Utilities Questionaire
Utilities Questionaire
BRANCH VENT
TYPE OF VENTS
A vent connecting one or more individual vents with a vent stack or stack vent
CIRCUIT VENT
A branch vent that serves two or more traps and extends from in front of the last fixture
connection of a horizontal branch to the vent stack
COMMON VENT
A vent connecting at the junction of two fixture drains and serving as a vent for both fixtures
A single vent that ventiliates multiple traps, in the case of back to back fixture
CONTINOUS VENT
A vertical vent that is the continuation of the drain to which the vents connect
DRY VENT
A vent that does not serve as drain and is located where if is not exposed to back up
of waste from a drainage pipe
DUAL VENT
GROUP VENT
A branch vents that performs its functions for two or more traps
INDIVIDUAL VENT
A pipe installed to vent, a fixture trap and w/c connects with the vent system above the fixture
served or terminates in the open air
A circuit vent which loop backs to connect with a stack vent instead of a vent stack
Any vent connecting a horizontal branch or fixture drain with the stack vent of the
originating waste or soil stack
LOCAL VENT
Is a pipe on the fixture side of the trap through which vapor or foul air is removed
from a room fixture
MAIN VENT
The principal artery of the venting system to which vent branches may be connected
RELIEF VENT
A vent installed so as to permit additional circulation of air between the drainage and vent
systems where the drainage systems might otherwise be air bound
UNIT VENT
An arrangement of venting so installed that that one vent pipe will serve two traps
STACK VENT
The extension of a soil or waste stack above the highest horizontal drain connected to the
stack horizontal drain, the uppermost end above the roof
WET VENT
YOKE VENT
A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of
preventing pressure changes in the stack
NATIONAL PLUMBING CODE OF THE PHILIPPINES
Is the flow of water or other liquids, mixtures or substances into the distributing pipes of a
supply of water from any source other than its intended source
Is the backflow of used, contaminated or polluted water from a plumbing
fixture due to negative pressure
Refers to any group of two or more similar adjacent fixtures which discharge into a common
horizontal waste or soil branch
A flange that is not drilled
A flange that closes the end of a pipe line used to discharge water
Is plugging an opening with oakum, lead or other materials
A short internally threaded section of pipe, used to join two pipes of conduits
Used to connect the two ends of two pipes, neither of which can be turned
A short length of pipe with threads at each end; used to join couplings or fittings
Is the extended portion of a pipe that is closed at one end to which no connections are made
on the extended portion
The length along the center of the pipe and fitting
Includes all piping within public or private which conveys sewage, rain water or often liquid waste
to a legal point of disposal but does not include the main of a public sewer system or private or
or public sewerage treatment
Is a pipe connecting several fixtures
Is a device located at the bottom of the tank for the purpose of flushing water closets and
and similar fixture
A metallic sleeve, join to an opening of pipe, into which a plug is screwed
that can be removed for the purpose of cleaning
Is the lowest portion of the inside of any pipe or conduit that is not vertical
Includes water supply and distribution pipe; plumbing fixture and traps, soil
waste and vent pipes; house drain and house sewers including their respective connections
Installation of all parts of the plumbing system which can be completed prior to the installation
of fixtures
A wye connections used on fire lines so that two lines of hose maybe connected to the hydrant
or to the same nozzle
Is any pipe which conveys the discharge of water closets of fixture having
similar function w/ or w/o the discharge of other fixtures to the building drain
Is the maximum vertical depth of liquid that a trap will retain measure between the crown weir
and the top of the dip of the trap
BACKFLOW
BACK SIPHONAGE
BATTERY OF FIXTURE
BLANK FLANGE
BLIND FLANGE
CAULKING
COUPLING
UNION
NIPPLE
DEAD END
DEVELOPED LENGTH
DRAINAGE SYSTEM
FIXTURE BRANCH
FLOOD LEVEL
FERRULE
INVERT
PLUMBING SYSTEM
ROUGH IN
SIAMESE CONNECTIONS
SOIL PIPE
TRAP SEAL
WATER RESERVOIR
SHOCK RELIEF AND EXPANSION
CHAMBER
50 FEET OR MORE
2 PERCENT
CULVERT
BLACK WATER
RECESSED
WHITE
BLACK
TRAP OR WATER SEAL
2.50 M
COMPRESSION VALVE
CISTERN
OVERHEAD STORM DRAIN
PRESSURE COCK
PRESSURE REDUCING VALVE
UNION PATENT
FLUSHOMETER
CORPORATION STOP
AIR TRAP
ABSORPTION TRENCH
ILLUMINATION
CATCH BASIN
WYE FITTING
1 1/2"
150mm DIAMETER
1 1/2"
2"
1 1/2"
1 1/2"
1 1/2"
1 1/2"
1 1/4"
2"
1 1/4"
1 1/2"
1 1/2"
2'
1 1/2"
1 1/4"
2"
3"
3"
1 1/2"
2"
2"
1 1/4"
3"
SIPHON-VORTEX
SIPHON-JET
REVERSE TRAP
WASH DOWN
BLOW OUT
WALL HUNG
THROUGH
PEDESTAL
STALL
BIDET
19.05mm or 3/4"
46 mm.
