1610
1250
1250
1220
1170
640
630
630
620
110
119
125
135
50
55
55
57
11
12
12
13
62
61
62
60
55
54
54
52
35
34
34
33

43
52
50

24
40
43

17
31
37
I
[A]
0.80
0.90
0.90
1.00
1.00
1.00
1.00
1.00
0.40
0.40
0.50
0.50
208
EC axial fans mains-powered
S series, 315, drawings of directions of air flow "V" and "A"
105,21
c3
32,50,5
30,2
853
4
5
0
+
2
0
8
5
8

1
3
3

0
,
3

1
1
5
,
3

3
1
2

9
2
,
1

1
2
5

9
0

5
8
4
x
9
0

4
5

M4
M4
M4
Without attachments
Type
c
A3G 315-AA76 -01
A3G 315-AA76 -02
A3G 315-AA58 -01
A3G 315-AA58 -02
6.0
-6.0
6.0
-6.0
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G315-CA76 -01
W3G315-CA76 -02
W3G315-CA58 -01
W3G315-CA58 -02
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
s
S3G 315-BA76 -01
S3G 315-BA76 -02
S3G 315-BA58 -01
S3G 315-BA58 -02
91.0
79.0
91.0
79.0
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
(1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm
(1)
(2)
(3)
209
With guard grille for short nozzle
Type
u
S3G 315-AA76 -01
S3G 315-AA76 -02
S3G 315-AA58 -01
S3G 315-AA58 -02
41.0
29.0
41.0
29.0
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1630 170 1.30 120 -25 to +60 2.9 J1)
210
EC axial fans mains-powered
S series, 330
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 330 M3G074-CF
*3G 330 M3G074-CF
subject to alterations
0
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
[m
3
/h]
[CFM]
1000
1000 1500 500
2000 3000
2000
A
3
4
2
9
10
11
12
6
5 1
7
8
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1660 170 2.20 120 -25 to +60 2.9 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 423
J1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1660
1630
1610
1570
1350
1340
1330
1290
830
820
810
800
131
144
147
163
72
83
87
92
20
23
25
27
68
66
64
63
64
62
60
58
51
48
45
44

81
78
61

80
74
62

63
59
48
I
[A]
1.70
1.80
1.90
2.10
1.00
1.10
1.20
1.20
0.30
0.30
0.40
0.40
211
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Tach output
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60950-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
Approvals: VDE, UL, CSA, CCC, GOST are applied for
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 330-AA76 -01
A3G 330-AA76 -02
W3G330-CA76 -01
W3G330-CA76 -02
S3G 330-BA76 -01
S3G 330-BA76 -02
S3G 330-AA76 -01
S3G 330-AA76 -02
A3G 330-AA58 -01
A3G 330-AA58 -02
W3G330-CA58 -01
W3G330-CA58 -02
S3G 330-BA58 -01
S3G 330-BA58 -02
S3G 330-AA58 -01
S3G 330-AA58 -02
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
0
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
[m
3
/h]
[CFM]
1000
1000 1500 500
2000 3000
2000
B
3
4
2
9
10
11
12
6
5 1
7
8
[
P
a
]
[
i
n

H
2
O
]
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 212 f.
Electr. connection
p. 423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1630
1600
1590
1580
1350
1330
1330
1310
970
960
960
950
130
139
146
151
76
82
86
93
33
36
37
40
68
65
64
63
63
61
60
58
54
52
50
49

70
67
60

72
69
59

74
70
60
I
[A]
0.95
1.00
1.10
1.10
0.60
0.60
0.65
0.70
0.30
0.30
0.30
0.30
212
EC axial fans mains-powered
S series, 330, drawings of directions of air flow "V" and "A"
105,21
c3
32,50,5
30,2
873
4
5
0
+
2
0
8
5
8

1
3
3

0
,
3

1
1
5
,
3

3
3
0

9
2
,
1

1
2
5

9
0

5
8
4
x
9
0

4
5

M4
M4
M4
Without attachments
Type
c
A3G 330-AA76 -01
A3G 330-AA76 -02
A3G 330-AA58 -01
A3G 330-AA58 -02
6.0
-7.0
6.0
-7.0
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G330-CA76 -01
W3G330-CA76 -02
W3G330-CA58 -01
W3G330-CA58 -02
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
s
S3G 330-BA76 -01
S3G 330-BA76 -02
S3G 330-BA58 -01
S3G 330-BA58 -02
93.0
80.0
93.0
80.0
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
(1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm
(1)
(2)
(3)
213
With guard grille for short nozzle
Type
u
S3G 330-AA76 -01
S3G 330-AA76 -02
S3G 330-AA58 -01
S3G 330-AA58 -02
43.0
30.0
43.0
30.0
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1540 170 1.30 100 -25 to +60 2.9 J1)
214
EC axial fans mains-powered
S series, 350
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 350 M3G074-CF
*3G 350 M3G074-CF
subject to alterations
0
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
[m
3
/h]
[CFM]
1000
1000 1500 500
2000 3000
2000
A
3
4
2
9
10
11
12
6
5 1
7
8
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1600 170 2.20 100 -25 to +60 2.9 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 423
J1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1600
1540
1490
1410
1300
1250
1210
1150
910
880
850
820
165
167
167
167
91
91
92
91
36
35
35
35
66
66
64
61
62
61
59
55
54
52
50
46

68
72
60

68
70
59

62
64
55
I
[A]
2.10
2.10
2.10
2.10
1.20
1.20
1.20
1.20
0.50
0.50
0.50
0.50
215
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Tach output
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60950-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
Approvals: VDE, UL, CSA, CCC, GOST are applied for
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 350-AA76 -01
A3G 350-AA76 -02
W3G350-CA76 -01
W3G350-CA76 -02
S3G 350-BA76 -01
S3G 350-BA76 -02
S3G 350-AA76 -01
S3G 350-AA76 -02
A3G 350-AA58 -01
A3G 350-AA58 -02
W3G350-CA58 -01
W3G350-CA58 -02
S3G 350-BA58 -01
S3G 350-BA58 -02
S3G 350-AA58 -01
S3G 350-AA58 -02
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
0
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
0
,
2
[m
3
/h]
[CFM]
1000
1000 1500 500
2000 3000
2000
B
3
4
2
9
10
11
12
6
5 1
7
8
[
P
a
]
[
i
n

H
2
O
]
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 f.
Drawings
p. 216 f.
Electr. connection
p. 423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1540
1520
1490
1430
1260
1240
1200
1150
870
850
840
810
150
162
168
167
87
91
90
91
33
35
34
34
67
66
64
61
61
60
58
55
51
50
48
45

62
66
61

60
64
57

58
63
57
I
[A]
1.20
1.20
1.30
1.20
0.70
0.70
0.70
0.70
0.30
0.30
0.30
0.30
216
EC axial fans mains-powered
S series, 350, drawings of directions of air flow "V" and "A"
105,21
c3
32,50,5
30,2
923
4
5
0
+
2
0
8
5
8

1
3
3

0
,
3

1
1
5
,
3

3
5
2

9
2
,
1

1
2
5

9
0

5
8
4
x
9
0

4
5

M4
M4
M4
Without attachments
Type
c
A3G 350-AA76 -01
A3G 350-AA76 -02
A3G 350-AA58 -01
A3G 350-AA58 -02
7.0
-12.0
7.0
-12.0
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G350-CA76 -01
W3G350-CA76 -02
W3G350-CA58 -01
W3G350-CA58 -02
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
s
S3G 350-BA76 -01
S3G 350-BA76 -02
S3G 350-BA58 -01
S3G 350-BA58 -02
99.0
80.0
99.0
80.0
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
(1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm
(1)
(2)
(3)
217
With guard grille for short nozzle
Type
u
S3G 350-AA76 -01
S3G 350-AA76 -02
S3G 350-AA58 -01
S3G 350-AA58 -02
49.0
30.0
49.0
30.0
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1690 390 2.50 180 -25 to +60 5.2 K1)
218
EC axial fans mains-powered
S series, 400
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 400 M3G084-FA
*3G 400 M3G084-FA
subject to alterations
1000 2000 3000 4000 5000
0 2000 [CFM] 1000
[
P
a
]
50
25
100
125
150
175
75
0
,
2
5
[
i
n

H
2 O
]
0
,
5
[m
3
/h]
3000
A
3
4
2
1
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1620 350 4.20 165 -25 to +60 5.2 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 425
K1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1620
1590
1565
1550
310
332
349
350
69
68
68
68

66
62
54
I
[A]
3.80
4.00
4.20
4.20
219
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Alarm relay
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 61800-5-1, CE
Approvals: UL, CSA; VDE, CCC, GOST are applied for B A B
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 400-AA37 -81
A3G 400-AA37 -82
W3G400-CA37 -81
W3G400-CA37 -82
S3G 400-KA37 -81
S3G 400-KA37 -82
S3G 400-LA37 -81
S3G 400-LA37 -82
A3G 400-AA22 -71
A3G 400-AA22 -72
W3G400-CA22 -71
W3G400-CA22 -72
S3G 400-KA22 -71
S3G 400-KA22 -72
S3G 400-LA22 -71
S3G 400-LA22 -72
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000 5000
0 1000
[
P
a
]
50
100
150
0
,
2
5
[
i
n

H
2 O
]
0
,
5
[m
3
/h]
3000 2000 [CFM]
B
3
4
2
9
10
11
12
6
5 1
7
8
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 ff.
Drawings
p. 220 f.
Electr. connection
p. 425
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1690
1660
1640
1630
1300
1300
1300
1300
1000
1000
1000
1000
340
375
380
390
162
179
192
203
76
91
93
100
75
72
70
68
68
66
64
63
61
60
57
56

64
61
54

64
61
54

64
61
54
I
[A]
2.10
2.30
2.40
2.50
1.00
1.10
1.20
1.20
0.50
0.60
0.60
0.70
220
EC axial fans mains-powered
S series, 400, drawings of directions of air flow "V" and "A"
Without attachments
Type
A3G 400-AA37 -81
A3G 400-AA37 -82
A3G 400-AA22 -71
A3G 400-AA22 -72
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G400-CA37 -81
W3G400-CA37 -82
W3G400-CA22 -71
W3G400-CA22 -72
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
S3G 400-KA37 -81
S3G 400-KA37 -82
S3G 400-KA22 -71
S3G 400-KA22 -72
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
Depth of screw 8-10 mm
221
With guard grille for short nozzle
Type
S3G 400-LA37 -81
S3G 400-LA37 -82
S3G 400-LA22 -71
S3G 400-LA22 -72
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
1~ 200-277 50/60 1310 325 2.10 120 -25 to +60 5.5 K1)
222
EC axial fans mains-powered
S series, 450
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*3G 450 M3G084-FA
*3G 450 M3G084-FA
subject to alterations
1000 2000 3000 4000 5000
0 2000 1000
[
P
a
]
[
i
n

H
2 O
]
[m
3
/h]
3000
50
25
100
125
150
175
75
0
,
2
5
0
,
5
[CFM]
A
3
4
2
1
Curves
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
VAC Hz rpm W A Pa C kg
1~ 100-130 50/60 1270 310 3.70 120 -25 to +60 5.5 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

w
i
t
h
o
u
t

a
t
t
a
c
h
m
e
n
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 425
K1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1270
1245
1230
1220
267
282
300
308
69
69
67
63

70
66
42
I
[A]
3.30
3.50
3.70
3.70
223
Technical features: Output 10 VDC max. 1.1 mA
PFC (passive) Alarm relay
Control input 0-10 VDC / PWM Over-temperature protected electronics / motor
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 61800-5-1, CE
Approvals: UL, CSA; VDE, CCC, GOST are applied for B A B
Without
attachments
With guard grille
for full nozzle
With full
round nozzle
With guard grille
for short nozzle
"V" A3G 450-AA40 -81
A3G 450-AA40 -82
W3G450-CA40 -81
W3G450-CA40 -82
S3G 450-KA40 -81
S3G 450-KA40 -82
S3G 450-LA40 -81
S3G 450-LA40 -82
A3G 450-AA14 -71
A3G 450-AA14 -72
W3G450-CA14 -71
W3G450-CA14 -72
S3G 450-KA14 -71
S3G 450-KA14 -72
S3G 450-LA14 -71
S3G 450-LA14 -72
"A"
"V"
"A"
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
1000 2000 3000 4000 5000
0 1000
[
P
a
]
40
120
160
200
80
0
,
4
[
i
n

H
2 O
]
0
,
2
0
,
6
[m
3
/h]
3000 2000 [CFM]
B
3
4
2
9
10
11
12
6
5 1
7
8
Curves
"V"/ "A" U "V"/ "A" U "V"/ "A" U "V"/ "A" U
Wall ring
p. 372 f.
Guard grille
p. 362 ff.
Drawings
p. 224 f.
Electr. connection
p. 425
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[W]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1310
1290
1270
1240
1000
1000
1000
1000
700
700
700
700
245
262
290
325
108
122
140
174
38
42
48
60
73
72
70
66
68
67
65
61
61
60
58
56

70
66
42

70
66
42

70
66
42
I
[A]
1.50
1.70
1.90
2.10
0.70
0.80
0.90
1.10
0.30
0.30
0.30
0.40
224
EC axial fans mains-powered
S series, 450, drawings of directions of air flow "V" and "A"
Without attachments
Type
A3G 450-AA40 -81
A3G 450-AA40 -82
A3G 450-AA14 -71
A3G 450-AA14 -72
"V"
"A"
"V"
"A"
With full round nozzle
Type
W3G450-CA40 -81
W3G450-CA40 -82
W3G450-CA14 -71
W3G450-CA14 -72
"V"
"A"
"V"
"A"
With guard grille for full nozzle
Type
S3G 450-KA40 -81
S3G 450-KA40 -82
S3G 450-KA14 -71
S3G 450-KA14 -72
"V"
"A"
"V"
"A"
"V"
"A" U
"V"
"A" U
"V"
"A" U
Core-end sleeve
Depth of screw 8-10 mm
225
With guard grille for short nozzle
Type
S3G 450-LA40 -81
S3G 450-LA40 -82
S3G 450-LA14 -71
S3G 450-LA14 -72
"V"
"A"
"V"
"A"
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
"A" U
226
EC axial fans mains-powered
S series, 500
Nominal data
Type Motor
*3G 500 M3G112-GA
subject to alterations
2000
1000
4000 6000 8000 10000
2000 3000 4000 5000 6000
[m
3
/h]
[CFM] 0
40
80
120
160
200
0
,
2
0
,
4
0
,
6
2
6
7
8
10
11
12
9
3
1 5
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 230 VAC
VAC Hz rpm kW A Pa C
1~ 200-277 50/60 1250 0.69 3.10 110 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1260
1260
1250

1020
1030
1020
1020
750
740
740
740
0.61
0.67
0.69

0.41
0.36
0.37
0.36
0.16
0.15
0.15
0.15
74
76
77

80
70
71
73
70
62
62
63

62
60

67
67
63

73
72
68
I
[A]
2.80
3.00
3.10

1.90
1.70
1.70
1.70
0.80
0.70
0.70
0.70
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
227
Drawings
p. 230 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage detection
PFC (active) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 500-AE33 -11 W3G500-CE33 -11 S3G 500-BE33 -11 S3G 500-AE33 -11
3~ 380-480 50/60 1450 1.04 1.70 195 -25 to +60 L2)
228
EC axial fans mains-powered
S series, 500
Nominal data
Type Motor
*3G 500 M3G112-GA
*3G 500 M3G112-GA
subject to alterations
2000
1000
4000 6000 8000 10000
2000 3000 4000 5000 6000
[m
3
/h]
[CFM] 0
40
80
120
160
200
0
,
2
0
,
4
0
,
6
2
6
7
8
10
11
12
9
3
4
1 5
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1450 1.04 3.40 195 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L2)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1450
1450
1450
1450
1220
1270
1260
1260
1080
1110
1110
1100
1.21
1.00
1.05
1.04
0.70
0.66
0.67
0.66
0.47
0.44
0.46
0.45
97
79
81
82
87
76
77
79
83
73
74
75

77
68
60

81
73
62

81
72
63
I
[A]
3.80
3.20
3.40
3.40
2.40
2.20
2.40
2.20
1.80
1.80
1.80
1.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
229
2000
1000
4000 6000 8000 10000
2000 3000 4000 5000 6000
[m
3
/h]
[CFM] 0
40
80
120
160
200
0
,
2
0
,
4
0
,
6
2
6
7
8
10
11
12
9
3
4
1 5
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 230 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1450
1450
1450
1450
1220
1270
1260
1260
1080
1110
1110
1100
1.21
1.00
1.05
1.04
0.70
0.66
0.67
0.66
0.47
0.44
0.46
0.45
97
79
81
82
87
76
77
79
83
73
74
75

77
68
60

81
73
62

81
72
63
I
[A]
1.90
1.60
1.70
1.70
1.20
1.10
1.20
1.10
0.90
0.90
0.90
0.90
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 500-AE33 -01 W3G500-CE33 -01 S3G 500-BE33 -01 S3G 500-AE33 -01
"V" A3G 500-AE38 -06 W3G500-CE38 -06 S3G 500-BE38 -06 S3G 500-AE38 -06
B
230
EC axial fans mains-powered
S series, 500, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 500-AE33 -11
A3G 500-AE38 -06
A3G 500-AE33 -01
8.7
8.7
8.7
With full square nozzle
Type Mass
[kg]
W3G500-CE33 -11
W3G500-CE38 -06
W3G500-CE33 -01
16.2
16.2
16.2
With guard grille for full nozzle
Type Mass
[kg]
S3G 500-BE33 -11
S3G 500-BE38 -06
S3G 500-BE33 -01
11.2
11.2
11.2
"V"
Cable gland
Depth of screw
12-16 mm
"V"
"V"
231
With guard grille for short nozzle
Type Mass
[kg]
S3G 500-AE33 -11
S3G 500-AE38 -06
S3G 500-AE33 -01
12.4
12.4
12.4
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
232
EC axial fans mains-powered
S series, 560
Nominal data
Type Motor
*3G 560 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
200
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 230 VAC
VAC Hz rpm kW A Pa C
1~ 200-277 50/60 1160 0.79 3.50 155 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1160
1160
1150
1160
970
950
930
940
680
690
680
680
0.66
0.73
0.77
0.79
0.35
0.39
0.40
0.41
0.14
0.16
0.17
0.17
77
80
80
80
73
75
74
74
67
67
65
66

82
74
65

92
82
72

96
88
76
I
[A]
3.00
3.30
3.40
3.50
1.60
1.80
1.80
1.90
0.70
0.80
0.80
0.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
233
Drawings
p. 236 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage detection
PFC (active) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 560-AE41 -11 W3G560-CE41 -11 S3G 560-BE41 -11 S3G 560-AE41 -11
3~ 380-480 50/60 1260 0.97 1.60 180 -25 to +60 L2)
234
EC axial fans mains-powered
S series, 560
Nominal data
Type Motor
*3G 560 M3G112-GA
*3G 560 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
200
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1260 0.97 3.20 180 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L2)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1260
1260
1260
1260
1080
1060
1050
1040
800
790
780
780
0.81
0.92
0.96
0.97
0.50
0.53
0.54
0.54
0.22
0.24
0.24
0.24
77
80
81
83
73
75
76
78
67
68
69
69

75
65
58

80
71
63

86
75
66
I
[A]
2.80
3.20
3.20
3.20
2.00
2.00
2.00
2.00
1.00
1.00
1.00
1.00
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
235
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
200
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 236 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1260
1260
1260
1260
1080
1060
1050
1040
800
790
780
780
0.81
0.92
0.96
0.97
0.50
0.53
0.54
0.54
0.22
0.24
0.24
0.24
77
80
81
83
73
75
76
78
67
68
69
69

75
65
58

80
71
63

86
75
66
I
[A]
1.40
1.60
1.60
1.60
1.00
1.00
1.00
1.00
0.50
0.50
0.50
0.50
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 560-AE32 -01 W3G560-CE32 -01 S3G 560-BE32 -01 S3G 560-AE32 -01
"V" A3G 560-AE43 -06 W3G560-CE43 -06 S3G 560-BE43 -06 S3G 560-AE43 -06
B
236
EC axial fans mains-powered
S series, 560, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 560-AE41 -11
A3G 560-AE43 -06
A3G 560-AE32 -01
8.9
8.9
8.9
With full square nozzle
Type Mass
[kg]
W3G560-CE41 -11
W3G560-CE43 -06
W3G560-CE32 -01
18.0
18.0
18.0
With guard grille for full nozzle
Type Mass
[kg]
S3G 560-BE41 -11
S3G 560-BE43 -06
S3G 560-BE32 -01
11.9
11.9
11.9
"V"
Cable gland
Depth of screw
12-16 mm
"V"
"V"
237
With guard grille for short nozzle
Type Mass
[kg]
S3G 560-AE41 -11
S3G 560-AE43 -06
S3G 560-AE32 -01
13.6
13.6
13.6
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
238
EC axial fans mains-powered
S series, 630
Nominal data
Type Motor
*3G 630 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 230 VAC
VAC Hz rpm kW A Pa C
1~ 200-277 50/60 970 0.73 3.30 135 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
970
970
960
970
750
750
750
750
540
540
540
540
0.55
0.66
0.69
0.73
0.25
0.30
0.32
0.33
0.11
0.13
0.14
0.14
74
76
77
79
68
70
71
72
61
63
63
63

88
79
68

92
83
70

92
85
71
I
[A]
2.60
3.00
3.20
3.30
1.20
1.40
1.50
1.60
0.70
0.70
0.60
0.70
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
239
Drawings
p. 242 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage detection
PFC (active) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 630-AE37 -11 W3G630-CE37 -11 S3G 630-BE37 -11 S3G 630-AE37 -11
3~ 380-480 50/60 1010 0.83 1.50 150 -25 to +60 L2)
240
EC axial fans mains-powered
S series, 630
Nominal data
Type Motor
*3G 630 M3G112-GA
*3G 630 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1010 0.83 3.00 150 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L2)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1010
1010
1010
1010
920
900
880
860
680
680
660
650
0.62
0.74
0.78
0.83
0.45
0.51
0.49
0.51
0.20
0.22
0.22
0.23
75
77
78
79
73
75
75
76
66
67
67
68

87
77
65

92
83
68

49
91
74
I
[A]
2.20
2.60
2.80
3.00
1.80
2.00
1.80
2.00
0.80
1.00
1.00
1.00
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
241
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
40
80
160
120
0
,
2
0
,
4
0
,
6
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 242 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1010
1010
1010
1010
920
900
880
860
680
680
660
650
0.62
0.74
0.78
0.83
0.45
0.51
0.49
0.51
0.20
0.22
0.22
0.23
75
77
78
79
73
75
75
76
66
67
67
68

87
77
65

92
83
68

49
91
74
I
[A]
1.10
1.30
1.40
1.50
0.90
1.00
0.90
1.00
0.40
0.50
0.50
0.50
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 630-AE31 -01 W3G630-CE31 -01 S3G 630-BE31 -01 S3G 630-AE31 -01
"V" A3G 630-AE42 -06 W3G630-CE42 -06 S3G 630-BE42 -06 S3G 630-AE42 -06
B
242
EC axial fans mains-powered
S series, 630, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 630-AE37 -11
A3G 630-AE42 -06
A3G 630-AE31 -01
9.1
9.1
9.1
With full square nozzle
Type Mass
[kg]
W3G630-CE37 -11
W3G630-CE42 -06
W3G630-CE31 -01
20.4
20.4
20.4
With guard grille for full nozzle
Type Mass
[kg]
S3G 630-BE37 -11
S3G 630-BE42 -06
S3G 630-BE31 -01
12.8
12.8
12.8
"V"
Cable gland
Depth of screw
12-16 mm
"V"
"V"
243
With guard grille for short nozzle
Type Mass
[kg]
S3G 630-AE37 -11
S3G 630-AE42 -06
S3G 630-AE31 -01
14.6
14.6
14.6
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
3~ 380-480 50/60 1220 1.70 2.60 215 -25 to +60 M)
244
EC axial fans mains-powered
S series, 630
Nominal data
Type Motor
*3G 630 M3G150-FF
*3G 630 M3G150-FF
subject to alterations
4000 8000 12000 16000
0 2500 5000
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
160
180
200
220
0
,
2
0
,
4
0
,
8
0
,
6
2
3
6
1 5
4
7
8
9
10
11
12
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1220 1.70 5.20 215 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1220
1220
1220
1220
1100
1100
1100
1100
980
980
980
980
1.30
1.52
1.60
1.70
0.95
1.11
1.18
1.24
0.67
0.79
0.83
0.88
77
76
78
81
75
74
76
79
72
72
73
76

77
70
58

77
70
58

77
70
58
I
[A]
4.00
4.80
5.00
5.20
3.00
3.60
3.60
3.80
2.20
2.40
2.60
2.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
245
4000 8000 12000 16000
0 2500 5000
[
P
a
]
[
i
n

H
2
O
]
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
160
180
200
220
0
,
2
0
,
4
0
,
8
0
,
6
2
3
6
1 5
4
7
8
9
10
11
12
Curves
Drawings
p. 248 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1220
1220
1220
1220
1100
1100
1100
1100
980
980
980
980
1.30
1.52
1.60
1.70
0.95
1.11
1.18
1.24
0.67
0.79
0.83
0.88
77
76
78
81
75
74
76
79
72
72
73
76

77
70
58

77
70
58

77
70
58
I
[A]
2.00
2.40
2.50
2.60
1.50
1.80
1.80
1.90
1.10
1.20
1.30
1.40
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
A3G 630-AG12 -13
A3G 630-AG12 -14
W3G630-CG12 -13
W3G630-CG12 -14
S3G 630-BG12 -13

S3G 630-AG12 -13

S3G 630-CG12 -14


"A"
"V"
A3G 630-AG08 -03
A3G 630-AG08 -04
W3G630-CG08 -03
W3G630-CG08 -04
S3G 630-BG08 -03

S3G 630-AG08 -03

S3G 630-CG08 -04


"A"
B
3~ 380-480 50/60 1490 3.10 4.70 340 -25 to +60 M)
246
EC axial fans mains-powered
S series, 630
Nominal data
Type Motor
*3G 630 M3G150-IF
*3G 630 M3G150-IF
subject to alterations
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
120
160
200
240
280
320
0
,
4
0
,
6
0
,
8
1
,
0
2
3
0
,
2
1
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1490 3.10 9.40 340 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1490
1490
1490
1490
1400
1400
1400
1400
1300
1300
1300
1300
2.35
2.77
2.94
3.10
1.95
2.30
2.44
2.55
1.56
1.84
1.95
2.04
82
82
84
87
80
80
83
85
79
79
81
84

74
64
55

74
64
55

74
64
55
I
[A]
7.20
8.40
9.00
9.40
6.00
7.00
7.40
7.80
4.80
5.60
6.00
6.20
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
A3G 630-AH07 -13
A3G 630-AH07 -14
W3G630-CH07 -13
W3G630-CH07 -14
S3G 630-BH07 -13

S3G 630-AH07 -13

S3G 630-CH07 -14


A3G 630-AH02 -03
A3G 630-AH02 -04
W3G630-CH02 -03
W3G630-CH02 -04
S3G 630-BH02 -03

S3G 630-AH02 -03

S3G 630-CH02 -04


247
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
120
160
200
240
280
320
0
,
4
0
,
6
0
,
8
1
,
0
2
3
0
,
2
1
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 248 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1490
1490
1490
1490
1400
1400
1400
1400
1300
1300
1300
1300
2.35
2.77
2.94
3.10
1.95
2.30
2.44
2.55
1.56
1.84
1.95
2.04
82
82
84
87
80
80
83
85
79
79
81
84

