BTS Configuration
BTS Configuration
5-1
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Default
TC Board Timeslot 0
Occupancyies CIC
Selected
TC Board Timeslot 1
Occupancyies CIC
Selected
TC Board Timeslot 16
Occupancyies CIC
Selected
TC Board Timeslot 31
Occupancyies CIC
Selected
Auto Calculation
Selected
Description
"TC Board Timeslot 0 Occupyies CIC" and "Reserve" can be selected
alternatively. When the former is selected, the Default "Reserve" is
unavailable.
"TC Board Timeslot 1 Occupyies CIC" and "Reserve" can be selected
alternatively. When the former is selected, the Default "Reserve" is
unavailable.
"TC Board Timeslot 16 Occupyies CIC" and "Reserve" can be selected
alternatively. When the former is selected, the Default "Reserve" is
unavailable.
"TC Board Timeslot 31 Occupyies CIC" and "Reserve" can be selected
alternatively. When the former is selected, the Default "Reserve" is
unavailable.
If "Auto Calculation" is selected, it indicates that the system
automatically calculates the corresponding relationship between CICs
and the trunk circuits of all FTCs.
If "Auto Calculation" is deselected, and "Auto-Calculate Circuit
Property" is selected in the [Basic Information] tab page of the [Set
FTC Board Property] interface during FTC property configuration, the
designated board will automatically calculate circuit property.
Suppose that "TC Board Timeslot 0 Occupyies CIC" and "Auto Calculation" are
selected. Then click <OK> to continue. In the [Hardware] tab page, double click the
FTC configured in Slot2 of Frame4, to pop up the [Set FTC Board Property]
interface, as shown in Figure 5-4.
5-2
Initial Configuration
M900/M1800 BSC Data Configuration Manual
5-3
Initial Configuration
M900/M1800 BSC Data Configuration Manual
If to manually adjust the corresponding relationship between CICs and the trunk
circuits of the designated FTC, please deselect "Auto Calculation" in the [A-Interface
Timeslot Occupancy] tab page. Then double click this FTC and deselect
"Auto-Calculate Circuit Property" in the [Basic Information] tab page of the [Set FTC
Board Property] interface, as shown in Figure 5-5.
5-4
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Note:
If "Auto Calculation" is selected in Figure 5-2, only the start CIC No. of the FTC configured in Slot2 of
Frame4 can be modified. The other CICs are numbered sequentially from the start CIC No.
5-5
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Caution:
The E3M with an even board No. must correspond to the TCSM with an even frame No. Otherwise,
TCSM cannot work normally.
Double click the E3M in Slot2 of Frame3 to pop up the [Set E3M Board Property]
interface, as shown in Figure 5-8.
5-6
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Note:
If there are 2 links in a BM, the 2 links should be connected to 2 LPN7s.
In Figure 5-8, double click a link in the [Signaling Link] list (e.g. link 4) to pop up the
[Signaling Link Property] interface, as shown in Figure 5-9.
5-7
Initial Configuration
M900/M1800 BSC Data Configuration Manual
5.4 BM Data
To describe BM data configuration, here, take "Module [1]" (namely, BM1) as an
example.
I. Full configuration of BM 1
Select "Module [1]" in the [Object List] window of BSC Data Auto Configuration
System. On the right, the [Hardware] tab page will be displayed.
The full configuration of BM1 is shown in Figure 5-10. In this interface, FTC and the
BIE that transparently transmits SS7 signaling need be configured.
5-8
Initial Configuration
M900/M1800 BSC Data Configuration Manual
II. FTC
Double the FTC in Slot2 of Frame4 to pop up the [Set FTC Board Property] interface,
as shown in Figure 5-11.
5-9
Initial Configuration
M900/M1800 BSC Data Configuration Manual
If the circuit state is "Unavailable", it indicates that the circuit is used to transmit
signaling and sync. information. If the state is "Available", it indicates that the circuit
is used for voice and data transmission.
There are 32 circuits in each FTC. The 1st circuit is used to transmit sync.
information. The circuit type is automatically configured as "A/PB Signaling Link",
and the circuit state is "Unavailable".
Because Port0 of the E3M in Figure 5-8 is configured with SS7 signaling, and Slot
16 of the E1 on MSM is used for SS7 signaling transmission, accordingly, Slot16 of
each FTC in this TCSM is unavailable, as shown in Figure 5-12.