122mm
61 mm.
122 mm
5 FEET
1/4" BEND ?
51mm or 2"
64mm or 2 1/2"
(PLUMBING)
Install to be able to meet the water requirements during peak demands from a low yielding
water well
The device being used to eliminate the noise cause by water hammer
The location of water well to nearest septic vault
Slope of house sewer connected from the building to the main sewer
A passage under a road, embankment or canal which allow for the flow of water
The third kind of water after the storm water and area water
The type of bathtub oher than sunken, square, free standing
Color coding of high pressure steam
Color coding for fuel oil division
The water column that seals the escape of unhealthy gases in the sanitary drainage system
Service drop conductor clearance over the roof
A valve which in the water flow is shut off by a flat disk that is screwed down onto its seat
An underground tank reservoir to store water
Another classification of storm drain, besides from inside drain and outside drain
Tap used in high pressure water system with an interval valve to control the flow of water
A valve which maintains uniform pressure on its outlet side regardless of its pressure fluctuations
on the inlet side above the pressure level
A pipe fitting within the interconnection of pipes for the purpose of easy dismantling of
the connection when needed
A device that discharge a predetermined volume of water to fixture for flushing purposes and
is activated by direct water pressure
Another name for corporation cock
A U-shaped pipe filled with water and located beneath the plumbing fixtures
to form a seal against the passages of gases and odors
A trench containing course aggregate and a distribution tile pipe through which septic tank
effluent may flow covered with earth
The luminous flux density incident on a surface
An underground structure for drainage into which water from the roof or floor will drain through
sewer
A type of fitting for yoke bent
Minimum discharge pipe and fitting for bath tub
Minimum size of building sewer; it should not be less than the building drain
TRAP SIZES OF FIXTURES
BATH FOOT
BATH SHOWER STALL
BATH SITZ
BATH TUB
BIDETS
COMBINATION FIXTURE
DRINKING FOUNTAIN
FLOOR DRAIN
FOUNTAIN CUPSIDERS
LAUNDRY TRAYS
SINKS (DISHWASHER)
SINKS (HOTEL OR PUBLIC)
SINKS (KITCHEN OR RESIDENCE)
SINKS (SMALL PANTRY OR BAR)
SLOP SINKS (ORDINARY)
SLOP SINKS (WITH COMBINE TRAP)
URINAL (PEDESTAL)
URINALS (LIP)
URINALS (STALL)
URINALS (THROUGH)
WASH BASIN (LAVATORIES)
WATER CLOSETS
TYPES OF WATER CLOSETS
Quiet, extermely sanitary. Like the siphon jet but having the flushing water directed through the
rim to create a vortex that scours the bowl
Sanitary, efficient very quiet. A toilet bowl into which the flushing water enters through the rim and
siphonic action initiated by a water jet draws the contents of the bowl through the trapway
Moderately noisy. Similar to siphon jet except that trap passageway and water surface area
are smaller
Minimum cost. Least efficient subject to clogging, noisy. Simple washout and emptying through
small irregular passageway, prohibited by some health codes
Noisy but highly efficient. Strong jet into leg forces contents out
URINALS
A basin like fixture design to be struddled for bathing the genitals and posterior parts of the body
NOTES
No building supply pipe shall be less than WHAT size in diameter
Minimum height of Fire Service Connection from the grade/floor
Maximum height of Fire Service Connection from the grade/floor
Minimum height of Dry Standpipe Outlet from the floor line
Maximum height of Dry Standpipe Outlet from the floor line
Considered extension of bulding drain outside the building wall
Fitting for base or soil stack and building drain
Wet standpipe for a riser not more than 15m
Wet standpipe for riser more than 15m
4"
6"
RATIO OF 1:25
RATIO OF 1:30
RATIO OF 1:75
RATIO OF 1:75
RATIO OF 1:5
4 CLOSETS
3 HEADS
GI PIPE SIZES
1/2", 3/4", 1", 1 1/4", 1 1/2", 2, 2 1/2"
3", 4", 6", 8", 10", 12"