74
64
55

74
64
55

74
64
55
I
[A]
3.60
4.20
4.50
4.70
3.00
3.50
3.70
3.90
2.40
2.80
3.00
3.10
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
248
EC axial fans mains-powered
S series, 630, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 630-AG08 -03
A3G 630-AG12 -13
A3G 630-AH02 -03
A3G 630-AH07 -13
23.0
23.0
26.0
26.0
With full square nozzle
Type Mass
[kg]
W3G630-CG08 -03
W3G630-CG12 -13
W3G630-CH02 -03
W3G630-CH07 -13
38.0
38.0
41.0
41.0
With guard grille for full nozzle
Type Mass
[kg]
S3G 630-BG08 -03
S3G 630-BG12 -13
S3G 630-BH02 -03
S3G 630-BH07 -13
27.5
27.5
30.5
30.5
"V"
Cable gland
Depth of screw
20-25 mm
"V"
"V"
15
7
,
692
1
0
2
5
68
View X
249
With guard grille for short nozzle
Type Mass
[kg]
S3G 630-AG08 -03
S3G 630-AG12 -13
S3G 630-AH02 -03
S3G 630-AH07 -13
26.5
26.5
29.5
29.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
250
EC axial fans mains-powered
S series, 630, drawings for direction of air flow "A"
Without attachments
Type Mass
[kg]
A3G 630-AG08 -04
A3G 630-AG12 -14
A3G 630-AH02 -04
A3G 630-AH07 -14
23.0
23.0
26.0
26.0
With full square nozzle
Type Mass
[kg]
W3G630-CG08 -04
W3G630-CG12 -14
W3G630-CH02 -04
W3G630-CH07 -14
39.0
39.0
42.0
42.0
With guard grille for full nozzle
Type Mass
[kg]
S3G 630-CG08 -04
S3G 630-CG12 -14
S3G 630-CH02 -04
S3G 630-CH07 -14
28.5
28.5
31.5
31.5
"A" U
Cable gland
Depth of screw
20-25 mm
"A" U
"A" U
251
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
252
EC axial fans mains-powered
S series, 650
Nominal data
Type Motor
*3G 650 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
20
40
60
80
120
140
100
0
,
2
0
,
4
2
5
6
7
8
10
11
12
9
3
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 230 VAC
VAC Hz rpm kW A Pa C
1~ 200-277 50/60 890 0.66 3.00 90 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L1)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
910
900
890

830
830
820
810
650
640
640
630
0.55
0.63
0.66

0.41
0.48
0.49
0.51
0.19
0.23
0.24
0.25
76
77
79

73
75
76
76
67
68
69
70

90
78

91
84
65

95
86
67
I
[A]
2.50
2.90
3.00

1.90
2.20
2.30
2.30
0.90
1.10
1.10
1.20
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
253
Drawings
p. 256 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage detection
PFC (active) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 650-AE34 -11 W3G650-CE34 -01 S3G 650-BE34 -11 S3G 650-AE34 -11
3~ 380-480 50/60 910 0.72 1.30 125 -25 to +60 L2)
254
EC axial fans mains-powered
S series, 650
Nominal data
Type Motor
*3G 650 M3G112-GA
*3G 650 M3G112-GA
subject to alterations
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
20
40
60
80
120
140
100
0
,
2
0
,
4
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 910 0.72 2.60 125 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 427
L2)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
910
910
910
910
830
810
790
790
630
620
600
610
0.53
0.62
0.66
0.72
0.39
0.43
0.43
0.46
0.17
0.19
0.19
0.21
75
77
78
79
73
74
74
75
66
67
67
67

87
74
60

91
79
62

94
83
63
I
[A]
1.80
2.20
2.40
2.60
1.60
1.60
1.60
1.80
0.80
0.80
0.80
0.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
255
2000 4000 6000 8000 10000 12000
0 2000 4000 [CFM]
[m
3
/h]
6000
20
40
60
80
120
140
100
0
,
2
0
,
4
2
5
6
7
8
10
11
12
9
3
4
1
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 256 f.
Electr. connection
p. 427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
910
910
910
910
830
810
790
790
630
620
600
610
0.53
0.62
0.66
0.72
0.39
0.43
0.43
0.46
0.17
0.19
0.19
0.21
75
77
78
79
73
74
74
75
66
67
67
67

87
74
60

91
79
62

94
83
63
I
[A]
0.90
1.10
1.20
1.30
0.80
0.80
0.80
0.90
0.40
0.40
0.40
0.40
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST; CCC is applied for
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V" "V" "V" "V"
"V" A3G 650-AE35 -01 W3G650-CE35 -01 S3G 650-BE35 -01 S3G 650-AE35 -01
"V" A3G 650-AE44 -06 W3G650-CE44 -06 S3G 650-BE44 -06 S3G 650-AE44 -08
B
256
EC axial fans mains-powered
S series, 650, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 650-AE34 -11
A3G 650-AE44 -06
A3G 650-AE35 -01
9.2
9.2
9.2
With full square nozzle
Type Mass
[kg]
W3G650-CE34 -01
W3G650-CE44 -06
W3G650-CE35 -01
21.5
21.5
21.5
With guard grille for full nozzle
Type Mass
[kg]
S3G 650-BE34 -11
S3G 650-BE44 -06
S3G 650-BE35 -01
13.1
13.1
13.1
"V"
Cable gland
Depth of screw
12-16 mm
"V"
"V"
257
With guard grille for short nozzle
Type Mass
[kg]
S3G 650-AE34 -11
S3G 650-AE44 -08
S3G 650-AE35 -01
14.7
14.7
14.7
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
3~ 380-480 50/60 1250 1.65 2.60 240 -25 to +60 M)
258
EC axial fans mains-powered
S series, 650
Nominal data
Type Motor
*3G 650 M3G150-FF
*3G 650 M3G150-FF
subject to alterations
4000 8000 12000 16000
0 2500 5000
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
160
180
200
220
240
0
,
2
0
,
4
0
,
8
0
,
6
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1250 1.65 5.20 240 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1250
1250
1250
1250
1100
1100
1100
1100
950
950
950
950
1.07
1.38
1.52
1.65
0.73
0.94
1.03
1.12
0.47
0.60
0.67
0.72
78
78
80
83
76
75
77
80
72
72
74
77

82
71
59

82
71
59

82
71
59
I
[A]
3.20
4.20
4.60
5.20
2.20
2.80
3.20
3.40
1.40
1.80
2.00
2.20
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
-5
-5
B
l
a
d
e

a
n
g
l
e
A
A3G 650-AJ12 -13
A3G 650-AJ12 -14
W3G650-CJ12 -13
W3G650-CJ12 -14
S3G 650-BJ12 -13

S3G 650-CJ12 -14


A3G 650-AJ08 -03
A3G 650-AJ08 -04
W3G650-CJ08 -03
W3G650-CJ08 -04
S3G 650-BJ08 -03

S3G 650-CJ08 -04


259
4000 8000 12000 16000
0 2500 5000
[m
3
/h]
[CFM] 10000 7500
20
40
60
80
120
100
140
160
180
200
220
240
0
,
2
0
,
4
0
,
8
0
,
6
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 262 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1250
1250
1250
1250
1100
1100
1100
1100
950
950
950
950
1.07
1.38
1.52
1.65
0.73
0.94
1.03
1.12
0.47
0.60
0.67
0.72
78
78
80
83
76
75
77
80
72
72
74
77

82
71
59

82
71
59

82
71
59
I
[A]
1.60
2.10
2.30
2.60
1.10
1.40
1.60
1.70
0.70
0.90
1.00
1.10
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
3~ 380-480 50/60 1500 2.87 4.40 350 -25 to +60 M)
260
EC axial fans mains-powered
S series, 650
Nominal data
Type Motor
*3G 650 M3G150-IF
*3G 650 M3G150-IF
subject to alterations
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
120
160
200
240
280
320
360
0
,
4
0
,
6
0
,
8
1
,
0
2
3
0
,
2
1
,
2
1
,
4
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1500 2.87 8.80 350 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1500
1500
1500
1500
1350
1350
1350
1350
1200
1200
1200
1200
1.86
2.37
2.65
2.87
1.35
1.73
1.93
2.09
0.95
1.21
1.35
1.47
82
82
84
87
80
80
82
85
78
77
79
82

82
70
59

82
70
59

82
70
59
I
[A]
5.60
7.20
8.00
8.80
4.20
5.20
5.80
6.40
3.00
3.60
4.20
4.40
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
-5
-5
B
l
a
d
e

a
n
g
l
e
A
A3G 650-AK07 -13
A3G 650-AK07 -14
W3G650-CK07 -13
W3G650-CK07 -14
S3G 650-BK07 -13

S3G 650-CK07 -14


A3G 650-AK02 -03
A3G 650-AK02 -04
W3G650-CK02 -03
W3G650-CK02 -04
S3G 650-BK02 -03

S3G 650-CK02 -04


261
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
120
160
200
240
280
320
360
0
,
4
0
,
6
0
,
8
1
,
0
2
3
0
,
2
1
,
2
1
,
4
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 262 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1500
1500
1500
1500
1350
1350
1350
1350
1200
1200
1200
1200
1.86
2.37
2.65
2.87
1.35
1.73
1.93
2.09
0.95
1.21
1.35
1.47
82
82
84
87
80
80
82
85
78
77
79
82

82
70
59

82
70
59

82
70
59
I
[A]
2.80
3.60
4.00
4.40
2.10
2.60
2.90
3.20
1.50
1.80
2.10
2.20
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
262
EC axial fans mains-powered
S series, 650, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 650-AJ12 -13
A3G 650-AJ08 -03
A3G 650-AK07 -13
A3G 650-AK02 -03
23.5
23.5
26.5
26.5
With full square nozzle
Type Mass
[kg]
W3G650-CJ12 -13
W3G650-CJ08 -03
W3G650-CK07 -13
W3G650-CK02 -03
40.0
40.0
43.0
43.0
With guard grille for full nozzle
Type Mass
[kg]
S3G 650-BJ12 -13
S3G 650-BJ08 -03
S3G 650-BK07 -13
S3G 650-BK02 -03
28.5
28.5
31.5
31.5
"V"
Cable gland
Depth of screw
20-25 mm
"V"
"V"
15
7
,
692
1
0
2
5
68
View X
263
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
264
EC axial fans mains-powered
S series, 650, drawings for direction of air flow "A"
Without attachments
Type Mass
[kg]
A3G 650-AJ12 -14
A3G 650-AJ08 -04
A3G 650-AK07 -14
A3G 650-AK02 -04
23.5
23.5
26.5
26.5
With full square nozzle
Type Mass
[kg]
W3G650-CJ12 -14
W3G650-CJ08 -04
W3G650-CK07 -14
W3G650-CK02 -04
41.0
41.0
44.0
44.0
With guard grille for full nozzle
Type Mass
[kg]
S3G 650-CJ12 -14
S3G 650-CJ08 -04
S3G 650-CK07 -14
S3G 650-CK02 -04
29.5
29.5
32.5
32.5
"A" U
Cable gland
Depth of screw
20-25 mm
"A" U
"A" U
265
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
3~ 380-480 50/60 1050 1.68 2.60 160 -25 to +60 M)
266
EC axial fans mains-powered
S series, 710
Nominal data
Type Motor
*3G 710 M3G150-FF
*3G 710 M3G150-FF
subject to alterations
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
20
60
120
160
100
140
0
,
4
0
,
6
2
3
0
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1050 1.68 5.20 160 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1050
1050
1050
1050
950
950
950
950
850
850
850
850
1.26
1.57
1.63
1.68
0.94
1.17
1.22
1.25
0.67
0.84
0.87
0.90
76
76
77
79
74
74
75
77
72
72
73
74

73
68
63

73
68
63

73
68
63
I
[A]
3.80
4.80
5.00
5.20
2.80
3.60
3.80
3.80
2.00
2.60
2.60
2.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
267
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
20
60
120
160
100
140
0
,
4
0
,
6
2
3
0
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 270 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1050
1050
1050
1050
950
950
950
950
850
850
850
850
1.26
1.57
1.63
1.68
0.94
1.17
1.22
1.25
0.67
0.84
0.87
0.90
76
76
77
79
74
74
75
77
72
72
73
74

73
68
63

73
68
63

73
68
63
I
[A]
1.90
2.40
2.50
2.60
1.40
1.80
1.90
1.90
1.00
1.30
1.30
1.40
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
A3G 710-AG09 -13
A3G 710-AG09 -14
W3G710-CG09 -13
W3G710-CG09 -14
S3G 710-BG09 -13

S3G 710-AG09 -13

S3G 710-CG09 -14


"A"
"V"
A3G 710-AG01 -03
A3G 710-AG01 -04
W3G710-CG01 -03
W3G710-CG01 -04
S3G 710-BG01 -03

S3G 710-AG01 -03

S3G 710-CG01 -04


"A"
B
3~ 380-480 50/60 1240 2.75 4.20 255 -25 to +60 M)
268
EC axial fans mains-powered
S series, 710
Nominal data
Type Motor
*3G 710 M3G150-IF
*3G 710 M3G150-IF
subject to alterations
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
40
80
120
160
200
240
0
,
2
0
,
4
0
,
6
0
,
8
1
,
0
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 1240 2.75 8.50 255 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
1240
1240
1240
1240
1100
1100
1100
1100
960
960
960
960
1.99
2.47
2.59
2.70
1.39
1.72
1.81
1.89
0.92
1.15
1.20
1.25
80
80
81
84
77
77
79
82
74
74
76
79

74
67
61

74
67
61

74
67
61
I
[A]
6.00
7.50
7.80
8.40
4.20
5.20
5.40
5.60
2.80
3.40
3.60
3.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
A3G 710-AH10 -13
A3G 710-AH10 -14
W3G710-CH10 -13
W3G710-CH10 -14
S3G 710-BH10 -13

S3G 710-AH10 -13

S3G 710-CH10 -14


A3G 710-AH06 -03
A3G 710-AH06 -04
W3G710-CH06 -03
W3G710-CH06 -04
S3G 710-BH06 -03

S3G 710-AH06 -03

S3G 710-CH06 -04


269
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
40
80
120
160
200
240
0
,
2
0
,
4
0
,
6
0
,
8
1
,
0
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 270 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
1240
1240
1240
1240
1100
1100
1100
1100
960
960
960
960
1.99
2.47
2.59
2.70
1.39
1.72
1.81
1.89
0.92
1.15
1.20
1.25
80
80
81
84
77
77
79
82
74
74
76
79

74
67
61

74
67
61

74
67
61
I
[A]
3.00
3.70
3.90
4.20
2.10
2.60
2.70
2.80
1.40
1.70
1.80
1.90
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
270
EC axial fans mains-powered
S series, 710, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 710-AG09 -13
A3G 710-AG01 -03
A3G 710-AH10 -13
A3G 710-AH06 -03
24.0
24.0
27.0
27.0
With full square nozzle
Type Mass
[kg]
W3G710-CG09 -13
W3G710-CG01 -03
W3G710-CH10 -13
W3G710-CH06 -03
43.5
43.5
46.5
46.5
With guard grille for full nozzle
Type Mass
[kg]
S3G 710-BG09 -13
S3G 710-BG01 -03
S3G 710-BH10 -13
S3G 710-BH06 -03
29.5
29.5
32.5
32.5
"V"
Cable gland
Depth of screw
20-25 mm
"V"
"V"
15
7
,
692
1
0
2
5
68
View X
271
With guard grille for short nozzle
Type Mass
[kg]
S3G 710-AG09 -13
S3G 710-AG01 -03
S3G 710-AH10 -13
S3G 710-AH06 -03
28.0
28.0
31.0
31.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
272
EC axial fans mains-powered
S series, 710, drawings for direction of air flow "A"
Without attachments
Type Mass
[kg]
A3G 710-AG09 -14
A3G 710-AG01 -04
A3G 710-AH10 -14
A3G 710-AH06 -04
24.0
24.0
27.0
27.0
With full square nozzle
Type Mass
[kg]
W3G710-CG09 -14
W3G710-CG01 -04
W3G710-CH10 -14
W3G710-CH06 -04
44.5
44.5
47.5
47.5
With guard grille for full nozzle
Type Mass
[kg]
S3G 710-CG09 -14
S3G 710-CG01 -04
S3G 710-CH10 -14
S3G 710-CH06 -04
30.5
30.5
33.5
33.5
"A" U
Cable gland
Depth of screw
20-25 mm
"A" U
"A" U
273
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
3~ 380-480 50/60 830 1.35 2.20 155 -25 to +60 M)
274
EC axial fans mains-powered
S series, 800
Nominal data
Type Motor
*3G 800 M3G150-FF
*3G 800 M3G150-FF
subject to alterations
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
20
60
120
160
100
140
0
,
4
0
,
6
2
3
0
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 830 1.35 4.40 155 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
830
830
830
830
750
750
750
750
670
670
670
670
0.88
1.13
1.24
1.35
0.65
0.83
0.91
0.99
0.46
0.60
0.65
0.71
72
70
72
77
69
68
70
75
67
66
68
72

75
67
57

75
67
57

75
67
57
I
[A]
2.80
3.40
3.80
4.40
2.00
2.60
2.80
3.00
1.40
1.80
2.00
2.20
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
275
4000 8000 12000 16000 20000
0 4000 8000
[m
3
/h]
[CFM] 12000
40
80
20
60
120
160
100
140
0
,
4
0
,
6
2
3
0
,
2
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 278 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
830
830
830
830
750
750
750
750
670
670
670
670
0.88
1.13
1.24
1.35
0.65
0.83
0.91
0.99
0.46
0.60
0.65
0.71
72
70
72
77
69
68
70
75
67
66
68
72

75
67
57

75
67
57

75
67
57
I
[A]
1.40
1.70
1.90
2.20
1.00
1.30
1.40
1.50
0.70
0.90
1.00
1.10
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
A3G 800-AG10 -13
A3G 800-AG10 -14
W3G800-CG10 -13
W3G800-CG10 -14
S3G 800-BG10 -13

S3G 800-AG10 -13

S3G 800-CG10 -14


"A"
"V"
A3G 800-AG02 -03
A3G 800-AG02 -04
W3G800-CG02 -03
W3G800-CG02 -04
S3G 800-BG02 -03

S3G 800-AG02 -03

S3G 800-CG02 -04


"A"
B
3~ 380-480 50/60 980 2.20 3.40 230 -25 to +60 M)
276
EC axial fans mains-powered
S series, 800
Nominal data
Type Motor
*3G 800 M3G150-IF
*3G 800 M3G150-IF
subject to alterations
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
40
80
120
160
200
0
,
2
0
,
4
0
,
6
0
,
8
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 980 2.20 6.80 230 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
980
980
980
980
900
900
900
900
820
820
820
820
1.37
1.76
1.93
2.20
1.06
1.36
1.50
1.71
0.80
1.03
1.13
1.30
74
73
76
82
73
72
73
80
71
70
73
78

78
67
52

78
67
52

78
67
52
I
[A]
4.20
5.40
5.80
6.80
3.20
4.20
4.30
5.20
2.40
3.20
3.40
4.00
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
A3G 800-AH12 -13
A3G 800-AH12 -14
W3G800-CH12 -13
W3G800-CH12 -14
S3G 800-BH12 -13

S3G 800-AH12 -13

S3G 800-CH12 -14


A3G 800-AH03 -03
A3G 800-AH03 -04
W3G800-CH03 -03
W3G800-CH03 -04
S3G 800-BH03 -03

S3G 800-AH03 -03

S3G 800-CH03 -04


277
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
40
80
120
160
200
0
,
2
0
,
4
0
,
6
0
,
8
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 278 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
980
980
980
980
900
900
900
900
820
820
820
820
1.37
1.76
1.93
2.20
1.06
1.36
1.50
1.71
0.80
1.03
1.13
1.30
74
73
76
82
73
72
73
80
71
70
73
78

78
67
52

78
67
52

78
67
52
I
[A]
2.10
2.70
2.90
3.40
1.60
2.10
2.30
2.60
1.20
1.60
1.70
2.00
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
278
EC axial fans mains-powered
S series, 800, drawings for direction of air flow "V"
Without attachments
Type Mass
[kg]
A3G 800-AG10 -13
A3G 800-AG02 -03
A3G 800-AH12 -13
A3G 800-AH03 -03
25.0
25.0
28.0
28.0
With full square nozzle
Type Mass
[kg]
W3G800-CG10 -13
W3G800-CG02 -03
W3G800-CH12 -13
W3G800-CH03 -03
46.5
46.5
49.5
49.5
With guard grille for full nozzle
Type Mass
[kg]
S3G 800-BG10 -13
S3G 800-BG02 -03
S3G 800-BH12 -13
S3G 800-BH03 -03
31.5
31.5
34.5
34.5
"V"
Cable gland
Depth of screw
20-25 mm
"V"
"V"
15
7
,
692
1
5
2
5
68
View X
279
With guard grille for short nozzle
Type Mass
[kg]
S3G 800-AG10 -13
S3G 800-AG02 -03
S3G 800-AH12 -13
S3G 800-AH03 -03
30.0
30.0
33.0
33.0
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
280
EC axial fans mains-powered
S series, 800, drawings for direction of air flow "A"
Without attachments
Type Mass
[kg]
A3G 800-AG10 -14
A3G 800-AG02 -04
A3G 800-AH12 -14
A3G 800-AH03 -04
25.0
25.0
28.0
28.0
With full square nozzle
Type Mass
[kg]
W3G800-CG10 -14
W3G800-CG02 -04
W3G800-CH12 -14
W3G800-CH03 -04
47.5
47.5
50.5
50.5
With guard grille for full nozzle
Type Mass
[kg]
S3G 800-CG10 -14
S3G 800-CG02 -04
S3G 800-CH12 -14
S3G 800-CH03 -04
32.5
32.5
35.5
35.5
"A" U
Cable gland
Depth of screw
20-25 mm
"A" U
"A" U
281
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
3~ 380-480 50/60 720 1.15 1.80 100 -25 to +60 M)
282
EC axial fans mains-powered
S series, 910
Nominal data
Type Motor
*3G 910 M3G150-FF
*3G 910 M3G150-FF
subject to alterations
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
100
0
,
1
0
,
2
0
,
3
0
,
4
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 720 1.15 3.60 100 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
720
720
720
720
650
650
650
650
580
580
580
580
0.77
0.99
1.08
1.15
0.56
0.72
0.78
0.84
0.40
0.51
0.55
0.60
72
71
71
72
70
68
68
70
67
66
66
68

75
70
64

75
70
64

75
70
64
I
[A]
2.40
3.00
3.40
3.60
1.80
2.20
2.40
2.60
1.20
1.60
1.80
1.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
283
5000 10000 15000 20000 25000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
100
0
,
1
0
,
2
0
,
3
0
,
4
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 288 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
720
720
720
720
650
650
650
650
580
580
580
580
0.77
0.99
1.08
1.15
0.56
0.72
0.78
0.84
0.40
0.51
0.55
0.60
72
71
71
72
70
68
68
70
67
66
66
68

75
70
64

75
70
64

75
70
64
I
[A]
1.20
1.50
1.70
1.80
0.90
1.10
1.20
1.30
0.60
0.80
0.90
0.90
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
A3G 910-AG10 -13
A3G 910-AG10 -14
W3G910-CG10 -13
W3G910-CG10 -14
S3G 910-BG10 -13

S3G 910-AG10 -13

S3G 910-CG10 -14


"A"
"V"
A3G 910-AG02 -03
A3G 910-AG02 -04
W3G910-CG02 -03
W3G910-CG02 -04
S3G 910-BG02 -03

S3G 910-AG02 -03

S3G 910-CG02 -04


"A"
B
3~ 380-480 50/60 870 1.90 2.90 140 -25 to +60 M)
284
EC axial fans mains-powered
S series, 910
Nominal data
Type Motor
*3G 910 M3G150-IF
*3G 910 M3G150-IF
subject to alterations
5000 10000 15000 20000 25000 30000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
140
0
,
4
0
,
5
2
3
6
1 5
4
7
8
9
10
11
12
0
,
2
0
,
3
0
,
1
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 870 1.90 5.80 140 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
870
870
870
870
800
800
800
800
730
730
730
730
1.30
1.62
1.76
1.90
1.01
1.26
1.35
1.46
0.77
0.76
1.03
1.11
76
75
75
77
74
73
73
75
72
71
71
73

74
71
66

74
71
66

74
71
66
I
[A]
4.00
5.00
5.40
5.80
3.20
3.80
4.20
4.40
2.40
3.00
3.20
3.40
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
0
B
l
a
d
e

a
n
g
l
e
A
A3G 910-AH09 -13
A3G 910-AH09 -14
W3G910-CH09 -13
W3G910-CH09 -14
S3G 910-BH09 -13

S3G 910-AH09 -13

S3G 910-CH09 -14


A3G 910-AH04 -03
A3G 910-AH04 -04
W3G910-CH04 -03
W3G910-CH04 -04
S3G 910-BH04 -03

S3G 910-AH04 -03

S3G 910-CH04 -04


285
5000 10000 15000 20000 25000 30000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
140
0
,
4
0
,
5
2
3
6
1 5
4
7
8
9
10
11
12
0
,
2
0
,
3
0
,
1
[
P
a
]
[
i
n

H
2
O
]
Curves
Drawings
p. 288 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
870
870
870
870
800
800
800
800
730
730
730
730
1.30
1.62
1.76
1.90
1.01
1.26
1.35
1.46
0.77
0.76
1.03
1.11
76
75
75
77
74
73
73
75
72
71
71
73

74
71
66

74
71
66

74
71
66
I
[A]
2.00
2.50
2.70
2.90
1.60
1.90
2.10
2.20
1.20
1.50
1.60
1.70
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V"
"A"
"V"
"A"
B
286
EC axial fans mains-powered
S series, 910
Nominal data
Type Motor
*3G 910 M3G150-NA
subject to alterations
5000 10000 15000 20000 25000 30000
0 4000 8000
[m
3
/h]
[CFM] 16000 12000
20
40
60
80
120
100
160
180
200
220
140
0
,
2
0
,
4
0
,
6
0
,
8
2
3
6
1 5
4
7
8
9
10
11
12
[
P
a
]
[
i
n

H
2
O
]
Curves
(1) Nominal data in operating point with maximum load and 400 VAC
VAC Hz rpm kW A Pa C
3~ 380-480 50/60 980 2.80 4.30 220 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lw
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
980
980
980
980
900
900
900
900
820
820
820
820
1.82
2.24
2.55
2.80
1.41
1.76
1.97
2.15
1.07
1.31
1.49
1.63
80
80
83
86
78
78
82
84
76
76
80
82

73
65
56

73
65
56

73
65
56
I
[A]
2.80
3.40
3.90
4.30
2.20
2.60
3.00
3.30
1.60
2.00
2.30
2.50
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 5
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
0
B
l
a
d
e

a
n
g
l
e
A
287
Drawings
p. 288 ff.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V" A3G 910-AI02 -03
A3G 910-AI02 -04
W3G910-CI02 -03
W3G910-CI02 -04
S3G 910-BI02 -03

S3G 910-AI02 -03

S3G 910-CI02 -04 "A"


288
EC axial fans mains-powered
S series, 910, drawings for direction of air flow "V"
Without attachments
Type
g
Mass
[kg]
A3G 910-AG10 -13
A3G 910-AG02 -03
A3G 910-AH09 -13
A3G 910-AH04 -03
A3G 910-AI02 -03
249.5
249.5
249.5
249.5
284.5
25.5
25.5
28.5
28.5
33.0
With full square nozzle
Type Mass
[kg]
W3G910-CG10 -13
W3G910-CG02 -03
W3G910-CH09 -13
W3G910-CH04 -03
W3G910-CI02 -03
51.0
51.0
54.0
54.0
58.5
With guard grille for full nozzle
Type
t
Mass
[kg]
S3G 910-BG10 -13
S3G 910-BG02 -03
S3G 910-BH09 -13
S3G 910-BH04 -03
S3G 910-BI02 -03
134.5
134.5
134.5
134.5
169.5
34.0
34.0
37.0
37.0
41.5
"V"
Cable gland
Depth of screw
20-25 mm
"V"
"V"
20
1
0116
1
5
2
9
76
View X
289
With guard grille for short nozzle
Type
v
Mass
[kg]
S3G 910-AG10 -13
S3G 910-AG02 -03
S3G 910-AH09 -13
S3G 910-AH04 -03
S3G 910-AI02 -03
19.5
19.5
19.5
19.5
54.5
36.0
36.0
39.0
39.0
43.5
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
290
EC axial fans mains-powered
S series, 910, drawings for direction of air flow "A"
Without attachments
Type
g
Mass
[kg]
A3G 910-AG10 -14
A3G 910-AG02 -04
A3G 910-AH09 -14
A3G 910-AH04 -04
A3G 910-AI02 -04
249.5
249.5
249.5
249.5
284.5
25.5
25.5
28.5
28.5
33.0
With full square nozzle
Type Mass
[kg]
W3G910-CG10 -14
W3G910-CG02 -04
W3G910-CH09 -14
W3G910-CH04 -04
W3G910-CI02 -04
52.0
52.0
55.0
55.0
59.5
With guard grille for full nozzle
Type
t
Mass
[kg]
S3G 910-CG10 -14
S3G 910-CG02 -04
S3G 910-CH09 -14
S3G 910-CH04 -04
S3G 910-CI02 -04
160.5
160.5
160.5
160.5
195.5
35.0
35.0
38.0
38.0
42.5
"A" U
Cable gland
Depth of screw
20-25 mm
"A" U
"A" U
291
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
3~ 380-480 50/60 545 0.90 1.90 90 -25 to +60 M)
292
EC axial fans mains-powered
S series, 990
Nominal data
Type Motor
*3G 990 M3G150-FF
*3G 990 M3G150-FF
subject to alterations
5000 15000 25000
0 3000 6000 9000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
[CFM] 12000 15000 18000
9
10
11
12
6
7
2
8
3
4
5 1
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 545 0.90 3.80 90 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
545
545
545
545
450
450
450
450
380
380
380
380
0.63
0.74
0.81
0.88
0.36
0.42
0.46
0.50
0.22
0.26
0.28
0.31
70
71
71
70
65
66
66
65
61
61
61
61