5-10
Initial Configuration
M900/M1800 BSC Data Configuration Manual
5-11
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Because this FTC is the first one in BM1, the start CIC No. can be modified. If "Auto
Calculation" is selected in Figure 5-2, the CICs of other FTCs will be automatically
be generated by the system, and cannot be modified.
Generally, "Circuit Availability Indication" should be selected. Otherwise, the circuit
states of the designated FTC will become "Unavailable", and CICs will become
"65535", as shown in Figure 5-15.
5-12
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Voice version
Support full rate voice version 1 and full rate data service (12, 6, 3.6kbit/s).
Support half rate voice version 1 and half rate data service (6, 3.6kbit/s)
Support the voice versions described in circuit pool N0.1 and No.2 above.
Support full rate voice version 2 and full rate data service (12, 6, 3.6kbit/s).
Support the voice versions described in circuit pool N0.1 and No.4 above.
Support the voice versions described in circuit pool N0.4 and No.2 above.
Support the voice versions described in circuit pool No.1, N0.2 and No.4 above.
If 12FTC is in use, select "Circuit Pool 1". If 13FTC is in use and EFR is adopted,
select "Circuit Pool 5". If 13FTC is in use but EFR is not adopted, select "Circuit
Pool 1".
If "Valid for All Circuits" is selected in Figure 5-16, the modifications will be valid for
all trunk circuits.
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Figure 5-18 Configure the BIE that is not used to transparently transmit SS7
Initial Configuration
M900/M1800 BSC Data Configuration Manual
circuit type is BIE. Here, take the full configuration of the BIE frame in BM1 as an
example.
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Frame3 corresponds to the 4 TCSM units of Fame5 in Figure 5-20, i.e., trunk circuits
numbered as 2816~3327 correspond to E3M trunk circuits 512~1023.
E3M trunk circuit numbers are automatically generated by the system, and cannot
be manually modified.
Caution:
Manual adjustment of CIC may lead to abnormal operation of the system. Make ensure that the CIC is
correct.
Each trunk circuit of FTC may correspond to a CIC. CIC must be unique, and should
be determined based on negotiation with MSC.
The 5.2 Relationship between CICs and Trunk Circuits subsection has described
how the corresponding relationship between CICs and trunk circuits is automatically
generated by the system or is manually adjusted. This part will focus on how to
manually modify the corresponding relationship between CICs and FTC trunk
circuits.
Deselect "Auto Calculation" in the [A-Interface Timeslot Occupancy] tab page as
shown in Figure 5-2. Then double click an FTC to pop up the [Set FTC Board
Property] interface, and select the [Basic Information] tab page, as shown in
Figure 5-22.
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Deselect "Auto-Calculate Circuit Property", and then select the [Circuit Property] tab
page, as shown in Figure 5-23.
5-18
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6.1.1 Select BM
In the [Object List] window of the initial data configuration interface, BSC Data Auto
Configuration System, select the BM for which sites are to be added. In Figure 6-1,
BMs are listed as Module [0] to Module [3]. Select Module [3] for site addition,
as shown in Figure 6-1.
6-1
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Note:
The selected BIE must be an active BIE, and not the one that transparently transmits SS7.
6-2
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-3
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Select the first port and click <Add a Site>. The interface will pop up, as shown in
Figure 6-5.
6-4
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Note:
If a site is deleted, all the cells and TRXs of this site will be deleted. If any, the cascaded sites
connected to this site will also be deleted.
6-5
Initial Configuration
M900/M1800 BSC Data Configuration Manual
In BSC Data Auto Configuration System, select "Site0" of "Module [3]" in the [Object
list] window, and then select the [Site Device] tab page in the right window, as
shown in Figure 6-8.
6-6
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-7
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-8
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-9
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Default
Yes
Clock Mode
Clock Parameter 1
Clock Parameter 2
Clock Parameter 3
Alarm Voltage Definition 1
Alarm Voltage Definition 2
Alarm Voltage Definition 3
Transmission Mode
Terrestrial Transmission
Not selected
Description
For BTS30, BTS312 and BTS3012, the Default is
"Yes". For other types of BTS, the Default is "No".
