0% found this document useful (0 votes)
983 views52 pages

Tevi Si Fitinguri Din Fonta Ductila de La DN 60 La DN 2000 Conform en 545-2010 (En)

tevi si fitinguri din fonta

Uploaded by

Gabi Cristache
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
983 views52 pages

Tevi Si Fitinguri Din Fonta Ductila de La DN 60 La DN 2000 Conform en 545-2010 (En)

tevi si fitinguri din fonta

Uploaded by

Gabi Cristache
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

Drinking water supply,

raw water and irrigation

Ductile iron Pipes


and Fittings range

DN 60 to 2000

NEW 2012 EDITION


EN 545: 2010
ISO 2531: 2009
New pressure classes
New Express collars

Comprehensive pipe systems

Welcome new ductile


iron pipes Standards!
What are the new Standards?
EN545:2010 is the European Standard used within the European countries and
ISO2531:2009 is the International Standard used for the international trade for ductile
iron pipes, ttings and joints for water supply.

The best of international expertise!


These 2 new Standards have been developed with a broad participation of water
supply experts of all stakeholders from many countries: Australia, Austria, Belgium,
China, France, Germany, India, Italy, Japan, Korea, Spain, Switzerland,
United Kingdom and the United States.

The most independent Standards


Approved after European consultations for EN 545:2010 under
the authority of European Committee for Standardization (CEN,
31 members countries) and international consultations for
ISO 2531:2009 under the authority of International Organization
for Standardization (ISO, 162 members countries), these
2 new Standards provide technological, economic
and societal benets.

EN545:2010 Standard is on sale online


at the following web sites:
U  ",\www.afnor.org
U -\www.bsigroup.com
ISO2531: 2009 Standard is on sale online at the following web site:
U -"\www.iso.ch

Pressure classes C and disappearance of thickness classes


Material in contact with drinking water
Sustainable development
Quality management
i`iv>Vi

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 1

Drinking water supply, raw water and irrigation

NEW STANDARDS EN 545 & ISO 2531


P 02 .......................................

CHANGES AND ADVANTAGES

COMMITMENT TO THE WATER MARKET


P 04 .......................................

SAINT-GOBAIN PAM

P 06 .......................................

PAM SOLUTIONS

TECHNICAL SPECIFICATIONS
P 10 .......................................

THE MECHANICAL PROPERTIES OF DUCTILE IRON

P 14 .......................................

A COMPLETE RANGE OF ANCHORED OR NON-ANCHORED JOINTS

P 21 .......................................

AN EXTENSIVE RANGE OF EXTERNAL COATINGS

P 24 .......................................

INTERNAL LININGS FOR ALL SITUATIONS

P 25 .......................................

QUALITY, COMPLIANCE

PRODUCTS CATALOGUE
P 35 .......................................

NON ANCHORED PIPE SYSTEMS

P 25 .......................................

ANCHORED PIPE SYSTEMS

PAM COMMITMENTS AND SERVICES


P 35 .......................................

COMMITMENTS

P 25 .......................................

SERVICES

For flanged pipes and fittings from diameter 40 to 2000 (PN 10 to 40), please refer to the relevant documentation
The drawings, illustrations and weights given in this brochure are non-contractual.
SAINT-GOBAIN PAM reserves the right to change product specifications as a result of product improvements without prior notice.

| Drinking water supply, raw water and irrigation

| DN 60 - 2000

| 2012

| The new Standards EN 545: 2010 and ISO 2531: 2009 changes |

Preferred pressure classes

C40

C30

DN 40
to DN 300

DN 350

C25

to DN 600

DN 700
to DN 2000

40 bar *

25 bar *

30 bar *

* allowable operating pressure (PFA)

PRESSURE CLASSES
h Simple organization in pressure classes for pipes and ttings
h Preferred pressure classes for standard installations
h Additional pressure classes for specic requirements
up to 100 bar
h End of thickness classes (K9, etc.)

MATERIAL IN CONTACT WITH DRINKING WATER


h The water used in the mortar mix for the internal lining shall
comply with Drinking Water Directive 98/83/EC
(EN 545 clause 4.5.3.1)
h The pipeline systems have to be in compliance with national
regulations covering materials in contact with drinking water

SUSTAINABLE DEVELOPMENT
Environment
Viable

Bearab
ble

Sustainable
Social
i l

Equitable

Economic

h Approximately 20% reduction in the environmental footprint


of products
h Increased durability via recommendation of elds of use
and a wide choice of protective external coatings
h External zinc coating shall not be less than 200g/m2
(EN 545 clause 4.5.2.2)

QUALITY MANAGEMENT
h Conformity of pipes, joints and accessories must be
demonstrated by performance tests and factory production
control (EN 545 clause 9.1)
h Recommendation to have a quality management system in
compliance with the ISO 9001:2008 Standard
h EN 545:2010 becomes a Standard system by integrating
couplings, anged adaptors and pipe saddles manufactured
for use with ductile iron pipes and ttings (clause 5 and 7)

PERFORMANCES
h The new Standards denes the need to ensure that
components from different suppliers meet the demanding
performance requirements of clause 5 and 7 (ISO 2531)

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 3

| The new Standards EN 545: 2010 and ISO 2531: 2009 changes |

PRESSURE CLASSES
h A clearer offer
h Solutions for very high pressures, up to 100 bar
h Calculation method of internal pressure resistance dened in
the Standard
h Simple and homogenous correspondence between diameter
and allowable operating pressure (PFA)

MATERIAL IN CONTACT WITH DRINKING WATER


h Assurance of high quality drinking water
h Guarantee of compliance with national legislations or
regulations

SUSTAINABLE DEVELOPMENT
h Savings on materials and energy
h Long term reliability of water networks,
for lifetimes of over 100 years
h Increased durability

QUALITY MANAGEMENT
h High quality certied
h Undeniable proof of compliance
h The highest safety level on the market

PFA safety factor


Standard

Ductile iron

PVC

PE

3.00

2.00

1.25

Steel*
~
2

EN 545

EN 1452

EN 12201

EN 10214

* Steel pipes are designed on elastic limit, other materials


on mechanical strength

PERFORMANCES
h Guarantee of a more efcient system
h Added assurance for leak free joint performance

| Drinking water supply, raw water and irrigation

Saint-Gobain PAM

| DN 60 - 2000

| 2012

SAINT-GOBAIN PAM: TIME PROVEN KNOW-HOW


The forerunner of SAINT-GOBAIN PAM company
founded the business in 1856 and has designed
and produced iron pipes from that time onwards,
a product which underwent improvements
in the subsequent years. Pipe spinning allowed
pipes to be produced with more uniform
shapes and thickness and then the introduction of the
ductile iron process on an industrial scale opened up
new technical horizons; this is a new material with
outstanding properties.

Project analysis for proposing SOLUTIONS


As world leader in the manufacture of potable water
supply and distribution pipes, SAINT-GOBAIN PAM has
developed expertise in hydraulics, foundry work and
metallurgy which have established its reputation.
Over the course of years, the true added value of
SAINT-GOBAIN PAM has been manifested in its ability
to define the context of a project and in company with
the designer, seek the most suitable project solution.
A multidiscipline team of engineers, technicians,
experts and others, provide technical support in design
(hydraulic or mechanical calculations, water analyses,
soil surveys, etc.), assistance on site or after-sales
service.

The most resistant systems available on the


market
Cast irons, with a long history of water supply, can take
pride in their record longevity after the passage of
centuries.
Once they have coped with sometimes harsh site
conditions, pressure pipes, will have a long life when
buried which could be subject to various hazards,
due to either the operating conditions or the
environment, such as overpressure, water hammer,
ground movement, or pipe bed destabilisation.
Selection of a pipe with a high safety factor and
mechanical aptitude offers a guarantee of long
investment life and service continuity.
The mechanical properties of ductile iron, combined
with flexible rubber gasket joints, have resulted in
the development of robust, flexible pipe systems,
capable of withstanding the operating conditions
or adverse site conditions without damage. Ductile
iron pipes now constitute the best engineered offer
on the market of the medium-and large-diameter.

Drinking water supply, raw water and irrigation

Systems tailored to their circumstances


Based on a huge databank of references gathered
from all the continents, SAINT-GOBAIN PAMs
researches have culminated in the development of
coatings internal for adaptation to the fluid carried
and external for adaptation to the types of soils
traversed. The pipes have become all soils pipes.
A wide choice of connections, push-in joints,
mechanical joints, anchored or not, permits
adaptation to ground configurations or various
laying circumstances.
Resistant and perfectly leaktight, available from the
smallest to the largest diameters, SAINT-GOBAIN PAM
pipeline systems are synonymous everywhere with
adaptability and safety.

1,000 cities - 100 capitals


A worldwide vocation
In many regions of the globe, the water
resources of a country are still an augury of its
chances of development. Since the beginning
of the 20th century, SAINT-GOBAIN PAM has
exported its products, taking into account the
needs and constraints of its customers both in
Europe and farther.
For water supply alone, SAINT-GOBAIN PAM can
reckon on more than 10,000 items of pipes,
fittings and joint components, to cope with all
situations encountered.
Some 1,000 cities throughout the world, including
more than a hundred capital cities, are equipped
with a SAINT-GOBAIN PAM ductile iron potable
water network.
Everywhere in the world, SAINT-GOBAIN PAM works
in partnership with the people responsible for
the hydraulic infrastructures.

DN 60 - 2000

| 2012 | 5

Saint-Gobain PAM

Prime asset laying of socket joint pipe systems


Consisting of pipes, fittings and gaskets, ductile
iron pipeline systems form a coherent, modular
whole enabling all situations to be coped with.
Socket joint pipes are noted for ease of laying in
progression with simple site tools, without needing
specialised personnel, or site operations like welding
or cathodic protection.
Their robustness allows less care being devoted to
backfilling and compaction, without sacrificing
their expected life.

QUALITY ASSURANCE AND ENVIRONMENT


ISO 9001 U The quality management system
introduced by PAM has been certied as
complying with EN / ISO 9001 Standard by
the independent third party (Bureau Veritas
Certication). This involves specic internal rules
concerning the design, manufacture and sale of
ductile iron products in accordance with high
quality Standards.
ISO 14001UThe PAMs
environmental
management system
complies with
ISO 14001 Standard.
A ductile iron pipe system is
a 100% recyclable product.

| Drinking water supply, raw water and irrigation

PAM solutions

| 2012

MECHANICAL STRESSING
> External loads
> Undermining and unstable grounds
> Site environments

Ductility of iron:
a pipe spirally machined creating
a tough and fully elastic spring

| DN 60 - 2000

THE PAM SOLUTION


A comprehensive ductile iron pipe system

Ductile iron, obtained by a special magnesium


treatment, has an elastic behaviour which confers
outstanding mechanical properties upon the metal.
Impact resistance: ductile iron is tough.
Bending resistance: ductile iron has a considerable elongation capacity (>10%)* and an elastic limit > 270 MPa.
Ovalisation resistance: rigid, ductile iron pipes
deform very little.
All water supply castings, pipes and fittings, are
made of ductile iron and benefit from its outstanding
mechanical properties.
Being extremely tough and robust, they can
withstand high external loading and changes in their
environment without damage: ie, ground movements,
pipe undermining, bedding destabilisation, without
fracturing, cracking or disjointing.

*see page 10.

OPERATING STRESSES
> High pressures
> Exceptional regimes

THE PAM SOLUTION


A system with a high safety factor

Above and beyond the mechanical properties of


ductile iron, SAINT-GOBAIN PAM Standard pipes
are designed to have a large safety reserve well in
excess of that required in service.
They are thus able to withstand, not only high
continuous service regimes, but also any overpressures and water hammer, without deterioration
or effect on the life of the installation.
The PFA of ductile iron pipes is designed with a
safety factor of 3 (ISO 2531, Annex F).

Drinking water supply, raw water and irrigation

PIPELINE LEAKTIGHTNESS UNDER PRESSURE


> Absence of leaks
> Protection of drinking water conveyed
> Reliability and continuity of service

C O AT I N G O N S O C K E T A N D S P I G O T

Rich zinc paint


Varnish (120 m)

Ductile iron

DN 60 - 2000

| 2012 | 7

PAM solutions

THE PAM SOLUTION


Push-in pipes and elastomer gaskets

Ductile iron pipes are installed as works progress,


without welding, simply using standard site tools.
The joints are socket and spigot joints with
elastomer gasket inserted between the two
elements. The gaskets are subjected to severe type
tests, and not only confer the utmost modularity
on the system but very good operational
reliability
by
guaranteeing
leaktightness
of the joint.
Leaktightness is achieved by compressing the
gasket between two metal components: the contact
pressure increases as the internal pressure increases.

INTERNAL LINING
Cement mortar

Ductile iron

E X T E R N A L C O AT I N G

Metallic zinc (200 g/m2)


Varnish (120 m)

FLEXIBILITY OF ELASTOMER GASKETS


> Ground problems and negociating obstacles
> Mechanical strength and flexible chains
> EN 681.1, ISO 4633.

THE PAM SOLUTION


A complete range of joints

Studies by SAINT-GOBAIN PAM show that the


performance of the gaskets depends on a
combination of the rubber hardness, the gasket
shape, and the degree of compression.
Elastomer gaskets accommodate significant
angular deflection and admit radial
displacement under shear loads. These
characteristics provide the adaptability of
the system which operates like a flexible chain
enabling it to follow the curvature of the pipeline,
turn around obstacles, and cope with ground
problems or environment changes.
Through accumulating experience, SAINT-GOBAIN PAM
has developed a complete range of joints able to
cope with all site configurations:
- Push-in or mechanical joints can be self-anchored
by locking systems, which are very simple to use
if site conditions dictate or if concrete anchor
blocks cannot to be used.
- They allow the majority of zones to be crossed,
even with constraints like steep slopes, rocky
areas, laying below the water table and river
crossings.

| Drinking water supply, raw water and irrigation

PAM solutions

| DN 60 - 2000

| 2012

ADAPTABILITY AND DURABILITY


> External coating performances
> TT coatings, for very agresssive soils
> Protection against ageing

THE PAM RESPONSE


A complete range of external coatings

Culminating from SAINT-GOBAIN PAM research


work, the basic external coating of metallic zinc
(200 g/m2) + bitumen finishing coat provides pipe
protection through galvanic action. Experience
shows it is perfectly suitable for the majority of
soils.
If soil surveys confirm significant corrosivity,
SAINT-GOBAIN PAM has designed a range
of coatings dedicated for corrosive soils or special
applications, known as TT Tous Terrains (all soils).