AIR CONDITIONER
BUGLARS AND PROWLERS
AIR DUCT
DRAUGHT OR DRAFT
4 STOREY
BLACK
DUMBWAITER
HUMIDIFIER
50 GALS.
THERMOSTAT
BULLDOZER
ACOUSTICAL LAY IN PANEL
DECIBEL
135-197 F
REAR OR TOP
SOUND ABSORPTION
SOUND INSULATION
LUX
WATER TABLE
AIR HANDLING UNIT
TRAVEL TIME
CONCRETE CASING
CREEP
TRAVEL TIME
FREIGHT ELEVATOR
BUFFER
PIT
WINDING DRUM MACHINE
GUIDE RAILS
600mm
FOR REPAIR AND INSPECTION
2 HOISTWAYS
4 ELEVATORS
3 HOISTWAYS
2 HOISTWAYS
30mm
OVER LOAD RELAY AND
REVERSE POLARITY RELAY
(MECHANICAL)
An apparatus that can heat, cool, clean and circulate air
They were deter to the intrusion alarm system in residential signal system
An air passage usually formed in sheet metal with insulation for ventilating on a building
The current of air or gases
Requirement for a dry standpipe
Color coding of piping for fuel oil division
A hoisting and lowering mechanism with a building equipped with relatively small car
excusively for carrying materials
The device for maintaining desirable humidity conditons in the air supplied
The average consumption of water per capita
An automatic control of the operation of heating or cooling device responding to changes of
temperature of the space
A tractor equipped with the blade attached by arms and bolted to its end, used in piling earth
The acoustical ceiling board design to be laid in an exposed grid suspension system
The total sound units provided by a given material
Heat rating for a fixed temperature heat detector
Fire tube boliers shall be provide with sufficient room for removal or replacement of tube
either from these places
The process of dissipating sound energy by converting it to heat
The system of deadening sound materials to wall, ceiling, floors to prevent sound from passing
through the members into adjoining room
The illuminance produce by luminous flux of the one lumen distributed uniformly over a one
square meter surface
Level of subterrenean water
Package assembly of air conditioning components which provides for the treatment of the air
before it is distributed to an air conditioned space
This is the criteria in selection of an elevator other than interval and average waiting time
Protection of PVC pipe underground
Reflection of sound from curve surface
ESCALATOR AND ELEVATOR
The criteria in the selection of an elevator other than interval and average waiting time
Type of conveyor that transport packages equipment crates
Important element of an elevator below the first level floor line that absorbs and minimize
building shocks to the car
That portion of the hoistway in the elevator extending from the threshold level of the lowest landing
floor of the hoistway
A geared drive machine in which the suspension ropes are fastened to and wind on a drum
Vertical tracks that serves as a guide for the car and the counterweight
MECHANICAL REGULATIONS
ELEVATOR
Car pit clearance depth from the bottom of the car
When machine room or penthouse is provided at the top of the hoistway, it shall have
a sufficient room for this
When 4 or more elevator serve all or the same portion of the bulding
Shalll be located in any one hoistway
Minimum number of hoisting ropes for traction elevators
Minimum number of hoisting ropes for drum type elevators
Minimum diameter of hoisting and counterweight ropes
Provision for all elevators
ESCALATOR
Minimum angle of inclination of an escalator
Minimum width of balustrade
Maximum width of balustrade
Maximum width of the steps
Kind of glass required in an escalator's balustrade
Maximum rated speed measured along the angle of inclination
BOILERS
R.C CONCRETE OR MASONRY
Provision for boiler rooms inside the building
3.00 mts. FROM OUTSIDE WALL
Minimum distance if the building is not made of fire resistive materials
1 meter
No part of the boiler shall be closer to this from the wall
5.00 mts
Distance of the smokestacks above the building within 50 mts. radius
2 CHECK VALVES
Provision between any feed pump and the boiler in addition to the regular shut-off valve
NON RETURN OR SHUT OFF VALVE Provision when two or more boilers are connected in parallel
ONE SAFETY VALVE
Provision of every boiler
TWO SAFETY VALVE
Provision for boilers having generating capacity exceeding 907 kg/hr
15 DAYS
Notification in writing in advance for boiler's inspection
REFRIGERATION AND AIR CONDITIONING
68deg-74deg F
Temperature and humidity of the air to be used for comfortable cooling
35 degrees
558 mm
1.20 m
330 mm
TEMPERED TYPE GLASS
38 mpm
CAGE
CIRCUIT BREAKER
CONDUCTOR
CONTROLLER
CORONA
CUT OUT BOX
DEMAND FACTOR
DEVICE
DUCT
ELECTRIC MOTOR
FEEDERS
FOOTCANDLE
FUSE
GENERAL LIGHTING
ILLUMINATION
KNIFE SWITCH
LAMP
LAMPHOLDER
LIGHT
LIGHTNING ARRESTER
LIGHTNING SURGE
LINE TAP
LOAD FACTOR
LUMEN
LUX
OUTLET
OUTLET BOX
PEAK LOAD
PENDENT
PILOT WIRE
PULLBOX
RACEWAY
RECEPTACLE
RIGID METAL CONDUIT
