1.2.2 Storage
The amount of storage space and the type of storage will depend on:
The size of the kitchen.
Menu.
The volume of business.
Delivery frequency.
The length of storage.
The type of storage (frozen, refrigerated or dry).
Storage of meats, poultry and fish should be taken into consideration when designing the
kitchen and kept separate
from dry foods, vegetables, fruit and pastry.
1.2.3 Preparation and Cooking
The main preparation areas in food premises are for:
Meat preparation.
Poultry preparation.
Fish preparation.
Vegetable preparation.
Pastry/dessert preparation.
All food preparation areas should be separate from the cooking area.
1.2.4 Clean Crockery
Storage for clean crockery should be close to the washing up facility to minimise excess
movement around the kitchen
and ideally in a separate room due to the air pollution in a kitchen.
WORK TRIANGLE
WORK AISLE
The width of a work aisle should be at least 42 for one cook and at least 48 for
multiple cooks. Measure between the counter frontage, tall cabinets and/or
appliances.
ADA/ANSI Guidelines:
A clear floor space of at least 30 by 48 should be
provided at each kitchen appliance. Clear floor
spaces can overlap. (ANSI A 117.1 305.3, 804.6.1).
(ANSI A 117.1 404.2.3.1)
In a U-shaped kitchen, plan a minimum clearance of
60 between opposing arms. (ANSI A117.1 804.2.2,
1003.12.1.2).
Include a wheelchair turning space with a diameter
of at least 60, which can include knee* and toe*
clearances. (ANSI A117.1 304.3.1).
A wheelchair turning space could utilize a T-shaped
clear space, which is a 60 square with two 12 wide
x 24 deep areas removed from the corners of the
square. This leaves a minimum 36 wide base and
two 36 wide arms. T-shaped wheelchair turning
spaces can include knee and toe clearances. (ANSI
A117.1 304.3.2).
WALKWAYS
The width of a walkway should be at least 36.
Code Requirement:
Manufacturers specifications must be followed. (IRC G 2407.1, IRC G 2447.1).
The minimum required exhaust rate for a ducted hood is 100 cfm and must be ducted to
the outside. (IRC M 1507.3).
Make-up air may need to be provided. Refer to local codes. (IRC G 2407.4).
Universal Design
Guideline: Ventilation
controls should be
placed 15 44 above
the floor, operable with
minimal effort, easy to
read and with minimal
noise pollution.
ADA/ANSI Guidelines:
Operable parts should be operable with
one hand and not require tight grasping,
pinching or twisting of the wrist. The
force required to activate operable parts
should be 5 pounds maximum. (ANSI
A117.1 309.4).
Where a forward or side reach is
unobstructed, the high reach should be
48 maximum and the low reach should
be 15 minimum above the floor.(ANSI
A117.1 308.2.1 and 308.3.1).
Where a forward or side reach is
obstructed by a 20 25 deep counter,
the high reach should be 44 maximum.
(ANSI A117.1 308.2.2)
SIGNAGE
12.1 Emergency Signage
12.1.1 Exit Signs
Exit signs are required to direct people to exit doors in the case of an emergency.
12.1.2 Fire Emergency Signage
It is necessary in a commercial kitchen to provide signage that tells
Signs detailing the emergency evacuation plan for the business. Staff should be made
aware of where emergency
evacuation procedures are written down.
Instructional signs adjacent to fire extinguishers, fire blankets and fire hose reels detailing
their correct use.
12.1.3 First Aid Signage
Signs should be installed to clearly mark the location of first aid kits.
12.2 Hygiene Signage
12.2.1 Personal Hygiene Signage
Personal hygiene of staff is important to prevent contamination of food.
12.2.2 Kitchen Hygiene Signage
Posters should be displayed that detail the procedures necessary to keep the kitchen clean
and hygienic..
12.2.3 Check Lists
To keep track of hygiene and cleanliness issues, a checklist of procedures is recommended.
The checklist should provide
a brief description of what is required.
STAFF AMENITIES
13.1 Storage of Personal Items`
Staff should be provided with adequate and secure storage for clothing and personal
belongings.
13.2 Change Rooms
Staff should be provided with dedicated change rooms, particularly when they are required to
wear uniforms.
13.3 Toilets
It is essential that staff have access to toilets.
For a small business located in a shopping centre, use of the centres public toilets may be
adequate.
For larger businesses, staff may share the toilet facilities provided for patrons
Where more than 10 staff are employed, separate male and female toilets should be provided.
Toilets must not open directly into kitchens or food storage areas and should be accessed via
airlocks with self-closing doors. toilets must be adequately ventilated in accordance with the
Building Act 1984.
13.4 Storage of Office Materials
Office materials and paperwork should be stored in a room designated for office use
13.5 Wash Hand Basins
Staff must have access to wash hand basins / Quadwash facilities after visits to the
toilets/smoking areas(contamination from lighters / cigarette packets).
Wash hand basins must be located where staff move from one area to another e.g. from prep
area to cooking area.
FIRE SAFETY
Basic fire precautions are:
All areas should be kept clean from dust, dirt and oil to limit fire damage.
All cooking and high-risk appliances should be watched when in use.
14.1 Emergency Procedures
All kitchens must have a written emergency evacuation plan in place.
14.1.1 Emergency Manuals
All manuals for emergency devices, solutions to dangerous situations and other emergency
instructions etc. should be kept in the same place. They must be clearly labeled, well organized
and easy to understand.
14.2 Emergency Devices
Emergency devices should be dispersed around the kitchen, not all in the same area.
Emergency equipment should be serviced at least once a year.
14.2.1 Fire Extinguishers
The most common cause of serious fires in commercial kitchens is the over-heating of deep
fryer oil.
It is recommended that all extinguishers / blankets used in the kitchen are suitable for hot oil
fires.
How many extinguishers?
The number of extinguishers is dependent on the size of the kitchen.
Location
They should be in a main thoroughfare, preferably along the exit route.
They need to be easy to access in a hurry.
They should be 100mm high off the floor; the top of the extinguisher should be 1200mm from
the floor.
For electrical fires the extinguisher must be closer than 40m from the appliances.
For cooking oils and fats the extinguishers must be placed between 2 and 20m from the risk. In
a
commercial kitchen 20m is too far away, it is safer to keep them within 10m.
REFERENCE
REFERENCE:
http://scullmeister.blogspot.in/2014/05/tiny-commercial-kitchen-layout.html
REFERENCE
http://www.viahouse.com/2013/07/commercial-kitchen-design-ofdirties/extravagant-modern-style-commercial-kitchen-design-spacious-room-design/
REFERENCES
http://www.alulinegms.com/sitedata/files/kitchen_design_guide.pdf
http://starcraftcustombuilders.com/kitchen.design.rules.htm#.VFMZKvmSxz4
https://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitc
hen.pdf
http://en.wikipedia.org/wiki/Kitchen_work_triangle
ADA/ANSI STANDARDS