DRINKING WATER PROTECTION


> Internal lining performances
> Durability of installations
> Compatibility with drinking water

THE PAM SOLUTION


Appropriate internal linings

The standard smooth sound internal protection is a


cement mortar applied by a centrifugal process. Being
low in roughness, this lining favours flow, limits head
loss and protects the water from metal contact.
If the presence of agressive or soft waters is known
or to be feared, SAINT-GOBAIN PAM recommends
a passive polyurethane lining which is better suited
to these conditions than the cement mortar. Fittings
with special coatings complete the range.
Chemical analysis of the water will confirm the
recommendation.
All materials coming into contact with drinking water
comply with the most demanding existing regulations.
(See Drinking water compatibility on p25)

SYSTEMS EASY TO LIVE WITH


> Modularity
> Easy laying of socket joint systems
> Operational durability

THE PAM SOLUTION


Compatible and homogeneous ranges

Pipes, fittings or joints: SAINT-GOBAIN PAM offers


a wide range of products, coating and lining
combinations so that customers can benefit from
ductile irons excellent properties of simplicity and
longevity, whatever the site requirements.
The pipe length, ease of assembly, by simple push-in
action, and the possibility of self-anchoring allow
leaktight reliable systems to be constructed without
a specialised team, which stand the test of time.
This guarantees non-premature renewal of hydraulic
infrastructures.

Drinking water supply, raw water and irrigation

DESIGN ASSISTANCE - ADVICE


> Pre-sales studies
> Engineering aid tools and software
at clients disposal
> Sales follow-up

DN 60 - 2000

| 2012 | 9

PAM solutions

THE PAM SOLUTION


Proximity and assistance

SAINT-GOBAIN PAM is committed to provide


solutions, following projects from their design and
to find the most suitable solution within the context
and then supply the best options within the range:
the aim is to provide information and the necessary
tools for designing a reliable durable project.
In order to serve its customers with better service,
SAINT GOBAIN PAM has local extensive sales
network, with the full support of technical and
administrative staff to ensure precise and effective
follow-up on projects.
The After-Sales Service is based on a multi-disciplinary
team able to make rapid and appropriate
interventions.

QUALITY AND RELIABILITY


> Quality Assurance System
> Conformity with Standards
>
Brand

THE PAM SOLUTION


SAINT-GOBAIN PAM pipe systems are manufactured
within organisations complying with EN ISO 9001
certification.
The system products - pipes and fittings - are subjected
to individual pressure tests, and comply with the
French, European and International standards in force.
Choosing SAINT-GOBAIN PAM ductile iron pipe
systems, means choosing quality and reliability for
your equipment.

| Drinking water supply, raw water and irrigation

10

| DN 60 - 2000

| 2012

The mechanical properties of ductile iron

THE MECHANICAL PROPERTIES OF DUCTILE IRON


A new material

Mechanical and environmental stresses

The term cast iron covers a multitude of Fe-C-Si


alloys, classified, amongst other things, according
to the shape of the graphite.
Grey (flake graphite) iron is rendered brittle by the
presence of the graphite flakes which were also
crack initiation points.
By introducing magnesium to the alloy, the graphite
precipitates in a spherical form: the discovery of
ductile (elastic) iron or spheroidal graphite iron
drastically changed the life of cast irons.

Ductile iron pipelines have the advantage of


behaviour wich is intermediate between flexible
and rigid materials. This allows them to benefit
mechanically from the advantages of the two.
Buried pipes can be subject in course of time and
in unstable grounds, for example, to differential
ground settlement, or to undermining by circulating
water wich destabilises the pipe bed.
The elasticity of ductile iron allows the pipelines to
absorb the inevitable stresses or changes undergone
by the immediate surround without breaking or
disjointing.
Buried pipes are also mechanically stressed by
vertical loads, due to the backfill or traffic, liable
to deform the pipes.
It is important therefore to choose a pipe with an
adequate safety factor to avoid such breakage,
fissuring, bending or ovality problems resulting in
high on-costs for the community.

Twisting of a ductile iron bar

Ductile iron characteristics


Elasticity = Re * 270 MPa
Tensile strength = Rm * 420 MPa
Elongation > 10% for pipes DN 60 to 1000
at break
> 7% for pipes DN 1100 to 2000
In the old grey cast iron,
the carbon was present in flake
form thus rendering the
material brittle.

Example of undermining

In ductile iron, the graphite


particles appear as small spheres
eliminating any risk of crack
propagation lines.
The material is no longer brittle.
It is ductile and resistant.

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 11

The mechanical properties of ductile iron

Performance in unstable ground and longitudinal


bending
Buried pipes can sustain significant longitudinal
bending stresses, particularly if the pipes are laid on
a poor quality bed or if the soils have a poor quality
bearing capacity:
- The pipe bed has been destabilised or even undermined, by water table movements,
- The pipeline runs through areas subject to ground
movement and/or earthquakes.
The mechanical behaviour of buried pipes can be
understood by consideration of the pipe-soil sytem.
Ductile iron pipes can withstand significant
deformation without failure, due to the large
elongation capacity possessed by the metal. Tests
carried out have demonstrated that they can sustain
significant deformation without breaking.
The combination of 6-metre ductile iron pipe length
and deflectable elastomer gasket joints allows a
steady take-up of mechanical stresses, and provides
an excellent performance in unstable soils.

| Drinking water supply, raw water and irrigation

12

| DN 60 - 2000

| 2012

The mechanical properties of ductile iron

Loads on buried pipes and ring stiffness

Safe and economic laying


The vertical loads to which the pipes are subjected are
transmitted into the ground through the pipe bedding and
surround.
Large forces come into play and there is an interaction
between the pipe and the ground.
Generally, in order to play their part, the soil layers must be
selected and compacted in accordance with:
- The ability of the pipeline to withstand the local
forces: damage or puncturing that could initiate
cracks or create defects in the pipe wall;
- The pipe stiffness and strength.
The robustness and strength of ductile iron mains allows
the bed preparation and surround to be limited to a strict
minimum thus rendering laying safer and more economic.

External loads arise principally through


the backfill over the pipe or soil loads
(permanent
loads)
and
through
intermittent loads or traffic loads.
Site constraints can impose shallow or
deep depth of cover and the environment
can expose the pipe to repeated traffic
loads. It is important therefore to choose
a pipe material with sufficient mechanical
strength, to avoid failures and service
breakdowns.

Depths of cover: range of possibilities


Depths of cover are established with the following assumptions:
- The pipe strength and deformation criteria comply
with European Standard EN 545 (wall stress and vertical
deflection (ovality).
- Calculation model conforms with Fascicule 70
(French code of practice).
The table below shows the depths of cover and traffic loads
for four different laying examples.

Pipe bed

Case 1

Case 2

Case 3

Case 4

Flat trench bottom

Flat trench bottom

Selected material

Selected material

Backfill

Not compacted

Es (bar)

<3

10

12

20

60

60

90

90

Es : modulus of reaction of the backfill.

Compacted & controlled

2 : supporting angle.

>`>`ivViU*i>vvV>`
*,  ,
*, --1,

-

C40
n

C30

x x x

{x

C25
x

{ x n

2
3

Some other methods


of calculation might
be used
UAnnex F of EN 5452010 Standard
UThe American
Standard ANSI/
AWWA C 150/A
21.50
Consult us

ivVi

4
5

x
Case 1

Case 2

Case 3

Case 4

For depths of cover lower than 0.80 m or other classes, consult us

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 13

The mechanical properties of ductile iron

Mechanical strength: a high safety margin


confirmed by experience
The excellent mechanical performance of ductile
iron pipelines, when subjected to the various forces
of buried pressure pipes (earth loads, traffic loads,
settlement or small ground movements, accidental
overpressures, etc.), is explained by:
a) The ductility of the material: a large energy
absorption capacity is available, beyond the
elastic limit of the metal, due to the metals
elongation capacity;

PFA = Calculated bursting pressure = 20 x e x Rm


Sf
D x Sf

where PFA is the allowable operating pressure (bar)


e is the minimum thickness of the ductile iron wall (mm)
Rm is the tensile strength of ductile iron (Rm > 420 MPa)
D is the pipes external diameter (mm)
Sf is the safety factor (Sf = 3)

There is therefore a safety factor of 3 existing


between the allowable operating pressure adopted
and the calculated bursting pressure.

b) The flexibility of the joints allows the main


to follow small ground movements without
constraining the pipes;
c) The high safety factor, used in calculating the
wall thicknesses of pipes and fittings. Thus, in
accordance with European Standard EN 545
(Annex A) the allowable operating pressure (PFA)
is calculated in accordance with:

Stress-strain curve of ductile iron


Destructive pressure test on a DN 250 pipe

| Drinking water supply, raw water and irrigation

14

| DN 60 - 2000

| 2012

A complete range of anchored and non anchored joints

COMPLETE RANGE OF ANCHORED OR NON-ANCHORED JOINTS


DN 60 / 300

DN 350 / 600

DN 700 / 1200

DN 1400 / 2000

APPLICATION

PIPES & FITTINGS


STANDARD

FITTINGS
EXPRESS

STANDARD Vi

USUAL
SITUATIONS

EXPRESS Vi
HIGH
PRESSURE

DN 80
UNIVERSAL Vi

DN 1400

DN 100
UNIVERSAL Ve

STANDARD V+i

DN 1800
PAMLOCK

HIGH
HYDRAULIC
THRUST

SUPPLEMENTARY
SELF-ANCHORING

DN 80
STANDARD Ve

JOINT PERFORMANCE
The joint is a key point in a pressure pipeline and
must not be a source of weakness. Well designed
gasket shape and drastic elastomer selection
ensures steady, reliable and durable pipe systems
operation whilst rendering it flexible and easy to
assemble.

Leaktight joints
Ductile iron pipeline components are joined
together by an elastomer gasket providing
connection and leaktightness.
Leaktightness is achieved by compressing the
elastomer gasket between two metallic elements:

- With mechanical joints, axial compression is


applied by means of a gland and bolts,
- With push-on joints the compression is radial.
It is of utmost interest to the user that a pipeline
does not drain external water: ingress of water
from the water table could render the water
conveyed unsuitable for human consumption.
The gaskets used are usually EPDM rubber; they
are selected to keep their physico-chemical
characteristics over time, thus ensuring their
leaktightness function is perpetuated.

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 15

A complete range of anchored and non anchored joints

Flexible joints
The elastomer gaskets provide ductile iron pipelines
with mechanical flexibility, which constitutes an element
of safety when traversing poor consistency or unstable
ground (marshy areas, subsidence due to the abstraction
of underground water, or mining, consolidation of road
hardcores, etc...).
It is advisable to assess the potential for subsidence and
to take all precautions to minimise the effect of soil
movement on the pipeline. Measurements on site are
always recommended.
Experience has shown that when ground movement occurs,
a pipeline must be able to follow the deformation caused,
instead of trying to resist the often considerable mechanical
stresses generated (longitudinal and bending forces).
Socket joints enable the pipeline to act like a flexible chain
within the limits of the allowable axial withdrawal. They
allow large radius curves to be laid without the use of
fittings.
The assemblies which must not reveal any leak, are subjected
to the following performance tests specified in European
Standard EN 545 (which are higher than those specified in
ISO 2531.

Angular defection
Joint
DN

60
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1100
1200
1400
1500
1600
1800
2000

Test

Test requirements

Test conditions

Positive
internal
hydrostatic
pressure

Test pressure:
(1.5 PFA + 5) bar
Test duration: 2 h
No visible leakage

Joint of maximum annulus,


aligned and withdrawn,
with shear load

Negative
internal
pressure

Test pressure : - 0.9 bar*


Test duration: 2 h
Maximum pressure change
during test period: 0.09 bar

Joint of maximum annulus,


aligned, with shear load

Positive
external
hydrostatic
pressure

Test pressure : 2 bar


Test duration: 2 h
No visible leakage

Joint of maximum annulus,


aligned and withdrawn,
with shear load

Cyclic
internal
hydraulic
pressure

24 000 cycles
Test pressure: between
PMA and (PMA - 5) bar
No visible leakage

Joint of maximum annulus,


aligned and withdrawn,
with shear load

Joint of maximum annulus,


deflected

Joint of maximum annulus,


deflected

* 0,9 bar below atmospheric pressure (approximately 0,1 bar absolute pressure)

New
Increased angular deflection
for STANDARD joint

Non Anchored
STANDARD*

EXPRESS *

5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
4
4
4
3
3
3
2.5
2

5
5
5
5
5
4
4
4
3
3
3
3
3
2
2
1.5
1.5
1.5
1.5
3
2
2
1.5
1

Anchored

UNIVERSAL * STANDARD Vi* EXPRESS Vi*

3
3
3
3
3
3
3
3
3
2
2
2
2
2
1
1
-

5
5
5
5
5
4
4
4
3
2
2
2
2
-

4
4
4
4
4
3
3
3
-

UNI Vi Ve Pk*

3
3
3
3
3
3
3
3
3
3
2 (Uni Vi) 3 (Uni Ve)
2
2
2
1.5
1.2
1.1
1
1
1
0.8
-

STANDARD Ve* STANDARD V+i*

5
5
5
5
4
4
4
3
3
3
3
3
2
2
1.5
1.5
1.5
1.5
-

3
3
3
2
2
-

* Maximum angular deflection

| Drinking water supply, raw water and irrigation

16

| DN 60 - 2000

| 2012

A complete range of anchored and non anchored joints

High maximum
pressures

PFA = Allowable operating pressure


Maximum hydrostatic pressure that a component is able to withstand in permanent service.

In compliance with
the European Standard
EN 545: 2010 and
International Standard
ISO 2531: 2009.

