Installation ActWin-H (Version 3.52)
From CD:
Insert the ActWin CD in your CD driver.
Your web browser will start with Welcome to ActWin 3.51A and ActWin-E installation.
Choose Install ActWin
Select Run, don not select save file
You can always start the installation manually. Click on Windows Start button. Enter
D:\INSTALL.EXE. As D you should enter your CD driver letter.
Contents of the CD
\ActWin-E
\Cables
\Demo_projects
\Dongle
\Manuals
\Tutorial
\USR_LIB
V3.16/V3.52
Driver information
Hitachi EH-Nano
Hitachi EH-Micro:
Hiatchi H-series:
With this driver you can program all Hitachi PLC series H
(HB, H200-252, EH-150, Micro-EH and H300-4004). Use
this driver if you should program series HB, H200H252, EH-150 or H300-H4004
V3.16/V3.52
License disk:
If a license disk are included in your software package, you have to install this license .
Run the file "INSTALL.EXE" from the license disk. Install the license in same directory as you have install
ActWin in.
Make same procedure for ActWin-E
Dongle license:
ActWin support a new type of dongle. It exist 2 types of dongle, USB or parallel.
The parallel dongle are the world's smallest parallel port hardware key
You only need to install dongle support if your package includes a dongle!
The installation needs some files. These files are included on the CD (in the Dongle directory)
or you can download them from the Internet.
www.actwin.se
Extract all files and subdirectories to your hard disk.
V3.16/V3.52
Communication setup MICRO-EH
Cable:
For programming Hitachi series Micro-EH use ActCab-EH2
ON
DIPSW
2 3 4
1
ON
ON
OFF
OFF
OFF
2
OFF
OFF
OFF
OFF
ON
3
ON
OFF
ON
OFF
OFF
4
OFF
OFF
OFF
OFF
OFF
Setup
38.4 k bps
19.2 k bps
9600 bps
4800 bps
Modem communication
Remarks
Normal
Default
=
=
=
=
Value
Speed
Remarks
16#8000
16#8100
16#8200
16#8300
4800
9600
19200
38400
Default
Normal
Value after
changes
16#0000
16#0100
16#0200
16#0300
V3.16/V3.52
Communication setup EH-150
Cable:
For programming Hitachi series EH-150 use cable ActCab-EH2
Port 1 & 2
Normal setup:
With this setup its possible to program or monitor on both ports at 19200 baud .
1,3,5 = ON
2,4,6,7,8 = OFF
Toggle switch = ON
Switch
nr
ON
OFF
"REMOTE"
Normal mode
Modem control
TRNS0 operation
3,4
Speed port 1
ON
ON
4,800 baud
OFF
ON
9,600 baud
ON
OFF
19,200 baud
OFF
OFF
38,400 baud
Dedicated port
Remarks
General-purpose port
PHL
Speed port 2
ON
OFF
9,600 bps
ON
ON
38,400 bps
OFF
OFF
4,800 bps
OFF
ON
Port 1 operation
PHL is high in the cable Actcab-EH2
19,200 bps
(System mode)
Should be OFF
(System mode)
Should be OFF
Toggle switch
2)
ON
Should be ON
Toggle-switch
ON
8
7
6
5
4
3
2
1
1)
DIP-switch
CPU module
Normal
r
OFF
78
2) Toggle switch
V3.16/V3.52
Communication setup Hitachi series HB, H200-H252, H300-H4004.
Cable:
Use cable ActCab-H2
The transmission speed is set to 19200 in the cable Actcab-H2.
To use other transmission speed, following change is needed in the cable.
D-Sub PLC side: Short cut 8 and 14 = 19200 baud
D-sub PLC side: Short cut 8 and 13 = Transmissions speed set by switches on the PLC.
Series HB:
No.
Function
2400 baud
1
Baud rate
ON
settings
2
ON
Factory setting: 1=ON, 2=OFF
Setting
4800 baud
ON
OFF
9600 baud
OFF
ON
Series H200-H252
For the possibility to Stop/Start PLC from the PC, set switch 4 to ON. (Not possible on
CPU-02H)
No. Function
1
2
3
Setting
2400 baud
4800 baud
9600 baud
19200 baud
ON
ON
OFF
OFF
ON
OFF
ON
OFF
Refresh mode: ON
Direct mode OFF
I/O processing
system
4
Remote setting
Factory setting: 1,3=ON 2,4=OFF
Remote: ON
Normal: OFF
V3.16/V3.52
Communications setup Hitachi series EC/EM(CPM-E3).
Series EC:
Series EM:
No.
PRG
COM1
COM2
Function
Mode
selector
Programmer
(PGMJ/PGMJ-R)
X
Setup
Actsip/
ActGraph
(X)
X
ActWin-E
Please note: If you change the switch the PLC has to be restarted
In Actsip-E/ActGraph-E: Use mode 2 protocol are depending on the mode selector switch
YES= COM2, NO = COM1