None
None
None
None
None
None
None
The transmission mode of Abis Interface. If the Abis
interface use satellite to transfer data, select
"Satellite Transmission"
For BTS20, this parameter should be selected if the
combiner and divider are adopted, and should not
be selected if CDU is adopted.
Reference:
"Site
Description
Table"
in
M900/M1800
Reference--Engineering Parameters
6-10
BSC
Data
Configuration
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-11
Initial Configuration
M900/M1800 BSC Data Configuration Manual
6-12
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Reference:
"Site Description Table" in M900/M1800 Base Station Controller Data Configuration
Reference - Engineering Parameters
6-13
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Initial Configuration
M900/M1800 BSC Data Configuration Manual
[Basic Cabinet Group Outlet Port] is to specify the E1 port No. of TMU in the basic
cabinet of the basic cabinet group. For the master TMU, the value range is 0~3. For
the slave TMU, the value range is 4~7.
[Extension Cabinet Group Inlet Port] is to specify the E1 port No. of TMU in the
basic cabinet of the extension cabinet group, and the value range is 8~11.
Set the two parameters properly based on the site interior cascade relations. Then
click [OK] to complete the configuration.
So far, all the hardware data of this site have been configured.
6-15
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Caution:
Click <OK>, i.e., after saving a site template, to return to the [Site Device] tab page shown in
Figure 6-8, and press <F11> again to change <Save as Default> into unusable state, to prevent others
from modifying the site template.
6-16
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Note:
If the number of TRXs connected with a port exceed 6, the chain networking mode should be adopted.
Note:
In BTS networking data configuration, the two steps "Select BM" and "Select BIE" are omited.
7-1
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-2
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-3
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7.1.3 6E1Port*2TRX/Port
When "6E1Port*2TRX/Port (supporting star cascade)" is adopted for networking, the
configuration procedure is the same as that described in 7.1.2 4E1 Port*6TRX/Port.
The only difference is that the number of TRXs supported by each port is decreased
to 2 and the number of ports is increased to 6.
7-4
Initial Configuration
M900/M1800 BSC Data Configuration Manual
The data configuration procedure for each networking mode is basically the same.
To describe single chain and multi-chain networking configurations, here, take
"2E1Port*Full-Rate 64K LAPD/Port" as an example.
7-5
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-6
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-7
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-8
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Select [Site Type] as "BTS312" and click <OK>. The newly added Site0 will be
displayed in the [BIE Port Networking Property] tab page, as shown in Figure 7-16.
7-9
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-10
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-11
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Select "Site0" and click <Add a Site>, to create a cascaded site under this site. The
system pops up an [Add Site] interface, as shown in Figure 7-22.
7-12
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-13
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Chain for the configuration procedure. Figure 7-27 shows the result of single chain
networking configuration.
7-14
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-15
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7-16
Initial Configuration
M900/M1800 BSC Data Configuration Manual
Initial Configuration
M900/M1800 BSC Data Configuration Manual
When different types of BTSs, e.g. BTS22C and BTS30, are configured on the same
chain, it is need to adjust manually timeslots.
1)
2)
3)
Press <Shift+F12> in the [BIE Port Networking Property] tab page as shown in
Figure 7-32. The [Manual Mode] check box, the <Site RC Property> button and
<BIE Port Property> buttons will be displayed, as shown in Figure 7-34.
4)
Select "Manual Mode". <Site RC Property> and <BIE Port Property> become
usable, as shown in Figure 7-35.
7-18
Initial Configuration
M900/M1800 BSC Data Configuration Manual
5)
Select "Site0" and click <Site RC Property>. The system pops up an interface,
as shown in Figure 7-36.
7-19
Initial Configuration
M900/M1800 BSC Data Configuration Manual
In the [TRX Property] interface, the user can manually adjust the resources
occupied by all the TRXs of site0, by modifying the values of [Abis TS No.], [Abis
Sub-TS No.], [Trunk Circuit No.], [OML Trunk Circuit No.], [OML Abis TS No.], and
[Idle Timeslot Number]. But the value of [OML Physical Link No.] can not be
modified.
The configuration of idle timeslots is shown in Figure 7-37.
6)
In Figure 7-35, click <BIE Port Property>. The system pops up an interface, as
shown in Figure 7-38.
7-20
Initial Configuration
M900/M1800 BSC Data Configuration Manual
7)
7-21