72
70
57

72
70
57

72
70
57
I
[A]
2.40
2.60
2.80
3.00
1.40
1.60
1.80
1.80
0.80
1.00
1.20
1.20
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 7
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
293
5000 15000 25000
0 3000 6000 9000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
[CFM] 12000 15000 18000
9
10
11
12
6
7
2
8
3
4
5 1
Curves
Drawings
p. 298 f.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
545
545
545
545
450
450
450
450
380
380
380
380
0.63
0.74
0.81
0.88
0.36
0.42
0.46
0.50
0.22
0.26
0.28
0.31
70
71
71
70
65
66
66
65
61
61
61
61

72
70
57

72
70
57

72
70
57
I
[A]
1.20
1.30
1.40
1.50
0.70
0.80
0.90
0.90
0.40
0.50
0.60
0.60
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, CCC, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V" A3G 990-AC03 -03
A3G 990-AC03 -04
W3G990-CC03 -03
W3G990-CC03 -04
S3G 990-BC03 -03

S3G 990-CC03 -04 "A"


"V" A3G 990-AC04 -13
A3G 990-AC04 -14
W3G990-CC04 -13
W3G990-CC04 -14
S3G 990-BC04 -13

S3G 990-CC04 -14 "A"


B
3~ 380-480 50/60 650 1.50 2.60 120 -25 to +60 M)
294
EC axial fans mains-powered
S series, 990
Nominal data
Type Motor
*3G 990 M3G150-IF
*3G 990 M3G150-IF
subject to alterations
5000 15000 25000
0 3000 6000 9000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
[CFM] 12000 15000 18000
9
10
11
12
6
7
2
8
3
4
5 1
Curves
(1) Nominal data in operating point with maximum load and 200 or 400 VAC
VAC Hz rpm kW A Pa C
3~ 200-240 50/60 650 1.50 4.80 120 -25 to +60 A
B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
650
650
650
650
540
540
540
540
450
450
450
450
1.02
1.21
1.32
1.44
0.60
0.71
0.78
0.84
0.36
0.42
0.46
0.50
75
76
76
75
70
71
71
70
65
66
66
65

72
70
57

72
70
57

72
70
57
I
[A]
3.60
4.00
4.40
4.60
2.20
2.60
2.80
3.00
1.40
1.60
1.80
1.80
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 7
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
295
5000 15000 25000
0 3000 6000 9000
[
P
a
]
20
40
60
80
100
120
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
[m
3
/h]
[CFM] 12000 15000 18000
9
10
11
12
6
7
2
8
3
4
5 1
Curves
Drawings
p. 298 f.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
n
[rpm]
P
1
[kW]
Lp
A
[dB(A)]

tL
[%]
B
B
1
2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B 10
B 11
B 12
650
650
650
650
540
540
540
540
450
450
450
450
1.02
1.21
1.32
1.44
0.60
0.71
0.78
0.84
0.36
0.42
0.46
0.50
75
76
76
75
70
71
71
70
65
66
66
65

72
70
57

72
70
57

72
70
57
I
[A]
1.80
2.00
2.20
2.30
1.10
1.30
1.40
1.50
0.70
0.80
0.90
0.90
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, CSA, GOST; also VDE B
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V" A3G 990-AD05 -03
A3G 990-AD05 -04
W3G990-CD05 -03
W3G990-CD05 -04
S3G 990-BD05 -03

S3G 990-CD05 -04 "A"


"V" A3G 990-AD11 -13
A3G 990-AD11 -14
W3G990-CD11 -13
W3G990-CD11 -14
S3G 990-BD11 -13

S3G 990-CD11 -14 "A"


B
296
EC axial fans mains-powered
S series, 990
Nominal data
Type Motor
*3G 990 M3G150-NA
subject to alterations
5000 15000 25000
0 3000 6000 9000
[
P
a
]
20
40
60
80
100
120
140
0
,
1
0
,
3
0
,
4
[
i
n

H
2 O
]
0
,
2
0
,
5
[m
3
/h]
12000 15000 [CFM] 18000
3
4
2
9
10
11
12
6
5 1
7
8
Curves
(1) Nominal data in operating point with maximum load and 400 VAC
VAC Hz rpm kW A Pa C
3~ 380-480 50/60 720 2.00 3.00 150 -25 to +60 A
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
n
[rpm]
P
1
[kW]
Lp
A
[dB(A)]

tL
[%]
A
A
1
2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 11
A 12
M
a
x
.
p
o
w
e
r

i
n
p
u
t
(
1
)
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
(
1
)
p. 428
M)
E
l
e
c
t
r
.
c
o
n
n
e
c
t
i
o
n
720
720
720
720
655
655
655
655
580
580
580
580
1.47
1.72
1.89
1.99
1.10
1.29
1.40
1.51
0.77
0.90
0.97
1.05
74
75
77
78
72
73
74
76
73
74
75
77

79
73
60

75
73
60

75
73
60
I
[A]
2.20
2.60
2.90
3.00
1.70
2.00
2.10
2.30
1.20
1.40
1.50
1.60
Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
Number of blades: 7
Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharges: Rotor-side
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
A
297
Drawings
p. 298 f.
Electr. connection
p. 428
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technical features: Slave output 0-10 V max. 3 mA Line undervoltage / phase failure detection
PFC (passive) Output 20 VDC (20 %) max. 50 mA Motor current limitation
Integrated PID controller Output 10 VDC (+10 %) max. 10 mA Over-temperature protected electronics / motor
Control input 0-10 VDC / PWM RS485 ebmBUS Locked rotor protection
Input for sensor 0-10 V or 4-20 mA Alarm relay Soft start
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 61800-5-1
Connection leads: Via terminal strip
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Without
attachments
With guard grille
for full nozzle
With full
square nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
D
i
r
e
c
t
i
o
n

o
f

a
i
r

f
l
o
w
"V"/ "A" U "V"/ "A" U "V" "V" "A" U
"V" A3G 990-AE03 -03
A3G 990-AE03 -04
W3G990-CE03 -03
W3G990-CE03 -04
S3G 990-BE03 -03

S3G 990-CE03 -04 "A"


298
EC axial fans mains-powered
S series, 990, drawings for direction of air flow "V"
Without attachments
Type
g
Mass
[kg]
A3G 990-AC04 -13
A3G 990-AC03 -03
A3G 990-AD11 -13
A3G 990-AD05 -03
A3G 990-AE03 -03
219.5
219.5
249.5
249.5
284.5
26.5
26.5
30.5
30.5
35.0
With full square nozzle
Type Mass
[kg]
W3G990-CC04 -13
W3G990-CC03 -03
W3G990-CD11 -13
W3G990-CD05 -03
W3G990-CE03 -03
55.0
55.0
59.0
59.0
63.5
With guard grille for full nozzle
Type
t
Mass
[kg]
S3G 990-BC04 -13
S3G 990-BC03 -03
S3G 990-BD11 -13
S3G 990-BD05 -03
S3G 990-BE03 -03
122.0
122.0
152.0
152.0
187.0
36.5
36.5
40.5
40.5
45.0
"V"
Cable gland Depth of screw
20-25 mm
"V"
"V"
1
52
9
20
116
1
0
76
View X
299
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC axial fans mains-powered
S series, 990, drawings for direction of air flow "A"
Without attachments
Type
g
Mass
[kg]
A3G 990-AC04 -14
A3G 990-AC03 -04
A3G 990-AD11 -14
A3G 990-AD05 -04
A3G 990-AE03 -04
219.5
219.5
249.5
249.5
284.5
26.5
26.5
30.5
30.5
35.0
With full square nozzle
Type Mass
[kg]
W3G990-CC04 -14
W3G990-CC03 -04
W3G990-CD11 -14
W3G990-CD05 -04
W3G990-CE03 -04
56.0
56.0
60.0
60.0
64.5
With guard grille for full nozzle
Type
t
Mass
[kg]
S3G 990-CC04 -14
S3G 990-CC03 -04
S3G 990-CD11 -14
S3G 990-CD05 -04
S3G 990-CE03 -04
169.5
169.5
199.5
199.5
234.5
37.5
37.5
41.5
41.5
46.0
"A" U
Cable gland
"A" U
"A" U
Depth of screw
20-25 mm
300
Table of options
= available ex stock
Foot measure
Mount
Electr. terminals
18 mm (height 48 mm)
26 mm (height 51 mm)
A side (3 x M4, 71.4 mm)
B side (3 x M4, 71.4 mm)
Thread ends, A side (4 x M4)
Jacketed cable (3 x 0.5 mm
2
)
Plug terminal (3 x 0.5 mm
2
)
UL jacketed cable (3 x AWG20)
Page 302 Page 304 Page 305 Page 306 Page 307
G G
G G G G
G
G G
G G G G G
450 mm 1500 mm 1500 mm
G
450 mm
S
t
a
n
d
a
r
d
M
u
l
t
i
-
f
u
n
c
t
i
o
n
F
r
i
g
o
P
l
u
g

t
e
r
m
i
n
a
l
U
L

a
n
d

C
S
A
301
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Square shaded-pole motors (Q-motors)
Air performance curves 308
UL and CSA design 307
Plug terminal design 306
Frigo design 305
Multi-function design 304
Standard design 302
302
Square shaded-pole motors
Standard design
Foot mounting: Track dimension 26 mm (height 51 mm)
Type of protection: IP 42
Electrical connection: Jacketed cable 3 x 0.5 mm
2
with brass lead tips
Product conforming to standard: CE
Approvals: VDE
Curves: Page 308
Nominal data Dimensions
Type
M4Q045-BD01 -01
M4Q045-CA01 -01
A
B
M4Q045-CA03 -51 C
M4Q045-CF01 -01 D
M4Q045-DA01 -01
(1)
E
M4Q045-DA05 -01
(1)
F
M4Q045-EA01 -01
(1)
G
M4Q045-EF01 -01
(1)
H
subject to alterations
VAC Hz rpm W W A C kg B E K
76 42 15
82 42 15
82 42 15
87 42 15
93 54 15
93 54 15
103 59 16
125 79 33
1~ 230 50 1300 5 29 0.19 -30 to +40
1~ 230 60 1550 5 26 0.17 -30 to +40
A
B
0.9
1~ 230 50 1300 7 31 0.20 -30 to +40
1~ 230 60 1550 8 30 0.20 -30 to +40
C
D
1.1
1~ 230 50 1300 10 36 0.25 -30 to +40
1~ 230 60 1550 9 34 0.22 -30 to +40
E
F
1.2
1~ 230 50 1300 16 60 0.42 -30 to +40
1~ 230 60 1550 16 58 0.36 -30 to +40
G
H
1.3
1~ 230 50 1300 18 70 0.48 -30 to +40
1~ 230 60 1550 18 62 0.42 -30 to +40
I
J
1.6
1~ 230 50 1300 23 86 0.62 -30 to +40
1~ 230 60 1550 25 80 0.55 -30 to +40
K
L
1.6
1~ 230 50 1300 25 90 0.62 -30 to +40
1~ 230 60 1550 26 80 0.55 -30 to +40
M
N
2.0
1~ 230 50 1300 34 110 0.75 -30 to +40
1~ 230 60 1550 34 100 0.65 -30 to +40
O
P
2.2
C
u
r
v
e
C
o
m
b
i
n
a
t
i
o
n
:
M
o
t
o
r

a
x
i
a
l

i
m
p
e
l
l
e
r
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
P
o
w
e
r

o
u
t
p
u
t
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
(1) Foot mounting possible on A or B side
K
5
1
H
4
5
0
26
1,5
67
83
B
2
G
E
2
M4
C

3
,
6

2
5
,
4
F
2
58
7
1
,
4
41

D
Foot measure
Guard grille
p. 378
Axial impeller
p. 377
Basket guard grille
p. 378
Wall ring
p. 379
Mounting bracket
p. 380
B side A side
"V" "A" U

D
i
r
e
c
t
i
o
n

o
f

r
o
t
a
t
i
o
n
303
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Material: Housing made of die-cast aluminium
Stator pack: Coated in black
Direction of air flow: "V" or "A" (depending on axial impeller used)
Direction of rotation: Counter-clockwise, seen on shaft end
Insulation class: "B"
Mounting position: Any, preferrably horizontal
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearing: Self-adjusting calotte sleeve bearing (mean service life of
30,000 hours in horizontal installation position)
Motor protection: Impedance protection (combination A-C) or thermal
overload protector internally switched (combination D-H)
Protection class: I
Valid for all designs:
Mounting: Guard grille and wall ring are mounted onto the protruding
thread ends of the A side. The Q-motor can also be screwed on via the
mounting flanges (integrated in the bearing shields).
Axial impeller mounting: Mounted to the motor shaft using a plastic
adapter with pulling peg and an M4 screw (combination A-D) or M5
(combination E-H) screw.
Power specifications: At 60 Hz, the blade angle of the axial impellers
must be reduced by 6 each.
Axial impellers
D H
154 90
F G C m
3
/h
(2)
Blade angle 22 130 Blade angle 28 130 Blade angle 34 130
61 56 27.5 60
58 57 31.0 120
58 58 32.0 190
65 58 32.0 190
64 62 35.0 500
64 62 35.0 500
64 62 37.0 580
70 62 37.0 580
76 74 37.0 580
75 79 43.0 1000
75 79 43.0 1000
86 84 43.0 1000
108 104 43.0 1000
F G C m
3
/h
(2)
56 59 32.0 100
55 59 36.0 180
55 60 37.5 300
62 60 37.5 300

60 65 43.0 630

65 66 45.0 840
72 78 45.0 840

67 81 53.5 1400
77 86 53.5 1400
104 106 53.5 1400
F G C m
3
/h
(2)
54 62 37.0 140
53 63 42.0 230

59 64 45.0 400

52 68 50.0 820


67 80 52.0 1070



95 112 61.0 1700
172 103
200 123
200 123
230 123
230 123
254 135
254 135
300 160
300 160
300 160
254 135
300 160
(2) established at counterpressure of 20 Pa
304
Square shaded-pole motors
Multi-function design
Foot mounting: Track dimension 26 mm (height 51 mm) or 18 mm (height 48 mm)
possible
Bearing shields: A and B-sides, tapped holes 3x M4, diameter of pitch circle 71.4 mm;
mounting of guard grille and wall ring on A-side bearing shield;
opposite M4 are securely installed in the feet
(knurled hex nuts are not included in delivery scope)
Type of protection: IP 42
Electrical connection: Jacketed cable 3 x 0.5 mm
2
with brass lead tips
Product conforming to standard: CE
Approvals: VDE
Curves: Page 308
Nominal data Dimensions
Type p.302
M4Q045-BD01 -75
M4Q045-CA01 -75
M4Q045-CA03 -75
M4Q045-CF01 -75
M4Q045-DA01 -75
M4Q045-DA05 -75
M4Q045-EA01 -75
M4Q045-EF01 -75
A
B
C
D
E
F
G
H
subject to alterations
VAC Hz rpm W W A C kg A B E F K
43 76 43.5 12 15.0
49 82 43.5 10 15.0
49 82 43.5 10 15.0
54 87 43.5 10 15.0
59 93 43.5 10 15.0
59 93 43.5 10 15.0
69 103 44.0 10 15.5
92 125 61.0 10 33.0
1~ 230 50 1300 5 29 0.19 -30 to +40
1~ 230 60 1550 5 26 0.17 -30 to +40
A
B
0.9
1~ 230 50 1300 7 31 0.20 -30 to +40
1~ 230 60 1550 8 30 0.20 -30 to +40
C
D
1.1
1~ 230 50 1300 10 36 0.25 -30 to +40
1~ 230 60 1550 9 34 0.22 -30 to +40
E
F
1.2
1~ 230 50 1300 16 60 0.42 -30 to +40
1~ 230 60 1550 16 58 0.36 -30 to +40
G
H
1.3
1~ 230 50 1300 18 70 0.48 -30 to +40
1~ 230 60 1550 18 62 0.42 -30 to +40
I
J
1.6
1~ 230 50 1300 23 86 0.62 -30 to +40
1~ 230 60 1550 25 80 0.55 -30 to +40
K
L
1.6
1~ 230 50 1300 25 90 0.62 -30 to +40
1~ 230 60 1550 26 80 0.55 -30 to +40
M
N
2.0
1~ 230 50 1300 34 110 0.75 -30 to +40
1~ 230 60 1550 34 100 0.65 -30 to +40
O
P
2.2
C
u
r
v
e
C
o
m
b
i
n
a
t
i
o
n
:
M
o
t
o
r

a
x
i
a
l

i
m
p
e
l
l
e
r
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
P
o
w
e
r

o
u
t
p
u
t
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s

3
,
6
67
71,4
3x120
M
4
7
1
,
4
M
4
3x120
M
4
1
1
,
5 M4
M4
26
4
8
5
1

2
5
,
4
M
4

(
4
x
)
8
5
1
5
0
0
83
18
M4
M4
1
3
M
4
A
B
E 2
F
K
Foot measure
Guard grille
p. 378
Axial impeller
p. 377
Basket guard grille
p. 378
Wall ring
p. 379
Mounting bracket
p. 380
B side A side
Foot measure
305
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Square shaded-pole motors
Frigo design (specially for spare parts requirements)
Foot mounting: Track dimension 18 mm (height 48 mm)
Bearing shields: B-side, tapped holes 3 x M4, diameter of pitch circle 71.4 mm;
mounting of guard grille and wall ring on A-side bearing shield;
M4 knurled hex nuts (2x) are enclosed in loose form
Type of protection: IP 42
Electrical connection: Jacketed cable 3 x 0.5 mm
2
with brass lead tips
Product conforming to standard: CE
Approvals: VDE
Curves: Page 308
Nominal data Dimensions
Type p.302
M4Q045-BD01 -A4
M4Q045-CA01 -N4
M4Q045-CA03 -A4
M4Q045-CF01 -A4
M4Q045-DA01 -A4
M4Q045-DA05 -A4
M4Q045-EA01 -A4
M4Q045-EF01 -A4
A
B
C
D
E
F
G
H
subject to alterations
VAC Hz rpm W W A C kg A B F K
48.5 76 12 15
48.5 82 10 15
48.5 82 10 15
48.5 87 10 15
48.5 93 10 15
48.5 93 10 15
49.0 103 10 16
66.0 125 10 33
1~ 230 50 1300 5 29 0.19 -30 to +40
1~ 230 60 1550 5 26 0.17 -30 to +40
A
B
0.9
1~ 230 50 1300 7 31 0.20 -30 to +40
1~ 230 60 1550 8 30 0.20 -30 to +40
C
D
1.1
1~ 230 50 1300 10 36 0.25 -30 to +40
1~ 230 60 1550 9 34 0.22 -30 to +40
E
F
1.2
1~ 230 50 1300 16 60 0.42 -30 to +40
1~ 230 60 1550 16 58 0.36 -30 to +40
G
H
1.3
1~ 230 50 1300 18 70 0.48 -30 to +40
1~ 230 60 1550 18 62 0.42 -30 to +40
I
J
1.6
1~ 230 50 1300 23 86 0.62 -30 to +40
1~ 230 60 1550 25 80 0.55 -30 to +40
K
L
1.6
1~ 230 50 1300 25 90 0.62 -30 to +40
1~ 230 60 1550 26 80 0.55 -30 to +40
M
N
2.0
1~ 230 50 1300 34 110 0.75 -30 to +40
1~ 230 60 1550 34 100 0.65 -30 to +40
O
P
2.2
C
u
r
v
e
C
o
m
b
i
n
a
t
i
o
n
:
M
o
t
o
r

a
x
i
a
l

i
m
p
e
l
l
e
r
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
P
o
w
e
r

o
u
t
p
u
t
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
M
4
M
4
(
4
x
)

2
5
,
4

3
,
6
4
8
1
3
A
B
F
K
M
4
71,4
3
x
1
2
0

M4
18
M4
67
83
85
1500
Foot measure
Guard grille
p. 378
Axial impeller
p. 377
Basket guard grille
p. 378
Wall ring
p. 379
Mounting bracket
p. 380
B side A side
306
Square shaded-pole motors
Plug terminal design
Foot mounting: Track dimension 26 mm (height 51 mm)
Type of protection: IP 42
Electrical connection: Rast 5.6 mm terminal connector, 2.8 x 0.5 mm blade terminal;
connection lines available in 420 mm to 4970 mm lengths
Product conforming to standard: CE
Approvals: VDE (put into operation with ebm-papst connection line only!)
Curves: Page 308
Nominal data Dimensions
Type p.302
M4Q045-BD01 -08
M4Q045-CA01 -08
M4Q045-CA03 -08
M4Q045-CF01 -08
M4Q045-DA01 -52
(1)
M4Q045-DA05 -52
(1)
M4Q045-EA01 -52
(1)
M4Q045-EF01 -52
(1)
A
B
C
D
E
F
G
H
subject to alterations
VAC Hz rpm W W A C kg B E F K
76 43.5 12 15
82 43.5 10 15
82 43.5 10 15
87 43.5 10 15
93 43.5 10 15
93 43.5 10 15
103 44.0 10 16
125 61.0 10 33
1~ 230 50 1300 5 29 0.19 -30 to +40
1~ 230 60 1550 5 26 0.17 -30 to +40
A
B
0.9
1~ 230 50 1300 7 31 0.20 -30 to +40
1~ 230 60 1550 8 30 0.20 -30 to +40
C
D
1.1
1~ 230 50 1300 10 36 0.25 -30 to +40
1~ 230 60 1550 9 34 0.22 -30 to +40
E
F
1.2
1~ 230 50 1300 16 60 0.42 -30 to +40
1~ 230 60 1550 16 58 0.36 -30 to +40
G
H
1.3
1~ 230 50 1300 18 70 0.48 -30 to +40
1~ 230 60 1550 18 62 0.42 -30 to +40
I
J
1.6
1~ 230 50 1300 23 86 0.62 -30 to +40
1~ 230 60 1550 25 80 0.55 -30 to +40
K
L
1.6
1~ 230 50 1300 25 90 0.62 -30 to +40
1~ 230 60 1550 26 80 0.55 -30 to +40
M
N
2.0
1~ 230 50 1300 34 110 0.75 -30 to +40
1~ 230 60 1550 34 100 0.65 -30 to +40
O
P
2.2
C
u
r
v
e
C
o
m
b
i
n
a
t
i
o
n
:
M
o
t
o
r

a
x
i
a
l

i
m
p
e
l
l
e
r
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
P
o
w
e
r

o
u
t
p
u
t
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
(1) Foot mounting possible on A or B side
1
8
2
0
14,5
9
83
67
M4
26
K
E
F
9
5
B
5
1
1
1
,
5

2
5
,
4

3
,
6
M
4
(
4
x
)
Foot measure
Guard grille
p. 378
Axial impeller
p. 377
Connection lead
p. 376
Basket guard grille
p. 378
Wall ring
p. 379
Mounting bracket
p. 380
B side
Blade terminal
2.8 x 0.5 mm
Rast 5.6 mm
A side
According to VDE, motor
must be put into operation
with ebm-papst connection
line only!
PE
307
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Square shaded-pole motors
UL and CSA design
Description: Designs with UL/CSA approvals; connection lines, temperature monitor and
dynamo wire are UL/CSA-approved components
Foot mounting: Track dimension 26 mm (height 51 mm)
Type of protection: IP 42
Electrical connection: Jacketed cable 3 x AWG20 with brass lead tips
Product conforming to standard: UL547, UL1004, CSA C22.2 No. 100,
CSA C22.2 No. 77, CE
Approvals: UL, CSA
Curves: Page 308
Drawing: See standard design on page 302
Nominal data Dimensions
Type p.302
M4Q045-BD01 -04
(2)
M4Q045-CA01 -04
(2)
M4Q045-CA25 -04
(2)
M4Q045-CF01 -04
(2)
M4Q045-DA01 -04
(1)(3)
M4Q045-DA05 -04
(1)(3)
M4Q045-EA01 -04
(1)(3)
M4Q045-EF01 -04
(1)(3)
A
B
C
D
E
F
G
H
subject to alterations
VAC Hz rpm W W A C kg B E K
76 42 15
82 42 15
82 42 15
87 42 15
93 54 15
93 54 15
103 59 16
125 79 33
1~ 230 50 1300 5 29 0.19 -30 to +40
1~ 230 60 1550 5 26 0.17 -30 to +40
A
B
0.9
1~ 230 50 1300 7 31 0.20 -30 to +40
1~ 230 60 1550 8 30 0.20 -30 to +40
C
D
1.1
1~ 230 50 1300 10 36 0.25 -30 to +40
1~ 230 60 1550 9 34 0.22 -30 to +40
E
F
1.2
1~ 230 50 1300 16 60 0.42 -30 to +40
1~ 230 60 1550 16 58 0.36 -30 to +40
G
H
1.3
1~ 230 50 1300 18 70 0.48 -30 to +40
1~ 230 60 1550 18 62 0.42 -30 to +40
I
J
1.6
1~ 230 50 1300 23 86 0.62 -30 to +40
1~ 230 60 1550 25 80 0.55 -30 to +40
K
L
1.6
1~ 230 50 1300 25 90 0.62 -30 to +40
1~ 230 60 1550 26 80 0.55 -30 to +40
M
N
2.0
1~ 230 50 1300 34 110 0.75 -30 to +40
1~ 230 60 1550 34 100 0.65 -30 to +40
O
P
2.2
M4Q045-BD03 -04
(2)
M4Q045-CA17 -04
(2)
M4Q045-CA27 -04
(2)
M4Q045-CF07 -04
(2)
M4Q045-DA11 -04
(1)(3)
M4Q045-DA13 -04
(1)(3)
M4Q045-EA03 -04
(1)(3)
M4Q045-EF03 -04
(1)(3)
A
B
C
D
E
F
G
H
76 42 15
82 42 15
82 42 15
87 42 15
93 54 15
93 54 15
103 59 16
125 79 33
1~ 115 50 1300 5 29 0.38 -30 to +40
1~ 115 60 1550 5 26 0.35 -30 to +40
A
B
0.9
1~ 115 50 1300 7 31 0.40 -30 to +40
1~ 115 60 1550 8 30 0.40 -30 to +40
C
D
1.1
1~ 115 50 1300 10 36 0.50 -30 to +40
1~ 115 60 1550 9 34 0.45 -30 to +40
E
F
1.2
1~ 115 50 1300 16 60 0.80 -30 to +40
1~ 115 60 1550 16 58 0.74 -30 to +40
G
H
1.3
1~ 115 50 1300 18 70 0.98 -30 to +40
1~ 115 60 1550 18 62 0.87 -30 to +40
I
J
1.6
1~ 115 50 1300 23 86 1.25 -30 to +40
1~ 115 60 1550 25 80 1.10 -30 to +40
K
L
1.6
1~ 115 50 1300 25 90 1.25 -30 to +40
1~ 115 60 1550 26 80 1.10 -30 to +40
M
N
2.0
1~ 115 50 1300 34 110 1.50 -30 to +40
1~ 115 60 1550 34 100 1.35 -30 to +40
O
P
2.2
C
u
r
v
e
C
o
m
b
i
n
a
t
i
o
n
:
M
o
t
o
r

a
x
i
a
l

i
m
p
e
l
l
e
r
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
S
p
e
e
d
/
r
p
m
P
o
w
e
r

