[All references are from IS: 456-2000 except otherwise mentioned]
Design of Column at C (Intermediate Column)
Total axial load on the column = 546.423 6 = 3278.538 KN
MUX = 54.47 KN-m
MUY = 40.71 KN-m
Size of column = 350 mm 450 mm
Check for Eccentricity:
[Cl 25.4]
e=
l
500
b
30
3000
500
450
30
= 21 mm > 20 mm
e = 21 mm
0.05D = 0.05 450 = 22.5 mm > e
Hence O.K.
Check for Slenderness Ratio:
Considering partial fiidity at top & bottom, le = 0.8l
le
b
0.8 X 3000
350
= 6.857 < 12
So, it is a short column.
Check for P-M interaction:
32
2
d' = 40 + 8 +
= 64 mm
D = 450 mm
d'
b
64
350
= 0.18
Assume, pt = 4%
pt
f ck
4
25
= 0.16
d'
D
64
450
= 0.14
PU
f ck bd
3278.538 X 1000
25 X 350 X 450
= 0.83
From chart 45 of SP-16,
or,
M Ux
= 0.04
f ck b D
M Ux
= 0.04 25 350 4502 = 70.875 KN-m > 54.47 KN-m
Hence O.K.
From chart 46 of SP-16,
or,
M Uy
= 0.03
f ck D b
M Uy
= 0.03 25 450 3502 = 41.344 KN-m > 40.71 KN-m
Hence O.K.
From Cl. 39.6,
PUZ = 0.45 fck AC + 0.75 fy ASC = 0.45 250.96350450 + 0.754150.04350450 =
3661.875 KN
PU
PUZ
3278.538
3661.875
= 0.895
n = 2.0
M UX
M UX 1
( )
M UY
M UY 1
( )
54.47
70.875
40.71
41.344
= 1.06 1
O.K.
ASC = 0.04 X 350 X 450 = 6300 mm2
Let us provide 4 nos. 32 & 4 nos. 28 bars. [ASC provided = 6560 mm2]
Design of Lateral Tie:
Diameter of lateral ties should be maximum of the following:
a. X Greatest dia. of main bar = X 32 = 8 mm
b. 6 mm
Let us provide 8 mm links.
Hence
Pitch should be minimum of the following:
a. Least lateral dimension = 350 mm
b. 16 X Least dia of main bar = 16 X 28 = 448 mm
c. 300 mm
Let us provide 8 mm links @ 300 mm c/c
Design of Column at C (Corner Column)
Total axial load on the column = 296.406 6 = 1778.436 KN
MU = 122.49 KN-m
Size of column = 350 mm 450 mm
Check for Eccentricity:
[Cl 25.4]
e=
l
500
b
30
3000
500
450
30
= 21 mm > 20 mm
e = 21 mm
0.05D = 0.05 450 = 22.5 mm > e
Hence O.K.
Check for Slenderness Ratio:
Considering partial fixidity at top & bottom, le = 0.8l
le
b
0.8 X 3000
350
So, it is a short column.
= 6.857 < 12
Check for P-M interaction:
28
2
d' = 40 + 8 +
= 62 mm
D = 450 mm
d'
D
64
450
= 0.14
Assume, pt = 4%
pt
f ck
PU
f ck bd
2.5
25
= 0.10
1778.436 X 1000
25 X 350 X 450
= 0.45
From chart 45 of SP-16,
or,
M Ux
f ck b D2
M Ux
= 0.09
= 0.09 25 350 4502 = 159.469 KN-m > 122.49 KN-m Hence O.K.
ASC = 0.025 X 350 X 450 = 3937.5 mm2
Let us provide 8 nos. 28 bars. [ASC provided = 4928 mm2]
Design of Lateral Tie:
Diameter of lateral ties should be maximum of the following:
c. X Greatest dia. of main bar = X 28 = 7 mm
d. 6 mm
Let us provide 8 mm links.
Pitch should be minimum of the following:
d. Least lateral dimension = 350 mm
e. 16 X Least dia of main bar = 16 X 28 = 448 mm
f. 300 mm
Let us provide 8 mm links @ 300 mm c/c