0% found this document useful (0 votes)
82 views

Geecy Industrial Services Pvt. LTD

GeeCy Industrial Services conducted phased array ultrasonic testing on welds AS34#AS35 of the Chenab Bridge Project in Jammu. The testing found two planar indications requiring repair between 483-500mm and 662-669mm. All other indications were found to be acceptable per the EN 1712 Level II acceptance criteria. The report documents the NDT equipment used, test parameters, and provides a detailed list of indications found.

Uploaded by

birthinonce
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views

Geecy Industrial Services Pvt. LTD

GeeCy Industrial Services conducted phased array ultrasonic testing on welds AS34#AS35 of the Chenab Bridge Project in Jammu. The testing found two planar indications requiring repair between 483-500mm and 662-669mm. All other indications were found to be acceptable per the EN 1712 Level II acceptance criteria. The report documents the NDT equipment used, test parameters, and provides a detailed list of indications found.

Uploaded by

birthinonce
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

GEECY INDUSTRIAL SERVICES PVT. LTD.

M-206, B-6, Sector 3, Millenium Business Park, Navi Mumbai - 400 710
Tel.no.+91 22 2778 2952 /53 Fax : 2778 2954
Email : [email protected] Web : www.ndtgeecy.com

Customer Name :

M/s. Konkan Railway Corporation Ltd.

Contract No.

Location of work
site :

Chenab Bridge Project Undertaking,


Jammu

Contact person :

Mr. Rashid

Report No. :

GISPL/KRCL/PAUT-01

Date of test :

03/01/2015

Page __of __

C-1123

Examination Data
Item No.

AS34#AS35

DWG. No.

KR/CHENAB/2612/B/S
U/001

Material

Testing
Subject

Weld Metal/
HAZ

Thickness

12/16 mm

Weld Type

BW/SV (Inverted)

Weld
Process

GMAW+SAW

1G

Procedure
No.

GISPL/PAUT/00

Weld
GMAW+FCAW Position

CS

Instrument Data
Equipmen
t

OMNISCAN
Module Sr. No.
MX2

OC-002668

PAUT
Probe

5L64-A12

PAUT Wedge

SA12 N55S-IHC

Couplant

Water/Star
ch

Encoder
resolution

12 mm/sec

Encoder
AXIS

1 AXIS

Surface
condition

Smooth

Encoder Type :

OmniScan
Serial

Wheel

OMNI 2-102560

String pot

Other

Sample
Interval

1 mm

Index Offset
for PAUT

-20 mm

Reflector

3mm SDH

Acceptance
Criteria

EN 1712 Level II

GROUP 1
First Element: 42

Sectorial Angles: 45 & 70


GROUP 2

Approved By :
NDT Agency

KRCL

TPI

Name :

Name :

Name :

Sign

Sign

Sign

Date

Date

Date

____________________________________________________________________________________________________________

GISPL/F/PAUT/06 Rev.3.00

GEECY INDUSTRIAL SERVICES PVT. LTD.


M-206, B-6, Sector 3, Millenium Business Park, Navi Mumbai - 400 710
Tel.no.+91 22 2778 2952 /53 Fax : 2778 2954
Email : [email protected] Web : www.ndtgeecy.com

Customer Name :

M/s. Konkan Railway Corporation Ltd.

Contract No.

Location of work
site :

Chenab Bridge Project Undertaking,


Jammu

Contact person :

Mr. Rashid

Report No. :

GISPL/KRCL/PAUT-01

Date of test :

03/01/2015

Page __of __

First Element: 28

Line No. /Joint


No.

AS 34#35
(0-1000 mm)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(1000-12500)
AS 34#35
(12500-13500)
Weld Info.

C-1123

Sectorial Angles:50 & 70

Sr
.
N
o.

Type
of
Indicat
ion

Star
t

Lengt
h

Dept
h

Heig
ht

[m
m]

[mm]

[mm]

[mm
]

Planar

483

17

Planar

12

7.5

3
4
5
6
7
8
9

662
8
665
9
670
6
746
6
874
3
913
5
111
51
-

Defect
Location
From
weld
center(m
m)

Result

-2

Repair

2.5

+5

Repair

Non5.7
7.8
1.6
+2
Planar
Non6
8.3
0.8
+6
Planar
Non11.1
7.9
0.7
-2
Planar
Non20
6.6
1.7
+5
Planar
Non5
7.3
1.3
0
Planar
Non5
7.8
1
0
Planar
NonPlanar
Areas inspected
Start Position ( mm )

Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Datum Point

Start Area

NOTE: Approved By :
NDT Agency

KRCL

TPI

Name :

Name :

Name :

Sign

Sign

Sign

Date

Date

Date

____________________________________________________________________________________________________________

GISPL/F/PAUT/06 Rev.3.00

GEECY INDUSTRIAL SERVICES PVT. LTD.


M-206, B-6, Sector 3, Millenium Business Park, Navi Mumbai - 400 710
Tel.no.+91 22 2778 2952 /53 Fax : 2778 2954
Email : [email protected] Web : www.ndtgeecy.com

Customer Name :

M/s. Konkan Railway Corporation Ltd.

Contract No.

Location of work
site :

Chenab Bridge Project Undertaking,


Jammu

Contact person :

Mr. Rashid

Report No. :

GISPL/KRCL/PAUT-01

Date of test :

03/01/2015

Page __of __

C-1123

Approved By :
NDT Agency

KRCL

TPI

Name :

Name :

Name :

Sign

Sign

Sign

Date

Date

Date

____________________________________________________________________________________________________________

GISPL/F/PAUT/06 Rev.3.00

GEECY INDUSTRIAL SERVICES PVT. LTD.


M-206, B-6, Sector 3, Millenium Business Park, Navi Mumbai - 400 710
Tel.no.+91 22 2778 2952 /53 Fax : 2778 2954
Email : [email protected] Web : www.ndtgeecy.com

Customer Name :

M/s. Konkan Railway Corporation Ltd.

Contract No.

Location of work
site :

Chenab Bridge Project Undertaking,


Jammu

Contact person :

Mr. Rashid

Report No. :

GISPL/KRCL/PAUT-01

Date of test :

03/01/2015

Page __of __

C-1123

AS 34#35 (0-1000 mm)

Approved By :
NDT Agency

KRCL

TPI

Name :

Name :

Name :

Sign

Sign

Sign

Date

Date

Date

____________________________________________________________________________________________________________

GISPL/F/PAUT/06 Rev.3.00