CLCP Euro - Commercial May 09: Quick Selection Procedure
CLCP Euro - Commercial May 09: Quick Selection Procedure
May 09
003
004
006
008
010
012
014
016
020
025
030
035
040
045
050
060
065
070
080
085
090
095
Coil
Face
Area
m2
0.2
0.4
0.6
0.7
0.9
1.6
1.4
1.6
1.9
2.4
2.9
3.4
4.0
4.5
5.0
5.9
6.6
7.2
7.8
8.4
9.1
9.7
Airflow At
2.55m/s
Face
Velocity
m3 / s
0.6
1.0
1.5
1.9
2.3
3.0
3.6
4.1
5.0
6.2
7.4
8.7
10.1
11.5
12.9
15.2
16.8
18.4
20.0
21.6
23.2
23.2
Total
Cooling
Capacity
External
Static
Pressure
kW
10.7
21.0
24.8
36.9
39.7
59.1
76.3
81.3
106.2
132.0
156.3
191.7
228.5
265.6
302.8
358.3
353.9
396.0
438.7
481.6
524.5
543.7
Pa
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
Unit Dimension
(Fan + Coil + Flat Filter)
Width
mm
748
1058
1368
1678
1368
1678
1988
1678
1988
1988
1988
2298
2608
2918
3228
3228
3538
3848
4158
4468
4778
5088
Height
mm
868
868
868
868
1178
1178
1178
1488
1488
1798
2108
2108
2108
2108
2108
2418
2418
2418
2418
2418
2418
2418
Length
mm
1273
1273
1273
1273
1428
1428
1428
1428
1428
1583
1893
1893
2048
2048
2203
2203
2203
2951
2951
2951
2951
2951
Unit
Weight
Cooling Coil
Water
Pressure
kg
196
244
329
370
410
485
606
667
802
938
1067
1199
1448
1545
1776
1931
2200
2318
2468
2654
2767
2868
kPa
2.0
5.8
4.3
10.2
4.2
9.9
17.5
9.5
17.2
20.9
19.2
30.6
45.8
65.1
88.6
78.1
23.0
29.5
37.0
45.4
55.0
60.5
Water
Flow
Rate
Drop
L/s
0.5
0.9
1.1
1.6
1.7
2.6
3.3
3.5
4.6
5.7
6.8
8.3
9.9
11.5
13.1
15.5
15.3
17.2
19.0
20.9
22.7
23.6
Motor
Installed
Power
kW
1.1
2.2
3.0
3.0
3.7
3.7
5.5
5.5
7.5
7.5
11.0
11.0
15.0
15.0
18.5
22.0
30.0
30.0
30.0
30.0
30.0
30.0
Note:
1. Cooling capacities are based on EDB 26.70C / EWB 19.40C and EWT 6.70C / LWT 12.20C.
2. Unit dimension and weight includes forward curved fan section, 4row 120fpf coil (1/2inch cu tube) section and flat filter section (with filter media).
3. All dimensions and weights above are based on 50mm casing design.
Mechanical Specifications
Casing
Casing shall be pentapost perimeter frame with a modular system
based on standardized double wall panels.
Casing strength shall be designed and certified to European
Standard EN 1886: 1998, Casing Strength Class 2A.
Casing air leakage rate shall be certified to Eurovent Casing Air
Leakage Class B.
Panel shall be attached to the frame through a self-locking
mechanism represented by a wedge and frame, exerting
pressure evenly onto the panel and the seal attached to the frame,
and hence a better air tight cabinet construction.
Removal of any of the panels for any maintenance or repair works,
must not affect the structural integrity of the unit.
The casing construction shall incorporate thermal break feature in
the panel design with T2 Thermal transmittance and TB2 Thermal
bridging factor certified to EN1886: 1998
The whole unit shall be mounted on a galvanized steel base rail
for ease of shipping and handling.
Panel
Panels shall be 25/50mm thick with injected polyurethane foam
insulation for a rigid construction.
The panel insulation material shall have a heat transfer K value of
0.02w/mK.
The outer wall shall be galvanized steel painted with baked
polyester powder paint that is resistant to nicks and scratch and
allow for easy cleaning. The inner wall shall be galvanized steel.
The door construction shall consist of a door panel that
compresses with gasket onto a rigid fram
Opening or closing of the door shall not affect the structural
integrity of the unit.
Fan Section
Supply fan shall be certified as per AMCA 210 and AMCA 300
Standards.
All fans impellers are statically and dynamically balanced to ISO
1940.
The entire fan/motor/drives assembly shall be mounted on a
common framework and isolated from the unit by rubber-in-shear
or spring isolators. The fan discharge shall be isolated from the
casing by a vibration absorbing or flexible duct.
