1) This document provides safety data for the hardened resin product GUROFLEX MV. It contains no registered dangerous ingredients and does not pose risks to human health or the environment under normal use conditions. 2) In the event of fires involving this product, firefighting personnel should use extinguishing powder, carbon dioxide, or foam. The product may release carbon dioxide, carbon monoxide, and small amounts of butadiene when burned. 3) Spills of the product can be cleaned up mechanically. Personal protective equipment is not required under normal handling conditions. Proper storage does not require special conditions.

Uploaded by

steve_osullivan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
334 views3 pages

Guroflex MV English

1) This document provides safety data for the hardened resin product GUROFLEX MV. It contains no registered dangerous ingredients and does not pose risks to human health or the environment under normal use conditions. 2) In the event of fires involving this product, firefighting personnel should use extinguishing powder, carbon dioxide, or foam. The product may release carbon dioxide, carbon monoxide, and small amounts of butadiene when burned. 3) Spills of the product can be cleaned up mechanically. Personal protective equipment is not required under normal handling conditions. Proper storage does not require special conditions.

Uploaded by

steve_osullivan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

EG-Safety Data Sheet according to 91/155/EWG

0 Data Sheet Information

Date Prepared:
04.03.2003
Substituted Data Sheet:
1 Commercial Name: GUROFLEX MV hardened
Manufacturer: Tyco electronics Jordan GmbH & Co. KG

Page 1 of 3

Telephone: 030/720809-0
Telefax: 030/720809-49

2 Chemical Charakteristics
Hardened resin under application of filled, modified hydrocarbon resin.
Dangerous Ingredients: No registrated dangerous ingredients.
3 Possible Danger
Special Hints According Danger for Human and Environment: none
4 First Aid Procedures:
General Procedures:

---

Hints for Doctor:

---

After Contact with Skin:

No special procedure.

After Contact with Eye:

No special procedure.

After Swallow:

No special procedure.

After Inhalation of Aerosol or Vapor in high Concentration: No special procedure.


5 Fire Fighting Measures
Suitable Erase Material:

Erase powder, carbon dioxide, extinguishing foam,


waterspray
At fire release of carbon dioxide, carbon monoxid and
small parts of butadiene are possible.
Using breath mask for combating fire.

Danger Through Arising Gases:


Special Protection Equipment:
Other Instructions:
6 Accidental Release Measures

---

Human Protection:

No special procedure.

Environment Protection:

No special procedure.

Procedure for cleaning:

Remove mechanical.

Recommended Cleaning Agent:


7 Handling and Storage

---

Handling:

No special procedure.

Fire and Explosion Protection:

No special procedure.

Storage:

Not applicable

Conditions for Storage:

Not applicable

Trade Name: GUROFLEX hardened

Data Prepared: 04.03.2003

Page 2 of 3

8 Exposure and Personal Protection


Limit of Inhalation of Aerosol:

---

Personal Protection Equipment:

For handling with chemicals usual precautions must be noted

Body Protection:

No special clothing required.

General Procedures for Protection and Hygiene: On working do not eat, drink and smoke; keep away
from food-stuff.
9 Physical and Chemical Properties
Form:

solid (soft elastic)


blue

Explosion Limit (Vol-%):


Lower:
Upper:

Colour:

n.a.
n.a.

Smell:

nearly odorless

Vapor Pressure (20 C):

n.a.

Density (20 C):

1,11 g/cm

Changing of State
Melting Point:
Boiling Point:

n.a.
> 200 C

Viscosity (20 C):


(immediately after mixing)

6 -7 Pas

Flash Point:

> 200 C

Solubility in Water:

insoluble

Ignition Temperature: > 200 C


n. a.: not applicable
10 Stability and Reactivity
Conditions to Avoid:

No special procedure.

Agents to Avoid:

---

Hazardous Reactions:

none

Hazardous Decomposition: None if properly used.


11 Toxicological Informations
Acute Toxicity:
LD50 (oral, Rat):
LD50 (inhalative, Rat):

No toxical effects are known.


> 10000 mg/kg
---

Experiences at Humans:

If used properly and keeping of the hygienic precautions on working no


unhealthy effects are known.

Sensitiveness:
12 Ecological Informations

---

Information for Elimination:

Does not contain heavy metals or PCB.

Risk for Water:

Do not enter into sewerage system or waters.

Class of Risk for Water:

no risk for water

Trade Name: GUROFLEX MV hardened

Data Prepared: 04.03.2003

Page 3 of 3

13 Disposal Considerations
Recommendation:

Can be deposit together with domestic rubbish an disposed under consideration


of national rules.
Waste disposal code: EAK No. 08 04 04 (hardened resin)
14 Transportation
No restrictions. The product is not dangerous.
15 Regulations
EG-Regulation:

No special mark is necessary.

MAK:

The product is not in the MAK-list.

TRGS 500:
--16 Other Declarations
The information and data presented in this sheet represent our best knowledge of the product, but are
not a guarantee since the conditions of use are not under our direct control.
For further information ask Dipl. Phys. M. zsan.