o
u
t
p
u
t
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
(1) A and B-side foot mounting possible (2) File No. E 171165 (3) File No. E 76226
Guard grille
p. 378
Axial impeller
p. 377
Basket guard grille
p. 378
Wall ring
p. 379
Mounting bracket
p. 380
308
Square shaded-pole motors
Air performance curves (measured in wall ring)
50 100 150 200 250
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
80
90
22 28 34
50 100 150 200 250
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
80
90
22 28 34
M4Q045-BD01-**, 154, 50 Hz M4Q045-BD01-**, 154, 60 Hz
50 100 150 200 250 300
[
P
a
]
10
[m
3
/h]
20
30
40
50
22 28 34
50 100 150 200 250 300 350
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
22 28 34
M4Q045-BD01-**, 172, 50 Hz M4Q045-BD01-**, 172, 60 Hz
A B
A B
309
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
50 100 150 200 250 300 350
[
P
a
]
10
[m
3
/h]
20
30
40
50
22 28
50 100 150 200 250 300 350 400
[
P
a
]
10
[m
3
/h]
20
30
40
50
22 28
M4Q045-BD01-**, 200, 50 Hz M4Q045-BD01-**, 200, 60 Hz
100 200 300 400
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
22 28 34
100 200 300 400
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
22 28 34
M4Q045-CA01-**, 200, 50 Hz M4Q045-CA01-**, 200, 60 Hz
A B
C D
310
100 200 300 400
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
22
100 200 300 500 400
[
P
a
]
10
[m
3
/h]
20
30
40
22
M4Q045-CA01-**, 230, 50 Hz M4Q045-CA01-**, 230, 60 Hz
100 200 300 400 500 600 700
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
70
80
22 28 34
100 200 300 400 500 600 700
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
22 28 34
M4Q045-CA03-**, 230, 50 Hz M4Q045-CA03-**, 230, 60 Hz
C D
E F
Square shaded-pole motors
Air performance curves (measured in wall ring)
311
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
100 200 300 400 500 600
[
P
a
]
10
[m
3
/h]
20
30
40
50
60
22
100 200 300 400 500 600 700
[
P
a
]
5
[m
3
/h]
10
15
20
25
30
35
22
M4Q045-CA03-**, 254, 50 Hz M4Q045-CA03-**, 254, 60 Hz
200 400 600 800
[
P
a
]
[m
3
/h]
20
40
60
80
100
22 28
200 400 600 800
[
P
a
]
[m
3
/h]
20
40
60
80
22 28
M4Q045-CF01-**, 254, 50 Hz M4Q045-CF01-**, 254, 60 Hz
E F
G H
312
Square shaded-pole motors
Air performance curves (measured in wall ring)
200 400 600 800
[
P
a
]
[m
3
/h]
20
40
60
80
100
22 28 34
200 400 600 800 1000
[
P
a
]
[m
3
/h]
20
40
60
80
100
22 28 34
M4Q045-DA01-**, 254, 50 Hz M4Q045-DA01-**, 254, 60 Hz
I J
200 400 800 600 1000
[
P
a
]
[m
3
/h]
20
40
60
80
100
22
1200
I
K
200 800 400 1000 600 1200
[
P
a
]
10
[m
3
/h]
20
30
40
22
L
J
M4Q045-DA01-** / -DA05-**, 300, 50 Hz K I M4Q045-DA01-** / -DA05-**, 300, 60 Hz L J
313
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
200 400 800 600 1000 1200
[
P
a
]
[m
3
/h]
20
40
60
100
80
22
200 400 600 800 1000 1200 1400
[
P
a
]
10
[m
3
/h]
20
30
40
50
22
M4Q045-EA01-**, 300, 50 Hz M4Q045-EA01-**, 300, 60 Hz
400 1200 1600 800
[
P
a
]
[m
3
/h]
20
40
60
100
80
22 28 34
400 800 1200 1600
[
P
a
]
[m
3
/h]
20
40
60
80
22 28 34
M4Q045-EF01-**, 300, 50 Hz M4Q045-EF01-**, 300, 60 Hz
M N
O P
314
315
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Energy-saving motors (ESM)
Energy-saving axial fans 326
Air performance curves 320
Energy-saving motors (ESM) 316
316
Energy-saving motors (ESM)
Material: Housing made of die-cast aluminium
Rotor: Coated in black
Direction of air flow: "V" or "A" (depending on axial impeller used)
Direction of rotation: Counter-clockwise, seen on shaft end
Type of protection: IP 44
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Type
subject to alterations
VAC Hz rpm rpm W W C kg
50/60 2200 1500 22.0 15.0 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD95 -12
M1G055-BD91 -12
A
A
50/60 1750 1300 22.0 12.5 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD95 -16
M1G055-BD91 -16
B
B
50/60 1550 1100 21.0 10.4 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD95 -21
M1G055-BD91 -21
C
C
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
U
p
p
e
r

s
p
e
e
d
(
1
)
L
o
w
e
r

s
p
e
e
d
(
1
)
P
o
w
e
r

i
n
p
u
t
P
o
w
e
r

o
u
t
p
u
t
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
(1) preprogrammed speeds
Nominal data
B side A side
"V" "A" U

D
i
r
e
c
t
i
o
n

o
f

r
o
t
a
t
i
o
n
Fastening thread M4
Including line cord with
plug (450 mm long)
Axial impeller
p. 377
Connection lead
p. 374
Programming
device p. 375
(Basket) guard grille
p. 378
Wall ring
p. 379
Mounting angle
p. 381
317
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
D
154
m
3
/h
(2)
W
(3)
F C
Blade angle 22 130 Blade angle 28 130 Blade angle 34 130
250 4.0
170 1.3
74.0 27.5
380 7.0
260 2.2
72.0 31.0
560 13.4
380 4.3
71.5 32.0
200 2.0
150 1.3
74.0 27.5
300 3.5
225 2.2
72.0 31.0
450 6.7
335 4.2
71.5 32.0
180 1.4
130 0.5
74.0 27.5
270 2.5
190 0.9
72.0 31.0
400 4.7
285 1.7
71.5 32.0
710
(4)
15.4
505 6.0
70.0 35.0
440 10.0
300 3.2
69.5 36.0
640
(4)
19.5
435 6.2
69.0 37.5
250 2.7
215 1.7
71.5 32.0
350 5.0
300 3.2
69.5 36.0
510 9.9
440 6.2
69.0 37.5
220 1.9
155 0.7
71.5 32.0
310 3.5
220 1.3
69.5 36.0
450 6.9
320 2.5
69.0 37.5
m
3
/h
(2)
W
(3)
F C
310 5.3
210 1.7
71.5 32.0
500 13.6
340 4.3
66.5 42.0
280 3.4
240 2.1
69.0 37.0
400 6.8
345 4.3
66.5 42.0
620
(4)
16.8
530 10.6
65.0 45.0
240 2.3
170 0.8
69.0 37.0
350 4.8
250 1.7
66.5 42.0
550
(4)
12.7
390 4.5
65.0 45.0
m
3
/h
(2)
W
(3)
F C
350 6.7
240 2.1
69.0 37.0
rpm
2200
1500
2200
1500
2200
1500
1750
1300
1750
1300
1750
1300
1550
1100
1550
1100
1550
1100
1550
1100
172
200
154
172
200
154
172
200
230
(2) Running at free air flow (3) Power requirement of impeller (4) Permitted with corresponding cooling of the motor (shaft power > output power)
Motor protection: Via electronics
Electrical connection: Line cord with plug
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL
Curves: Page 320
Speed settings: The pre-programmed upper speed is reached
with the speed relay open; lower speed is reached when the speed
relay is closed.
Speeds from 10% to 100% of the maximum speed can be preset
using the programming unit (see page 375). However, we recommend
not allowing it to fall below 1000 rpm ( ).
Mounting: Guard grille and wall ring are mounted onto the protruding
thread ends of the A side.
Axial impeller mounting: Mounted to the motor shaft using a plastic
adapter with pulling peg and an M4 screw.
C B A
Axial impellers
Power system: 115 or 230 VAC,
50/60 Hz
L1
N
black
blue
brown
1
2
5
Speed selection
115 or 230 VAC
L or N
Energy-
saving
motor
(ESM)
Electr.
connection:
318
Energy-saving motors (ESM)
Material: Housing made of die-cast aluminium
Rotor: Coated in black
Direction of air flow: "V" or "A" (depending on axial impeller used)
Direction of rotation: Counter-clockwise, seen on shaft end
Type of protection: IP 44
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Type
subject to alterations
VAC Hz rpm rpm W W C kg
50/60 1400 1000 9.0 5.9 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD91 -45
M1G055-BD87 -25
D
D
50/60 1400 1000 27.0 12.0 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD95 -26
M1G055-BD91 -26
E
E
50/60 1200 800 15.4 6.3 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD95 -30
M1G055-BD91 -30
G
G
50/60 1200 800 12.0 7.5 -30 to +50 0.9
1~ 115
1~ 230
M1G055-BD91 -17
M1G055-BD87 -17
F
F
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
U
p
p
e
r

s
p
e
e
d
(
1
)
L
o
w
e
r

s
p
e
e
d
(
1
)
P
o
w
e
r

i
n
p
u
t
P
o
w
e
r

o
u
t
p
u
t
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
(1) preprogrammed speeds
Nominal data
B side A side
"V" "A" U

D
i
r
e
c
t
i
o
n

o
f

r
o
t
a
t
i
o
n
Fastening thread M4
Including line cord with plug
(450 mm long)
Axial impeller
p. 377
Connection lead
p. 374
Programming
device p. 375
(Basket) guard grille
p. 378
Wall ring
p. 379
Mounting angle
p. 381
319
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
D
154
m
3
/h
(2)
W
(3)
F C
Blade angle 22 130 Blade angle 28 130 Blade angle 34 130
160 1.0
115 0.4
74.0 27.5
240 1.8
170 0.6
72.0 31.0
360 3.4
260 1.3
71.5 32.0
640 11.0
460 4.0
70.0 35.0
140 0.6
95 0.2
74.0 27.5
210 1.1
140 0.3
72.0 31.0
310 2.1
210 0.6
71.5 32.0
550
(4)
6.9
365 2.0
70.0 35.0
610
(4)
10.3
405 3.0
69.0 37.0
280 2.5
200 1.0
69.5 36.0
410 5.0
295 1.8
69.0 37.5
700
(4)
12.5
500 4.6
66.0 43.0
170 0.8
110 0.2
71.5 32.0
240 1.6
160 0.5
69.5 36.0
350 3.2
235 1.0
69.0 37.5
600
(4)
7.9
400 2.3
66.0 43.0
m
3
/h
(2)
W
(3)
F C
200 1.3
145 0.5
71.5 32.0
320 3.5
230 1.3
66.5 42.0
500 8.6
360 3.1
65.0 45.0
860
(4)
14.7
615 5.3
62.5 50.0
190 1.1
130 0.3
69.0 37.0
270 2.2
180 0.7
66.5 42.0
420 5.4
290 1.6
65.0 45.0
740
(4)
9.3
495 2.7
62.5 50.0
m
3
/h
(2)
W
(3)
F C
220 1.7
160 0.6
69.0 37.0
rpm
1400
1000
1400
1000
1400
1000
1400
1000
1400
1000
1200
800
1200
800
1200
800
1200
800
1200
800
172
200
200
230
154
172
200
230
254
(2) Running at free air flow (3) Power requirement of impeller (4) Permitted with corresponding cooling of the motor (shaft power > output power)
Motor protection: Via electronics
Electrical connection: Line cord with plug
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL
Curves: Page 320
Speed settings: The pre-programmed upper speed is reached
with the speed relay open; lower speed is reached when the speed
relay is closed.
Speeds from 10% to 100% of the maximum speed can be preset
using the programming unit (see page 375). However, we recommend
not allowing it to fall below 600 rpm ( ) or 1000 rpm ( ).
Mounting: Guard grille and wall ring are mounted onto the protruding
thread ends of the A side.
Axial impeller mounting: Mounted to the motor shaft using a plastic
adapter with pulling peg and an M4 screw.
G E F D
Axial impellers
Power system: 115 or 230 VAC,
50/60 Hz
L1
N
black
blue
brown
1
2
5
Speed selection
115 or 230 VAC
L or N
Energy-
saving
motor
(ESM)
Electr.
connection:
320
Energy-saving motors (ESM)
Air performance curves
100 50 150 200 250 300 350
[
P
a
]
[m
3
/h]
5
10
15
20
25
30
35
22 2200 min
-1
: 28 34
22 1500 min
-1
: 28 34
100 200 300 400
[
P
a
]
[m
3
/h]
10
20
30
40
50
22 2200 min
-1
: 28 34
22 1500 min
-1
: 28 34
154, 2200 rpm / 1500 rpm 172, 2200 rpm / 1500 rpm
100 200 300 400 500
[
P
a
]
[m
3
/h]
10
20
30
40
22 2200 min
-1
: 28 34
22 1500 min
-1
: 28 34
200, 2200 rpm / 1500 rpm
A A
A
321
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
150 50 100 200 250
[
P
a
]
[m
3
/h]
4
8
12
16
20
24
22 1750 min
-1
: 28 34
22 1300 min
-1
: 28 34
154, 1750 rpm / 1300 rpm
150 50 100 200 250 300 350
[
P
a
]
[m
3
/h]
5
10
15
20
25
30
22 1750 min
-1
: 28 34
22 1300 min
-1
: 28 34
200 100 300 400 500
[
P
a
]
[m
3
/h]
10
20
30
40
50
22 1750 min
-1
: 28 34
22 1300 min
-1
: 28 34
172, 1750 rpm / 1300 rpm
200, 1750 rpm / 1300 rpm
B B
B
322
Energy-saving motors (ESM)
Air performance curves
200 100 300 400 500
[
P
a
]
[m
3
/h]
10
20
30
40
22 1550 min
-1
: 28 34
22 1100 min
-1
: 28 34
100 200 300 400 500 600 700
[
P
a
]
[m
3
/h]
5
10
15
20
25
30
35
22 1550 min
-1
: 28 34
22 1100 min
-1
: 28 34
200, 1550 rpm / 1100 rpm 230, 1550 rpm / 1100 rpm
C C
120 40 80 160 200
[
P
a
]
[m
3
/h]
4
8
12
16
22 1550 min
-1
: 28 34
22 1100 min
-1
: 28 34
150 50 100 200 250 300 350
[
P
a
]
[m
3
/h]
5
10
15
20
25
22 1550 min
-1
: 28 34
22 1100 min
-1
: 28 34
154, 1550 rpm / 1100 rpm 172, 1550 rpm / 1100 rpm
C C
323
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
40 80 120 160 200
[
P
a
]
[m
3
/h]
2
4
6
8
10
12
14
22 1400 min
-1
: 28 34
22 1000 min
-1
: 28 34
50 100 150 200 250 300
[
P
a
]
[m
3
/h]
4
8
12
16
20
24
22 1400 min
-1
: 28 34
22 1000 min
-1
: 28 34
154, 1400 rpm / 1000 rpm 172, 1400 rpm / 1000 rpm
D D
100 200 400 300
[
P
a
]
[m
3
/h]
5
10
15
20
25
30
22 1400 min
-1
: 28 34
22 1000 min
-1
: 28 34
600 200 400 800
[
P
a
]
[m
3
/h]
5
10
15
20
25
30
35
22 1400 min
-1
: 28 34
22 1000 min
-1
: 28 34
200, 1400 rpm / 1000 rpm 230, 1400 rpm / 1000 rpm
D
E
D
D
D
E
E
324
Energy-saving motors (ESM)
Air performance curves
40 80 120 160
[
P
a
]
2
[m
3
/h]
4
6
8
10
22 1200 min
-1
: 28 34
22 800 min
-1
: 28 34
50 100 150 200 250
[
P
a
]
2
[m
3
/h]
4
6
8
10
12
14
16
22 1200 min
-1
: 28 34
22 800 min
-1
: 28 34
154, 1200 rpm / 800 rpm 172, 1200 rpm / 800 rpm
100 200 300 400
[
P
a
]
[m
3
/h]
4
8
12
16
20
24
22 1200 min
-1
: 28 34
22 800 min
-1
: 28 34
100 200 300 400 500 600 700
[
P
a
]
[m
3
/h]
4
8
12
16
20
24
28
22 1200 min
-1
: 28 34
22 800 min
-1
: 28 34
200, 1200 rpm / 800 rpm 230, 1200 rpm / 800 rpm
F F
F G
325
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
100 200 300 400 500
[
P
a
]
[m
3
/h]
5
10
15
20
22 1200 min
-1
: 28 34
22 800 min
-1
: 28 34
254, 1200 rpm / 800 rpm
G
326
Energy-saving axial fans
Material: Wall ring: Plastic PP20TV
Blade: Sheet steel, coated in
black
Rotor: Coated in black
Number of blades: 5
Direction of air flow: "V", exhaust over
struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 44
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics
Electrical connection: Line cord with plug
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA
Speed: Using the programming unit
(see page 375), 2 speeds
between n
min
and n
max
can be programmed.
Nominal data
Type
subject to alterations
W1G200-EA91 -27 M1G055-BD
VAC Hz m
3
/h rpm W A dB(A) Pa C kg
115 50/60 500 1400 7 0.12 42 -30 to +50 1.0 A
W1G200-EA95 -47 M1G055-BD 115 50/60 800 2200 27 0.42 56 -30 to +50 1.0 B
W1G200-EA87 -25 M1G055-BD 230 50/60 500 1400 7 0.06 42 -30 to +50 1.0 A
W1G200-EA91 -45 M1G055-BD 230 50/60 800 2200 27 0.21 56 -30 to +50 1.0 B
C
u
r
v
e
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
A
i
r

f
l
o
w
S
p
e
e
d
/
r
p
m
P
o
w
e
r

i
n
p
u
t
C
u
r
r
e
n
t

d
r
a
w
S
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
M
a
x
.
o
p
e
r
a
t
i
v
e

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
Motor
100 200 300 400 500
0 50 [CFM] 100 150 200 250 300
[
P
a
]
10
0
,
0
5
0
,
1
0
0
,
1
5
0
,
2
0
[
i
n

H
2 O
]
[m
3
/h]
n
max.
= 1400 min
-1
n
min.
= 500 min
-1
20
30
40
50
100 300 700 500
0 [CFM] 100 200 300 400
[
P
a
]
20
0
,
1
0
,
2
0
,
3
0
,
4
[
i
n

H
2 O
]
[m
3
/h]
n
max.
= 2200 min
-1
n
min.
= 800 min
-1
40
60
80
100
Curves (programmable) Curves (programmable)
A B
327
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
"V"
Including line cord with plug
(450 mm long)
Electr.
connection:
Power system: 115 or 230 VAC,
50/60 Hz
L1
N
black
blue
brown
1
2
5
Speed selection
115 or 230 VAC
L or N
Energy-
saving
motor
(ESM)
Connection lead
p. 374
Programming
device p. 375
Mounting angle
p. 381
328
329
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC-SYSTEMS
HMS controller 358
Accessories: Temperature sensor / control module, pressure control, selection module, interface converter, ... 340
External commutation electronics for rail technology 338
Switch power supplies 334
Options 330
330
EC-SYSTEMS
Options
EC fans 24 / 48 VDC
with integrated commutation electronics
Linear input:
< 1 VDC -> n=0
1 VDC -> n
min
10 VDC -> n
max
PWM input:
< 10% PWM -> n=0
10% PWM -> n
min
100% PWM -> n
max
EC fans 48 VDC
with integrated commutation electronics
Linear input:
< 1 VDC -> n=0
1 VDC -> n
min
10 VDC -> n
max
PWM input:
< 10% PWM -> n=0
10% PWM -> n
min
100% PWM -> n
max
EC fan
PWM and Lin 0-10 VDC
Control input Lin 0-10 VDC
PWM
24 / 48 VDC
Tach output
red
blue
yellow
white
EC fan 48 VDC
PWM and Lin 0-10 VDC
Power supply 230 VAC / 48 VDC
Optional board (built-in):
3 speed steps
Constant air flow
RS485 / ebmBUS
Control input Lin 0-10 VDC or
selector switch
Selector switch
PC with interface
converter (RS485)
230 VAC, 50 / 60 Hz
red
blue
yellow
white
EC fans
with external commutation electronics
650 W, 110 VDC (rail technology)
EC fan Commutation electronics 650 W
110 VDC
PC with interface
converter (RS485)
Actual value 0-10 VDC
(e.g. pressure, temperature, air flow,
air speed, moisture, CO
2
)
Control input Lin 0-10 VDC
Potentiometer for set values
Tach output
Alarm
Controller enabling 10-100 VDC
10-253 VAC
331
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC fans (motor size 055)
with integrated commutation electronics
1~ 115 VAC or 230 VAC
50/60 Hz mains operation
EC fans (motor size 074)
with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC
50/60 Hz mains operation
EC fan with integrated electronics
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
Tach output
Supply for potentiometer 10 V
Slave output
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
EC fans (motor size 084)
with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC
50/60 Hz mains operation
EC fan with integrated electronics
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
Alarm
Supply for potentiometer 10 V
Slave output
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
332
EC-SYSTEMS
Options
EC fans (motor size 084, ebmBUS)
with integrated commutation electronics
1~ 200-277 VAC,
50/60 Hz mains operation
EC fan with integrated electronics
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
On/off and alarm
output 15 V
EC fans (motor size 112/150)
with integrated commutation electronics
1~ 200-277 VAC or
3~ 200-240 / 380-480 VAC
50/60 Hz mains operation
EC fan with integrated electronics
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
Actual value input 4-20 mA
Alarm
Supply for potentiometer 10 V
Slave output
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
Supply for external sensor 20 V
333
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC-SYSTEMS:
Networked EC fans with interface
converter and repeater
EC fan Electronics Interface converter
and repeater
Customer PC with LISA
5.1 control software
Control software
part no.
25711-2-0199
Features of control
software LISA 5.1
Individual control
and monitoring of
max. 7,905 fans
Group-oriented
arrangement of the fans
Level 1: Overview
display for 10 floors
Level 2: Overview
display for 255 groups
Level 3: Overview
display for 31 fans
within a group
Broadcast command for
a group or all fans
Speed, temperature or
pressure control
Alarm signal
Interface converter
part no. 21487-1-0174
Power supply 150 W
integrated electronics
integrated electronics
Repeater
part no.
25708-1-0174
Repeater
max. 31
addresses
max. 31
addresses
max. 31
addresses
integrated electronics
334
Switch power supply with PFC, basic version
48 VDC, 150 W / 300 W
General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
Material: Housing made of stainless steel
Protection class: I
Type of protection: IP 20 (acc. to EN 60529)
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Product conforming to standards: EN 50178, CE
Approvals: UL/CSA (File No. E 181381)
Nominal data
Type
CNW015-AB06 -01
CNW015-AB02 -01
CNW030-AC06 -01
CNW030-AC02 -01
subject to alterations
80
108
1
0
b ca
e
5
d
f
VAC Hz VDC W A kg
1~ 115 50/60 48 150 3.10 0.7
1~ 230 50/60 48 150 3.10 0.7
1~ 100-120 50/60 48 300 6.25 1.3
1~ 200-277 50/60 48 300 6.25 1.3
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
O
u
t
p
u
t

v
o
l
t
a
g
e
M
a
s
s
O
u
t
p
u
t

P
1
m
a
x
.
R
a
t
e
d

o
u
t
p
u
t

c
u
r
r
e
n
t
Dimensions
a b c d e f
187 176 167 50 110 1
187 176 167 50 110 1
272 260 251 66 112 2
272 260 251 66 112 2
335
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
+48
V
GND
+48
V
GND L N PE
Line side Motor side
Blower 1
exhaust air
Blower 2
exhaust air
blue red blue red
336
Switch power supply with PFC, RS485 and ebmBUS
48 VDC, 150 W / 300 W
General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
Material: Housing made of stainless steel
Protection class: I
Type of protection: IP 20 (acc. to EN 60529)
EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Product conforming to standards: EN 50178, CE
Approvals: UL/CSA (File No. E 181381)
Technical features: Control board for RS485, ebmBUS and LISA functions
Nominal data
Type
CNW015-AB06 -05
CNW015-AB02 -05
CNW030-AC06 -05
CNW030-AC02 -05
subject to alterations
80
108
1
0
b ca
e
5
d
f
VAC Hz VDC W A kg
1~ 115 50/60 48 150 3.10 0.7
1~ 230 50/60 48 150 3.10 0.7
1~ 100-120 50/60 48 300 6.25 1.3
1~ 200-277 50/60 48 300 6.25 1.3
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
O
u
t
p
u
t

v
o
l
t
a
g
e
M
a
s
s
O
u
t
p
u
t

P
1
m
a
x
.
R
a
t
e
d

o
u
t
p
u
t

c
u
r
r
e
n
t
Dimensions
a b c d e f
187 176 167 50 110 1
187 176 167 50 110 1
272 260 251 66 112 2
272 260 251 66 112 2
337
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
RS485 RS485
L N PE
Line side Motor side
+48
V
GND
+48
V
GND
Tach PWM
white yellow
blue red
RS232
RS485
Interface converter
Blower
~
To next switch
power supply
2 x RJ45:
PIN 5 - RS B
PIN 6 - RS A
338
External commutation electronics
for rail technology, 110 VDC, 650 W
General remarks: For EC motors and fans with 3 cores and without integrated
commutation electronics
Function: Commutation unit for three-core EC motors up to a power input of 650 W.
Various basic functions are integrated: open loop speed control, closed loop speed control,
RS485 interface. In combination with sensors, all control tasks as required in air technology
can be executed.
Protection class: I
Type of protection: IP 20 (acc. to DIN EN 60529)
NB: Connected fans have to be designed for a rated voltage of 127 VDC!
Nominal data
Type
CEG 485-HB50 -01
subject to alterations
4
0
146,5
1
,
5
6
3
179,5
5
,
5
6
4
1
9
3
6
3
190
1
,
5
2
,
26
8
169
VDC W A C kg
110 650 5.9 -25 to +40 2.0
N
o
m
i
n
a
l

v
o
l
t
a
g
e
P
o
w
e
r

i
n
p
u
t
P
1
m
a
x
.
C
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
EMC / EMI: Acc. to EN 50155 and EN 50121
Legislation: Low voltage directive 73/23/EEC, VDE 0160/EN 50178
Design:
Motor output protected against short circuit phase to phase and conditionally
phase to earth
0-10 V input (Ri: 100 k)
0-10 V input (Ri: 100 k) for connection of external actual value input
RS485 interface (ebmBUS)
Floating alarm contact 250 VAC / 5A, during alarm, relay is released (low-active)
Wide voltage input for external controller enabling via RESET function
Tach output
LED for operation and alarm mode
green: unit on
red: alarm
Setting of minimum and maximum values via potentiometer
Operational modes (to be set via DIP switch):
Open loop speed control
Closed loop speed control
Controlling external parameters
Direction of motor rotation reversible
Connectors for external electronics:
KL1 2-pole connector; centreline 7.5; Co. Wago part no.: 231-202/026-000
KL2A 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
KL2B 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
KL3A 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL3B 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL4 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL5A 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL5B 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL6 3-pole connector; centreline 7.5; Co. Wago part no.: 731-603
339
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
RS B Interface connection RS B
RS A Interface connection RS A
KL2B
RS B Interface connection RS B H2 Hall-sensor 2
An, Tacho Tach output, open collector H3 Hall-sensor 3
GND Reference KL2 (for KL2 only) Shielding connection
+18 V +18 V (non-stabilised, +20%, 20 mA) for supplying
external sensors
Shielding connection
KL5B H+ Power supply for hall-sensors (+)
Sensor 1 Input for external sensor, Ri = 100 k H+ Power supply for hall-sensors (+)
GND Reference KL2 (for KL2 only) TW / PTC Thermal switch or PTC connection
+10 V +10 V (stabilised +/- 3 %, 25 mA) H- Power supply for hall-sensors (-)
0-10 V Input for set value 0 - 10 V, Ri = 100 k H- Power supply for hall-sensors (-)
GND Reference KL2 (for KL2 only) KL6 U Motor winding U
V Motor winding V
W Motor winding W
Connector Connection Assignment / function Connector Connection Assignment / function
PE1 KL3A
KL3B
KL4
KL5A
Ground connection
PE2 Ground connection
KL1 + 110 VDC
110 VDC -
KL2A RS A Interface connection RS A
NO Relay contact for alarm, make for failure
COM Relay contact for alarm
NC Relay contact for alarm, break for failure
COM Relay contact for alarm
EN + Enable input via RESET function
EN - Enable input via RESET function
H1 Hall-sensor 1
+ -
RS
A
RS
B
RS
A
RS
B
An
Tacho
GND NO COM
EN
+
EN
-
H1 H2 H3 NO
NC COM
PE1 PE2
KL2B
KL2A
KL3B
KL3A
KL5B
KL5A KL6 KL4 KL1
GND
0-10
V
+10
V
+18
V
GND
Sensor
1
H+ H+
TW
PTC
H- H-
U V W
340
Temperature sensor
Electr. connection:
Output voltage depending on temperature:
Tolerance 3 K
Nominal data
Part no.
50005-1-0174
subject to alterations
8
3
,
3
3,5
7
+0,5
1