PMA = >Li>i>}iiUPMA = 1.2 x PFA


Maximum pressure including water hammer that a component is able to withstand
occasionally during service.
* r>LiiiiU* r*xL>
Maximum hydrostatic pressure that a newly installed component is able to withstand
for a relatively short period to ensure the pipelines integrity and leaktightness.

Non Anchored pipes and fittings


PIPES
DN

(1)
A

Preferred
Pressure PFA(1)
Class

FITTINGS
STANDARD FITTINGS (3)

STANDARD PIPES
PMA(1)

PEA(1) Deflection(2)

Fittings
Class

PFA(1)

PMA(1)

EXPRESS FITTINGS (4)

PEA(1) Deflection(2) PFA(1)

PMA(1)

PEA(1) Deflection(2)

Bar

Bar

Bar

Bar

Bar

Bar

Bar

Bar

Bar

60

C40

40

48

53

C100

64

77

82

64

77

82

80

C40

40

48

53

C100

64

77

82

64

77

82

100

C40

40

48

53

C100

64

77

82

64

77

82

125

C40

40

48

53

C64

64

77

82

64

77

82

150

C40

40

48

53

C64

64

77

82

50

60

65

200

C40

40

48

53

C64

64

77

82

50

60

65

250

C40

40

48

53

C50

50

60

65

50

60

65

300

C40

40

48

53

C50

50

60

65

40

48

53

350

C30

30

36

41

C50

50

60

65

25

30

35

400

C30

30

36

41

C40

40

48

53

25

30

35

450

C30

30

36

41

C40

40

48

53

25

30

35

500

C30

30

36

41

C40

40

48

53

25

30

35

600

C30

30

36

41

C40

40

48

53

25

30

35

700 C25AC30B 25A 30B 30A 36B 35A 41B

C30

30

36

41

25

30

35

800 C25AC30B 25A 30B 30A 36B 35A 41B

C30

30

36

41

25

30

35

900 C25AC30B 25A 30B 30A 36B 35A 41B

C30

30

36

41

25

30

35

1.5

1000 C25AC30B 25A 30B 30A 36B 35A 41B

C30

30

36

41

25

30

35

1.5

1100

C25

25

30

35

C30

30

36

41

25

30

35

1.5

1200

C25

25

30

35

C30

30

36

41

25

30

35

1.5

1400

C25

25

30

35

C30

30

36

41

25

30

35

1500

C25

25

30

35

C25

25

30

35

25

30

35

1600

C25

25

30

35

C25

25

30

35

25

30

35

1800

C25

25

30

35

2.5

C25

25

30

35

2.5

25

30

35

1.5

2000

C25

25

30

35

C25

25

30

35

25

30

35

see page 16

(2)

Maximum angular deflection

: in NATURAL and HYDROCLASS ranges

(3)

: in CLASSIC range

Consult us for Tee above DN 1400 with branch above 600

(4)

in DN1400-2000 EXPRESS collars only

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 17

A complete range of anchored and non anchored joints

Anchored pipes and fittings - DN 60 - 600


DN

Pipe
Class

60
80
100
125
150
200
250
300
350
400
450
500
600

C40
C40
C40
C40
C40
C40
C40
C40
C30
C30
C30
C30
C30

STANDARD Vi

EXPRESS Vi

Pipe
PFA(1) PMA(1) PEA(1) Deflection PFA(1) PMA(1) PEA(1) Deflection Class
Bar

Bar

Bar

Bar

Bar

Bar

22
16
16
16
16
16
16
16
16
16
13
11
10

26
19
19
19
19
19
19
19
19
19
16
13
12

31
24
24
24
24
24
24
24
24
24
21
18
17

5
5
5
5
5
4
4
4
3
2
2
2
2

22
16
16
16
16
16
16
16
-

26
19
19
19
19
19
19
19
-

31
24
24
24
24
24
24
24
-

4
4
4
4
4
3
3
3
-

UNIVERSAL Vi

UNIVERSAL Ve

PFA(1) PMA(1) PEA(1) Deflection PFA(1) PMA(1) PEA(1) Deflection

C100
C100
C64
C64
C64
C50
C50
C40
C40
C40
C40
C40

Bar

Bar

Bar

Bar

Bar

Bar

60
56
52
48
43
39
34
25
20
16
16
16

72
67
62
58
52
47
41
30
24
19
19
19

77
72
67
63
57
52
46
35
29
24
24
24

3
3
3
3
3
3
3
3
3
3
2
2

64
64
60
52
46
40
38
35
32
30
30

77
77
72
62
55
48
46
42
38
36
36

82
82
77
67
60
53
51
47
43
41
41

3
3
3
3
3
3
3
3
3
3
2

Anchored pipes and fittings - DN 700 - 2000


UNIVERSAL Ve

(1)

PAMLOCK

DN

Pipe Class

PFA(1)
Bar

PMA(1)
Bar

PEA(1)
Bar

Deflection(2)

PFA(1)
Bar

PMA(1)
Bar

PEA(1)
Bar

Deflection(2)

700
800
900
1000
1200
1400
1500
1600
1800
2000

C30
C30
C30
C30
C25A C30B
C25
C25
C25
C25
C25

27
25
25
25
20A/25B
-

32
30
30
30
24A/30B
-

37
35
35
35
29A/30B
-

2
2
1,5
1,2
1,1
-

25
25
25
16

30
30
30
19

35
35
35
24

1
1
1
0,8

see page 16

(2)

Maximum angular deflection

Please consult us

: in NATURAL and HYDROCLASS ranges

: in CLASSIC range

Anchored Pipes and fittings - Supplementary solutions


STANDARD Ve

(1)
A

DN

Pipe Class

PFA(1)
Bar

PMA(1)
Bar

PEA(1)
Bar

80
100
125
150
200
250
300
350
400
450
500
600
700 (3)
800 (4)
900 (4)
1000 (4)
1100
1200

C100
C100
C64
C64
C64
C50
C40
C30
C30
C30
C30
C30
C25
C25
C25
C25
C25
C25

64
64
64
55
46
35
28
27
25
23
22
20
20
16A 20B
16A 20B
16A 20B
16A 20B
16A 20B

77
77
77
66
55
42
34
32
30
28
26
24
24
19A 24B
19A 24B
19A 24B
19A 24B
19A 24B

82
82
82
71
60
47
39
37
35
33
31
29
29
24A 29B
24A 29B
24A 29B
24A 29B
24A 29B

see page 16

(2)

Maximum angular deflection

: with ductile iron bolts and nuts

(3)

STANDARD V+i
Deflection(2) Pipe Class

5
5
5
5
4
4
4
3
3
3
3
3
2
2
1.5
1.5
1.5
1.5

DN 700 : PFA 25 bar with ductile iron bolts

: with steel bolts and nuts and socket, PFA 25 bar with C30 pipes

C40
C40
C40
C40
C40
(4)

PFA(1)
Bar

25
20
16
16
16
-

PMA*
Bar

30
24
19
19
19
-

(1)

PEA(1)
Bar

Deflection(2)

35
29
24
24
24
-

3
3
3
2
2
-

DN 800 to 1000, PFA 25 bar with steel bolts and C30 pipes
STANDARD V+i : to use only on Universal pipe spigot C40.
Do use use on C30 spigots

| Drinking water supply, raw water and irrigation

18

| DN 60 - 2000

| 2012

A complete range of anchored and non anchored joints

U-/ , vi>`v}
The STANDARD joint is a push-on joint.
Leaktightness is achieved by compressing an
elastomer gasket, which is situated in the socket
internal seat, and is subjected to radial compression
when the spigot of the next pipe is pushed into
place.
- Highly reliable under low or high pressure: the contact
pressure between the elastomer and the ductile
iron increases as the internal pressure increases: the
STANDARD gasket is subject to a servo effect.
During a destructive pressure test, the pipe bursts,
with no leakage detected at the joint.

STANDARD Joint
for pipes and fittings

- Flexibility: significant angular deflection can


be accepted and significant axial withdrawal.
Recommended for unstable ground and the
negociation of obstacles.
- Electric discontinuity.
U 8*, --vv}
The EXPRESS joint is a mechanical joint.
Easy to install without any push-in force.
Leaktightness is provided by axial compression of
an elastomer gasket, by tightening a gland with
iron bolts.
EXPRESS joint for fittings

USTANDARD Vi and EXPRESS Vi anchoring


solutions for usual situations
In 1994, the launching of STANDARD Vi and
EXPRESS Vi with anchoring inserts in the gasket
was a significant progress. Now STANDARD Vi is
available up to DN 600.

UA new application:
horizontal Directional Drilling (HDD)
Horizontal directional drilling is a pipe laying technique
for new installations without trench digging or
disturbances of surface activities. It is particularly
recommended for passing under roads, motorways,
roundabouts, railway lines, pedestrian or built-up areas.
The exceptional mechanical and bending strength mean
SAINT-GOBAIN PAM ductile iron pipes can be prescribed
for trenchless installations, in diameters up to DN 1000,
that is, well in excess of those used up to the present.
ISO 13 470 Standard gives specifications for trenchless
applications of ductile iron pipe systems.

New
STANDARD Vi is available
up to DN 600

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 19

A complete range of anchored and non anchored joints

ANCHORING SOLUTIONS
for high pressure pipe systems
All pipe systems carrying a fluid under pressure are
subjected to significant stresses: thrust forces occur
at changes in direction, reductions in diameter and
at the ends of pipelines. It is essential to counterbalance these forces to prevent any risk of disjointing
either by the use of concrete anchor blocks, or selfanchoring the pipe system.

UNIVERSAL double chamber pipe where the


chambers house leaktightness and anchoring
functions separately: a traditional STANDARD
gasket in the second chamber, and a new rubber
anchoring gasket equipped with metallic inserts
in the first chamber (UNIVERSAL Vi anchoring
gasket) or a ductile iron ring (UNIVERSAL Ve).

U>V}\i1 6 ,->`*"

solution for DN 80 to DN 1800
For many years, alternative solutions to concrete
anchor blocks have existed for anchoring ductile
iron pipes in the ground, but they were rarely used
because they relied on the application of a weld
bead on site.
SAINT-GOBAIN PAM now offers an anchoring system
for higher pressure rating with a specific range of
pipe and fittings called UNIVERSAL.
The UNIVERSAL range fulfills the requirements
of European Standard EN 545 and ISO 2531 and
ISO 10 804-1 (specific type test for anchor joints.

UNIVERSAL Vi joint for pipes or fittings

The PAMLOCK range also allows self-anchoring of


large diameter pipelines (DN 1400 to DN 1800).

New
UNIVERSAL Ve is available
from DN 100 to DN 1200

The PAMLOCK range consists of double chamber


pipes: a works applied weld bead, and a ring made
up of several segments held together by elastomer
connectors.

New
UNIVERSAL Vi is available
from DN 80 to DN 600

A conformator designed to transmit the axial force


to the internal socket surface by means of shot
granules which act like a fluid and distribute the
axial forces.

UNIVERSAL Ve joint for pipes or fittings

UNIVERSAL and PAMLOCK are boltless anchoring


systems with leaktightness and anchoring
functions separate.

PAMLOCK joint for pipe or fittings

| Drinking water supply, raw water and irrigation

20

| DN 60 - 2000

| 2012

A complete range of anchored and non anchored joints

OTHER ANCHORING SOLUTIONS


Along with this new type of self-anchored offer,
the usual range of weld bead anchoring system STANDARD Ve pipes and fittings - is still proposed.
Although being a little more complex to install, it
retains specific areas of application, such as very
high pressures, poorly comprehended or controlled
dynamic stresses.

STANDARD Ve pipes or fittings

STANDARD V+i joint for fittings.

Classic STANDARD fitting with a rim: anchoring is


achieved by adding the anchoring gasket, under a
gland, during assembly. Leaktightness is provided
by a traditional elastomer gasket situated in the
fittings socket.

Refer to the Self- Anchoring Solutions for


ductile iron pipes catalogue

Particularly suited to cope with hydraulic forces,


anchoring solutions extend the application field of
ductile iron pipe systems to geological situations
where construction of concrete anchor blocks
would be difficult (underwater laying prior
assembly outside the water, as works progress, with
self-anchored joints poor soil cohesion), costly
or very complicated, such as urban situations with
very congested sub-soils, situations where later
reopening of the ground could jeopardise the
stability of ancillary structures.
They also allow ductile iron pipes to be used
for particular conditions: galleries, steep slopes,
horizontal directional drilling, etc

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 21

An extensive range of external coatings

AN EXTENSIVE RANGE OF EXTERNAL COATINGS


Basic range: durable zinc-sprayed pipes
Buried pipelines are subjected to many stresses,
including corrosivity of soils and backfills. The basic
coating for SAINT-GOBAIN PAM pipes consists of
a layer of metallic zinc (200 g/m2 minimum) spray
applied and covered with a finishing varnish.
This is an active coating suitable for the vast
majority of soils.
Standards: EN 545 and ISO 8179-1.
The zinc coating consists of:
- a layer of 200 g/m2 metallic zinc applied by
spraying,
- a varnish pore sealer: bitumen paint (average
thickness of 100 ) or synthetic varnish.
Zinc metallisation is an active protection
due to the galvanic effect of the zinc/iron
electrochemical couple.
This coating is available on CLASSIC (in black
colour) and HYDROCLASS (in dark blue colour)
ranges.
A coating has been developped by Saint-Gobain
PAM. This coating, called ZINALIUM, consists of :
- a layer of 400 g/m2 Zn/Al 85/15 alloy
- a finishing pore sealer : blue epoxy paint
(average thickness of 100 ) or equivalent.

Its mechanism of protection of zinc and zinc/


aluminium alloy is twofold:
U>v>>LiiVi>i
In contact with the surrounding soil, the metallic
zinc slowly transforms into a dense, adherent,
impermeable and continuous zinc salts. This acts as
a protective barrier.
The pore sealer, whilst permitting galvanic
protection and self-healing, favours the formation
of a stable and insoluble layer of zinc conversion
products.
U-ivi>}v`>>}i
This mechanism occurs first.
One of the particular features of the external zinc
coating is its ability to restore the continuity of the
protective layer where small areas of local damage
exist.
The Zn++ ions migrate through the pore sealer to
plug the damage and then convert into stable,
insoluble zinc corrosion products.
SAINT-GOBAIN PAM has chosen to raise the zinc
quantity to 200 g/m2 (instead of the 130 g/m2
prescribed by the ISO 8179 Standards).
50% of extra zinc ensures a significant increase in
the galvanic protections life span.
For highly aggresives soils refer to next page.