Fan shall be equipped with bearings with an L-50 life of 200,000
hours.
Motors shall be totally enclosed fan-cooled (TEFC) with IP55
protection with class F insulation 40 degree C.
Coil Section
Coils performance/selection shall be rated in accordance with ARI
Standard 410, and certified to EN 1886: 1998
Cooling coils shall be cartridge type mounted on steel channel for
easy removal when required.
Coil casing shall be galvanized steel with drain holes in the bottom
channels to ensure condensate drainage.
Coil tubes shall be copper and mechanically expanded into
aluminum plate fins. No soldering or tinning shall be used in the
bonding process.
The fins shall be sine-wave design with slits for better heat
transfer efficiency and moisture carry-over limit performance.
All coils are proof and leak tested at 375
psig.
Dual pitched sloping drain pan shall beinstalled under the coil to
ensure total removal of condensate.
In case of stacked coils, an intermediate drain pan shall be
installed between the coils to drain condensate to the main drain
pan without flooding the lower coil and passing condensate
through the air of the lower coil.
Table B
589
648
648
702
702
4 - 22
30 - 45
5.5 - 22
30 - 45
7.5 - 22
30 - 45
7.5 - 22
30 - 75
7.5 - 22
30 - 75
F/BDB 710
F/BDB 710
F/BDB 800
F/BDB 800
F/BDB 900
035(1412)
040(1612)
045(1812)
050(2012)
060(2014)
065(2214)
F/BDB 1000
589
4 - 22
30 - 45
F/BDB 630
030(1212)
095(3214)
540
4 - 22
30 - 45
F/BDB 560
025(1210)
F/BDB 1000
446
2.2 - 7.5
11 - 15
18.5 - 30
F/BDB 560
020(1208)
F/BDB 1000
446
2.2 - 7.5
11 - 15
18.5 - 30
F/BDB 500
016(1008)
090(3014)
387
2.2 - 7.5
11 - 18.5
F/BDB 450
014(1206)
085(2814)
365
1.5 - 7.5
11 - 18.5
F/BDB 400
012(1006)
F/BDB 900
337
1.5 - 7.5
11 - 15
F/BDB 400
010(0806)
F/BDB 1000
337
1.1 - 7.5
11 - 15
F/BDB 315
008(1004)
070(2414)
283
006(0804)
080(2614)
194
F/BDB 225
11 - 75
11 - 75
7.5 - 75
7.5 - 75
0.37 - 3
732
732
732
732
246
236
221
004(0604)
0.18 - 3
F/BDB 200
207
207
207
207
198
198
201
201
198
198
196
145
145
117
117
116
116
115
46
116
115
115
102
102
102
102
100
100
100
100
100
100
100
100
100
100
99
97
97
96
98
97
99
100
627
627
627
627
604
604
547
547
489
489
443
401
401
368
345
318
318
264
247
227
217
185
FAN ARR
J
ARR1 ARR2 ARR3 ARR4
003(0404)
MOTOR
KW
FAN
MODEL
1860
1860
1860
1860
1550
1860
1550
1860
1550
1705
1550
1705
1395
1550
1395
1550
1240
1550
1085
1240
1550
1085
1240
1550
930
1085
930
1395
930
1085
930
1085
930
1085
775
775
775
775
2015
2015
2015
2015
1860
2015
1860
2015
1705
1860
1705
1860
1705
1705
1550
1705
1395
1705
1395
1550
1705
1395
1550
1705
1240
1395
1240
1550
1085
1240
1085
1240
930
1240
930
930
775
775
FAN SECTION
L1
ARR1,2 ARR3,4
986
831
826
671
602
602
561
406
294
276
276
266
227
349
209
161
409
336
199
155
170
MOTOR ACCESS
RH
LH
WL WR WL WR
916
916
818
732
732
656
586
524
524
422
378
340
307
274
1284 1284
1284 1284
1284 1284
1284 1284
1148 1148
1148 1148
1024 1024
1024 1024
916
916
818
732
732
656
586
524
524
422
378
340
307
274
1085
1085
1085
930
930
775
775
620
620
620
465
465
465
310
310
310
310
310
310
310
310
310
FLAT FILTER
W/MIX.SECT.
L4
1628
1318
1008
698
779
779
779
469
469
469
469
1128 1938
1128 1628
1128 1318
818
818
818
818
25mm CASING
1678
1368
1058
748
804
804
804
494
494
494
494
1860 310
1550 310
1240 310
1550 310
1240 310
930 310
620 310
DW DH
DAMPER
1178 1988
1178 1678
1178 1368
868
868
868
868
50mm CASING