0
,1
2
,
5
3
+0,2

4
,
9
6
,
9
1
3
5
84,7
45
37,5
6,5
38,5
4
5
0
85
6
+
2
0
VDC mA VDC mA k C kg
15-30 10 0-10 1.0 1.1 -20 to +80 0.02
N
o
m
i
n
a
l

v
o
l
t
a
g
e
C
u
r
r
e
n
t

d
r
a
w
O
u
t
p
u
t

v
o
l
t
a
g
e
T
e
m
p
e
r
a
t
u
r
e

m
e
a
s
u
r
i
n
g

r
a
n
g
e
M
a
s
s
O
u
t
p
u
t

c
u
r
r
e
n
t
O
u
t
p
u
t

i
m
p
e
d
a
n
c
e
Output (yellow)
+ (red)
(blue)
Core-end sleeve
blue
yellow
red
0-10 VDC
output
15-30 VDC
Temperature sensor
U/V
10
0
-20 80 Temp. C
341
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
Temperature control module
Electr. connection:
Control function: Both designs have "cooling" as control function
Tolerance 3 K
Nominal data
Part no.
50002-1-0174
50003-1-0174
subject to alterations
8
3
,
3
3,5
7
+0,5
1

0
,1
2
,
5
3
+0,2

4
,
9
6
,
9
1
3
5
84,7
45
37,5
6,5
38,5
4
5
0
85
6
+
2
0
N
o
m
i
n
a
l

v
o
l
t
a
g
e
C
u
r
r
e
n
t

d
r
a
w
O
u
t
p
u
t

v
o
l
t
a
g
e
O
u
t
p
u
t

c
u
r
r
e
n
t
O
u
t
p
u
t

i
m
p
e
d
a
n
c
e
Output (yellow)
+ (red)
(blue)
Core-end sleeve
blue
yellow
red
blue
yellow
white
red
Counter
Controller
Alarm
Speed display
Temperature control module
50002-1-0174
VDC mA VDC mA k C kg
18-60 10 2-10 0.1 6.8 +30 to +55 0.02
18-60 10 0-10 0.1 6.8 +10 to +45 0.02
T
e
m
p
e
r
a
t
u
r
e

c
o
n
t
r
o
l

r
a
n
g
e
M
a
s
s
2-10 VDC
or 0-10 VDC
output
18-60 VDC
Connection Fans
Maximum ripple
3.5 %
Control input
0 - 10 VDC
Tach output,
pulses per revolution
GND
47 K
680
4
7

K
47 V
I
sink
max.
10 mA
U/V
10
2
0 30 55 Temp. C
50003-1-0174
U/V
10
1
0 10 6 45 Temp. C
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
342
Pressure control with integrated pressure sensor
Functions: Integrated PID controller, day/night/linear set point preset, integrated set point
potentiometer for day and night, external set point preset via potentiometer
Pressure sensor: 0-500 Pa, bursting strength 200 mbar, for non-aggressive
gaseous media
Type of protection: IP 55
Nominal data
Type
CCC 000-AC04 -01
subject to alterations
195
1800,4
7,5
5,5
1
0
1
2
5
4
3
1
0
,
5
1
,
5
1
1
5
9
5

0
,
2
8
9
,
5
3
5
,
5
162
167
pressure controller IP55
100-277 VAC 50/60 Hz
pressure range 0-500 Pa
VAC Hz VDC Pa C
1~ 100-277 50/60 20 @50 mA 50-500 -25 to +60
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e
F
r
e
q
u
e
n
c
y
N
o
m
i
n
a
l

v
o
l
t
a
g
e
,
a
l
t
e
r
n
a
t
i
v
e
P
r
e
s
s
u
r
e

c
o
n
t
r
o
l

r
a
n
g
e
P
e
r
m
.
a
m
b
.
t
e
m
p
.
343
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Connector Assignment / function
ST8
Relay contact for alarm
ST7
ST2
ST1
Connector Assignment / function
ST4
Selector switch terminal
Set value potentiometer
GND
ST3
GND
Connection
COM
Relay contact for alarm, break for failure NC
Relay contact for alarm COM
Relay contact for alarm, break for failure NC
N
L
Mains 50/60 Hz, neutral
Mains 50/60 Hz, phase
Protective earth PE
N
L
Mains 50/60 Hz, neutral
Mains 50/60 Hz, phase
Protective earth PE
Connection
GND
Selector switch terminal Night
Selector switch terminal GND
Selector switch terminal Day
GND
Set value potentiometer 0-10 V PWM
Set value potentiometer,
supply 10 V (-10 %), 10 mA
+10 V
GND
Control voltage for fan, 0-10 V OUT
Tach output from fan Tach
GND
DC voltage supply (optional),
with reverse polarity protection
20 V IN
P
E
LN
P
E
LN
ST1 ST2
N
C
C
O
M
ST7
N
C
C
O
M
ST8
2
0

V

I
N
G
N
D
ST3
T
a
c
h
O
U
T
G
N
D
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
D
a
y
G
N
D
N
i
g
h
t
G
N
D
ST4
Control terminals Line terminals
Mains Alarm
Set value
potentiometer Selector switch
Fan
Day Linear
Night
344
Selection module for 3 speeds
General remarks: Using an external selector switch, one of three preset speeds
can be chosen. Presetting is done via one integrated potentiometer each.
Material: Plastics
Type of protection: IP 20
Type
CBC 000-AE04 -01
subject to alterations
50
2
4
9
0
345
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Electr.
connection:
Selector switch
+10 V
Day
Night
Party
+10 V
0-10 V output
GND
red
yellow
blue
Fan
Connection
fan
Connection
selector switch
346
Interface converter RS232 - RS485
General remarks: This interface converter permits bi-directional connection of
RS232 devices (laptop or PC) with ebmBUS devices (electronic commutation units with
RS485 interface)
Safety: Electrical insulation between the RS232 and RS485 side is provided
Material: Plastic housing for standard rail mounting according to DIN EN 50022-35
Status display: Via LEDs
green: supply voltage OK
red: data exchange
Mode of operation: RS485 2-wire mode with echo and automatic control
Galvanic insulation: Min. 1kV insulation voltage between RS232 and RS485 interfaces and
between power supply and interfaces
ESD immunity: Up to 15 kV (acc. to IEC 801-2, Stage 4)
Delivery scope: Interface converter
Supply plug unit (230 VAC / 12 VDC, 500 mA)
Adaptor leads with 2 x 9-pole SUB-D sockets
Adaptor leads with 9-pole SUB-D socket
Screw terminal RS485
Nominal data
Part no.
21487-1-0174
subject to alterations
2
2
1
0
5
75
M
L
+
RS232 RS485
VAC VAC / VDC mA kg
1~ 230 12-24 150 0.4
N
o
m
i
n
a
l

v
o
l
t
a
g
e

p
o
w
e
r

s
u
p
p
l
y
S
u
p
p
l
y

v
o
l
t
a
g
e
M
a
s
s

(
i
n
c
l
.
P
S
)
C
u
r
r
e
n
t

d
r
a
w

a
t

n
o
-
l
o
a
d

o
p
e
r
a
t
i
o
n
347
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Interface converter RS232 - RS485
General remarks: This interface converter permits bi-directional connection of
RS232 devices (laptop / PDA) with ebmBUS devices (electronic commutation units with
RS485 interface). Power supplied by RS232 of the laptop / PDA.
Material: Plastic housing
Status display: Via LEDs
PWR: Power supply
TXD: Data transfer (send)
RXD: Data transfer (receive)
Mode of operation: RS485 2-wire mode with echo and automatic control
Delivery scope: Interface converter, English-language operating manual
Electrical terminals: Screw terminal, TRX+ = RSA, TRX = RSB
Nominal data
Part no.
21495-2-0174
subject to alterations
1
9
7
4
37
GND RX- RX+ TX+ TX-
TRX- TRX+
P
W
R
T
X
D
R
X
D
R
S
4
2
2
R
S
4
8
5
kg
0.1
M
a
s
s
348
RS485 repeater
General remarks: The physical RS485 repeater is used for the connection of two segments
on an RS485 basis. It can split a segment with network bus wires that are too long, or with
too many nodes into two smaller, standardised units. A maximum of 31 nodes can be
connected to the repeater.
Installation: The repeater housing is mounted on the wall or in the cable duct with two
screws ( 4 mm) or with cable ties.
Material: Housing made of galvanised sheet steel
Type of protection: IP 20 according to DIN EN 60529
Type of transceiver: 2 x ANSI standard RS485 transceiver
Galvanic insulation: Operating insulation 500 V between both channels
Network connection: Screw terminals
Mains connection: Wieland connector GST 18/3 (part of delivery)
Pin configuration of network:
Nominal data
Part no.
25708-1-0174
subject to alterations
B
us1
B
us1
B
us2
B
us2

4
.
3
3
1
9
0
30
38
5
0
2
0
0
VAC Hz VA C C kg
1~ 200-277 50/60 < 3 0 to +50 -20 to +70 0.3
S
u
p
p
l
y

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
P
o
w
e
r

i
n
p
u
t
M
a
s
s
P
e
r
m
.
o
p
e
r
a
t
i
n
g

t
e
m
p
.
P
e
r
m
.
s
t
o
r
a
g
e

t
e
m
p
.
LED
Supply connection
M
a
tin
g
c
o
n
n
e
c
to
r
G
S
T
1
8
/
3
W
ie
la
n
d
B
a
m
b
e
r
g
s
c
r
e
w
te
r
m
in
a
l
BUS2 BUS1
A
B B
A
12 3 4 5 6 7 8 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1
Pin No. Assignment / function
1 - 4
5
not assigned
Connection RS485, line B
6 Connection RS485, line B
7, 8 not assigned
(each looped through within BUS1 and BUS2)
349
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
RS485 terminal box with lead connections
for centrifugal fans with EC motor size 084 (ebmBUS, RS485)
General remarks: RS485 terminal box with
2x RJ45 sockets for ebmBUS
ebmBUS line with Molex Mini-Fit female connector for connection to the motor
3-pole 4-pin unit connector with AMP Mate-N-Lock female connector to
connect to motor
Mode of operation display (LED2 green) and alarm display (LED 1 red)
Delivery scope:
Terminal Box
Supply line (800 mm)
ebmBUS line (800 mm)
Material: ABS (fire rating V0 according to UL)
Pin configuration of supply lead:
Pin configuration of ebmBUS lead:
Pin configuration of RJ45 sockets:
Part no.
54002-4-1040
subject to alterations
4
9
9
61
8
8
58
61.6
73
1
1
1
45.4
8
7
9
9
61
57
Mounting dimensions
Colour Assignment / function
green/yellow
black 2
PE
N
black 1 L
Colour Assignment / function
yellow
white
RS A
RS B
red Operation: +15 V Alarm: 0 V
blue Operation: 0 V Alarm: +15 V
Pin No. Assignment / function
5
6
RS B
RS A
350
Hand-held control terminal
General remarks: Terminal to control networked fans and to set their parameters;
RS485 (ebmBUS)
Type of protection: IP 20 (acc. to DIN EN 60529)
Protection class: III
Display: Plain text LCD, 2x8 characters
Accumulator and charging electronics: 2 x round cell R6 DIN 40863 NiMH 1,500 mAh,
operating time approx. 40 hrs, standby time approx. 100 days, charging time max. 4 hrs.
Parts included in delivery: Hand-held control terminal, power supply and accumulator
unit, BUS cable, 2 x round cell R6 NiMH 1,500 mAh
Nominal data
Type
CBC 000-AB06 -01
subject to alterations
9
5
44 68
VAC Hz VDC C C kg
1~ 100-240 50/60 12 0 to +45 -20 to +65 0.4
N
o
m
i
n
a
l

v
o
l
t
a
g
e

r
a
n
g
e

p
o
w
e
r

s
u
p
p
l
y
F
r
e
q
u
e
n
c
y
S
u
p
p
l
y

v
o
l
t
a
g
e
M
a
s
s
P
e
r
m
.
s
t
o
r
a
g
e

t
e
m
p
.
P
e
r
m
.
a
m
b
.
t
e
m
p
.
351
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
352
Speed setting device
with housing
Material: Housing made of plastic
Type of protection: IP 54
Design: The speed setting device can be operated with the entire range of ebm-papst
EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal
that allows infinitely variable open loop speed control. The control also permits fan speed
measurement using a multimeter equipped with a frequency meter (for which a tach output
is given from the fan).
Cable inputs: 4 x M16 or M20
Mounting holes: Suitable for 4 mm mounts
Speed measurement: Connect a frequency meter to the connection points
(labelled + and -) on the PCB board. The fan has an output of 1 pulse per
revolution, so that the measured frequency can be converted into rpm using
the following equation:
rpm = frequency (Hz) x 60
Comment:
A single controller can be used to control multiple fans with the same speed setting.
The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
If the tach cable is required, this device can only be connected to one fan. Note that in
rare operating cases, it is possible that permanent connection of the tach cable can
cause a slight decrease in the maximum speed.
Nominal data
Type
CLC 000-AE04 -01
subject to alterations
2
6
5
8
6
5
65
25
50
5
0
VDC mA k C kg
10 1.1 0-10 Lin 50 0.10
S
u
p
p
l
y

v
o
l
t
a
g
e
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
R
e
s
i
s
t
a
n
c
e
M
a
s
s
+ meter connection
meter connection
353
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Electr.
connection:
+10 V
Control
GND
Tacho
r
e
d
y
e
l
l
o
w
b
l
u
e
w
h
i
t
e
r
e
d
y
e
l
l
o
w
b
l
u
e
w
h
i
t
e
Fan 1 Fan 2
red
yellow
blue
white
+10 V
Control
GND
Tacho
354
Speed setting device
without housing
Design: The speed setting device can be operated with the entire range of ebm-papst
EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal
that allows infinitely variable open loop speed control. The control also permits fan speed
measurement using a multimeter equipped with a frequency meter (for which a tach output
is given from the fan).
Mounting hole: 10 mm
Speed measurement: Connect a frequency meter to the connection points
(labelled + and -) on the PCB board. The fan has an output of 1 pulse per
revolution, so that the measured frequency can be converted into rpm using
the following equation:
rpm = frequency (Hz) x 60
Comment:
A single controller can be used to control multiple fans with the same speed setting.
The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
If the tach cable is required, this device can only be connected to one fan. Note that in
rare operating cases, it is possible that permanent connection of the tach cable can
cause a slight decrease in the maximum speed.
subject to alterations
1
2
2
2
5
0
3
6
2
8
36
28
4 x 3,5
Nominal data
Type
CLC 000-AD04 -01
VDC mA k C kg
10 1.1 0-10 Lin 50 0.05
S
u
p
p
l
y

v
o
l
t
a
g
e
M
a
x
.
c
u
r
r
e
n
t

d
r
a
w
P
e
r
m
.
a
m
b
.
t
e
m
p
.
M
a
s
s
R
e
s
i
s
t
a
n
c
e
+ meter connection
meter connection
355
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Electr.
connection:
+10 V
Control
GND
Tacho
r
e
d
y
e
l
l
o
w
b
l
u
e
w
h
i
t
e
r
e
d
y
e
l
l
o
w
b
l
u
e
w
h
i
t
e
Fan 1 Fan 2
red
yellow
blue
white
+10 V
Control
GND
Tacho
356
LISA
Control software for EC-SYSTEMS
Version: LISA 5.1
Features:
Individual control and monitoring of 7,905 fans
Group-oriented arrangement of the fans
Level 1: Overview display for 10 floors
Level 2: Overview display for 255 groups within a floor
Level 3: Overview display for 31 fans within a group
Broadcast command for one group or all fans
Speed, temperature or pressure control
Error message
Suitable for: EC motors and electronics with ebmBUS
System requirements: Windows 2000 / XP
Part no.
25711-2-0199
subject to alterations
357
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Fan Control
Control software & accessories for Pocket PCs / PDAs
Version: Fan Control 1.00
Features:
Managing up to 31 fans
Setting pre-set values and indicating actual values
Setting parameters for PID control
Setting fan address
Setting mode of operation (heating/cooling)
Alarm diagnosis
Language selection for user interface
Delivery scope: Installation-CD, interface converter (RS232-RS485), BUS cable,
installation instruction and detailed manual (PDF). The Pocket PC / PDA and compatible
serial communication cables are not included in the scope of delivery.
Suitable for: EC motors and electronics with ebmBUS
System requirements: Pocket PC / PDA with Windows Mobile 5.0, RS232 interface,
and serial communication cable.
Compatible Pocket PCs / PDAs: (as of 2006-09-14)
Hewlett-Packard rx1950
Hewlett-Packard hx2190
Fujitsu-Siemens Pocket Loox C550
Dell Axim x51v (624 MHz)
Refer to our website at www.ebmpapst.com/downloads for a continuously updated list of
approved Pocket PCs / PDAs along with the suitable serial communication cables.
Part no.
21500-1-0174
subject to alterations
Set and actual values Mode of operation
Fan address Graphic setting
358
HMS controller
General remarks: The HMS controller is governed by a microprocessor and is specifically
designed for Heat Management Systems (= HMS). This controller allows for an almost
limitless programming variety as regards customer-specific fan speed / temperature
profiles. Moreover, this controller offers a multitude of the most diverse alarm
configurations.
Our HMS controller has been specially designed and adjusted to the product range of
ebm-papst in Mulfingen. Thus, any size of our fans or blowers can be used.
The most diverse of applications needing temperature-dependent control are possible.
Among these are applications in telecommunication and the IT industry, in refrigeration
and air-conditioning as well as in specific industrial plants and systems.
Features:
4 fan speed / temperature characteristics that can be programmed independently
of each other
2 programmable no-frost relays for connecting 115 / 230 VAC heating devices
5 programmable alarm relays (with time lag):
- Temperature alarm (over / under-temperature)
- Fan good / bad alarm programming
- Temperature sensor alarm
- Programmable depending on signal inputs
4 programmable status outputs (with time lag):
- With "open collector" design to connect optical or acoustic displays / alarms
- Each fan speed can be set individually
4 signal inputs for external switches / limit switches
Connection of two independent temperature sensors (NTCs) possible
RS232 interface galvanic insulated
Selective protection of each fan
Programming via Windows software
(terminal program version 15 ff.: part no. 25710-2-0199)
Requirements:
Supply voltage of HMS controller: 16-57 VDC
Fans with standard interface
- 24 / 48 VDC fan voltage
- PWM / linear control input (0-10 V)
- Open collector tach output
NTC with R
25
= 33 k (EPCOS type M 891/33k/J)
System requirements: Windows 2000 / XP
Safety: According to EN 50178
EMC / EMI: Interference immunity EN 61000, interference emission EN 50081-1
Nominal data
Type
CCC 000-AA05 -03
subject to alterations
100
81
7
.
2
5
1
6
0
7
5
.
5
7
0
(1) without fans (2) per fan at nominal voltage
VDC W W A C kg
16-57 10 130 0.175 -40 to +70 0.15
S
u
p
p
l
y

v
o
l
t
a
g
e
P
o
w
e
r

i
n
p
u
t
(
1
)
,
m
a
x
.
P
o
w
e
r

i
n
p
u
t
(
2
)
,
m
a
x
.
C
u
r
r
e
n
t

d
r
a
w
(
1
)
m
a
x
.
M
a
s
s
P
e
r
m
.
a
m
b
.
t
e
m
p
.
359
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
F1 3,15 A * / 250 V
F2 3,15 A * / 250 V
F3 3,15 A * / 250 V
F4 3,15 A * / 250 V
* time lag fuse
Hall
F5 3,15 A * / 250 V
16 - 57 VDC
1
K4 K3 K5 K6 K7
L1
H1
H2
N
N
N
Alarm 1
F7 10 A * / 250 V
Alarm 3
Alarm 2
Alarm 5
Alarm 4
F6 10 A * / 250 V
K2
K1
Fan 4
PWM
Fan 1
Fan 3
Fan 2
Heater 2
Heater 1
Hall PWM
Hall PWM
Hall PWM
designation 9-pole Sub-D
RS-232
electrically insulated
1
2 4 3 5 7
Alarm
contact
2
0-57 V / 10 mA
1
1
Status
2 3 4 1

NTC 1
3 4 1

NTC 2
1
TD RD
DTR GND
RTS
360
361
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Accessories
Terminal boxes, capacitors, speed setting devices, motor protection switches, star-delta switches, repair switches 381
Accessories for Q-motors and energy-saving motors (ESM) 374
Connection lines 374
Wall rings 372
Guard grilles, streamers 362
362
Guard grille
a
c

e
h
g
b
Material: Steel, phosphated and coated
in black plastic
Basket guard grille for S series axial fans
Part no. Size
64536-2-4039
a b c d e f g h
74370-2-4039
64379-2-4039
74351-2-4039
64562-2-4039
74331-2-4039
64559-2-4039
74316-2-4039
64558-2-4039
74301-2-4039
64557-2-4039
64556-2-4039
64555-2-4039
74251-2-4039 250
300
300
300
300
315
315
330
330
350
350
400
400
420
420
450
450
450
450
19112-2-4039 250
19111-2-4039 250
19110-2-4039 200
AC motor EC motor
068 074
(1)
068 074
(1)
068 074
(1)
068 074
(1)
068
074
074
(2)
3.9 6.5 4.3 260.0 25.0 229.0 39.0
3.9 6.5 4.5 300.0 25.0 271.0 38.0
3.9 6.5 4.5 300.0 25.0 271.0 53.0
5.0 6.2 4.2 300.0 125.0 265.0 38.0
4.5 4.3 4.3 360.0 58.0 329.5 50.0
4.5 4.3 4.3 360.0 58.0 329.5 26.0 50.0
5.0 6.5 6.5 360.0 90.0 324.0 50.0
074
(2)
5.0 4.2 4.2 360.0 125.0 331.0 10.0 60.0
068 4.5 6.5 4.5 375.0 58.0 336.5 30.0 80.0
074
(2)
5.0 6.4 4.2 375.0 125.0 344.0 35.0 85.0
068 4.5 6.5 4.5 410.0 58.0 354.5 30.0 80.0
074
(2)
5.0 6.4 4.2 410.0 125.0 370.0 35.0 85.0
068 5.0 6.5 4.5 422.0 58.0 374.0 30.0 80.0
074
(2)
5.0 6.4 4.2 422.0 125.0 378.0 35.0 85.0
074 5.0 9.0 6.5 470.0 90.0 414.0 30.0 80.0
084
(2)
5.0 9.0 6.5 470.0 164.0 420.0 30.0 80.0
074 5.0 9.0 6.5 502.0 90.0 452.0 30.0 80.0
094 5.0 9.0 6.5 502.0 115.0 452.0 30.0 60.0
074 5.0 9.0 6.5 522.0 90.0 476.0 30.0 80.0
084
(2)
5.0 9.0 6.5 522.0 164.0 482.0 30.0 80.0
094
(3)
6.0 9.0 6.5 522.0 115.0 472.0 17.5 67.5
094
(4)
7.0 9.0 7.0 515.0 115.0 472.0 16.5 80.0
64570-2-4039
64378-2-4039
74372-2-4039
25943-2-4039
25938-2-4039
(1) DC-fed (2) Mains-powered (3) Blades made of plastic (4) Blades made of sheet steel subject to alterations
363
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
62622-2-4039
09414-2-4039
62623-2-4039
74250-2-4039
09415-2-4039
62624-2-4039
72320-2-4039
64052-2-4039
74300-2-4039
64491-2-4039
74315-2-4039
64490-2-4039
74330-2-4039
64563-2-4039
74350-2-4039
64538-2-4039
74373-2-4039
64539-2-4039
74374-2-4039
25950-2-4039
Guard grille
c

f
a
h
g
b
Material: Steel, phosphated and coated
in black plastic
Guard grille for S-series axial fans
Part no.
18656-2-4039
subject to alterations
Size a b c d e f g h
250
250
300
300
300
300
300
315
315
330
330
350
350
400 / 420
400
450
450
450
250
200
200
AC motor EC motor
068
074
(1)
068
074
(2)
068
074
(1)
074
(1)
3.9 4.6 4.6 245.0 58.0
3.9 4.6 4.6 245.0 58.0
3.9 4.6 4.6 290.0 58.0
3.9 4.6 4.6 290.0 58.0
5.0 4.2 4.2 290.0 125.0
3.9 4.6 4.6 360.0 58.0
3.9 4.6 4.6 360.0 58.0
068 4.5 4.3 4.3 360.0 58.0 329.0 26.0 26.0
074 5.0 6.5 6.5 360.0 90.0
074
(2)
5.0 4.2 4.2 360.0 125.0
068 4.5 6.4 4.3 375.0 58.0 336.0 33.0 30.0
074
(2)
5.0 6.4 4.2 375.0 125.0 344.0 35.0 35.0
068 4.5 6.4 4.3 410.0 58.0 371.0 30.0 30.0
074
(2)
5.0 6.4 4.2 410.0 125.0 370.0 35.0 35.0
068 5.0 6.5 4.5 422.0 58.0 374.0 30.0 30.0
074
(2)
5.0 6.4 4.2 422.0 125.0 378.0 35.0 35.0
074 5.0 9.0 6.5 502.0 90.0 452.0 30.0 30.0
084
(2)
5.0 9.0 6.5 502.0 164.0 458.0 30.0 38.0
074 5.0 9.0 6.5 522.0 90.0 476.0 30.0 30.0
084
(2)
5.0 9.0 6.5 522.0 164.0 482.0 30.0 38.0
094 7.0 9.0 7.0 560.0 115.0 517.0 16.5 38.0
(1) DC-powered (2) Mains-powered
364
Guard grille

d
a
h

e
g
c
6,4 Material: Steel, phosphated and coated
in black plastic
Wall rings: See p. 373
Comment: Contact us for article numbers
for complete fans.
Guard grille for S series fans (for nozzle-side mounting to square wall ring with long nozzle)
Part no. Size a c d e g h
26510-2-4039
74376-2-4039
35806-2-4039
35805-2-4039 450
450
450
450
74377-2-4039 400
35804-2-4039 400
35803-2-4039 400
AC motor EC motor
074 (4 poles)
074 (6 poles)
084
(2)
074 (6 poles)
084
(2)
094
074 (4 poles)
5.0 6.5 413.0 90.0 16.0
5.0 6.5 413.0 90.0 30.0 28.0
5.0 6.5 413.0 164.0 30.0 48.0
5.0 6.5 466.0 90.0 25.0
5.0 6.5 466.0 90.0 20.0 30.0
5.0 6.5 467.0 164.0 30.0 48.0
7.0 7.0 466.0 115.0 16.5 41.0
(2) mains-powered subject to alterations
Typical installation
c

f
a
h
g
9
Material: Steel, phosphated and coated
in black plastic
Basket guard grille for S series fans (for mounting to square wall ring with long nozzle)
Part no. Size a c d e f g h
25950-2-4039 450
74375-2-4039 450
63978-2-4039 420 / 450
AC motor EC motor
074
084
(2)
094
5.0 6.5 562.0 90.0 526.0 30.0 30.0
5.0 6.5 562.0 164.0 526.0 30.0 38.0
7.0 7.0 560.0 115.0 523.0 16.5 38.0
(2) mains-powered subject to alterations
365
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
19111-2-4039
19112-2-4039
19113-2-4039
19114-2-4039
19115-2-4039
63406-2-4039
Guard grille
f

8
7

5
8
2
,
8
m
a
x
.