This new coating improves significantly the life


duration and field of use of ductile iron pipes.
This ZINALIUM coating is available on NATURAL
range.

Zinc spray

In experiments carried out at the SAINT-GOBAIN PAM


Research Centre, two identical notches were practised on
samples and then immersed in a highly corrosive medium
Non-zinc coated:

Zinc coated:

The damage worsened and


the corrosion (red marks)
extends beyond the notch

A white line of zinc salts shows


that the damage is perfectly
plugged.

| Drinking water supply, raw water and irrigation

22

| DN 60 - 2000

| 2012

An extensive range of external coatings

Comprehensive range of coatings


for highly agressive soils
In their basic version zinc-coated SAINT-GOBAIN PAM
pipes have an excellent resistance to corrosion which
is satisfactory for the majority of applications.The
corrosivity of soils should nevertheless be assessed
beforehand to see whether special coatings are
needed for extra protection.
In order to guarantee the durability of the networks,
SAINT-GOBAIN PAM offers a full range of special
coatings from DN 80 to DN 2000, for cases of
extremely corrosive areas:
- crossing of sea inlets,
- marsh or peaty areas,
- saline water table,
- polluted or unpredictable soils (industrial waste).

UEasy to lay
All the products in the TT PUX range are available in
anchored or non-anchored versions. Self-anchored
and flanged joints could require special protection.
Please consult us.

T T- P E e x t e r n a l c o a t i n g
C O AT I N G O N S O C K E T A N D S P I G O T

Metallic zinc (200 g/m2)


Bituminous varnish (70 m)

Ductile iron

INTERNAL LINING
Cement mortar

On request SAINT-GOBAIN PAM technical team


will carry out soil surveys to assess their corrosivity
and recommend the most appropriate form of
protection.
For those of your projects laid in highly corrosive
areas, SAINT-GOBAIN PAM offers a complete pipe
system suitable for the conditions:

Ductile iron

E X T E R N A L C O AT I N G

Metallic zinc (200 g/m2)


High density polyethylene (1800 to 2500 m)

T T- P U X e x t e r n a l c o a t i n g
C O AT I N G O N S O C K E T A N D S P I G O T

Red epoxy (250 m)

- DN 80 to 700: TT PE pipes with coextruded


polyethylene coating (in accordance with
EN 14 628);
- DN 100 to 2000: TT PUX pipes with a sprayapplied external polyurethane coating
(in accordance with EN 15 189);
- DN 100 to 2000: STANDARD fittings with internal
and external epoxy coating (fusion bonded,
in accordance with EN 14901) or polyurethane
coating (large diameter in accordance with
EN 15 655).
UGuaranteed integrity
These coatings, known as passive coatings have
excellent chemical inertness and act as a protective
barrier between the ductile iron and the external
environment, completely isolating the material
from the corrosive action of the soil.
Pipe integrity is also ensured for bundling and
transport by means of special protective devices
(straps, caps, etc).

Ductile iron

INTERNAL LINING
Cement mortar

Ductile iron

E X T E R N A L C O AT I N G
Polyurethane (from 700 to 900 m)

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 23

An extensive range of external coatings

ISOPAM preinsulated pipes DN 100 to DN 600


pipes
These are ductile iron pipes equipped with a works
applied heat insulating cladding in accordance with
Standard ISO 9394. They are used to:
Uprevent or delay the risk of freezing of the fluid
conveyed (frost protection):
bridge crossings, above-ground installation
exposed to adverse weather, shallow depths of
cover in cold regions, pumping and outlet pipes
in water towers; or,
Umaintain the fluids temperature as constant
as possible: transport of refrigerated water, for
example.

| Drinking water supply, raw water and irrigation

24

Internal linings

| DN 60 - 2000

| 2012

INTERNAL LININGS FOR ALL SITUATIONS


Sulfate resisting cement mortar lining
The basic internal protection for STANDARD pipes is
a blast furnace cement mortar lining applied by
centrifugal action. This process has the advantage
of producing a sound mortar with a smooth internal
surface.
This results in the following properties:
- High mortar compactness,
- Good bonding to metal,
- Low surface roughness.

Protective mechanism
The cement lining does not act merely as a barrier,
but protects the iron through a passivation
mechanism: during the filling, water gradually soaks
into the mortar and absorbs alkaline compounds; by
the time it reaches the metal wall, it is consequently
non-corrosive.
Crack plugging
Crazing (hydraulic shrinking), or even small cracks
occurring during transport, storage or laying, close
up through the combined effect of two reactions:
- Rapid mortar swelling on exposure to water,
- Slow hydration of the cements constituents.
Special situations
European Directive 98/83/CEE sets out the quality
criteria for waters intended for human consumption.
Whether arising from particular geological context,
resulting from treatments, or being conveyed for
very lengthy periods in pipelines, aggressive or
corrosive waters are a threat to most materials with
which they come into contact (aggressive water has
a lime-carbonic acid imbalance). Corrosive waters
have a low pH (usually below 5.5).

U/iVii>}i>Viv
Cement mortar has a very smooth inner surface,
which enhances flow and reduces head losses. This
mortar guarantees that hydraulic performance is
maintained over time (absence of deposits).
The roughness coefficient (COLEBROOK formula)
for a pipe alone is k = 0.03 mm.
SAINT-GOBAIN PAM recommends using k = 0.1 mm
in practice when designing a pipe system in order
to take any peculiar head losses in the complete
main into account.

When such circumstances are feared or known


to exist, ductile iron pipes may need a passive
lining, such as PUR (polyurethane lining in
accordance with EN 15655) which will allow
the system operator to benefit from all the
properties of ductile iron, even under adverse
conditions.

U/iVii>}iVLi
and drinking water
U*iv>ii}Vii>
lining (either SRC or blast furnace cement lining)
in accordance with Table E.1 column 3 of
EN 545: 2010.
PUR pipes
DN 100 to DN 1000

Drinking water supply, raw water and irrigation

QUALITY

DN 60 - 2000

| 2012 | 25

Quality, compliance

COMPATIBILITY WITH DRINKING WATER

SAINT-GOBAIN PAM quality procedure extends well


beyond the products, and involves the company
from design to delivery.
The SAINT-GOBAIN PAM Quality Assurance system
is based on the ISO 9001 Standard, which certifies
mastery of the manufacturing processes (design,
development, production, installation and associated activities). All works manufacturing products in
the STANDARD range hold this certificate, issued by
a third party.

The materials used by SAINT-GOBAIN PAM, and


in contact with drinking water (cement mortar,
coatings, elastomers, and lubricating pastes), are
covered by a French Health Compliance Certificate
(ACS as well as by the british regulation of the DWI
(Drinking Water Inspectorate), in the UK and other
national regulations for drinking water.
These compliances are certified by independent
organisations.

SAINT-GOBAIN PAM products comply with


European and International Standards (EN and ISO).
Compliance with these Standards is certified by
independent organisations.
These Standards define the product or service in
terms of outcome; every product, pipe or fitting is
individually tested at works, by an internal pressure
test.

COMPLIANCE
Specification

European
Standard

International
Standard

Test methods and requirements

EN 545 (1)

ISO 2531 (1)

Cement mortar lining

EN 545 (1)

ISO 4179 (1)

Pipe external zinc coating

EN 545 (1)

ISO 8179-1 (1)

Pipe external Zn/Al 400g/m2

EN 545 (1)

EN 681-1 (1)

ISO 4633 (1)

Gaskets Materials specification


(1)

Compliance certified by an independant accredited third party

SERVICE AND LOGISTICS


SAINT-GOBAIN PAM provides an on-the spot
service through a team of expert engineers and
technicians from its numerous international locations
and an important network of representatives.
The sales team feed back information used by
product development teams.
Close to their clients, they carry out technical evaluation
and customer assistance assignments, such as, design
consultancy (hydraulic calculations, engineering
calculations, water analyses, soil surveys, etc.), site
assistance, after-sales service, and so on

An international Group, with operations in many


countries around the world, SAINT-GOBAIN PAM
uses its extensive knowledge of logistics and
transport to serve markets the world over.

26

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

Pipe
barrel

Socket

Average
metric

DE
mm

B
mm

Weight
kg / m

Joint

Pipe Class

Nominal Average
diameter working
length
DN
Lu
mm
m

PRODUCTS CATALOGUE

Sealing gasket for


STANDARD pipes and
fittings DN 60 to 2000

Non-anchored Pressure Class


STANDARD socket pipes DN 60 to 2000
DN 60 to 1200

DN
mm

Weight
kg

60

77

144

9.4

60

0.11

80

98

167

12.2

80

0.15

100

118

188

14.9

100

0.20

125

144

215

18.3

125

0.24

150

170

242

22.2

150

0.29

200

222

295

30.2

200

0.38

250

274

352

42.2

250

0.50

300

326

409

55.6

300

0.71

350

378

464

68.8

350

0.90

400

429

516

79.4

400

1.10

450

480

574

93.8

450

1.32

500

532

629

111.2

500

1.54

600

635

738

150.6

600

2.16

700

6.955

738

863

186.2

700

2.87

800

6.950

842

974

229.0

800

3.67

900

6.950

945

1082

276.2

900

4.61

1000

6.955

1048

1191

330.6

1000

5.59

1100

8.190

1151

1300

395.4

1100

7.68

1200

8.185

1255

1412

461.3

1200

9.34

1400

8.170

1462

1592

634.3

1400

15.50

1500

8.160

1565

1710

720.3

1500

19.80

1600

8.160

1668

1816

807.5

1600

21.05

1800

8.150

1875

2032

995.1

1800

27.72

2000

8.130

2082

2259

1210.0

2000

29.00

DN 1400 to 2000

C30

Pipes and fittings DN 60 to 1200

C25

STANDARD

C40

Pipes and fittings DN 1400 to 2000

NB: for other pressure classes, please consult us.

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

27

Non-anchored double socket bends


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
1/4
Weight
kg

Lu
mm

DN

1/8
Lu
mm

1/16
Weight
kg

Lu
mm

1/32

Weight
kg

Lu
mm

Weight
kg

STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP
60
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1100
1200
1400
1500
1600
1800
2000

75 75
91 91
105 102
133 130
152 150
200 200
252 250
304 280
390 390
436 436
482 482
525 525
624 624
670 735 880 1000 -

6.2
7.6
10.0
13.9
18.1
29.2
49.6
72.7
115
141
150
216
311
584
696
800
1461
-

6.4
8.7
6.8
9.0
11.5
18.8
33.5
43.1
95
140
170
215
312
-

76
56
65
83
92
100
139
167
168
189
216
220
283
335
364
403
440
540
537
522
572
563
642
685

76
56
60
65
75
95
115
150
168
189
216
220
283
335
364
403
439
540
537
-

6.5
7
8.9
12.3
15.6
23.7
40.5
59
69
89
118
146
208
311
414
545
703
993
1015
1555
1815
2089
3126
3702

6.7
8.1
6.0
7.6
9.5
14.6
25.9
35.6
72
91
120
155
234
312
417
551
649
993
1033
-

30
32
35
38
42
51
70
90
78
92
100
110
140
157
170
197
217
275
258
264
314
284
337
355

30
32
35
40
45
55
65
75
78
92
100
110
140
157
170
197
217
275
258
-

4.9
6.2
7.8
9.9
12.2
18.9
32.2
42.2
53
69
88
108
144
231
303
406
507
650
644
1107
1367
1479
2070
2668

5.6
7.4
5.4
6.8
8.4
12.5
22
26.8
57
71
92
118
166
232
305
406
459
663
675
-

35
40
40
45
46
52
55
50
53
58
67
71
94
87
90
102
117
140
138
143
193
153
200
200

35
40
30
35
35
40
50
55
53
58
67
71
94
87
90
102
117
140
138
-

5.1
6.5
7.9
10.3
12.6
19.2
30.5
39.7
49
62
80
96
128
196
253
326
414
490
478
884
1143
1173
1542
2151

5.7
7.6
5.3
6.6
8
11.6
20.8
26.6
48.5
64.5
84
106
148
197
255
332
360
589
509
-

STD/EXP - DN 60 to 1200
Lu

Lu

STD - DN 1400 to 2000

8*, --iV>V>>iL / Fittings DN 60 to 1200


DN

60
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1100
1200

Sealing gasket
Weight / kg

Gland
ext / mm

0.04
0.06
0.08
0.12
0.14
0.20
0.25
0.35
0.46
0.52
0.66
0.73
1.05
2.60
3.30
4.20
5.20
6.10
7.40

226
249
270
290
324
364
417
474
529
582
669
725
836
955
1068
1178
1289
1400
1512

Ductile iron bolts


/ mm
Nbr
22
2
22
3
22
3
22
3
22
4
22
5
22
6
22
7
22
8
22
9
27
8
27
10
27
12
27
16
27
18
27
20
27
24
27
26
27
30

Total accessories
Weight / kg
2.8
4.0
4.3
4.5
5.6
7.2
8.8
11.1
12.6
15.0
23.5
28.1
36.5
53.2
64.5
78.0
94.2
114.6
130.1

EXP - DN 60 to 1200
except 80, 100, 150

EXPRESS NEW
DN 80, DN 100, DN 150

28

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Non-anchored double socket tees with flanged branch


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
STANDARD

EXPRESS

Weight with flange

Weight with flange

DN
body

dn
branch

Lu
mm

Hu
mm

PN 10
kg

PN 16
kg

PN 25
kg

PN 40
kg

PN 10
kg

PN 16
kg

PN 25
kg

PN 40
kg

60

40*
60*
40*
60*
65*
80*
40*
60*
65*
80*
100*
40*
60*
65*
80*
100*
125*
40*
60*
65*
80*
100*
125*
150*
40*
60*
65*
80*
100*
125*
150*
200*
60*
65*
80*
100*
150*
200*
250*
60*
65*
80*
100*
150*
200*
250*
300*

