2GIG CT100 User Guide
2GIG CT100 User Guide
top cover
Reset
button
Wire
terminals
Power Grid
status
indicator
MENU
button
Mode
button
HVAC
selections
switches
Touch screen
bottom
cover
ENGLISH
PG
HOME Screen
Control Screens
Before you operate the CT100 please get familiar with these basic control screens. All the CT100
functions are accessed through these screens: HOME, MENU, and MANUAL. The CT100 touch
screen technology allows you to select (by touching) an item and change it using the +/- arrows or the
time arrows.
The HOME screen is displayed
when the unit is operating. Touching
Fan
Status
AUTO
RADIO
Temperature
Controls
LINK
HEAT
TARGET TEMP
Target
Temperature
Radio
Indicator
Thermostat
Mode
MENU Screen The MENU screen is the gateway to many functions or settings of the
CT100. It is displayed when you press the MENU button. [See page 10 for details]
Differential to set
RECOVERY set
Set Time
for 2nd Stage start.
FAST or ECON
Touch this area to set
the time of day.
Left arrow goes back,
ECON RECOVERY DIFF
right arrow goes forward.
FAST RECOVERY SWING
Temperature
Swing set
Return
to HOME
screen.
F
C
RADIO
2
RADIO icon
Shows radio status
and connection
Chirp set
Touch this to turn the
audible chirp on or off.
LINK
MATE
HVAC
SETUP
Lock Program
Touch for 5 sec
to lock or unlock.
CALIBRATE ON
.
Calibration
control
Use this to calibrate your
LCD display match to
another thermometer
Set C - F
Touch this
to set temp
display units
o
HVAC SETUP
Touch this in OFF mode to
configure the unit to work with
your HVAC system.
PG
PG
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your CT100s operation. From the HOME screen, touch the main temperature
display to use this screen. [See page 13 for details]
AUTO
EMER
HEAT
Room
Temperature
Target
Temperature
Initial Settings
Press MENU to access the following commands (from HOME screen).
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until
it displays the current time. Touch and hold for faster setting.
Set oF-oC display
Touch the oF and it will toggle to oC.
Backward Forward
PG
PG
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the CT100 setting and the room temperature required before the heating or cooling system
will turn onSwing range: 0.5 to 4.0F (.25 to 2C). For example, if SWING is set to 2.0 F and the
CT100 is set to 70F Target Temperature, the heat cycle will start when room temperature drops to
68F. Similarly, the cooling system will start when the room temperature increases to 72F. The HVAC
then runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5 to 4.0F (.25 to 2C).
The HVAC will run more frequently at 0.5F and less at 4.0F. Default is 1F.
Touch
Chirp set - Touch this to turn the audible chirp sound on or off.
F
C
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily
override the CT100 target with the +/- buttons only. (1 bar)
For FULL lock : Touch the (1 bar) icon again for 5 seconds to go to full lock. No changes can be
made in full lock (2 bars). Once locked, the CT100 will respond just to MENU.
To UNLOCK , Press MENU.
Touch and hold icon for 5 seconds for 2 bars (if not there already).
Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate.
Touch
PG
PG
CALIBRATE
DIFF (Used for multiple stage systems only, not on screen for single stage)
The differential is the number of degrees between the room temperature and the Target Temperature
at which the 2nd stage will be used. Default is 2F , range is 2F to 6F (1- 3C).
Touch MENU and then DIFF. Use the arrows to set the DIFF.
Recommend 2F for very cold climates and the 6F for warm climates.
PG
PG
Other Functions
MODE Button
The mode button sets the CT100 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the
next mode. If the CT100 is in OFF and you want to return to the mode you were previously in, touch
the OFF indicator on screen.
FAN Button
The fan control is normally in AUTO mode, meaning that the fan operates automatically with the
HVAC system and the thermostat. When the fan button is pressed the fan goes ON; the fan will run
continuously in this manual override until switched back to AUTO by pressing the FAN button again.
[NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.]
RESET button The RESET button re-boots the CT100 processor. It does not effect the target
temperatures that have been stored in permanent memory.
Compressor Protection The CT100 has a minimum cycle time of 4 minutes to protect your
compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and
A/C during this time and the compressor will not come on until the 4 minute delay is over.
10
Communicating Thermostat
The CT100 has a built in Z-Wave radio. This allows your thermostat to
communicate with other systems.
Network INCLUSION
1. Set your primary controller to INCLUDE mode, to add the thermostat as a node on your network
(see your specific controllers User Manual for detailed instructions.)
2. Press and release the MENU button on the thermostat.
3. Press the MATE button - This will bring you to the network screen and a large r1 will be displayed.
4. Press the MATE button, this will initiate the mating process. When a device has joined a network
the word LINK will appear under the radio tower.
Your controller will indicate the thermostat was successfully added to its network (see your specific
controllers User Manual for details).
Network EXCLUSION
1. Set your primary controller to EXCLUDE mode, to remove the thermostat as a node on your
network (see your specific controllers User Manual for detailed instructions.)
2. Press and release the MENU button on the thermostat.
3. Press the MATE button - This will bring you to the network screen and a large r1 will be displayed.
4. Press the MATE button, this will initiate the mating process. When a device been removed from a
network the word LINK below the radio tower will disappear.
Your controller will indicate the thermostat was successfully removed from its network (see your
specific controllers User Manual for details).
PG
11
PG
Caution
12
PG
13
PG
14
PG
15
PG
16
PG
17