K8 H8 Operation Manual
K8 H8 Operation Manual
Easy to Use
The device has three indications:
Users Guide
Green flashes
Safe indication
The faster the Green LED flashes the higher the level of radiation
Red flashes & audible alarm
Operations
General Description
Battery Replacement
Remove two screws from the cover.
Slide the battery out
Push in a new CR2032 lithium battery
Put cover and screws back (do not force)
The unit is ready for use
1.
2.
3.
4.
5.
Green LED flashes every second at the distance for various isotopes
60
40
20
0
1 Ci
Co-60
100 mCi
10 mCi
Cs-137
1 mCi
I-131
100 Ci
Ir-192
10 Ci
Ra-226
Detection Range
With 20 keV to 10 MeV detection range capability, it detects both low energy
emission radionuclides such as I-125 & Pd-103 commonly used in nuclear
medicine and radiation therapy in hospitals, and high energy ones such as Cs137, Co-60, Ir-192, I-131, U-235, & Ra-226. It also detects high- energy beta
emitters: Y-90 & P-32. Such radionuclides are possible for use in a dirty bomb.
40
(inches)
30
20
10
0
1 mCi
100 Ci
Co-60
10 Ci
Cs-137
Specifications
Detector
Detection
Sensitivity
2 mrem/hr Warning
Warning Signals
Adjustable Range
Alarm
Solid-state detector.
X & gamma: 15 KeV and 10 MeV
Electrons & beta particles: 600 KeV and up
For Cs-137, e.g., Green LED flashes approximately
every 5 seconds in a 0.5 mrem/hr field and every 2.5
seconds in a 1 mrem/hr field
Green LED flashes rapidly, approx. every second
Red flashes & alarm beeping @ ~10 mrem/hr
***Custom setting available
0.5 1,000 mrem/hr with a trimmer option available
80 dB @10 cm
Battery
Battery Life
Power Indication
Natural Radiation