154
154
145
145
145
183
150
150
150
185
210
150
150
150
165
190
267
154
154
154
165
190
220
305
159
159
159
170
195
220
250
360
164
164
234
234
251
344
404
237
237
237
237
347
347
467
467

141
161
149
169
174
165
161
181
186
177
180
164
184
189
195
200
200
176
196
201
210
215
210
220
209
229
234
240
245
240
245
260
272
272
250
270
280
290
300
297
297
298
300
310
320
305
340

8.8
9.7
10.2
11.1
11.5
12.5
12.0
12.9
13.3
14.5
16.4
14.3
15.2
15.6
16.8
18.5
23.0
17.1
18.0
18.5
19.6
21.4
23.8
29.5
25.1
26.0
26.5
27.0
29.1
31.6
34.9
44.7
38.9
39.3
43.6
43.4
49.5
60.3
69.6
56.3
56.7
57.4
58.1
71.2
75.7
89.4
97.9

8.8
9.7
10.2
11.1
11.5
12.5
12.0
12.9
13.3
14.5
16.4
14.3
15.2
15.6
16.8
18.5
23.0
17.1
18.0
18.5
19.6
21.4
23.8
29.5
25.1
26.0
26.5
27.0
29.1
31.6
34.9
44.6
38.9
39.3
43.6
43.4
49.5
60.2
69.2
56.3
56.7
57.4
58.1
71.2
75.4
89.0
97.2

8.8
9.3
10.2
10.7
11.7
12.5
12.0
12.5
NC
14.6
17.0
14.3
14.8
15.8
16.8
19.0
23.9
17.1
17.6
18.6
19.6
21.9
24.7
30.5
25.1
25.6
26.6
27.0
29.6
32.5
35.9
47.0
38.5
39.4
43.6
43.9
50.5
61.4
72.1
55.9
NC
57.4
58.6
72.2
77.1
91.9
100.8

8.8
9.3
10.2
10.7
NC
12.5
12.0
12.5
NC
14.6
17.0
14.3
14.8
15.8
16.8
19.0
23.9
17.1
17.6
18.6
19.6
21.9
24.7
30.5
25.1
25.6
26.6
27.0
29.6
32.5
35.9
48.8
38.5
39.4
43.6
43.9
50.5
62.1
NC
55.9
NC
57.4
58.6
72.2
77.5
108.7
NC

9.4
10.3
11.4
12.3
12.8
13.8
13.2
14.1
14.6
15.8
17.2
15.2
16.1
16.6
17.7
19.5
23.0
18.9
20.0
20.5
21.5
24.0
25.5
30.5
25.5
26.5
27.0
28.0
30.0
33.0
36.0
45.5
39.2
39.7
45.1
32.5
50.7
62.0
72.6
56.8
57.3
58.3
40.0
72.2
77.0
91.6
101.0

9.4
10.3
11.4
12.3
12.8
13.8
13.2
14.1
14.6
15.8
17.2
15.2
16.1
16.6
17.7
19.5
23.0
18.9
20.0
20.5
21.5
24.0
25.5
30.5
25.5
26.5
27.0
28.0
30.0
33.0
36.0
45.4
39.2
39.8
45.1
32.5
50.7
61.9
72.2
56.8
57.3
58.3
40.0
72.2
76.9
91.2
100.3

9.4
9.9
11.4
11.9
12.4
13.8
13.2
13.9
14.4
15.8
17.7
15.2
15.7
16.2
17.7
20.0
23.9
18.9
19.6
20.0
21.5
24.5
26.4
31.5
25.5
26.1
26.6
28.0
30.5
33.9
37.0
46.9
39.2
38.8
45.1
33.0
51.7
63.4
75.1
56.4
NC
58.3
40.5
73.2
78.4
94.5
103.9

9.4
9.9
11.4
11.9
12.4
13.8
13.2
13.9
14.4
15.8
17.7
15.2
15.7
16.2
17.7
20.0
23.9
18.9
19.6
20.0
21.5
24.5
26.4
31.5
25.5
26.1
26.6
28.0
30.5
33.9
37.0
46.9
NC
NC
NC
46.5
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC

80

100

125

150

200

250

300

*rotatable flanges

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

29

Non-anchored double socket tees with flanged branch


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
STANDARD

EXPRESS

Weight with flange

Weight with flange

DN
body

dn
branch

Lu
mm

Hu
mm

PN 10
kg

350

60*
65*
80*
100*
150*
200*
250*
300*
350*
80*
100*
150*
200*
250*
300*
400*
100*
150*
200*
250*
300*
400*
450*
100*
150*
200*
250*
300*
400*
500*
100*
200*
300*
400*
600*
150*
200*
250*
400*
600*
700
150*
200*
250*
400*
600*
800
200*
250*
400*
600*
900

148
NC
194

322
NC
310

63
NC
72

400

450

500

600

700

800

900

*rotatable flanges

314
314
369
485
485
195
315
315
429
429
545
315
315
600
600
600
600
325
325
443
443
555
675
452
570
800
365
365
585
915
915
355
355
575
1015
1015
375
595
1145
1145

PN 16
kg

PN 25
kg

PN 10
kg

63
63
62
NC
NC
NC
72
72
70
Washout Tee see page 31
340
87
87
88
86
350
91
91
92
90
360
104
103
106
102
370
120
119
123
109
380
131
132
138
129
340
80
80
80
83
Washout Tee see page 31
370
100
100
101
100
380
105
105
106
8
390
125
125
127
117
400
133
134
137
121
420
162
166
175
164
Washout Tee see page 31
400
122
122
103
108
410
115
115
116
138
420
129,7
129
132
144
430
156,3
156
159
150
450
175
188
188
192
460
172
178
186
201
Washout Tee see page 31
430
143
143
144
150
440
147
147
148
154
450
173
173
175
179
460
181
180
184
192
480
215
219
228
221
500
258
271
277
264
185,5
Washout Tee see page 31
Washout Tee see page 31
520
228
228
231
236
540
271
275
284
278
580
373
398
401
381
520
262
262
263
262
525
265
265
266
266
Washout Tee see page 31
555
347
351
360
347
585
474
499
502
474
600
491
499
527
491
580
332
332
333
330
585
335
335
336
321
Washout Tee see page 31
615
430
435
444
429
645
617
642
645
614
675
663
674
715
661
645
420
419
422
419
Washout Tee see page 31
675
532
536
545
530
705
798
823
826
797
750
867
878
926
865
N C: Consult us

PN 16
kg

PN 25
kg

62
NC
70

62
NC
70

86
90
101
110
130
83

86
99
104
136
83

100
98
116
121
169

101
99
119
124
178

108
138
143
150
196
207

109
140
146
153
205
214

150
154
178
192
226
277
185

151
155
181
195
235
283
186

235
283
406
262
266

239
292
409
263
267

351
499
499
330
321

360
502
527
331
323

433
639
672
419

442
642
713
420

535
822
876

544
825
924

STD/EXP - DN 60 to 1200

STD - DN 1400 to 2000

Particular feature of washout tee:


connection geometry between
branch and body of flared shape.

30

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Non-anchored double socket tees with flanged branch


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
STANDARD
STD/EXP - DN 60 to 1200

DN
body

dn
branch

Lu
mm

Hu
mm

1000

150*
200*
250*
300*
400*
600*
1000
200*
250*
300*
400*
600*
700
800
900
1000
1100
200*
250*
300*
400*
600*
700
800
900
1000
1100
1200
400*
600*
800
900
1000
1200
1400
400*
600*
1500
300*
400*
500*
600*
1000
1600
200*
300*
400*
600*
800
900
1800
300*
400*
500*
600*
1000
1400

379
379

705
705

598
598
1258
1258
822

720
735
765
825
883

822
822
822
1245
1245
1245
1245
1245
855

840
835
865
900
915
930
920
907
883

855
855
855
1245
1245
1245
1480
1480
1480
1010
1010
1950
1950
1950
1950
1950
1110
1110
2050
1050
1050
1050
1050
1505
2170
1140
1155
1300
1300
1360
1360
2485
1265
1280
1295
1110
1580
2045

840
835
865
900
915
930
920
907
950
960
980
1040
1040
1040
1040
1040
960
980
1100
1050
1100
1075
1090
1150
1240
258
258
1300
1200
1230
1245
1380
290
290
290
1315
1370
1430

1100

STD - DN 1400 to 2000

1200

Particular feature of washout tee:


connection geometry between
branch and body of flared shape.

1400

1500

1600

1800

2000

*rotatable flanges

EXPRESS

Weight with flange


Weight with flange
PN 10
PN 16
PN 25
PN 10
PN 16
PN 25
kg
kg
kg
kg
kg
kg
447
447
447
451
451
452
510
510
512
453
453
454
Washout Tee see page 31
570
569
574
574
579
639
644
653
582
586
595
1007
1032
1035
950
975
978
1115
1137
1058
1080
1143
911
910
873
873
Washout Tee see page 31
910
909
886
999
894
899
907
915
940
NC
NC
NC
1341
NC
NC
NC
1351
1373
NC
1621
1651
949
949
950
949
Washout Tee see page 31
927
927
931
952
948
938
943
942
947
952
977
980
971
996
NC
NC
1336
1353
NC
1378
1397
NC
1532
1357
1380
2047
NC
1587
1732
1703
1760
Washout Tee see page 31
1542
1567
NC
NC
NC
2346
NC
Washout Tee see page 31
1790
1815
NC
1977
1967
Washout Tee see page 31
1989
1997
2022
2458
NC
NC
2320
Washout Tee see page 31
NC
2704
NC
NC
3201
3201
NC
3221
3235
Washout Tee see page 31
4564
NC
-

N C: Consult us

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Non-anchored double socket washout tees with flanged branch


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
STANDARD

EXPRESS
Weight with flange
PN 10
PN 16
PN 25
PN 40
kg
kg
kg
kg

DN
body

dn
branch

Lu
mm

Hu
mm

Weight with flange


PN 10
PN 16
PN 25
PN 40
kg
kg
kg
kg

250

100*
100*
100*
100*
100*
100*
200*
250*
250*
250*
250*
250*
250*
400*
400*
400*
400*
600*
600*

234
237
194
195
315
210
335
365
355
375
379
822
855
1010
1110
1050
1300
1300
1115

270
300
330
360
395
420
500
535
585
640
705
873
873
960
960
1100
1300
1200
1310

43
58
73
84
89
119
192
272
350
474
520
950
951
1520
1766
1977
2340
2360
3236

300

350
400
450
500

600
700
800
900
1000

1100
1200
1400
1500
1600
1800

1800
2000

43
58
73
84
89
119
192
271
349
474
519
950
950
1524
1771
1980
2345
2385
3261

44
59
73
84
89
119
193
274
352
477
522
950
953
1533
NC
NC
NC
NC
NC

44
59
119
195
-

32
40
71
84
119
126
199
272
343
464
545
NC
937
-

32
40
71
84
119
126
199
271
343
464
453
NC
937
-

33
40
71
84
119
126
200
274
346
467
456
NC
NC
-

*rotatable flanges

STD/EXP - DN 60 to 1200

STD - DN 250 to 2000

Fitting Pressure Classes


according to EN 545: 2010

DN

Pressure Class

40 to 100

100

125 to 200

64

250 to 350

50

400 to 600

40

700 to1400

30

1500 to 2000

25

See page 16 for the pressure rating of fittings


with STANDARD and EXPRESS joints

Particular feature of washout tee:


connection geometry between
branch and body of flared shape.

46
60
-

31

32

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Non-anchored double socket tapers


STANDARD DN 80 to 2000
EXPRESS DN 80 to 1200

STD/EXP - DN 80 to 1200

DN

dn

Lu
mm

80

60
60
80
60
80
100
60
80
100
125
100
125
150
125
150
200
150
200
250
200
250
300
250
300
350
300
350
400
350
400
450
400
450
500
500
600
600
700
700
800
800
900
1000
1000
1200
1200
1400
1200
1400
1500
1600
1800

103
100
104
150
120
105
200
170
130
107
230
180
125
275
225
125
321
222
123
335
260
187
335
260
176
335
234
166
378
290
160
460
360
258
480
267
467
280
480
280
480
280
305
480
360
410
100
645
350
400
427
472

100
125

150

200
STD - DN 80 to 2000

250

300

350

400

450

500

600

700
800
900
1000
1100
1200
1400
1500
1600

1800
2000

STANDARD

Non-anchored
EXPRESS collars
DN 60 to 2000

EXPRESS

Lu
mm

Lt
mm

EXPRESS

Weight
kg

Weight
kg

DN

6.1
6.8
7.5
8.9
8.9
9.4
11.2
10.3
11.1
11.7
17.3
16.8
16.7
26.2
26.0
25.3
36.5
35.9
36.0
54.5
52.0
55.0
65.0
60.0
62.0
77.8
71.3
69.2
88.6
86.5
80.0
156.0
125.0
120.0
198.0
176.0
255
243
338
307
417
378
NC
543
714
824
795
1065
1009
1187
1267
1776

7
7.7
8.7
9.5
9.9
10.4
12.2
12.6
12.6
13.0
18.3
18.0
18.0
30.0
30.0
30.5
40.0
40.5
35.0
54
52
53
65
60
62
82
76
74
97
91
78
137
123
125
189
166
237
220
304
265
363
313
419
517
-

60

156

320

6.9

80

158

328

8.8

100

160

334

10.8

125

163

343

13.5

150

165

351

16.7

200

170

368

23.5

250

170

385

37

300

180

400

49

350

185

405

55

400

190

410

67

450

195

391

76

500

200

440

100

600

210

450

131

700

220

500

183

800

230

510

226

900

240

520

274

1000

250

530

325

1100

260

660

500

1200

270

570

470

1400

340

560

1598

1500

Weight
kg

available in 2012

1600

360

600

2126

1800

368

640

2755

2000

available in 2012

New
EXPRESS collar DN 1400-2000

EXP - DN 60 to 2000

Drinking water supply, raw water and irrigation

Non-anchored flange-socket

DN

Lu / mm

60*
80*
100*
125*
150*
200*
250*
300*
350*
400*
450*
500*
600*
700*
800*
900*
1000*
1100*
1200*
1400*
1500*
1600*
1800*
2000*

