Ref Testing - MV Panel Rev
Ref Testing - MV Panel Rev
Date of Testing ..
Relay Details:
Name of Relay
Relay Make:
Serial No.
Type
Current
rating
Voltage rating
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Make:
Ratio
Class
Knee point V (Vkp)
In at Vkp
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Serial Numbers
Red CT
Yellow CT
Blue CT
Neutral CT
-----------------------------------------------------------------------------------------
-----------------------------------KVA
11KV/ ---------------------- %
---------------------
Vector Group
--------------------Year of Manufacture ---------------------Resistance of CT
R Phase
Y Phase
B - Phase
Neutral
----------------------------------------------------------------------------------
Lead resistance
Red
Yellow
Blue
Neutral
-------------------------------------------------------------------------------------------
Resistance of relays:
Current Setting
0.5A
1.0 A
2A
Resistance
Ohm
------------Ohm
------------Ohm
Amp
Ohm
For Stable Operation of the REF relay the following condition should be
satisfied
I op (Rst + Rr)
>
Where
Iop
Rst
Rr
IFs
IF
Ifs
Rl
IF = TX capacity / 3 V x pu Impedance
CT knee point requirement calculation
Vkp = 2 x Iop (Rst+Rr+2RL)
Minimum VKp should be as above equation
Where Vkp
= Minimum knee joint voltage
Iop
= Relay setting current
Rst
= Stabilizing resistor
(Telephone: 4845623-5622 Fax 4845707)
EDM/PR /MV-01
Rr
2RL
= Relay resistance
= Loop resistance
Y-Phase
Voltag Current
e
in Milli
in
Amps
Volts
B Phase
Voltage
Current
In volts
In Milli
Amps
Neutral
Voltag
Current
e
In Milli
In
Amps
volts
Note :-To prove the knee point, graph should be Plotted and attached
2. SECONDARY INJECTION OF THE RELAY
Setting
0.5
075
1.0
1.25
1.50
1.75
2.00
Pickup
(Refer Fig a)
Relay
Current
Red
Injected
R-N
Y-N
B-N
Relay
Curre
nt
Red
R-N
Y-N
B-N
Y
B
N
S1
S2
S1
S2
S1
S2
S1
S2
Fig (a)
Inject current through R-N ,Y-N & B-N and record the values in table 3
(Telephone: 4845623-5622 Fax 4845707)
EDM/PR /MV-01
S1
S2
S1
S2
S1
S2
S1
S2
Fig (b)
Inject current through R-N, Y-N & B-N and record the values in table 4
Battery and Battery charger Make..
Confirm the Battery charger and Battery voltage Volts
Panel Manufacturer
.
CR. Number.
Name& Signature,..
Date
Stamp
Contractor
CR
.Number.
Name &Signature
Date.
Stamp
Consultant..
License Number
Name &Signature
Date
Stamp
.
Name & Signature of Protection Engineer
Kbs/nkk