ROSETTE
SERVICE DROP
SERVICE RACEWAY
SUBMARINE CABLE
SURGE
5.5 mm2
HERTZ
PHON
REVERBERATION
WAVELENGTH
SOUND DIFFRACTION
SOUND
PURE TONE
CANDELA
LUMINAIRE
LAMBERT
LUX
FOOT CANDLE
LUMINOUS FLUX
IMPEDANCE
CONDUCTANCE
SOUND INTENSITY
ACCENT LIGTHING
HPS LAMP
SINGLE PHASE TO SUPPLY
120 V LIGHTING LOAD
This is used to supply a single phase lighting load and three phase
power load simultaneously
Often it is desirable to increase the voltage of a circuit form a 2400 to 4160 volts to
increase its potential capacity
This connection is similar to the delta-delta bank with only the primary connection changed
The primary neutral should not be grounded or tied into the system neutral, since a single
phase ground fault may result in extensive blowing of fuses throughout the system
This connection requires special watt-hour metering
OPEN Y DELTA
When operating Y delta and one service is disabled, service maybe maintained at reduced load
The single phase lighting load is all on one phase resulting in unblanced primary currents
in any one bank
The primary voltage was increased from 2400 to 4160 volts to increase the potential
capacity of the system
When the ratio of transformation from the primary to secondary voltage is small,
the most economical way of stepping down the voltage
SCOTT CONNECTION
3PHASE TO 2PHASE
In some localities two phase power is required from three phase system
SCOTT CONNECTED
2PHASE TO 3PHASE
T
TW
UF
FEPW
RH
RHW
RUH
THW
THWN
XHHW
BX
THHN
PE
SA
AVA
Thermoplastic
Moisture Temperature Resistant
Underground Feeder
Flourinated Ethylene Propylene Moisture Resistant
Heat Resitant Rubber
Heat and Moisture Resistant Rubber
Heat Resistant Latex Rubber
Moisture and Heat Resistant Thermoplastic
Heat and Moisture Resistant Thermoplstic with Nylon
Moisture and Heat Resistant Cross Link Polymer
Armored Cable
THERMOPLASTIC HEAT RESISTANT
POLYETHELENE
SILICON ASBESTOS
ASBESTOS AND VARNISH CAMBRIC
HEAT DETECTOR
Use low melting point solders or metal the expand when exposed to heat to detect fire
135deg-197deg F
Use of the scattering of light by smoke into view of photo cell through incandescent or diode
It responds to the high-frequency radiant energy from flames. Alarm is only triggered when
IR energy flickers at rate which is chracteristics of flame
Uses the interruption of small current flow between electrodes by smoke in ionized sampling
chamber to detect fire
TYPES OF CABLE
Fabricated assembly of insulated conductors enclosed in flexible metal
sheath. It is used both on exposed and concealed work
FIXED TEMPERATURE
HEAT DETECTOR
PHOTO ELECTRIC DETECTOR
INFRARED FLAME DETECTOR
IONIZATION SMOKE HEAT
DETECTOR
ARMOR CABLE (AC)
TELECOMMUNICATION SYSTEM
DRY STANDPIPE
A fireline system without a constant water supply and is equipped with a fire service
inlet and outlet connection installed exclusively for the use of Fire Service
Which poor design in the plumbing system causes water supply drop
when the fixture is simultaneously opened?
1 "
1 "
64mm or 2 "
64mm or 2 "
Not needed in sizing the vent pipe for individual branch and circuit vent
based on the total linear footage of the pipe making up the vent?
A hot and cold water supply pipes, where it is mix manually in desired water temperature
temperature and direct the mixed water either at the shower head or at the fooe spout
BALL VALVE
Principle where a single lever valve used in kitchen sink and lavatory, they are
beautiful and maintenance free
Minimum water delivery in liters per minute for an outlet of a wet standpipe
at a residual pressure or 1.8 kilos per sq.mts
ELBOW REDUCER
A female GI threaded pipe reducer fitting use to connect a reducing branch pipe at an angle
CIRCUIT VENT
Type of vent applied on installations with multi branch interval where the vertical vent pipe
takes off in front of the first fixture and connects to a main vent stack
REVERSE OSMOSIS
Stage in water purification which removes mineral deposits, slats, heavy metal, totally dissolves
solids while some useful minerals are retained
FIXED TEMPERATURE
HEAT DETECTOR
Fire detector installed in a fire alarm system, which uses low melting point
solders or metals that expand when exposed to heat to detect a fire, 135deg-197deg F
COUPLING
GI fitting to join two threaded fittings as close as possible but not exceeding three inches
PRESSURE REGULATOR
A device used to control an incoming high water pressure into the water distribution system
by mechanical means so as to bring it to a working pressure of 80 psi
SUBMERSIBLE PUMP
jet,jack,reciprocating
A type of pump for driven well from 150 to 200 ft which work by a principle of venturi where
water of high pressure is pump into the well to draw water upwards through the return pipe
Which of the following does not require the installation of the cleanout?