142
110
110
110
115
120
135
130
135
140
145
170
170
190
200
210
220
220
240
310
360
330
387
395

PN 10
5.9
7.2
8.7
11.0
13.8
20.4
31.3
42.0
59
65
82
85
124
158
211
258
342
350
440
716
898
963
1212
1659

DN 60 - 2000

2012

PRODUCTS CATALOGUE

STANDARD DN 60 to 2000

Weight with flange / kg


PN 16
PN 25
5.9
7.2
8.7
11.0
13.8
20.3
30.9
41.3
59
69
88
98
149
166
220
268
359
386
484
768
986
1046
1305
1789

5.5
7.2
9.2
11.9
14.8
23.5
33.9
44.9
66
78
96
104
152
196
262
319
425
576
565
897
NC
NC
NC
NC

PN 40

STD - DN 60 to 2000

5.5
7.2
9.2
11.9
14.8
24.1
40.9
56.7
-

*rotatable flanges

Non-anchored flange-socket
DN

Lu / mm

60*
80*
100*
125*
150*
200*
250*
300*
350*
400*
450*
500*
600*
700*
800*
900*
1000*
1100*
1200*

126
128
105
110
110
115
125
130
145
150
155
180
190
190
200
210
220
220
240

*rotatable flanges

PN 10
6.0
8.2
7.2
9.2
11.3
16.3
25.4
32.5
57.6
66.5
82
93
124
159
205
248
310
363
451

EXPRESS DN 60 to 1200
Weight with flange / kg
PN 16
PN 25
6.0
8.2
7.2
9.2
11.3
16.2
25.0
31.8
58.4
70.0
88
106
149
167
213
258
327
399
496

6.2
8.2
5.2
10.2
12.3
17.7
28.0
35.4
64.5
79.0
96
112
152
197
256
309
393
585
576

PN 40
6.2
8.2
5.2
10.2
12.3
18.0
46.0
66.0
-

EXP - DN 60 to 1200

33

34

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Non-anchored flange-spigot
DN 60 to 2000

DN

Weight with flange / kg

Lu / mm
PN 10

PN 16

PN 25

PN 40

60*

350

5.6

5.6

80*

350

100*

350

8.6

8.6

6.5

6.5

125*

350

10.9

10.9

8.6

8.6

150*

400

14.0

14.0

15.0

15.0

200*

400

20.6

20.5

22.0

22.4

250*

400

34

33.5

32

300*

450

46.8

46.1

41.6

69

350*

450

58.6

59.4

55.5

400*

480

70

74

83

450*

500

86

92

100

500*

520

104

117

123

600*

560

144

169.5

172

700

600

189

187

225

800

600

239

250

291

900

600

287

298

346

1000

600

354

376

439

1100

600

400

438

513

1200

600

469

526

603

1400

710

674

726

855

1500

750

802

890

NC

1600

780

935

1019

NC

1800

845

1256

1359

NC

2000

885

1643

1749

NC

*rotatable flanges
NC: Consult us
Suitable for insert, anchored systems (Std Vi, Exp Vi, Std V+i, Uni Vi)

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

35

Anchored STANDARD socket pipes

77

144

80

6.00

6.00

98

167

100

6.00

5.95

118

188

125

6.00

5.95

144

215

150

6.00

6.00

170

242

200

6.00

5.96

222

295

250

6.00

5.95

274

352

300

6.00

5.95

326

409

350

6.00

5.97

378

464

400

6.00

5.97

429

516

450

6.00

5.97

480

574

500

6.00

5.97

532

629

600

6.00

5.97

635

738

700

6.00

5.97

738

863

800

6.95

6.89

842

974

900

6.95

6.87

945

1082

1000

6.95

6.88

1048

1191

1100

8.19

1151

1300

1200

8.18

8.15

1255

1412

1400

8.17

8.12

1462

1592

1500

8.16

8.11

1565

1710

1600

8.16

8.11

1668

1816

1800

8.15

8.08

1875

2032

2000

8.13

2082

2259

--(1) 5,97m pour UNI STD Ve and UNI STD Vi


*Consult us for UNIVERSAL / PAMLOCK weights

C40

UNI Ve

STD Ve

PAMLOCK

9.4

C40
12.2
C40
14.9
C40
18.3
C40
22.2
C40
30.2
C40
42.2
C40
55.5
C30
68.8
C30
79.4
C30
93.8
C30
111.1
C30
150.6
C25
186.2
C25
229.0
C25
276.2
C25
330.6
C25
395.4
C25
461.3
C25
634.3
C25
720.3
C25
807.5
C25
995.1
C25
1210.0

C100
15.2
C100
18.6
C64
22.9
C64
27.4
C64
38.5
C50
47.4
C40
55.5
C30
68.8
C30
79.4
C30
93.8
C30
111.1
C30
150.6
C25
186.2
C25
229.0
C25
276.2
C25
330.6
C25
395.4
C25
461.3
-

C100
15.8
C100
19.6
C64
24.3
C64
29.0
C64
40.1
C50
52.3
C50
67.4
C40
83.5
C40
98.2
C40
117.3
C40
139.2
C40
187.8
C30
229.1
C30
278.2
C30
339.5
C30
391.9
C30
554.1
C25
689.9
C25
780.6
C25
872.8
C25
1064.7
Consult us

UNI Vi*

6.00

STANDARD Ve UNI/PAMLOCK

STD Ve
STD V+i

60

STANDARD

UNI Vi

Anchored
Joint

PAMLOCK

UNI/PAMLOCK

Socket
B
mm

STD Vi

STANDARD

Pipe
DE
mm

Lu / m
DN

Average metric
Class & weight kg/m

UNI Ve*

36

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Vi`-/ , 6>iL
Pipes DN 60 to 600
STD Vi

DN
60
80
100
125
150
200
250
300

STANDARD Vi
Anchoring gasket
Weight kg
0.16
0.21
0.28
0.33
0.41
0.61
0.86
1.31

STANDARD Vi
Anchoring gasket
Weight kg
1.57
1.84
2.35
2.71
3.78
-

DN
350
400
450
500
600
-

Vi`1 6 ,-6>iL
Pipes DN 80 to 600
UNI Vi (inserts)

DN
80
100
125
150
200
250
300
350
400
450
500
600

UNI Vi
Anchoring gasket
Weight kg
0.15
0.20
0.26
0.31
0.49
0.61
0.78
1.47
1.70
1.87
2.54
3.00

STANDARD
Sealing gasket
Weight kg
0.14
0.19
0.24
0.28
0.38
0.49
0.71
0.89
1.07
1.32
1.54
2.16

Total accessories
Weight kg
0.29
0.39
0.50
0.59
0.87
1.10
1.49
2.36
2.77
2.19
4.08
5.16

Vi`1 6 ,-6i>iL
Pipes DN 100 to 1200
UNI Ve (weld bead)

DN
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1200

UNI Ve
Anchoring ring
Weight kg
0.54
0.70
0.90
1.30
1.30
1.80
2.30
3.60
4.05
4.60
8.60
9.70
17.3
22.6
24.8
26.9

Number of segments
3
3
4
4
1
1
1
1
1
1
1
1
7
8
9
10

STANDARD
Sealing gasket
Weight kg
0.19
0.24
0.28
0.38
0.49
0.71
0.89
1.07
1.32
1.54
2.16
2.87
3.67
4.61
5.58
9.33

Vi`-/ , 6>iL
Fittings DN 350 to 600
STD V+i (inserts + gland)

DN

350
400
450
500
600

Gland
ext
mm
570
618
671
734
840

Weight
kg
30.5
37.7
43.0
61.7
63.5

Anchoring
gasket

Ductile
iron bolts

Weight
kg
1.40
1.70
1.80
2.54
3.00

Nbr
8
10
14
16
20

STANDARD
sealing
gasket
Weight
kg
0.90
1.10
1.32
1.54
2.16

Total
accessories
Weight
kg
39.02
46.60
57.10
74.68
84.46

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

37

Vi`-/ , 6i>iL
*i nU} n
STD Ve (weld bead + gland)

ext
mm

Weight
kg

Weight
kg

Nbr

STANDARD
sealing
gasket
Weight
kg

80

233

3.5

0.56

0.15

5.76

100

254

4.8

0.49

0.20

7.04

125

285

5.9

0.69

0.24

11.16

150

310

7.5

0.95

0.29

11.06

200

363

9.5

1.5

0.38

14.50

250

456

21.0

2.8

0.50

29.04

300

516

28.0

3.7

0.71

38.73

350

570

30.5

4.5

0.90

42.22

400

618

37.7

4.5

10

1.10

51.20

450

671

43

6.0

14

1.32

60.90

500

734

61.7

6.7

16

1.54

82.58

600

840

63.5

9.6

20

2.16

91

700

958

109

14.6

24

2.87

148

800

1100

140

15.7

30

3.67

181

900

1218

184

17.2

30

4.61

228

1000

1306

211

19.3

30

5.59

258

1100

1417

232

17.5

40

7.68

291

1200

1547

222

21.5

40

9.34

287

DN

Gland

Locking
ring

Ductile
iron bolts

Total
accessories
Weight
kg

Anchored PAMLOCK>iL
Pipes and fittings DN 1400 to 2000
PAMLOCK

Conformator
DN

Steel
shot

Locking
ring

STANDARD
Sealing gasket

Total
accessories

Weight
kg

Weight
kg

Weight
kg

Weight
kg

Weight
kg

1400

71

15

46

15.5

148

1500

76

15

41

19.8

152

1600

81

15

45

21.0

162

1800

92

15

54

27.7

189

2000

Consult us

Consult us

Consult us

Consult us

Consult us

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

STD - DN 60 to 1200
EXP - DN 60 to 300
STD Pk - DN 1400 to 2000

Anchored double socket bends


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200
1/4
Lu
mm

DN

1/8

Weight
kg

Lu
mm

1/16

Weight
kg

Lu
mm

Anchored
Joint

1/32

Weight
kg

Lu
mm

Weight
kg

STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP STD EXP
6.4

76

76

6.5

6.7

30

30

4.9

5.6

35

35

5.1

5.7

80

91

91

7.6

8.7

56

56

8.1

32

32

6.2

7.4

40

40

6.5

7.6

100

105 102 10.0 6.8

65

60

8.9

6.0

35

35

7.8

5.4

40

30

7.9

5.3

125

133 130 13.9 9.0

83

65 12.3 7.6

38

40

9.9

6.8

45

35 10.3 6.6

150

152 150 18.1 11.5 92

75 15.6 9.5

42

45 12.2 8.4

46

35 12.6

200

200 200 29.2 18.8 100 95 23.7 14.6 51

55 18.9 12.5 52

40 19.2 11.6

250

252 250 49.6 33.5 139 115 40.5 25.9 70

65 32.2 22

55

50 30.5 20.8

300

304 280 72.7 43.1 167 150

59 35.6 90

75 42.2 26.8 50

55 39.7 26.6

350

390 390 115

168 168

69

72

78

78

53

57

53

53

49 48.5

400

436 436 141 140 189 189

89

91

92

92

69

71

58

58

62 64.5

450

482 482 150 170 216 216 118 120 100 100

88

92

67

67

80

84

500

525 525 216 215 220 220 146 155 110 110 108 118

71

71

96

106

600

624 624 311 312 283 283 208 234 140 140 144 166

94

94

128 148

700

670

584

335 335 311 312 157 157 231 232

87

87

196 197

800

735

696

364 364 414 417 170 170 303 305

90

90

253 255

900

880

800

403 403 545 551 197 197 406 406 102 102 326 332

1000 1000 -

1461

440 439 703 649 217 217 507 459 117 117 414 360

95

1100

540 540 993 993 275 275 650 663 140 140 490 589

1200

537 537 1015 1033 258 258 644 675 138 138 478 509

1400

522

1555

264

1107

143

884

1500

572

1815

314

1367

193

1143

1600

563

2089

284

1479

153

1173

1800

642

3126

337

2070

200

1542

2000

NC

NC

355

2668

200

2151

N C : Consult us

+ : Pamlock socket

*for UNIVERSAL / PAMLOCK fittings, please consult us for the weight

UNI Vi*

6.2

STD Ve
STD V+i

75

UNI Ve

75

PAMLOCK

60

EXP Vi

STD Vi

38

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

39

Anchored double socket tapers


STANDARD DN 80 to 2000 / EXPRESS DN 80 to 300

103
100
104
150
120
105
200
170
130
107
230
180
125
275
225
125
325
225
125
335
260
190
340
265
175
335
240
170
360
260
160
460
360
260
480
280
480
280
480
280
480
280
NC
480
345
478
183
645
350
483
428
NC

7
7.7
8.7
9.5
9.9
10.4
12.2
12.6
12.6
13
18.3
18
18
30
30
30.5
40
40.5
39
54
52
53
65
60
62
82
75
74
89
86
80
131
125
120
210
176
255
243
338
307
417
378
NC
543
725
888
883
1178
1146
1132
1640
NC

125
150

200
250
300
350
400
450

500

600

700
800
900
1000
1100
1200
1400
1500
1600

1800
2000
N C : Consult us

*for UNIVERSAL/PAMLOCK fittings, please consult us for the weight

PAMLOCK - DN 1400 to 2000

STD V+i

60
60
80
60
80
100
60
80
100
125
100
125
150
125
150
200
150
200
250
200
250
300
250
300
350
300
350
400
350
400
450
400
450
500
500
600
600
700
700
800
800
900
1000
1000
1200
1200
1400
1200
1400
1500
1600
NC

EXP - DN 80 to 300

UNI Vi*

80
100

STD - DN 80 to 1200

Anchored
Joint

STD Ve

Weight
kg

UNI Ve*

L
mm

PAMLOCK

dn

EXP Vi

DN

STD Vi

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Anchored double socket tees with flanged branch


