Appendix Flash Drum
Appendix Flash Drum
with parameter:
W
L
= 10967 kg/hour
W
v
= 1727.257 kg/hour
A = -1.877478
B = -0.814580
C = -0.187074
D = -0.014522
E= -0.0010148
(black well parameter)
Calculate Cross Sectional Area and Diameter
)
Calculate Length and Inlet Nozzle
Set the length or diameter ratio either by rule of thumb or by the required liquid surge
volume. For horizontal flash drum, the rule of thumb is that L/d usually ranges to 3 to 5.
We choose 3 as ratio. So the H total is 4.409 m
Calculate Thickness
o Material that used is Low Alloy Steel SA-301 A as material which has
specification:
o Allowable stress = 16,250 psia
o Double welded butt joint eff = 85%