8
max. g
e
d
a
Material: Steel, phosphated and coated
in black plastic
Basket guard grille for A series axial fans
Part no.
19110-2-4039
subject to alterations
Size a b c d e f g
300
350
350
400
250
250
200 3.9 260.0 229.0 6.5 4.3 39.0 6.0
3.9 300.0 271.0 6.5 4.5 38.0 6.0
3.9 300.0 271.0 6.5 4.5 53.0 6.0
3.9 360.0 327.0 6.5 4.5 35.0 6.0
4.5 422.0 375.0 6.5 4.5 72.0 6.0
4.5 422.0 380.0 6.5 4.5 54.0 6.0
4.5 470.0 428.0 9.0 4.5 67.0 8.0
09414-2-4039
09415-2-4039
19699-2-4039
69667-2-4039
19117-2-4039
fd
g
h
e
a
b
c
Material: Steel, phosphated and coated
in black plastic
Guard grille for A series axial fans
Part no.
18656-2-4039
subject to alterations
Size a b c d e f g h
315
350
400
300
250
200 3.9 4.6 4.6 245.0 58.0 195.0
3.9 4.6 4.6 290.0 58.0 247.0
3.9 4.6 4.6 360.0 58.0 300.0
4.5 6.3 4.3 375.0 58.0 327.0 3.5
4.5 6.5 4.5 422.0 58.0 387.0 6.5
4.5 6.3 4.3 500.0 58.0 467.5 7.0 14.0
366
Guard grille
a
c

e
h
g
b
Material: Steel, phosphated and coated
in black plastic
Basket guard grille for K series axial fans
Part no. Size a b c d e f g h
64539-2-4039
64378-2-4039
62229-2-4039 360
450
450
19115-2-4039 350
77709-2-4039 300
66024-2-4039 250 4.5 4.3 4.3 300.0 58.0 271.0 26.0 60.0
3.9 4.5 4.5 360.0 58.0 340.0 26.0 26.0
4.5 6.5 4.5 422.0 58.0 380.0 54.0
4.5 6.3 4.3 400.0 58.0 357.0 12.0 16.0
5.0 9.0 6.5 522.0 90.0 476.0 30.0 80.0
5.0 9.0 6.5 522.0 90.0 476.0 30.0 30.0
subject to alterations
1,5
4

1
8
2
5,8
208

1
9
1
74
Material: Steel, galvanized and blue
chromated (alternative: nickel-plated)
Guard grille for diagonal fan
Part no. Size
26388-2-4039 180
subject to alterations
367
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Guard grille
+
0
.
3
5
,
5

1
2
1
7
,
6

+
2
2
4
0

22,3
2,4

2
1
9
,
4
Material: Steel, plastic-coated
(silver-metallic gloss)
Guard grille for diagonal fan (inlet side mounting)
Part no.
35139-2-4039
subject to alterations
Size
208

2
2
5
2,4
8,8

2
4
0
+
2

2
3
1
-
1 5
,
5
+
0
.
3
Material: Steel, plastic-coated
(silver-metallic gloss)
Guard grille for diagonal fan (outlet side mounting)
Part no.
35138-2-4039
subject to alterations
Size
208
368
Guard grille
3
5
0,25
+1
167,5
0,5
6
5
,
5

0
,
2
1
3
7
1
5
2

1
A
B
1
1
,
5
6
5
5
6
2
,
5
A - B
Material: Steel, galvanized and blue
passivated
Guard grille for diagonal fan
Part no. Size
51019-2-4039 130
subject to alterations
1
6
2

1
4
2
6
2
1,5
4
,
3
1
5
9
Material: Steel, galvanized and blue
chromated (alternative: nickel-plated)
Guard grille for axial fan (according to EN 294)
Part no. Size
50952-2-4039 130 / 142 / 143
subject to alterations
369
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Guard grille

1
3
9

1
5
4

1
2

1
6
2
4.30.3 4
Material: Steel, plastic-coated
(silver-metallic gloss)
Guard grille for diagonal fan
Part no.
03749-2-4039
subject to alterations
Size
142
04013-2-4039 143

c
6,4
2,4 b

d
a
Material: Steel, plastic-coated
(silver-metallic gloss)
Guard grille for diagonal fan
Part no.
78128-2-4039
subject to alterations
Size
200
09418-2-4039 250
a b c d
240.0 5.4 221.5 208.0
295.0 6.4 278.5 270.0
370
Guard grille
09518-2-4039 250 295.0 265.0 7.0
09532-2-4039 300 380.0 323.0 9.0
6
x
6
0

c
b
a
max. 8
Material: Steel, phosphated and coated
in black plastic
Guard grilles (e.g. for axial fans)
Part no. Size
09513-2-4039 200
a b c
250.0 227.0 6.0
subject to alterations
371
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Streamers
10
a
53
103
1
0
3

c
Material: Plastic PA6, 30GV, black
(in accordance with UL 94 HB)
Streamers for axial fans
Part no.
29550-2-2955
subject to alterations
Size
315
(1) Mounting options for other axial fans respectively basket guard grilles upon request.
a b c Standard types
(1)
10.0 321.0 333.0
S4D 315-AP10 -30
S4E 315-AP18 -30
S6E 315-AP02 -30
29551-2-2955 350 10.0 361.0 373.0
S4D 350-BR06 -30
S4D 350-AR06 -30
S4E 350-BR06 -30
S4E 350-AR06 -30
S6E 350-BR08 -30
S6E 350-AR08 -30
29552-2-2955 400 10.0 401.0 413.0
S4D 400-AP12 -03
S4E 400-AP02 -03
S6E 400-AP10 -30
29553-2-2955 450 12.0 466.0 478.0
S4E 450-GA09 -01
29554-2-2955 500 13.0 496.0 508.0
S4E 500-CY09 -01
S4E 500-AY09 -01
S6E 500-CS05 -01
S6E 500-AS05 -01
S6E 500-CT05 -01
S6E 500-AT05 -01
Typical installation
s 2 4 6 8 34 32 30 28 26 24 22 20 18 16 14 12 10
[
m
/
s
]
[m]
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
v
S4E500 (5060 m
3
/h @ 180 Pa) S4E400 (3230 m
3
/h @ 45 Pa)
S4E315 (1670 m
3
/h @ 35 Pa) S4E450 (5430 m
3
/h @ 65 Pa) S4E350 (2140 m
3
/h @ 60 Pa)
Thrust ranges (measured in a typical heat exchanger) Comparison
With streamer
Without streamer
372
Wall rings

h
1
5

a
g

c
6
x
6
0

e
f
i
d
b
Material: Sheet steel, pre-galvanised and
coated in black plastic
Wall rings with long nozzle for axial fans
Part no. Size a b c d e f g h i
18900-2-4037
18892-2-4037
18902-2-4037
18908-2-4037 300
315
330
350
18930-2-4037 400
18929-2-4037 420
64000-2-4037 450
(1)
18910-2-4037 250 (A series)
64009-2-4037 250 (S series)
18912-2-4037 200 280.0 80.0 202.5 5.0 7.0 4.5 245.0 250.0 1.25
320.0 86.5 259.5 6.0 7.0 4.5 290.0 295.0 1.25
320.0 85.0 256.5 6.0 7.0 4.5 290.0 295.0 1.25
397.0 80.0 326.0 11.0 9.0 M4 360.0 380.0 1.50
397.0 74.0 347.0 11.0 9.0 M6 374.0 380.0 1.50
440.0 80.0 369.0 11.0 9.0 M6 408.0 404.0 1.50
460.0 80.0 390.0 12.0 9.0 M6 422.0 442.0 1.50
528.0 96.0 419.0 12.0 9.0 M8 500.0 504.0 1.50
544.0 96.0 447.0 12.0 9.0 M8 500.0 520.0 1.50
607.0 100.0 465.0 14.0 11.0 M8 560.0 578.0 1.50
(1) For mounting the axial fan, use guard grille 63978-2-4039 subject to alterations

a
R
1
5
1,5
d
45
c

0
,5
Material: Sheet steel, pre-galvanised
Square wall rings with short nozzle for S series axial fans
Part no. Size a b c d
35222-2-4037 350 358.0 422.0 795.0 M6
35223-2-4037 400 400.0 468.0 840.0 M8
35224-2-4037 420 426.0 500.0 850.0 M8
35225-2-4037 450 452.0 515.0 850.0 M8
subject to alterations
373
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Wall rings
1
,
5
d
g
a

c
e
f
b
h
Material: Sheet steel, pre-galvanised and
coated in black plastic
Square wall rings with long nozzle for axial fans
Part no.
18918-2-4037
subject to alterations
Size a b c d e f g h
200 312.0 52.0 203.0 6.0 7.0 4.5 245.0 260.0
37701-2-4037 250 (S series) 370.0 56.0 260.0 6.0 7.0 4.5 290.0 320.0
18933-2-4037 250 (A series) 370.0 55.0 257.0 6.0 7.0 4.5 290.0 320.0
18924-2-4037 300 430.0 80.0 326.0 11.0 9.0 4.5 360.0 380.0
18903-2-4037 315 430.0 72.5 345.0 11.0 9.0 M6 375.0 380.0
18901-2-4037 350 485.0 80.0 388.0 12.0 9.0 M6 422.0 435.0
64005-2-4037 400 540.0 98.0 417.0 12.0 9.0 M8 500.0 490.0
64006-2-4037 420
(1)
576.0 94.0 439.0 14.0 11.0 M8 560.0 535.0
64007-2-4037 450
(1)
576.0 100.0 465.0 14.0 11.0 M8 560.0 535.0
(1) For mounting the axial fan, use guard grille 63978-2-4039
64001-2-4037

c
f
b
d
4xM6
a
h
4
5

4x90
Material: Sheet steel, pre-galvanised and
coated in black plastic
Guard grilles: See p. 364
Comment: Contact us for article numbers
for complete fans.
Square wall rings with long nozzle for S series axial fans (for nozzle-side mounting)
Part no.
64020-2-4037
subject to alterations
Size a b c d e f h
450
400 540.0 98.0 409.0 12.0 9.0 10.0 490.0
576.0 100.0 463.0 14.0 11.0 10.0 535.0
Typical installation
374
Connection leads
23
1
5
a
10
7,5
7
,
5
Plug terminal: 2.8 x 0.5 mm
Connection lines for axial compact fan (with plug terminal)
Part no. Size a
01505-4-6711 142 / 143
01477-4-6711 142 / 143
01434-4-6711 142 / 143 610
1000
2000
subject to alterations
a
31,5
2
2
,
5
7
40
2
7
,
5
1
0
9,3
Design: Cable conforms to UL standards,
sealed plug
Connection lines for energy-saving motors (ESM)
Part no.
10637-4-1040
subject to alterations
a
450
10640-4-1040 600
10638-4-1040 1500
10639-4-1040 32000
Jacketed cable, internal line
(UL Style 2464/1061)
3 x AWG20 (approx. 0.5 mm
2
)
Brass lead tips
375
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Programming device
for energy-saving motors (ESM)
Description: Programming unit for setting 2 possible speeds via the USB port of a PC.
System requirements: Windows 2000 / XP
Delivery scope: Programming unit
Supply plug unit
USB connection line
Motor connecting cable
Programming software
Type of protection: IP 20
Protection class: III
Nominal data
Type
CBC 000-AC02 -02
subject to alterations
9
0
2
4
50
C C
0 to +45 -20 to +65
P
e
r
m
.
a
m
b
.
t
e
m
p
.
P
e
r
m
.
s
t
o
r
a
g
e

t
e
m
p
.
376
Connection leads
41
a
85
8
2
4
12,9
Connection lines for Q-motors (plug terminal design)
Part no. a
79574-4-6711
79573-4-6711
79572-4-6711 420
970
1470
79575-4-6711 1970
79576-4-6711 2470
79577-4-6711 2970
79578-4-6711 3470
79579-4-6711 3970
79580-4-6711 4470
62402-4-6711 4970
subject to alterations
Cable cross-section (3 x 0.75 mm
2
)
Brass lead tips
377
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Axial impellers
a
6
,
6
c
b
c
b
Material: Sheet aluminium
Axial impeller for Q-motors and energy-saving motors (ESM)
Part no. for direction of air flow "V" Part no. for direction of air flow "A"
73801-2-3634 73761-2-3634
subject to alterations
Blade angle a b c
154.0 27.5 14.0 22 130
73802-2-3634 73762-2-3634 154.0 32.0 16.0 28 130
73803-2-3634 73763-2-3634 154.0 37.0 18.0 34 130
22 130
28 130
34 130
22 130
28 130
34 130
22 130
28 130
34 130
22 130
28 130
34 130
22 130
28 130
34 130
73804-2-3634 73764-2-3634 172.0 31.0 14.5
73805-2-3634 73765-2-3634 172.0 36.0 17.0
73806-2-3634 73766-2-3634 172.0 42.0 21.0
73807-2-3634 73767-2-3634 200.0 32.0 15.5
73808-2-3634 73768-2-3634 200.0 37.5 18.0
73809-2-3634 73769-2-3634 200.0 45.0 22.0
73810-2-3634 73770-2-3634 230.0 35.0 17.5
73811-2-3634 73771-2-3634 230.0 43.0 21.5
73812-2-3634 73772-2-3634 230.0 50.0 24.0
73813-2-3634 73773-2-3634 254.0 37.0 19.0
73814-2-3634 73774-2-3634 254.0 45.0 23.5
73815-2-3634 73775-2-3634 254.0 52.0 26.0
73816-2-3634 73776-2-3634 300.0 43.0 21.5
73817-2-3634 73777-2-3634 300.0 53.5 26.5
73818-2-3634 73778-2-3634 300.0 61.0 30.0
"V" "A" U

D
i
r
e
c
t
i
o
n

o
f

r
o
t
a
t
i
o
n
4 x 4.0 with pitch circle for holes 25.4 mm
378
Guard grille for Q-motors and energy-saving motors (ESM)
Part no. a b c
50967-2-4039 170.0 190.0 11.5
(1) When used with M4Q045-EF, blade angles up to 34 are possible subject to alterations
2,7
c

a
5
b
9
4
,5
Material: Steel, galvanized and blue
chromated
Guard grille
Max. blade angle at "V"
34
Max. blade angle at "A"
34
Size
154
50968-2-4039 188.0 208.0 11.5 34 34 172
50969-2-4039 214.0 236.0 11.5 34 28 200
50970-2-4039 246.0 266.0 17.5 28 28 230
50971-2-4039 270.0 290.0 17.5 28 28 254
50972-2-4039
(1)
324.0 344.0 17.5 22 300
Basket guard grille for Q-motors and energy-saving motors (ESM)
Part no. a b c
66309-2-4039
(1) When used with M4Q045-EF, blade angles up to 34 are possible subject to alterations

b
c
94,5
5
2,7
9
2
Material: Steel, galvanized and blue
chromated
Max. blade angle at "V" Max. blade angle at "A" Size
66310-2-4039
188.0 208.0 37.5 34 34 172
66311-2-4039
212.0 236.0 37.5 34 28 200
66312-2-4039
246.0 266.0 40.0 28 28 230
270.0 290.0 40.0 28 28 254
66313-2-4039
(1)
324.0 344.0 46.8 22 300
379
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Wall rings for Q-motors and energy-saving motors (ESM), direction of air flow "V"
Part no. a b c d
52542-2-4037 164.0 190.0 200.0 24.0
(1) When used with M4Q045-EF, blade angles up to 34 are possible subject to alterations
4,3
b
6
7
4,3
c
2
48
R
3
,
5
d
6
7
1

a
Material: Sheet steel, coated in grey plastic
Wall rings
Max. blade angle
34
Size
154
52543-2-4037 182.0 208.0 223.0 24.0 34 172
52544-2-4037 210.0 236.0 246.0 24.0 34 200
52545-2-4037 240.0 266.0 276.0 24.0 28 230
52546-2-4037 264.0 290.0 300.0 24.0 28 254
52547-2-4037
(1)
308.0 344.0 356.0 24.0 22 300
Wall rings for Q-motors and energy-saving motors (ESM), direction of air flow "A"
Part no. a b c d
52550-2-4037 162.0 190.0 200.0 24.0
(1) When used with M4Q045-EF, blade angles up to 34 are possible subject to alterations
Max. blade angle
34
Size
154
52551-2-4037 180.0 208.0 223.0 24.0 34 172
52552-2-4037 208.0 236.0 246.0 24.0 28 200
52553-2-4037 238.0 266.0 276.0 24.0 28 230
52554-2-4037 262.0 290.0 300.0 24.0 28 254
52555-2-4037
(1)
308.0 344.0 356.0 24.0 22 300
4,3
b
c
6
7
6
7
4,3
36
R
4
,
5
2
d

a
1
Material: Sheet steel, coated in grey plastic
"V"
"A" U
380
Mounting bracket
Mounting bracket for Q-motors (foot measure 18 mm)
Part no. a b c d
51025-2-4053 56.0 51.0 78.0 100.0
Suitable Q-motor
M4Q045-BD01-**
M4Q045-BD01-**, M4Q045-CA01-**
M4Q045-CA01-**, M4Q045-CA03-**
M4Q045-CA03-**, M4Q045-CF01-**, M4Q045-DA01-**
M4Q045-DA01-**, M4Q045-DA05-**, M4Q045-EA01-**, M4Q045-EF01-**
subject to alterations
Material: Sheet steel, galvanized and blue
chromated
Size
172
Vers.
1
1
1
2
3
51028-2-4053 67.0 51.0 78.0 100.0 200
51026-2-4053 74.5 51.0 78.0 100.0 230
51027-2-4053 85.5 51.0 78.0 100.0 254
51014-2-4053 112.0 150.0 172.0 300
Mounting bracket for Q-motors (foot measure 26 mm)
Part no. a
71881-2-4053 39.0
Suitable Q-motor
M4Q045-BD01-**
M4Q045-BD01-**
M4Q045-BD01-**, M4Q045-CA01-**
M4Q045-CA03-**, M4Q045-CF01-**
M4Q045-DA01-**
subject to alterations
Material: Sheet steel, galvanized and blue
chromated
Size
154
Vers.
1
1
1
1
2
71882-2-4053 52.0 172
71883-2-4053
72.0 200
M4Q045-CA01-**, M4Q045-CA03-** 1 72.0 230
71884-2-4053 84.0 254
71885-2-4053 84.0 254
M4Q045-DA01-**, M4Q045-DA05-** 2 71886-2-4053 109.0 300
M4Q045-EA01-**, M4Q045-EF01-** 3 71887-2-4053 109.0 300
2
,
5
c
d
b
18
4,3 14
8
,
2
8
2
5
a
2
,
5
c
d
b
18
a
26
1
0
9

14
8
,
218
4,3
2
5
1
6
6
,
2
16,2
5
18
4,2
4
0
2
4
1
8
2
,
5
a
51
78
100
26
4,3
1
,
5
8
,
2
14
2
4
2
,
5
a
51
78
100
26
4,3
2
1
4
0
14
8
8
,
2
2
,
5
a
51
78
100
26
4,3
8
,
2
14
7
3
1
,
8
1
3
5
0
,
3
Vers. 1 Vers. 2 Vers. 3
Vers. 1 Vers. 2 Vers. 3
381
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
27,5 18
3
c
5
8
1
2

a
b 56
2
9
91,5
9
4
= =
Material: ABS
Description: Two-piece terminal box for
AC motors of size 068 or 074, terminal strip
with 4- or 7-pole.
Suitable for installation of capacitor with
10 F max.
Type of protection: IP 54
Terminal box
Part no. AC motor
64442-1-7612 068 (4 poles)
a b c
22.0 5.0 4.3
64444-1-7612 068 (7 poles) 22.0 5.0 4.3
64443-1-7612 074 (4 poles) 12x14.5 10.5 5.5
64445-1-7612 074 (7 poles) 12x14.5 10.5 5.5
subject to alterations
Mounting angles, terminal boxes
Mounting angle for energy-saving motors (ESM)
Part no. a b
63500-2-4060 103.0 152.0
subject to alterations
25
b
a
2
98
67
4,3
22x45
7
5
6
7
1
5
,
5
15,5
8
,
2
78
5x45
1
0
Material: Sheet steel, hot-galvanised
Max. blade angle at "V"
34
Max. blade angle at "A"
34
Size
154 / 172
63501-2-4060 123.0 172.0 34 28 200
63502-2-4060 135.0 184.0 28 28 230 / 254
382
Capacitors
c
M
8 a
10 b

7
1
10
Material: Housing made of thermoplastic resin
Connection line: Multi-lead
PVC cable 0.5 mm
2
with brass lead tips
Approval: VDE according to DIN EN 60252
(VDE 0560/8)
Calculated life time:
400 V; -25 to +85C; 30,000 hrs; class A
450 V; -25 to +85C; 10,000 hrs; class B
MKP motor capacitors (without fuse)
Part no. Capacity
02100-4-7320 1.0 F
a b (max.) c
25-28 58.0 235.0
99282-4-7320 1.5 F 25-28 58.0 235.0
99283-4-7320 2.0 F 25-28 58.0 235.0
02103-4-7320 2.5 F 25-28 70.0 235.0
68462-4-7320 3.0 F 25-28 70.0 235.0
99284-4-7320 4.0 F 28-32 58.0 235.0
02101-4-7320 5.0 F 30-36 70.0 235.0
99285-4-7320 6.0 F 30-36 70.0 235.0
66788-4-7320 7.0 F 30-36 72.0 100.0
99286-4-7320 8.0 F 35-40 72.0 235.0
99287-4-7320 10.0 F 35-40 72.0 200.0
66786-4-7320 12.0 F 40.0 72.0 100.0
30457-4-7320 14.0 F 40-45 92.0 150.0
50090-4-7320 16.0 F 35-40 95.0 100.0
90034-4-7320 20.0 F 40.0 95.0 235.0
90025-4-7320 25.0 F 40.0 120.0 235.0
subject to alterations
383
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Capacitors
235
7 35
M
8 a
10 b
c

a
+

3
,
5

+10
-5

+5
1
m
a
x
.

9

m
m
Material: Plastic cap, aluminium cup
Designation: FPU or P2 according to
IEC 252 (non-flammable, non-explosive,
circuit-breaking)
Approval: VDE according to DIN EN 60252
(VDE 0560/8)
Calculated life time:
420 V; -25 to +85C; 30,000 hrs; class A
470 V; -25 to +85C; 10,000 hrs; class B
500 V; -25 to +85C; 3,000 hrs; class C
Pull-off protector: The housing expands
by max. 9 mm. The protector responds to
overload by the generated excess pressure
snapping off the internal lead in a predeter-
mined breaking point.
Mounting: c is the overall dimension of the
capacitor which has to be taken into account
when mounting the part. The capacitor
design, however, depends on the manufac-
turer. The expansion (9 mm) is either added
to dimension b, or it is already integrated in
the capacitor.
MKP motor capacitors FPU or P2 (with fuse)
Part no.
02151-4-7320
a b (max.) c (max.)
subject to alterations
Capacity
1.0 F 25-30 77.0 92.0
02155-4-7320 25.0 77.0 92.0
02156-4-7320 25.0 77.0 92.0
02159-4-7320 30.0 71.0 92.0
02160-4-7320 30.0 71.0 92.0
02161-4-7320 25-30 104.0 135.0
02162-4-7320 25-30 104.0 113.0
02163-4-7320 30.0 101.0 110.0
02164-4-7320 30-35 101.0 110.0
02165-4-7320 30-35 102.0 111.0
02166-4-7320 35.0 96.0 110.0
02167-4-7320 35.0 96.0 110.0
90026-4-7320 40.0 130.0 139.0
02168-4-7320 40.0 96.0 130.0
02169-4-7320 40.0 116.0 130.0
02170-4-7320 40-45 116.0 130.0
1.5 F
2.0 F
2.5 F
3.0 F
4.0 F
5.0 F
6.0 F
7.0 F
8.0 F
10.0 F
12.0 F
14.0 F
16.0 F
20.0 F
25.0 F
384
TCD 070-AA01 -05 3~ 400 50/60 7.0 19.7
Speed setting device, 3-phase (with 5 steps)
for wall assembly
Technical features: Input for TOP
Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC
Type of protection: IP 20 (with vertical installation)
Nominal data
Type
TCD 020-AA01 -05
TCD 040-AA01 -05
subject to alterations
1
8
9
309
304
2
2
4
1
6
6
1
8
9
4
x

5
,
5
1
8
5
266
VAC Hz A kg
3~ 400 50/60 2.0 9.5
3~ 400 50/60 4.0 13.9
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
C
u
r
r
e
n
t

d
r
a
w
M
a
s
s
385
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Speed setting device, single-phase (with 5 steps)
for wall assembly
Technical features: Input for TOP
Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC
Type of protection: IP 40
Nominal data
Type
TCE 021-AA01 -05
TCE 040-AA01 -05
subject to alterations
204
1
5
4
200
4
x