STANDARD DN 60 to 2000 / EXPRESS DN 60 to 1200

80

100

125

150

200

250

300

Lu
mm

Hu
mm

40*
60*
40*
60*
65*
80*
40*
60*
65*
80*
100*
40*
60*
65*
80*
100*
125*
40*
60*
65*
80*
100*
125*
150*
40*
60*
65*
80*
100*
125*
150*
200*
60*
65*
80*
100*
150*
200*
250*
60*
65*
80*
100*
150*
200*
250*
300*

154
154
145
145
145
183
150
150
150
185
210
150
150
150
165
190
267
154
154
154
165
190
220
305
159
159
159
170
195
220
250
360
164
164
234
234
251
344
404
237
237
237
237
347
347
467
467

141
161
149
169
174
165
161
181
186
177
180
164
184
189
195
200
200
176
196
201
210
215
210
220
209
229
234
240
245
240
245
260
272
272
250
270
280
290
300
297
297
298
300
310
320
305
340

8.8
9.7
10.2
11.1
11.5
12.5
12.0
12.9
13.3
14.5
16.4
14.3
15.2
15.6
16.8
18.5
23.0
17.1
18.0
18.5
19.6
21.4
23.8
29.5
25.1
26.0
26.5
27.0
29.1
31.6
34.9
44.7
38.9
39.3
43.6
43.4
49.5
60.3
69.6
56.3
56.7
57.4
58.1
71.2
75.7
89.4
97.9

*rotatable flanges

N C : Consult us

8.8
9.7
10.2
11.1
11.5
12.5
12.0
12.9
13.3
14.5
16.4
14.3
15.2
15.6
16.8
18.5
23.0
17.1
18.0
18.5
19.6
21.4
23.8
29.5
25.1
26.0
26.5
27.0
29.1
31.6
34.9
44.6
38.9
39.3
43.6
43.4
49.5
60.2
69.2
56.3
56.7
57.4
58.1
71.2
75.4
89.0
97.2

8.8
8.8
9.4
9.4
9.4
9.3
9.3
10.3 10.3
9.9
10.2 10.2 11.4 11.4 11.4
10.7 10.7 12.3 12.3 11.9
11.7
NC
12.8 12.8 12.4
12.5 12.5 13.8 13.8 13.8
12.0 12.0 13.2 13.2 13.2
12.5 12.5 14.1 14.1 13.9
NC
NC
14.6 14.6 14.4
14.6 14.6 15.8 15.8 15.8
17.0 17.0 17.2 17.2 17.7
14.3 14.3 15.2 15.2 15.2
14.8 14.8 16.1 16.1 15.7
15.8 15.8 16.6 16.6 16.2
16.8 16.8 17.7 17.7 17.7
19.0 19.0 19.5 19.5 20.0
23.9 23.9 23.0 23.0 23.9
17.1 17.1 18.9 18.9 18.9
17.6 17.6 20.0 20.0 19.6
18.6 18.6 20.5 20.5 20.0
19.6 19.6 21.5 21.5 21.5
21.9 21.9 24.0 24.0 24.5
24.7 24.7 25.5 25.5 26.4
30.5 30.5 30.5 30.5 31.5
25.1 25.1 25.5 25.5 25.5
25.6 25.6 26.5 26.5 26.1
26.6 26.6 27.0 27.0 26.6
27.0 27.0 28.0 28.0 28.0
29.6 29.6 30.0 30.0 30.5
32.5 32.5 33.0 33.0 33.9
35.9 35.9 36.0 36.0 37.0
47.0 48.8 45.5 45.4 46.9
38.5 38.5 39.2 39.2 39.2
39.4 39.4 39.7 39.8 38.8
43.6 43.6 45.1 45.1 45.1
43.9 43.9 32.5 32.5 33.0
50.5 50.5 50.7 50.7 51.7
61.4 62.1 62.0 61.9 63.4
72.1
NC
72.6 72.2 75.1
55.9 55.9 56.8 56.8 56.4
NC
NC
57.3 57.3
NC
57.4 57.4 58.3 58.3 58.3
58.6 58.6 40.0 40.0 40.5
72.2 72.2 72.2 72.2 73.2
77.1 77.5 77.0 76.9 78.4
91.9 108.7 91.6 91.2 94.5
100.8 NC 101.0 100.3 103.9

9.4
9.9
11.4
11.9
12.4
13.8
13.2
13.9
14.4
15.8
17.7
15.2
15.7
16.2
17.7
20.0
23.9
18.9
19.6
20.0
21.5
24.5
26.4
31.5
25.5
26.1
26.6
28.0
30.5
33.9
37.0
46.9
NC
NC
NC
46.5
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC

Anchored
Joint

for UNIVERSAL /PAMLOCK fittings, please consult us for the weight

UNI Vi

60

dn
branch

STD Ve (weld bead and gland)

DN
body

EXPRESS

UNI Ve

STANDARD

Weight with flange


Weight with flange
PN 10 PN 16 PN 25 PN 40 PN 10 PN 16 PN 25 PN 40
kg
kg
kg
kg
kg
kg
kg
kg

EXP Vi

STD Vi

40

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Anchored double socket tees with flanged branch


STANDARD DN 350 to 2000

600

700

800

900

STD
DN 350
to 1200

STD V+i

1200

1400

1500

1600

1800

2000

STD Pk
DN 1400
to 2000

379 705 447 447 447


379 705 510 510 512
Washout Tee see page 42
598 720 570 569 574
598 735 639 644 653
1258 765 1007 1032 1035
1258 825 1115 1137 822 883 911 910
Washout Tee see page 42
822 840 910 909
822 835 999
822 865 907
1245 900 NC
1245 915 NC
1245 930 NC
1245 920 NC
1245 907 NC
855 883 949 949 950
Washout Tee see page 42
855 840 927 927 931
855 835 938 943
855 865 952 977 980
1245 900 NC
1245 915 1336 1353 1245 930 1378 1397 1480 920
- 1532
1480 907
- 2047 1480 950 1587 1732 Washout Tee see page 42
1010 980 1542 1567 1950 1040 NC
1950 1040 NC
1950 1040 NC
1950 1040
- 2346
1950 1040 NC
Washout Tee see page 42
1110 980 1790 1815 2050 1100 NC
1050 1050 1977 1967 Washout Tee see page 42
1050 1075 1989 1050 1090 1997 2022 1505 1150
- 2458 2170 1240 NC
1140 258 NC
1155 258 2320 Washout Tee see page 42
1300 1200 NC
1360 1230 2704 1360 1245 NC
2485 1380 NC
1265 290 3201 3201 1280 290 NC
1295 290 3221 3235 Washout Tee see page 42
1580 1370 4564 2045 1430 NC
-

*rotatable flanges

Anchored
Joint

UNI Ve

PN10 PN16 PN40


kg
kg
kg

STD Ve

UNI Vi

1100

150*
200*
250*
300*
400*
600*
1000
200*
250*
300*
400*
600*
700
800
900
1000
1100
200*
250*
300*
400*
600*
700
800
900
1000
1100
1200
400*
600*
800
900
1000
1200
1400
400*
600*
1500
300*
400*
500*
600*
1000
1600
200*
300*
400*
600*
800
900
1800
300*
400*
500*
600*
1000
1400

H
mm

UNI Ve

500

DN
dn
L
body branch mm
1000

UNI Vi
STD Ve (weld bead and gland)

450

148 322
63
63
63
NC
194 310
72
72
72
Washout Tee see page 42
314 340
87
87
88
314 350
91
91
92
369 360 104 103 106
485 370 120 119 123
485 380 131 132 138
195 340
80
80
80
Washout Tee see page 42
315 370 100 100 101
315 380 105 105 106
429 390 125 125 127
429 400 133 134 137
545 420 162 166 175
Washout Tee see page 42
315 400 122 122 103
315 410 115 115 116
600 420 129,7 129 132
600 430 156,3 156 159
600 450 175 188 188
600 460 172 178 186
Washout Tee see page 42
325 430 143 143 144
325 440 147 147 148
443 450 173 173 175
443 460 181 180 184
555 480 215 219 228
675 500 258 271 277
Washout Tee see page 42
Washout Tee see page 42
452 520 228 228 231
570 540 271 275 284
800 580 373 398 401
365 520 262 262 263
365 525 265 265 266
Washout Tee see page 42
585 555 347 351 360
915 585 474 499 502
915 600 491 499 527
355 580 332 332 333
355 585 335 335 336
Washout Tee see page 42
575 615 430 435 444
1015 645 617 642 645
1015 675 663 674 715
375 645 420 419 422
Washout Tee see page 42
595 675 532 536 545
1145 705 798 823 826
1145 750 867 878 926

Anchored
Joint

UNI Ve

400

60*
65*
80*
100*
150*
200*
250*
300*
350*
80*
100*
150*
200*
250*
300*
400*
100*
150*
200*
250*
300*
400*
450*
100*
150*
200*
250*
300*
400*
500*
100*
200*
300*
400*
600*
150*
200*
250*
400*
600*
700
150*
200*
250*
400*
600*
800
200*
250*
400*
600*
900

PN10 PN16 PN40


kg
kg
kg

STD Vi

350

H
mm

UNI Ve

dn
L
DN
body branch mm

Weight with flange

PAMLOCK (weld bead and double chamber)

Weight with flange

for UNIVERSAL /PAMLOCK fittings,


please consult us for the weight

41

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

STD Pk - DN 1400 to 2000

DN 250 to 1200

Particular feature of washout tee:


connection geometry between
branch and body of flared
shape.

Anchored double socket washout tees with flanged branch


STANDARD DN 250 to 2000

L
mm

H
mm

250

100*

234

270

43

43

44

44

300

100*

237

300

58

58

59

59

350

100*

194

330

73

73

73

400

100*

195

360

84

84

84

450

100*

315

395

89

89

89

500

100*

210

420

119

119

119

119

600

200*

335

500

192

192

193

195

700

250*

365

535

272

271

274

800

250*

355

585

350

349

352

900

250*

375

640

474

474

477

1000

250*

379

705

520

519

522

1100

250*

822

873

950

950

950

1200

250*

855

873

951

950

953

1400

400*

1010

960

1520

1524

1533

1500

400*

1110

960

1766

1771

NC

1600

400*

1050

1100

1977

1980

NC

1800

400*

1300

1300

2340

2345

NC

1800

600*

1300

1200

2360

2385

NC

2000

600*

1115

1310

3236

3261

NC

*rotatable flanges

+ : PAMLOCK socket

Anchored
Joint

STD V+i

dn
branch

UNI Vi
STD Ve

PN 40
kg

DN
body

PAMLOCK

Weight with flange


PN 10
PN 16
PN 25
kg
kg
kg

STD Vi

UNI Ve

42

for UNIVERSAL / PAMLOCK fittings, please consult us for the weight

Drinking water supply, raw water and irrigation

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Anchored flange-socket
EXPRESS DN 60 to 300

L
mm

60*
80*
100*
125*
150*
200*
250*
300*

126
128
130
120
125
130
155
165

6.1
7.9
9.5
11.5
15.1
21.0
26.5
35.5

6.1
7.9
9.5
11.5
15.1
21.0
26.5
35.0

5.7
7.9
10.0
12.4
16.1
22.5
29.0
38.5

Anchored
Joint

PN 40
kg
5.7
7.9
10.0
12.4
16.1
24.0
46.0
66.0

EXP - DN 60 to 300

EXP Vi

DN

Weight with flange


PN 10
PN 16
PN 25
kg
kg
kg

*rotatable flanges

Anchored flange-socket
STANDARD DN 60 to 2000

*rotatable flanges

5.9
7.1
8.7
11.0
13.8
20.4
31.3
42.0
59
65
82
85
124
158
211
258
342
350
440
716
898
963
1212
1659

5.9
7.1
8.7
11.0
13.8
20.3
30.9
41.3
59
69
88
98
149
166
220
268
359
386
484
768
986
1046
1305
1789

5.5
7.1
9.2
11.9
14.8
21.8
33.8
44.9
66
78
96
104
152
196
262
319
425
572
565
897
1122
1194
1502
2084

5.5
7.1
9.2
11.9
14.8
22.2
43.2
56.7
-

UNI Vi

142
110
110
110
115
120
125
130
135
140
145
170
180
190
200
210
220
230
225
310
360
330
387
395

Anchored
Joint

STD Ve (weld bead and gland)


STD V+i

60*
80*
100*
125*
150*
200*
250*
300*
350*
400*
450*
500*
600*
700*
800*
900*
1000*
1100*
1200*
1400
1500
1600
1800
2000

PN 40
kg

UNI Ve

L
mm

PAMLOCK

DN

Weight with flange


PN 10
PN 16
PN 25
kg
kg
kg

STD Vi

STD - DN 1400 to 2000

43

Drinking water supply, raw water and irrigation

Spigot without metallic


guide bead (for insert
restraint systems STD Vi,
STD V+i, EXP Vi, UNI Vi)

DN 60 - 2000

2012

PRODUCTS CATALOGUE

Anchored flange-spigot with metallic bead

DN 80 to 2000

See page 32 for flange

Weight with flange


PN 10
PN 16
PN 25
kg
kg
kg

PN 40
kg

DN

L
mm

80*

350

8.0

8.0

8.0

8.0

100*

350

9.6

9.6

10.1

10.1

125*

350

12.5

12.5

13.4

13.4

150*

400

17.1

17.1

18.1

18.1

200*

400

24.5

24.0

25.5

27.5

250*

400

33.0

33.0

35.5

46.0

300*

450

46

45

49

65

350*

450

58

58

64

400*

480

70

74

83

450*

500

86

92

100

500*

520

104

117

123

600*

560

144

169

172

700*

600

189

187

225

800*

600

239

250

291

900*

600

287

298

346

1000*

600

354

376

439

1100*

600

400

435

513

1200*

600

469

526

603

1400*

710

674

726

855

1500*

750

802

890

1026

1600*

780

935

1019

1167

1800*

845

1256

1359

1556

2000*

Consult us

*rotatable flanges

Suitable for inserts, not-anchored systems (Std Vi, Exp V+i, Std V+i, Uni Vi)