5"
Which is not a standard size of GI pipe for water supply? 2 1/2", 3",4",5"
Term used for pipe extension of not more than 2 feet in length install in
any stack or branch of a plumbing rough in for the purpose of future trap
CHECK VALVE
120 LITERS
For cold water, a family members of 12 needs a 3.6 cu.mts. of cold water.
What is the maximum hot water probable hour demand?
110 100 120 140 liters
AUTOMATED RETRACTABLE
PILLAR SYSTEM
Parking management system for two types of vehicular deterrent either articulated arm type
or straight beam type. It can be activated by means of radio frequency remote control, push
push button switch, photocell, magnetic loop or acces control
THREE FIXTURES
DRY STANDPIPE
POLTYBUTELENE PIPE
AND FITTINGS
Pipes and fittings which can exclusively be used for cold water lines for
potable main distribution water service, sprinkler and irrigation system. It
could be ", ", 1", 1 ", 1 " and 2"
Orange or brown in color with sizes of 4" and 3 meter in lengths of pipes
and fittings, ASTM 2729 standards
ASBESTOS PIPE
Least popular and not recommended use as potable water distribution pipe
GATE VALVE
64mm or 2 1/2"
Minimum size of wet standpipe for a riser more than 15 meters from the source
61 cms
AIR CHAMBER
Spacing provided for elevator with single bank in a non residential building
Recording calls even when car is in use. It answer calls starting from the
highest and so on while descending
UP COLLECTIVE CONTROL
GOVERNOR
safety gear, safety shoe
magnetic break
Safety device of a passenger elevator which activates if the car travels faster
than its rated speed by grasping the guide rail to stop the car safely
ESCALATOR'S PART
1120;980;800;760
1150;1100;1000;900
ADJUSTABLE LOCKING
DAMPERS
AT THE ESCALATOR
MACHINE ROOM
This is a guide for the initial estimate per Ton of Refrigeration per sq.mts. of a standard
room of normal condition without external solar heat gain and excessive internal heat gain
International Standard and EN 81.1 Code in designing a machine room
PIPING OR DUCT BELONGING TO OTHER SYSTEM SHOULD NOT RUN
THROUGH THE MACHINE ROOM
OPENING BETWEEN HE MACHINE ROOM AND THE SHAFT MUST BE FULLY OPENED
TO ALLOW EASY ACCESS
VENTILATION MUST BE SUFFICIENT IN ORDER TO MAINTAIN INDOOR TEMPERATURE
OF 5 TO 40 DEGREES
ONLY HOIST MACHINE MOTOR ASSEMBLY, CONTROL PANEL AND AUXILLARY
EQUIPMENT FOR FIRE FIGHTING ARE ALLOWED INSIDE
STANDARD INSTALLATION OF ESCALATOR NOT EXCEEDING 4.50 MTS./ TRUSS
THE TOP CHORD OF THE TRUSS IS WITH A STEEL ANGLE SUPERIMPOSED
ON THE BUILDING'S STRUCTURAL BEAM
COUNTERWEIGHT BUFFER
Safety device caused by insufficient water flow on heater when brown out
EXPANDED POLYTHELYNE
FOAM INSULATION
Vital part of Solar Water heater to keep the heat in and cold out
KNOCKDOWN BY MAJOR
COMPONENT PART
COOLING TOWER
RH
METAL HALIDE
Light source used in lighting fixtures best specified in areas such as those requiring high illumination
levels for detailed work such as needle work
TW
ILLUMINATED SWITCH
Type of switch where pilot light inside a lit to guide the person inside
85 amperes
DRAWINGS
Main power supply and wiring system for 110/220 volt line; which wiring diagram fits (drawing)
7500mm to 9000mm
5000mm to 6000mm
10000mm to 12000mm
6000mm to 7600mm
What is the maximum horizontal range between two or more air terminal for lightning
arrest for an effective disaster prevention in building
550mm; 700mm
600mm; 850mm
An air terminal for lighting arrest is distanced at 7600mm. What must be the least height of the
air terminal above the building part being protected for disaster prevention
15 amperes
PVC IS ALLOWED FOR AS LONG AS Best suited for Rigid Nonmetallic Conduit like PVC for underground installation in buildings
BOTH BURIAL DEPTH OF NO LESS
460mm AND CONCRETE
ENCASEMENT IS PROVIDED
ULTRASONIC
SABINS
First defense method from external noise by site selection and site
planning for quiet internal acoustic environment
The effective method can be employed to reduce direct noise, which is transmitted airborne,
for noise reduction within a space
SOUND TRAVELS SLIGHTLY LOWERThis does not describe the velocity of sound correctly
(FASTER)MOIST AIR THAN IN
DRY AIR
7,380 fps
INTENSITY
VENT PIPE
It ventilates a house drainage system and prevent siphonage and back pressure
3/8"
6 FEET
The maximum horizontal developed length between the trap seal and the
vertical vent inlet at the trap
Combination fitting between the vertical waste branch and the horizontal waste branch
COUPLING REDUCER
A female GI pipe reducer fitting used in straight connection, both are threaded inside
CIRCUIT VENT
A vent use in battery of plumbing fixture where the vent is installed in front
of the last fixture of the battery
JET, SUBMERSIBLE
TURBINE, SUMP
A water pump for a 200ft driven well to deliver 10gpm against 200ft. It is
located at the surface
RECIPROCATING
CENTRIFUGAL, PISTON, TURBINE
A pump motor installed on the surface attached to a lift and push a rod to
activate a submerge piston
RECIPROCATING
CENTRIFUGAL, PISTON, TURBINE
A pump with an impeller enclose in a housing coupled with the pump motor
Its principle is to add a velocity to already flowing liquid
CENTRIFUGAL, SUBMERSIBLE
JET, TURBINE
A pump which delivers high water discharge with high water pressure drawn
from a shallow source like cistern, best suited as fire or transfer pump.