7
1
6
7
1
4
7
8
6
144
VAC Hz A kg
1~ 230 50/60 2.1 3.6
1~ 230 50/60 4.0 4.8
TCE 075-AA01 -05 1~ 230 50/60 7.5 6.5
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
C
u
r
r
e
n
t

d
r
a
w
M
a
s
s
386
Motor protection switch, 3-phase
for assembly inside a cabinet
Technical features: Input for TOP
Electr. connection:
Nominal data
Type
TPD 250-AB01 -01
TPD 250-AB01 -02
subject to alterations
VAC Hz A kg
3~ 400 50/60 25.0 0.3
Auxiliary contactor
Without auxiliary contactor
With break contact 3~ 400 50/60 25.0 0.3
TPD 250-AB01 -03 With make contact 3~ 400 50/60 25.0 0.3
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
C
u
r
r
e
n
t

d
r
a
w
M
a
s
s
6
8
54,5 7
66,5
387
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Motor protection switch, single-phase
for assembly inside a cabinet
Technical features: Input for TOP
Electr. connection:
Nominal data
Type
TPE 100-AB01 -01
TPE 100-AB01 -02
subject to alterations
VAC Hz A kg
3~ 230 50/60 10.0 0.3
Auxiliary contactor
Without auxiliary contactor
With break contact 3~ 230 50/60 10.0 0.3
TPE 100-AB01 -03 With make contact 3~ 230 50/60 10.0 0.3
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
C
u
r
r
e
n
t

d
r
a
w
M
a
s
s
1
0
3
52,5
4
6
4
5
70
78
388
Motor-protection switch, single phase and three-phase
for wall assembly
Technical features: Input for TOP
Type of protection: IP 55
Electr. connection, three-phase:
Electr. connection, single-phase:
Nominal data
Type
TPD 250-AA01 -01
TPD 250-AA01 -02
subject to alterations
VAC Hz A kg
3~ 400 50/60 25.0 0.6
Auxiliary contactor
Without auxiliary contactor
With break contact 3~ 400 50/60 25.0 0.6
TPD 250-AA01 -03 With make contact 3~ 400 50/60 25.0 0.6
TPE 100-AA01 -01 Without auxiliary contactor 1~ 230 50/60 10.0 0.6
TPE 100-AA01 -02 With break contact 1~ 230 50/60 10.0 0.6
TPE 100-AA01 -03 With make contact 1~ 230 50/60 10.0 0.6
N
o
m
i
n
a
l

v
o
l
t
a
g
e
F
r
e
q
u
e
n
c
y
C
u
r
r
e
n
t

d
r
a
w
M
a
s
s
1
4
1
79
38
80
92
20
389
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Star-delta switch / repair switch
Third-party accessories from Mller Electric GmbH
For more information: www.moeller.net
Star-delta switch (available from Mller Electric GmbH)
Designation
T0-4-8410/I1
Installation
Wall installation
T0-4-8410/E Cabinet installation
subject to alterations
For more information: www.moeller.net
Repair switch, lockable (available from Mller Electric GmbH)
Designation
T0-2-8900/I1/SVB-SW
Installation
Wall installation
T0-2-8900/EA/SVB-SW Cabinet installation
subject to alterations
for wall installation
for wall installation
390
391
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Technology
Control technology 414
Motors 410
Impellers 396
Technical parameters & scope 392
392
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
General performance parameters
Any deviations from the technical data and parameters described here
are listed on the product-specific data sheet.
Type of protection
The type of protection is specified in the product-specific data sheets.
Insulation class
The insulation class is specified in the product-specific data sheets.
Mounting position
The mounting position is specified in the product-specific data sheets.
Condensate discharge holes
Information on the condensate discharge holes is provided in the
product-specific data sheets.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Protection class
The protection class is specified in the product-specific data sheets.
Service life
The service life of ebm-papst products depends on two major factors:
The service life of the insulation system
The service life of the bearing system
The service life of the insulation system mainly depends on voltage level,
temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
on the bearing.
The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
used, which is indicated on the product-specific data sheet wherever
applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
operating hours at an ambient temperature of 40 C, yet this estimate
can vary according to the actual ambient conditions.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
product-specific data sheets.
Depending on motor type and field of application, the following protective
features are realised:
Thermal overload protection (TOP), either in-circuit or external
PTC with electronic diagnostics
Impedance protection
Thermal overload protection (TOP) with electronic diagnostics
Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
All fans with 1~ AC voltage are equipped with a TOP that is connected
in the winding circuit.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.
393
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Legal and normative directives
The products described in this catalogue are designed, developed and
produced in keeping with the standards in place for the relevant product
and, if known, the conditions governing the relevant fields of application.
Standards
Information on standards is provided in the product-specific data sheets.
EMC
Information on EMC standards is provided in the product-specific data
sheets.
Complying with the EMC standards has to be established on the final
appliance, as different mounting situations can result in changed EMC
properties.
Leakage current
Information on the leakage current is provided in the product-specific
data sheets.
The measurement takes place according to Fig. D.1 according to
IEC 60990, Fig. 4.
Approvals
In case you require a specific approval for your ebm-papst product
(VDE, UL, GOST, CCC, CSA, etc.) please let us know.
Most of our products can be supplied with the relevant approval.
Information on existing approvals is provided in the product-specific
data sheets.
Air performance measurements
All air performance measurements are carried out on inlet-side chamber
test rigs in conformity with the requirements of DIN 24163 and ISO 5801.
The fans being tested are installed on the measuring chamber at free air
intake and discharge (installation type A according to DIN 24163 Part 1)
and are operated at nominal voltage (for AC, also at nominal frequency)
without additional attachments such as the guard grille.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m
3
.
Left: Endurance test room
Middle: Shock test
Right: Chamber test rig
Mechanical strain / performance parameters
All ebm-papst products are subjected to comprehensive tests complying
with the normative specifications. In addition to this, the tests also reflect
the vast experience and expertise of ebm-papst.
Vibration test
Vibration tests are carried out in compliance with
Vibration test in operation according to DIN IEC 68, parts 2-4
Vibration test at standstill according to DIN IEC 68, parts 2-4
Shock load
Shock load tests are carried out in compliance with
Shock load according to DIN IEC 68, parts 2-27
Balancing quality
Testing the balancing quality is carried out in compliance with
Residual imbalance according to DIN ISO 1940
Standard balancing quality level G 6.3
Should you require a higher balancing quality level for your specific
application, please let us know and specify this when ordering your
product.
Chemo-physical strain / performance parameters
Should you have questions about chemo-physical strain, please direct
them to your ebm-papst contact.
Fields of application, industries and applications
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room
technology, automotive and rail technology, medical and laboratory tech-
nology, electronics, computer and office technology, telecommunications,
household appliances, heating, machines and plants, drive engineering.
Our products are not designed for use in the aviation and aerospace
industry!
394
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
Axial and centrifugal fans with direction of air flow "V", without guard
grille and in the wall ring
Backward curved centrifugal fans, free-running and with inlet nozzle
Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All noise levels are measured in conformity to DIN 45635 and
ISO 3744/3745 according to precision class 2 and specified A-weighted.
When the sound pressure level (L
p
) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (L
w
), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
(see graphic). The sound level measured can be roughly calculated
from the sound pressure level by adding 7 dB.
Measurement configuration according to DIN 45635 T38:
10 measuring points
d D
h = 1.5d to 4.5d
Measurement area S = 6d
2
+ 7d (h + 1.5d)
3
d
2d
h
D
1
,
5
d
Room for precision noise measuring
395
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Adding multiple noise sources with the same level
Adding 2 noise sources with the same volume results in a level increase
of approx. 3 dB. The noise characteristics of multiple identical fans can
be determined in advance based on the noise values specified in the data
sheet. This is shown in the diagram opposite.
Example: 8 A3G800 axial fans are on a condenser. According to the data
sheet, the sound pressure level of a fan is approximately 75 dB(A).
The level increase measured from the diagram is 9 dB. Thus the overall
sound level of the installation can be expected to be 84 dB(A).
Adding two noise sources with different levels
The acoustic performance of two different fans can be predetermined
based on the sound levels given in the data sheet. This is shown in the
diagram opposite.
Example: There is an axial fan A3G800 with a sound pressure level of
75 dB(A) at the operating point and an axial fan A3G710 with 71 dB(A) in
a ventilation unit. The level difference is 4 dB. The level increase can now
be read in the diagram as approx. 1.5 dB. This means that the overall
sound level of the unit can be expected to be 76.5 dB(A).
Inverse square laws
The sound level is independent of the distance from the noise source.
Conversely, the sound pressure level decreases as distance from the
noise source increases. The diagram to the right shows the level decrease
expressed in terms of an output measurement at a distance of 1 m from
the noise source under far-field conditions.
Example: An axial fan A3G800 has a sound pressure level of 75 db(A) at
the operating point. Now, you want to measure the noise characteristics at
a distance of 20 m. In the diagram to the right, you can now read a
reduction of 26 dB for the 20 m distance.
1
5
10 15 20 25 5 8 2
1
0
5
9
0
1
[
d
B
]
Number of sources of sound with identical level
I
n
c
r
e
a
s
e

i
n

s
o
u
n
d

p
r
e
s
s
u
r
e

/

s
o
u
n
d

p
o
w
e
r

l
e
v
e
l
3
12 16 20 24 8 4
2
1
1
,
5
0
0
[dB]
[
d
B
]
Difference in level with two sources of sound
I
n
c
r
e
a
s
e

i
n

s
o
u
n
d

p
r
e
s
s
u
r
e

/

s
o
u
n
d

p
o
w
e
r

l
e
v
e
l
0
10 20 50 100 5 2
-
1
0
-
2
6
-
2
0
-
3
0
-
4
0
1
[m]
[
d
B
]
Distance
D
e
c
r
e
a
s
e

i
n

s
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
Curves
396
ebm-papst construction designs
Depending on the geometrical shape of the impeller, there are different
construction designs, with their names taken from the main flow
direction in the impeller.
The most important designs are:
Axial fans
Centrifugal fans with backward curved blades
Single or dual inlet centrifugal blowers with forward curved blades
Diagonal (mixed flow) fans (a cross between axial and centrifugal fans)
Relevant fields of application of the various construction designs
The different ebm-papst fan and blower designs correspond to the
different fields of application:
Small back pressures: Axial fans
High back pressures: Centrifugal fans with backward curved blades
and single or dual inlet centrifugal blowers
Threshold between axial and centrifugal fans: Diagonal fans
Impellers
Impellers made by ebm-papst
Like pumps and compressors, fans and blowers belong to the category of aerodynamic and fluid work machines.
A fan consists of an impeller, a drive motor and a housing for suspension and for guiding the air flow. The blades spaced
along the circumference of the impeller are designed in such a way as to cause the flowing work medium to change
direction, thus passing on pressure and speed energy.
Application-specific selection parameters
When selecting an application-specific fan or blower, the main parameters
to be taken into account are these:
Air flow at given back pressure
Constructional design
Speed/rpm
Impeller diameter
Ambient conditions governing suction and exhaust side
Characteristic curves of the various designs
axial fans
centrifugal fans, backward curved
centrifugal blowers, single inlet
centrifugal blowers, dual inlet
diagonal fans
[m/h]
[
P
a
]
1000 200 500 2000 5000 10000 20000 50000
200
400
600
800
1000
1200
397
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Direction of air flow
The direction of air flow is given as follows:
Direction of air flow "V" Direction of air flow "A"
Operating range
To the right of the "saddle" (right part of the air performance curve):
Maximum efficiency
Minimal noise
To the left of the "saddle" (left part of the air performance curve):
Stall area
Drop in efficiency
Soaring noise
The optimum operating range of the fan is shaded in green in the
curve given here.
"V" "A" U
Axial fans
stall area optimum operating range
0
0
[m/h]
[
P
a
]
[
%
]
[
d
B
(
A
)
]
Noise / efficiency curve
398
Effects when mounted in wall ring or in the aperture
Mounting the fan in a wall ring can significantly increase the air
performance in the operating range.
Wall ring Aperture 2 1
2 1
0
0
[m/h]
[
P
a
]
1
2
[
%
]
3 2
1
0
0
[m/h]
[
P
a
]
[
%
]
1 3
2
Curve
Effects with axial position in the wall ring
Axial position in the wall ring influences air performance and efficiency.
Projecting on Flush on Immersed on
inlet side inlet side inlet side
x / D = 7 % x / D = 0 % x / D = -7 %
3 2 1
Curve
x
D
x
D
x
D
399
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Effects with guard grilles
Mounting a guard grille reduces the air performance of the axial fan.
Without guard grille
With guard grille 2
1
2 1
0
0
[m/h]
[
P
a
]
[
%
]
2
1
Curve
The pressure drop in Pa can be roughly calculated according to the
following equation:
p
GG
=
GG
.
10
-8
.
V
2
V in [m
3
/h]
For the guard grilles used at ebm-papst, the correction factor
GG
can be
used depending on the impeller diameter D from the table to the right.
Diameter D Correction factor
130
143
180
200
250
300
315
350
400
450
500
560
630
710
800
910
990
10000
6600
2550
1650
650
300
240
150
90
55
35
20
11
6
3
1.5
0.9

GG
400
Effects of obstructions on the suction or exhaust side
Disturbances or obstructions on the suction or pressure side reduce
the air performance of the axial fan.
Obstructions on the inlet side
x / D =
x / D = 35 %
x / D = 18 %
x / D = 9 %
x / D = 5 %
Obstructions on the exhaust side
x / D =
x / D = 35 %
x / D = 18 %
x / D = 9 %
x / D = 5 % 5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
0
0
[m/h]
[
P
a
]
1 3
2
4 5
0
0
[m/h]
[
P
a
]
Curve
X
D
X
D
401
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Centrifugal fans with backward curved blades
Operating range
Middle part of air performance curve:
Maximum efficiency
Minimal noise
To the right and the left of the middle part of the air performance curve:
Reduced efficiency
Increasing noise
The optimum operating range of the fan is shaded in green in the curve
given here.
optimum operating range
0
0
[m/h]
[
P
a
]
[
%
]
[
d
B
(
A
)
]
Noise / efficiency curve
Effects of nozzle gap dimension
The centrifugal air gap between the inlet nozzle and impeller cover plate
influences the air performance and efficiency of the centrifugal fan.
s / D = 0.4 %
s / D = 1.0 %
s / D = 1.4 % 3
2
1
0
0
[m/h]
[
P
a
]
[
%
]
3 1 2
3 1 2
Curve
S
D
402
Effects of overlapping dimension
The axial overlap between the inlet nozzle and impeller cover plate
influences the air performance and efficiency of a centrifugal fan.
x / D = 0.6 %
x / D = 0 %
x / D = -0.8 % 3
2
1
0
0
[m/h]
[
P
a
]
[
%
]
1
2
1
2
3
3
Curve
Effects of installation space
When mounting our product in a rectangular box, air performance
might be reduced.
d
h
= Hydraulic diameter
Formula: d
h
= 2 x B x H / (B + H)
B = Width of box
H = Height of box
D = Outer diameter of the fan
1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8
Hydraulic diameter d
h
/D
C
o
r
r
e
c
t
i
o
n

f
a
c
t
o
r

f
o
r

a
i
r

f
l
o
w
1
,
0
0
0
,
9
9
0
,
9
8
0
,
9
7
0
,
9
6
0
,
9
5
0
,
9
4
0
,
9
3
0
,
9
2
Curve
X
D
0,5
xD
DD
H
B
403
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Air flow measurement for inlet nozzles
with pressure-measuring point
The differential pressure approach compares the static pressure before
the inlet nozzle with the static pressure inside the inlet nozzle.
Air flow can be calculated on the basis of the differential pressure
(difference in pressure of the static pressures) in keeping with the
following equation:
V = k
.
p
W
V in [m
3
/h] and p
W
in [Pa]
If constant air flow control is used, then the nozzle pressure has to be
kept constant: p
W
= V
2
: k
2
k takes into account the specific nozzle characteristics.
One or four pressure measuring points are spaced along the
circumference of the inlet nozzle. Connection on the customer side
is accomplished via a premounted T tube connector. This tube connector
is suited for pneumatic hoses with an internal diameter of 4 mm.
0,5
xD
D
404
Single and dual inlet centrifugal blowers
with forward curved blades
Operating range
Middle part of air performance curve:
Maximum efficiency
Minimal noise
Higher performance density than with the backward curved
centrifugal fan
To the right and the left of the middle part of the air performance curve:
Reduced efficiency
Increasing noise
The optimum operating range of the fan is shaded in green in the curve
given here.
The forward curved centrifugal impeller must always be operated inside
a scroll housing.
A dual inlet centrifugal blower shows the same behaviour as two single
inlet blowers operated in parallel: with size, speed and pressure being
identical, double the air flow is achieved.
0
0
optimum operating range
[m/h]
[
P
a
]
[
%
]
[
d
B
(
A
)
]
Noise / efficiency curve
Dimensioning of the scroll
The dimensions of a typical scroll can be calculated with the following
formulae, subject to the impeller diameter D:
A = 1.062 D
B = 0.992 D
C = 0.922 D
D = 0.853 D
E = 0.784 D
F = 0.715 D
G = 0.646 D
H = 0.612 D
J = 0.720 D
K = 0.689 D
R = 0.073 D
Adjusting the dimensions to diminished mounting spaces is possible.
J
4
5

4
5

D
C
B
4
5

F
E
45 4
5

H
45
2
6

A
G
R
K
405
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Effects of step diffusers
A diffuser mounted on the exhaust side with connected exhaust tunnel
increases air performance and efficiency of the centrifugal blower.
without step diffuser with step diffuser 2 1
0
0
[m/h]
[
P
a
]
[
%
]
1
2
2 1
Curve
Effects of obstructions on the intake side
Obstructions on the air intake side reduce the air performance of the
centrifugal blower.
x / D =
x / D = 30 %
x / D = 23 %
x / D = 15 %
x / D = 7.5 % 5
4
3
2
1
0
0
[m/h]
[
P
a
]
1 2 3 4 5
Curve
X X
D
406
Effects caused by obstructions on the inlet side for constant air flow
EC centrifugal blowers
Constant air flow is attained with unimpaired inflow only.
An obstructed (e. g. asymmetrical or partially blocked) air flow can have a
significant effect on the curve behaviour and cause large deviations from
a constant air flow curve.
Examples of obstructed inflows
Instructions for designing a sufficiently unobstructed inflow:
The distance x between the blower intake and neighbouring walls or
obstructions should be at least 25 % of the impeller diameter.
Inflows with angular momentum or asymmetrical rotation should be
avoided.
The inflow can be made more uniform using resistances such as those
from filters or grilles.
On request, we offer calibrated blower designs that incorporate a specific
installation situation.
X
407
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Diagonal fans (axial design)
Mounting information
The conical housing (part of delivery) makes sure the necessary gap
dimension is kept.
Effects
The effects of the diagonal/mixed flow fan are similar to those listed
for the axial fan (p. 397-400).
Operating range
Directly to the right of the "saddle" (right part of the air
performance curve):
Maximum efficiency
Minimal noise
To the left of the "saddle" (left part of the air performance curve):
Stall area
Drop in efficiency
Soaring noise
The saddle of the diagonal/mixed flow fan is slightly higher than that
of the axial fan. This means that the technical ratings in the optimal
operating range are better than those of the axial fan.
The optimum operating range of the fan is shaded in green in the
curve given here.
stall area optimum operating range
0
0
[m/h]
[
P
a
]
[
%
]
[
d
B
(
A
)
]
Noise / efficiency curve
408
Dimensioning / change in speed
Influence of speed n
A change in speed influences:
Air flow V
V ~ n
Static pressure increase p
fa
p
fa
~ n
2
Requirement of energy P
1
P
1
~ n
3
140
1
6
0
100 80 60 40 20 120
1
0
0
1
2
0
1
4
0
8
0
6
0
4
0
2
0
0
0
[%]
[
%
]
n
0.9n
0.8n
0.7n
0.6n
1.1n
1.2n
1.3n
1.4n
Curve
Influence of the speed n on the sound level Lw
When the speed changes, the approximate sound level can be
determined using the diagram to the right and the following formula:
Lw
2
- Lw
1
= 50 dB
.
log (n
2
: n
1
)
Lw
1
= Sound level after speed change
Lw
2
= Sound level before speed change
n
1
= Changed speed
n
2
= Starting speed
2 2,5 3 1,5 1
0
-
1
0
-
2
0
1
0
2
0
0,5
[
d
B
]
factor of speed change
m
o
d
i
f
i
c
a
t
i
o
n

i
n

s
o
u
n
d

p
r
e
s
s
u
r
e

l
e
v
e
l
Curve
409
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Influence of impeller diameter D
A change in impeller diameter influences:
Air flow V
V ~ D
3
Static pressure increase p
fa
p
fa
~ D
2
Requirement of energy P
1
P
1
~ D
5
Influence of width of air discharge b (only for centrifugal impellers)
A change in width of the air discharge influences, in approximation:
Air flow V
V ~ b
Static pressure increase p
fa
p
fa
= const
Requirement of energy P
1
P
1
~ b
140
1
6
0
100 80 60 40 20 120
1
0
0
1
2
0
1
4
0
8
0
6
0
4
0
2
0
0
0
[%]
[
%
]
D
0.9D
0.8D
0.7D
0.6D
1.1D
1.2D
1.3D
140
1
6
0
100 80 60 40 20 120
1
0
0
1
2
0
1
4
0
8
0
6
0
4
0
2
0
0
0
[%]
[
%
]
b 0.8b 0.6b 1.2b 1.4b
0.9b 0.7b 1.1b 1.3b
Curve
Curve
410
Motors
Motors made by ebm-papst
In AC and EC technology, ebm-papst relies on the proven external-rotor motor principle, with the rotor turning
around the stator within. Advantages of the ebm-papst external-rotor principle are:
Space saving design due to integrated bearings and direct installation inside the impeller
Lower load and more precise balancing of the bearing due to the fixed connection of all rotating elements
Prolonged service life due to the motor-impeller unit placed right within the air flow
The ebm-papst motors achieve very good results in efficiency and acoustic behaviour when used in EC technology.
1 ~ AC voltage
connector
3 ~ AC voltage
connector
DC voltage
connector
Design of
circuit diagram
- Stator -
AC motors EC motors Features
Limited use
(Steinmetz circuit)
Yes
No
No
No
No
No
No
Yes
Yes
Yes Yes Yes Yes
Yes
Rotor principle
Efficiency
Squirrel cage
Good Low Medium Excellent Excellent
Squirrel cage Squirrel cage Magnetic rotor Magnetic rotor
Noise behaviour Excellent Medium Good Medium Excellent
Continuous speed
setting integrated
No No No Yes Yes
3-phase motor Shaded-pole motor Single-phase
capacitor motor
Single-core motor 3-core motor
Steinmetz circuit
Electronics
(see p. 418)
Electronics
(see p. 418)
411
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
AC motors
AC motors (induction motors) are based in their function on the principle
of the asynchronous rotation of the stator rotating field and rotor.
Start-up current
The start-up current of our AC motors is maximally 4x higher than the
nominal current given.
[
N
c
m
]
4
2
1
5
3
M
St
M
Sa
M
K
Torque curves of the motor types
Key:
1 - EC motor
2 - 3-phase motor
3 - Single-phase motor
4 - Shaded-pole motor
5 - System characteristic
M
St
- Starting torque
M
Sa
- Saddle torque
M
K
- Breakdown torque
Shaded-pole motor
Each pole of the motor is divided electro-magnetically into a main
and auxiliary pole (split) via a cage winding in order to generate a
starting torque.
At ebm-papst, shaded-pole motors are available as 2 or 4-pole
symmetrical external or internal rotor designs.
Advantages:
Extremely robust motor design due to cast squirrel cage rotor
and stable bearing system
Cost-efficient motor
Extremely easy to connect
Long service life
412
Single-phase capacitor motor
Two cores (main winding MW and auxiliary winding AW) generate
the rotating field of the single-phase capacitor motor via a capacitor
connected in series to form an auxiliary winding.
Advantages:
Extremely robust motor design due to cast squirrel cage rotor
and stable bearing system
Diverse options for setting speed
Efficiency between 30 % and 75 % (depending on motor size)
Long service life
Good vibration and noise behaviour
3-phase motor
The three motor cores are offset by 120 and generate a circular rotating
field when connected to the 3-phase mains.
Advantages:
Extremely robust motor design due to cast squirrel cage rotor
and stable bearing system
Very good vibration and noise behaviour
Efficiency between 40 % and 80 % (depending on the motor size)
Long service life
Delta Star Steinmetz circuit
1
2
3
[
N
c
m
]
Torque curves of 3-phase motors
c 70F/ kW
(230 VAC )
Key:
1 - Delta
2 - Star
3 - Steinmetz circuit
413
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
EC motors
Single-core motor
Advantages:
Integrated speed setting
Efficiency between 50 % and 80 % (depending on the motor size)
Long service life
3-core motor
Advantages:
Integrated speed setting
Good efficiency between 60 % and 90 %
(depending on the motor size)
Long service life
Very good vibration and noise behaviour even in
controlled operation
Can be used as drive motor
4
2 [
N
c
m
]
1
5
3
M
St
M
Sa
M
K
Torque curves of the motor types
Key:
1 - EC motor
2 - 3-phase motor
3 - Single-phase motor
4 - Shaded-pole motor
5 - System characteristic
M
St
- Starting torque
M
Sa
- Saddle torque
M
K
- Breakdown torque
EC motors are based in their function on the principle of the
synchronous rotation of stator rotating field and rotor.
Electronics
Electronics
414
Control technology
Open and closed loop control using ebm-papst technology
Depending on the field of application, fan speed has to be adjusted. In AC technology, the speed setting option can
result in an increase in installation expenditure and, typically, a less favourable noise performance and an increase in
power input.
Here, ebm-papst EC technology is a more eco-friendly and cost-efficient alternative. The EC motor with integrated
commutation electronics offers high efficiency across the entire speed range and optimal acoustic performance
at minimal installation expenditure.
Installation ++ + +
AC EC commutating electronics Features
+ + ++ + ++ +
+ + ++ +
+ + + + + + +
Power input
Service life
Noise behaviour
S
e
r
i
e
s

r
e
s
i
s
t
a
n
c
e
T
r
a
n
s
f
o
r
m
e
r
S
p
e
e
d

s
t
e
p
p
i
n
g

P
h
a
s
e
-
a
n
g
l
e

c
o
n
t
r
o
l
P
h
a
s
e
-
a
n
g
l
e

c
o
n
t
r
o
l
w
i
t
h

s
i
n
e

f
i
l
t
e
r

F
r
e
q
u
e
n
c
y

i
n
v
e
r
t
e
r
F
r
e
q
u
e
n
c
y

i
n
v
e
r
t
e
r
w
i
t
h

s
i
n
e

f
i
l
t
e
r
I
n
t
e
g
r
a
t
e
d
I
n
t
e
g
r
a
t
e
d

w
i
t
h
s
w
i
t
c
h

p
o
w
e
r
s
u
p
p
l
y
E
x
t
e
r
n
a
l
30
2000
1000
4000 6000 8000 10000
2000 3000 4000 5000 6000
40
50
60
70
[m/h]
[CFM] 0
[
d
B
A
]
2000
1000
4000 6000 8000 10000
2000 3000 4000 5000 6000
500
1000
1500
[m/h]
[CFM] 0
[
W
]
Acoustic performance of controlled motors Power input of controlled motors
Key:
ebm-papst EC controls
Frequency inverter with sine filter
Phase-angle control without sine filter
Phase-angle control with sine filter
Transformer
Key:
ebm-papst EC controls
Frequency inverter with sine filter
Phase-angle control without sine filter
Phase-angle control with sine filter
Transformer
+ = positive ++ = very positive = negative = very negative
415
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Speed setting with AC motors
Speed setting helps to optimise power input
and the flow noise as requested.
Series resistance
Fixed speed steps
Speed setting via change in motor voltage
Cost-efficient
Small capacities
Note: Capacitors or chokes reduce the loss capacity.
0
1
2
3
L1
N
PE
R1
R2
C
AW
MW
ASM
1~
2
L1
N
PE
C
AW
MW
ASM
1~
Tr
1
3
4
L1
N
PE
C
AW
MW
ASM
1~
Tr
L1
L3
L2
PE
T2 T4 T6
T1 T3 T5
U
V
W
U
W V
+
ASM
3~
Transformer
Fixed speed steps
Speed setting via change in motor voltage
Phase-angle control
Continuous speed setting
Speed setting via change in motor voltage
Cost-efficient
Acoustic performance and warming has to be reviewed
in the application
Frequency inverter with sine filter
Continuous speed setting
Speed setting via change in frequency of rotating field
High efficiency
Note: An all-pole sine filter (phase-phase and phase-earth)
has to be used.
When selecting a voltage controller, note that the nominal current in the
partial load range can be up to 20 % (depending on the controller) above
the specified maximum current.
416
Electrical connections AC
Fans, 1 speed (3~ 230 VAC power line)
C1) Delta connection (3~ 230 VAC power system)
without TOP
L3 L2 L1
W2 2 V 2 U
1 U 1 V 1 W
PE
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
D1) Delta connection (3~ 230 VAC power line)
with TOP
A2a) Single-phase capacitor motor
with connection for external TOP
L3 L2 L1
W2 2 V 2 U
1 U 1 V 1 W
PE TOP
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
Direction of rotation is reversed by swapping
two line phases.
Fans (1~ 230 VAC power line)
A1) Single-phase capacitor motor
with TOP wired internally
C
N PE L
TOP
2 1
Z U U
U
1
= blue
U
2
= black
Z = brown
= green/
yellow
B) Shaded pole motor
with TOP wired internally
N PE L
TOP
L = blue
N = brown
= green/
yellow
C
N PE L
2 1
Z U U
TOP
U
1
= blue
U
2
= black
Z = brown
= green/
yellow
A2b) Single-phase capacitor motor
with connection for external TOP
U1 U2 Z TOP TOP
PE N L
C
U
1
= blue
U
2
= black
Z = brown
= green/
yellow
Fans
with terminal box
417
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
L3 L2 L1
W2 2 V 2 U
1 U 1 V 1 W
PE
L3 L2 L1
W2 2 V 2 U
1 U 1 V 1 W
PE TOP
L3 L2 L1
1
2
V1 U1
2 V 2 U W
W
PE
L3 TOP L2 L1
1
2
V1 U1
2 V 2 U W
W
PE
Fans, 1 speed (3~ 400 VAC power line)
C2) Star connection (3~ 400 VAC power system)
without TOP
L3 L2 L1
1
2
V1 U1
2 V 2 U W
W
PE
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
D2) Star connection (3~ 400 VAC power line)
with TOP
L3 TOP L2 L1
1
2
V1 U1
2 V 2 U W
W
PE
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
Direction of rotation is reversed by swapping
two line phases.
Fans, 2 speeds via /Y-switch (3~ 400 VAC power line)
E2) Star connection (low speed)
without TOP
E1) Delta connection (high speed)
without TOP
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
F2a) Star connection (low speed)
with TOP
F1a) Delta connection (high speed)
with TOP
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
F2b) Star connection (low speed)
with TOP
F1b) Delta connection (high speed)
with TOP
U1 V1 W1 W2 U2 V2 TOP TOP
L1 L2 L3 PE
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
PE L3 L2 L1
TOP TOP V2 U2 W2 W1 V1 U1
U
1
= black
U
2
= green
V
1
= blue
V
2
= white
W
1
= brown
W
2
= yellow
= green/
yellow
Direction of rotation is reversed by swapping two line phases.
Fans
with terminal box
Fans
with terminal box
418
The speed of EC motors is set via commutation electronics. Via electronic
circuits and depending on the rotor position, this commutation switches
the motor currents on and off.
Principle of AC-fed commutation electronics
(with electrically isolated interface)
Integrated commutation electronics
Compact unit
Easy to install
Low installation expenditure
Can be operated all over the world
Note: Motors with 12-72 VDC supply voltage have to be fed via
electrically isolated supply unit.
Integrated commutation electronics with switch power supply
Protective extra-low voltage 24 / 48 VDC
Note: Switch power supply is not included but has to be ordered
as accessory.
AC
DC
AC
DC
Principle of DC-fed commutation electronics
Speed setting with EC motors
Drive
Commutations unit
DC/DC transformer
Control unit Power unit Interface
EMC filter
Rectifier
Link electrolytic capacitor
Inverter stage
Feedback
0-10 VDC
PWM
CAN
LON
RS485
Drive
Commutations unit
Control unit Power unit Interface
EMC filter
Inverter stage
Feedback
0-10 VDC
PWM
CAN
LON
RS485
419
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Typical features of the ebm-papst commutation electronics:
Input for analogue and digital signals
Open and closed loop control as well as monitoring of the motor
Integrated EMC filter
High efficiency throughout the entire speed range
Speed setting via linear set value (0-10 VDC) or PWM signal
Low-noise operation across the entire speed range
Minimal extra costs for additional functions
(open/closed loop control)
Optional BUS interface
Types of alarms and reactions with EC motors
With DC-fed EC motors, certain faults in modes of operation are
recognised by the electronics, and the motor is automatically restarted.
With AC-fed EC motors, certain faults in modes of operation are
recognised by the electronics, and the motor is switched off.
The motor restarts automatically after the following failures have been
diagnosed:
Line failure
Phase failure
Line under-voltage
DC link voltage too high or too low
Locked rotor
With the following types of failures, there is no automatic restart.
Here, hardware or software reset is required:
Motor temperature too high
Temperature of cooling element or ambient temperature of
electronics too high
Hall failure
Hardware reset
Switching off the fan and restarting it after one minute results in
hardware reset.
Software reset
Software reset is via ebmBUS and LISA software, hand-held control
terminal, or PDA with Fan Control Software.
420
Electrical connections EC
+
0
-
1
0