Anchored
Joint

STD Ve (weld bead and gland) or UNIVERSAL Ve

PAMLOCK

44

Drinking water supply, raw water and irrigation

DN 60 - 2000

| 2012 | 45

PAM commitments

Saint-Gobain PAM - Pont--Mousson Factory

SUSTAINABLE DEVELOPMENT COMMITMENT FROM SAINT-GOBAIN PAM


Saint-Gobain PAM is the world leader in water cycle
pipeline systems. Whilst this is a cause of great pride for
all those that work with and for the company, it is also an
immense responsibility.
Sustainable development lies at the heart of its
corporate culture. Saint-Gobain PAM rapidly embraced
the pioneering principles of sustainable development
formulated by the Brundtland Commission. Since 1987,
this international commission has encouraged todays
generations to meet the needs of the present without
compromising the ability of future generations to meet
their own needs.
Its state-of-the-art technologies and focus on research
and development have enabled it to consistently provide
its customers with quality, sustainable, reliable and

ergonomic solutions.
Like communication channels, water and sewerage
pipelines are infrastructures created to last for several
generations. Sustainable development depends on long
lasting rather than disposable installations.
Saint-Gobain PAM has taken on board these principles and
works to provide effective solutions for the environment.
More than 100 capitals and over 1000 large cities
worldwide have been equipped with Saint-Gobain PAM
products.
Numerous hydraulic, water and sewerage projects are
currently run with the support of Saint-Gobain PAM
in order to boost the development of countries mainly
in Latin America and Africa, but also in China and the
Middle East.

| Drinking water supply, raw water and irrigation

46

PAM commitments

| DN 60 - 2000

| 2012

PRESSURE CLASSES RANGES


h PAM played a leading role
in the development
of new pressure classes
h HYDROCLASS, CLASSIC
and NATURAL are available
in pressure classes
h The whole range of PAM
products is available
in pressure classes
h HYDROPAM and ALPINAL
for higher pressure ranges
h IRRIGAL for irrigation and
URBITAL for recycled water

MATERIAL IN CONTACT WITH DRINKING WATER


h EN 545 includes reference
to the need for compliance
with national water quality
regulations where they exist:
- France NF EN 545: ACS
- United Kingdom BS
EN 545: DWI, WRAS
- Germany DIN EN 545:
DVGW GW337 + W270,
KTW
h PAM solutions comply with
Standards
and legislation, among
which:
France (ACS), United
Kingdom
(Regulation 31.4 and WRAS),
Germany (DVGW) and the
Netherlands (KIWA)

Drinking water supply, raw water and irrigation

SUSTAINABLE DEVELOPMENT
h PAM is certied to ISO
14001:2004 by a third party
organization
h ZINALIUM external coating
triples the lifetime of
pipelines in most situations
h In 15 years, PAM has reduced
energy requirements by an
average of 30% to produce
a pipe of the same DN

QUALITY MANAGEMENT
h PAM is certied to ISO
9001:2008 by accredited
third party organization for
design, manufacture
and marketing of its products
h PAM has its own additional
technical specications,
which are even more
demanding than those of the
EN 545 Standard
h PAM provides a complete,
consistent and homogeneous
range of pipes, ttings and
joints, designed and tested
for the highest performances

PERFORMANCES
h PAM has the performance of its joints certied
by a third party organization
h The angular deflection provided by the flexible joints of PAM
products are greater than those specified in the Standard
h PAM joints are certied by tests in COFRAC (ISO/CEI 17 001)
accredited laboratories

DN 60 - 2000

| 2012 | 47

PAM commitments

Service,

PAM's commitment
Guiding you
with your projects >
a team of specialists
at your side

PAM is present
at every step of your project:
U Design
U Implementation
U After-sales
PAM services offers you:
U Support with the preparation
of technical les
U Studies adapted to the type of
your work sites
U Technical diagnosis and soil surveys
U Technical support on work sites
(training when starting work sites,
support when carrying out the work)
U After-sales technical support
U Information, recommendations
and training for commissioning

PAM customer school >


our skills at your service

Pam provides your employees


with training on the
implementation of its products
for optimum efciency on site.
U PAM customer school:
Training of installers,
maintenance technicians,
support on site in the elds
of drinking water supply,
sewerage, valves and ttings
and municipal castings in our
internal training centre.

PAM service undertakes to provide you with long-term sustainable technical


solutions, permanent innovation and expertise from our specialists.
A sustainable partnership based on trust, PAM is present beside you.

Commitment
of the sales teams >
PAM innovation >
benet from the discoveries
made by PAM scientists

Every year, PAM engineer-scientists


le more than a hundred patents.
They collaborate with numerous
universities.
Their expertise in the elds of
metallurgy, strength of materials,
coatings and the manufacturing
processes is at your service to
propose all these innovations.
A few recent examples:

guarantee the success


of your projects

,iviiViiVV>
tools >
to help you
with decision-making

PAM offers you performant tools


to help you make the best possible
choices for your networks:

Every order is followed by a sales


assistant who works jointly with
the sector manager.

U PAMCAD: network design tools

This team is your key partner to


guarantee the success of your
projects!

U Web sites:
U www.pamline.com
U www.blutop.fr

They work in close collaboration


with:
U our marketing teams,
U our product development teams,
U our plants,

U Technical documentation :
U drinking water supply
and sewerage bibles
U laying recommendations
U catalogues
U ductile iron pipelines:
compendium
U multimedia animations

to offer you the best drinking water


and sewerage networks.

at your side

SAINT-GOBAIN PAM worldwide


ALGERIA

COLOMBIA

HONG KONG

PORTUGAL

SAINT-GOBAIN PAM ALGERIE


Z.I. Sidi Abdelkader-Ben Boulaid - BP 538
09000 - BLIDA - Algeria
Phone: + 213 (0) 25 36 00 60

SAINT-GOBAIN PAM COLOMBIA


Terminal terrestre de carga de Bogota
Etapa 1, Bodega 9, Modulo 3
Km 3,5 costado sur autopista - Medellin
COTA CUNDINAMARCA - Colombia
Phone: + 57 (1) 841 5832

SAINT-GOBAIN PIPELINES
H15/F Hermes Commercial Centre - 4-4A Hillwood Road
TSIM SHA TSUI - KOWLOON - Hong Kong
Phone: + 852 27 35 78 26

SAINT-GOBAIN PAM PORTUGAL


Est. Nac. 10 - Lugar de D. Pedro -Apartado 1708
P-2691-901 - SANTA IRIA DE AZOIA - Portugal
Phone: + 351 218 925 000

INDIA

ROMANIA

SAINT-GOBAIN PAM
Grindwell Norton Ltd
5th Level, Leela Business Park - Andheri-Kurla Road
MUMBAI - 400059 - India
Phone: + 91 22 402 12 121

SAINT-GOBAIN CONSTRUCTION PRODUCTS


ROMANIA S.R.L. - PAM Business Unit
Strada Tipogralor nr. 11-15, Corp 84,
Etaj 3, Birourile 323-338, Sector 1,
BUCHAREST - Romania
Phone: + 40 21 207 57 37

SAINT-GOBAIN PAM ARGENTINA


Bouchard y Enz
1836 - LLAVALLOL - BUENOS AIRES - Argentina
Phone: + 54 11 42 98 9600

AUSTRALIA
SAINT-GOBAIN PAM
15 Edgars Road
THOMASTOWN VIC 3074 - Australia
Phone: + 61 (0) 3 9358 6122

AUSTRIA
SAINT-GOBAIN GUSSROHRVERTRIEB
STERREICH GmbH
Archenweg, 52
A-6020 - INNSBRUCK - Austria
Phone: + 43 512 341 717-0

BELGIUM
SAINT-GOBAIN PIPE SYSTEMS
Raatshovenstraat, n2
B-3400 - LANDEN - Belgium
Phone: + 32 11 88 01 20

BRAZIL
SAINT-GOBAIN CANALIZACAO LTDA
Praia de Botafogo 440 7 andar
22250-040 - RIO DE JANEIRO - RJ - Brazil
Phone: + 55 21 2128 1677

CHILE
SAINT-GOBAIN PAM CHILE
Antillanca Norte 600
Parque Industrial Vespucio, Comuna de Pudahuel
SANTIAGO DE CHILE - Chile
Phone: + 562 444 13 00

CHINA
SAINT-GOBAIN PAM CHINA (SHANGAI)
1812 Ocean Tower
550 Yan'An East Road - SHANGAI 200001 - China
Phone: + 86 21 6361 2165
SAINT-GOBAIN PAM CHINA (XUZHOU)
Dong Jiao Yangzhuang
PC 221004 - XUZHOU - Jiangsu Province - China
Phone: + 86 516 8787 8107
SAINT-GOBAIN PAM CHINA (MAANSHAN)
Hua Gong Road Cihu
PC 243052 - MAANSHAN Anhui Province - China
Phone: + 86 555 350 8040

www.pamline.com
SAINT-GOBAIN PAM
Head ofce
91, avenue de la Libration
54076 NANCY CEDEX
FRANCE
Marketing Department
Water & Sewage
21, avenue Camille Cavallier
54705 PONT-A-MOUSSON CEDEX
FRANCE
Phone: +33 (0)3 83 80 73 50

CZECH REPUBLIC
SAINT-GOBAIN PAM CZ s.r.o.
Po ernick 272/96
108 03 Praha 10 - Czech Republic
Phone: + 296 411 746

ITALY
FINLAND
SAINT-GOBAIN PIPE SYSTEMS OY
Nuijamiestentie 3A
FIN-00400 - HELSINKI - Finland
Phone: + 358 207 424 600

SAINT-GOBAIN PAM ITALIA SPA


Via Romagnoli n6
I-20146 - MILAN - Italy
Phone: + 39 02 42 431

JORDAN
FRANCE & DOM-TOM
SAINT-GOBAIN PAM (HEAD OFFICE)
91 Avenue de la Libration
54076 NANCY CEDEX - France
Phone: +33 3 83 95 20 00

SAINT-GOBAIN PAM REGIONAL OFFICE


Abu Zaid Center - Ofce # 8
35 Saad Bin Abi Waqqas St, - PO BOX 831000
11183 AMMAN - Jordan
Phone: + 962 6 551 4438

SAINT-GOBAIN PAM
(France Commercial Department)
CRD Chemin de Blnod B.P. 109
54704 PONT A MOUSSON CEDEX - France
Phone: +33 3 83 80 73 00

MOROCCO

SAINT-GOBAIN PAM
(Europe and International Commercial Departments)
21 avenue Camille Cavallier
54705 - PONT A MOUSSON CEDEX - France
Phone: + 33 3 83 80 67 89

MEXICO

SAINT-GOBAIN PAM
(Local Agency of The Antilles)
Rue Alfred Lumire - ZI de Jarry - BP 2104
97122 - BAIE MAHAULT - Guadeloupe
Phone: + 33 590 26 71 46
SAINT-GOBAIN PAM
(Local Agency of Indian Ocean)
16, Rue Claude Chappe - ZAC 2000
97420 - LE PORT - Reunion Island
Phone: + 33 262 55 15 34

GERMANY
SAINT-GOBAIN PAM DEUTSCHLAND
Saarbrucker Strasse 51
66130 - SAARBRUCKEN - Germany
Phone: + 49 681 87 010

GREECE
SAINT-GOBAIN SOLINOURGEIA
5 Klissouras Str.
GR 14482 - METAMORFOSI - ATHENS - Greece
Phone: + 30 210 28 31 804

SAINT-GOBAIN PAM REGIONAL OFFICE


2 alle des Figuiers - An Seba
CASABLANCA - Morocco
Phone: + 212 522 66 57 31

SAINT-GOBAIN PAM MEXICO


HORACIO 1855-502 - Colonia Los Morales - Polanco
11510 - MEXICO D.F. - Mexico
Phone: + 52 55 5279 1657

NETHERLANDS
SAINT-GOBAIN PIPE SYSTEMS
Markerkant 10-17
1316 - AB ALMERE - Nederland
Phone: + 31 36 53 333 44

NORWAY
SAINT-GOBAIN BYGGEVARER AS
DIvision PAM Norge
Brobekkveien 84
0582 - OSLO - Norway
Phone: + 47 23 17 58 60

PERU
SAINT-GOBAIN PAM PERU
Avenida de los Faisanes N 157 - Chorillos
LIMA 09 - Peru
Phone: + 511 252 40 34/35

SLOVAKIA
SAINT-GOBAIN CONSTRUCTION PRODUCTS
PAM Business Unit
Stara Vajnorska 139
83104 - BRATISLAVA - Slovakia
Phone: + 421 265 45 69 61

SOUTH AFRICA
SAINT-GOBAIN CONSTRUCTION PRODUCTS
PAM Business Unit
N1 Business Park
Corner Olievenhoutbosch Road & Old Johannesburg Road
Samrand - PO BOX 700
GERMISTON - South Africa 1400
Phone: +27 12 657 2800

SPAIN
SAINT-GOBAIN PAM ESPANA SA
Paseo de la Castellana n77 - Edicio Ederra - Planta 10
E-28046 - MADRID - Spain
Phone: + 34 91 397 20 00

UNITED ARAB EMIRATES


SAINT-GOBAIN PAM
PO BOX 47102 - Building N 1092 - Villa N 7
Muroor Road - ABU DHABI - United Arab Emirates
Phone: + 971 2 448 20 10

UNITED KINGDOM
SAINT-GOBAIN PAM UK
Lows Lane - Stanton-by-Dale
ILLKESTON - DERBYSHIRE - DE7 4QU
United Kingdom
Phone: + 44 115 930 5000

VIETNAM
SAINT-GOBAIN PAM
201-203 Cach Mang Thang 8, Ward 4 - District 3
HO CHI MINH CITY - Vietnam
Phone: +84 8 39 30 72 74

POLAND
SAINT-GOBAIN CONSTRUCTION PRODUCTS POLSKA
SP Z.O.O - PAM Business Unit
UI. Cybernetyki 21
PL-02-677 WARSZAWA - Poland
Phone: + 48 22 751 41 72

- 03/2012 - AEP-CAT-68F - cover: Jorge Moro - Fotolia.com

ARGENTINA

You might also like