The motor is placed at the surface with shaft to turn the impellers below
46 mm
BELL REDUCER
POLYETHELENE PIPE
PE
General term for hot or cold water pipes containing portable water supplying
different plumbing fixture
Where are dampers install to regulate the amount of cool air fo an even
distribution of outlets
Rating index of an air conditioning system which rate the number for the unit
of BTU heat moved per watt of electrical input energy
TONS OF REFRIGERATION
BOTTOM SPROCKET
GEARED HOIST
HELICAL GEARED MOTOR WITH
TRANSMISSION REDUCTION
CONTROL SYSTEM-PROGRAM
MABLE UNIT
Required minimum vertical clearance of an overhead service drop measured from the ground
over residential and comercial properties and driveways not subjected to truck traffic and over
600 volts to ground
Required minimum vertical clearance of an overhead service drop measured from the ground
over public streets, alleys, roads, parking areas subjected to truck traffic, driveways on other
than residential property, and other land traveresed by vehicular such as cultivated, grazing
forest and courtyards
BUSWAYS
120/240 VOLTS
System of voltage used for computing branch circuits and feeder load
WINDMILL
Natural energy source derived from force of wind acting on oblique blades
that radiates froma shaft attached to a dynamo to produce electricity
PANEL BOARD
Alternating current generated by the alternator where its wave rises to the
peak, sinks to zero, drops to the negative peak and rises again to zero a
number of times each second depending on the frequency for which the
machine is designed
2.2, 30, 8, 14
Minimum conductor size for for overhead service drop for copper wire or cable
UF
THW
Moisture and Heat Resistant Thermoplastic used for dry and wet locations
REFRACTION
38 mm (1 1/2")
WYE FITTING
6"
The minimum horizontal clearance of vent branch immediately above the flood
level rim of the fixture
THERMOSTAT
A device installed on electric water heater used to detect the working temperature to
to activate a switch
1 1/2"
3/8"
COUPLING
BATTERY OF FIXTURE
Interconnection of the same fixture in one soil or waste branch with one branch vent
COMMON VENT
A single vent that ventiliates multiple traps, in the case of back to back fixture
NUMBER OF FIXTURE
SOIL PIPE
Conveys a discharge of solid and liquid wastes closets with or without the
discharged from other fixture to the house drain
UTILITIES
102 mm (4")
In water distributon system which constantly rely its pressure from the main water pipe apply only
if the main fixture is supply continously with the flow rate and minimum required working pressure
PLUMBING SYSTEM
System of building which includes the water supply distribution pipes the
fixture and fixture traps, the soil waste and the vent pipes, the house drain
and the house sewer, the storm water drainage with their devices
64 mm (2 1/2")
Minimum size of wet standpipe for riser of more than 15 mts from source
6"
SIAMESE CONNECTIONS
BALL
Single level valve used in kichen sink, lavatory faucets or at shower valve
A suitable type of water pump for deep well 4" or 6' casing to deliver
35gpm against 450 ft. total develop height
ZEOLITE
CIRCUIT VENT
Vertical vent pipes take in front of the last fixture and connects to its soil
stack which acts as a vent
BUFFER
Rating index of an air conditioning system which rates the unit for the number
for BTU of heat moved per watt of electrical input energy
CIRCUIT BREAKER
ELECTRICAL PANEL BOX
PULL BOX
ELECTRONIC CONTROL PANEL
A passenger elevator safety device which protects the motor and its
electrical parts from over current
SAFETY SHOE
SAFETY GEAR
OUTSIDE DOOR LATCH
DOOR LOCK SWITCH
The elevator door components that detect the obstacle during the door closing and re opens
the door
AIR CURTAIN
Mechanical equipment install on top of the main doors used to retain cold in the interiors
WAIT INTERVAL
EVAPORATORS CANNOT BE
LOCATED AT CEILING
Major physical restriction does a split type air conditioner system have which restricts
its efficiency and performance
SAFETY SHOE
OUTSIDE DOOR LATCH
DOOR LOCK SWITCH
SAFETY GEAR
MAGNETIC BREAK
SAFETY SHOE
CIRCUIT BREAKER
GOVERNOR
Activate if the car travel faster than its travel speed, the power will turn off,