V
P
W
M
T
a
c
h
G
N
D
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 1 + red Maximum ripple 3.5 % Tach white
0-10 V / PWM yellow Control input (Impedance 100 k)
GND blue GND
Line 1
red yellow white blue
Tach output:
2 pulses / revolution (M1G045/ M1G055)
3 pulses / revolution (M1G074/M3G084)
G) EC motors (nominal voltage 24 / 48 VDC)
Temperature
control module
50002-1-0174
50003-1-0174
Speed setting
PWM 1 - 10 kHz
Speed setting
with
potentiometer
Full speed
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
33 K 4.7 K
10 K
PWM
12 V 12 V
U
Speed display
Alarm
Controller
Counter
red
white
blue
Maximum ripple
3.5%
Tach output
pulses per revolution
GND
I
sink
max. 10 mA
680
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
yellow
Lin/PWM control input
0-10 VDC / PWM
421
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
L
P
E
N
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 2 L brown Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Control input (Impedance 100 k) N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
brown green/yellow blue
+
1
0

V
0
-
1
0

V
P
W
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
GND blue
Tach white Tach output: 1 pulse per revolution
GND
H1) EC motors (size 055, line-fed)
T
a
c
h
G
N
D
white blue
+
-
+
-
Speed setting
PWM 1 - 10 kHz
Speed setting
with variable
resistance
Full speed
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
yellow
white
blue
Lin/PWM control input
0-10 VDC / PWM
green/yellow
PE
blue
N
brown
L
red
Voltage output
+10 V max. 1.1 mA
Tach output
1 pulse per revolution
GND
I
sink
max. 10 mA
680
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
I
max
=
10 mA
U
min
= 15 V
1 F
Mains
50/60 Hz
422
L
P
E
N
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 2 L brown Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Input for set value (impedance 100 k) N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
brown green/yellow blue
+
1
0

V
0
-
1
0

V
P
W
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
GND blue
Tach white Tach output: 1 pulse per revolution
GND
H2) EC motors (size 055, line-fed and constant air flow)
T
a
c
h
G
N
D
white blue
+
-
+
-
Air flow setting
PWM 1 - 10 kHz
Air flow setting
with variable
resistance
Max.
air flow
100% PWM -> Vmax
17% PWM -> Vmin
< 15% PWM -> V=0m
3
/h
start up at > 1.4 V
Air flow setting
1 V - 10 V
10 V -> Vmax
1.7 V -> Vmin
< 1.5 V -> V=0m
3
/h
start up at > 1.4 V
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
yellow
white
blue
Lin/PWM input
for set value
0-10 VDC / PWM
green/yellow
PE
blue
N
brown
L
red
Voltage output
+10 V max. 1.1 mA
Tach output
1 pulse per revolution
GND
I
sink
max. 10 mA
680
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
I
max
=
10 mA
U
min
= 15 V
1 F
Mains
50/60 Hz
423
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
L
P
E
N
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 2 L black Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Control input (Impedance 100 k) N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
black green/yellow blue
+
1
0

V
0
-
1
0

V
P
W
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
GND blue
Tach white Tach output: 1 pulse per revolution
GND
J1) EC motors (size 074, line-fed)
T
a
c
h
G
N
D
white blue
+
-
+
-
Speed setting
PWM 1 - 10 kHz
Speed setting
with variable
resistance
Full speed
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
yellow
white
blue
Lin/PWM control input
0-10 VDC / PWM
green/yellow
PE
blue
N
black
L
red
Voltage output
+10 V max. 1.1 mA
Tach output
1 pulse per revolution
GND
I
sink
max. 10 mA
680
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
I
max
=
10 mA
U
min
= 15 V
1 F
Mains
50/60 Hz
424
L
P
E
N
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 2 L black Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Input for set value (impedance 100 k) N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
black green/yellow blue
+
1
0

V
0
-
1
0

V
P
W
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
GND blue
Tach white Tach output: 1 pulse per revolution
GND
J2) EC motors (size 074, line-fed and constant air flow)
T
a
c
h
G
N
D
white blue
+
-
+
-
Speed setting
PWM 1 - 10 kHz
Air flow setting
with variable
resistance
Max.
air flow
100% PWM -> V=max
approx. 17% PWM -> V=min
< 15% PWM -> V=0
start up at > 1.4 V
Air flow setting
1 V - 10 V
10 V -> V=max
approx. 1.7 V -> V=min
< 1.5 V -> V=0
start up at > 1.4 V
10 K
PWM
12 V
U
Speed display
Alarm
Controller
Counter
yellow
white
blue
Lin/PWM input
for set value
0-10 VDC / PWM
green/yellow
PE
blue
N
black
L
red
Voltage output
+10 V max. 1.1 mA
Tach output
1 pulse per revolution
GND
I
sink
max. 10 mA
680
47 V
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
1 F
Mains
50/60 Hz
10 K
425
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
L
P
E
N
Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 2 L black Mains 50/60 Hz, phase +10 V red
0-10 V / PWM yellow Control input (Impedance 100 k) N blue Mains 50/60 Hz, neutral
PE green/yel Protective earth
Line 1
black green/yellow blue
+
1
0

V
0
-
1
0

V
P
W
M
Line 2
red yellow
Voltage output +10 V max. 1.1 mA
NC white1 Alarm relay, break for failure
COM white2 Alarm relay, COMMON
GND blue GND
K1) EC motors (size 084, line-fed)
N
C
G
N
D
white1
C
O
M
white2 blue
+
-
+
-
white1
NC
white2
COM
Speed setting
PWM 1 - 10 kHz
Speed setting
with variable
resistance
Full speed
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
10 K
PWM
12 V
U
yellow
blue
Lin/PWM control input
0-10 VDC /
PWM
green/yellow
PE
blue
N
black
L
red
Voltage output
+10 V
max. 1.1 mA
GND
Customer circuit
Notes on various control possibilities and their applications
Connection Fan
I
max
=
10 mA
U
min
= 15 V
1 F
Mains
50/60 Hz
Alarm relay:
Break for failure
(2 A, 250 VAC, AC1)
426
P
E
NL
R
S

B
R
S

A
+
1
5

V
0

V
Connector Connection Assignment / function Connector Connection Assignment / function
KL1 KL2 PE RS B
N RS A RS485 interface for ebmBUS; RS A
+15 V
KL1 KL2
L Operation: +15 V (50 mA); Alarm: 0 V
RS485 interface for ebmBUS; RS B
0 V Operation: 0 V; Alarm: +15 V (50 mA)
K2) EC motors (size 084/112 with ebmBUS, mains-powered)
Protective earth
Mains 50/60 Hz, neutral
Mains 50/60 Hz, phase
427
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
LN
P
E
KL3 KL2 KL1
L1) EC motors (size 112, single-phase mains-powered)
Connector Connection Assignment / function Connector Connection Assignment / function
PE KL3 PE Protective earth OUT
KL1 N Mains 50/60 Hz, neutral
L Mains 50/60 Hz, phase
GND GND
GND GND
KL2
0-10 V / PWM
COM Alarm relay, COMMON (2A, 250 VAC, AC1)
+10 V
+20 V
4-20 mA Control / Actual value input
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
NC
NO
Control / Actual value input (Impedance 100 k)
0-10 V / PWM Control / Actual value input
Alarm relay, break for failure
Alarm relay, make for failure
Master output 0-10 V max. 3 mA
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
Supply for external sensor,
20 VDC (20 %) @ 50 mA
L2) EC motors (size 112, three-phase mains-powered)
Connector Connection Assignment / function Connector Connection Assignment / function
PE KL3 PE Protective earth OUT
KL1 L3 Mains; L3
L2 Mains; L2
L1 Mains; L1
GND GND
GND GND
KL2
0-10 V / PWM
COM Alarm relay, COMMON (2A, 250 VAC, AC1)
+10 V
+20 V
4-20 mA Control / Actual value input
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
NC
NO
Control / Actual value input (Impedance 100 k)
0-10 V / PWM Control / Actual value input
Alarm relay, break for failure
Alarm relay, make for failure
Master output 0-10 V max. 3 mA
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
Supply for external sensor,
20 VDC (20 %) @ 50 mA
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
L
1
L
2
L
3
P
E
KL3 KL2 KL1
428
M) EC motors (size 150, three-phase mains-powered)
Connector Connection Assignment / function Connector Connection Assignment / function
PE KL3 PE Protective earth OUT
KL1 L3 Mains; L3
L2 Mains; L2
L1 Mains; L1
GND GND
GND GND
KL2
0-10 V / PWM
COM Alarm relay, COMMON (2A, 250 VAC, AC1)
+10 V
+20 V
4-20 mA Control / Actual value input
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
NC
NO
Control / Actual value input (Impedance 100 k)
0-10 V / PWM Control / Actual value input
Alarm relay, break for failure
Alarm relay, make for failure
Master output 0-10 V max. 3 mA
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
Supply for external sensor,
20 VDC (20 %) @ 50 mA
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
L
1
L
2
L
3
P
E
KL3 KL2 KL1
429
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
R
S

A
R
S

B
R
S

A
R
S

B
G
N
D
0
-
1
0

V
P
W
M
4
-
2
0

m
A
+
2
0

V
+
1
0

V
0
-
1
0

V
P
W
M
G
N
D
O
U
T
N
O
C
O
M
N
C
Mains
50/60 Hz
PC with interface
converter (RS485)
Pressure
sensor
Alarm relay
Connection diagram: Condensing pressure control with master-slave fans
L
1
L
2
L
3
P
E
Master
Mains
50/60 Hz
L
1
L
2
L
3
P
E
Slave
Mains
50/60 Hz
L
1
L
2
L
3
P
E
Slave
430
Distributors, agencies and subsidiaries
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 (0) 26 57 / 16 96
Fax +49 (0) 26 57 / 16 76
[email protected]
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Steinbergweg 6
D-82285 Hattenhofen
Phone +49 (0) 81 45 / 80 92 25
Fax +49 (0) 81 45 / 80 92 26
[email protected]
Nuremberg
Friedrich Klein
Adlerstrae 49/1
D-73540 Heubach
Phone +49 (0) 71 73 / 49 83
Fax +49 (0) 71 73 / 80 53
[email protected]
Offenburg
Dipl.-Ing (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 (0) 78 02 / 98 22 52
Fax +49 (0) 78 02 / 98 22 53
[email protected]
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Mhlhaldenweg 13
D-73207 Plochingen
Phone +49 (0) 71 53 / 92 89 80
Fax +49 (0) 71 53 / 92 89 81
[email protected]
Ulm
Gnter Wilhelm
Allguer Strae 7
D-89269 Vhringen
Phone +49 (0) 73 06 / 92 46 08
Fax +49 (0) 73 06 / 92 46 48
[email protected]
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstrae 3
D-63110 Rodgau - Jgesheim
Phone +49 (0) 61 06 / 84 10
Fax +49 (0) 61 06 / 84 11 11
[email protected]
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grtzmhlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
[email protected]
Munich
A. Schweiger GmbH
Ohmstrae 1
D-82054 Sauerlach
Phone +49 (0) 81 04 / 8 97 0
Fax +49 (0) 81 04 / 8 97 90
[email protected]
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grtzmhlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
[email protected]
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstrae 1
D-74677 Drzbach
Phone +49 (0) 79 37 / 80 29 68
Fax +49 (0) 79 37 / 80 25 78
[email protected]
Contacts
Berlin
Dipl.-Ing. (TH) Jens Duchow
Hndelstrae 7
D-16341 Panketal
Phone +49 (0) 30 / 94 41 49 62
Fax +49 (0) 30 / 94 41 49 63
[email protected]
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Mhnesee-Vllinghausen
Phone +49 (0) 29 25 / 80 04 07
Fax +49 (0) 29 25 / 80 04 08
[email protected]
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr. Hermann-Krause Strae 23
D-63452 Hanau
Phone +49 (0) 61 81 / 18 98 12
Fax +49 (0) 61 81 / 18 98 13
[email protected]
Halle
Dipl.-Ing. (TU) Michael Hanning
Lerchenweg 4
D-06120 Lieskau
Phone +49 (0) 3 45 / 5 51 24 56
Fax +49 (0) 3 45 / 5 51 24 57
[email protected]
Hamburg
Ingenieurbro Breuell GmbH
Dirk Kahl
Elektroingenieur
Grtzmhlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 10
Fax +49 (0) 40 / 53 80 92 84
[email protected]
Kassel
Dipl.-Ing. (FH) Ralph Brck
Hoherainstrae 38
D-35075 Gladenbach
Phone +49 (0) 64 62 / 40 71 10
Fax +49 (0) 64 62 / 40 71 11
[email protected]
Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmhle 2
D-74673 Mulfingen
Phone +49 (0) 79 38 / 81-0
Fax +49 (0) 79 38 / 81-110
[email protected]
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Strae 1
D-78112 St. Georgen
Phone +49 (0) 77 24 / 81-0
Fax +49 (0) 77 24 / 81-13 09
[email protected]
www.ebmpapst.com
ebm-papst
Landshut GmbH
Hofmark-Aich-Strae 25
D-84030 Landshut
Phone +49 (0) 8 71 / 707-0
Fax +49 (0) 8 71 / 707-465
[email protected]
www.ebmpapst.com
fan agent
compact fan agent
motor specialist
motor agent
431
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
Europe
Austria
ebm-papst Motoren & Ventilatoren GmbH
Westbahnstrae 5
A-4490 St. Florian
Phone +43 / 72 24 / 66 01 10
Fax +43 / 72 24 / 66 01 120
[email protected]
www.ebmpapst.at
Belarus
ebm-papst Bel AgmbH
Prospekt Nesavisimosti 11/2 Zimmer 325, 512
BY-220050 Minsk
Phone +375 / 17 / 209 95 61
Fax +375 / 17 / 209 95 61
[email protected]
Belgium
VIBO Benelux B. V.
Sales office Belgium-Luxembourg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 / 16 / 39 62 00
Fax +32 / 16 / 39 62 20
[email protected]
www.vibobenelux.com
Bulgaria
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
[email protected]
Croatia
ebm-papst Industries Kft.
Mtys u. 1/A
H-2220 Vecss
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
[email protected]
www.ebmpapst.hu
Cyprus
MATERO LTD
37, St. Kyriakides Avenue
P.O. Box 51744
CY-3080 Limassol
Phone +357 / 25 / 87 00 30
Fax +357 / 25 / 38 13 66
[email protected]
www.matero.com.cy
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Krtk 379
CZ-66461 Rajhradice u Brna
Phone +420 / 5 / 47 23 26 16
Fax +420 / 5 / 47 23 26 22
[email protected]
www.ebmpapst.cz
Denmark
Jenk A/S
Vallensbkvej 21
DK-2605 Brndby
Phone +45 / 43 / 63 11 11
Fax +45 / 43 / 63 05 05
[email protected]
www.jenk.dk
Estonia
ebm-papst Oy
Eesti Filiaal
Kadaka tee 3
EST-10621 Tallinn
Phone +372 / 655 / 6978
Fax +372 / 655 / 6979
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 / 9 / 88 70 22 0
Fax +358 / 9 / 88 70 22 13
[email protected]
www.ebmpapst.fi
France
ebm-papst SARL
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai-Cedex
Phone +33 / 820 326 266
Fax +33 / 3 / 88 67 38 83
[email protected]
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 / 210 / 951 37 05
Fax +30 / 210 / 951 34 90
[email protected]
www.helcoma.gr
Hungary
ebm-papst Industries Kft.
Mtys u. 1/A
H-2220 Vecss
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
[email protected]
www.ebmpapst.hu
Iceland
RJ Engineers
Stangarhyl 1A
IS-110 Reykjavik
Phone +354 / 567 80 30
Fax +354 / 567 80 15
[email protected]
www.rj.is
Ireland
ebm-papst Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 / 57 86 / 643 43
Fax +353 / 57 86 / 643 46
[email protected]
www.ebmpapst.ie
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 / 03 31 / 83 62 01
Fax +39 / 03 31 / 82 15 10
[email protected]
www.ebmpapst.it
Macedonia
ebm-papst Industries Kft.
Mtys u. 1/A
H-2220 Vecss
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
[email protected]
www.ebmpapst.hu
Netherlands
VIBO Benelux B. V.
Engelseweg 127
Postbus 230
NL-5705 AC Helmond
Phone +31 / 4 92 / 50 29 00
Fax +31 / 4 92 / 50 29 50
[email protected]
www.vibobenelux.com
432
fan agent
compact fan agent
motor specialist
motor agent
ebm-papst Rus GmbH
Nizhegorodskaya 32, str. 15 office 420
RU-109029 Moskau
Phone +7 / 495 / 671 53 93
Fax +7 / 495 / 671 53 95
[email protected]
www.ebmpapst.ru
ebm-papst Rus
Saint-Petersburgs Filial
Zastavskaya 7
RU-196084 Sankt-Petersburg
Phone +7 / 812 / 449 96 07
Fax +7 / 812 / 449 96 07
[email protected]
Serbia & Montenegro
ebm-papst Industries Kft.
Mtys u. 1/A
H-2220 Vecss
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
[email protected]
www.ebmpapst.hu
Spain
ebm-papst Ibrica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 / 91 / 678 08 94
Fax +34 / 91 / 678 15 30
[email protected]
Sweden
Ziehl-ebm AB
ggelundavgen 2
S-17562 Jrflla
Phone +46 / 8 / 761 94 00
Fax +46 / 8 / 36 23 06
[email protected]
www.ebmpapst.se
Switzerland
ebm-papst AG
Rtisbergstrae 1
CH-8156 Oberhasli
Phone +41 / 44 / 732 20 70
Fax +41 / 44 / 732 20 77
[email protected]
www.ebmpapst.ch
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatrk Organize Sanayi
Blgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 / 2 32 / 32 82 090 -91
Fax +90 / 2 32 / 32 80 270
[email protected]
www.akantel.com.tr
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 47
UA-03067 Kiev
Phone +38 / 044 / 206 30 91
Fax +38 / 044 / 206 30 91
[email protected]
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 / 12 45 / 46 85 55
Fax +44 / 12 45 / 46 63 36
[email protected]
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane, East Ilsley
GB-Berkshire RG20 7LG
Phone +44 / 87 07 / 66 51 70
Fax +44 / 87 07 / 66 51 80
A&[email protected]
www.ebmpapst-ad.com
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 / 22 / 76 33 40
Fax +47 / 22 / 61 91 73
[email protected]
www.ziehl-ebm.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236Warszawa
Phone +48 / 22 / 675 78 19
Fax +48 / 22 / 676 95 87
[email protected]
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda
Av. Marechal Gomes da Costa, 35 e
Rua Conselheiro Emidio Navarro
P-1800-255 Lisboa
Phone +351 / 21 / 839 48 80
Fax +351 / 21 / 839 47 59
[email protected]
Romania
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
[email protected]
Russia
ebm-papst Ural GmbH
Rosa Luxembourg Strasse 59
RU-620026 Jekaterinburg
Phone +7 / 343 / 378 31 75
Fax +7 / 343 / 378 31 89
[email protected]
www.ebmpapst.ur.ru
Distributors, agencies and subsidiaries
433
America
Argentinia
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 / 11 46 57 61 35
Fax +54 / 11 46 57 20 92
[email protected]
Brasil
ebm-papst Motores Ventiladores Ltda.
Rua Francisco DAmico, 155
Bairro Pirajussara
BR-06785-290 Taboo da Serra-SP
Phone +55 /11 / 41 38 50 90
Fax +55 /11 / 41 38 50 86
[email protected]
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 / 905 / 420 / 35 33
Fax +1 / 905 / 420 / 37 72
[email protected]
www.ebmpapst.ca
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5
to
Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 / 55 / 50 91 44 44
Fax +52 / 55 / 50 91 44 43
[email protected]
www.ebmpapst.com.mx
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 / 860 / 674 15 15
Fax +1 / 860 / 674 85 36
[email protected]
www.ebmpapst.us
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 / 313 / 406 80 80
Fax +1 / 313 / 406 80 81
[email protected]
www.ebmpapst-automotive.us
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 / 11 / 794 34 34
Fax +27 / 11 / 794 50 20
[email protected]
www.ebmpapst.co.za
G
e
n
e
r
a
l

i
n
f
o
r
m
a
t
i
o
n
A
C

a
x
i
a
l

f
a
n
s
A
C

a
x
i
a
l
S

s
e
r
i
e
s
A
C

a
x
i
a
l
K

s
e
r
i
e
s
A
C

a
x
i
a
l
A

s
e
r
i
e
s
E
C

a
x
i
a
l

f
a
n
s
E
C

a
x
i
a
l
S

s
e
r
i
e
s
Q
-
m
o
t
o
r
E
S
M
E
C
-
S
Y
S
T
E
M
S
A
c
c
e
s
s
o
r
i
e
s
T
e
c
h
n
o
l
o
g
y
C
o
n
t
a
c
t
s
434 435
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 / 21 / 50 46 01 83
Fax +86 / 21 / 50 46 11 19
[email protected]
Hong Kong
ebm-papst Ventilator (Shanghai) Co., Ltd.
Hong Kong Representative Office
Unit Nos. 13, 9/F, Technology Park
18 On Lai Street, Sha Tin, N.T.
HK-Hong Kong P.R. of China
Phone +852 / 21 45 / 86 78
Fax +852 / 21 45 / 76 78
[email protected]
India
ebm NADI International Pvt Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 / 44 / 25 37 25 56
Fax +91 / 44 / 25 37 11 49
[email protected]
www.ebmnadi.com
Indonesia
ebm-papst Indonesia
Representative Office
Jalan Puri Kencana, Blok K7/3T
RI-Jakarta 11610
Phone +62 / 21 / 582 / 31 18
Fax +62 / 21 / 582 / 31 17
[email protected]
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 / 3 / 910 03 00
Fax +972 / 3 / 579 66 79
[email protected]
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 / 45 / 470 / 57 51
Fax +81 / 45 / 470 / 57 52
[email protected]
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 / 2 / 36 62 / 13 24
Fax +82 / 2 / 36 62 / 13 26
[email protected]
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Block F1, 9A-4, Jalan PJU 1/42
Dataran Prima
MAL-47301 Petaling Jaya
Phone +60 / 3 / 78 06 54 40
Fax +60 / 3 / 78 06 54 41
[email protected]
Singapore
ebm-papst SEA Pte. Ltd.
23 Ubi Road 4, #05-00
Olympia Industrial Building
SGP-Singapore 408620
Phone +65 / 68 42 84 38
Fax +65 / 68 42 84 39
[email protected]
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 / 7 / 557 42 68
Fax +886 / 7 / 557 27 88
[email protected]
Thailand
ebm-papst Thailand Co. Ltd.
Representative Office
99/349 Chaeng Wattana Road, Laksi
Bangkok 10210, Thailand
Phone +66 / 2 / 576 / 15 24-5
Fax +66 / 2 / 576 / 15 42
[email protected]
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 / 4 / 886 08 26
Fax +971 / 4 / 886 08 27
[email protected]
Australia
Australia
ebm-papst Australia Pty Ltd.
2 Silverton Close
AUS-Laverton North, Victoria, 3026
Phone +61 / 3 / 83 25 64 00
Fax +61 / 3 / 83 25 64 64
[email protected]
www.ebmpapst.com.au
New Zealand
ebm-papst Australia Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 / 9 / 837 18 84
Fax +64 / 9 / 837 18 99
[email protected]
www.ebmpapst.com.au
Distributors, agencies and subsidiaries
fan agent
compact fan agent
motor specialist
motor agent
434 435
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 / 21 / 50 46 01 83
Fax +86 / 21 / 50 46 11 19
[email protected]
Hong Kong
ebm-papst Ventilator (Shanghai) Co., Ltd.
Hong Kong Representative Office
Unit Nos. 13, 9/F, Technology Park
18 On Lai Street, Sha Tin, N.T.
HK-Hong Kong P.R. of China
Phone +852 / 21 45 / 86 78
Fax +852 / 21 45 / 76 78
[email protected]
India
ebm NADI International Pvt Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 / 44 / 25 37 25 56
Fax +91 / 44 / 25 37 11 49
[email protected]
www.ebmnadi.com
Indonesia
ebm-papst Indonesia
Representative Office
Jalan Puri Kencana, Blok K7/3T
RI-Jakarta 11610
Phone +62 / 21 / 582 / 31 18
Fax +62 / 21 / 582 / 31 17
[email protected]
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 / 3 / 910 03 00
Fax +972 / 3 / 579 66 79
[email protected]
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 / 45 / 470 / 57 51
Fax +81 / 45 / 470 / 57 52
[email protected]
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 / 2 / 36 62 / 13 24
Fax +82 / 2 / 36 62 / 13 26
[email protected]
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Block F1, 9A-4, Jalan PJU 1/42
Dataran Prima
MAL-47301 Petaling Jaya
Phone +60 / 3 / 78 06 54 40
Fax +60 / 3 / 78 06 54 41
[email protected]
Singapore
ebm-papst SEA Pte. Ltd.
23 Ubi Road 4, #05-00
Olympia Industrial Building
SGP-Singapore 408620
Phone +65 / 68 42 84 38
Fax +65 / 68 42 84 39
[email protected]
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 / 7 / 557 42 68
Fax +886 / 7 / 557 27 88
[email protected]
Thailand
ebm-papst Thailand Co. Ltd.
Representative Office
99/349 Chaeng Wattana Road, Laksi
Bangkok 10210, Thailand
Phone +66 / 2 / 576 / 15 24-5
Fax +66 / 2 / 576 / 15 42
[email protected]
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 / 4 / 886 08 26
Fax +971 / 4 / 886 08 27
[email protected]
Australia
Australia
ebm-papst Australia Pty Ltd.
2 Silverton Close
AUS-Laverton North, Victoria, 3026
Phone +61 / 3 / 83 25 64 00
Fax +61 / 3 / 83 25 64 64
[email protected]
www.ebmpapst.com.au
New Zealand
ebm-papst Australia Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 / 9 / 837 18 84
Fax +64 / 9 / 837 18 99
[email protected]
www.ebmpapst.com.au
Distributors, agencies and subsidiaries
fan agent
compact fan agent
motor specialist
motor agent
37779-7-8811 KO-08/07-10,8
Printed in Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmhle 2
D-74673 Mulfingen
Phone +49 (0) 7938 / 81-0
Fax +49 (0) 7938 / 81-110
[email protected]
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Strae 1
D-78112 St. Georgen
Phone +49 (0) 7724 / 81-0
Fax +49 (0) 7724 / 81-1309
[email protected]
ebm-papst
Landshut GmbH
Hofmark-Aich-Strae 25
D-84030 Landshut
Phone +49 (0) 871/ 707-0
Fax +49 (0) 871/ 707-465
[email protected]
version 07