0% found this document useful (0 votes)
136 views

CV & VT Pump Commissioning Format.

The document contains commissioning readings for a pump and motor, including current, voltage, RPM, temperature, and vibration readings taken hourly during a no load trial run. Motor details like serial number, KW rating, make, and pump details like serial number, type, head, discharge, and order number are listed. Sign off sections are at the bottom for various departments to confirm completion of commissioning trials.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views

CV & VT Pump Commissioning Format.

The document contains commissioning readings for a pump and motor, including current, voltage, RPM, temperature, and vibration readings taken hourly during a no load trial run. Motor details like serial number, KW rating, make, and pump details like serial number, type, head, discharge, and order number are listed. Sign off sections are at the bottom for various departments to confirm completion of commissioning trials.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 8

VT PUMP COMMISSIONING READINGS

Name of Client:-

RKM POWER GEN PVT LTD

Date
Motor Details

Pump Details
Pump Serial No
Pump Type
Head
Discharge
Order No.
Pump starting current
Sump Level
Forebay Level
Pump starting time
Pump trip time
Sr
Time
No

Motor Serial No
Motor KW
Motor Make
RPM
Supply
Current
Frame Size
Frequency
PF Value
Water level to Discharge pressure gauge height

Current
R

Voltage

RPM

Dis.Pres. Discharge

Brg. Temp.

Pump DE

Motor Winding Temp.

Vibration Readings

Motor NDE Motor DE


Oil temp Metal Temp

Motor NDE

Motor DE

Pump DE

1
2
3
4
5
6
7
8

M/S KBL

MECH Erection dept.

Electrical Erection dept.

O &M dept.

C & I dept.

Quality Dept.

Frequency

CV PUMP COMMISSIONING READINGS


Name of Client

Date

Pump Details
Pump Serial No
Pump Type
Head
Discharge
Order No.
Pump starting current
Sump Level
Pump starting time
Pump trip time
Forebay Level

Motor Details
Motor Serial No.
Motor KW
Motor Make
RPM
Supply
Current
Frame Size
Frequency
PF Value
Discharge pressure gauge to water level height

Sr.
No.

Time

Current

Voltage

RPM

Dis.Pres Discharge

Brg. Temp.
Motor
NDE

Motor
DE

Pump DE
Oil
Metal
temp
Temp
.

Motor Winding Temp.


1

Vibration Readings
6

Motor NDE Motor DE Pump DE

1
2
3
4
5
6
7
8

M/S KBL

MECH Erection dept.

Electrical Erection dept.

O &M dept.

C & I dept.

Quality Dept.

Frequency

INGS

MOTOR NO LOAD TRIAL RUN


Name of Client

RKM POWER GEN PVT LTD

Pump Details
Pump Serial No
Pump Type
Head
Discharge
Order No.
Pump starting current
Pump starting time
Pump trip time

VERTICAL TURBINE

Sr.
No.

Time

1 05.00 A.M
2 6.00 A.M
3 7.00 A.M
4 8.00 A.M
5 9.00 A.M
6 10.00 A.M
7 11.00 A.M
8 12.00 A.M

M/S KBL

BHQ92,1STAGE
22 M
16920 M3/HR
C07711A001
244.9 A
5.00 AM
1.00 PM
Current
Y

Voltage

RPM

Brg. Temp.
Motor NDE Motor DE

32.17

34.33

31.36

11.21

492

28

28

32.68

34.59

33.54

11.25

492

30

30

35

36.37

33.68

11.31

492

32

34

33.14

34.25

34.23

11.29

492

34

38

31.59

36.5

34.48

11.33

492

36.5

42

35.75

35.75

33.16

11.35

492

38

44

33.69

35.68

34.67

11.37

492

38

46

32.99

36.26

35.23

11.34

492

38.5

46.5

MECH Erection dept.

Electrical Erection dept.

Commissioning dept

AD TRIAL RUN READINGS

LTD

Date

9/11/2014

Motor Details
Motor Serial No.
Motor KW
Motor Make
RPM
Supply
Current
Frame Size
PF Value

Squirrel Cage,Ac induction motor


1350 kw
Hyosung
490
11 kv
33.59
0.84

Motor Winding Temp.


1

Commissioning dept

Vibration Readings
5

C & I dept.

Motor NDE Motor DE


1.10

1.20

1.00

1.20

1.10

1.10

1.00

1.10

0.90

1.10

0.90

1.00

1.00

1.10

1.10

1.10

Quality Dept.

Frequency

MOTOR NO LOAD TRIAL RU


Name of Client

RKM POWER GEN PVT LTD

Pump Details
Pump Serial No
Pump Type
Head
Discharge
Order No.
Pump starting current
Pump starting time
Pump trip time

Kirloskar brothers limited


BHRc7-5 stage
SWL
269 m
1023.34 m3/hr
C07711A001
301 Amp
9.20 pm
6.00am

Sr. No.

Current
Y

Time
R
1
2
3
4
5
6
7
8

9.20 p.m
10.20 p.m
11.20 p.m
0.20 a.m
1.20 a.m
2.20 a.m
3.20 a.m
4.20 a.m

M/S KBL

11.24
11.98
11.58
11.42
11.93
11.35
11.61
11.69

13.26
13.64
13.27
13.34
13.34
13.45
13.59
13.31

MECH Erection dept.

Voltage

RPM

11.26
11.09
11.23
11.48
11.55
11.23
11.43
11.31

988
988
988
988
988
988
988
988

B
12.66
12.54
12.18
12.27
11.99
12.19
12.2
12.16

Brg. Temp.
Motor NDE Motor DE

Electrical Erection dept.

29
34
38
40
44
50
51
51

28
32
34
35
35
36
36
36

Commissioning

AD TRIAL RUN READINGS

LTD

Date

7/5/2014

Motor Details
Motor Serial No.
Motor KW
Motor Make
RPM
Supply
Current
Frame Size
PF Value

VSTC
LA80355705
1150 KW
HYOSUNG
988
11KV
70.6A
560F
0.9

Motor Winding Temp.


1

Commissioning dept

Vibration Readings Frequency


5

C & I dept.

Motor NDE Motor DE


1.1
1.6
1.3
1.3
1.1
1.2
1
1.3
1.2
1.2
1.4
1.4
1.4
1.4
1.3
1.4

Quality Dept.