and grasp the rope to operate the safety gear
LIMIT SWITCH
EMERGENCY SWITCH
TRAVEL SWITCH
MOTOR CONTROL SWITCH
Device that open and closes the electric current in an elevator when it has reached the
designated end of travel course
Coupled with central air conditioning system, used to dehumidify and cool
the air stream injected into the conditioned space
CIRCUIT BREAKER
SERVICE RACEWAY
24 AMPERE
Maximum allowed ampere rating of one chord or plug utilization equipment connected in a 30
ampere branch circuit for lighting or utilization equipment
5.5 sq.mm
Minimum wire size in sq.mm type THW stranded copper conductor in raceway for a branch
circuit with 30 ampere rating
3500mm
Minimum vertical clearance of an overhead service drop measured from the ground, at the
electrical service entrance or above areas or sidewalks accesible only to pedestrian lanes,
measure from final grade line or other accesible surface only for service drop cabled together
with a grounded bare messenger wire and limited to 300 volts to ground
30 amperes
Minimum ampacity of feeder conductor with a load of more than two wire branch circuit supplied
by a 3-wire feeder but not exceed the computed branch circuit load
3.5 sq.m
Minimum wire size in sq.mm type TW copper conductor in raceway for a branch circuit with 20
ampere rating
45 Amperes
A branch circuit consisting of two or more grounded conductors having a potential difference
between them, and a grounded conductor having equal potential difference between it
A CLEARANCE OF NOT LESS THAN Pre requisite in use of split knob and tube wiring
76mm SHALL BE MAINTAINED
BETWEEN CONDUCTORS AND NOT
LESS THAN 26mm
PRESSURIZED WATER REACTOR
DEVICE
A unit of electrical system which is intended to carry but not utilize electrical energy
BUSWAYS
60 CYCLES
USE
SERVICE DROP
The overhead service conductor from the last pole or other aerial support
to and including the splices, if any connecting to te service entrance
conductors at the building
BALANCE LOADING
In a 240V, a three phase 3-wire service, branch cicuits are loaded and distributed to each
of the three phase with this objective to attain
CABLE TRAYS
Unit or assembly of unit sections and associated fittings forming a rigid structural system
used to support cables
30 amperes
Minimum branch circuit rating for household ranges and cooking appliance
POROUS ABSORBENT
HERTZ
MORE STUDIES
LABEL OF DRAWINGS
CATEGORIES OF ELEVATOR
ELEVATOR
ESCALATOR
PUMPS
VALVES
LIGHTNING ARRESTER
SERVICE DROPS
NBC
NPCP
FORMULA OF TL
CYCLE OF FAN COIL UNIT
Fitting in water closet in its order of sequence from the floor drain to the soil branch
2" P-TRAP 2x1/4 BEND 4x2 TEE
2" P-TRAP 2x1/16 BEND 4x2 TEE
2" P-TRAP 2x1/8 BEND 4x2 TEE
2" P-TRAP 2x1/4 BEND 2x1/8 BEND 4x2 WYE
Fitting installed at the branching tee from a horizontal soil branch to a horizonal waste branch
4 x 2 WYE AND 2" 1/8 BEND COMBINATION
4 x 4 TEE
4 x 2 TEE
4 x 4 WYE AND 4" 1/8 BEND COMBINATION
LOCATION 13
Fitting assembly joining the bare lavatory and the 2" tapped tee
1 1/4" DIAMETER STRAINER WITH POP UP VALVE
1 1/2" DIAMETER TAIL PIECE WITH POP UP VALVE
1 1/2" DIAMETER P-TRAP WITH POP UP VALVE
1 1/4" DIAMETER P-TRAP WITH POP UP VALVE
LOCATION 12
SUBMERSIBLE PUMP
jet,jack,reciprocating
PUMPS
A type of pump for driven well from 150 to 200 ft which work by a principle of venturi where
water of high pressure is pump into the well to draw water upwards through the return pipe
RECIPROCATING,TURBINE
CENTRIFUGAL, PISTON
A pump motor installed on the surface attached to a lift and push a rod to
activate a submerge piston
JET, SUBMERSIBLE
TURBINE, SUMP
A water pump for a 200ft driven well to deliver 10gpm against 200ft. It is
located at the surface
RECIPROCATING,TURBINE
CENTRIFUGAL, PISTON
A pump motor installed on the surface attached to a lift and push a rod to
activate a submerge piston
RECIPROCATING
CENTRIFUGAL, PISTON, TURBINE
A pump with an impeller enclose in a housing coupled with the pump motor
Its principle is to add a velocity to already flowing liquid
CENTRIFUGAL, SUBMERSIBLE
JET, TURBINE
A pump which delivers high water discharge with high water pressure drawn
from a shallow source like cistern, best suited as fire or transfer pump.
The motor is placed at the surface with shaft to turn the impellers below
A suitable type of water pump for deep well 4' or 6' casing to deliver
35gpm against 450 ft. total develop height
BUFFER
ELEVATOR
A safety device of a passenger elevator which reduces the collision shock of a car or
counterweight due to over travel beyond the lowest stop. It stops the car or counterweight safely
CIRCUIT BREAKER
ELECTRICAL PANEL BOX
PULL BOX
ELECTRONIC CONTROL PANEL
A passenger elevator safety device which protects the motor and its
electrical parts from over current
During elevator emergency to rescue passenger, this type of elevator is used to open the door
from the outside
SAFETY SHOE
SAFETY GEAR
OUTSIDE DOOR LATCH
DOOR LOCK SWITCH
The elevator door components that detect the obstacle during the door closing and re opens
the door
WAIT INTERVAL
SAFETY SHOE
OUTSIDE DOOR LATCH
DOOR LOCK SWITCH
SAFETY GEAR
MAGNETIC BREAK
SAFETY SHOE
CIRCUIT BREAKER
GOVERNOR
Activate if the car travel faster than its travel speed, the power will turn off,
and grasp the rope to operate the safety gear
LIMIT SWITCH
EMERGENCY SWITCH
TRAVEL SWITCH
MOTOR CONTROL SWITCH
Device that open and closes the electric current in an elevator when it has reached the
designated end of travel course
GOVERNOR
SAFETY GEAR
SAFETY SHOE
MAGNETIC BREAK
Safety device of a passenger elevator which activates if the car travels faster
than its rated speed by grasping the guide rail to stop the car safely
GOLDSTAR-KOREA
KOPPEL A.W.
DOVER
OTIS-U.S.
ESCALATOR
BOTTOM SPROCKET
GEARED HOIST
HELICAL GEARED MOTOR WITH
TRANSMISSION REDUCTION
CONTROL SYSTEM-PROGRAM
MABLE UNIT
AT THE ESCALATOR
MACHINE ROOM
ESCALATOR'S PART
1120;980;800;760
1150;1100;1000;900
Main power supply and wiring system for 110/220 volt line; which wiring diagram fits (drawing)
A CLEARANCE OF NOT LESS THAN Pre requisite in use of split knob and tube wiring
76mm SHALL BE MAINTAINED
BETWEEN CONDUCTORS AND NOT
LESS THAN 26mm
MULTI WIRE BRANCH CIRCUIT
550mm; 700mm
600mm; 850mm
An air terminal for lighting arrest is distanced at 7600mm. What must be the least height of the
air terminal above the building part being protected for disaster prevention
7500mm to 9000mm
5000mm to 6000mm
10000mm to 12000mm
6000mm to 7600mm
What is the maximum horizontal range between two or more air terminal for lightning
arrest for an effective disaster prevention in building
5500 mm
Required minimum vertical clearance of an overhead service drop measured from the ground
over residential and comercial properties and driveways not subjected to truck traffic
and over 600 volts to ground
Required minimum vertical clearance of an overhead service drop measured from the ground
over public streets, alleys, roads, parking areas subjected to truck traffic, driveways on other
than residential property, and other land traveresed by vehicular such as cultivated, grazing
forest and courtyards
3500mm
Minimum vertical clearance of an overhead service drop measured from the ground, at the
electrical service entrance or above areas or sidewalks accesible only to pedestrian lanes,
measure from final grade line or other accesible surface only for service drop cabled together
with a grounded bare messenger wire and limited to 300 volts to ground
24 amperes
Maximum allowed ampere rating of one chord or plug utilization equipment connected in a 30
ampere branch circuit for lighting or utilization equipment
Minimum ampacity of feeder conductor with a load of more than two wire branch circuit
supplied by a 3-wire feeder but not exceed the computed branch circuit load
Ampacity of an insulated copper conductor, based on ambient temperature of 30degrees
w/a 22 sq.m cross sectional area in size for USE
Ampacity of an insulated copper conductor, based on ambient temperature of 30degrees
w/a 8.0 sq.m cross sectional area in size for THW
Ampacity of an insulated copper conductor, based on ambient temperature of 30degrees
w/a 2.0 sq.m cross sectional area in size for TW
Minimum wire size in sq.mm type THW stranded copper conductor in raceway for a branch
circuit with 30 ampere rating
Minimum wire size in sq.mm type TW copper conductor in raceway for a branch circuit with
20 ampere rating
Minimum branch circuit rating for household ranges and cooking appliance
30 amperes
85 amperes
45 amperes
15 amperes
5.5 sq.mm
3.5 sq.m
30 amperes